1
|
Gicana KRB, Pinidmontree C, Kosalathip K, Sirirut S, Komolvanich S, Asawakarn S, Sakcamduang W, Naiyanetr P, Tachampa K. Use of proposed systolic and myocardial performance indices derived from simultaneous ECG and PCG recordings to assess cardiac function in healthy Beagles. Vet World 2022; 15:1785-1797. [PMID: 36185531 PMCID: PMC9394128 DOI: 10.14202/vetworld.2022.1785-1797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Accepted: 06/07/2022] [Indexed: 11/16/2022] Open
Abstract
Background and Aim: Cardiac time intervals (CTIs) can provide important information on the electrical and mechanical properties of the heart. We hypothesized that cardiac function can be described using the combined power of electrocardiography (ECG) and phonocardiography (PCG) signals. This study aimed to (1) validate a novel custom device in measuring CTI parameters; (2) compare CTI parameters with a commercially available device and standard transthoracic echocardiography (STE); and (3) compare calculated systolic performance index (SPI) and myocardial performance index (MPI) with Tei index from the STE. Materials and Methods: This study determined CTIs based on simultaneous ECG and PCG recordings in 14 healthy Beagle dogs using the custom-built device. These CTI parameters were compared with a commercially available device (Eko DUO ECG + Digital Stethoscope; Eko DUO) and the STE. Agreement of CTI parameters between the custom device and the commercially available device or STE was evaluated. Calculated SPI and MPI based on Wigger’s diagram were proposed, compared with SPI and Tei index, and correlated with STE parameters. Results: We found that the ECG and PCG parameters measured from the custom-built device did not differ from the commercially available device and the STE. By combining ECG and PCG signals, we established CTI parameters in healthy dogs including indices for systolic function (SPI: QS1/S1S2) and global cardiac function {F1 ([QS1+S2]/S1S2), F2 ([RS1+S2]/S1S2), and F3 (RS1 + [QS2-QT]/S1S2)}. The SPI, F2, and F3 were comparable with echocardiographic parameters describing systolic (Pre-ejection period/left ventricular ejection time [LVET]) and Tei index ([MCOdur-LVET]/LVET), respectively. Only SPI and F3 were correlated significantly with MCOdur and heart rate, respectively. Conclusion: We have validated the use of the custom-built device to describe CTIs that are comparable to the commercially available device and STE in healthy Beagles. The proposed SPI and MPI derived from CTI parameters can be useful in clinical practice to describe the cardiac function, especially in areas where access to STE is constrained.
Collapse
Affiliation(s)
- Karlo Romano B. Gicana
- The International Graduate Program of Veterinary Science and Technology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, University of the Philippines Los Baños, Laguna, Philippines
| | - Chirutchaya Pinidmontree
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand
| | - Kitchanan Kosalathip
- Cardiovascular Engineering and Artificial Organs (CardioArt) Laboratory, Department of Biomedical Engineering Department, Mahidol University, Nakhon Pathom, Thailand
| | - Siraphop Sirirut
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand
| | - Siripen Komolvanich
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand
| | - Sariya Asawakarn
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand; Biomarkers in Animal Parasitology Research Group, Chulalongkorn University, Bangkok, Thailand
| | - Walasinee Sakcamduang
- Department of Clinical Sciences and Public Health, Faculty of Veterinary Science, Mahidol University, Nakhon Pathom, Thailand
| | - Phornphop Naiyanetr
- Cardiovascular Engineering and Artificial Organs (CardioArt) Laboratory, Department of Biomedical Engineering Department, Mahidol University, Nakhon Pathom, Thailand
| | - Kittipong Tachampa
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand; Biomarkers in Animal Parasitology Research Group, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
2
|
Gicana KRB, Lertwanakarn T, Tachampa K. Novel Approach to Assess Cardiac Function Using Systolic Performance and Myocardial Performance Indices From Simultaneous Electrocardiography and Phonocardiography Recordings in Dogs With Various Stages of Myxomatous Mitral Valve Disease. Front Vet Sci 2021; 8:741115. [PMID: 34746282 PMCID: PMC8566337 DOI: 10.3389/fvets.2021.741115] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 09/20/2021] [Indexed: 11/13/2022] Open
Abstract
