1
|
Pierard LA. Measure or predict prosthesis-patient mismatch? Eur Heart J Cardiovasc Imaging 2021; 22:21-23. [PMID: 33152078 DOI: 10.1093/ehjci/jeaa267] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 09/12/2020] [Indexed: 11/13/2022] Open
|
2
|
Silberman S, Oren A, Dotan M, Merin O, Fink D, Deeb M, Bitran D. Aortic valve replacement: choice between mechanical valves and bioprostheses. J Card Surg 2008; 23:299-306. [PMID: 18462345 DOI: 10.1111/j.1540-8191.2008.00580.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND The choice between a mechanical or bioprosthetic valve replacement device is not always clear, although patient age is most often the determining factor. We reviewed our experience with patients undergoing aortic valve replacement (AVR) in order to assess and compare long-term outcomes between patients receiving a mechanical valve and those receiving a bioprosthesis. METHODS Three hundred fifty-two patients underwent AVR with or without coronary artery bypass between 1993 and 2004: 189 received a mechanical valve and 163 a bioprosthesis. Events included: late mortality, thrombo-embolic events, stroke, bleeding events, valve thrombosis, endocarditis, reoperation, and coronary catheterization. RESULTS Patients in the bioprosthesis group were older (71 +/- 11 vs. 65 +/- 13) than in the mechanical group (p < 0.0001). There was no difference in operative mortality (6.8%) or morbidity. Follow-up (61 +/- 40 months) was available in 87%. For mechanical valves and bioprostheses, respectively: 3-, 5-, and 10-year survival was 92%, 86%, and 69% versus 90%, 86%, and 71% (p = n.s.); and event-free survival was 79%, 68%, and 41% versus 79%, 68%, and 44% (p = n.s.). Five patients (3%) in each group required re-replacement of their aortic valve (p = n.s.). Coronary artery disease requiring bypass surgery did not affect long-term survival. Age at operation and renal failure were the only predictors for late mortality. CONCLUSIONS Survival and event-free survival are similar for patients receiving a mechanical or biological aortic valve substitute. Selection of a valve replacement device should be based on life expectancy, patient preference, ability to take anticoagulants, lifestyle, risk of bleeding, and risk of reoperation. Patient age alone should not be the determining factor.
Collapse
Affiliation(s)
- Shuli Silberman
- Department of Cardiothoracic Surgery, Shaare Zedek Medical Center, Jerusalem, Israel.
| | | | | | | | | | | | | |
Collapse
|
3
|
Martinovic I, Everlien M, Farah I, Wittlinger T, Knez I, Greve H, Vogt P. Midterm Results After Aortic Valve Replacement With a Stentless Bioprosthesis Aortic Valve. Ann Thorac Surg 2005; 80:198-203. [PMID: 15975367 DOI: 10.1016/j.athoracsur.2005.01.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2004] [Revised: 01/04/2005] [Accepted: 01/07/2005] [Indexed: 10/25/2022]
Abstract
BACKGROUND It is suggested that a simplified implant model Cryolife-O'Brien (CryoLife International, Kennesaw, GA) offers less satisfactory outcome compared with standard stentless models. This study was conducted to prospectively evaluate the midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis. METHODS In 1996, a prospective clinical trial using different stentless valves was initiated. From September 1996 through September 2002, 156 consecutive patients with a mean age of 74.5 years underwent aortic valve replacement with the Cryolife-O'Brien porcine stentless bioprosthesis. The predominant aortic valve lesion was stenosis in 128 and insufficiency in 28 cases. Patients have been followed from 2 to 72 months (mean, 42 months). Echocardiography was performed by one echocardiographer preoperatively, intraoperatively, postoperatively at discharge, 2 to 6 months later, and annually thereafter. RESULTS Sixty percent of patients received a valve 25 mm in diameter or larger; 39% had concomittant coronary bypass grafting. The 30-day operative mortality rate was 6.4%. Ten late nonvalve-related deaths have occurred. Severe aortic insufficiency caused by oversizing leads to early reoperation in 3 patients. The peak and mean systolic gradients decreased significantly during the first 12 months after implantation, p < 0.001, and the effective valve areas increased significantly during this time interval p < 0.001. At 5 years, ten patients have moderate aortic insufficiency. The actuarial survival at 5 years was 88 +/- 3%. The rate for freedom from endocarditis was 100% and for freedom from thromboembolic events was 94%. CONCLUSIONS Midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis are encouraging. Good hemodynamics have been coupled with low rate of valve-related complications, thus representing a very good alternative to conventional stented bioprostheses.
