1
|
Clemence P, Moshiro R, Manji K. Validity of BiliDx as a point-of-care bilirubin measurement device to diagnose and monitor neonatal jaundice at Muhimbili National Hospital, an observational study. BMC Pediatr 2024; 24:114. [PMID: 38350890 PMCID: PMC10863160 DOI: 10.1186/s12887-024-04565-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 01/14/2024] [Indexed: 02/15/2024] Open
Abstract
BACKGROUND Neonatal jaundice is a condition caused by elevated levels of bilirubin in the bloodstream. Laboratory determination of serum bilirubin concentration by total serum bilirubin (TSB) test is still considered as gold standard for clinical guidance and practice. In developed countries, diagnosis of neonatal jaundice is shifting towards point-of-care medical devices. BiliDx is a device developed to allow a fast, blood-based determination of bilirubin levels at the point of care. This study aimed to determine the accuracy of the BiliDx device relative to a standard laboratory total serum bilirubin to diagnose and monitor jaundice among neonates admitted at Muhimbili National Hospital (MNH). MATERIAL AND METHODOLOGY This was a prospective hospital-based observational study conducted at the Neonatal Ward - MNH, Dar-es-Salaam, Tanzania from November 2022 to January 2023. A total of 180 neonates admitted at the neonatal ward with jaundice and whose parents consented were enrolled in the study. Blood samples were collected; 2 ml of venous blood into the vacutainer bottle for standard laboratory measurement of total serum bilirubin (TSB) and 25µL blood collected into a transfer pipette tube and applied to BiliDx. STATA version 15.1 was used for data analysis. RESULTS Out of 180 neonates, 39.4% (71/180) had birth weight between 1500 - 2499.9 g, approximately 2/3rd (120/180) were preterm, 92/180 (51.1%) were males and 100/180 (55.6%) were undergoing phototherapy treatment the moment sample taken. The mean bilirubin concentration was 92 mmol/l for BiliDx and 118 mmol/l for standard laboratory TSB. The minimum and maximum values obtained with BiliDx were, 3.4 and 427.5 mmol/l respectively, compared with 10.7 and 382.1 mmol/l using standard laboratory TSB. A linear relationship and correlation coefficient of 0.8408 (p = 0.000) between BiliDx and standard laboratory TSB was found. The regression analysis showed the presence of constant error [coefficient of BiliDx/slope = 0.91, 95% CI (0.82-0.99), p = 0.000] and random error exclusively [coefficient of constant/y-intercept = 48.52, 95%CI (37.70-59.34), p = 0.000]. The Bland-Altman plot showed an acceptable mean difference of 39.1mmol/l, limits of agreement of -48.3mmol/l to 126.4mmol/l, and 179 points (179/180 = 99.4%) lying inside the limits of agreement. CONCLUSION The results support the use of BiliDx for rapid and accurate testing of elevated levels of bilirubin in the bloodstream among neonates since 99.4% of the differences between BiliDx and standard laboratory TSB lie between the lines of agreement.
Collapse
Affiliation(s)
- Pascal Clemence
- Department of Paediatrics and child health, Muhimbili University of Health and Allied Sciences, P.O BOX 65001, Dar es Salaam, Tanzania.
