1
|
Tremblay C, Ruel J, Bourget JM, Laterreur V, Vallières K, Tondreau MY, Lacroix D, Germain L, Auger FA. A new construction technique for tissue-engineered heart valves using the self-assembly method. Tissue Eng Part C Methods 2014; 20:905-15. [PMID: 24576074 DOI: 10.1089/ten.tec.2013.0698] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Tissue engineering appears as a promising option to create new heart valve substitutes able to overcome the serious drawbacks encountered with mechanical substitutes or tissue valves. The objective of this article is to present the construction method of a new entirely biological stentless aortic valve using the self-assembly method and also a first assessment of its behavior in a bioreactor when exposed to a pulsatile flow. A thick tissue was created by stacking several fibroblast sheets produced with the self-assembly technique. Different sets of custom-made templates were designed to confer to the thick tissue a three-dimensional (3D) shape similar to that of a native aortic valve. The construction of the valve was divided in two sequential steps. The first step was the installation of the thick tissue in a flat preshaping template followed by a 4-week maturation period. The second step was the actual cylindrical 3D forming of the valve. The microscopic tissue structure was assessed using histological cross sections stained with Masson's Trichrome and Picrosirius Red. The thick tissue remained uniformly populated with cells throughout the construction steps and the dense extracellular matrix presented corrugated fibers of collagen. This first prototype of tissue-engineered heart valve was installed in a bioreactor to assess its capacity to sustain a light pulsatile flow at a frequency of 0.5 Hz. Under the light pulsed flow, it was observed that the leaflets opened and closed according to the flow variations. This study demonstrates that the self-assembly method is a viable option for the construction of complex 3D shapes, such as heart valves, with an entirely biological material.
Collapse
Affiliation(s)
- Catherine Tremblay
- 1 Département de génie mécanique, Faculté des sciences et de génie, Université Laval , Québec, Canada
| | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Kim H, Bergman R, Matyal R, Khabbaz KR, Mahmood F. Three-dimensional echocardiography and en face views of the aortic valve: technical communication. J Cardiothorac Vasc Anesth 2013; 27:376-80. [PMID: 23507016 DOI: 10.1053/j.jvca.2012.12.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2012] [Indexed: 01/30/2023]
Abstract
With the resurgence in popularity of aortic valve (AV) repair, detailed anatomical information of the AV has become invaluable for surgical decision making as well as for evaluation of success postrepair. Perioperative 3-dimensional echocardiography is optimally suited to assist in repair planning. The volumetric nature of the 3-dimensional data allows accurate derivation of qualitative and quantitative measurements. A uniform approach to imaging and description of echocardiographic AV anatomy is essential to facilitate communication across specialties.
Collapse
Affiliation(s)
- Han Kim
- Department of Anesthesia & Critical Care, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | | | | | | |
Collapse
|
3
|
|
4
|
Lang RM, Tsang W, Weinert L, Mor-Avi V, Chandra S. Valvular Heart Disease. J Am Coll Cardiol 2011; 58:1933-44. [DOI: 10.1016/j.jacc.2011.07.035] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Revised: 07/14/2011] [Accepted: 07/18/2011] [Indexed: 10/16/2022]
|
5
|
|
6
|
Three-Dimensional Echocardiography. Echocardiography 2009. [DOI: 10.1007/978-1-84882-293-1_31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
7
|
Kleijn SA, Kamp O. Clinical application of three-dimensional echocardiography: past, present and future. Neth Heart J 2009; 17:18-24. [PMID: 19148334 PMCID: PMC2626655 DOI: 10.1007/bf03086210] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Significant advances in three-dimensional echocardiography have made this modality a powerful diagnostic tool in the cardiology clinic. It can provide accurate and reliable measurements of chamber size and function, including the quantification of left ventricular mechanical dyssynchrony to guide patient selection for cardiac resynchron-isation therapy. Furthermore, three-dimensional echocardiography offers novel views and comprehensive anatomic definition of valvular and congenital abnormalities, improving diagnosis and preoperative planning. In addition, it is extremely useful in monitoring the effectiveness of surgical or percutaneous transcatheter interventions. As its efficacy for more and more clinical applications is demonstrated, it is clear that three-dimensional echocardiography has become part of the routine clinical diagnostic armamentarium. In this article, we describe the development of three-dimensional echocardiography over the last decades, review the scientific evidence for its current clinical use and discuss potential future applications. (Neth Heart J 2009;17:18-24.).
