1
|
Orozco J, Pan G, Sattayasamitsathit S, Galarnyk M, Wang J. Micromotors to capture and destroy anthrax simulant spores. Analyst 2015; 140:1421-7. [PMID: 25622851 DOI: 10.1039/c4an02169j] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Towards addressing the need for detecting and eliminating biothreats, we describe a micromotor-based approach for screening, capturing, isolating and destroying anthrax simulant spores in a simple and rapid manner with minimal sample processing. The B. globilli antibody-functionalized micromotors can recognize, capture and transport B. globigii spores in environmental matrices, while showing non-interactions with excess of non-target bacteria. Efficient destruction of the anthrax simulant spores is demonstrated via the micromotor-induced mixing of a mild oxidizing solution. The new micromotor-based approach paves a way to dynamic multifunctional systems that rapidly recognize, isolate, capture and destroy biological threats.
Collapse
Affiliation(s)
- Jahir Orozco
- Department of Nanoengineering, University of California, San Diego, La Jolla, California 92093, USA.
| | | | | | | | | |
Collapse
|
2
|
Bacillus thuringiensis as a surrogate for Bacillus anthracis in aerosol research. World J Microbiol Biotechnol 2013; 30:1453-61. [PMID: 24338558 DOI: 10.1007/s11274-013-1576-x] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2013] [Accepted: 12/03/2013] [Indexed: 10/25/2022]
Abstract
Characterization of candidate surrogate spores prior to experimental use is critical to confirm that the surrogate characteristics are as closely similar as possible to those of the pathogenic agent of interest. This review compares the physical properties inherent to spores of Bacillus anthracis (Ba) and Bacillus thuringiensis (Bt) that impact their movement in air and interaction with surfaces, including size, shape, density, surface morphology, structure and hydrophobicity. Also evaluated is the impact of irradiation on the physical properties of both Bacillus species. Many physical features of Bt and Ba have been found to be similar and, while Bt is considered typically non-pathogenic, it is in the B. cereus group, as is Ba. When cultured and sporulated under similar conditions, both microorganisms share a similar cylindrical pellet shape, an aerodynamic diameter of approximately 1 μm (in the respirable size range), have an exosporium with a hairy nap, and have higher relative hydrophobicities than other Bacillus species. While spore size, morphology, and other physical properties can vary among strains of the same species, the variations can be due to growth/sporulation conditions and may, therefore, be controlled. Growth and sporulation conditions are likely among the most important factors that influence the representativeness of one species, or preparation, to another. All Bt spores may, therefore, not be representative of all Ba spores. Irradiated spores do not appear to be a good surrogate to predict the behavior of non-irradiated spores due to structural damage caused by the irradiation. While the use of Bt as a surrogate for Ba in aerosol testing appears to be well supported, this review does not attempt to narrow selection between Bt strains. Comparative studies should be performed to test the hypothesis that viable Ba and Bt spores will behave similarly when suspended in the air (as an aerosol) and to compare the known microscale characteristics versus the macroscale response.
Collapse
|
3
|
Gamma irradiation can be used to inactivate Bacillus anthracis spores without compromising the sensitivity of diagnostic assays. Appl Environ Microbiol 2008; 74:4427-33. [PMID: 18515484 DOI: 10.1128/aem.00557-08] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The use of Bacillus anthracis as a biological weapon in 2001 heightened awareness of the need for validated methods for the inactivation of B. anthracis spores. This study determined the gamma irradiation dose for inactivating virulent B. anthracis spores in suspension and its effects on real-time PCR and antigen detection assays. Strains representing eight genetic groups of B. anthracis were exposed to gamma radiation, and it was found that subjecting spores at a concentration of 10(7) CFU/ml to a dose of 2.5 x 10(6) rads resulted in a 6-log-unit reduction of spore viability. TaqMan real-time PCR analysis of untreated versus irradiated Ames strain (K1694) spores showed that treatment significantly enhanced the detection of B. anthracis chromosomal DNA targets but had no significant effect on the ability to detect targets on the pXO1 and pXO2 plasmids of B. anthracis. When analyzed by an enzyme-linked immunosorbent assay (ELISA), irradiation affected the detection of B. anthracis spores in a direct ELISA but had no effect on the limit of detection in a sandwich ELISA. The results of this study showed that gamma irradiation-inactivated spores can be tested by real-time PCR or sandwich ELISA without decreasing the sensitivity of either type of assay. Furthermore, the results suggest that clinical and public health laboratories which test specimens for B. anthracis could potentially incorporate gamma irradiation into sample processing protocols without compromising the sensitivity of the B. anthracis assays.
