1
|
Raza MA, Khan JA, Akhtar H, Farooqui WA, Faraz H, Hasan A. Comparison of two composite resin materials for splinting of dental luxation injuries: A double blind randomized controlled trial. Dent Traumatol 2024; 40:44-53. [PMID: 37615239 DOI: 10.1111/edt.12883] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 07/11/2023] [Accepted: 08/09/2023] [Indexed: 08/25/2023]
Abstract
BACKGROUND/AIM Luxation is a common traumatic dental injury treated with a wire composite (WC) splint. However, bulk-fill flowable composite and conventional packable composite have not been compared for retaining these splints. Therefore, the objectives of this randomized controlled trial were (1) to compare retention of WC splints, and (2) to compare adhesive point dimension, application and removal time, and effect on tooth mobility between the two WC splints. MATERIALS AND METHODS In this parallel group, non-inferiority double blind randomized controlled trial, a total of 90 patients, aged 16-50 years participated. They were randomly allocated into two groups, the packable composite group (PC) n = 45 and the bulk-fill flowable composite group (BF-FC) n = 45 by lottery method. Following measurements were taken at the splint application appointment. Horizontal tooth mobility measured via Periotest, splint application time, and frontal images of splinted teeth to measure the percentage composite adhesive point area. After 2 weeks, splints were visually inspected for retention, whereas mobility and removal times were also recorded. Statistically, comparisons were made using independent samples sample T-test, Fisher's exact test, and Mann-Whitney U at p ≤ .05. RESULTS A total of 88 patients with 156 luxated teeth completed the trial, as two patients were lost to follow-up. Two patients in the PC group reported with completely de-bonded splints while none de-bonded in the BF-FC group. Both groups were similar in terms of splint retention (p = .352), reduction of mobility (p = .426), and splint removal times (p = .372). The BF-FC group performed significantly better in adhesive point dimension percentages (p < .001) and splint application time (p < .001). CONCLUSION Both groups were comparable in most parameters of the study. However, for BF-FC group application time and adhesive point dimension were significantly less.
Collapse
Affiliation(s)
- Misbah Ali Raza
- Department of Operative Dentistry, Dow Dental College, Dow University of Health Sciences Baba-e-Urdu Road Karachi, Karachi, Pakistan
| | - Javeria Ali Khan
- Department of Operative Dentistry, Dow Dental College, Dow University of Health Sciences Baba-e-Urdu Road Karachi, Karachi, Pakistan
| | - Hira Akhtar
- Department of Operative Dentistry, Dow Dental College, Dow University of Health Sciences Baba-e-Urdu Road Karachi, Karachi, Pakistan
| | | | - Hira Faraz
- Department of Operative Dentistry, Dow Dental College, Dow University of Health Sciences Baba-e-Urdu Road Karachi, Karachi, Pakistan
| | - Arshad Hasan
- Department of Operative Dentistry, Dow Dental College, Dow University of Health Sciences Baba-e-Urdu Road Karachi, Karachi, Pakistan
| |
Collapse
|
2
|
Cavalcanti KGBA, Pulido C, Moreira PHA, Monteles CF, Salvatierra BLC, Siqueira FSF, Soares CJ, Reis A, Loguercio AD, Cardenas AFM. Effect of irradiance and exposure time on the adhesive properties of universal adhesives after 2 years of storage. Clin Oral Investig 2023; 27:5223-5232. [PMID: 37458867 DOI: 10.1007/s00784-023-05142-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 07/04/2023] [Indexed: 09/10/2023]
Abstract
OBJECTIVE This study aims to evaluate the effects of exposure time and irradiance on the dentin bonding properties (microtensile bond strength (μTBS) and nanoleakage (NL)) of the Clearfil Universal Bond Quick (CUQ) adhesive and Scotchbond Universal Adhesive (SBU) immediately and after 2 years of water storage. MATERIAL AND METHODS Hence, 128 human molars were randomly assigned to 16 groups based on adhesive strategy, irradiance/exposure times, and storage time for each universal adhesive tested. The adhesives were applied using the etch-and-rinse and self-etch strategies and were light-cured using four different irradiance/exposure times: 1400 mW/cm2 for 5 s (1400 × 5), 1400 mW/cm2 for 10 s (1400 × 10), 3200 mW/cm2 for 5 s (3200 × 5), and 3200 mW/cm2 for 10 s (3200 × 10). Then, each sample was restored and sectioned into a resin-dentin bonded stick to be tested for μTBS and NL (immediately and after 2 years of water storage). The mean μTBS and NL of all resin-dentin bonded sticks from the same hemi-tooth (factor time) were statistically analyzed using a three-way ANOVA and Tukey's test (a = 0.05). RESULTS Despite a significant decrease in the μTBS values for all groups after 2 years of water storage, the 3200 × 5 group showed higher μTBS values, whereas the 3200 × 10 group showed lower μTBS values for both universal adhesives tested. Although a significant increase in the NL values was observed for all groups after 2 years of water storage, the 3200 × 10 group showed higher NL values than the other groups (p < 0.001). CONCLUSION Results indicate that light-curing the adhesive layer with 14-16 J/cm2 led to an improvement in the stability of the resin-dentin adhesive interface. A longer exposure time (10 s) coupled with a higher irradiance (3200 mW/cm2) resulted in a greater degree of degradation of the adhesive interface. CLINICAL SIGNIFICANCE To guarantee better stability of the adhesive interface, clinicians could be preferred a light-cured universal adhesive layer with 14-16 J/cm2. Higher irradiances should be avoided.
