Thermann F, Ukkat J, Wollert U, Dralle H, Brauckhoff M. Dialysis shunt-associated steal syndrome (DASS) following brachial accesses: the value of fistula banding under blood flow control.
Langenbecks Arch Surg 2007;
392:731-7. [PMID:
17602241 DOI:
10.1007/s00423-007-0207-0]
[Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2006] [Accepted: 06/05/2007] [Indexed: 11/29/2022]
Abstract
BACKGROUND
Dialysis shunt-associated steal syndrome (DASS) is a rare complication of hemodialysis access (HA) which preferably occurs in brachial fistulas. Treatment options are discussed controversially. Aim of this study was to evaluate flow-controlled fistula banding.
MATERIALS AND METHODS
Patients treated between 2002 and 2006 were included in this prospective survey. According to a classification we established, patients were typed DASS I-III (I: short history, no dermal lesions; II: long history, skin lesions; III: long history, gangrene). Surgical therapy was HA banding including controlled reduction (about 50% of initial flow) of HA blood flow (patients type I and II). Patients with type III underwent closure of the HA.
RESULTS
In 15 patients with relevant DASS, blood-flow-controlled banding was performed. In ten patients (all type I), banding led to restitution of the hand function while preserving the HA. In five patients (all type II), banding was not successful; in two patients, closure of the HA was performed eventually. In five patients (type III), primary closure of the HA was performed. Four patients with DASS type II but only two with DASS type I had diabetes mellitus (p = 0.006).
CONCLUSIONS
Banding under blood flow control resulting in an approximately 50% reduction in the initial blood flow is an adequate therapeutic option in patients with brachial HA and type I-DASS. In type II-DASS, banding does not lead to satisfying results, more complex surgical options might be more successful. Diabetes is associated with poor HA outcome in case of DASS.
Collapse