Collapse
Affiliation(s)
- Ivo Martinovic
- Department of Cardiothoracic Surgery, Klinikum Krefeld, Krefeld, Germany.
| | | | | | | | | | | | | |
Collapse
|
4
|
Kon ND, Riley RD, Adair SM, Kitzman DW, Cordell AR. Eight-year results of aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis. Ann Thorac Surg 2002; 73:1817-21; discussion 1821. [PMID: 12078775 DOI: 10.1016/s0003-4975(02)03575-0] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Stentless porcine aortic valves offer several advantages over traditional valves. Among these are superior hemodynamics, laminar flow patterns, lack of need for anticoagulation, and perhaps improved durability. METHODS One hundred four patients were operated on from September 17, 1992, to October 31, 1997, as part of a multicenter worldwide investigation of the Medtronic Freestyle stentless porcine bioprosthesis. All patients received a total aortic root replacement. The patients were evaluated postoperatively at discharge, at 3 to 6 months, and yearly by clinical examination and color flow Doppler echocardiography. RESULTS Operative mortality was 3.9%. No patient experienced structural valve deterioration, nonstructural deterioration, perivalvular leak, or unacceptable hemodynamic performance. At 8 years, survival was 59.8%. Freedom from thromboembolic complications was 83.3%. Freedom from postoperative endocarditis was 96.9%. Freedom from reoperation was 100%. Mean systolic gradients did not change over the time period studied. They were 6.4 +/- 3.8 mm Hg at 1 year and 6.7 +/- 2.6 mm Hg at 8 years. Correspondingly, effective orifice area was 1.9 +/- 0.7 cm2 at 1 year and 1.8 +/- 0.8 cm2 at 8 years. The incidence of any aortic insufficiency also did not change over the length of follow-up. At 1 year, 98% of patients had no or trivial aortic insufficiency and 2% had mild aortic insufficiency. At 8 years, 100% of patients evaluated were free of any aortic insufficiency. CONCLUSIONS The Medtronic Freestyle aortic root bioprosthesis can be used safely to replace the aortic root or aortic valve for aortic valve and aortic root pathology. Total root replacement allows optimal hemodynamic performance with no significant aortic regurgitation. Results up to 8 years show excellent survival and no signs of degeneration. Further follow-up is still needed to determine valve durability.
Collapse
Affiliation(s)
- Neal D Kon
- Department of Cardiothoracic Surgery, Wake Forest University School of Medicine, Winston-Salem, North Carolina 27157-1096, USA.
| | | | | | | | | |
Collapse
|
5
|
Cohen G, Christakis GT, Joyner CD, Morgan CD, Tamariz M, Hanayama N, Mallidi H, Szalai JP, Katic M, Rao V, Fremes SE, Goldman BS. Are stentless valves hemodynamically superior to stented valves? A prospective randomized trial. Ann Thorac Surg 2002; 73:767-75; discussion 775-8. [PMID: 11899180 DOI: 10.1016/s0003-4975(01)03338-0] [Citation(s) in RCA: 89] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Although stentless aortic bioprostheses are believed to offer improved outcomes, hemodynamic benefits remain unsubstantiated. METHODS Fifty-three patients were randomized to receive the stented C-E pericardial valve (CE) and 46 patients the Toronto Stentless Porcine valve (SPV). Annuli were sized for the optimal insertion of both valve types, such that surgeons were required to commit to specific valve sizes before randomization. Echocardiographic measurements and functional status (Duke Activity Status Index) were assessed at 3 and 12 months postoperatively. RESULTS Although cardiopulmonary bypass times (CE: 118.6+/-36.3 minutes; SPV: 148.5+/-30.9 minutes; p = 0.0001) and aortic cross-clamp times (CE: 95.4+/-28.6 minutes; SPV: 123.6+/-24.1 minutes; p = 0.0001) were significantly prolonged in the SPV group, perioperative morbidity and mortality was similar between groups. Neither valve offered a superior internal diameter for any given annular diameter (mean decrease in left ventricular outflow tract diameter after valvular implantation: SPV: 3.4+/-1.11 mm versus CE: 3.7+/-1.33 mm; p = 0.25). Although labeled mean valve size was significantly larger in the SPV group, the actual mean valve size based on internal valvular diameter was no different between groups (CE: 21.9+/-2.0 mm; SPV: 22.3+/-2.0 mm; p = 0.286). Although effective orifice areas increased, and mean and peak transvalvular gradients decreased in both groups over time, no differences were demonstrated between groups at 12 months. Similarly, although significant regression of left ventricular mass was accomplished in both groups over time, no differences were demonstrated between groups. Finally, Duke Activity Status Index scores of functional status improved in both groups over time; however, no differences were noted between groups at 12 months postoperatively. CONCLUSIONS Although offering excellent outcomes, stentless valves did not demonstrate superior hemodynamic indices in comparison to stented valves up to 12 months after implantation.
Collapse
Affiliation(s)
- Gideon Cohen
- Division of Cardiovascular Surgery, Sunnybrook and Women's College Health Sciences Centre, University of Toronto, Ontario, Canada
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000; 36:1131-41. [PMID: 11028462 DOI: 10.1016/s0735-1097(00)00859-7] [Citation(s) in RCA: 415] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Prosthesis-patient mismatch is present when the effective orifice area of the inserted prosthetic valve is less than that of a normal human valve. This is a frequent problem in patients undergoing aortic valve replacement, and its main hemodynamic consequence is the generation of high transvalvular gradients through normally functioning prosthetic valves. The purposes of this report are to present an update on the concept of aortic prosthesis-patient mismatch and to review the present knowledge with regard to its impact on hemodynamic status, functional capacity, morbidity and mortality. Also, we propose a simple approach for the prevention and clinical management of this phenomenon because it can be largely avoided if certain simple factors are taken into consideration before the operation.