Collapse
Affiliation(s)
- S A Kleijn
- Department of Cardiology 4D 194, VU University Medical Center, Amsterdam, and Interuniversity Cardiology Institute of the Netherlands (ICIN), Utrecht, the Netherlands
| | | |
Collapse
|
8
|
Abstract
The introduction of three-dimensional (3D) imaging and its evolution from slow and labor-intense off-line reconstruction to real-time volumetric imaging is one of the most significant developments in ultrasound imaging of the heart of the past decade. This imaging modality currently provides valuable clinical information that empowers echocardiography with new levels of confidence in diagnosing heart disease. One major advantage of seeing the additional dimension is the improvement in the accuracy of the evaluation of cardiac chamber volumes by eliminating geometric modeling and the errors caused by foreshortened views. Another benefit of 3D imaging is the realistic views of cardiac valves capable of demonstrating numerous pathologies in a unique, noninvasive manner. This article reviews the major technological developments in 3D echocardiography and some of the recent literature that has provided the scientific basis for its clinical use.
Collapse
|
9
|
Correale M, Ieva R, Di Biase M. Real-time three-dimensional echocardiography: an update. Eur J Intern Med 2008; 19:241-8. [PMID: 18471671 DOI: 10.1016/j.ejim.2007.06.034] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2007] [Revised: 06/26/2007] [Accepted: 06/28/2007] [Indexed: 11/30/2022]
Abstract
Real-time three-dimensional echocardiography (RT3DE) is the only on-line 3D method based on real-time volumetric scanning, as compared with other 3D imaging techniques such as computed tomography and magnetic resonance imaging, which are based on post-acquisition reconstruction and not on volumetric scanning. In recent years, several studies have revealed possible advantages of 3DE in daily clinical practice. The aim of this manuscript is to give a brief review of the development of the clinical applications of RT3DE.
Collapse
Affiliation(s)
- Michele Correale
- Department of Cardiology, Ospedali Riuniti OO.RR, viale L Pinto, 1. 71100 Foggia, Italy.
| | | | | |
Collapse
|
10
|
Blot-Souletie N, Hébrard A, Acar P, Carrié D, Puel J. Comparison of Accuracy of Aortic Valve Area Assessment in Aortic Stenosis by Real Time Three-Dimensional Echocardiography in Biplane Mode versus Two-Dimensional Transthoracic and Transesophageal Echocardiography. Echocardiography 2007; 24:1065-72. [DOI: 10.1111/j.1540-8175.2007.00526.x] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
11
|
Badano LP, Dall'Armellina E, Monaghan MJ, Pepi M, Baldassi M, Cinello M, Fioretti PM. Real-time three-dimensional echocardiography: technological gadget or clinical tool? J Cardiovasc Med (Hagerstown) 2007; 8:144-62. [PMID: 17312431 DOI: 10.2459/jcm.0b013e3280116b50] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The complex anatomy of cardiac structures requires three-dimensional spatial orientation of images for a better understanding of structure and function, thereby improving image interpretation. Real-time three-dimensional echocardiography is a recently developed technique based on the design of an ultrasound transducer with a matrix array that rapidly acquires image data in a pyramidal volume. The simultaneous display of multiple tomographic images allows three-dimensional perspective and the anatomically correct examination of any structure within the volumetric image. As a consequence, it is less operator-dependent and hence more reproducible. Dedicated software systems and technologies are based on high-performance computers designed for graphic handling of three-dimensional images by providing possibilities beyond those obtainable with echocardiography. This methodology allows simultaneous display of multiple superimposed planes in an interactive manner as well as a quantitative assessment of cardiac volumes and ventricular mass in a three-dimensional format without a pre-established assumption of cardiac chamber geometry. In addition, myocardial contraction and/or perfusion abnormalities are clearly identified. Finally, real-time three-dimensional colour Doppler flow mapping enables complete visualisation of the regurgitant jet and new ways of assessing regurgitant lesion severity. Thus, this technique expands the abilities of non-invasive cardiology and may open new doors for the evaluation of cardiac diseases. In this article, current and future clinical applications of real-time three-dimensional echocardiography are reviewed.