| | - Robert Moshiro
- Department of Paediatrics and Child Health, Muhimbili National Hospital, P.O BOX 65000, Dar es Salaam, Tanzania
| | - Karim Manji
- Department of Paediatrics and child health, Muhimbili University of Health and Allied Sciences, P.O BOX 65001, Dar es Salaam, Tanzania
| |
Collapse
|
2
|
Okwundu CI, Olowoyeye A, Uthman OA, Smith J, Wiysonge CS, Bhutani VK, Fiander M, Gautham KS. Transcutaneous bilirubinometry versus total serum bilirubin measurement for newborns. Cochrane Database Syst Rev 2023; 5:CD012660. [PMID: 37158489 PMCID: PMC10167941 DOI: 10.1002/14651858.cd012660.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
BACKGROUND Jaundice is a very common condition in newborns, affecting up to 60% of term newborns and 80% of preterm newborns in the first week of life. Jaundice is caused by increased bilirubin in the blood from the breakdown of red blood cells. The gold standard for measuring bilirubin levels is obtaining a blood sample and processing it in a laboratory. However, noninvasive transcutaneous bilirubin (TcB) measurement devices are widely available and used in many settings to estimate total serum bilirubin (TSB) levels. OBJECTIVES To determine the diagnostic accuracy of transcutaneous bilirubin measurement for detecting hyperbilirubinaemia in newborns. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, CINAHL and trial registries up to 18 August 2022. We also checked the reference lists of all included studies and relevant systematic reviews for other potentially eligible studies. SELECTION CRITERIA We included cross-sectional and prospective cohort studies that evaluated the accuracy of any TcB device compared to TSB measurement in term or preterm newborn infants (0 to 28 days postnatal age). All included studies provided sufficient data and information to create a 2 × 2 table for the calculation of measures of diagnostic accuracy, including sensitivities and specificities. We excluded studies that only reported correlation coefficients. DATA COLLECTION AND ANALYSIS Two review authors independently applied the eligibility criteria to all citations from the search and extracted data from the included studies using a standard data extraction form. We summarised the available results narratively and, where possible, we combined study data in a meta-analysis. MAIN RESULTS We included 23 studies, involving 5058 participants. All studies had low risk of bias as measured by the QUADAS 2 tool. The studies were conducted in different countries and settings, included newborns of different gestational and postnatal ages, compared various TcB devices (including the JM 101, JM 102, JM 103, BiliChek, Bilitest and JH20-1C) and used different cutoff values for a positive result. In most studies, the TcB measurement was taken from the forehead, sternum, or both. The sensitivity of various TcB cutoff values to detect significant hyperbilirubinaemia ranged from 74% to 100%, and specificity ranged from 18% to 89%. AUTHORS' CONCLUSIONS The high sensitivity of TcB to detect hyperbilirubinaemia suggests that TcB devices are reliable screening tests for ruling out hyperbilirubinaemia in newborn infants. Positive test results would require confirmation through serum bilirubin measurement.
Collapse
Affiliation(s)
- Charles I Okwundu
- Centre for Evidence-based Health Care, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Abiola Olowoyeye
- Phoenix Children's Hospital and University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Olalekan A Uthman
- Warwick Centre for Applied Health Research and Delivery (WCAHRD), Division of Health Sciences, Warwick Medical School, The University of Warwick, Coventry, UK
| | - Johan Smith
- Department of Paediatrics and Child Health, Stellenbosch University, Faculty of Health Sciences, Stellenbosch, South Africa
| | - Charles S Wiysonge
- Cochrane South Africa, South African Medical Research Council, Cape Town, South Africa
| | - Vinod K Bhutani
- Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford School of Medicine, Lucile Packard Children's Hospital, Palo Alto, California, USA
| | | | - Kanekal S Gautham
- Chair of Pediatrics and Pediatrician-in-Chief, Nemours Children's Health System, University of Central Florida College of Medicine, Orlando, Florida, USA
| |
Collapse
|
3
|
Transcutaneous bilirubin measurements: useful, but also reproducible? Pediatr Res 2021; 89:725-726. [PMID: 33173170 DOI: 10.1038/s41390-020-01242-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 10/13/2020] [Indexed: 11/09/2022]
|
4
|
Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors. Sci Rep 2020; 10:11149. [PMID: 32636410 PMCID: PMC7341797 DOI: 10.1038/s41598-020-67981-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Accepted: 06/11/2020] [Indexed: 11/08/2022] Open
Abstract
The study was aimed to evaluate the performance of a newly developed non-invasive and non-contact bilirubin measurement device (AJO-Neo) as an alternative to the conventional invasive biochemical method of total serum bilirubin (TSB) estimation in preterm and term neonates suffering from hyperbilirubinemia associated with risk factors, and/or undergoing phototherapy. The safety and efficacy of the device were assessed in 1968 neonates with gestational ages ranging from 28 to 41 weeks and suffering from incidences of hyperbilirubinemia. Linear regression analysis showed a good correlation between AJO-Neo and the conventional method of TSB (Pearson’s coefficient, r = 0.79). The small bias (0.27 mg/dL) and limits of agreements (− 3.44 to 3.99 mg/dL) were within the range of clinical acceptance. The device was also precise in the measurement of bilirubin levels in all subgroups of the study. The receiver operator curve (ROC), that takes account of both sensitivity and specificity of a device showed high efficacy of the device (area under the curve, AUC = 0.83) in the detection of bilirubin. While monitoring the bilirubin level during phototherapy, the device indicated promising results showing good agreement with TSB. Specificities and sensitivities of the device indicated a much higher accuracy in neonates with associated risk factors for hyperbilirubinemia. Hence, the newly developed device (AJO-Neo) is reliable in measuring bilirubin level in preterm, and term neonates irrespective of gestational or postnatal age, sex, risk factors, feeding behavior or skin color.
