1
|
Chai C, Sun Q, Guo X, Yang J, Xie H, Ma J, Wei H, Yu J. Safety and efficacy of catheter ablation of para-Hisian accessory pathway via a direct superior vena cava approach: A multicenter study. Clin Cardiol 2024; 47:e24180. [PMID: 37889106 PMCID: PMC10766120 DOI: 10.1002/clc.24180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 10/10/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023] Open
Abstract
BACKGROUND Radiofrequency (RF) catheter ablation of para-Hisian accessory pathways (APs) can be challenging due to proximity to the conduction system. METHODS A total of 30 consecutive patients with para-Hisian AP were enrolled for ablation in three centers, 12 (40%) of whom had previously failed attempted ablation from the inferior vena cava (IVC) approach. Ablation was preferentially performed using a superior approach from the superior vena cava (SVC) in all patients. RESULTS The para-Hisian AP was eliminated from the SVC approach in 28 of 30 (93.3%) patients. In the remaining two patients, additional ablation from IVC was required to successfully eliminate the AP. There were two patients experienced reversible complete atrial-ventricular block and PR prolongation during the first RF application. Long-term freedom from recurrent arrhythmia was achieved in 29 (96.7%) patients over a mean follow-up duration of 15.6 ± 4.6 months. CONCLUSION Catheter ablation of para-Hisian AP from above using a direct SVC approach is both safe and effective, and should be considered especially in patients who have failed conventional ablation attempts from IVC approach.
Collapse
Affiliation(s)
- Chanjuan Chai
- Department of CardiologyThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Qi Sun
- State Key Laboratory of Cardiovascular DiseaseArrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical CollegeBeijingChina
| | - Xiao‐Gang Guo
- State Key Laboratory of Cardiovascular DiseaseArrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical CollegeBeijingChina
| | - Jian‐Du Yang
- State Key Laboratory of Cardiovascular DiseaseArrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical CollegeBeijingChina
| | - Hai‐Yang Xie
- Departent of CardiologySun Yat‐Sen Memorial HospitalSun Yat‐Sen UniversityGuangzhouChina
| | - Jian Ma
- State Key Laboratory of Cardiovascular DiseaseArrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical CollegeBeijingChina
| | - Hui‐Qiang Wei
- Department of CardiologyGuangdong Cardiovascular Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences)Southern Medical UniversityGuangzhouChina
| | - Jie Yu
- Department of CardiologyYantaishan HospitalYantaiChina
| |
Collapse
|
2
|
Lebloa M, Pascale P. Preprocedural Discrimination of Posteroseptal Accessory Pathways Ablated from the Right Endocardium from Those Requiring a Left-sided or Epicardial Coronary Venous Approach. Arrhythm Electrophysiol Rev 2022; 11:e07. [PMID: 35734142 PMCID: PMC9194913 DOI: 10.15420/aer.2021.55] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 03/09/2022] [Indexed: 11/04/2022] Open
Abstract
The success of radiofrequency catheter ablation of the accessory pathway (AP) depends on the accurate localisation of the bypass tract. In that respect, posteroseptal or inferior paraseptal APs often pose a diagnostic challenge because of the complex anatomy at the crux of the four cardiac chambers. Considering the differences in procedure risks and success rate depending on the need for a left-sided approach or a coronary sinus ablation, an accurate anticipation of the precise location of inferior paraseptal APs is critical to inform the consent process and guide the initial mapping strategy. Here, the preprocedural clues to discriminate APs that can be ablated from the right atrium, from those requiring a left-sided or epicardial coronary venous approach, are reviewed. Both manifest and concealed APs will be considered and, following the diagnostic process made by the operator before interpretation of the intra-cardiac signals, each of the following aspects will be addressed: clinical context and initial probability; and 12-lead ECG analysis during baseline ECG with manifest AP, maximal preexcitation, and orthodromic reciprocating tachycardia.
Collapse
Affiliation(s)
- Mathieu Lebloa
- Arrhythmia Unit, Cardiovascular Department, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
| | - Patrizio Pascale
- Arrhythmia Unit, Cardiovascular Department, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
3
|
Radiofrequency catheter ablation of patients with permanent junctional reciprocating tachycardia and long-term follow-up results. J Interv Card Electrophysiol 2021; 63:461-469. [PMID: 34476675 DOI: 10.1007/s10840-021-01057-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Accepted: 08/23/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Permanent junctional reciprocating tachycardia (PJRT) is an infrequent form of atrioventricular re-entrant tachycardia. We report the clinical and electrophysiological properties of PJRT and outcomes of radiofrequency catheter ablation (RCA) in a large group of patients. METHODS We included 62 patients with the diagnosis of PJRT. Radiofrequency catheter ablation was performed in all. RESULTS Location of accessory pathway was right posteroseptal in 37 (59,7%) cases, right midseptal in 3 (4,8%), left posterior in 7 (11,3%), left lateral in 5 (8,1%), left posterolateral in 3 (4,8%), left anterolateral in 2 (3,2%), left posteroseptal in 2 (3,2%), middle cardiac vein in 2 (3,2%), and left coronary cusp in 1 (1,6%). Single procedure success rate was 90.3%. None of patients had recurrence during follow-up after repeat ablations. Overall long-term success rate was 98.4%. Left ventricular systolic function recovered in all patients with tachycardia-induced cardiomyopathy (TIC). CONCLUSION Retrograde decremental accessory pathways are mainly located in posteroseptal region. Radiofrequency catheter ablation is a safe and effective approach in patients with PJRT.
Collapse
|
4
|
Mechanical suppression of premature ventricular complexes during catheter ablation procedures. Indian Pacing Electrophysiol J 2020; 21:29-35. [PMID: 33221527 PMCID: PMC7854373 DOI: 10.1016/j.ipej.2020.11.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 10/23/2020] [Accepted: 11/05/2020] [Indexed: 11/22/2022] Open
Abstract
Introduction Mechanical suppression of premature ventricular complexes (PVCs) is not a well-known observation. We retrospectively reviewed this phenomenon in the Ventricular Arrhythmia (VA) ablation procedures performed at Richard L. Roudebush Veterans Health Administration (VHA) center. Methods Data from 40 consecutive patients who underwent VA ablation at VHA, Indianapolis, IN, with 44 VA was included in the study. Demographic and electrophysiological parameter data was collected. Results Overall the mean age of the population was 64 ± 11 years. The phenomenon of mechanical suppression was seen in 11 PVCs. The mean age was 59 ± 15 years in the group in which mechanical suppression was seen. Of the 11 cases, the site of earliest activation was seen in the coronary sinus in 8 and in the pulmonary artery in 3. In one case catheter ablation was not performed because of proximity to the left coronary artery system. However, sustained pressure at the site with earliest electrograms (−35 ms) and 95% pacematch resulted in long-term suppression of PVCs. In the cases in which mechanical suppression was seen, there was a statistically significant reduction in PVC burden compared to pre ablation PVC load (1.1% ± 1.50% (post ablation) versus 24.04% ± 13.07% (pre ablation) versus p < 0.05). In all the 11 cases the site of mechanical suppression was also the site with earliest electrograms. Conclusion This case series illustrates phenomenon of mechanical suppression of PVCs as an indication for good site for successful ablation in unique veteran patient population.
Collapse
|
5
|
Wieczorek M, Tajtaraghi S, Hoeltgen R. A subvalvular catheter approach for radiofrequency ablation of right-sided accessory pathways. J Interv Card Electrophysiol 2019; 56:29-36. [PMID: 31385112 DOI: 10.1007/s10840-019-00597-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Accepted: 07/16/2019] [Indexed: 10/26/2022]
Abstract
BACKGROUND Conventional catheter ablation of right-sided accessory pathways (RAPs) can be challenging. OBJECTIVE To determine if a subvalvular catheter approach for RAPs targeting the ventricular insertion site, as on the left side, can improve catheter stability and tissue contact and thus increase acute and chronic ablation success rates. METHODS AND RESULTS We retrospectively compared 22 patients (pts) with conventional catheter ablation of RAPs (group 1) with 9 consecutive pts (group 2) undergoing catheter ablation of a RAP using a subvalvular catheter approach targeting the ventricular site of AP. Ablation failed in 2/22 group 1 vs 0/9 group 2 pts (ns) and recurrences of AP conduction were registered in 4/19 group 1 vs 1/9 group 2 pts (ns) during follow-up. Significant shorter values were found in group 2 pts compared with group 1 for number of RF applications (3.6 ± 1.6 vs 8.2 ± 4.3), AP block time (6.2 ± 2.4 vs 9.2 ± 3.9 min), fluoroscopy time (17.2 ± 6.9 vs 25.6 ± 10.3 min), and procedure time (70.8 ± 23.9 vs 138 ± 44.4 min). There were no procedure related complications. CONCLUSION Catheter ablation of RAPs using a subvalvular approach seems as effective and safe compared with conventional ablation but with reduced procedure time and radiation exposure and might be at least considered an alternative after failed conventional catheter ablation of RAPs.