Collapse
Affiliation(s)
| | - Camilo Pulido
- Department of Restorative Dentistry and Biomaterials, San Francisco de Quito University, Quito, Ecuador
| | - Pedro H A Moreira
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Camila F Monteles
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Byron L C Salvatierra
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil
| | | | - Carlos J Soares
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
- Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil.
| | | |
Collapse
|
3
|
Attia AM, Abo-Elezz AF, Safy RK. Effect of phytic acid on bond strength and interfacial integrity of universal adhesive to deep dentin. Braz Dent J 2022; 33:116-125. [DOI: 10.1590/0103-6440202204810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 07/13/2022] [Indexed: 11/07/2022] Open
Abstract
Abstract This study investigated the effect of phytic acid (IP6) in different concentrations and application times on microtensile bond strength (µTBS) and interfacial integrity of universal adhesive to deep dentin. Flat deep dentin surfaces of 48 human molars were either etched with 37% phosphoric acid (PA) for 15 sec (control); or received no acid treatment and universal adhesive was applied directly in a self-etch mode (SE); or divided according to IP6 concentration (C) into two main groups: C1, 0.5%, and C2, 1%. Specimens of IP6 groups were further subdivided into three subgroups according to application time of IP6 (T) where; T1, 15 sec; T2, 30 sec and T3, 60 sec. Single Bond Universal Adhesive was then applied and resin composite blocks were built-up. Forty Specimens were then sectioned to produce resin/dentin beams that were used for µTBS testing using a universal testing machine. The remaining eight specimens were sectioned into slabs that were immersed into ammonical silver nitrate solution and nanoleakage was observed using a field emission scanning electron microscope (FE-SEM). The results showed that the application of IP6 in 0.5% and 1% produced significantly higher µTBS and less nanoleakage compared to PA and SE groups. Also, the application of IP6 for 60 sec recorded the highest µTBS and the lowest nanoleakage followed by 30 sec, and 15 sec respectively. Therefore, conditioning of deep dentin with IP6 enhances µTBS and interfacial integrity of universal adhesive to deep dentin in comparison to PA etching or using the universal adhesive in SE mode.
Collapse
|
4
|
Cardenas A, Siqueira F, Nuñez A, Nonato RF, Cavalcanti K, Soares CJ, Reis A, Loguercio AD. Influence of Irradiance and Exposure Times on the Mechanical and Adhesive Properties of Universal Adhesives with Dentin. Oper Dent 2022; 47:412-424. [PMID: 35917253 DOI: 10.2341/21-042-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/10/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study evaluated the influence of irradiance/exposure time on the Knoop hardness (KHN) and polymer cross-linking density (PCLD), as well as microtensile bond strength (μTBS), nanoleakage (NL), and in situ degree of conversion (DC) of universal adhesives. METHODS AND MATERIALS Two universal adhesive systems, Clearfil Universal Bond Quick (CUQ) and Scotchbond Universal Adhesive (SBU), were light-cured using various irradiance/exposure times: 1400 mW/cm2 for 5 s (1400*5); 1400 mW/cm2 for 10 s (1400*10); 3200 mW/cm2 for 5 s (3200*5); and 3200 mW/cm2 for 10 s (3200*10). Adhesive disks from each group were used to measure PCLD by KHN. One hundred and twenty-eight human molars were randomly assigned to 16 groups according to the following variables: adhesive system vs adhesive strategies vs radiance/exposure times. After restoration, specimens were sectioned into resin-dentin sticks and tested for μTBS, NL, and DC. The data from PCLD (%), KHN, μTBS (MPa), NL (%), and DC (%) data were subjected to ANOVA and Tukey's test (α=0.05). RESULTS Significant reductions in KHN, μTBS, and DC (p=0.00001) values and an increase in NL and PCLD (p=0.00001) values were observed for 3200*10 when compared with other groups. Higher KHN, μTBS, and DC (p=0.000001) values were observed for 3200*5 in comparison with the other groups. The 1400*5 (7 J/cm2) and 1400*10 (14 J/cm2) groups showed intermediate values (p=0.000001). CONCLUSION Although similar results in terms of hardness, polymer cross-linking density and nanoleakage were observed when 5 seconds at 3200 mW/cm2 and 10 seconds at 1400 mW/cm2 groups were compared, the use of higher irradiance (3200 mW/cm2) for only 5 seconds showed better results in terms of bond strength and degree of conversion for both universal adhesives to dentin. The prolonged exposure time (10 seconds) at the higher irradiance (3200 mW/cm2) showed the worst results.