Collapse
|
5
|
Starowicz O, Edwards P, Schmidt P, Birch P. Evaluation of the Kejian KJ-8000 bilirubinometer in an Australian setting. J Paediatr Child Health 2020; 56:283-288. [PMID: 31464033 DOI: 10.1111/jpc.14597] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2018] [Revised: 06/28/2019] [Accepted: 07/20/2019] [Indexed: 11/27/2022]
Abstract
AIM To evaluate the accuracy of the Kejian 8000 (KJ-8000) transcutaneous bilirubinometer in infants of differing ethnicity and gestational age. METHODS This was a prospective study of infants in the Newborn Care Unit at Gold Coast University Hospital. Transcutaneous bilirubin (TcB) and serum bilirubin (SBR) results were compared using linear regression and a Bland-Altman plot. Predicted indices were calculated to assess the KJ-8000 as a screening tool using local jaundice management guidelines. RESULTS A total of 416 paired samples were collected from 201 infants. There was a strong correlation between TcB and SBR with a Pearson correlation coefficient of 0.8 (<0.00001). The bias was -5.9 μmol/L (95% confidence interval: -101, 89). The bias was not evenly spread, with the KJ-8000 tending to underestimate at higher SBR levels. Infants <32 weeks' gestation had a poor correlation of 0.48. Non-Caucasian infants were more likely to have TcB overestimation, and measurements were less precise. As a screening tool using local guidelines, the KJ-8000 had a sensitivity, specificity, positive predictive value and negative predictive value of 83, 53, 20 and 96%, respectively, and is predicted to avoid blood tests in 48% of infants screened. CONCLUSIONS In this study, the correlation and agreement of TcB measurements using the KJ-8000 were not as good as has been reported with other more studied devices but may still have value as a screening tool. The poor correlation in preterm infants suggests that use should be restricted to term infants. The overall results of this study are affected by an underrepresentation of term infants, and so, further clinical assessment of this device should be undertaken before it can be recommended for widespread use.