Collapse
Affiliation(s)
- Marcus Wieczorek
- School of Medicine, Witten/Herdecke University, Witten, North Rhine-Westphalia, Germany. .,Department of Cardiology and Electrophysiology, St. Agnes-Hospital Bocholt, Barloer Weg 125, 46397, Bocholt, Germany.
| | - Sharam Tajtaraghi
- Department of Cardiology and Electrophysiology, St. Agnes-Hospital Bocholt, Barloer Weg 125, 46397, Bocholt, Germany
| | - Reinhard Hoeltgen
- Department of Cardiology and Electrophysiology, St. Agnes-Hospital Bocholt, Barloer Weg 125, 46397, Bocholt, Germany
| |
Collapse
|
6
|
de Alencar Neto JN, Nagahama MV, de Moraes SRR, Magliari RT, Cirenza C, de Paola AAV. Radiofrequency ablation of a middle cardiac vein inserted accessory pathway resulting in posterolateral coronary artery occlusion: A case report. Indian Pacing Electrophysiol J 2018; 19:34-38. [PMID: 30414465 PMCID: PMC6354235 DOI: 10.1016/j.ipej.2018.11.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 10/21/2018] [Accepted: 11/05/2018] [Indexed: 11/17/2022] Open
Abstract
Introduction Posteroseptal accessory pathways account for 34.5% of the total. Of these, 36% are located within the coronary sinus (CS). Its ablation requires technical alternatives to avoid damage to surrounding tissues, especially branches of the right coronary artery. Case report A 22-year-old man was referred for re-do ablation of an accessory left septal-septal (PSE) pathway. Inside the CS, a precocity of 25 ms was found in the region of the median cardiac vein (VCM) (Fig. 2, panel A). Radiofrequency (RF) was administered with a non-irrigated bidirectional catheter within this vessel with resolution of the pre-excitation after 5 seconds. Immediately after, the patient presented chest pain and revealed a ST segment elevation of 1 mm in the inferior leads of ECG. Coronary angiography showed occlusion of the middle third of the posterior ventricular branch of the right coronary artery, with no signs of thrombus or dissection. Arterial angioplasty was performed with a bare metal stent, followed by TIMI III distal flow. Retrograde aortic mapping was performed and a precocity of 20 ms was found in the PSE region. The RF was applied followed by loss of pre-excitation after 1.5 seconds of application. Conclusion This case demonstrates the risks involving delivering radiofrequency within the coronary sinus. We discuss some strategy that could help electrophysiologists in similar cases.
Collapse
Affiliation(s)
| | - Marina Vieira Nagahama
- Universidade Federal de São Paulo, Escola Paulista de Medicina, Hospital São Paulo, São Paulo, Brazil
| | | | - Rafael Thiesen Magliari
- Universidade Federal de São Paulo, Escola Paulista de Medicina, Hospital São Paulo, São Paulo, Brazil
| | - Claudio Cirenza
- Universidade Federal de São Paulo, Escola Paulista de Medicina, Hospital São Paulo, São Paulo, Brazil
| | | |
Collapse
|
7
|
[Three-dimensional mapping : Special aspects and new features of CARTO®]. Herzschrittmacherther Elektrophysiol 2018; 29:259-263. [PMID: 30076446 DOI: 10.1007/s00399-018-0583-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 07/11/2018] [Indexed: 02/07/2023]
Abstract
The precise target location for radiofrequency energy delivery was initially determined through electrophysiological signals and with the help of fluoroscopy. The introduction of the 3D mapping system CARTO® (Biosense Webster Inc., Diamond Bar, CA, USA) in recent years for radiofrequency ablation of arrhythmias has provided new therapeutic options. These improvements have led to reduced procedural and fluoroscopic times. The introduction of new software and technology has also improved clinical outcome and helped to understand the substrate of complex arrhythmias. This article provides an overview of the development of the CARTO® system and presents new features of the system.
Collapse
|
8
|
Yang J, Yang G, Chen H, Ju W, Yang B, Zhang F, Jin Y, Cao J, Qian L, Chen M. An alternative under-valve approach to ablate right-sided accessory pathways. Heart Rhythm 2018; 16:51-56. [PMID: 30031200 DOI: 10.1016/j.hrthm.2018.07.022] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Indexed: 11/16/2022]
Abstract
BACKGROUND Right-sided accessory pathway (RAP) ablation is sometimes challenging. OBJECTIVE Our study aimed to demonstrate an alternative ablation approach to RAPs under the tricuspid valve, especially when the conventional ablation attempts at the atrial side failed. METHODS Twelve patients with RAPs were enrolled, 8 of whom had previously failed ablation. With the help of a long sheath, the under-valve approach was attempted in 3 patients during tachycardia, in 2 patients during ventricular pacing, and in 7 patients during sinus rhythm. Three-dimensional electroanatomic mapping was performed in 3 patients during their repeat procedures. RESULTS The acute outcomes of the procedures in all patients were successful. Patients were free of tachycardia or recurrence of accessory pathway conduction during a median follow-up of 12.5 months (range 7-45 months). No complications were found during the procedure or follow-up period. CONCLUSION Radiofrequency ablation under the tricuspid valve to eliminate RAPs is feasible because of its stable contact and the accurate ablation of the ventricular insertion site. It provides an alternative approach to tough RAP ablation.
Collapse
Affiliation(s)
- Jun Yang
- Cardiovascular Medical Center of Jiangsu, Women and Children Branch Hospital, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China; Department of Cardiology, The Affiliated Wuxi No.2 People's Hospital of Nanjing Medical University, Wuxi, China
| | - Gang Yang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Hongwu Chen
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Weizhu Ju
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Bing Yang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Fengxiang Zhang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Yan Jin
- Department of Cardiology, The Affiliated Wuxi No.2 People's Hospital of Nanjing Medical University, Wuxi, China
| | - Jianing Cao
- Department of Cardiology, The Affiliated Wuxi No.2 People's Hospital of Nanjing Medical University, Wuxi, China
| | - Lingmei Qian
- Cardiovascular Medical Center of Jiangsu, Women and Children Branch Hospital, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
| | - Minglong Chen
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| |
Collapse
|
9
|
Liu Q, Shehata M, Lan DZ, Ehdaie A, Cingolani E, Chugh SS, Fu G, Jiang C, Wang X. Accurate localization and catheter ablation of superoparaseptal accessory pathways. Heart Rhythm 2018; 15:688-695. [DOI: 10.1016/j.hrthm.2017.12.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Indexed: 11/25/2022]
|
10
|
Brembilla-Perrot B, Huttin O, Olivier A, Sellal JM, Villemin T, Manenti V, Moulin-Zinsch A, Marçon F, Simon G, Andronache M, Beurrier D, de Chillou C, Girerd N. Age-related location of manifest accessory pathway and clinical consequences. Indian Pacing Electrophysiol J 2016; 15:227-35. [PMID: 27134439 PMCID: PMC4834439 DOI: 10.1016/j.ipej.2016.02.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Accessory pathway (AP) ablation is not always easy. Our purpose was to assess the age-related prevalence of AP location, electrophysiological and prognostic data according to this location. METHODS Electrophysiologic study (EPS) was performed in 994 patients for a pre-excitation syndrome. AP location was determined on a 12 lead ECG during atrial pacing at maximal preexcitation and confirmed at intracardiac EPS in 494 patients. RESULTS AP location was classified as anteroseptal (AS)(96), right lateral (RL)(54), posteroseptal (PS)(459), left lateral (LL)(363), nodoventricular (NV)(22). Patients with ASAP or RLAP were younger than patients with another AP location. Poorly-tolerated arrhythmias were more frequent in patients with LLAP than in other patients (0.009 for ASAP, 0.0037 for RLAP, <0.0001 for PSAP). Maximal rate conducted over AP was significantly slower in patients with ASAP and RLAP than in other patients. Malignant forms at EPS were more frequent in patients with LLAP than in patients with ASAP (0.002) or PSAP (0.001). Similar data were noted when AP location was confirmed at intracardiac EPS. Among untreated patients, poorly-tolerated arrhythmia occurred in patients with LLAP (3) or PSAP (6). Failures of ablation were more frequent for AS or RL AP than for LL or PS AP. CONCLUSIONS AS and RLAP location in pre-excitation syndrome was more frequent in young patients. Maximal rate conducted over AP was lower than in other locations. Absence of poorly-tolerated arrhythmias during follow-up and higher risk of ablation failure should be taken into account for indications of AP ablation in children with few symptoms.