Collapse
|
4
|
Mechaly A, Zahavy E, Fisher M. Development and implementation of a single-chain Fv antibody for specific detection of Bacillus anthracis spores. Appl Environ Microbiol 2008; 74:818-22. [PMID: 17965209 PMCID: PMC2227706 DOI: 10.1128/aem.01244-07] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2007] [Accepted: 10/07/2007] [Indexed: 11/20/2022] Open
Abstract
A single-chain Fv (scFv) antibody was developed and applied for efficient and specific detection of Bacillus anthracis spores. The antibody was isolated from a phage display library prepared from spleens of mice immunized with a water-soluble extract of the outer membrane of the B. anthracis spore (exosporium). The library (7 x 10(6) PFU) was biopanned against live, native B. anthracis ATCC delta14185 spores suspended in solution, resulting in the isolation of a unique soluble scFv antibody. The antibody was affinity purified and its affinity constant (3 x 10(8) +/- 1 x 10(8) M(-1)) determined via flow cytometry (FCM). Preliminary characterization of scFv specificity indicated that the scFv antibody does not cross-react with representatives of some phylogenetically related Bacillus spores. The potential use of scFv antibodies in detection platforms was demonstrated by the successful application of the soluble purified scFv antibody in enzyme-linked immunosorbent assays, immunofluorescence assays, and FCM.
Collapse
Affiliation(s)
- A Mechaly
- Department of Infectious Diseases, Israel Institute for Biological Research, P.O. Box 19, Ness-Ziona 74100, Israel
| | | | | |
Collapse
|
5
|
Zahavy E, Fisher M, Bromberg A, Olshevsky U. Detection of frequency resonance energy transfer pair on double-labeled microsphere and Bacillus anthracis spores by flow cytometry. Appl Environ Microbiol 2003; 69:2330-9. [PMID: 12676717 PMCID: PMC154795 DOI: 10.1128/aem.69.4.2330-2339.2003] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Development of an ultrasensitive biosensor for biological hazards in the environment is a major need for pollutant control and for the detection of biological warfare. Fluorescence methods combined with immunodiagnostic methods are the most common. To minimize background noise, arising from the unspecific adsorption effect, we have adapted the FRET (frequency resonance energy transfer) effect to the immunofluorescence method. FRET will increase the selectivity of the diagnosis process by introducing a requirement for two different reporter molecules that have to label the antigen surface at a distance that will enable FRET. Utilizing the multiparameter capability of flow cytometry analysis to analyze the double-labeling/FRET immunostaining will lead to a highly selective and sensitive diagnostic method. This work examined the FRET interaction of fluorescence-labeled avidin molecules on biotin-coated microspheres as a model system. As target system, we have used labeled polyclonal antibodies on Bacillus anthracis spores. The antibodies used were purified immunoglobulin G (IgG) molecules raised in rabbits against B. anthracis exosoporium components. The antibodies were fluorescence labeled by a donor-acceptor chromophore pair, alexa488 as a donor and alexa594 as an acceptor. On labeling the spores with alexa488-IgG as a donor and alexa594-IgG as an acceptor, excitation at 488 nm results in quenching of the alexa-488 fluorescence (E(q) = 35%) and appearance of the alexa594 fluorescence (E(s) = 22%), as detected by flow cytometry analysis. The FRET effect leads to a further isolated gate (FL1/FL3) for the target spores compared to competitive spores such as B. thuringiensis subsp. israelensis and B. subtilis. This new approach, combining FRET labeling and flow cytometry analysis, improved the selectivity of the B. anthracis spores by a factor of 10 with respect to B. thuringiensis subsp. israelensis and a factor of 100 with respect to B. subtilis as control spores.
Collapse
Affiliation(s)
- E Zahavy
- Department of Physical Chemistry, Israel Institute for Biological Research, Ness-Ziona 74100, Israel.
| | | | | | | |
Collapse
|
6
|
Zhou B, Wirsching P, Janda KD. Human antibodies against spores of the genus Bacillus: a model study for detection of and protection against anthrax and the bioterrorist threat. Proc Natl Acad Sci U S A 2002; 99:5241-6. [PMID: 11959974 PMCID: PMC122754 DOI: 10.1073/pnas.082121599] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
A naive, human single-chain Fv (scFv) phage-display library was used in bio-panning against live, native spores of Bacillus subtilis IFO 3336 suspended in solution. A direct in vitro panning and enzyme-linked immunosorbent assay-based selection afforded a panel of nine scFv-phage clones of which two, 5B and 7E, were chosen for further study. These two clones differed in their relative specificity and affinity for spores of B. subtilis IFO 3336 vs. a panel of spores from 11 other Bacillus species/strains. A variety of enzyme-linked immunosorbent assay protocols indicated these scFv-phage clones recognized different spore epitopes. Notably, some spore epitopes markedly changed between the free and microtiter-plate immobilized state as revealed by antibody-phage binding. An additional library selection procedure also was examined by constructing a Fab chain-shuffled sublibrary from the nine positive clones and by using a subtractive panning strategy to remove crossreactivity with B. licheniformis 5A24. The Fab-phage clone 52 was improved compared with 5B and was comparable to 7E in binding B. subtilis IFO 3336 vs. B. licheniformis 5A24, yet showed a distinctive crossreactivity pattern with other spores. We also developed a method to directly detect individual spores by using fluorescently labeled antibody-phage. Finally, a variety of "powders" that might be used in deploying spores of B. anthracis were examined for antibody-phage binding. The strategies described provide a foundation to discover human antibodies specific for native spores of B. anthracis that can be developed as diagnostic and therapeutic reagents.
