Kang SJ, Park DW, Mintz GS, Lee SW, Kim YH, Lee CW, Han KH, Kim JJ, Park SW, Park SJ. Long-term vascular changes after drug-eluting stent implantation assessed by serial volumetric intravascular ultrasound analysis.
Am J Cardiol 2010;
105:1402-8. [PMID:
20451685 DOI:
10.1016/j.amjcard.2009.12.064]
[Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2009] [Revised: 12/22/2009] [Accepted: 12/22/2009] [Indexed: 10/19/2022]
Abstract
Using serial volumetric intravascular ultrasonography, we evaluated the predictors of late intimal hyperplasia (IH) increases after drug-eluting stent implantation. All eligible patients who underwent 6-month angiography without visual restenosis were requested to undergo a 2-year follow-up examination. Complete serial (after stenting and early [6-month], and late [2-year] follow-up) angiographic and intravascular ultrasound data were available for 135 patients with 143 lesions: 99 sirolimus-eluting stents and 44 paclitaxel-eluting stents. The external elastic membrane, stent, lumen, and peri-stent plaque volumes (external elastic membrane minus stent) were normalized by stent length. The percentage of IH volume was calculated as IH volume/stent volume x 100. The early reduction in the minimum lumen area was greater than the late reduction in the minimum lumen area (-0.8 +/- 0.8 vs -0.2 +/- 0.5 mm(2), p <0.001). A progressive increase occurred in the percentage of IH volume: 8.1 +/- 7.1% from baseline to 6 months and 2.4 +/- 3.9% from 6 months to 2 years (p <0.001, between the early and late increases in the percentage of IH). The use of paclitaxel-eluting stents was the only independent predictor for the percentage of IH volume at 6 months (beta = 0.419, p <0.001). The use of paclitaxel-eluting stents (beta = 0.365, p <0.001, 95% confidence interval 3.7 to 9.7) and the post-stenting normalized plaque and media volume (beta = 0.195, p = 0.020, 95% confidence interval 0.1 to 1.6) were the only independent predictors for the percentage of IH volume at 2 years. However, when the percentage of IH at 6 months was forced into the model, the percentage of IH at 6 months and the post-stenting normalized plaque and media volume, not paclitaxel-eluting stent use, predicted the 2-year percentage of IH. In conclusion, although IH continued to increase beyond 6 months, the growth rate of intima and luminal loss attenuated with time.
Collapse