Collapse
Affiliation(s)
| | - Olivier Huttin
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Arnaud Olivier
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Jean Marc Sellal
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Thibaut Villemin
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Vladimir Manenti
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Anne Moulin-Zinsch
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - François Marçon
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Gauthier Simon
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Marius Andronache
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | - Daniel Beurrier
- Adult and Pediatric Cardiology, CHU de Brabois, Vandoeuvre Les Nancy, France
| | | | - Nicolas Girerd
- INSERM, Centre d'Investigations Cliniques 9501, Université de Lorraine, Institut Lorrain du cœur et des vaisseaux, CHU de Nancy, Nancy, France
| |
Collapse
|
11
|
SUN HUAN, OH YENA, YAN MINGZHOU, YU BO. 3D Is It a Better Choice for All, or for Some? J Cardiovasc Electrophysiol 2015; 26:E9. [PMID: 25952964 DOI: 10.1111/jce.12708] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- HUAN SUN
- Cardiology Department; China-Japan Union Hospital of Jilin University; Changchun China
| | - YENA OH
- Departments of Physiology and Medicine; University of Toronto; Toronto Canada
| | - MINGZHOU YAN
- Cardiology Department; China-Japan Union Hospital of Jilin University; Changchun China
| | - BO YU
- Cardiology Department; China-Japan Union Hospital of Jilin University; Changchun China
| |
Collapse
|
12
|
Green HN, Crockett SD, Martyshkin DV, Singh KP, Grizzle WE, Rosenthal EL, Mirov SB. A histological evaluation and in vivo assessment of intratumoral near infrared photothermal nanotherapy-induced tumor regression. Int J Nanomedicine 2014; 9:5093-102. [PMID: 25395847 PMCID: PMC4227627 DOI: 10.2147/ijn.s60648] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
PURPOSE Nanoparticle (NP)-enabled near infrared (NIR) photothermal therapy has realized limited success in in vivo studies as a potential localized cancer therapy. This is primarily due to a lack of successful methods that can prevent NP uptake by the reticuloendothelial system, especially the liver and kidney, and deliver sufficient quantities of intravenously injected NPs to the tumor site. Histological evaluation of photothermal therapy-induced tumor regression is also neglected in the current literature. This report demonstrates and histologically evaluates the in vivo potential of NIR photothermal therapy by circumventing the challenges of intravenous NP delivery and tumor targeting found in other photothermal therapy studies. METHODS Subcutaneous Cal 27 squamous cell carcinoma xenografts received photothermal nanotherapy treatments, radial injections of polyethylene glycol (PEG)-ylated gold nanorods and one NIR 785 nm laser irradiation for 10 minutes at 9.5 W/cm(2). Tumor response was measured for 10-15 days, gross changes in tumor size were evaluated, and the remaining tumors or scar tissues were excised and histologically analyzed. RESULTS The single treatment of intratumoral nanorod injections followed by a 10 minute NIR laser treatment also known as photothermal nanotherapy, resulted in ~100% tumor regression in ~90% of treated tumors, which was statistically significant in a comparison to the average of all three control groups over time (P<0.01). CONCLUSION Photothermal nanotherapy, or intratumoral nanorod injections followed by NIR laser irradiation of tumors and tumor margins, demonstrate the potential of NIR photothermal therapy as a viable localized treatment approach for primary and early stage tumors, and prevents NP uptake by the reticuloendothelial system.
Collapse
Affiliation(s)
- Hadiyah N Green
- Department of Physics, Center for Optical Sensors and Spectroscopies, The University of Alabama at Birmingham, Birmingham, AL, USA
- Comprehensive Cancer Center, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Stephanie D Crockett
- Department of Pediatrics, Division of Neonatology, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Dmitry V Martyshkin
- Department of Physics, Center for Optical Sensors and Spectroscopies, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Karan P Singh
- Comprehensive Cancer Center, The University of Alabama at Birmingham, Birmingham, AL, USA
- Department of Medicine, Division of Preventive Medicine, Biostatistics and Bioinformatics Shared Facility, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - William E Grizzle
- Comprehensive Cancer Center, The University of Alabama at Birmingham, Birmingham, AL, USA
- Department of Pathology, Division of Otolaryngology, Head and Neck Surgery, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Eben L Rosenthal
- Comprehensive Cancer Center, The University of Alabama at Birmingham, Birmingham, AL, USA
- Department of Surgery, Division of Otolaryngology, Head and Neck Surgery, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Sergey B Mirov
- Department of Physics, Center for Optical Sensors and Spectroscopies, The University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
13
|
KARADENIZ CEM, AKDENIZ CELAL, TURAN OZLEM, TUZCU VOLKAN. Cryoablation of Septal Accessory Pathways in Children: Midterm Results. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2014; 37:1095-9. [DOI: 10.1111/pace.12442] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2014] [Revised: 04/07/2014] [Accepted: 04/27/2014] [Indexed: 11/29/2022]
Affiliation(s)
- CEM KARADENIZ
- Pediatric and Genetic Arrhythmia Center; Istanbul Medipol University Hospital; Istanbul Turkey
| | - CELAL AKDENIZ
- Pediatric and Genetic Arrhythmia Center; Istanbul Medipol University Hospital; Istanbul Turkey
| | - OZLEM TURAN
- Pediatric and Genetic Arrhythmia Center; Istanbul Medipol University Hospital; Istanbul Turkey
| | - VOLKAN TUZCU
- Pediatric and Genetic Arrhythmia Center; Istanbul Medipol University Hospital; Istanbul Turkey
| |
Collapse
|
14
|
Ergul Y, Tola HT, Kiplapinar N, Akdeniz C, Saygi M, Tuzcu V. Cryoablation of anteroseptal accessory pathways in children with limited fluoroscopy exposure. Pediatr Cardiol 2013; 34:802-8. [PMID: 23052673 DOI: 10.1007/s00246-012-0536-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2012] [Accepted: 09/14/2012] [Indexed: 11/29/2022]
Abstract
Due to its safety profile, cryoablation is used increasingly in pediatric patients, especially for septal arrhythmia substrates. Recent advances in electroanatomical-mapping technologies have resulted in a decrease or complete elimination of fluoroscopy exposure during catheter ablation procedures. The aim of this study was to assess the efficacy and safety of cryoablation of anteroseptal accessory pathways (APs) using electroanatomical-mapping system guidance with limited fluoroscopy exposure. A total of 24 patients underwent cryoablation of anteroseptal APs between July 2010 and April 2012. Cryomapping was performed with a 6 mm-tip catheter at -30 °C before the lesions were delivered. An 8 mm-tip catheter was used in one patient. The EnSite system (St. Jude Medical, St Paul, MN) was used in all procedures. The mean age was 11.9 ± 4.3 years. Acute success rate was 95.8 % (23 of 24). The mean procedure and cryoablation durations were 168 ± 58 min and 1,463 ± 525 s, respectively. Limited fluoroscopy was used only in 7 patients, and the mean fluoroscopy time was 1.7 ± 1.8 min (range 0.1-4 min) in these patients. Recurrence was noted in 2 patients (8.7 %) who underwent a second successful cryoablation procedure. The patient who underwent a failed attempt during the first procedure was successfully treated with a repeat procedure. The resultant long-term success rate was 100 % at a mean follow-up period of 14.2 ± 7.7 months. There were no complications except for transient atrioventricular block in one patient. Cryoablation of anteroseptal APs can be performed effectively and safely in children using a limited fluoroscopic approach with the help of electroanatomical-mapping systems.
Collapse
Affiliation(s)
- Yakup Ergul
- Mehmet Akif Ersoy Cardiovascular Research and Training Hospital, Istanbul, Turkey
| | | | | | | | | | | |
Collapse
|
15
|
Chen ML, Yang B, Ju WZ, Chen HW, Chen C, Hou XF, Zhang F, Cui JY, Zhang CH, Shan QJ, Zou JG, Sun JP, Xi YT, Cheng J, Cao KJ. Right-sided free wall accessory pathway refractory to conventional catheter ablation: lessons from 3-dimensional electroanatomic mapping. J Cardiovasc Electrophysiol 2011; 21:1317-24. [PMID: 20653815 DOI: 10.1111/j.1540-8167.2010.01857.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
INTRODUCTION the aim of this study was to delineate the electroanatomic substrates of right-sided free wall (RFW) accessory pathways (APs) that were refractory to conventional catheter ablation utilizing 3-dimensional (3-D) mapping. METHODS AND RESULTS eleven patients with RFW APs that failed initial conventional catheter ablation(s) by a mean of 1.9 ± 0.5 attempts were enrolled in the study. Electroanatomic mapping of the right atrium was performed during orthodromic reciprocating tachycardia in 3 patients and right ventricular pacing in 8 patients. The earliest atrial activation site, which represented the atrial insertion of the AP, was separated from the tricuspid annulus by an average of 14.3 ± 3.9 mm, and the local activation time was 27.8 ± 17.0 ms earlier than that of the corresponding annular point. One patient exhibited an AP with wide branching on the atrial side. RF ablation with an irrigated catheter successfully interrupted AP conduction in all patients without complications. CONCLUSIONS RFW APs resistant to conventional catheter ablation might be due to unique anatomic AP features such as more epicardial course at the annulus level with atrial insertion distant from the tricuspid annulus. Electroanatomic mapping is helpful to accurately localize the atrial insertion sites of these APs and facilitates catheter ablation.