Collapse
Affiliation(s)
- Olivia Starowicz
- Newborn Care Unit, Gold Coast University Hospital, Gold Coast, Queensland, Australia
| | - Philippa Edwards
- Newborn Care Unit, Gold Coast University Hospital, Gold Coast, Queensland, Australia
| | - Peter Schmidt
- Newborn Care Unit, Gold Coast University Hospital, Gold Coast, Queensland, Australia
| | - Pita Birch
- Department of Neonatology, Mater Health Services, Brisbane, Queensland, Australia
| |
Collapse
|
6
|
Hulzebos CV, Vader-van Imhoff DE, Bos AF, Dijk PH. Should transcutaneous bilirubin be measured in preterm infants receiving phototherapy? The relationship between transcutaneous and total serum bilirubin in preterm infants with and without phototherapy. PLoS One 2019; 14:e0218131. [PMID: 31199817 PMCID: PMC6568417 DOI: 10.1371/journal.pone.0218131] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Accepted: 05/25/2019] [Indexed: 01/22/2023] Open
Abstract
Our objective was to analyze the relationship between transcutaneous bilirubin (TcB) measured on an unexposed area of skin and total serum bilirubin (TSB) in preterm infants before, during, and after phototherapy (PT). For this purpose paired TSB and TcB levels were measured daily during the first ten days after birth in preterm infants of less than 32 weeks’ gestation. TcB was measured with a Dräger Jaundice Meter JM-103 on the covered hipbone. Agreement between TSB and TcB levels was assessed before, during, and after PT. True negative and corresponding false negative percentages were calculated using different TcB cut-off levels. Data are presented as mean (±SD). We obtained 856 paired TcB and TSB levels in 109 preterm infants (66 boys, gestational age 29.4 ± 1.6 weeks and birth weight 1282 g ± 316 g). We found that the difference between TSB and TcB before PT was significantly lower, 44 (±36) μmol/L, than the difference during and after PT, 61 (±29) μmol/L and 63 (±25) μmol/L, respectively; P < 0.01. Blood sampling could be reduced by 42%, with 2% false negatives, when 50 μmol/L was added to the TcB level at 70% of the PT threshold. Our conclusion is that phototherapy enhances underestimation of TSB by TcB in preterms, even if measured on unexposed skin. The use of specific TcB cut-off levels substantially reduces the need for TSB measurements.
Collapse
Affiliation(s)
- Christian V. Hulzebos
- Department of Pediatrics, Division of Neonatology, Beatrix Children’s Hospital, University Medical Center Groningen, Groningen, the Netherlands
- * E-mail:
| | - Deirdre E. Vader-van Imhoff
- Department of Pediatrics, Division of Neonatology, Beatrix Children’s Hospital, University Medical Center Groningen, Groningen, the Netherlands
| | - Arend F. Bos
- Department of Pediatrics, Division of Neonatology, Beatrix Children’s Hospital, University Medical Center Groningen, Groningen, the Netherlands
| | - Peter H. Dijk
- Department of Pediatrics, Division of Neonatology, Beatrix Children’s Hospital, University Medical Center Groningen, Groningen, the Netherlands
| |
Collapse
|
7
|
Munkholm SB, Krøgholt T, Ebbesen F, Szecsi PB, Kristensen SR. The smartphone camera as a potential method for transcutaneous bilirubin measurement. PLoS One 2018; 13:e0197938. [PMID: 29856793 PMCID: PMC5983497 DOI: 10.1371/journal.pone.0197938] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 04/01/2018] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND Hyperbilirubinemia is a common problem in neonates that can progress into kernicterus. Suspected neonatal hyperbilirubinemia is a common reason for contact with the healthcare system. The severity and management of jaundice are determined based on estimated bilirubin levels. However, no easy and accessible tool for self-assessing neonatal jaundice is currently available. Smartphones could potentially be transformed into a medical device that could be used by both patients and practitioners. OBJECTIVE To investigate whether a digital image produced by a camera embedded on a smartphone can be a used as a screening tool for neonatal hyperbilirubinemia. STUDY DESIGN A total of 64 randomly selected newborns were enrolled. The inclusion criteria were healthy Caucasians, gestational age >35 weeks, age >24 hours and ≤14 days old, and parental informed consent. The exclusion criteria were facial skin lesions and light treatment. Images of the glabella were obtained with an iPhone 6 via i) directly applied pressure, ii) a dermatoscope, or iii) a dermatoscope equipped with a Wratten No. 11 filter. The red, green and blue colour intensities of each image were compared to bilirubin levels. RESULTS Only the dermatoscope-acquired intensities of the green and blue channels were significantly correlated (p < 0.001) with bilirubin measurements (Pearson's r: 0.59 and 0.48, respectively). For the green and blue channels, discrimination limits of 212 and 190, respectively, revealed a sensitivity and specificity of 100% and 62.5%, respectively, for green and 90.9% and 60%, respectively, for blue for a plasma bilirubin above 205 μmol/L. CONCLUSIONS The results of this study indicate that a smartphone equipped with a consistent light source in the form of a dermatoscope may be a simple screening tool for neonatal hyperbilirubinemia. However, the method requires some improvement before clinical application.