Collapse
Affiliation(s)
- Afm Cardenas
- Andres Felipe Millan Cardenas, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Fsf Siqueira
- Fabiana Suelen Figuerêdo de Siqueira, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - A Nuñez
- Alejandra Nuñez, DDS, Ms, PhD student, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, Paraná, Brazil, and Professor, Department of Restorative Dentistry and Biomaterials, San Francisco de Quito University, Quito, Ecuador
| | - R F Nonato
- Rammon de Faria Nonato, DDS, Ms student, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Kgba Cavalcanti
- Karoline Guará Brusaca Almeida Cavalcanti, DDS, Ms, PhD student, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - C J Soares
- Carlos José Soares, DDS, Ms, PhD, professor, Departament of Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil, and Dental School, Department of Operative Dentistry and Dental Materials, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - A Reis
- *Alessandra Reis, DDS, PhD, professor, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - A D Loguercio
- Alessandro D. Loguercio, DDS, Ms, PhD, professor, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| |
Collapse
|
5
|
de Brito GMAP, Silva DO, Macedo RFC, Ferreira MWC, Bauer J, Pedroso FDB, Reis A, Siqueira FSF, Loguercio AD, Cardenas AFM. Does the Application of Additional Hydrophobic Resin to Universal Adhesives Increase Bonding Longevity of Eroded Dentin? Polymers (Basel) 2022; 14:polym14132701. [PMID: 35808746 PMCID: PMC9268900 DOI: 10.3390/polym14132701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 05/17/2022] [Accepted: 05/30/2022] [Indexed: 12/10/2022] Open
Abstract
This paper evaluates the effect of an additional hydrophobic resin coat (extra HL) associated with universal adhesives on sound and eroded dentin and evaluated immediately or after 2 years of water storage to improve the microtensile bond strength (μTBS) and nanoleakage (NL) when compared to the use of universal adhesives only. Sixty-four molars were assigned to eight groups using the following combinations: 1. dentin substrate, including sound and eroded dentin; 2. treatment, including the control and extra HL and storage time (immediately and after two-years of storage). Two universal adhesives (Prime & Bond Active or Scotchbond Universal) were evaluated. Before restoration, half of the teeth were subjected to soft-drink erosion. Composite buildups were bonded; specimens were stored (37 °C/24 h), sectioned into resin−dentin bonded sticks and tested for microtensile bond strength and nanoleakage using SEM (immediately and after two-years of storage). Three-way ANOVA and Tukey’s test (α = 0.05%) were used. In the immediate testing, the application of extra HL did not increase microtensile bond strength values compared with the control group in either substrate (p > 0.05). However, extra HL significantly decreased nanoleakage values when applied to eroded and sound dentin (p = 0.0001). After two years, the application of extra HL produced significantly higher microtensile bond strength and lower nanoleakage values than the control group for both adhesives (p = 0.0001). In all cases, sound dentin showed higher microtensile bond strength and lower nanoleakage values than eroded dentin (p = 0.000001). An extra HL increased the bond strength and reduced nanoleakage in eroded dentin after two-years of storage.
Collapse
Affiliation(s)
- Graça Maria Abreu Pereira de Brito
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis 65075-120, Brazil; (G.M.A.P.d.B.); (D.O.S.); (F.S.F.S.); (A.F.M.C.)
| | - Daniella Oliveira Silva
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis 65075-120, Brazil; (G.M.A.P.d.B.); (D.O.S.); (F.S.F.S.); (A.F.M.C.)
| | | | | | - Jose Bauer
- Department of Postgraduate Program in Dentistry, Federal University of Maranhao, São Luis 65085-805, Brazil; (R.F.C.M.); (J.B.)
| | - Flavia de Brito Pedroso
- Department of Pharmacology, State University of Ponta Grossa, Uvaranas 84030-900, Brazil; (M.W.C.F.); (F.d.B.P.)
| | - Alessandra Reis
- Department of Restorative Dentistry, State University of Ponta Grossa, Uvaranas 84030-900, Brazil;
| | - Fabiana Suelen Figuerêdo Siqueira
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis 65075-120, Brazil; (G.M.A.P.d.B.); (D.O.S.); (F.S.F.S.); (A.F.M.C.)
| | - Alessandro Dourado Loguercio
- Department of Restorative Dentistry, State University of Ponta Grossa, Uvaranas 84030-900, Brazil;
- Correspondence:
| | - Andres Felipe Millan Cardenas
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis 65075-120, Brazil; (G.M.A.P.d.B.); (D.O.S.); (F.S.F.S.); (A.F.M.C.)
| |
Collapse
|
6
|
Stability and remineralization of proteoglycan-infused dentin substrate. Dent Mater 2021; 37:1724-1733. [PMID: 34538503 DOI: 10.1016/j.dental.2021.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 07/09/2021] [Accepted: 09/03/2021] [Indexed: 11/22/2022]
Abstract
OBJECTIVE This study tested the effects of small leucine-rich proteoglycan (SLRP) proteins on phosphoric acid (PA)-treated dentin bonding overtime and the role of such SLRPs in the remineralization potential of demineralized dentin collagen. METHODS Coronal dentin sections of human molars were used. SLRPs were either decorin (DCN) or biglycan (BGN) in core or proteoglycan form (with glycosaminoglycans, GAGs). Groups were: No treatment (control), DCN core, DCN + GAGs, BGN core, BGN + GAGs. Samples were etched with PA for 15 s and prior to application of Adper Single Bond Plus and composite buildup an aliquot of the specific SLRPs was applied over dentin. Twenty-four hours or 6 months after the bonding procedure, samples were tested for microtensile bond strength (MTBS). Debonded beams were analyzed by scanning electron microscopy (SEM). For remineralization studies, dentin blocks were fully demineralized, infused with the SLRPs, placed in artificial saliva for 2 weeks, and evaluated by transmission electron microscopy (TEM). RESULTS MTBS test presented a mean of 51.4 ± 9.1 MPa in control with no statistically significant difference to DCN core (47.6 ± 8.3) and BGN core (48.3 ± 6.5). The full proteoglycan groups DCN + GAGs (27.4 ± 4.5) and BGN + GAGs (36.4 ± 13.6) showed decreased MTBS compared to control (p < 0.001). At 6 months, control or core-treated samples did not have a statistically significant difference in MTBS. However, SLRPs with GAGs showed statistically significant improvement of bonding (62.5 ± 6.0 for DCN and 52.8 ± 8.1 for BGN, p < 0.001) compared to their baseline values. SEM showed that GAGs seem to favor water retention but overtime help remineralization. TEM of demineralized dentin indicated a larger collagen fibril diameter pattern of samples treated with core proteins compared to control and a smaller diameter with DCN + GAGs in water with evidence of mineralization with DCN + GAGS, BGN core and BGN + GAGs. SIGNIFICANCE In conclusion, core proteins seem not to affect dentin adhesion significantly but the presence of GAGs can be detrimental to immediate bonding. However, after ageing of samples, full proteoglycans, particularly DCN, can significantly improve bonding overtime while promoting remineralization which can prove to be clinically beneficial.