Collapse
Affiliation(s)
- Ming Long Chen
- Department of Cardiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Santilli RA, Critelli M, Baron Toaldo M. ECG of the Month. Accessory atrioventricular pathway-mediated tachycardia. J Am Vet Med Assoc 2010; 237:1142-4. [PMID: 21073383 DOI: 10.2460/javma.237.10.1142] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- Roberto A Santilli
- Clinica Veterinaria Malpensa, Viale Marconi 27, 21017 Samarate, Varese, Italy.
| | | | | |
Collapse
|
17
|
Bastani H, Insulander P, Schwieler J, Tabrizi F, Braunschweig F, Kenneback G, Drca N, Jensen-Urstad M. Cryoablation of superoparaseptal and septal accessory pathways: a single centre experience. Europace 2010; 12:972-7. [DOI: 10.1093/europace/euq079] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
18
|
Rostock T, Steven D, Lutomsky B, Servatius H, Drewitz I, Klemm H, Müllerleile K, Ventura R, Meinertz T, Willems S. Atrial fibrillation begets atrial fibrillation in the pulmonary veins on the impact of atrial fibrillation on the electrophysiological properties of the pulmonary veins in humans. J Am Coll Cardiol 2008; 51:2153-60. [PMID: 18510963 DOI: 10.1016/j.jacc.2008.02.059] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2008] [Revised: 02/04/2008] [Accepted: 02/11/2008] [Indexed: 10/22/2022]
Abstract
OBJECTIVES Our purpose was to investigate the impact of short-lasting atrial fibrillation (AF) on the electrophysiological properties of the atria and pulmonary veins (PVs) in patients devoid of AF. BACKGROUND The presence of AF is associated with electrical remodeling processes that promote a substrate for arrhythmia maintenance in the atria, which has been termed "AF begets AF." However, it is unclear whether those electrical alterations also occur in the PVs. METHODS Thirty-five patients with a left-sided accessory pathway and without a prior history of AF were included. After successful ablation, the effective refractory periods (ERPs) and conduction times of the right atrium (RA), left atrium (LA), and the PVs were determined. Afterwards, AF was induced and maintained for a period of 15 min. Thereafter, the stimulation protocol was repeated. RESULTS At baseline, the PVs had significantly longer ERPs than the atria. After exposure to AF, the ERPs of both the atria and the PVs decreased significantly. The ERPs of the PVs, however, decreased by a significantly greater extent than the ERPs of the atria (PVs: 248 +/- 27 ms vs. 211 +/- 40 ms, p < 0.001; LA: 233 +/- 23 ms vs. 214 +/- 20 ms, p = 0.004; RA: 226 +/- 29 ms vs. 188 +/- 20 ms; p = 0.003). After AF exposure, the PVs demonstrated a significant conduction slowing whereas the atria did not (PVs: 125 +/- 33 ms vs. 159 +/- 37 ms, p < 0.001; LA: 129 +/- 26 ms vs. 130 +/- 24 ms, p = NS; RA: 192 +/- 36 ms vs. 196 +/- 32 ms, p = NS). Finally, AF was more frequently induced after the presence of AF, particularly by pacing in the PVs (14% vs. 49%, p = 0.001). CONCLUSIONS New-onset, short-lasting AF creates electrical characteristics similar to those of patients with AF. However, these alterations are pronounced in the PVs compared with the atria, indicating that "AF begets AF in the PVs" (Electrophysiological Properties of the Pulmonary Veins; NCT00530608).
Collapse
Affiliation(s)
- Thomas Rostock
- University Hospital Eppendorf, Department of Cardiology, Hamburg, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Santilli R, Perego M, Crosara S, Gardini F, Bellino C, Moretti P, Spadacini G. Utility of 12-Lead Electrocardiogram for Differentiating Paroxysmal Supraventricular Tachycardias in Dogs. J Vet Intern Med 2008; 22:915-23. [DOI: 10.1111/j.1939-1676.2008.0127.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
20
|
Huttin O, Brembilla-Perrot B. [Relationships between age and accessory pathway location in Wolff-Parkinson-White syndrome]. Ann Cardiol Angeiol (Paris) 2008; 57:225-30. [PMID: 18550025 DOI: 10.1016/j.ancard.2008.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2007] [Accepted: 03/25/2008] [Indexed: 11/19/2022]
Abstract
BACKGROUND Radiofrequency ablation of atrioventricular accessory pathway (AP) which is currently used, remains associated with a risk of complete AV block in the case of anteroseptal (AS) location and its indication remains debatable. The purpose of the study was to evaluate the frequency of AS location in Wolff-Parkinson-White syndrome (WPW) and the clinical and electrophysiological data of these patients. METHODS Electrophysiologic study (EPS) was performed in 503 pts aged from six to 85 years (35+/-17), 297 men, 206 women, recruited for a patent WPW syndrome. The location of AP was determined on a 12 lead ECG during atrial pacing at maximal preexcitation according to classical criteria. The location was confirmed at EPS. Eleven pts were excluded because the location remained not clearly defined. EPS was indicated for suspected or documented tachycardias (n=264), syncope (n=68) or was systematic in asymptomatic patients (n=171). RESULTS AS AP location was identified in 34 patients aged eight to 48 years (7%). Their mean age was younger than the age of remaining population (25+/-13 versus 36+/-17, p<0.001). According to the age, the prevalence of AS location was significantly higher in children and adolescents (14%) than after 40 years (3%) (p<0.01). There was no AS location among 108 patients aged more than 50 years. The maximal rate conducted over AP was lower in patients with AS location than in other locations either in control state (174+/-60 per minute versus 197+/-63 per minute) (p<0.01) or after isoproterenol (206+/-71 versus 248+/-69) (p<0.01). The number of induced reciprocating tachycardia (47% versus 57.5%), atrial fibrillation (15% versus 21%) and malign forms (12% versus 17%) did not differ significantly in patients with AS location and in other patients. Anterograde conduction disappeared spontaneously in three of six patients followed 8+/-1.5 years, and significantly increased in two other patients. CONCLUSIONS AS AP location in WPW syndrome was more frequent in children than in adults. The maximal rate conducted over the AP was lower than in other locations. The incidence decreased after 40 years. AS AP location was never noted after 50 years in our population. This disappearance with age should be taken into account for the indications of AS AP ablation.
Collapse
Affiliation(s)
- O Huttin
- Département de cardiologie et pathologies vasculaires, CHU Brabois, rue du Morvan, 54500 Vandoeuvre-lès-Nancy, France
| | | |
Collapse
|
21
|
Rostock T, Sydow K, Steven D, Lutomsky B, Servatius H, Drewitz I, Falke V, Müllerleile K, Ventura R, Meinertz T, Willems S. A new algorithm for concealed accessory pathway localization using T-wave-subtracted retrograde P-wave polarity during orthodromic atrioventricular reentrant tachycardia. J Interv Card Electrophysiol 2008; 22:55-63. [PMID: 18415672 DOI: 10.1007/s10840-008-9253-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2008] [Accepted: 03/04/2008] [Indexed: 11/21/2022]
Abstract
INTRODUCTION AP localization can be predicted by analyzing the polarity of the delta wave, QRS polarity, and R/S ratio in patients with Wolff-Parkinson-White syndrome. However, the estimation of AP location is limited in patients with concealed pathways during atrioventricular reentrant tachycardias (AVRT). Thus, we analyzed retrograde P-wave polarity during orthodromic AVRT and developed an algorithm to predict the localization of concealed accessory pathways (AP). METHODS AND RESULTS A total number of 131 patients with a single AP and inducible orthodromic AVRT were included. The initial 61 patients were analyzed retrospectively for algorithm development, whereas 70 patients were evaluated prospectively. The retrograde P-wave polarity was analyzed by subtracting the superimposing T-wave during orthodromic AVRT using custom-designed software. Four leads of the surface electrocardiogram (ECG) were identified to accurately distinguish AP locations assigned to four different regions around each AV annulus: I, aVR, aVL, and V(1). Lead V(1) was used to differentiate right (negative or isoelectric) from left (solely positive) APs. Retrograde P-wave in lead I was negative in left posterior APs exclusively and became more positive with an AP location shifting towards right anterior. P-wave polarity in lead aVR demonstrated a shift from a positive polarity from left APs to isoelectric in right APs. The opposite direction (shift from positive to isoelectric) was observed for lead aVL. The subsequently developed algorithm for concealed AP localization using these surface ECG leads demonstrated a high sensitivity, specificity, and positive predictive value particularly for common AP localizations (left posterior and inferior, and right septal) when applied in a prospective fashion. CONCLUSION Concealed AP localization can be accurately predicted by the analysis of retrograde P-wave polarity during orthodromic AVRT using the algorithm derived from the presented study.
Collapse
Affiliation(s)
- Thomas Rostock
- Department of Cardiology, University Hospital Eppendorf, Martinistr. 52, 20246 Hamburg, Germany.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
HAGHJOO MAJID, MAHMOODI EBRAHIM, FARJAM FAZELIFAR AMIR, ALIZADEH ABOLFATH, JAFAR HASHEMI MOHAMMAD, EMKANJOO ZAHRA, ALI SADR-AMELI MOHAMMAD. Electrocardiographic and Electrophysiologic Predictors of Successful Ablation Site in Patients with Manifest Posteroseptal Accessory Pathway. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2007; 31:103-11. [DOI: 10.1111/j.1540-8159.2007.00933.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
23
|
Santilli RA, Spadacini G, Moretti P, Perego M, Perini A, Crosara S, Tarducci A. Anatomic distribution and electrophysiologic properties of accessory atrioventricular pathways in dogs. J Am Vet Med Assoc 2007; 231:393-8. [PMID: 17669040 DOI: 10.2460/javma.231.3.393] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the anatomic distribution and electrophysiologic properties of accessory pathways (APs) in dogs. DESIGN Case series. ANIMALS 10 dogs with tachyarrhythmias associated with an AP. PROCEDURES Each dog underwent electrophysiologic testing to determine the inducibility of documented and undocumented arrhythmias and to identify location, conduction properties, and antegrade and retrograde effective refractory periods of the APs. Radiofrequency catheter ablation was then performed. RESULTS 15 APs were identified; 7 dogs each had a single AP, and 3 had multiple APs. Fourteen of the 15 APs were right-sided (6 right free wall, 4 posteroseptal, 3 midseptal, and 1 anteroseptal), and 1 was left-sided (left free wall). All APs conducted in an all-or-none fashion. Unidirectional retrograde conduction was observed in 11 APs, and bidirectional conduction was observed in 4. All documented tachyarrhythmias could be induced during electrophysiologic testing; atrial fibrillation was also inducible in 2 dogs. Mean +/- SD cycle duration of orthodromic atrioventricular reciprocating tachycardia was 215.80 +/- 44.87 milliseconds. Mean shortest R-R interval during atrial fibrillation was 247.33 +/- 83.17 milliseconds. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that in dogs, most APs are right-sided, had unidirectional retrograde conduction, and are associated with various arrhythmias, including orthodromic atrioventricular reciprocating tachycardia and atrial fibrillation without evidence of pre-excitation.