Collapse
Affiliation(s)
- P Pibarot
- Quebec Heart Institute/Laval Hospital, Laval University, Sainte-Foy, Canada
| | | |
Collapse
|
7
|
Fries R, Wendler O, Schieffer H, Schäfers HJ. Comparative rest and exercise hemodynamics of 23-mm stentless versus 23-mm stented aortic bioprostheses. Ann Thorac Surg 2000; 69:817-22. [PMID: 10750766 DOI: 10.1016/s0003-4975(99)01409-5] [Citation(s) in RCA: 64] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND The hemodynamic superiority of stentless valves at rest has been generally accepted, but there is a lack of studies on exercise hemodynamics. METHODS We assessed aortic valve hemodynamics at rest and during exercise in 10 patients with a 23-mm stentless aortic bioprosthesis (Medtronic Freestyle; Medtronic Europe SA/NV, St. Stevens Woluwe, Belgium), in 10 patients with a 23-mm stented aortic bioprosthesis (Carpentier-Edwards, SAV, model 2650; Baxter Edwards AG, Horw, Switzerland), and in 10 healthy volunteers (control group) by means of Doppler echocardiography. RESULTS Gradients at rest and gradients on comparable maximum exercise levels were significantly lower in patients with stentless valves compared to those with stented valves (rest: 6 +/- 2/11 +/- 4 mm Hg [mean/peak] versus 12 +/- 3/21 +/- 10 mm Hg; exercise: 9 +/- 3/18 +/- 6 mm Hg [mean/peak] versus 22 +/- 8/40 +/- 11 mm Hg). Patients with stentless valves revealed, in comparison to healthy young men, significantly higher gradients, but the small gradient difference of 3/7 mm Hg (mean/peak) at rest remained nearly unchanged throughout the exercise protocol (4/8 mm Hg [mean/peak] at 25 W, 4/9 mm Hg at 50 W and 4/9 mm Hg at 75 W). In contrast, the gradient difference between patients with stented and stentless valves increased significantly from one exercise level to the next (6/12 mm Hg [mean/peak] at rest, 8/14 mm Hg at 25 W, 12/17 mm Hg at 50 W, and 15/25 mm Hg at 75 W). CONCLUSIONS A stentless aortic bioprosthesis seems to be an appropriate aortic valve substitute, especially in patients who perform regular physical exercise.
Collapse
Affiliation(s)
- R Fries
- Department of Cardiology and Angiology, University Hospitals Homburg, Homburg/Saar, Germany.
| | | | | | | |
Collapse
|
8
|
Pibarot P, Dumesnil JG, Leblanc MH, Cartier P, Métras J. Changes in left ventricular mass and function after aortic valve replacement: a comparison between stentless and stented bioprosthetic valves. J Am Soc Echocardiogr 1999; 12:981-7. [PMID: 10552360 DOI: 10.1016/s0894-7317(99)70152-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to the postoperative changes in left ventricular (LV) mass and function. Forty patients with aortic stenosis undergoing valve replacement with a stentless (20 patients) or a stented (20 patients) bioprosthesis were evaluated early (baseline), 1 year, and 2 years after operation. Left ventricular mass index was calculated with the corrected American Society of Echocardiography formula. The relative changes between end-diastole and end-systole in LV mid-wall radius, length, and volume (ejection fraction) were determined with a previously validated model for dynamic geometry of the left ventricle. Overall, a significant decrease was found in LV mass index (from 155 +/- 30 to 112 +/- 23 g/m(2); P <.001) and a significant increase in longitudinal shortening (from 0.12 +/- 0.11 to 0.22 +/- 0.08; P <. 001), and ejection fractions (from 0.67 +/- 0.11 to 0.71 +/- 0.10; P =.017). No significant change was found in the mid-wall radius shortening fraction. Two years after surgery, the extent of LV mass regression was greater in stentless bioprostheses (-51 +/- 18 vs -35 +/- 17 g/m(2); P =.01), though the average mass index was similar in both groups (114 +/- 26 vs 110 +/- 20 g/m(2)). Also at 2 years, the longitudinal shortening fraction was greater in patients with a stentless bioprosthesis (0.25 +/- 0.07 vs 0.18 +/- 0.08; P =.03). In conclusion, this study suggests that the superior hemodynamic performance of stentless bioprostheses may have some benefits with regard to LV mass regression and function after aortic valve replacement. The significance of these benefits in terms of prognosis remains to be determined.