Collapse
|
7
|
Wang J, Song W, Zhu L, Wei X. A comparative study of the microtensile bond strength and microstructural differences between sclerotic and Normal dentine after surface pretreatment. BMC Oral Health 2019; 19:216. [PMID: 31590650 PMCID: PMC6781378 DOI: 10.1186/s12903-019-0899-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2018] [Accepted: 08/21/2019] [Indexed: 12/05/2022] Open
Abstract
Background The resin bond strength of sclerotic dentine is significantly lower than that of the normal dentine, which paused a challenge for bonding procedures clinically. The aim of this study was to compare the effects of different surface pretreatments on the micro-tensile bond strength and microstructure between sclerotic dentine and normal dentine. Methods Eighty teeth that were collected, forty premolars with typical wedge-shaped defects visually graded as class III were assigned as the sclerotic dentine group (SD), the other forty normal premolars with artificial wedge-shaped defects were assigned as the normal dentine group (ND). Each group was randomly subdivided into eight subgroups according to the solution used: 35% phosphoric acid, 15% EDTA, 5% or 10% NaClO. Then the dentine surface was examined using a scanning electron microscope (SEM). The lesions were restored using self-etching adhesive and the subsequent resin composite. The teeth were sectioned into sticks for the micro-tensile bond strength analysis, and the data were analysed using the SPSS17.0 software package (α = 0.05). Results First, for the ND groups, after pretreatment using 35% phosphoric acid, and 35% phosphoric acid + 5% or 10% sodium hypochlorite, the bonding strengths of the normal dentine were higher than that of the other groups (P < 0.05). Second, for the SD groups, after pretreatment using 35% phosphoric acid, 15% EDTA, and 35% phosphoric acid + 5% or 10% sodium hypochlorite, the bonding strengths of the sclerotic dentine were higher than that of the other groups (P < 0.05). Third, the bond strengths of the sclerotic dentine were lower than that of the normal dentine without any pretreatment (P < 0.05). After pretreatment using 35% phosphoric acid + 5% or 10% sodium hypochlorite, the bonding strengths of the sclerotic dentine were higher than that of the normal dentine (P < 0.05). SEM observation showed that the appearances of dentine surface were changed after pretreatment using the above solutions, with the reduced smear layer, opened small groove and increased dentinal tubules. Conclusion Pretreatment of dentine using 35% phosphoric acid+ 5% or + 10% sodium hypochlorite changed the microstructure of the sclerotic dentine surface and subsequently increased the micro-tensile bond strength.
Collapse
Affiliation(s)
- Jinhua Wang
- Jiangsu key Laboratory of Oral Diseases, Department of Conservative Dentistry and Endodontics, Stomatological Hospital, Nanjing Medical University, Nanjing, China.,The Affiliated Suzhou Science and Technology Town Hospital of Nanjing Medical University, Suzhou, China
| | - Weijian Song
- Jiangsu key Laboratory of Oral Diseases, Department of Conservative Dentistry and Endodontics, Stomatological Hospital, Nanjing Medical University, Nanjing, China.,The Affiliated Suzhou Science and Technology Town Hospital of Nanjing Medical University, Suzhou, China
| | - Lei Zhu
- Jiangsu key Laboratory of Oral Diseases, Department of Conservative Dentistry and Endodontics, Stomatological Hospital, Nanjing Medical University, Nanjing, China.,The Affiliated Suzhou Science and Technology Town Hospital of Nanjing Medical University, Suzhou, China
| | - Xin Wei
- Jiangsu key Laboratory of Oral Diseases, Department of Conservative Dentistry and Endodontics, Stomatological Hospital, Nanjing Medical University, Nanjing, China.
| |
Collapse
|
8
|
Improving bonding to eroded dentin by using collagen cross-linking agents: 2 years of water storage. Clin Oral Investig 2019; 24:809-822. [DOI: 10.1007/s00784-019-02918-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 04/29/2019] [Indexed: 12/11/2022]
|
9
|
Arpa C, Ceballos L, Fuentes MV, Perdigão J. Repair bond strength and nanoleakage of artificially aged CAD-CAM composite resin. J Prosthet Dent 2019; 121:523-530. [DOI: 10.1016/j.prosdent.2018.05.013] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 05/17/2018] [Accepted: 05/17/2018] [Indexed: 11/26/2022]
|
10
|
Farid F, Rostami K, Habibzadeh S, Kharazifard M. Effect of cement type and thickness on push-out bond strength of fiber posts. J Dent Res Dent Clin Dent Prospects 2019; 12:277-282. [PMID: 30774794 PMCID: PMC6368945 DOI: 10.15171/joddd.2018.043] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Accepted: 11/10/2018] [Indexed: 11/09/2022] Open
Abstract
Background. This study investigated the effect of the thickness of two resin cements on push-out bond strength of fiber posts to root dentin.
Methods. Sixty decoronated single-rooted teeth were endodontically treated. The specimens were then randomly allocated to two groups (n=30); group 1: drill size 90 w, matching the size of fiber posts used; group 2: drill size 110, larger than the posts. The specimens in each group were divided into 2 subgroups (n=15); subgroup SE, in which the posts were cemented with self-etch Panavia F2.0 and subgroup SA, in which self-adhesive Panavia cement was used. After 72 hours, 2 slices with 1 mm of thickness were prepared from the mid-root of each specimen. Push-out bond strength test was performed in a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with two-way ANOVA and t-test.
Results. The mean bond strengths of the posts cemented in matched-size spaces for SE and SA groups were 4.02±1.6 and 4.12±2.3 MPa, respectively. For posts cemented in oversized spaces, the values were 4.9±2.3 and 2.8±1.3 MPa, respectively. In matched-size spaces, there was no significant difference between the two groups.
Conclusion. The results of this study suggested that increasing the cement thickness would reduce the bond strength of fiber posts to root dentin when self-adhesive cements are used; however, self-etch adhesives were not affected.