Collapse
Affiliation(s)
- Roberto A Santilli
- Clinica Veterinaria Malpensa, Via Marconi, 27, 21017 Samarate, Varese, Italy
| | | | | | | | | | | | | |
Collapse
|
24
|
Callans DJ, Jacobson JT. Nonpharmacologic Treatment of Tachyarrhythmias. Cardiovasc Ther 2007. [DOI: 10.1016/b978-1-4160-3358-5.50026-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
25
|
Gaita F, Montefusco A, Riccardi R, Scaglione M, Grossi S, Caponi D, Caruzzo E, Giustetto C, Bocchiardo M, Di Donna P. Acute and long-term outcome of transvenous cryothermal catheter ablation of supraventricular arrhythmias involving the perinodal region. J Cardiovasc Med (Hagerstown) 2006; 7:785-92. [PMID: 17060803 DOI: 10.2459/01.jcm.0000250865.25413.44] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Cryoenergy is a new valuable treatment option to perform ablation close to the atrioventricular (AV) node in the cure of supraventricular tachycardias because of its favourable properties, such as the possibility of creating reversible lesions. The aim of this study was to report our experience on the effectiveness and safety of catheter cryoablation performed in "critical areas" to treat a large cohort of patients with supraventricular arrhythmias. METHODS One hundred and thirty-one patients suffering from supraventricular tachycardias underwent catheter cryoablation using a 7F catheter. Eighty-seven patients presented with AV nodal re-entrant tachycardia (AVNRT), 39 had accessory pathways (APs) either manifest or concealed (15 midseptal, 24 parahissian), three had ectopic right atrial tachycardia (AT), and two patients had a permanent junctional reciprocating tachycardia (PJRT). When the optimal parameters were recorded, ice mapping at -30 degrees C was performed for 80 s to validate the ablation site. If the expected result occurred, cryoablation was carried out by lowering the temperature to -75 degrees C for 4 min. RESULTS In two patients cryoablation was not performed because of technical reasons. Cryoablation was acutely successful in 84 out of 85 patients with AVNRT, in 37 of 39 with APs and in all patients with AT and PJRT. No complications occurred in any patient. Transient AV conduction impairment occurred in seven patients with midseptal APs and in two patients with AVNRT. In particular, in these patients no late permanent AV block was observed at follow-up. At a mean follow-up of 27 +/- 12.9 months, clinical success rate was 87%. CONCLUSIONS Cryoablation is a safe and effective technique with a high success rate in the long term. It may be particularly useful when performing ablation close to the AV node or His bundle owing to the possibility of validating the ablation site with ice mapping, which creates only a reversible lesion, mainly in the midseptal APs.
Collapse
Affiliation(s)
- Fiorenzo Gaita
- Division of Cardiology, Cardinal Massaia Hospital, Asti, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Meiltz A, Weber R, Halimi F, Defaye P, Boveda S, Tavernier R, Kalusche D, Zimmermann M. Permanent form of junctional reciprocating tachycardia in adults: peculiar features and results of radiofrequency catheter ablation. ACTA ACUST UNITED AC 2006; 8:21-8. [PMID: 16627404 DOI: 10.1093/europace/euj007] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
AIM PJRT occurs predominantly in infants and children and is limited to small series in adults. The aim of this study was to describe the clinical presentation, electrophysiological characteristics, feasibility and safety of radiofrequency ablation, and the long-term prognosis in a large group of adult patients with the permanent form of junctional reciprocating tachycardia (PJRT). METHODS AND RESULTS Forty-nine adult patients (22 male and 27 female; mean age 43+/-16) with a diagnosis of PJRT confirmed at electrophysiological study were included. Eight patients (16%) presented with tachycardia-induced cardiomyopathy (TIC). Ventricular rate was 146+/-30 bpm. The arrhythmia was permanent or incessant in 23/49 cases (47%) and paroxysmal in 26/49 (53%). A significant correlation was found between symptom duration and tachycardia rate (r(2)=0.12, P=0.01). The accessory pathway (AP) was located in the right posteroseptal region in 37 cases (76%) and in atypical sites in 12 cases (24%). Patients with the incessant or permanent form of PJRT had longer duration of symptoms, more frequently TIC and a slower tachycardia rate. Radiofrequency catheter ablation was initially successful in 46 cases (94%) without any serious complication. Long-term success rate was 100% (49/49 patients) in the absence of any antiarrhythmic drug treatment (mean follow-up 49+/-38 months). Regression of TIC was observed in all cases (8/8). CONCLUSION PJRT in adults is often paroxysmal (53%), and the retrograde slowly conducting, decremental AP is not infrequently in a non-posteroseptal location. Radiofrequency catheter ablation is highly effective and should be considered as the treatment of first choice in adult patients with PJRT.
Collapse
Affiliation(s)
- Alexandre Meiltz
- Cardiovascular Department, Hôpital de La Tour 1 Avenue JD Maillard, CH-1217 Meyrin, Geneva, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Gaita F, Haissaguerre M, Giustetto C, Grossi S, Caruzzo E, Bianchi F, Richiardi E, Riccardi R, Hocini M, Jais P. Safety and efficacy of cryoablation of accessory pathways adjacent to the normal conduction system. J Cardiovasc Electrophysiol 2003; 14:825-9. [PMID: 12890043 DOI: 10.1046/j.1540-8167.2003.03076.x] [Citation(s) in RCA: 112] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
UNLABELLED Cryoablation of Septal Accessory Pathways. INTRODUCTION Catheter ablation has become a routine treatment for patients with Wolff-Parkinson-White syndrome because of its low risk and high efficacy; however, radiofrequency ablation in the septum close to the AV node or His bundle still carries a definite risk for AV block. Cryoenergy catheter ablation has recently become available. This technique has specific features, such as the ability to create reversible loss of function to predict the effects of ablation (ice mapping) and the adherence of the catheter tip to the endocardium with freezing, which avoids the risk for dislodgment. Both of these characteristics may minimize the risk of complications. The aim of this study was to analyze the effectiveness and safety of catheter cryoablation in 20 patients with para-Hisian or midseptal accessory pathways (AP). METHODS AND RESULTS Eleven patients with para-Hisian and 9 patients with midseptal AP underwent catheter cryoablation. Ice mapping at -30 degrees C was performed to ascertain the disappearance of AP conduction and the absence of impairment of AV nodal conduction. If the expected result was obtained, cryoablation was performed by lowering the temperature to -75 degrees C for 4 minutes in order to create a permanent lesion. Cryoablation was successful in all patients using a mean of 1.2 +/- 0.4 applications. Recurrences occurred in 4 patients (20%) who underwent a second successful cryoablation session. No complications were observed. CONCLUSION Cryoablation appears to be a safe and effective technique for ablation of APs close to the AV node or His bundle because of the ability to predict the acute effects of ablation with ice mapping before creation of an irreversible lesion.
Collapse
Affiliation(s)
- Fiorenzo Gaita
- Division of Cardiology, Ospedale Mauriziano di Torino, Torino, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Basso C, Corrado D, Rossi L, Thiene G. Ventricular preexcitation in children and young adults: atrial myocarditis as a possible trigger of sudden death. Circulation 2001; 103:269-75. [PMID: 11208688 DOI: 10.1161/01.cir.103.2.269] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Sudden death (SD) in ventricular preexcitation (VP) syndrome is believed to be the result of atrial fibrillation with rapid ventricular response over the accessory pathway. Previous reports are anecdotal and often lack autopsy validation. METHODS AND RESULTS Prevalence and clinicopathological features of VP were investigated in a series of 273 SDs in children and young adults (aged <or=35 years). Site of accessory atrioventricular (AV) connection was predicted by 12-lead ECG. Right and left AV ring together with the sinoatrial and AV septal junction were studied in serial histological sections. Ten patients (3.6%; male, mean age 24+/-7 years) had VP: 8 had Wolff-Parkinson-White (WPW) and 2 had Lown-Ganong-Levine (LGL) syndrome. Six patients had previous symptoms, and SD occurred at rest in all but 1. Pathological substrates of LGL consisted of AV-node hypoplasia and right-sided atrio-Hisian tract, respectively. In the 8 WPW patients, 10 total accessory AV pathways consisting of ordinary myocardium were found (7 left lateral, 2 right posterolateral, and 1 septal). These pathways were close to the endocardium (mean distance, 750+/-530 microm) and 310+/-190 microm thick. In 4 WPW patients (50%), isolated acute atrial myocarditis was found, which was polymorphous in 1 and lymphocytic in 3. CONCLUSIONS VP accounted for 3.6% of SD in young people and was not preceded by warning symptoms in 40%. A left accessory pathway was the most frequent substrate, and its subendocardial location supports the feasibility of catheter ablation. Isolated atrial myocarditis may act as a trigger of paroxysmal atrial fibrillation that leads to SD.