Collapse
Affiliation(s)
- Luigi P Badano
- Department of Cardiopulmonary Sciences, University Hospital of Udine, Udine, Italy.
| | | | | | | | | | | | | |
Collapse
|
12
|
Vengala S, Nanda NC, Dod HS, Singh V, Agrawal G, Sinha A, Khanna D, Upendram SK, Chockalingam A, McGiffin DC, Kirklin JK, Pacifico AD. Usefulness of Live Three‐Dimensional Transthoracic Echocardiography in Aortic Valve Stenosis Evaluation. ACTA ACUST UNITED AC 2007; 13:279-84. [PMID: 15365294 DOI: 10.1111/j.1076-7460.2004.02710.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Aortic valve stenosis (AS) severity can be estimated by various modalities. Due to some of the limitations of the currently available methods, the usefulness of live three-dimensional transthoracic echocardiography (3D TTE) in the assessment of AS was explored. Live 3D TTE was able to visualize the aortic valve orifice in all 11 patients studied. Live 3D TTE correctly estimated the severity of AS in all 10 patients in whom AS severity could be evaluated at surgery. These included eight patients with severe AS and two with moderate AS. Two of these 10 patients with AS had associated hypertrophic cardiomyopathy and underwent myectomy at the time of aortic valve replacement. Aortic valve orifice area measurements by live 3D TTE correlated well with intraoperative three-dimensional transesophageal echocardiographic reconstruction measurements (r=0.85) but not as well with two-dimensional transesophageal echocardiography measurements (r=0.64). Live 3D TTE measurements of the aortic valve orifice area also did not correlate well with two-dimensional transthoracic echocardiography measurements (r=0.46) but the number of patients studied with two-dimensional transthoracic echocardiography was smaller (only seven) and four of these did not undergo two-dimensional transthoracic echocardiography at the authors' institution. Altogether, four patients with severe AS by live 3D TTE, and subsequently confirmed at surgery, were misdiagnosed as having moderate AS by two-dimensional transthoracic echocardiography. Because it is completely noninvasive and views the aortic valve in three dimensions, 3D TTE could be a useful complement to the existing modalities in the evaluation of AS severity.
Collapse
Affiliation(s)
- Srinivas Vengala
- Division of Cardiovascular, The University of Alabama at Birmingham, Birmingham, AL 35249, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Lang RM, Mor-Avi V, Sugeng L, Nieman PS, Sahn DJ. Three-Dimensional Echocardiography. J Am Coll Cardiol 2006; 48:2053-69. [PMID: 17112995 DOI: 10.1016/j.jacc.2006.07.047] [Citation(s) in RCA: 177] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2006] [Revised: 07/06/2006] [Accepted: 07/10/2006] [Indexed: 10/24/2022]
Abstract
Over the past 3 decades, echocardiography has become a major diagnostic tool in the arsenal of clinical cardiology for real-time imaging of cardiac dynamics. More and more, cardiologists' decisions are based on images created from ultrasound wave reflections. From the time ultrasound imaging technology provided the first insight into the human heart, our diagnostic capabilities have increased exponentially as a result of our growing knowledge and developing technology. One of the most significant developments of the last decades was the introduction of 3-dimensional (3D) imaging and its evolution from slow and labor-intense off-line reconstruction to real-time volumetric imaging. While continuing its meteoric rise instigated by constant technological refinements and continuing increase in computing power, this tool is guaranteed to be integrated in routine clinical practice. The major proven advantage of this technique is the improvement in the accuracy of the echocardiographic evaluation of cardiac chamber volumes, which is achieved by eliminating the need for geometric modeling and the errors caused by foreshortened views. Another benefit of 3D imaging is the realistic and unique comprehensive views of cardiac valves and congenital abnormalities. In addition, 3D imaging is extremely useful in the intraoperative and postoperative settings because it allows immediate feedback on the effectiveness of surgical interventions. In this article, we review the published reports that have provided the scientific basis for the clinical use of 3D ultrasound imaging of the heart and discuss its potential future applications.