Background and Objective: Myxomatous mitral valve disease (MMVD) progression entails changes in the structural and functional properties of the heart affecting cardiac timings and intervals within the cardiac cycle. Conventionally, echocardiography is used to determine the cardiac time intervals (CTIs) including systolic and myocardial performance indices (SPI and MPI) in evaluating cardiac function. Alternatively, these CTIs can also be measured using simultaneous recordings of electrocardiography (ECG) and phonocardiography (PCG), but their values in different MMVD stages remain to be established. This study aimed to establish and prove the use of derived SPI and MPI from a dedicated device as a novel approach to assess cardiac function in different stages of MMVD dogs. Materials and Methods: A prospective study in 52 dogs with different MMVD stages measured the CTIs using a novel device. These were compared and correlated with standard echocardiographic parameters. The predictive value of SPI and three new proposed formulas to estimate MPI (i.e., F1, F2, and F3) in association with asymptomatic from symptomatic MMVD dogs were investigated. Results: Our findings revealed that CTI parameters measured from a novel device including QS1, QS2, S1S2, MPI-F1, and MPI-F2 were altered at different stages of MMVD. The SPI and all proposed MPI formulas were comparable with the systolic time interval and Tei index from echocardiography. In addition, the SPI, MPI-F1, and MPI-F2 were significantly correlated with the Tei index. However, the SPI was not able to differentiate the various stages of MMVD. Conversely, only the MPI-F1 (i.e., (QS1 + S2)/S1S2) demonstrated good predictive accuracy when compared between asymptomatic and symptomatic MMVD dogs similar to the Tei index. Moreover, this formula was able to differentiate stages B1 and C with remarkable predictive accuracy, higher sensitivity, and high specificity when compared with the Tei index. Conclusion: We have successfully described the CTI parameters in different MMVD stages using simultaneous ECG and PCG recordings in dogs. Furthermore, we have proven that the concept of using the newly proposed parameters from a novel device is equivalent to the Tei index. Thus, we established a novel approach to evaluate cardiac function and its supportive use in the diagnosis of MMVD patients.
Collapse
Affiliation(s)
- Karlo Romano B Gicana
- The International Graduate Program of Veterinary Science and Technology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.,Department of Veterinary Clinical Sciences, College of Veterinary Medicine, University of the Philippines Los Baños, Los Baños, Philippines
| | - Tuchakorn Lertwanakarn
- Department of Physiology, Faculty of Veterinary Medicine, Kasetsart University, Bangkok, Thailand
| | - Kittipong Tachampa
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
3
|
Topyła-Putowska W, Tomaszewski M, Wysokiński A, Tomaszewski A. Echocardiography in Pulmonary Arterial Hypertension: Comprehensive Evaluation and Technical Considerations. J Clin Med 2021; 10:jcm10153229. [PMID: 34362015 PMCID: PMC8348437 DOI: 10.3390/jcm10153229] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 07/18/2021] [Accepted: 07/20/2021] [Indexed: 12/21/2022] Open
Abstract
Pulmonary arterial hypertension (PAH) is a rare, progressive disease in which there is a persistent, abnormal increase in pulmonary artery pressure. Symptoms of pulmonary hypertension are nonspecific and mainly associated with progressive right ventricular failure. The diagnosis of PAH is a multistep process and often requires the skillful use of several tests. The gold standard for the diagnosis of PAH is hemodynamic testing. Echocardiography currently plays an important role in the diagnostic algorithm of PAH as it is minimally invasive and readily available. Moreover, many echocardiographic parameters are closely related to pulmonary hemodynamics. It allows assessment of the right heart′s structure and function, estimation of the pressure in the right ventricle, right atrium, and pulmonary trunk, and exclusion of other causes of elevated pulmonary bed pressure. Echocardiographic techniques are constantly evolving, and recently, measurements made using new techniques, especially 3D visualization, have become increasingly important. In echocardiographic assessment, it is crucial to know current guidelines and new reports that organize the methodology and allow standardization of the examination. This review aims to discuss the different echocardiographic techniques used to evaluate patients with PAH.