Collapse
Affiliation(s)
- Sarah B. Munkholm
- Department of Acute Medicine, Randers Regional Hospital, Randers, Denmark
| | | | - Finn Ebbesen
- Department of Paediatrics, Aalborg University Hospital, Aalborg, Denmark
| | - Pal B. Szecsi
- Department of Clinical Biochemistry, Copenhagen University Hospital Holbæk, Holbæk, Denmark
| | - Søren R. Kristensen
- Department of Clinical Biochemistry, Aalborg University Hospital, Aalborg, Denmark
| |
Collapse
|
8
|
Kalvandi GR, Shahramian I, Delaramnasab M, Jozaei M. Transcutaneous Bilirubin Assessment for Screening of Hyperbilirubinemia in Term and Near-Term Neonates with Jaundice, a Comparative Study. INTERNATIONAL JOURNAL OF BASIC SCIENCE IN MEDICINE 2017. [DOI: 10.15171/ijbsm.2017.27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
9
|
Comparison between Bilistick System and transcutaneous bilirubin in assessing total bilirubin serum concentration in jaundiced newborns. J Perinatol 2017; 37:1028-1031. [PMID: 28617429 DOI: 10.1038/jp.2017.94] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Revised: 05/11/2017] [Accepted: 05/12/2017] [Indexed: 01/01/2023]
Abstract
OBJECTIVE To compare the performance and accuracy of the JM-103 transcutaneous bilirubinometer and Bilistick System in measuring total serum bilirubin for the early identification of neonatal hyperbilirubinemia. STUDY DESIGN The study was performed on 126 consecutive term and near-term (⩾36 weeks' gestational age) jaundiced newborns in Cairo University Children Hospital NICU, Egypt. Total serum bilirubin was assayed concurrently by the clinical laboratory and Bilistick System and estimated using the JM-103 transcutaneous bilirubin instrument. Bland-Altman analysis was used to evaluate the agreement between determinations. RESULT The limits of agreement of the Bilistick System (-5.8 to 3.3 mg dl-1) and JM-103 system (-5.4 to 6.0 mg dl-1) versus the clinical laboratory results were similar. CONCLUSION The Bilistick System is an accurate alternative to transcutaneous (TcB) determination for early diagnosis and proper management of the neonatal jaundice.
Collapse
|
10
|
Cucuy M, Juster-Reicher A, Flidel O, Shinwell E. Correlation between transcutaneous and serum bilirubin in preterm infants before, during, and after phototherapy. J Matern Fetal Neonatal Med 2017; 31:1323-1326. [DOI: 10.1080/14767058.2017.1315662] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Mor Cucuy
- Department of Neonatology, Kaplan Medical Center, Rehovot, Israel
- Hebrew University, Jerusalem, Israel
| | - Ada Juster-Reicher
- Department of Neonatology, Kaplan Medical Center, Rehovot, Israel
- Hebrew University, Jerusalem, Israel
| | - Orna Flidel
- Department of Neonatology, Kaplan Medical Center, Rehovot, Israel
- Hebrew University, Jerusalem, Israel
| | - Eric Shinwell
- Department of Neonatology, Ziv Medical Center, Tsfat, Israel
- Faculty of Medicine in the Galil, Bar-Ilan Universit, Tsfat, Israel
| |
Collapse
|
11
|
Olusanya BO, Imosemi DO, Emokpae AA. Differences Between Transcutaneous and Serum Bilirubin Measurements in Black African Neonates. Pediatrics 2016; 138:peds.2016-0907. [PMID: 27577578 DOI: 10.1542/peds.2016-0907] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/30/2016] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND AND OBJECTIVE Transcutaneous bilirubin (TcB) correlates positively with total serum bilirubin (TSB) across different racial populations. However, little is known about the pattern of divergence between TcB and TSB at individual patient-level and the relationship with TcB measuring techniques among African neonates. This study, therefore, investigates TcB-TSB discrepancies