Collapse
Affiliation(s)
- P Pibarot
- Quebec Heart Institute/Laval Hospital, Department of Medicine, Laval University, Ste-Foy, Quebec, Canada.
| | | | | | | | | |
Collapse
|
9
|
Pibarot P, Dumesnil JG, Jobin J, Cartier P, Honos G, Durand LG. Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: comparison of stentless versus stented bioprostheses. J Am Coll Cardiol 1999; 34:1609-17. [PMID: 10551713 DOI: 10.1016/s0735-1097(99)00360-5] [Citation(s) in RCA: 96] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVES The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to their hemodynamic behavior during exercise. BACKGROUND Stentless aortic bioprostheses have better hemodynamic performances at rest than stented bioprostheses, but very few comparisons were performed during exercise. METHODS Thirty-eight patients with normally functioning stentless (n = 19) or stented (n = 19) bioprostheses were submitted to a maximal ramp upright bicycle exercise test. Valve effective orifice area and mean transvalvular pressure gradient at rest and during peak exercise were successfully measured using Doppler echocardiography in 30 of the 38 patients. RESULTS At peak exercise, the mean gradient increased significantly less in stentless than in stented bioprostheses (+5 +/- 3 vs. +12 +/- 8 mm Hg; p = 0.002) despite similar increases in mean flow rates (+137 +/- 58 vs. +125 +/- 65 ml/s; p = 0.58); valve area also increased but with no significant difference between groups. Despite this hemodynamic difference, exercise capacity was not significantly different, but left ventricular (LV) mass and function were closer to normal in stentless bioprostheses. Overall, there was a strong inverse relation between the mean gradient during peak exercise and the indexed valve area at rest (r = 0.90). CONCLUSIONS Hemodynamics during exercise are better in stentless than stented bioprostheses due to the larger resting indexed valve area of stentless bioprostheses. This is associated with beneficial effects with regard to LV mass and function. The relation found between the resting indexed valve area and the gradient during exercise can be used to project the hemodynamic behavior of these bioprostheses at the time of operation. It should thus be useful to select the optimal prosthesis given the patient's body surface area and level of physical activity.
Collapse
Affiliation(s)
- P Pibarot
- Quebec Heart Institute/Laval Hospital, Laval University, Ste-Foy, Quebec, Canada.
| | | | | | | | | | | |
Collapse
|
10
|
Baur LH, Jin XY, Houdas Y, Peels CH, Braun J, Kappetein AP, Prat A, Hazekamp MG, Van Straten BH, Ploeg A, Sieders A, Voogd PJ, Bruschke AV, van der Wall EE, Westaby S, Huysmans HA. Echocardiographic parameters of the freestyle stentless bioprosthesis in aortic position: the European experience. J Am Soc Echocardiogr 1999; 12:729-35. [PMID: 10477417 DOI: 10.1016/s0894-7317(99)70023-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The objective of this study was to determine normal Doppler and 2-dimensional characteristics of the Freestyle stentless aortic bioprosthesis. The Freestyle aortic bioprosthesis is a new type of aortic xenograft, and experience is limited. We therefore determined the normal range of echocardiographic and Doppler examinations of this valve. Three hundred thirty-nine consecutive patients with a Freestyle aortic bioprosthesis underwent an echocardiographic and Doppler examination according to a common protocol. Investigations were done within 4 weeks after operation, after 3 to 6 months, and after 1, 2, and 3 years. With a valve size from 19 to 27 mm, mean gradients decreased from 7.9 +/- 5.1 mm Hg at discharge to 5.5 +/- 3. 8 mm Hg after 3 to 6 months (P <.001). Thereafter, gradients remained stable. Effective orifice area 1 year after implantation was 1.59 +/- 0.58 cm(2) for the 21-mm valves, 1.92 +/- 0.74 cm(2) for the 23-mm valves, 2.03 +/- 0.64 cm(2) for the 25-mm valves, and 2.52 +/- 0.72 cm(2) for the 27-mm valves (P <.001). The performance index, the ratio of the measured effective orifice area in the patient divided by the effective orifice area measured in vitro, increased from 67% +/- 20% at discharge to 82% +/- 29% after 1, 2, and 3 years. Performance index was especially very high in the smaller-sized valves. After implantation with the subcoronary technique or root-inclusion technique, small cavities could be seen between the native aortic root and the Freestyle valve. Doppler values were evaluated for the Freestyle stentless porcine bioprostheses in the aortic root. Gradients appear to be close to those measured in native valves over a time period of 3 years.
Collapse
Affiliation(s)
- L H Baur
- Department of Cardiology, Leiden University Medical Center, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Senthilnathan V, Treasure T, Grunkemeier G, Starr A. Heart valves: which is the best choice? CARDIOVASCULAR SURGERY (LONDON, ENGLAND) 1999; 7:393-7. [PMID: 10430519 DOI: 10.1016/s0967-2109(99)00026-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- V Senthilnathan
- The Regional Cardiothoracic Unit, St George's Hospital, London, UK
| | | | | | | |
Collapse
|
12
|
Kon ND, Cordell AR, Adair SM, Dobbins JE, Kitzman DW. Aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis. Ann Thorac Surg 1999; 67:1609-15; discussion 1615-6. [PMID: 10391263 DOI: 10.1016/s0003-4975(99)00370-7] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND Stentless porcine prosthetic valves offer several advantages over traditional valves. Among these are superior hemodynamics, laminar flow patterns, lack of need for anticoagulation and perhaps improved durability. METHODS One hundred and twelve patients were operated on from September 17, 1992 to April 13, 1998 as part of a multi-center worldwide investigation. All patients received a total aortic root replacement. Patients were evaluated postoperatively at discharge, 3 to 6 months, and yearly by clinical exam and color flow Doppler echocardiography. RESULTS There were 4 deaths either in the hospital or within 30 days after surgery for an operative mortality of 3.6%. No patients experienced structural valve deterioration, non-structural valve deterioration, paravalvular leak, unacceptable hemodynamic performance, or postoperative endocarditis. The linearized rates for survival and thromboembolic complications at 5 years were 82.8% and 90.5% respectively. Excellent hemodynamic function is demonstrated by very low gradients, large EOA, and an exceedingly low incidence of any aortic regurgitation. CONCLUSIONS The Medtronic Freestyle aortic root bioprosthesis can be used safely to replace the aortic root for aortic valve and aortic root pathology. Root replacement allows optimal hemodynamic performance with no significant aortic regurgitation. Early and intermediate results are encouraging, but further follow-up is needed to determine valve durability.