Collapse
Affiliation(s)
- Farzaneh Farid
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Khadijeh Rostami
- DDS, School of Dentistry, International Branch, Tehran University of Medical Sciences, Tehran, Iran
| | - Sareh Habibzadeh
- Department of Prosthodontics, School of Dentistry, International Branch, Tehran University of Medical Sciences, Tehran, Iran
| | | |
Collapse
|
11
|
Cardenas A, Siqueira F, Bandeca M, Costa S, Lemos M, Feitora V, Reis A, Loguercio A, Gomes J. Impact of pH and application time of meta-phosphoric acid on resin-enamel and resin-dentin bonding. J Mech Behav Biomed Mater 2018; 78:352-361. [DOI: 10.1016/j.jmbbm.2017.11.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 11/15/2017] [Accepted: 11/17/2017] [Indexed: 10/18/2022]
|
12
|
Siqueira FSF, Cardenas AFM, Gomes GM, Chibinski AC, Gomes OMM, Bandeca MC, Loguercio AD, Gomes JC. Three-Year Effects of Deproteinization on the In Vitro Durability of Resin/Dentin-Eroded Interfaces. Oper Dent 2018; 43:60-70. [DOI: 10.2341/16-308-l] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
To evaluate the effect of sodium hypochlorite on the immediate and three-year bonding properties of a resin-eroded dentin interface produced by one of two adhesive strategies.
Methods and Materials:
Forty-eight molars were randomly assigned to six experimental groups, according to the combination of the adhesive strategy (etch-and-rinse and self-etch) and the dentin surface (control groups without erosion, eroded dentin surface [ED], and eroded dentin surface + NaOCl 5.2% [ED + NaOCl]). After completing restoration, specimens were stored in water (37°C) for 24 hours and then sectioned into resin–dentin beams (0.8 mm2) to be tested under tension (0.5 mm/min) immediately thereafter or after three years of water storage. To assess nanoleakage (NL), specimens were immersed in silver nitrate solution and examined by scanning electron microscopy at both time points. The dentin-etching pattern was examined under a scanning electron microscope. Data were subjected to appropriate statistical analysis (α=0.05)
Results:
In both strategies, a more pronounced and significant reduction of the microtensile bond strength (μTBS) values was observed for the ED groups (p=0.0001) after three years. However, in the ED + NaOCl group, μTBS values were maintained after three years of water storage. Furthermore, application of NaOCl to eroded dentin significantly reduced the immediate NL values and also preserved these values after three years of water storage for both adhesive strategies (p>0.05). When considering the ED group, a superficial removal of the smear layer and enlarged lumen tubules in comparison to control were present. However, for ED + NaOCl, there was a total removal of the smear layer and significant numbers of collagen fibrils were exposed.
Conclusion:
The use of NaOCl may maintain the long-term stability of a resin-eroded dentin interface formed by etch-and-rinse and self-etch adhesives.
Collapse
Affiliation(s)
- FSF Siqueira
- Fabiana Suelen Figueredo de Siqueira, DDS, MS, PhD student, Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, Brazil
| | - AFM Cardenas
- Andres Felipe Millan Cardenas, DDS, MS, PhD, professor, Department of Postgraduate Program in Dentistry, CEUMA University, São Luis, Brazil
| | - GM Gomes
- Giovana Mongruel Gomes, DDS, MS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, Brazil
| | - AC Chibinski
- Ana Claúdia Rodriguez Chibinski, DDS, MS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, Brazil
| | - OMM Gomes
- Giovana Mongruel Gomes, DDS, MS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, Brazil
| | - MC Bandeca
- Matheus Coelho Bandeca, DDS, MS, PhD, professor, Department of Postgraduate Program in Dentistry, CEUMA University, São Luis, Brazil
| | - AD Loguercio
- Alessandro D. Loguercio, DDS, MS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, Brazil
| | - JC Gomes
- Giovana Mongruel Gomes, DDS, MS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, Brazil
| |
Collapse
|
13
|
Martini EC, Parreiras SO, Gutierrez MF, Loguercio AD, Reis A. Effect of Different Protocols in Preconditioning With EDTA in Sclerotic Dentin and Enamel Before Universal Adhesives Applied in Self-etch Mode. Oper Dent 2017; 42:284-296. [DOI: 10.2341/16-014-l] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives:
The aim of this study was to investigate the effect of different protocols of 17% ethylene diamine tetra-acetic acid (EDTA) conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin.
Methods and Materials:
Forty bovine teeth with sclerotic dentin and 20 human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, two-minute EDTA conditioning manual application, 30-second EDTA manual application, 30-second EDTA sonic application) and adhesives systems (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bond specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests, respectively. The etching pattern produced on the unground enamel and the sclerotic dentin surfaces under the different protocols and adhesive systems was evaluated under scanning electron microscopy.
Results:
For enamel, only the main factor adhesive was significant (p<0.0001), with SBU showing the highest μSBS. In sclerotic dentin, the lowest mean was observed for the group without EDTA application and the highest mean in the group with EDTA application with the sonic device for 30 seconds. Regardless of the EDTA protocol, the highest means of μTBS were observed for SBU (p<0.05).
Conclusions:
EDTA conditioning improves the bonding performance of universal adhesives in the self-etch mode on sclerotic dentin, mainly when applied for 30 seconds with the aid of a sonic device. EDTA pretreatment also improves the retentive etching pattern of enamel, but it does not result in higher enamel bond strength.
