1
|
Morin M, Björklund S, Jankovskaja S, Moore K, Delgado-Charro MB, Ruzgas T, Guy RH, Engblom J. Reverse Iontophoretic Extraction of Skin Cancer-Related Biomarkers. Pharmaceutics 2021; 14:79. [PMID: 35056976 PMCID: PMC8778044 DOI: 10.3390/pharmaceutics14010079] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 12/16/2021] [Accepted: 12/22/2021] [Indexed: 11/16/2022] Open
Abstract
Non-invasive methods for early diagnosis of skin cancer are highly valued. One possible approach is to monitor relevant biomarkers such as tryptophan (Trp) and kynurenine (Kyn), on the skin surface. The primary aim of this in vitro investigation was, therefore, to examine whether reverse iontophoresis (RI) can enhance the extraction of Trp and Kyn, and to demonstrate how the Trp/Kyn ratio acquired from the skin surface reflects that in the epidermal tissue. The study also explored whether the pH of the receiver medium impacted on extraction efficiency, and assessed the suitability of a bicontinuous cubic liquid crystal as an alternative to a simple buffer solution for this purpose. RI substantially enhanced the extraction of Trp and Kyn, in particular towards the cathode. The Trp/Kyn ratio obtained on the surface matched that in the viable skin. Increasing the receiver solution pH from 4 to 9 improved extraction of both analytes, but did not significantly change the Trp/Kyn ratio. RI extraction of Trp and Kyn into the cubic liquid crystal was comparable to that achieved with simple aqueous receiver solutions. We conclude that RI offers a potential for non-invasive sampling of low-molecular weight biomarkers and further investigations in vivo are therefore warranted.
Collapse
Affiliation(s)
- Maxim Morin
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, SE-205 06 Malmö, Sweden; (S.B.); (S.J.); (T.R.)
- Biofilms—Research Center for Biointerfaces, Malmö University, SE-205 06 Malmö, Sweden
| | - Sebastian Björklund
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, SE-205 06 Malmö, Sweden; (S.B.); (S.J.); (T.R.)
- Biofilms—Research Center for Biointerfaces, Malmö University, SE-205 06 Malmö, Sweden
| | - Skaidre Jankovskaja
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, SE-205 06 Malmö, Sweden; (S.B.); (S.J.); (T.R.)
- Biofilms—Research Center for Biointerfaces, Malmö University, SE-205 06 Malmö, Sweden
| | - Kieran Moore
- Department of Pharmacy & Pharmacology, University of Bath, Claverton Down, Bath BA2 7AY, UK; (K.M.); (M.B.D.-C.); (R.H.G.)
| | - Maria Begoña Delgado-Charro
- Department of Pharmacy & Pharmacology, University of Bath, Claverton Down, Bath BA2 7AY, UK; (K.M.); (M.B.D.-C.); (R.H.G.)
| | - Tautgirdas Ruzgas
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, SE-205 06 Malmö, Sweden; (S.B.); (S.J.); (T.R.)
- Biofilms—Research Center for Biointerfaces, Malmö University, SE-205 06 Malmö, Sweden
| | - Richard H. Guy
- Department of Pharmacy & Pharmacology, University of Bath, Claverton Down, Bath BA2 7AY, UK; (K.M.); (M.B.D.-C.); (R.H.G.)
| | - Johan Engblom
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, SE-205 06 Malmö, Sweden; (S.B.); (S.J.); (T.R.)
- Biofilms—Research Center for Biointerfaces, Malmö University, SE-205 06 Malmö, Sweden
| |
Collapse
|
2
|
English R, Ruiz S. Conflicting Reports Regarding the Histopathological Features of Androgenic Alopecia: Are Biopsy Location, Hair Diameter Diversity, and Relative Hair Follicle Miniaturization Partly to Blame? Clin Cosmet Investig Dermatol 2021; 14:357-365. [PMID: 33854354 PMCID: PMC8039045 DOI: 10.2147/ccid.s306157] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 03/24/2021] [Indexed: 11/23/2022]
Abstract
Despite decades of study, debate persists over the role of inflammation, fibrosis, and prostaglandins in the histopathology of androgenic alopecia (AGA). This brief review proposes that inconsistent findings across histological studies are a consequence of three inadequately controlled variables: 1) biopsy location, 2) hair diameter diversity (HDD), and 3) relative hair follicle miniaturization (HFM) within and across subjects. We suggest new methodological considerations to improve AGA histopathological research, as well as a novel classification system to quantify HFM by its stages. Finally, we hypothesize a dynamic relationship between inflammation, fibrosis, and prostaglandin activity dependent on relative HFM.