and the contribution of 2 models of transcutaneous bilirubinometers to the observed divergence in a black African population. METHODS Medical records were retrieved for late preterm and term infants with 1 to 3 pairs of TcB and TSB measurements between December 2011 to June 2015 in Nigeria. Divergence between TcB and TSB values for each infant was determined and the associated factors explored with generalized estimating equations for logistic regression. Contributions of BiliChek and JM-103 transcutaneous bilirubinometers to the divergence were further explored through linear regression and Bland-Altman analysis. RESULTS Overall, 2107 TcB/TSB measurements from 1553 infants were analyzed. TSB was overestimated by ≥2 mg/dL in 64.5%, ≥3 mg/dL in 42.7%, and ≥4 mg/dL in 25.7% of all measurements. In contrast, TSB was underestimated by ≥2 mg/dL in 1.1%, ≥3 mg/dL in 0.5%, and ≥4 mg/dL in 0.3% of all recordings. Postnatal age, feeding mode, and type of TcB instrument were predictive of TSB overestimation. The JM-103 was associated with greater imprecision than BiliChek at all TSB levels. CONCLUSIONS BiliChek and JM-103 bilirubinometers significantly overestimate TSB in black African neonates and may result in unnecessary or excessive treatments. Additional development of appropriate bilirubin determination devices for this racial group, especially in resource-limited settings, is warranted.
Collapse
|
12
|
Danaei N, lotfpour S, Ghorbani R, Emadi A, Nooripour S. Evaluating the Diagnostic Value of Skin Bilirubin in Comparison with Plasma Bilirubin to Identify Hyperbilirubinemia in Healthy Babies. MIDDLE EAST JOURNAL OF REHABILITATION AND HEALTH 2016. [DOI: 10.17795/mejrh-33493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
13
|
Kurokawa D, Nakamura H, Yokota T, Iwatani S, Morisawa T, Katayama Y, Sakai H, Ioroi T, Iijima K, Morioka I. Screening for Hyperbilirubinemia in Japanese Very Low Birthweight Infants Using Transcutaneous Bilirubinometry. J Pediatr 2016; 168:77-81.e1. [PMID: 26410797 DOI: 10.1016/j.jpeds.2015.08.038] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Revised: 07/21/2015] [Accepted: 08/13/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To assess the accuracy of transcutaneous bilirubin (TcB) measurements at 5 different body sites in Japanese very low birthweight (VLBW) infants and to determine a cut-off value of TcB to detect total serum/plasma bilirubin (TB) levels ≥10 mg/dL (171 μM). STUDY DESIGN In a prospective multicenter study, 85 Japanese VLBW infants were enrolled from 5 neonatal intensive care units during the study period. A total of 383 blood samples from infants not receiving phototherapy or ≥24 hours postphototherapy were analyzed. TcB was measured at the forehead, sternum, upper back, lower abdomen, and waist within 1 hour of blood collection. Linear regression analysis and Bland-Altman plots were used to compare TcB values at each site with TB levels. The TcB cut-off value for detecting TB ≥10 mg/dL was determined by receiver operating characteristics curve analysis. RESULTS TcB significantly correlated with TB, but the coefficient of determination varied among the sites (forehead: 0.5294, sternum: 0.6488, upper back: 0.6321, lower abdomen: 0.5430, waist: 0.7396). At a TcB value ≥8, the sensitivity was 100% at the sternum and upper back, 85% at the waist, 84% at the forehead, and 64% at the lower abdomen to detect TB ≥10 mg/dL. CONCLUSIONS In Japanese VLBW infants, the accuracy of TcB measurements varies according to body site. TcB ≥8 on the sternum or upper back is more reliable than that on the forehead, lower abdomen, or waist to detect TB levels ≥10 mg/dL.