Collapse
Affiliation(s)
- Roberto M Lang
- Cardiac Imaging Center, Department of Medicine, University of Chicago, Chicago, Illinois 60637, USA.
| | | | | | | | | |
Collapse
|
14
|
Poutanen T, Tikanoja T, Sairanen H, Jokinen E. Normal mitral and aortic valve areas assessed by three- and two-dimensional echocardiography in 168 children and young adults. Pediatr Cardiol 2006; 27:217-25. [PMID: 16193375 DOI: 10.1007/s00246-005-1056-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Our purpose was to investigate the effects of body size on the sizes of mitral (MV) and aortic valve (AV) areas by three-dimensional (3-D) and two-dimensional (2-D) echocardiography and to create the normal values for 3-D echocardiography. A total of 168 healthy subjects aged 2-27 years were studied by digitized 3-DE, 2-DE, and Doppler echocardiography.3-D echocardiography was performed by using rotational acquisition of planes at 18 degrees intervals from a parasternal view with electrocardiogram gating and without respiratory gating. The annular levels of MV and AV were identified from short-axis cut planes and their areas were measured by planimetry. The diameters of mitral annulus, left ventricular outflow tract (LVOT), and aortic annulus were measured by 2-DE from the apical and parasternal long-axis views. Flow indices were measured by Doppler from MV inflow and the flow in LVOT and in the ascending aorta. Both MV and AV annular areas increased linearly in relation to body size. In the total study group the estimated areas for MV were 5.2 +/- 0.9 cm2/m2 by 3-DE, 3.7 +/- 0.5 cm2/m2 by 2-DE, and 2.0 +/- 0.4 cm2/m2 by continuity equation. The respective values for AV were 2.7 +/- 0.5, 2.1 +/- 0.3, and 1.8 +/- 0.4 cm2/m2. MV velocity time integral (VTI)/ascending aorta VTI increased from 0.80 (0.26) to 0.95 (0.23) with increased body surface area (BSA), whereas MV VTI/LVOT VTI was 1.2 (0.2) in all BSA groups. MV and AV annulus areas increase linearly in relation to body size. 3-DE gives greater estimates for the areas than 2-DE and Doppler equation methods. The data obtained from 168 healthy subjects may serve as a reference for clinical use in patients with various cardiac abnormalities.
Collapse
Affiliation(s)
- T Poutanen
- Department of Pediatrics, Kuopio University Hospital, Kuopio, Finland.
| | | | | | | |
Collapse
|
15
|
Sugeng L, Weinert L, Thiele K, Lang RM. Real-Time Three-Dimensional Echocardiography Using a Novel Matrix Array Transducer. Echocardiography 2003; 20:623-35. [PMID: 14536013 DOI: 10.1046/j.1540-8175.2003.t01-1-03031.x] [Citation(s) in RCA: 79] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Three-dimensional echocardiography has multiple advantages over two-dimensional echocardiography, such as accurate left ventricular quantification and improved spatial relationships. However, clinical use of three-dimensional echocardiography has been impeded by tedious and time-consuming methods for data acquisition and post-processing. A newly developed matrix array probe, which allows real-time three-dimensional imaging with instantaneous on-line volume-rendered reconstruction, direct manipulation of thresholding, and cut planes on the ultrasound unit may overcome the aforementioned limitations. This report will review current methods of three-dimensional data acquisition, emphasizing the real-time methods and clinical applications of the new matrix array probe.