Collapse
|
4
|
Nagai T, Horinouchi H, Ohno Y, Murakami T, Sakai K, Nakazawa G, Yoshioka K, Ikari Y. Predictors for non-delayed discharge after transcatheter aortic valve replacement: utility of echocardiographic parameters. Int J Cardiovasc Imaging 2020; 37:47-58. [PMID: 32712734 DOI: 10.1007/s10554-020-01944-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 07/20/2020] [Indexed: 10/23/2022]
Abstract
Considering that transcatheter aortic valve replacement (TAVR) procedures have become less invasive, the duration for monitoring patient care after a successful TAVR can be reduced. Therefore, this study aimed to investigate the prognostic value of baseline echocardiographic parameters for non-delayed discharge in patients after TAVR. The study group included 154 consecutive patients (mean age: 84.4 ± 4.5 years; and 101 women) who underwent a TAVR. Comprehensive echocardiograms including both side indices of myocardial performance (IMP) and blood tests were obtained prior to the TAVR procedure. The median post-TAVR length of stay was 6 days while the mode and first quartile were both 4 days. Receiver operating characteristic curve analysis showed that the optimum cut-off value of the left-sided IMP in patients with a normal left ventricular ejection fraction (LVEF, ≥ 50%) (n = 124) for non-delayed discharge (≤ 4 days) was 0.34 with an area under the curve (AUC) value of 0.71563 and p value of < 0.0001, while the optimum cut-off value in patients with reduced LVEF (< 50%) (n = 30) was 0.47 with an AUC value of 0.77778 and p value of < 0.0120. An adjusted analysis indicated the negative left-sided IMP results as the only predictor for non-delayed discharge (p < 0.0001). Furthermore, the adjusted predictors for survival without early cardiovascular re-hospitalization within 6 months after TAVR were the positive left-sided IMP result, when the cut-off value of 0.52 was used, and the presence of elevated RAP of 8 to 15 mmHg. The early discharge policy should be carefully considered in high-risk populations, but the left-sided IMP may play a significant role in the pre-screening process.
Collapse
Affiliation(s)
- Tomoo Nagai
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan.
| | - Hitomi Horinouchi
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan
| | - Yohei Ohno
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan
| | - Tsutomu Murakami
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan
| | - Katsuaki Sakai
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan
| | - Gaku Nakazawa
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan
| | - Koichiro Yoshioka
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan
| | - Yuji Ikari
- Division of Cardiovascular Medicine, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara-shi, Kanagawa, 259-1193, Japan
| |
Collapse
|
5
|
A novel index equivalent to the myocardial performance index for right ventricular functional assessment in children and adolescent patients. Sci Rep 2019; 9:19975. [PMID: 31882794 PMCID: PMC6934714 DOI: 10.1038/s41598-019-56564-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Accepted: 12/13/2019] [Indexed: 11/19/2022] Open
Abstract
The aims of the present study were to develop and check the utility and feasibility of a novel right ventricular (RV) functional index (RV angular velocity; RVω, s−1) derived from the angular velocity in harmonic oscillator kinematics obtained from the RV pressure waveform. We hypothesized that RVω reflects the myocardial performance index (MPI), which represents global RV function. A total of 132 consecutive patients, ranging in age from 3 months to 34 years with various cardiac diseases were included in this prospective study. RVω was defined as the difference between the peak derivative of pressure (dP/dt_max − dP/dt_min) divided by the difference between the maximum and minimum pressure (Pmax – Pmin). RVω showed significant negative correlations with the pulsed-wave Doppler-derived myocardial performance index (PWD-MPI) and the tissue Doppler imaging-derived MPI (TDI-MPI) (r = −0.52 and −0.51, respectively; both p < 0.0001). RVω also showed significant positive correlations with RV fractional area change (RVFAC) and RV ejection fraction (RVEF) (r = 0.41 and 0.39, respectively; both p < 0.0001), as well as a significant negative correlation with tricuspid E/e′ (r = −0.19, p = 0.0283). The clinical feasibility and utility of RVω for assessing global RV performance, incorporating both systolic and diastolic function, were demonstrated.