Collapse
Affiliation(s)
- Daisuke Kurokawa
- Department of Pediatrics, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Hajime Nakamura
- Department of Pediatrics, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Tomoyuki Yokota
- Department of Pediatrics, Kobe University Graduate School of Medicine, Kobe, Japan; Department of Pediatrics, Kakogawa West Municipal Hospital, Kakogawa, Japan
| | - Sota Iwatani
- Department of Pediatrics, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Takeshi Morisawa
- Department of Pediatrics, Kakogawa West Municipal Hospital, Kakogawa, Japan
| | | | - Hitomi Sakai
- Department of Neonatology, Hyogo Prefectural Kobe Children's Hospital, Kobe, Japan
| | - Tomoaki Ioroi
- Department of Pediatrics, Japanese Red Cross Society Himeji Hospital, Himeji, Japan
| | - Kazumoto Iijima
- Department of Pediatrics, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Ichiro Morioka
- Department of Pediatrics, Kobe University Graduate School of Medicine, Kobe, Japan.
| |
Collapse
|
14
|
Abstract
Although the modern era of transcutaneous bilirubin monitoring (TcB) began only about 35 years ago, this screening tool is now widely used in newborn nurseries and outpatient clinics, offices, and emergency departments to obtain a rapid and non-invasive estimate of the degree of hyperbilirubinemia. TcB devices have become more sophisticated, and major breakthroughs include the following: (a) ability to report a bilirubin value rather than an index value, (b) enhanced correction for chromophores other than bilirubin, and (c) technologic improvements including interface with electronic medical records. Good agreement with laboratory bilirubin measurement has been demonstrated, and the ability of TcB screening to predict and decrease the incidence of subsequent hyperbilirubinemia has been well-documented. To date, it has not been shown that this screening results in improved long-term outcomes.
Collapse
Affiliation(s)
- William D Engle
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-9063.
| | - Gregory L Jackson
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-9063
| | - Nancy G Engle
- College of Nursing, University of Texas Arlington, Arlington, TX
| |
Collapse
|
15
|
Interscapular site for transcutaneous bilirubin measurement in preterm infants: a better and safer screening site. J Perinatol 2014; 34:209-12. [PMID: 24406742 DOI: 10.1038/jp.2013.167] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2013] [Revised: 10/26/2013] [Accepted: 11/20/2013] [Indexed: 11/08/2022]
Abstract
OBJECTIVE To prevent bilirubin induced brain injury in the newborn, repeated blood withdrawals are necessary to ascertain bilirubin levels and institute care. Noninvasive, painless and bloodless screening using transcutaneous bilirubinometry is the standard of care for term and near term neonates but there is still debate about its use with preterm neonates. The aims of this study were to determine how transcutaneous bilirubin (TcB) level measured from the interscapular site related to total serum bilirubin (TSB) level and to compare performance of TcB from the forehead, sternum and interscapular sites in identifying preterm neonates in need of phototherapy. STUDY DESIGN This was a cross sectional study conducted at Groote Schuur level III neonatal unit. Over a 5-month period 122 consecutive preterm neonates <35 weeks gestational age were enrolled. TcBs were measured over the forehead, sternum and interscapular area. Pearson's correlation coefficients and differences between TSB and TcBs were computed. P-value <0.05 was considered significant. RESULT The median gestational age of the study participants was 31 weeks (range: 24 to 34 weeks), the median TSB level was 81.5 μmol l(-1) (range: 25 to 229 μmol l(-1)) and 45% had a TSB at the phototherapy threshold. The correlation coefficients for TcBs ranged from 0.859 to 0.929 (P<0.001). The difference between TSB and TcBs ranged from -86 to +51 μmol l(-1). With respect to initiating phototherapy, the interscapular site had the highest sensitivity of 94% and lowest false negative rate of 6%. CONCLUSION Using transcutaneous bilirubinometry, the interscapular site is superior and safer for screening preterm neonates.