Collapse
Affiliation(s)
- Lissa Sugeng
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, Chicago, Illinois 60637, USA.
| | | | | | | |
Collapse
|
16
|
Handke M, Heinrichs G, Beyersdorf F, Olschewski M, Bode C, Geibel A. In vivo analysis of aortic valve dynamics by transesophageal 3-dimensional echocardiography with high temporal resolution. J Thorac Cardiovasc Surg 2003; 125:1412-9. [PMID: 12830062 DOI: 10.1016/s0022-5223(02)73604-0] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES Knowledge of aortic valve function has been obtained from experimental studies. The aim of the present study was to investigate characteristics of aortic valve motion in humans. METHODS Fifty-six patients were studied: 19 with normal valve and good systolic left ventricular function (Group NL), 12 with normal valve and reduced left ventricular function (Group CMP), and 25 with aortic stenosis and good left ventricular function (Group AS). The frame rate was doubled (50 Hz) compared with previous 3-dimensional systems. A mean of 38 +/- 9 images were acquired per cardiac cycle, with 14 +/- 4 images during the systole. The changes in shape and orifice area were analyzed over time. RESULTS With normal valves, valve movement proceeded in 3 phases: rapid opening, slow closing, rapid closing. Stenotic valves showed a slower opening and closing movement. The times to maximum opening in Groups NL, CMP, AS were 76 +/- 30, 88 +/- 18 (P =.06), and 130 +/- 29 (P <.01) ms, respectively. It was inversely correlated to the maximum orifice area (r = -0.59, P <.001). The opening velocities in Groups NL, CMP, AS were 42 +/- 23, 28 +/- 9 (P <.05), and 5 +/- 2 (P <.001) cm(2)/s, respectively. There was a close correlation between the opening velocity and the maximum orifice area (r = 0.87, P <.001). Slow valve closings occurred at a velocity of 8.0 +/- 5.2, 5.3 +/- 2.0 (P =.21), 2.8 +/- 1.1 (P <.01) cm(2)/s, respectively, and rapid closings in Groups NL and CMP at 50 +/- 23, 29 +/- 8 (P <.01) cm(2)/s. The results show good agreement with experimental data. CONCLUSION Rapid aortic valve movement can be recorded by 3-dimensional echocardiography and analyzed quantitatively. Time and velocity indices of valve dynamics are influenced by valvular and myocardial factors. A comparable in vivo analysis is not possible with any other imaging procedure.
Collapse
Affiliation(s)
- Michael Handke
- Department of Cardiology and Angiology, Albert-Ludwigs-University, Freiburg, Germany.
| | | | | | | | | | | |
Collapse
|
17
|
Dod HS, Nanda NC, Agrawal GG, Ravi BS, Htay T, Upendram SK. Three-dimensional transesophageal echocardiographic assessment of aortic valve pathology. THE AMERICAN JOURNAL OF GERIATRIC CARDIOLOGY 2003; 12:209-13. [PMID: 12732819 DOI: 10.1111/j.1076-7460.2003.02375.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Harvinder S Dod
- Division of Cardiovascular Disease, The University of Alabama at Birmingham, Birmingham, AL 35249, USA
| | | | | | | | | | | |
Collapse
|
18
|
Lange A, Palka P, Burstow DJ, Godman MJ. Three-dimensional echocardiography: historical development and current applications. J Am Soc Echocardiogr 2001; 14:403-12. [PMID: 11337688 DOI: 10.1067/mje.2001.113147] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Three-dimensional (3D) echocardiography facilitates spatial recognition of intracardiac structures, potentially enhancing diagnostic confidence of conventional echocardiography. The accuracy of 3D images has been validated in vitro and in vivo. In vitro, a detail 1.0 mm in dimension and 2 details separated by 1.0 mm can be identified from a volume-rendered 3D image. In vitro 3D volume measurements are underestimated by approximately 4.0 mL. In vivo, left ventricular volume measurements correlate highly with both cineventriculography (limits of agreement +/-18 mL for end diastole and +/-10 mL for end systole) and magnetic resonance imaging, including measurements for patients with functionally single ventricles. Studies on congenital heart lesions have shown good accuracy and good reproducibility of dynamic "surgical" reconstructions of septal defects, aortoseptal continuity, atrioventricular junction, and both left and right ventricular outflow tract morphology. Transthoracic 3D echocardiography was shown feasible in 81% to 96% of patients with congenital heart defects and provided additional information to that available from conventional echocardiography in 36% of patients, mainly in more detailed description of mitral valve morphology, aortoseptal continuity, and atrial septum. In patients with mitral valve insufficiency, 3D echocardiography was shown to be accurate in the quantification of the dynamic mechanism of mitral regurgitation and in the assessment of mitral commissures in patients with mitral stenosis. This includes not only valve tissue reconstruction but also color flow intracardiac jets. Three-dimensional reconstructions of the aortic valve were achieved in 77% of patients, with an accuracy of 90%. In conclusion, the role of 3D echocardiography, which continues to evolve, shows promise in the assessment of congenital and acquired heart disease.