Collapse
Affiliation(s)
| | - Sophia Ruiz
- Perfect Hair Health, San Francisco, CA, 94115, USA
| |
Collapse
|
3
|
Giri TK, Chakrabarty S, Ghosh B. Non-Invasive Extraction of Gabapentin for Therapeutic Drug Monitoring by Reverse Iontophoresis: Effect of pH, Ionic Strength, and Polyethylene Glycol 400 in the Receiving Medium. CURR PHARM ANAL 2019. [DOI: 10.2174/1573412914666180910115059] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Monitoring of plasma concentrations is a necessity for narrow therapeutic index
potent drugs. Development of non-invasive methods can save the patients from the trauma of needles
and hence is considered as a research priority.
Introduction:
Gabapentin, an anti-epileptic drug requires therapeutic monitoring because of its narrow
therapeutic index. The objective of the study was to develop a suitable method for the non-invasive
extraction of gabapentin for the same.
Methods:
Transdermal reverse iontophoresis was performed using pig ear skin as a barrier membrane.
Three compartment iontophoretic cells were used for the extraction study. Extractions were carried out
under low intensity electric field (current intensity- 0.5 mA/cm2, electrical field approximately 5 V).
The donor compartment was charged with aqueous gabapentin (10 µg/ml in phosphate buffer of pH
7.4). For studying the effect of receiving vehicle (pH, ionic strength, and enhancer) on the extraction
efficiency of gabapentin, the two receiver chambers were charged with media having varying concentration
of these factors. Drug content was determined by HPLC.
Results:
Compared to other pHs, cumulative extraction of gabapentin at pH 5 was significantly higher
at both anode and cathode (p<0.001). At low ionic strength, extraction of gabapentin increased linearly
with the increase in concentration of ions up to a certain value but at very high ionic strength the pattern
reversed. Similar results were obtained with enhancer (polyethylene glycol 400). Extraction increased
with increase in polyethylene glycol 400 up to 3% and then decreased.
Conclusion:
Extraction flux can be optimized by manipulation of the receiver media.
Collapse
Affiliation(s)
- Tapan Kumar Giri
- NSHM College of Pharmaceutical Technology, NSHM Knowledge Campus, Kolkata Group of Institutions, 124 BL Saha Road, Kolkata-700053, West Bengal, India
| | - Subhasis Chakrabarty
- NSHM College of Pharmaceutical Technology, NSHM Knowledge Campus, Kolkata Group of Institutions, 124 BL Saha Road, Kolkata-700053, West Bengal, India
| | - Bijaya Ghosh
- NSHM College of Pharmaceutical Technology, NSHM Knowledge Campus, Kolkata Group of Institutions, 124 BL Saha Road, Kolkata-700053, West Bengal, India
| |
Collapse
|
4
|
Giri TK, Chakrabarty S, Ghosh B. Transdermal reverse iontophoresis: A novel technique for therapeutic drug monitoring. J Control Release 2016; 246:30-38. [PMID: 27956143 DOI: 10.1016/j.jconrel.2016.12.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Accepted: 12/07/2016] [Indexed: 11/27/2022]
Abstract
Application of transdermal reverse iontophoresis for diagnostic purpose is a relatively new concept but its short span of research is full of ups and downs. In early nineties, when the idea was floated, it received a dubious welcome by the scientific community. Yet to the disbelief of many, 2001 saw the launching of GlucoWatch® G2 Biographer, the first device that could measure the blood sugar level noninvasively. Unfortunately, the device failed to match the expectation and was withdrawn in 2007. However, the concept stayed on. Research on reverse iontophoresis has diversified in many fields. Numerous in vitro and in vivo experiments confirmed the prospect of reverse iontophoresis as a noninvasive tool in therapeutic drug monitoring and clinical chemistry. This review provides an overview about the recent developments in reverse iontophoresis in the field of therapeutic drug monitoring.