Collapse
|
16
|
Accuracy and precision of transcutaneous bilirubinometry in postdischarge Asian neonates. Eur J Pediatr 2013; 172:781-6. [PMID: 23397326 DOI: 10.1007/s00431-013-1960-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2012] [Accepted: 01/22/2013] [Indexed: 11/27/2022]
Abstract
UNLABELLED A prospective cross-sectional study was conducted in a tertiary care center to determine the accuracy of transcutaneous bilirubin measurements (TcB) measured by the Konica Minolta JM-103™ meter compared to total serum bilirubin (TSB) in Asian infants aged 5-14 days. There were 405 late-preterm and term infants involved, and 455 paired samples were obtained by venepuncture and analyzed for bilirubin levels. TcB measurements were performed using the average of three measurements (TcB3) and a single measurement (TcB1) method. The overall correlation between TSB and the TcB was 0.80 (p ≤ 0.001) for TcB3 and 0.76 (p ≤ 0.001) for TcB1, respectively. The mean (SD) difference between TcB3 and TSB was -17.6 (29.5) μmol/L (median, -17.0; interquartile range (IQR), -39.1 to 1.7) and between TcB1 and TSB was -20.7 (32.3) μmol/L (median, -20.4; IQR, -42.5 to 1.7). The mean difference (SD) between the TcB3 and TSB in the low-risk (TSB < 170 μmol/L), intermediate-risk (TSB 170-254 μmol/L), and high-risk (TSB ≥ 255 μmol/L) groups was -2.8 (27.2), -13.4 (27.0), and -33.4 (29.1) μmol/L, respectively. To detect a TSB level of ≥255 μmol/L, using the TcB cutoff level of 204 μmol/L provides a sensitivity of 96 % with a specificity of 58 %. CONCLUSION The TcB meter using a specific cutoff level can be reliably used as a screening tool for jaundice detection in older, postdischarge neonates, including the Asian population. Lower cutoff values can be set to capture all infants who merit closer surveillance, potential investigation, and treatment with higher accompanying screening costs.
Collapse
|
17
|
Coda Zabetta CD, Iskander IF, Greco C, Bellarosa C, Demarini S, Tiribelli C, Wennberg RP. Bilistick: a low-cost point-of-care system to measure total plasma bilirubin. Neonatology 2013; 103:177-81. [PMID: 23295342 DOI: 10.1159/000345425] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2012] [Accepted: 10/25/2012] [Indexed: 11/19/2022]
Abstract
BACKGROUND Severe neonatal hyperbilirubinemia, with consequent encephalopathy, remains a common cause of morbidity and death in many regions of the world. Poor access to clinical laboratory resources and screening programs to measure plasma bilirubin levels is a major contributor to delayed treatment in developing countries, and the cost of existing point-of-care screening instruments precludes their dissemination. OBJECTIVES We are evaluating the accuracy of a low-cost, minimally invasive point-of-care system (Bilistick) requiring a 25-µl blood sample that could be used in low-resource environments to evaluate patients with neonatal jaundice. METHODS We compared plasma bilirubin levels in divided blood samples by clinical laboratories and by Bilistick at two medical centers serving term and near-term newborns from ethnically different populations. RESULTS 118 neonates with bilirubin levels ranging from 24.8 to 501.0 µmol/l were analyzed. The mean bilirubin concentration (±SD) was 215.6 ± 85.5 µmol/l for Bilistick and 226.1 ± 86.4 µmol/l by laboratory determination. Pearson's correlation coefficient between all paired results was 0.961, and the Bland-Altman analysis showed a mean difference of 10.3 µmol/l with a 95% interval of agreement of -38.0 to 58.7 µmol/l. CONCLUSION Bilistick is a minimally invasive method for measuring total bilirubin concentration over a wide range of values and should provide an affordable and accurate system for pre-discharge and follow-up screening of jaundiced infants, particularly in low-resource environments.
Collapse
Affiliation(s)
- C D Coda Zabetta
- Liver Research Centre, Italian Liver Foundation, Trieste, Italy.
| | | | | | | | | | | | | |
Collapse
|