Collapse
Affiliation(s)
- C Basso
- Department of Pathology, University of Padua Medical School, Padua, Italy
| | | | | | | |
Collapse
|
29
|
Yamane T, Jaïs P, Shah DC, Hocini M, Peng JT, Deisenhofer I, Clémenty J, Haïssaguerre M. Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation. Circulation 2000; 102:2565-8. [PMID: 11085957 DOI: 10.1161/01.cir.102.21.2565] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Radiofrequency catheter ablation of accessory pathways (APs) is very effective in all but a minority of patients. We examined the usefulness and safety of irrigated-tip catheters in treating patients with APs resistant to conventional catheter ablation. METHODS AND RESULTS Among 314 APs in 301 consecutive patients, conventional ablation failed to eliminate AP conduction in 18 APs in 18 patients (5.7%), 6 of which were located in the left free wall, 5 in the middle/posterior-septal space, and 7 inside the coronary sinus (CS) or its tributaries. Irrigated-tip catheter ablation was subsequently performed with temperature control mode (target temperature, 50 degrees C), a moderate saline flow rate (17 mL/min), and a power limit of 50 W (outside CS) or 20 to 30 W (inside CS) at previously resistant sites. Seventeen of the 18 resistant APs (94%) were successfully ablated with a median of 3 applications using irrigated-tip catheters. A significant increase in power delivery was achieved (20.3+/-11.5 versus 36.5+/-8.2 W; P:<0.01) with irrigated-tip catheters, irrespective of the AP location, particularly inside the CS or its tributaries. No serious complications occurred. CONCLUSIONS Irrigated-tip catheter ablation is safe and effective in eliminating AP conduction resistant to conventional catheters, irrespective of the location.
Collapse
Affiliation(s)
- T Yamane
- Hôpital Cardiologique du Haut-Lévêque, Bordeaux-Pessac, France
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Shah DC, Takahashi A, Jaïs P, Hocini M, Peng JT, Clementy J, Haïssaguerre M. Tracking dynamic conduction recovery across the cavotricuspid isthmus. J Am Coll Cardiol 2000; 35:1478-84. [PMID: 10807450 DOI: 10.1016/s0735-1097(00)00600-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVES We sought to assess the dynamic temporal course of conduction recovery during and after radiofrequency (RF) catheter ablation of the cavotricuspid isthmus. BACKGROUND Although cavotricuspid isthmus block is accepted as the best end point of ablation for typical flutter, conduction recovery is thought to underlie many eventual recurrences. Its time course and frequency have not been determined. METHODS In a prospective group of 30 patients (26 men and 4 women, age 64 +/- 12 years) undergoing ablation of typical flutter in the cavotricuspid isthmus, the morphology of the P wave during pacing from the low lateral right atrium after achievement of complete isthmus block was identified as a reference. Regression of this morphologic P wave change was confirmed to be associated with intracardiac evidence of the recovery of cavotricuspid isthmus conduction and was observed throughout the procedure both during ablation in sinus rhythm (n = 15, group B) and just after flutter termination (n = 15, group A). RESULTS Stable complete isthmus block was achieved in all patients; 29 had a terminal positivity of the paced P wave. Flutter termination resulted in stable block and terminal P wave positivity in three patients, transient terminal P wave positivity and transient block despite continuing RF at the same site in five patients and no block in the remaining seven patients. Conduction recovery identified by recovery of P wave changes was nearly as common (48%) during ablation in sinus rhythm. Multiple recoveries were noted in some patients, and 72% of all recoveries occurred within 1 min. Conduction recovery was only rarely associated with coagulum, impedance elevation or pops. CONCLUSIONS Conduction recovery in the cavotricuspid isthmus is common during and after ablation and can be accurately, dynamically and continuously observed by monitoring the recovery of the low lateral right atrial paced P wave change.
Collapse
Affiliation(s)
- D C Shah
- CHU de Bordeaux, Hôpital Cardiologique du Haut-Lévêque, Bordeaux-Pessac, France
| | | | | | | | | | | | | |
Collapse
|
31
|
Basiouny T, de Chillou C, Fareh S, Kirkorian G, Messier M, Sadoul N, Chevalier P, Magnin-Poull I, Blankoff I, Chen J, Touboul P, Aliot E. Accuracy and limitations of published algorithms using the twelve-lead electrocardiogram to localize overt atrioventricular accessory pathways. J Cardiovasc Electrophysiol 1999; 10:1340-9. [PMID: 10515558 DOI: 10.1111/j.1540-8167.1999.tb00189.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
INTRODUCTION The purpose of this study was to evaluate the accuracy and limitations of published algorithms using the 12-lead ECG to localize AV accessory pathways (APs). METHODS AND RESULTS The 11 relevant algorithms found in the literature (MEDLINE database and major scientific sessions) were tested on a series of 266 consecutive patients who successfully underwent radiofrequency catheter ablation of a single overt AV AP. The positive predictive values (PPV) of the algorithms in applicable patients were significantly lower for algorithms with > 6 accessory location sites (40.6% +/- 10.9% vs 61.2% +/- 8.0%; P < 0.03) and show a tendency for algorithms not relying on delta wave polarity but on QRS polarity only (36.6% +/- 11.2% vs 52.3% +/- 13.1%; P = 0.09). The PPV in applicable patients is related to the AP location (P < 0.001) and ranked from the highest to the lowest as follows: left lateral (mean PPV = 86.3%), posteroseptal (mean PPV = 65.2%), right anteroseptal (mean PPV = 45.2%), and right posterolateral (mean PPV = 23.4%). CONCLUSION Our study suggests that the accuracy of algorithms relying on the 12-lead ECG depends on AP locations as defined in the algorithms and on the number of AP sites. The accuracy tends to be lower when delta wave polarity is not included in the algorithm's architecture. This should be considered when using these algorithms or when building new ones.
Collapse
Affiliation(s)
- T Basiouny
- Service de Cardiologie, Hôpital Central, Nancy, France
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Mont L, Valentino M, Vacca M, Aguinaga L, Matas M, Herreros B, Brugada J. [Analysis of local electrograms and characteristics of the ablation procedure in left-sided accessory pathways that required five or more pulses of radiofrequency]. Rev Esp Cardiol 1999; 52:570-6. [PMID: 10439657 DOI: 10.1016/s0300-8932(99)74973-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
INTRODUCTION AND OBJECTIVES Radiofrequency ablation of left sided accessory pathways requires multiple pulses in some patients due to different factors such as inadequate mapping, inappropriate tissue electrode contact and particular anatomic factors. However these characteristics have not been specifically analyzed. METHODS We have studied a prospective ablative series of 65 consecutive patients with left-sided pathways submitted to radiofrequency ablation by a simplified technique. In every application point, we analyzed the electrogram features, application point, impedance, potency and temperature. RESULTS 52 patients (80%) required less than 5 radiofrequency pulses (group A) and 13 (20%) required > or = than 5 pulses (group B). The presence of a suggestive potential accessory pathway in local electrogram was similar in both groups and there were no differences in the local A-V or V-A intervals. However, in patients with pre-excitation the Delta-V interval was shorter in group A than in group B (8 ms vs 15 ms; p < 0.001). Furthermore, the impedance observed from the ablation point in group A was lower (108 +/- 12 vs 121 +/- 22 ohms; p < 0.001), and the maximum watts required to reach the predetermined temperature was higher in group A (42 +/- 16 vs 31 +/- 18 watts; p < 0.001). Final success of the procedure was 100%. CONCLUSIONS Patients requiring more than 5 radiofrequency pulses had electrograms and tissue contact equal or better than those requiring less than 5 pulses. This suggests that difficulties encountered in some procedures can be due to anatomical factors rather than inaccurate mapping or insufficient tissue contact.
Collapse
Affiliation(s)
- L Mont
- Unidad de Arritmias, Hospital Clínic, Universidad de Barcelona.
| | | | | | | | | | | | | |
Collapse
|
33
|
Tai CT, Chen SA, Chiang CE, Chang MS. Characteristics and radiofrequency catheter ablation of septal accessory atrioventricular pathways. Pacing Clin Electrophysiol 1999; 22:500-11. [PMID: 10192859 DOI: 10.1111/j.1540-8159.1999.tb00478.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Septal accessory AV pathways are located in the complex AV septal space that also contains the specialized conduction system. They have unique electrocardiographical and electrophysiological characteristics to be differentiated from free-wall accessory pathways. Some of the septal pathways have AV nodelike conduction properties and produce a similar activation sequence in the retrograde conduction. Several methods have been developed to distinguish them from AV nodal pathways. Radiofrequency catheter ablation using the titration method and endocardial approach without entrance into the coronary sinus is effective in eliminating most of the septal accessory pathways without impairment of AV conduction. However, some posteroseptal accessory pathways may require energy application inside the coronary sinus, thus information of the coronary sinus anatomy is important for preventing complication.