Collapse
Affiliation(s)
- N D Kon
- Department of Cardiothoracic Surgery, Wake Forest University School of Medicine/Baptist Medical Center, Winston-Salem, North Carolina 27157-1096, USA.
| | | | | | | | | |
Collapse
|
13
|
Dumesnil JG, LeBlanc MH, Cartier PC, Métras J, Desaulniers D, Doyle DP, Lemieux MD, Raymond G. Hemodynamic features of the freestyle aortic bioprosthesis compared with stented bioprosthesis. Ann Thorac Surg 1998; 66:S130-3. [PMID: 9930433 DOI: 10.1016/s0003-4975(98)01119-9] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND The Freestyle prosthesis is a new stentless aortic bioprosthesis. Anticipated benefits are improved hemodynamics and increased longevity. METHODS Doppler echocardiograms were performed early and at 3 to 6 months, 1 year, and 2 years after operation in 157 patients (69 men, 88 women, aged 48 to 85 years) with this prosthesis, and results were compared with hemodynamic data in patients with Intact and Mosaic stented bioprostheses. RESULTS Distinctive features of the prosthesis compared with stented prostheses are (1) an increase in effective orifice area (+0.15+/-0.26 cm2; p < 0.05) and a decrease in mean gradient (-3.5+/-4.0 mm Hg; p < 0.001) during the first 3 to 6 months postoperatively and stabilization thereafter; (2) a markedly lower mean gradient at 1 year after operation (average, 6+/-4 mm Hg) than in stented prostheses (Intact, 22+/-8 mm Hg; Mosaic, 12+/-6 mm Hg); (3) in contrast to stented prostheses, in vivo effective orifice areas much lower (-0.91+/-0.35 cm2) than those calculated in vitro; (4) as in stented prostheses, the indexed effective orifice area (cm2/m2) is the best predictor (r = 0.77 at 1 year) of the mean gradient after operation; and (5) similar incidence of aortic regurgitation (trivial or mild, 34% versus 29% in Intact). CONCLUSIONS The hemodynamics of the Freestyle are very satisfactory and represent a marked improvement in comparison to stented prosthesis.
Collapse
Affiliation(s)
- J G Dumesnil
- Quebec Heart Institute, Laval Hospital, Ste-Foy, Canada
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Bach DS, David T, Yacoub M, Pepper J, Goldman B, Wood J, Verrier E, Petracek M, Aldrete V, Rosenbloom M, Azar H, Rakowski H. Hemodynamics and left ventricular mass regression following implantation of the Toronto SPV stentless porcine valve. Am J Cardiol 1998; 82:1214-9. [PMID: 9832097 DOI: 10.1016/s0002-9149(98)00607-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Stentless tissue valves may provide more favorable hemodynamics than conventional stented valves. Hemodynamic findings from a large multicenter trial have not been previously reported. The present report describes the hemodynamic findings from a multinational, multicenter study after implantation of the Toronto SPV valve. A total of 577 patients underwent aortic valve replacement with the Toronto SPV valve at 12 sites in 3 countries. Echocardiograms were recorded in the early postoperative period, 3 to 6 months after surgery, 1 year after surgery, and yearly thereafter, with follow-up to 3 years. Gradients decreased and effective orifice area increased in the months after surgery. One year after surgery, mean gradient for valve sizes 20 to 22, 23, 25, 27, and 29 mm was 7.3 +/- 4.4, 7.4 +/- 4.5, 6.1 +/- 3.3, 4.9 +/- 2.4, and 4.0 +/- 2.1 mm Hg, respectively; effective orifice area was 1.3 +/- 0.7, 1.5 +/- 0.5, 1.7 +/- 0.4, 2.0 +/- 0.4, and 2.4 +/- 0.6 cm2, respectively. There was a very low prevalence of significant aortic regurgitation at all time periods. There was significant left ventricular (LV) mass regression between the early and 3- to 6-month periods and between the 3- to 6-month and 1-year postoperative periods. The Toronto SPV valve has an excellent hemodynamic profile supported by significant regression of LV hypertrophy in the year after implantation. Data through 3 years demonstrates maintenance of low gradients and freedom from significant aortic regurgitation.