Collapse
Affiliation(s)
- EC Martini
- Eveline Claudia Martini, DDS, graduate student, Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil
| | - SO Parreiras
- Sibelli Olivieri Parreiras, DDS, graduate student, Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil
| | - MF Gutierrez
- Mario Felipe Gutierrez, DDS, graduate student, Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil and professor, Institute for Research in Dental Sciences, Faculty of Dentistry, University of Chile, Santiago, Chile
| | - AD Loguercio
- Alessandro Dourado Loguercio, DDS, MS, PhD, associate professor, Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil
| | - A Reis
- Alessandra Reis, DDS, PhD, associate professor, Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil
| |
Collapse
|
14
|
Academy of Dental Materials guidance on in vitro testing of dental composite bonding effectiveness to dentin/enamel using micro-tensile bond strength (μTBS) approach. Dent Mater 2017; 33:133-143. [DOI: 10.1016/j.dental.2016.11.015] [Citation(s) in RCA: 193] [Impact Index Per Article: 27.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 11/29/2016] [Indexed: 11/24/2022]
|
15
|
Cross-linked dry bonding: A new etch-and-rinse technique. Dent Mater 2016; 32:1124-32. [PMID: 27431091 DOI: 10.1016/j.dental.2016.06.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2015] [Revised: 03/16/2016] [Accepted: 06/22/2016] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To determine if acid-etched, cross-linked dentin can be dehydrated without lowering bond strength below that of cross-linked wet-bonded dentin in vitro. METHODS Using extracted human third molars, control acid-etched dentin was bonded with Single Bond Plus, using either the wet- or dry-bonding technique. Experimental acid-etched dentin was treated with 5mass% grape seed extract (GSE) in different solvents for 1min before undergoing wet vs dry resin-dentin bonding with Single Bond Plus. Completely demineralized dentin beams were treated with 5% GSE for 0, 1 or 10min, before measuring stiffness by 3-point flexure. Other completely demineralized beams were treated similarly and then incubated in buffer for 1 week to measure the collagen solubilization by endogenous dentin proteases. RESULTS 24h microtensile bond strengths (μTBS) in wet and dry controls were 53.5±3.6 and 9.4±1.8MPa, respectively (p<0.05). 5% GSE in water gave μTBS of 53.7±3.4 and 39.1±9.7MPa (p<0.05), respectively, while 5% GSE in ethanol gave μTBS of 51.2±2.3 and 35.3±2.0MPa (p<0.05). 5% GSE in 5% EtOH/95% water gave wet and dry μTBS of 53.0±2.3 and 55.7±5.1MPa (p>0.05). Cross-linking demineralized dentin with 5% GSE increased stiffness of dentin and decreased collagen degradation (p<0.05). SIGNIFICANCE 5% GSE pretreatment of acid-etched dentin for 1min permits the dentin to be completely air-dried without lowering bond strength.
Collapse
|
16
|
Pimentel Corrêa AC, Cecchin D, de Almeida JFA, Gomes BPFDA, Zaia AA, Ferraz CCR. Sodium Thiosulfate for Recovery of Bond Strength to Dentin Treated with Sodium Hypochlorite. J Endod 2016; 42:284-8. [DOI: 10.1016/j.joen.2015.11.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Revised: 10/31/2015] [Accepted: 11/06/2015] [Indexed: 10/22/2022]
|
17
|
Tensile Bond Strengths of Two Adhesives on Irradiated and Nonirradiated Human Dentin. BIOMED RESEARCH INTERNATIONAL 2016; 2015:798972. [PMID: 26783528 PMCID: PMC4689887 DOI: 10.1155/2015/798972] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Accepted: 08/11/2015] [Indexed: 11/18/2022]
Abstract
The aim of this study was to assess the effect of radiotherapy on bond efficiency of two different adhesive systems using tensile bond strength test. Twenty extracted teeth after radiotherapy and twenty nonirradiated extracted teeth were used. The irradiation was applied in vivo to a minimal dose of 50 Gy. The specimens of each group were randomly assigned to two subgroups to test two different adhesive systems. A three-step/etch-and-rinse adhesive system (Optibond FL) and a two-steps/self-etch adhesive system (Optibond XTR) were used. Composite buildups were performed with a nanohybrid composite (Herculite XTR). All specimens were submitted to thermocycling ageing (10000 cycles). The specimens were sectioned in 1 mm(2) sticks. Microtensile bond strength tests were measured. Nonparametric statistical analyses were performed due to nonnormality of data. Optibond XTR on irradiated and nonirradiated teeth did not show any significant differences. However, Optibond FL bond strength was more effective on nonirradiated teeth than on irradiated teeth. Within the limitations of an in vitro study, it can be concluded that radiotherapy had a significant detrimental effect on bond strength to human dentin. However, it seems that adhesive choice could be adapted to the substrata. According to the present study, the two-steps/self-etch (Optibond XTR) adhesive system tested could be more effective on irradiated dentin compared to three-steps/etch-and-rinse adhesive system (Optibond FL).
Collapse
|
18
|
Bond strength of universal adhesives: A systematic review and meta-analysis. J Dent 2015; 43:765-76. [DOI: 10.1016/j.jdent.2015.04.003] [Citation(s) in RCA: 296] [Impact Index Per Article: 32.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 03/14/2015] [Accepted: 04/05/2015] [Indexed: 11/23/2022] Open
|
19
|
Yesilyurt C, Ayar MK, Yildirim T, Akdag MS. Effect of simplified ethanol-wet bonding on dentin bonding durability of etchand-rinse adhesives. Dent Mater J 2015; 34:441-8. [PMID: 25948146 DOI: 10.4012/dmj.2014-335] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This in vitro study evaluated the effects of simplified ethanol-wet bonding technique on dentin bonding durability of two etchand-rinse adhesives to bovine dentin. Sixteen freshly extracted bovine incisors were divided into four groups according to bonding technique (water-wet or ethanol-wet bonding) and adhesive (Single Bond 2 or Prime & Bond NT). After etching and rinsing, dentin surfaces were left either water-moist or immersed in ethanol. Following adhesive application and composite build-up, bonded teeth were sectioned into sticks for microtensile bond strength (µTBS) testing conducted after 24-h and 12-month water storage. There were no significant differences in bond strength among the groups at 24 h. At 12 months, the bond strengths of adhesives to dentin were significantly decreased (p<0.05). Simplified ethanol-wet bonding did not improve the resin-dentin bonding durability of tested etch-and-rinse adhesives.