Collapse
Affiliation(s)
- Tapan Kumar Giri
- NSHM College of Pharmaceutical Technology, NSHM Knowledge Campus, Kolkata Group of Institutions, 124 BL Saha Road, Kolkata-700053, West Bengal, India
| | - Subhasis Chakrabarty
- NSHM College of Pharmaceutical Technology, NSHM Knowledge Campus, Kolkata Group of Institutions, 124 BL Saha Road, Kolkata-700053, West Bengal, India
| | - Bijaya Ghosh
- NSHM College of Pharmaceutical Technology, NSHM Knowledge Campus, Kolkata Group of Institutions, 124 BL Saha Road, Kolkata-700053, West Bengal, India.
| |
Collapse
|
5
|
Extraction of Iron from the Rabbit Anterior Chamber with Reverse Iontophoresis. J Ophthalmol 2015; 2015:425438. [PMID: 26257921 PMCID: PMC4518192 DOI: 10.1155/2015/425438] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Accepted: 07/02/2015] [Indexed: 12/24/2022] Open
Abstract
Ocular siderosis is a common eye disease caused by retention of an iron-containing intraocular foreign body in the eye. Iron-containing intraocular foreign bodies may cause severe inflammatory reaction and affect visual function. Currently the optimal treatment method of ocular siderosis is a moot point. This study used the reverse iontophoresis technique to noninvasively extract iron from the rabbit anterior chamber. By slit lamp observation and histological examination, reverse iontophoresis treatment has a good effect on ocular siderosis. Reverse iontophoresis seems to be a noninvasive and promising approach to extract iron from the anterior chamber to treat ocular siderosis.
Collapse
|
6
|
Paliwal S, Hwang BH, Tsai KY, Mitragotri S. Diagnostic opportunities based on skin biomarkers. Eur J Pharm Sci 2013; 50:546-56. [DOI: 10.1016/j.ejps.2012.10.009] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2012] [Revised: 10/14/2012] [Accepted: 10/17/2012] [Indexed: 12/20/2022]
|
7
|
Ching CTS, Fu LS, Sun TP, Hsu TH, Chang KM. Use of electroporation and reverse iontophoresis for extraction of transdermal multibiomarkers. Int J Nanomedicine 2012; 7:885-94. [PMID: 22393288 PMCID: PMC3289445 DOI: 10.2147/ijn.s27421] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Monitoring of biomarkers, like urea, prostate-specific antigen (PSA), and osteopontin, is very important because they are related to kidney disease, prostate cancer, and ovarian cancer, respectively. It is well known that reverse iontophoresis can enhance transdermal extraction of small molecules, and even large molecules if reverse iontophoresis is used together with electroporation. Electroporation is the use of a high-voltage electrical pulse to create nanochannels within the stratum corneum, temporarily and reversibly. Reverse iontophoresis is the use of a small current to facilitate both charged and uncharged molecule transportation across the skin. The objectives of this in vitro study were to determine whether PSA and osteopontin are extractable transdermally and noninvasively and whether urea, PSA, and osteopontin can be extracted simultaneously by electroporation and reverse iontophoresis. Methods All in vitro experiments were conducted using a diffusion cell assembled with the stratum corneum of porcine skin. Three different symmetrical biphasic direct currents (SBdc), five various electroporations, and a combination of the two techniques were applied to the diffusion cell via Ag/AgCl electrodes. The three different SBdc had the same current density of 0.3 mA/cm2, but different phase durations of 0 (ie, no current, control group), 30, and 180 seconds. The five different electroporations had the same pulse width of 1 msec and number of pulses per second of 10, but different electric field strengths of 0 (ie, no voltage, control group), 74, 148, 296, and 592 V/cm. Before and after each extraction experiment, skin impedance was measured at 20 Hz. Results It was found that urea could be extracted transdermally using reverse iontophoresis alone, and further enhancement of extraction could be achieved by combined use of electroporation and reverse iontophoresis. Conversely, PSA and osteopontin were found to be extracted transdermally only by use of reverse iontophoresis and electroporation with a high electrical field strength (>296 V/cm). After application of reverse iontophoresis, electroporation, or a combination of the two techniques, a reduction in skin impedance was observed. Conclusion Simultaneous transdermal extraction of urea, PSA, and osteopontin is possible only for the condition of applying reverse iontophoresis in conjunction with high electroporation.