Collapse
Affiliation(s)
- D S Bach
- Department of Internal Medicine, University of Michigan, Ann Arbor 48109, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Sintek CF, Pfeffer TA, Kochamba GS, Yun KL, Fletcher AD, Khonsari S. Freestyle valve experience: technical considerations and mid-term results. J Card Surg 1998; 13:360-8. [PMID: 10440651 DOI: 10.1111/j.1540-8191.1998.tb01098.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Many studies have demonstrated the superior hemodynamics of stentless porcine aortic valves compared to stented valves. This article describes the operative techniques and reviews our 5-year experience with the Medtronic Freestyle stentless valve. METHODS Between January 1993 and November 1997, 95 patients underwent implantation of the Medtronic Freestyle valve at a mean age of 76 years. All patients were seen at 6 months, 1 year, and annually thereafter for clinical assessment and Doppler echocardiography. RESULTS There were three operative and ten late deaths (two cardiac and eight noncardiac). Three strokes and four transient ischemic attacks occurred in the follow-up period. Four patients had bacteremia that was treated successfully with antibiotics. No patient required reoperation for valve-related problems. Serial echocardiograms revealed a decrease in mean systolic gradients across the valve during the first year and an increase in effective orifice areas. Ninety-one percent of patients had no, or trace, aortic insufficiency at the time of discharge and this has not increased over time. CONCLUSION The Medtronic Freestyle valve has excellent hemodynamics and good clinical results. In our experience, no patient has required reoperation in a 5-year follow-up.
Collapse
Affiliation(s)
- C F Sintek
- Department of Cardiac Surgery, Kaiser Permanente Medical Center, Los Angeles, California, USA
| | | | | | | | | | | |
Collapse
|
16
|
Cutrara CA, Goldman BS, Christakis GT. Preferred method for insertion of the Toronto Stentless Porcine Valve. J Card Surg 1998; 13:408-11. [PMID: 10440657 DOI: 10.1111/j.1540-8191.1998.tb01104.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The Toronto Stentless Porcine Valve has been extensively used for aortic valve replacement. A standardized, detailed description of a preferred operative technique has been absent from the literature. A method is described that stresses (a) proper position and orientation of the aortotomy, (b) debridement of the diseased native valve, (C) proper sizing of the aortic root and choice of prosthesis and (d) implantation of the valve. Using this technique, the prosthesis can be reproducibly implanted with relative ease, without valvular insufficiency or coronary obstruction.
Collapse
Affiliation(s)
- C A Cutrara
- Division of Cardiovascular Surgery, Sunnybrook Health Science Centre, University of Toronto, Ontario, Canada
| | | | | |
Collapse
|
17
|
Del Rizzo DF, Abdoh A. Clinical and hemodynamic comparison of the Medtronic Freestyle and Toronto SPV stentless valves. J Card Surg 1998; 13:398-407. [PMID: 10440656 DOI: 10.1111/j.1540-8191.1998.tb01103.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The excellent hemodynamics of stentless valves have been observed by numerous investigators. With the recent release of the Toronto SPV (stentless porcine valve) and the Medtronic Freestyle stentless valves in North America, it is appropriate to now compare the clinical and hemodynamic performance of these devices. We analyzed the results of 995 patients who underwent aortic valve replacement (AVR) with either of the two valves; in all cases a subcoronary implant technique was used. There were important differences in the preoperative characteristics for the two groups: Medtronic Freestyle patients were notably older than the Toronto SPV patients (70.7+/-8.6 vs 61.8+/-11.1 years, p < 0.001) and were markedly more symptomatic (p < 0.0001). In the Toronto SPV group, most patients had New York Heart Association (NYHA) Class II (41.5%) or Class III (44.7%) symptoms preoperatively, while in the Freestyle group, 61.5% were in Class III and 12.5% were in Class IV. There were no notable differences in mortality or morbidity for the two groups. Both devices demonstrated a meaningful decrease in mean gradient and a corresponding increase in effective orifice area (EOA). Furthermore, the indexed EOA (EOA/body surface area [BSA]) was > 1cm2/m2 for all valves indicating there was no patient-prosthetic mismatch. There was a meaningful decrease in left ventricular (LV) mass as well as LV mass index (LVMI) for both devices up to 3 years postoperatively. Our data indicate that there were no differences in clinical outcome or hemodynamic performance of these two valves. Both devices offer excellent results with normalization of LV function.
Collapse
Affiliation(s)
- D F Del Rizzo
- Department of Surgery, University of Manitoba, Winnipeg, Canada.
| | | |
Collapse
|
18
|
Westaby S, Huysmans HA, David TE. Stentless aortic bioprostheses: compelling data from the Second International Symposium. Ann Thorac Surg 1998; 65:235-40. [PMID: 9456124 DOI: 10.1016/s0003-4975(97)01290-3] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND Stentless aortic xenografts are an important addition to the range of prosthetic valves. So far their use has been restricted to a limited number of study centers. This report summarizes the principal findings from the Second International Symposium on Stentless Bioprostheses. Attention is focused on the Toronto SPV and Freestyle valves recently approved by the United States Food and Drug Administration. METHODS Stentless xenografts are used predominantly in elderly patients with aortic stenosis. Implant techniques are more complex than for stented valves, as reflected by longer ischemic and cardiopulmonary bypass times. The valves have been subjected to detailed serial echocardiographic assessment and clinical follow-up. RESULTS The hemodynamic characteristics resemble those of the aortic homograft. There is a progressive increase in effective orifice area and decrease in transvalvular pressure gradients with time. Left ventricular mass index and wall thickness normalize between 6 and 12 months postoperatively. Left ventricular remodeling is accompanied by improved symptomatic status and a low incidence of valve-related complications. Limited comparative studies suggest important benefits over stented xenografts. Improved hemodynamics may translate into better bioprosthetic durability. CONCLUSIONS Reproducible and reliable implant methods should be taught carefully, but the hemodynamic advantages are substantial. Stentless xenografts are ideal for the elderly patient with aortic stenosis.