Collapse
Affiliation(s)
- A Lange
- Department of Cardiology, The Prince Charles Hospital, Chermside, Brisbane, Australia.
| | | | | | | |
Collapse
|
19
|
Mele D, Levine RA. Quantitation of ventricular size and function: principles and accuracy of transthoracic rotational scanning. Echocardiography 2000; 17:749-55. [PMID: 11153026 DOI: 10.1111/j.1540-8175.2000.tb01233.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Two-dimensional echocardiography is a readily applicable method for the quantification of ventricular volumes. However, it is limited by assumptions regarding ventricular shape. Three-dimensional echocardiography has emerged as a more accurate and reproducible approach to ventricular volume and functional assessment compared with two-dimensional echocardiography. We review the principles of transthoracic rotational scanning and its clinical application for quantitative assessment of ventricular volume and function.
Collapse
Affiliation(s)
- D Mele
- Division of Cardiology, Arcíspedale S. Anna-University of Ferrara, Italy
| | | |
Collapse
|
20
|
Lange A, Mankad P, Walayat M, Palka P, Burns JE, Godman MJ. Transthoracic three-dimensional echocardiography in the preoperative assessment of atrioventricular septal defect morphology. Am J Cardiol 2000; 85:630-5. [PMID: 11078279 DOI: 10.1016/s0002-9149(99)00823-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A prospective study of 3-dimensional (3-D) transthoracic echocardiographic definition of atrioventricular septal defect (AVSD) morphology and its dynamic changes during the cardiac cycle was performed. The information obtained from 2-D and 3-D transthoracic echocardiography (TTE) was compared with intraoperative findings in an unselected group of 15 patients with AVSD (median age 22 months). In all study patients, 3-D reconstructions provided anatomic views of the atrioventricular valve(s) en face from either atrial or ventricular perspectives that allowed comprehensive assessment of dynamic valve morphology and the mechanism of valve reflux. Left-sided valve function was correctly assessed by 2-D TTE in 11 of 15 patients (73%) and in 14 of 15 (93%) by 3-D TTE. In 6 of 15 patients (40%), the severity of right-sided valve reflux was described precisely by 2-D TTE and in 12 of 15 patients (80%) by 3-D TTE. Additionally, 3-D TTE supplemented the diagnostic information to that available from 2-D TTE on atrial and ventricular septal defects. Although primum atrial septal defects were depicted by 2-D and 3-D TTE in all 15 patients, the description of defect size was more precise by the 3-D TTE (80% vs. 100%, respectively). The presence of secundum atrial septal defect was correctly diagnosed by both TTE techniques in 10 of 15 patients. Disagreement regarding the size of the defect was present only in 2 of 10 patients by 2-D TTE. In another 2 patients, 3-D TTE described multiple defect fenestrations that were missed by 2-D TTE. Thus, the agreement score was 73% for 2-D and 100% for 3-D echo. The agreement for the presence and sizing of ventricular septal defects was 67% for 2-D and 93% for 3-D echo. We conclude that 3-D TTE provided accurate anatomic reconstructions of the common atrioventricular junction and that the use of dynamic 3-D TTE enhanced the anatomic diagnostic capability of standard 2-D TTE. Medica, Inc.
