Hubble CL, Gentile MA, Tripp DS, Craig DM, Meliones JN, Cheifetz IM. Deadspace to tidal volume ratio predicts successful extubation in infants and children.
Crit Care Med 2000;
28:2034-40. [PMID:
10890660 DOI:
10.1097/00003246-200006000-00059]
[Citation(s) in RCA: 94] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE
Using a modification of the Bohr equation, single-breath carbon dioxide capnography is a noninvasive technology for calculating physiologic dead space (V(D)/V(T)). The objective of this study was to identify a minimal V(D)/V(T) value for predicting successful extubation from mechanical ventilation in pediatric patients.
DESIGN
Prospective, blinded, clinical study.
SETTING
Medical and surgical pediatric intensive care unit of a university hospital.
PATIENTS
Intubated children ranging in age from 1 wk to 18 yrs.
INTERVENTIONS
None.
MEASUREMENTS AND MAIN RESULTS
Forty-five patients were identified by the pediatric intensive care unit clinical team as meeting criteria for extubation. Thirty minutes before the planned extubation, each patient was begun on pressure support ventilation set to deliver an exhaled tidal volume of 6 mL/kg. After 20 mins on pressure support ventilation, an arterial blood gas was obtained, V(D)/V(T) was calculated, and the patient was extubated. Over the next 48 hrs, the clinical team managed the patient without knowledge of the preextubation V(D)/V(T) value. Of the 45 patients studied, 25 had V(D)/V(T) < or =0.50. Of these patients, 24 of 25 (96%) were successfully extubated without needing additional ventilatory support. In an intermediate group of patients with V(D)/V(T) between 0.50 and 0.65, six of ten patients (60%) successfully extubated from mechanical ventilation. However, only two of ten patients (20%) with a V(D)/V(T) > or =0.65 were successfully extubated. Logistic regression analysis revealed a significant association between lower V(D)/V(T) and successful extubation.
CONCLUSIONS
A V(D)/V(T) < or =0.50 reliably predicts successful extubation, whereas a V(D)/V(T) >0.65 identifies patients at risk for respiratory failure following extubation. There appears to be an intermediate V(D)/V(T) range (0.51-0.65) that is less predictive of successful extubation. Routine V(D)/V(T) monitoring of pediatric patients may permit earlier extubation and reduce unexpected extubation failures.