Collapse
Affiliation(s)
- S Westaby
- Oxford Heart Centre, John Radcliffe Hospital, United Kingdom
| | | | | |
Collapse
|
19
|
Bhatnagar G, Christakis GT, Murphy PM, Oxorn D, Goldman BS. Technique for reconstruction of the sinotubular junction. Ann Thorac Surg 1997; 63:559-60. [PMID: 9033347 DOI: 10.1016/s0003-4975(96)01036-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Correct geometric relationships between the annulus and sinotubular junction during stentless valve implantation are critical to minimize the development of insufficiency. Some patients with aortic valve disease have dilatation of the sinotubular junction and are unable to have a stentless valve placed by standard techniques. We recently encountered such a patient and reconstructed the sinotubular junction by aortic crenation. Multiple interrupted plicating sutures were used to reduce the aorta from a diameter of 42 mm to 28 mm. This method allows tailoring of the aorta to appropriate size by varying the number of crenating sutures.
Collapse
Affiliation(s)
- G Bhatnagar
- Division of Cardiovascular Surgery, Sunnybrook Health Science Centre, University of Toronto, Ontario, Canada
| | | | | | | | | |
Collapse
|
20
|
Del Rizzo DF, Goldman BS, Christakis GT, David TE. Hemodynamic benefits of the Toronto Stentless Valve. J Thorac Cardiovasc Surg 1996; 112:1431-45; discussion 1445-6. [PMID: 8975834 DOI: 10.1016/s0022-5223(96)70001-6] [Citation(s) in RCA: 82] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We report on 254 consecutive patients (170 male, 84 female) undergoing aortic valve replacement with the Toronto SPV Stentless Valve (St. Jude Medical, Inc., St. Paul, Minn.). Mean age (+/- standard deviation) was 62.1 +/- 11.6 years. Three patients (1%) received sizes 21 or 22 mm, 24 (9%) received size 23 mm, and 227 patients (89%) received sizes 25, 27, or 29 mm. Serial echocardiography was used to assess valve performance during a 3-year follow-up. Mean gradient decreased by 35.8% (p < 0.0001; 95% confidence interval -39.6%, -31.7%) from postoperative values to the 3- to 6-month follow-up and by 6.1% (p = 0.004; 95% confidence interval -10.1%, -2%) at each subsequent interval; effective orifice area increased by 17.2% (p = 0.0001; 95% confidence interval 12.0%, 22.6%) initially and by 4.4% (p < 0.001; 95% confidence interval 1.8%, 7.0%) thereafter. At 2 years of follow-up, mean gradient was 3.3 +/- 2.1 mm Hg and mean effective orifice area was 2.2 +/- 0.8 cm2. Studies on left ventricular mass were carried out on 84 patients. Left ventricular mass decreased by 14.3% (37.8 +/- 57.9 gm; p < 0.0001; 95% confidence interval -53.7, -21.9 gm) and left ventricular mass index decreased by 15.2% (21.1 +/- 30.5 gm/m2; p < 0.0001; 95% confidence interval -29.5, -12.7 gm/m2) from postoperative values to the 3- to 6-month follow-up interval. The reduction in residual gradient and potential regression in left ventricular hypertrophy may have a beneficial prognostic implication. We believe that the unique stentless design of the Toronto SPV Stentless Valve allows this to occur.
Collapse
Affiliation(s)
- D F Del Rizzo
- Sunnybrook Health Science Centre, University of Toronto, Canada
| | | | | | | |
Collapse
|
21
|
Christakis GT, Joyner CD, Morgan CD, Fremes SE, Buth KJ, Sever JY, Rao V, Panagiotopoulos KP, Murphy PM, Goldman BS. Left ventricular mass regression early after aortic valve replacement. Ann Thorac Surg 1996; 62:1084-9. [PMID: 8823093 DOI: 10.1016/0003-4975(96)00533-4] [Citation(s) in RCA: 77] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
BACKGROUND Regression of left ventricular hypertrophy is an important and well-recognized salutary effect of aortic valve replacement. The earliest evidence of left ventricular mass regression after aortic valve replacement and the influence of prosthesis type are not well known, and were the focus of this study. METHODS Transthoracic echocardiography was used to measure left ventricular mass index preoperatively and before discharge in 57 consecutive patients undergoing isolated aortic valve replacement (with or without coronary artery bypass grafting). RESULTS Three patients were excluded from the study because of inability to obtain accurate M-mode echocardiographic images for left ventricular mass measurement preoperatively (1) or postoperatively (2). Of the remaining 54 patients, mechanical bileaflet valves were used in 19, stented tissue bioprostheses were implanted in 15, and a stentless porcine bioprosthesis was chosen for 20. Postoperative echocardiograms were obtained 4.9 +/- 2.3 days after aortic valve replacement (range, 2 to 9 days). A two-way repeated-measures analysis of variance demonstrated a significant reduction of left ventricular mass index before discharge (preoperative 141.4 +/- 45.2 g/m2, postoperative 127.5 +/- 32.8 g/m2; p = 0.0005) but no differences between prostheses. CONCLUSIONS Left ventricular mass regression begins early after aortic valve replacement, probably because of reduction of transvalvular gradients and left ventricular wall stress. At least in the very early postoperative period, the type of prosthesis does not influence the extent of mass regression.