Collapse
Affiliation(s)
- Congo Tak-Shing Ching
- Department of Electrical Engineering, National Chi Nan University, Puli, Nantou County.
| | | | | | | | | |
Collapse
|
8
|
An evaluation of a cultured human corneal epithelial tissue model for the determination of the ocular irritation potential of pharmaceutical process materials. Toxicol In Vitro 2010; 24:1862-70. [DOI: 10.1016/j.tiv.2010.03.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2009] [Revised: 02/04/2010] [Accepted: 03/07/2010] [Indexed: 11/21/2022]
|
9
|
|
10
|
Patlolla RR, Mallampati R, Fulzele SV, Babu RJ, Singh M. Dermal microdialysis of inflammatory markers induced by aliphatic hydrocarbons in rats. Toxicol Lett 2008; 185:168-74. [PMID: 19152832 DOI: 10.1016/j.toxlet.2008.12.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2008] [Revised: 12/15/2008] [Accepted: 12/16/2008] [Indexed: 11/17/2022]
Abstract
In the present study we made an attempt to understand the skin irritation cascade of selected aliphatic hydrocarbons using microdialysis technique. Microdialysis probes were inserted into dermis in the dorsal skin of hairless rats. After 2h of probes insertion, occlusive dermal exposure (2h) was carried out with 230 microl of nonane, dodecane and tetradecane, using Hill top chambers((R)). Inflammatory biomarkers such as substance P (SP), alpha-melanocyte stimulating hormone (alpha-MSH) Interleukin 6 (IL-6) and prostaglandin E2 (PGE(2)) were analyzed in the dialysis samples by enzyme immunoassay (EIA). SP, alpha-MSH and IL6 were released in significant amounts following the dermal exposure of nonane and dodecane, whereas tetradecane did not induce any of these markers in significant amounts compared to control. Nonane increased the PGE(2) levels in significant amounts within 2h of chemical exposure compared to dodecane and tetradecane. IL-6 response was found to be slow and 2-3-fold increase in IL-6 levels was observed after 5h following nonane and dodecane application. The magnitude of skin irritation exerted by all three chemicals was in the order of nonane>or=dodecane>or=tetradecane. The results demonstrate that microdialysis can be used to measure the inflammatory biomarkers in the skin irritation studies and irritation response of chemicals was quantifiable by this method. In conclusion, microdialysis was found to be an excellent tool to measure several inflammatory biomarkers as a function of time after dermal exposures with irritant chemicals.
Collapse
Affiliation(s)
- Ram R Patlolla
- College of Pharmacy and Pharmaceutical Sciences, Florida A&M University, Tallahassee, FL 32307, USA
| | | | | | | | | |
Collapse
|
11
|
Ching TS, Connolly P. Simultaneous transdermal extraction of glucose and lactate from human subjects by reverse iontophoresis. Int J Nanomedicine 2008; 3:211-23. [PMID: 18686780 PMCID: PMC2527667 DOI: 10.2147/ijn.s1728] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
This study investigated the possibility of simultaneously extracting glucose and lactate from human subjects, at the same skin location, using transdermal reverse iontophoresis. Transdermal monitoring using iontophoresis is made possible by the skin’s permeability to small molecules and the nanoporous and microporous nature of the structure of skin. The study was intended to provide information which could be used to develop a full, biosensor-based, monitoring system for multiple parameters from transdermal extraction. As a precursor to the human study, in vitro reverse iontophoresis experiments were performed in an artificial skin system to establish the optimum current waveforms to be applied during iontophoresis. In the human study, a bipolar DC current waveform (with reversal of the electrode current direction every 15 minutes) was applied to ten healthy volunteers via skin electrodes and utilized for simultaneous glucose and lactate transdermal extraction at an applied current density of 300 μA/cm2. Glucose and lactate were successfully extracted through each subject’s skin into the conducting gel that formed part of each iontophoresis electrode. The results suggest that it will be possible to noninvasively and simultaneously monitor glucose and lactate levels in patients using this approach and this could have future applications in diagnostic monitoring for a variety of medical conditions.