Collapse
Affiliation(s)
- C T Tai
- Department of Medicine, National Yang-Ming University, School of Medicine, Taiwan, R.O.C
| | | | | | | |
Collapse
|
34
|
Belhassen B, Viskin S, Fish R, Glick A, Glikson M, Eldar M. Catheter-induced mechanical trauma to accessory pathways during radiofrequency ablation: incidence, predictors and clinical implications. J Am Coll Cardiol 1999; 33:767-74. [PMID: 10080479 DOI: 10.1016/s0735-1097(98)00643-3] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVES To evaluate the incidence, predictors and clinical implications of nonintentionally catheter-induced mechanical trauma to accessory pathways during radiofrequency ablation procedures. BACKGROUND Data on the incidence and significance of catheter-induced trauma to accessory pathways are scarce. METHODS Consecutive patients (n = 381) undergoing radiofrequency ablation of accessory pathways at two different institutions were closely monitored for appearance of mechanical block of accessory pathways during catheter manipulation. RESULTS Mechanical trauma to accessory pathways was observed in 37 (9.7%) patients. According to a multivariate analysis, the only independent variable associated with this phenomenon was the anatomical pathway location (p = 0.0001). The incidence of trauma of either right anteroseptal (38.5%) or right atriofascicular pathways (33.3%) was significantly greater than that of pathways (< or =10%) at all remaining locations (p < 0.0001). The duration of conduction block observed ranged from < or =1 min to >30 min in 19% and 35% of patients, respectively. "Immediate" application of radiofrequency pulses at sites of mechanical block (<1 min after occurrence) was associated with a 78% long-term success rate at follow-up. This contrasted with a 25% long-term success rate in patients in whom pulses were delivered 30 min after occurrence of block ("delayed pulses"). Finally, in 24% of patients persistent trauma-induced conduction block led to discontinuation of the ablation procedure. CONCLUSIONS Trauma to accessory pathways is more common than previously recognized and frequently results in prolongation or discontinuation of the ablation procedure and in lower success rates. The only independent predictor of catheter-trauma to accessory pathways is the pathway location.
Collapse
Affiliation(s)
- B Belhassen
- Department of Cardiology, Tel-Aviv Sourasky Medical Center, Tel-Aviv University, Sackler School of Medicine, Israel.
| | | | | | | | | | | |
Collapse
|
35
|
Gaita F, Haissaguerre M, Scaglione M, Jais P, Riccardi R, Lamberti F, Calò L. Catheter ablation in a patient with a congenital giant right atrial diverticulum presented as Wolff-Parkinson-White syndrome. Pacing Clin Electrophysiol 1999; 22:382-5. [PMID: 10087558 DOI: 10.1111/j.1540-8159.1999.tb00457.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A young woman symptomatic for tachycardia showed right ventricular preexcitation on the surface ECG with a pattern during induced atrial fibrillation suggestive of multiple APs. Noninvasive imaging techniques performed prior to catheter ablation demonstrated the presence of a giant right atrial diverticulum confirmed by hemodynamic procedure. This structure functioned as an enormous accessory AP. We performed catheter ablation of this pathway using a special 4-mm multipolar catheter inside the diverticulum. This is the first case of such as anomaly being successfully treated with catheter ablation.
Collapse
Affiliation(s)
- F Gaita
- Division of Cardiology, Hospital of Asti, Italy
| | | | | | | | | | | | | |
Collapse
|
36
|
Calkins H, Yong P, Miller JM, Olshansky B, Carlson M, Saul JP, Huang SK, Liem LB, Klein LS, Moser SA, Bloch DA, Gillette P, Prystowsky E. Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: final results of a prospective, multicenter clinical trial. The Atakr Multicenter Investigators Group. Circulation 1999; 99:262-70. [PMID: 9892593 DOI: 10.1161/01.cir.99.2.262] [Citation(s) in RCA: 363] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The purpose of this study was to evaluate the safety and efficacy of a temperature-controlled radiofrequency catheter ablation system. METHODS AND RESULTS The patient population included 1050 patients who had undergone ablation of atrioventricular nodal reentrant tachycardia (AVNRT), an accessory pathway (AP), or the atrioventricular junction (AVJ). Ablation was successful in 996 patients. The probability of success was highest among patients who had undergone ablation of the AVJ, lowest in patients who had undergone ablation of an AP, and in between for patients who had undergone ablation of AVNRT. A major complication occurred in 32 patients. Four variables predicted ablation success (AVJ, AVNRT, or left free wall AP ablation and an experienced center). Four factors predicted arrhythmia recurrence (right free wall, posteroseptal, septal, and multiple APs). Two variables predicted development of a complication (structural heart disease and the presence of multiple targets), and 3 variables predicted an increased risk of death (heart disease, lower ejection fraction, and AVJ ablation). CONCLUSIONS These findings may serve as a guide to clinicians considering therapeutic options in patients who are candidates for ablation.
Collapse
Affiliation(s)
- H Calkins
- Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Weismüller P, Trappe HJ. [Cardiology update. I: Electrophysiology]. MEDIZINISCHE KLINIK (MUNICH, GERMANY : 1983) 1999; 94:15-28. [PMID: 10081286 DOI: 10.1007/bf03044691] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- P Weismüller
- Medizinische Klinik II (Schwerpunkte Kardiologie und Angiologie), Universitätsklinik Marienhospital, Ruhr-Universität Bochum.
| | | |
Collapse
|
38
|
Abstract
This review summarizes the results of placebo-controlled trials of propafenone, a class IC antiarrhythmic drug, in patients with supraventricular tachycardia, atrial fibrillation (AF), and atrial flutter. Success rates for cardioversion from AF or flutter to sinus rhythm of 9-93% have been obtained with intravenous propafenone. The duration of arrhythmia is an important factor in the degree of success. The use of a single oral dose has also been reported to be effective in a number of studies. Several placebo-controlled studies have confirmed the effectiveness of propafenone in the long-term suppression of both suproventricular tachycardia and AF and flutter. These reported trials have shown consistent benefit with propafenone compared with placebo in preventing arrhythmia recurrence. The adverse side effect profile for propafenone has also been reviewed with particular reference to the potential for proarrhythmia. The rate of side effects is dose-dependent and tends to be higher in patients with underlying structural heart disease. Overall propafenone has been shown to be an effective antiarrhythmic drug with an acceptable side effect profile for the acute and long-term treatment of supraventricular arrhythmias.
Collapse
Affiliation(s)
- A P Rae
- Glasgow Royal Infirmary, Scotland, United Kingdom
| |
Collapse
|
39
|
Takahashi A, Shah DC, Jaïs P, Hocini M, Clementy J, Haïssaguerre M. Specific electrocardiographic features of manifest coronary vein posteroseptal accessory pathways. J Cardiovasc Electrophysiol 1998; 9:1015-25. [PMID: 9817553 DOI: 10.1111/j.1540-8167.1998.tb00879.x] [Citation(s) in RCA: 49] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Some posteroseptal accessory pathways (APs) can be successfully ablated by radiofrequency current only from inside the coronary sinus (CS) or its branches, because of an absolute or relatively epicardial location. The aim of this study was to identify ECG features of manifest posteroseptal APs requiring ablation in the CS or the middle cardiac veins (MCVs). METHODS AND RESULTS One hundred seventeen consecutive patients with manifest posteroseptal APs successfully ablated: (1) > or = 1 cm deep inside the MCV (group MCV: n = 13); (2) inside the CS, including the area adjacent to the MCV ostium (group CS: n = 10); (3) at the right (group R: n = 60); or (4) the left posteroseptal endocardial region (group L: n = 34) were included. We reviewed delta wave polarity (initial 40 msec) and QRS morphology during sinus rhythm and atrial pacing as well as electrogram characteristics in these patients. The local target site electrogram in groups MCV and CS was characterized by a longer atrial to ventricular electrogram interval, suggesting a longer course of the pathway and more frequent recording of a presumptive AP potential compared to the group ablated at the right or left endocardium. The most sensitive ECG feature for group CS or group MCV was a negative delta wave in lead II in sinus rhythm (87%), but specificity (79%) and positive predictive value (50%) were relatively low. A steep positive delta wave in aVR during maximal preexcitation possessed the highest specificity and positive predictive value (98% and 88%, sensitivity 61%) which increased to 99% and 91%, respectively, when combined with a deep S wave in V6 (R wave < or = S wave). CONCLUSION These data suggest that posteroseptal APs ablated inside the coronary venous system have highly specific features, including the combination of a steep positive delta wave in lead aVR and a deep S wave in lead V6 (R wave < or = S wave) during maximal preexcitation. The highest sensitivity is provided by a negative delta wave in lead II. These findings may be helpful for anticipating and planning an epicardial ablation strategy.
Collapse
Affiliation(s)
- A Takahashi
- Service d'Electrophysiologie Cardiaque, Hopital Cardiologique du Haut-Lévêque, Bordeaux-Pessac, France
| | | | | | | | | | | |
Collapse
|
40
|
Abstract
Cardiac dysfunction is not limited to the elderly. In fact, the forms of tachycardia discussed in this article usually begin before age 40. The authors summarize the mechanisms involved and the findings on electrocardiography that help identify the type of dysrhythmia in patients presenting with palpitations and other signs of possible cardiac disease. In addition, they describe the procedure that has revolutionized treatment for reentrant tachycardia: closed-chest radiofrequency catheter ablation.