Collapse
Affiliation(s)
- A Lange
- Department of Cardiology, Royal Hospital for Sick Children, Edinburgh, Scotland.
| | | | | | | | | | | |
Collapse
|
21
|
Dall'Agata A, Cromme-Dijkhuis AH, Meijboom FJ, Spitaels SE, McGhie JS, Roelandt JR, Bogers AJ. Use of three-dimensional echocardiography for analysis of outflow obstruction in congenital heart disease. Am J Cardiol 1999; 83:921-5. [PMID: 10190410 DOI: 10.1016/s0002-9149(98)01061-3] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
To evaluate the feasibility and accuracy of 3-dimensional (3D) echocardiography in analysis of left and right ventricular outflow tract (LVOT and RVOT) obstruction, 3D echocardiography was performed in 28 patients (age 4 months to 36 years) with outflow tract pathology. Type of lesion and relation to valves were assessed. Length and degree of obstruction were measured. Three-D data sets were adequate for reconstruction in 25 of 28 patients; 47 reconstructions were made. In 13 patients with LVOT obstruction, 3D echocardiography was used to study subvalvular details in 8, valvular in 13, and supravalvular in 1. Four of these 13 patients had complex subaortic obstruction. In 12 patients with RVOT lesions, 3D echocardiography was used to study subvalvular details in 11, valvular in 12, and supravalvular in 2. Three-dimensional reconstructions were suitable for analysis in 100% of subvalvular LVOT, 77% valvular LVOT, 100% supravalvular LVOT, 100% subvalvular RVOT, 50% valvular RVOT, and 50% supravalvular RVOT. Twenty patients underwent operation, and surgical findings served as morphologic control for thirty-four 3D reconstructions (LVOT 17, RVOT 17). Operative findings revealed an accuracy at subvalvular LVOT of 100%, valvular LVOT 90%, supravalvular LVOT 100%, subvalvular RVOT 100%, valvular RVOT 100%, and supravalvular RVOT 100%. Quantitative measurements could adequately be performed. Three-D echocardiography is feasible and accurate for analyzing both outflow tracts of the heart. Particularly, generation of nonconventional horizontal cross sections allows a good definition of extension and severity of lesions.
Collapse
Affiliation(s)
- A Dall'Agata
- Department of Cardiothoracic Surgery, Erasmus Medical Center Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
22
|
Kasprzak JD, Nosir YF, Dall'Agata A, Elhendy A, Taams M, Ten Cate FJ, Roelandt JR. Quantification of the aortic valve area in three-dimensional echocardiographic data sets: analysis of orifice overestimation resulting from suboptimal cut-plane selection. Am Heart J 1998; 135:995-1003. [PMID: 9630103 DOI: 10.1016/s0002-8703(98)70064-x] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Our study was designed to determine the feasibility of three-dimensional echocardiographic (3DE) aortic valve area planimetry and to evaluate potential errors resulting from suboptimal imaging plane position. METHODS AND RESULTS Transesophageal echocardiography with acquisition of images for 3DE was performed in 27 patients. Aortic valve orifice was planimetered in two-dimensional echocardiograms (2DE) and in two-dimensional views reconstructed from 3DE data sets optimized for the level of the cusp tips. To evaluate the errors caused by suboptimal cut-plane selection, orifice was also measured in cut-planes angulated by 10, 20, and 30 degrees or shifted by 1.5 to 7.5 mm. Planimetered orifice areas was similar in 2DE and 3DE studies: 2.09 +/- 0.97 cm2 versus 2.07 +/- 0.92 cm2. Significant overestimation was observed with cut-plane angulation (0.09, 0.19, and 0.34 cm2 at 10 degree increments) or parallel shift (0.11, 0.22, 0.33, 0.43, and 0.63 cm2 at 1.5 mm increments). Three-dimensional echocardiographic measurement reproducibility was very low and superior to that of 2DE. CONCLUSIONS Three-dimensional echocardiography allows accurate aortic valve area quantification with excellent reproducibility. Relatively small inaccuracy in cut-plane adjustment is a major source of errors in aortic valve area planimetry.
Collapse
Affiliation(s)
- J D Kasprzak
- Thoraxcenter, Division of Cardiology, Erasmus University and University Hospital Rotterdam-Dijkzigt, Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|