Collapse
|
12
|
Fulzele SV, Babu RJ, Ahaghotu E, Singh M. Estimation of proinflammatory biomarkers of skin irritation by dermal microdialysis following exposure with irritant chemicals. Toxicology 2007; 237:77-88. [PMID: 17574719 DOI: 10.1016/j.tox.2007.05.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2007] [Revised: 04/26/2007] [Accepted: 05/01/2007] [Indexed: 11/20/2022]
Abstract
The aim of the present study was to quantify the release of proinflammatory biomarkers by dermal microdialysis after topical exposure with irritant chemicals, Jet fuel (JP-8) and xylene in rat skin. Occlusive dermal exposure (2h) was carried out with 230microl of JP-8 or xylene using Hill top chambers((R)). Linear microdialysis probes (10mm) were inserted in the dermis under urethane anesthesia. The dialysis fluid was pumped at a flow rate of 2microl/min and the dialysate was collected for 7h following probe insertion. The expression of substance P (SP), calcitonin-gene related peptide (CGRP) and prostaglandin E(2) (PGE(2)) in the dialysate following microdialysis was measured by enzyme immunoassay (EIA). The effect of pretreatment with an SP antagonist (SR-140333) and a PGE(2) inhibitor (celecoxib), 6 and 18h before the application of JP-8 was also assessed to further establish the sensitivity of the microdialysis set up. On similar lines, untreated and capsaicin treated control experiments were performed to compare with the SP release following JP-8 treatment. Further, we also investigated the SP release following topical application of xylene. The mean concentrations of SP after the application of JP-8 (90.01+/-3.31) and 3h after its removal (58.66+/-9.36) indicated that JP-8 induced significantly higher release of SP as compared to the baseline value (P<0.05). The release of SP following JP-8 treatment (58.66+/-9.36pg/ml) was comparable to capsaicin (58.18+/-11.29pg/ml). JP-8 exposure resulted in a significant increase (P<0.001) in PGE(2) levels over the baseline control at the end of 1 and 2h of exposure. JP-8 treatment also produced significant increase (P<0.001) in PGE(2) levels as compared to the untreated control during occlusion and 1h following its removal. There was a significant drop (P<0.05) in the PGE(2) levels by the end of 3h following exposure. Pretreatment with SR-140333 and celecoxib significantly reduced (P<0.05) SP and PGE(2) release induced by JP-8. The mean concentrations of SP following xylene exposure (25.50+/-8.80pg/ml) and 3h after its removal (34.37+/-5.61pg/ml) indicated its skin irritation potential. Unlike JP-8, xylene produced a significant increase in SP release only after the removal of occlusion. Pretreatment with SR-140333 significantly blocked the xylene induced SP release. CGRP was not detected in any of the samples. This study demonstrates that dermal microdialysis can be used to quantify skin irritation potential of JP-8 and related irritant chemicals.
Collapse
Affiliation(s)
- Suniket V Fulzele
- College of Pharmacy and Pharmaceutical Sciences. Florida A&M University, Tallahassee, FL 32307, USA
| | - R J Babu
- Harrison School of Pharmacy, Auburn University, Auburn, AL 36849, USA
| | - E Ahaghotu
- College of Pharmacy and Pharmaceutical Sciences. Florida A&M University, Tallahassee, FL 32307, USA
| | - Mandip Singh
- College of Pharmacy and Pharmaceutical Sciences. Florida A&M University, Tallahassee, FL 32307, USA.