Collapse
Affiliation(s)
- B J Karas
- Department of Medicine, Medical College of Ohio, Toledo 43699-0008, USA
| | | |
Collapse
|
41
|
Shpun S, Gepstein L, Hayam G, Ben-Haim SA. Guidance of radiofrequency endocardial ablation with real-time three-dimensional magnetic navigation system. Circulation 1997; 96:2016-21. [PMID: 9323094 DOI: 10.1161/01.cir.96.6.2016] [Citation(s) in RCA: 105] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Ablation therapy for certain arrhythmias requires the formation of complex lesions based on electrical and anatomic mapping. We tested the accuracy and reproducibility of a nonfluoroscopic mapping and navigation (NFM) system to guide delivery of radiofrequency (RF) energy in the right atrium (RA) of swine. METHODS AND RESULTS The NFM system uses an ultralow magnetic field to measure the real-time three-dimensional (3D) location of the tip of the locatable catheter. While in stable contact with the endocardium, between 30 and 40 consecutive tip locations were sampled and used for the 3D reconstruction of the RA geometry. The location of the catheter tip was presented in real time, superimposed over the RA geometry. We selected a point on the 3D reconstruction and delivered RF energy to that site via the tip of the locatable catheter. The catheter was then completely withdrawn and renavigated twice to the same point, at which RF energy was delivered again. At autopsy, the distance between the centers of the three ablation points (mean+/-SEM) was 2.3+/-0.5 mm (n=27). Similarly, we used the NFM system to guide the generation of linear lesions. The measured length of the linear lesions on the NFM 3D view was close to the actual lesion length measured at autopsy (correlation coefficient, .96; P=.002; n=6). Furthermore, the location, shape, and continuity of the linear lesions corresponded to the autopsy findings. CONCLUSIONS We conclude that the NFM system can guide the application of RF energy without the use of fluoroscopy in a highly accurate and reproducible manner.
Collapse
Affiliation(s)
- S Shpun
- Cardiovascular System Laboratory, The Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel
| | | | | | | |
Collapse
|
42
|
Molin F, Savard P, Dubuc M, Kus T, Tremblay G, Nadeau R. Spatial resolution and role of pacemapping during ablation of accessory pathways. Pacing Clin Electrophysiol 1997; 20:683-94. [PMID: 9080495 DOI: 10.1111/j.1540-8159.1997.tb03887.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The objectives of this study were: (1) to evaluate quantitatively the spatial resolution of pacemapping; and (2) to assess the predictive value and role of pacemapping for the catheter ablation of overt APs. Sixty-three unipolar leads were used instead of the standard 12-lead ECG to acquire more information and assess the intrinsic accuracy of pacemapping. Spatial resolution was evaluated in 19 patients for whom data were recorded during bipolar ventricular pacing near the AV ring using the three electrode pairs of a quadripolar ablation catheter with a 5-mm interelectrode spacing. The predictive value was assessed in 27 patients with overt APs who underwent RF ablation; their data were recorded during pacing at the site of successful ablation and at one or two sites where RF energy delivery was ineffective. Data from different beats were compared visually by using body surface potential maps and quantitatively by computing average correlation coefficients (r). Reproducibility was high for paced beats (r = 0.98 +/- 0.02). Displacements of 5 mm of the pacing site could be detected with a sensitivity of 90% and a specificity of 87%. Correlation between pacing at successful ablation sites and preexcited sinus rhythm was low (r = 0.79 +/- 0.11) and the ablation outcome could be predicted with a negative prediction accuracy of 87% and a positive prediction accuracy of 49%. Despite an excellent spatial resolution, pacemapping is of limited value for the identification of successful AP ablation sites, probably because APs can be interrupted at some distance from their ventricular insertion point.
Collapse
Affiliation(s)
- F Molin
- Research Center, Hôpital du Sacré-Coeur de Montréal, Québec, Canada.
| | | | | | | | | | | |
Collapse
|
43
|
Berger RD, Nsah E, Calkins H. Signal-averaged intracardiac electrograms: a new method to detect kent potentials. J Cardiovasc Electrophysiol 1997; 8:155-60. [PMID: 9048246 DOI: 10.1111/j.1540-8167.1997.tb00777.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
INTRODUCTION In patients with manifest accessory pathways, Kent potentials are often difficult to identify even at sites of successful catheter ablation, due largely to signal noise and catheter instability. We hypothesized that signal averaging the intracardiac electrogram recorded from the ablation catheter over a number of beats would improve the signal-to-noise ratio of the electrogram and aid in the detection of Kent potentials at accessory pathway locations. METHODS AND RESULTS We retrospectively analyzed distal-pair electrograms recorded from 9 successful, 6 transiently successful, and 10 failed ablation sites in 10 patients with manifest accessory pathways who underwent catheter ablation. We developed custom software to finely align 20 to 30 consecutive sinus beats and compute the signal average of the electrogram (SAE) for each site. Kent potentials were classified as probable, possible, or absent in the raw ablation site electrogram and the SAE base on morphologic criteria. A measure of beat-to-beat signal instability, the variability quotient (VQ), was also computed for each site. Probable Kent potentials were found in the raw ablation site electrogram at only 2 of the 15 successful and transiently successful sites, but were found in the SAE at 10 of these sites (P = 0.008). Eight of the 9 successful sites had VQ < 0.2, suggesting stable catheter-tissue contact, while 3 of the 6 transiently successful sites had VQ > 0.2, indicating unstable contact. CONCLUSIONS Signal averaging the intracardiac ablation site electrogram enhances detection of Kent potentials at accessory pathway locations. Catheter instability can be quantified by signal variability analysis and, when high, may predict lack of successful ablation even at sites where Kent potentials are present.
Collapse
Affiliation(s)
- R D Berger
- Johns Hopkins School of Medicine, Baltimore, Maryland 21287, USA
| | | | | |
Collapse
|
44
|
Affiliation(s)
- J J Gallagher
- Sanger Clinic, Carolinas Heart Institute, Charlotte, North Carolina 28203, USA
| |
Collapse
|
45
|
Hluchy J, Wieczorek M, Tekiyeh M, Jurkovicova O, Sabin GV. Radiofrequency catheter ablation of a right atriofascicular (Mahaim) and two atrioventricular (Kent) accessory pathways in a single session. Clin Cardiol 1996; 19:751-4. [PMID: 8874997 DOI: 10.1002/clc.4960190915] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
This report describes the case of a 19-year-old patient with Ebstein's anomaly, who had an unusual combination of a right atriofascicular (Mahaim) and two ipsilateral right atrioventricular (Kent) accessory pathways participating in three types of antidromic and orthodromic reciprocating tachycardias in the absence of retrograde conduction over the bundle of His-atrioventricular node axis. All three pathways were ablated in a single session using temperature-guided radiofrequency current.
Collapse
Affiliation(s)
- J Hluchy
- Department of Cardiology and Angiology, Elisabeth Hospital, Essen, Germany
| | | | | | | | | |
Collapse
|
46
|
Callans DJ, Schwartzman D, Gottlieb CD, Marchlinski FE. Insights into the electrophysiology of accessory pathway-mediated arrhythmias provided by the catheter ablation experience: "learning while burning, part III". J Cardiovasc Electrophysiol 1996; 7:877-904. [PMID: 8884516 DOI: 10.1111/j.1540-8167.1996.tb00600.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The success of catheter ablation has greatly improved the care of patients with paroxysmal tachycardias and has caused a revolution in the practice of electrophysiology. Some investigators have expressed that concern over procedural success in an increasingly interventional specialty threatens to eclipse attempts to understand the physiology of arrhythmia syndromes. Alternatively, due to the precise and directed nature of the lesions created with radiofrequency energy, catheter ablation procedures have allowed investigation to continue at a more focused level. In this article, the insights provided by the catheter ablation experience into the physiology of arrhythmias mediated by accessory AV pathways will be reviewed. Although the learning process was sometimes delayed by the nearly immediate success of radiofrequency catheter ablation, difficult situations have continued to renew efforts for understanding at a deeper level. Conscious attempts at "learning while burning" will provide the opportunity to investigate aspects of bypass tract physiology that remain incompletely characterized, such as partial response to therapy and late recurrence.
Collapse
Affiliation(s)
- D J Callans
- Clinical Electrophysiology Laboratory, Philadelphia Heart Institute, Presbyterian Medical Center, Pennsylvania, USA
| | | | | | | |
Collapse
|
47
|
Widman LE, Tong DA. An algorithm for complete enumeration of the mechanisms of supraventricular tachycardias that use multiple atrioventricular, AV nodal, and/or Mahaim pathways. Artif Intell Med 1995; 7:361-86. [PMID: 7581629 DOI: 10.1016/0933-3657(95)00010-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The EINTHOVEN system is a model-based expert system that interprets the cardiac rhythm from the electrocardiogram. It simulates the expected behavior of realistic semi-quantitative cardiac models constructed by heuristic rules to generate interpretations that include both text descriptions and event-by-event causal explanations in the form of ladder diagrams. The simulation has been limited by an inability to predict all possible behaviors of hearts with more than one reentrant circuit. We now describe an algorithm that overcomes this limitation. Its output has been validated by an independent possibility-tree analysis. Timing and storage measurements are presented for models with up to three slow atrioventricular nodal pathways, four atrioventricular pathways, and a single atriofascicular (Mahaim) pathway. This is the first report in the literature of an algorithm that enumerates all possible mechanisms for reentrant supraventricular tachycardias that use atrioventricular, atrioventricular nodal, and/or atriofascicular pathways in humans.
Collapse
Affiliation(s)
- L E Widman
- University of Oklahoma Health Sciences Center, Oklahoma City 73104, USA
| | | |
Collapse
|
48
|
McMurray J, Rankin A. Cardiology--II: Treatment of heart failure and atrial fibrillation and arrhythmias. BMJ (CLINICAL RESEARCH ED.) 1994; 309:1631-5. [PMID: 7819948 PMCID: PMC2542004 DOI: 10.1136/bmj.309.6969.1631] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- J McMurray
- Department of Cardiology, Western General Hospital, Edinburgh
| | | |
Collapse
|