Collapse
Affiliation(s)
- Cemal Yesilyurt
- Department of Restorative Dentistry, Faculty of Dentistry, Karadeniz Technical University
| | | | | | | |
Collapse
|
20
|
Muñoz MA, Luque-Martinez I, Malaquias P, Hass V, Reis A, Campanha NH, Loguercio AD. In vitro longevity of bonding properties of universal adhesives to dentin. Oper Dent 2015; 40:282-92. [PMID: 25405904 DOI: 10.2341/14-055-l] [Citation(s) in RCA: 111] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To evaluate the immediate and 6-month resin-dentin bond strength (μTBS) and nanoleakage (NL) of universal adhesives that contain or do not contain methacryloyloxydecyl dihydrogen phosphate (MDP) and are used in the etch-and-rinse and self-etch strategies. METHODS AND MATERIALS Forty caries-free extracted third molars were divided into eight groups for μTBS (n=5). The groups were bonded with the Clearfil SE Bond (CSE) and Adper Single Bond 2 (SB) as controls; Peak Universal, self-etch (PkSe) and etch-and rinse (PkEr); Scotchbond Universal Adhesive, self-etch (ScSe) and etch-and-rinse (ScEr); and All Bond Universal, self-etch (AlSe) and etch-and-rinse (AlEr). After composite restorations, specimens were longitudinally sectioned to obtain resin-dentin bonded sticks (0.8 mm(2)). The μTBS of the specimens was tested immediately (IM) or after 6 months of water storage (6M) at 0.5 mm/min. Some sticks at each storage period were immersed in silver nitrate and photo developed, and the NL was evaluated with scanning electron microscopy. Data were analyzed with two-way repeated-measures analysis of variance and Tukey test (α=0.05). RESULTS At the IM period, PkSe and PkEr showed μTBS similar to the control adhesives (p>0.05) but increased NL pattern and lower μTBS after 6M (p<0.05). ScSe and ScEr showed intermediary μTBS values at the IM period but remained stable after 6 months (p>0.05). AlSe showed the lowest μTBS (p<0.05), but μTBS and NL remained stable after 6M (p>0.05). AlEr showed higher IM μTBS but showed higher degradation after 6M (p<0.05). CONCLUSIONS Universal adhesives that contain MDP showed higher and more stable μTBS with reduced NL at the interfaces after 6 months of water storage.
Collapse
|
21
|
Profeta AC. Preparation and properties of calcium-silicate filled resins for dental restoration. Part II: Micro-mechanical behaviour to primed mineral-depleted dentine. Acta Odontol Scand 2014; 72:607-17. [PMID: 24490642 DOI: 10.3109/00016357.2014.880188] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE Evaluating microtensile bond strength (μTBS) and Knoop micro-hardness (KHN) of resin bonded-dentine interfaces created with two methacrylate-based systems either incorporating Bioglass 45S5 (3-E&RA/BG) or MTA (3-E&RA/WMTA). MATERIALS AND METHODS Solvated resins (50% ethanol/50% co-monomers) were used as primers while their neat counterparts were filled with the two calcium-silicate compounds. Application of neat resin adhesive with no filler served as control (3-E&RA). μTBS, KHN analysis and confocal tandem scanning microscopy (TSM) micropermeability were carried out after 24 h and 10 months of storage in phosphate buffer solution (DPBS). Scanning electron microscopy (SEM) was also performed after debonding. RESULTS High μTBS values were achieved in all groups after 24 h of DPBS storage. On the contrary, solely the specimens created using 3-E&RA/BG and 3-E&RA/WMTA agents showed no significant reduction in terms of μTBS even after 10 months in DPBS; similarly, they did not restore the average superficial micro-hardness to the level of sound dentine, but maintained unchanged KHN values, and no statistical decrease was found following 10 months of DPBS storage. The only statistically significant changes occurred in the resin-dentine interfaces bonded with 3-E&RA that were subjected to a reduction of both μTBS and KHN values with ageing. In terms of micropermeability, adverse results were obtained with 3-E&RA while 3-E&RA/BG and 3-E&RA/WMTA demonstrated a beneficial effect after prolonged DPBS storage. CONCLUSION Calcium-silicate filled composite resins performed better than a current etch-and-rinse adhesive and had a therapeutic/protective effect on the micro-mechanical properties of mineral-depleted resin-dentine interfaces. CLINICAL SIGNIFICANCE The incorporation of calcium-silicates into dental restorative and bonding agents can create more biomimetic (life-like) restorations. This will not only enable these materials to mimic the physical characteristics of the tooth structure, but will also stabilize and protect the remaining dental hard tissues.
Collapse
Affiliation(s)
- Andrea Corrado Profeta
- Department of Restorative Dentistry, Biomaterials Science, Biomimetics and Biophotonics (B3) Research Group, King's College London Dental Institute, Guy's Dental Hospital , London , UK
| |
Collapse
|
22
|
Castro MCC, Sadek FT, Batitucci E, Miranda MS. The effect of disk type and cutting speed on the micro-tensile bond strength of ceramic specimens to resin cement. Dent Mater J 2014; 33:770-7. [PMID: 25311334 DOI: 10.4012/dmj.2013-160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The bond strength of dental materials has been evaluated by tensile testing of micro-specimens. The cutting process used to obtain specimens may influence the results. The objective of this study was to investigate the influence of different types of diamond disks and cutting speeds on the bond strength of ceramic specimens and on specimen integrity. Lithium disilicate-based ceramic cubes were bonded with resin cement to composite resin cubes, according to the manufacturers' instructions. The ceramic/cement/resin blocks thus obtained were divided into two groups to be cut with Buehler(®) or Extec(®) disks and then sectioned at cutting speeds of 200 rpm and 400 rpm. The results showed that the bond strength values were affected by the cutting speed and disk/speed interaction (p<0.05). SEM analysis revealed better specimen properties when the blocks were cut at 200 rpm. It was concluded that ceramic specimens must be cut at low speeds.