Collapse
|
6
|
Al-Daydamony MM, El-Tahlawi MA, Shawky A. Can myocardial performance index predict the presence of silent ischemia in asymptomatic type 2 diabetic patients? Echocardiography 2016; 33:1823-1827. [PMID: 27677770 DOI: 10.1111/echo.13359] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Coronary artery disease (CAD) is an important cause of morbidity and mortality in patients with diabetes. Silent myocardial ischemia (SMI) is common in patients with diabetes and is associated with poorer prognosis. Myocardial performance index "Tei index" that reflects both left ventricular (LV) systolic and diastolic function. The aim of our study was to test the value of Tei index in prediction of SMI in asymptomatic patients with type 2 diabetes. PATIENTS AND METHODS Asymptomatic patients with type 2 diabetes were included in our study. We excluded patients with known CAD, previous revascularization, low ejection fraction, or abnormal ECG from the study. All patients had undergone history taking and clinical examination, ECG, echocardiography with measuring of Tei index and Holter monitoring for detecting silent ischemia. RESULTS A total of 200 patients were recruited. We divided our patients into two groups: Group I: 64 patients with SMI, Group II: 136 patients without SMI. There was no significant difference between the two groups regarding clinical and conventional echocardiographic data. Tei index was significantly higher in patients with silent ischemia (P<.00001). Sensitivity, specificity, positive, and negative predictive values of Tei index ≥0.6 in prediction of Holter detected silent ischemia were 85.9%, 90%, 78.6%, and 88.6%, respectively. We found a significant positive correlation between Tei index and number of ischemic episodes (r=.366, P=.0029). CONCLUSION Measuring Tei index is helpful in predicting the presence of silent ischemia in asymptomatic patients with type 2 diabetes.
Collapse
Affiliation(s)
| | | | - Ahmad Shawky
- Cardiology Department, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| |
Collapse
|
7
|
Godfrey ME, Messing B, Cohen SM, Valsky DV, Yagel S. Functional assessment of the fetal heart: a review. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2012; 39:131-144. [PMID: 21611999 DOI: 10.1002/uog.9064] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/12/2011] [Indexed: 05/30/2023]
Abstract
The purpose of this review is to evaluate the current modalities available for the assessment of fetal cardiac function. The unique anatomy and physiology of the fetal circulation are described, with reference to the difference between in-utero and ex-utero life. M-mode, early/atrial ratio, myocardial performance index, three-dimensional and four-dimensional ultrasound, tissue Doppler including strain and strain rate, speckle tracking, magnetic resonance imaging and venous flow assessment are described. The modalities are analyzed from the perspective of the clinician and certain questions are posed. Does the modality assess systolic function, diastolic function or both? Is it applicable to both ventricles? Does it require extensive post-processing or additional hardware, or does it make use of technology already available to the average practitioner? The reproducibility and reliability of the techniques are evaluated, with reference to their utility in clinical decision-making. Finally, directions for future research are proposed.
Collapse
Affiliation(s)
- M E Godfrey
- Department of Pediatric Cardiology, Schneider Children's Medical Center Israel, Petach Tikva, Israel
| | | | | | | | | |
Collapse
|
8
|
Shingu Y, Amorim P, Nguyen TD, Mohr FW, Schwarzer M, Doenst T. Myocardial performance (Tei) index is normal in diastolic and systolic heart failure induced by pressure overload in rats. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2010; 11:829-33. [DOI: 10.1093/ejechocard/jeq077] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|