Collapse
Affiliation(s)
- Bin Zhou
- Department of Chemistry, The Scripps Research Institute and The Skaggs Institute for Chemical Biology, 10550 North Torrey Pines Road, La Jolla, CA 92037, USA
| | | | | |
Collapse
|
7
|
Iqbal SS, Mayo MW, Bruno JG, Bronk BV, Batt CA, Chambers JP. A review of molecular recognition technologies for detection of biological threat agents. Biosens Bioelectron 2001; 15:549-78. [PMID: 11213217 DOI: 10.1016/s0956-5663(00)00108-1] [Citation(s) in RCA: 272] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The present review summarizes the state of the art in molecular recognition of biowarfare agents and other pathogens and emphasizes the advantages of using particular types of reagents for a given target (e.g. detection of bacteria using antibodies versus nucleic acid probes). It is difficult to draw firm conclusions as to type of biorecognition molecule to use for a given analyte. However, the detection method and reagents are generally target-driven and the user must decide on what level (genetic versus phenotypic) the detection should be performed. In general, nucleic acid-based detection is more specific and sensitive than immunological-based detection, while the latter is faster and more robust. This review also points out the challenges faced by military and civilian defense components in the rapid and accurate detection and identification of harmful agents in the field. Although new and improved sensors will continue to be developed, the more crucial need in any biosensor may be the molecular recognition component (e.g. antibody, aptamer, enzyme, nucleic acid, receptor, etc.). Improvements in the affinity, specificity and mass production of the molecular recognition components may ultimately dictate the success or failure of detection technologies in both a technical and commercial sense. Achieving the ultimate goal of giving the individual soldier on the battlefield or civilian responders to an urban biological attack or epidemic, a miniature, sensitive and accurate biosensor may depend as much on molecular biology and molecular engineering as on hardware engineering. Fortunately, as this review illustrates, a great deal of scientific attention has and is currently being given to the area of molecular recognition components. Highly sensitive and specific detection of pathogenic bacteria and viruses has increased with the proliferation of nucleic acid and immuno-based detection technologies. If recent scientific progress is a fair indicator, the future promises remarkable new developments in molecular recognition elements for use in biosensors with a vast array of applications.
Collapse
Affiliation(s)
- S S Iqbal
- Systems & Processes Engineering Corporation, Austin, TX 78701, USA
| | | | | | | | | | | |
Collapse
|
8
|
Quinlan JJ, Foegeding PM. Monoclonal antibodies for use in detection of Bacillus and Clostridium spores. Appl Environ Microbiol 1997; 63:482-7. [PMID: 9023926 PMCID: PMC168338 DOI: 10.1128/aem.63.2.482-487.1997] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Five monoclonal antibodies against bacterial spores of Bacillus cereus T and Clostridium sporogenes PA3679 were developed. Two antibodies (B48 and B183) were selected for their reactivity with B. cereus T spores, two (C33 and C225) were selected for their reactivity with C. sporogenes spores, and one (D89) was selected for its reactivity with both B. cereus and C sporogenes spores. The isotypes of the antibodies were determined to be immunoglobulin G2a (IgG2a) (B48), IgG1 (B183), and IgM (C33, C225, and D89). The antibodies reacted with spores of B. cereus T, Bacillus subtilis subsp. globigii, Bacillus megaterium, Bacillus stearothermophilus, C. sporogenes, Clostridium perfringens, and Desulfotomaculum nigrificans. Antibody D89 also reacted with vegetative cells of B. cereus and C. sporogenes. Analysis of B. cereus spore extracts showed that two of the antigens with which the anti-Bacillus antibodies reacted had molecular masses of 76 kDa and approximately 250 kDa. Immunocytochemical localization indicated that antigens with which B48, B183, and D89 react are on the exosporium of the B. cereus T spore. Antibody D89 reacted with the exosporium and outer cortex of C. sporogenes spores in immunocytochemical localization studies but did not react with extracts of C. sporogenes or B. cereus spores in Western blotting. Some C. sporogenes antigens were not stable during long-term storage at -20 degrees C. Antibodies B48, B183, and D89 should prove to be useful tools for developing immunological methods for the detection of bacterial spores.