Collapse
Affiliation(s)
- G T Christakis
- Division of Cardiovascular Surgery, Sunnybrook Health Science Centre, University of Toronto, Ontario, Canada
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Meloni L, Ricchi A, Cirio E, Falchi S, Abbruzzese PA, Aru GM, Martelli V, Ross D, Cherchi A. Echocardiographic assessment of aortic valve replacement with stentless porcine xenografts. Am J Cardiol 1995; 76:294-6. [PMID: 7618627 DOI: 10.1016/s0002-9149(99)80084-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Stentless porcine xenografts (SPXs) implanted in the aortic position have potential hemodynamic advantages over traditional valve prostheses because of the lack of a rigid stent. Twenty-four patients (mean age 59 years) who underwent aortic valve replacement with SPXs were studied by echocardiography early after and 26 +/- 10 months (range 8 to 40) after operation. Peak and mean gradients, as well as aortic valve area, did not change significantly from baseline (16.3 +/- 8 and 9.8 +/- 5.6 mm Hg, and 1.78 +/- 0.63 cm2, respectively) to follow-up study (12.5 +/- 5 and 7.7 +/- 3 mm Hg, and 1.8 +/- 0.65 cm2, respectively). At baseline, color flow Doppler imaging showed aortic valve regurgitation where the leaflets coapted centrally in 17 of 24 patients (trivial, n = 14; mild, n = 3). Besides the central leak, paravalvular regurgitation was seen in 4 patients (trivial, n = 3; mild, n = 1). At follow-up, 18 of 24 patients had aortic valve regurgitation (trivial, n = 11; mild, n = 6; and moderate, n = 1). New valvular regurgitation (graded as trivial, n = 2; mild, n = 2; and moderate, n = 1) was detected in 5 patients, and new paravalvular regurgitation (graded as mild) developed in 1 patient. Two patients underwent repeat operation for valve-related complications: (1) rupture of a valve cusp with acute pulmonary edema, and (2) fibrotic stenosis of the left coronary ostium with unstable angina. In conclusion, this study demonstrates good hemodynamic performance of the SPX in the aortic position.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- L Meloni
- Istituto di Cardiologia, Universitá degli Studi di Cagliari, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Mohr FW, Walther T, Baryalei M, Falk V, Autschbach R, Scheidt A, Dalichau H. The Toronto SPV bioprosthesis: One-year results in 100 patients. Ann Thorac Surg 1995. [DOI: 10.1016/s0003-4975(95)00388-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
24
|
Kon ND, Westaby S, Amarasena N, Pillai R, Cordell AR. Comparison of implantation techniques using freestyle stentless porcine aortic valve. Ann Thorac Surg 1995; 59:857-62. [PMID: 7695409 DOI: 10.1016/0003-4975(95)00066-t] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Stentless porcine aortic valves demonstrate superior hemodynamic performance when compared with their stented counterparts. The technical considerations for implanting these valves can be demanding. The Medtronic Freestyle aortic root bioprosthesis resembles an allograft, has zero-pressure-fixed leaflets treated with an antimineralization agent, and can be implanted using a variety of techniques. In this study of that valve, total root replacement (TRR) was compared with a partial scallop aortic inclusion technique (PSI). Implications were performed in 75 patients (49 PSI and 26 TRR). There were no significant differences with respect to age, sex, or incidence of concomitant procedures. Mean aortic cross-clamp times were significantly less in the PSI group than in the TRR group (51.8 +/- 11.7 minutes versus 125.5 +/- 19.7 minutes; p = 0.0001). At discharge, mean systolic gradients seen on color-flow Doppler echocardiography were less in the TRR group than in the PSI group (6.17 +/- 3.66 versus 10.01 +/- 4.83 mm Hg; p = 0.014). Discharge echocardiography revealed trivial valve regurgitation in 8.3% of the TRR group and in 41.7% of the PSI group (p = 0.004). No patient experienced any significant valvular regurgitation on discharge echocardiography. We conclude that early experience with the Medtronic Freestyle aortic root bioprosthesis shows excellent short-term function regardless of implantation technique. Shorter cross-clamp times, comparable with those of stented valve procedures, occurred with PSI implantation. We anticipate that effects on long-term durability will be beneficial.
Collapse
Affiliation(s)
- N D Kon
- Department of Cardiothoracic Surgery, Bowman Gray School of Medicine, Winston-Salem, North Carolina 27103
| | | | | | | | | |
Collapse
|