| |
Collapse
|
13
|
Sung YM, He G, Fischer SM. Lack of expression of the EP2 but not EP3 receptor for prostaglandin E2 results in suppression of skin tumor development. Cancer Res 2005; 65:9304-11. [PMID: 16230392 DOI: 10.1158/0008-5472.can-05-1015] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The EP2 receptor for prostaglandin E2 (PGE2) is a membrane receptor that mediates at least part of the action of PGE2. It has been shown that EP2 plays a critical role in tumorigenesis in mouse mammary gland and colon. However, the possibility that the EP2 receptor is involved in the development of skin tumors was unknown. The purpose of this study was to investigate the role of the EP2 receptor in mouse skin carcinogenesis. Unlike EP3 knockout mice, the EP2 knockout mice produced significantly fewer tumors and reduced tumor incidence compared with wild type (WT) mice in a 7,12-dimethylbenz(a)anthracene (DMBA)/12-O-tetradecanoylphorbol-13-acetate (TPA) two-stage carcinogenesis protocol. EP2 knockout mice had significantly reduced cellular proliferation of mouse skin keratinocytes in vivo and in vitro compared with that in WT mice. In addition, the epidermis of EP2 knockout mice 48 hours after topical TPA treatment was significantly thinner compared with that of WT mice. The inflammatory response to TPA was reduced in EP2 knockout mice, based on a reduced number of macrophages in the dermis and a reduced level of interleukin-1alpha mRNA expression, compared with WT mice. EP2 knockout mice also had significantly reduced epidermal cyclic AMP levels after PGE2 treatment compared with WT mice. Tumors from WT mice produced more blood vessels and fewer apoptotic cells than those of EP2 knockout mice as determined by immunohistochemical staining. Our data suggest that the EP2 receptor plays a significant role in the protumorigenic action of PGE2 in skin tumor development.
Collapse
MESH Headings
- 9,10-Dimethyl-1,2-benzanthracene
- Animals
- Apoptosis/genetics
- Apoptosis/physiology
- Carcinogens
- Cell Growth Processes/drug effects
- Cell Growth Processes/physiology
- Cell Transformation, Neoplastic/drug effects
- Cell Transformation, Neoplastic/metabolism
- Cyclic AMP/metabolism
- Dinoprostone/metabolism
- Dinoprostone/pharmacology
- Drug Eruptions/genetics
- Drug Eruptions/metabolism
- Drug Eruptions/pathology
- Female
- Hyperplasia
- Keratinocytes/drug effects
- Keratinocytes/metabolism
- Mice
- Mice, Knockout
- Neovascularization, Pathologic/metabolism
- Neovascularization, Pathologic/pathology
- Receptors, Prostaglandin E/biosynthesis
- Receptors, Prostaglandin E/deficiency
- Receptors, Prostaglandin E/genetics
- Receptors, Prostaglandin E, EP2 Subtype
- Receptors, Prostaglandin E, EP3 Subtype
- Skin/drug effects
- Skin/metabolism
- Skin/pathology
- Skin Neoplasms/blood supply
- Skin Neoplasms/chemically induced
- Skin Neoplasms/metabolism
- Tetradecanoylphorbol Acetate
Collapse
Affiliation(s)
- You Me Sung
- The University of Texas M.D. Anderson Cancer Center, Science Park-Research Division, Smithville, TX 78957, USA
| | | | | |
Collapse
|
14
|
Leboulanger B, Guy RH, Delgado-Charro MB. Reverse iontophoresis for non-invasive transdermal monitoring. Physiol Meas 2004; 25:R35-50. [PMID: 15253111 DOI: 10.1088/0967-3334/25/3/r01] [Citation(s) in RCA: 98] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Iontophoresis is the application of a small electric current to enhance the transport of both charged and polar, neutral compounds across the skin. Manipulation of either the total charge delivered and/or certain electrode formulation parameters allows control of electromigration and electroosmosis, the two principal mechanisms of transdermal iontophoresis. While the approach has been mainly used for transdermal drug delivery, 'reverse iontophoresis', by which substances are extracted to the skin surface, has recently been the subject of considerable effort. Glucose monitoring has been extensively studied and other applications, including therapeutic drug monitoring, are contributing to the development of the technique. An internal standard calibration procedure may ultimately render this novel monitoring technique completely non-invasive.