Collapse
Affiliation(s)
- J J Quinlan
- Department of Food Science, North Carolina State University, Raleigh, USA
| | | |
Collapse
|
9
|
Turnbull PC, Hutson RA, Ward MJ, Jones MN, Quinn CP, Finnie NJ, Duggleby CJ, Kramer JM, Melling J. Bacillus anthracis but not always anthrax. THE JOURNAL OF APPLIED BACTERIOLOGY 1992; 72:21-8. [PMID: 1541596 DOI: 10.1111/j.1365-2672.1992.tb04876.x] [Citation(s) in RCA: 61] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Gram-positive bacilli isolated during epidemiological investigations which, on the basis of conventional tests, resemble Bacillus anthracis but which fail to produce the capsule or to induce anthrax in test animals have long been dismissed in clinical and veterinary laboratories as B. cereus or simply as unidentified Bacillus spp. and thereupon discarded as inconsequential. In this study, the application of newly available DNA probe, polymerase chain reaction and specific toxin antigen detection technology has revealed that a proportion of such strains are B. anthracis which lack the plasmid carrying the capsule gene (pXO2). While these techniques cannot, of course, be used to confirm the identities of strains resembling B. anthracis but which also lack the plasmid carrying the toxin genes (pXO1), the likelihood that these also are bona fide B. anthracis becomes more acceptable. (As yet no naturally occurring pXO1-/2+ strains have been found.) At this point, the significance of the presence of such avirulent forms of B. anthracis in specimens can only be a subject for speculation, but the possibility that they may be indicators of virulent parents somewhere in the system being examined must be considered.
Collapse
Affiliation(s)
- P C Turnbull
- Division of Biologics, Public Health Laboratory Service Centre for Applied Microbiology & Research, Porton Down, Salisbury, Wiltshire, UK
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Turnbull P, Hutson R, Ward MJ, Jones MN, Quinn C, Finnie N, Duggleby C, Kramer J, Melling J. Bacillus anthracis but not always anthrax. J Appl Microbiol 1992. [DOI: 10.1111/j.1365-2672.1992.tb05181.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Phillips AP, Ezzell JW. Identification of Bacillus anthracis by polyclonal antibodies against extracted vegetative cell antigens. THE JOURNAL OF APPLIED BACTERIOLOGY 1989; 66:419-32. [PMID: 2502530 DOI: 10.1111/j.1365-2672.1989.tb05111.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The extractable protein antigens EA1 and EA2 of Bacillus anthracis were prepared from electrophoresis transblots of SDS extracts of vegetative bacteria of the Sterne strain. Hyperimmune guinea-pig antiserum against EA2 failed to react with B. anthracis cells in immunofluorescence (IF) tests. Guinea-pig antiserum against EA1 (anti-EA1) reacted strongly in IF tests with non-encapsulated vegetative cell of 10 of 12 strains of B. anthracis and with cells of strains of B. cereus and B. thuringiensis. The unreactive B. anthracis strains were delta-Vollum-1B-1 and Texas. Encapsulated cells of B. anthracis stained poorly except for small bright regions. Absorption of anti-EA1 with cells of B. cereus NCTC 8035 and NCTC 9946 removed activity towards all B. cereus strains tested, but only partly reduced cross-reaction with B. thuringiensis strains. Absorption of anti-EA1 with B. thuringiensis 4041 removed activity towards this strain and B. cereus strains. Evidence is produced that B. thuringiensis cells grown on nutrient agar possess more cross-reacting antigens than cells grown in nutrient broth. The reaction of anti-EA1 with Bacillus spores immobilized in clumps on microscope slides was attributed to contaminating vegetative debris because well-separated individual spores failed to react. A rapid IF test was developed allowing identification of B. anthracis sampled from overnight cultures on blood plates. When sodium dodecyl sulphate extracts of B. anthracis vegetative cells were analysed on immunoblots (Western blots) by reaction with anti-EA1, a number of bands were visualized in addition to the expected 91 kiloDalton EA1 band. Prior absorption of anti-EA1 with B. cereus or B. thuringiensis cells resulted in the disappearance of most or all of the brands in blots of these species, but had less effect on blots of the B. anthracis strains. All six B. anthracis strains that were blotted including delta-Vollum-1B-1 and Texas, could thus be distinguished from B. cereus and B. thuringiensis by their differential reaction with unabsorbed and absorbed anti-EA1.
Collapse
Affiliation(s)
- A P Phillips
- Chemical Defence Establishment, Salisbury, Wiltshire, UK
| | | |
Collapse
|