Collapse
Affiliation(s)
- Benoît Leboulanger
- School of Pharmacy, University of Geneva, 30. Quai Ernest-Ansermet CH-1211 Geneva 4, Switzerland
| | | | | |
Collapse
|
15
|
Abstract
Transdermal iontophoresis is the administration of ionic therapeutic agents through the skin by the application of a low-level electric current. This article presents an overview of transdermal iontophoretic delivery of drugs, including peptides and oligonucleotides. Recent advances in the area of iontophoretic delivery, including devices, hydrogel formulations, safety, clinical relevance and future prospects, are discussed. Electroporation, another method of electrically assisted drug delivery, is also briefly reviewed. Transdermal iontophoresis appears to be a promising technique for the delivery of a variety of compounds in a controlled and preprogrammed manner. Transdermal iontophoresis would be particularly useful in the delivery of hydrophilic drugs produced by biotechnology (peptides and oligonucleotides). However, because of the complex physicochemical properties of peptides, many factors must be carefully considered for the proper design of an iontophoretic drug delivery system for peptides. Iontophoresis has been successfully used in the delivery of small peptides, such as leuprolide and calcitonin analogues, in humans. However, it appears that transdermal iontophoresis may not be a suitable method for the systemic delivery of larger peptides (>7,000D). The combined use of iontophoresis and electroporation may be more effective in the delivery of peptides, proteins, genes and oligonucleotides. The long-term safety of iontophoresis, patient compliance with the technique and the commercial success of this technology are yet to be demonstrated. Iontophoretic delivery of drugs would be beneficial in the treatment of certain skin disorders such as skin cancer, psoriasis, dermatitis, venous ulcers, keloid and hypertrophic scars. Investigations on reverse iontophoresis may yield interesting results that would be useful in the noninvasive measurement of clinically important molecules in the body.
Collapse
Affiliation(s)
- Narayanasamy Kanikkannan
- Division of Pharmaceutics, College of Pharmacy, Florida A & M University, Tallahassee, Florida, USA.
| |
Collapse
|
16
|
Abstract
Iontophoresis evolved as a transdermal enhancement technique in the 20th century, primarily for the delivery of large and charged molecules. Significant achievements have been made in the understanding of underlying mechanisms of iontophoresis and these have contributed to the rational development of iontophoretic delivery systems. The major challenges in this area are the development of portable, cost effective devices and suitable semi-solid formulations that are compatible with the device and the skin. Some of the obstacles in transdermal iontophoresis can be overcome by combining iontophoresis with other physical and chemical enhancement techniques for the delivery of macromolecules. Iontophoresis also offers an avenue for extracting information from the body through the use of reverse iontophoresis, which has potential application in diagnosis and monitoring. The current research is focussed towards resolving the skin toxicity issues and other problems in order to make this technology a commercial reality.
Collapse
Affiliation(s)
- R Panchagnula
- Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Punjab, India.
| | | | | | | |
Collapse
|
17
|
Stagni G, O'Donnell D, Liu YJ, Kellogg DL, Shepherd AM. Iontophoretic current and intradermal microdialysis recovery in humans. J Pharmacol Toxicol Methods 1999; 41:49-54. [PMID: 10507758 DOI: 10.1016/s1056-8719(99)00027-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
When microdialysis (MD) is used to study dermal delivery by iontophoresis, the effects of current may alter MD recovery through an increase in temperature, a change of pH, hyperemia, and dermal hydration. The objective of this work is to assess whether these effects of current may cause a measurable change in the retrodialysis of a model compound (sodium fluorescein, Fl). Two linear MD-probes were inserted in the forearm dermis of healthy human volunteers and perfused with Ringer's solution containing Fl. Two identical iontophoresis chambers (IC, filled with NaCl in propylene glycol) were placed over the MD-probes. Each IC included a laser Doppler flowmetry probe to monitor skin blood flow. At one IC, current was applied for two periods of 30 min each, separated by 30 min of no current. No current was applied to the control site. Dialysate samples were collected every 5 min and analyzed for Fl by HPLC. Skin blood flow increased in response to iontophoresis, on average, 570% compared to the control site. However, there was no difference in the recovery of Fl between the current-active site versus the control site, and between the period with applied current versus the period with no current. In conclusion, iontophoretic current did not affect intradermal MD recovery.
Collapse
Affiliation(s)
- G Stagni
- Department of Pharmacology, University of Texas Health Science Center at San Antonio, 78284-6205, USA.
| | | | | | | | | |
Collapse
|