Collapse
|
23
|
Sirisha K, Rambabu T, Ravishankar Y, Ravikumar P. Validity of bond strength tests: A critical review-Part II. J Conserv Dent 2014; 17:420-6. [PMID: 25298640 PMCID: PMC4174699 DOI: 10.4103/0972-0707.139823] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2014] [Revised: 05/20/2014] [Accepted: 06/04/2014] [Indexed: 11/21/2022] Open
Abstract
Background: Macro-bond strength tests resulted in cohesive failures and overestimation of bond strengths. To reduce the flaws, micro-bond strength tests were introduced. They are the most commonly used bond-strength tests. Objective: Thus the objective of this review is to critically review the reliability of micro-bond strength tests used to evaluate resin-tooth interface. Data Collection: Relevant articles published between January 1994 and July 2013 were collected from Pubmed database, Google scholar and hand searched journals of Conservative Dentistry, Endodontics and Dental materials. Data Synthesis: Variables that influence the test outcome are categorized into substrate related factors, factors related to specimen properties, specimen preparation and test methodology. Impact of these variables on the test outcome is critically analyzed. Conclusion: Micro-bond tests are more reliable than macro-bond tests. However, no standard format exists for reporting the bond strength tests which could lead to misinterpretation of the data and bonding abilities of adhesives.
Collapse
Affiliation(s)
- Kantheti Sirisha
- Departments of Conservative Dentistry and Endodontics, GITAM Dental College and Hospital, Visakhapatnam, Andhra Pradesh, India
| | - Tankonda Rambabu
- Departments of Conservative Dentistry and Endodontics, Vishnu Dental College and Hospital, Bhimavaram, Andhra Pradesh, India
| | - Yalavarthi Ravishankar
- Department of Prosthodontics, GITAM Dental College and Hospital, Visakhapatnam, Andhra Pradesh, India
| | - Pabbati Ravikumar
- Departments of Conservative Dentistry and Endodontics, SIBAR Institute of Dental Sciences, Guntur, Andhra Pradesh, India
| |
Collapse
|
24
|
Effects of solvent evaporation time on immediate adhesive properties of universal adhesives to dentin. Dent Mater 2014; 30:1126-35. [DOI: 10.1016/j.dental.2014.07.002] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 04/19/2014] [Accepted: 07/07/2014] [Indexed: 11/18/2022]
|
25
|
Bonding performance of universal adhesives in different etching modes. J Dent 2014; 42:800-7. [DOI: 10.1016/j.jdent.2014.04.012] [Citation(s) in RCA: 171] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Revised: 04/11/2014] [Accepted: 04/28/2014] [Indexed: 11/18/2022] Open
|
26
|
Muñoz MA, Sezinando A, Luque-Martinez I, Szesz AL, Reis A, Loguercio AD, Bombarda NH, Perdigão J. Influence of a hydrophobic resin coating on the bonding efficacy of three universal adhesives. J Dent 2014; 42:595-602. [DOI: 10.1016/j.jdent.2014.01.013] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2013] [Accepted: 01/28/2014] [Indexed: 11/29/2022] Open
|
27
|
Loguercio AD, Luque-Martinez I, Muñoz MA, Szesz AL, Cuadros-Sánchez J, Reis A. A comprehensive laboratory screening of three-step etch-and-rinse adhesives. Oper Dent 2014; 39:652-62. [PMID: 24720263 DOI: 10.2341/13-236] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study evaluated several bonding (microtensile bond strengths [μTBS], nanoleakage [NL], and in situ degree of conversion [ISDC] on dentin) and mechanical properties (ultimate tensile strength [UTS], degree of conversion [DC], water sorption [WS], and solubility [SL] in water) of four three-step etch-and-rinse adhesives in the short term. METHODS A total of 28 molars were used in this study. The dentin surfaces were bonded with the following adhesives: All-Bond 3 (ALB3); Fusion Duralink (FSDL); Optibond FL (OBFL), and Scotchbond Multi-Purpose (SBMP). After each adhesive-system application, composite resin build-ups were added. For bonding tests, specimens were sectioned in order to obtain bonded sticks. The sticks were divided to be tested for μTBS (0.5 mm/min), for NL (n=2), and ISDC (n=2). For NL, they were immersed in 50% silver nitrate and analyzed by scanning election microscopy. For ISDC, the hybrid layer was evaluated by micro-Raman spectroscopy. An hourglass-shaped matrix (UTS) or disk-shaped matrix (WS and SL) was filled with primer and adhesive (1:1 ratio) and light-polymerized. For UTS evaluation, the specimens were tested under tension. For WS and SL, specimens were desiccated and stored in distilled water to evaluate water diffusion kinetics over a 28-day period. The DC of the adhesives was evaluated by Fourier transformed infrared spectroscopy. The data from each test were analyzed by appropriate statistical methods. RESULTS OBFL resulted in the highest μTBS, lower NL, higher ISDC and DC, and higher UTS than other adhesives (p<0.05), as well as lower WS (similar to ALB3 and FSDL) and SL (similar to ALB3 and SBMP) (p>0.05). ALB3 showed a higher NL and the lowest DC value. FSDL showed the highest NL and SL and the lowest ISDC. SBMP showed the lowest pattern of WS (p<0.05)CONCLUSION: OBFL showed the best results in all the properties evaluated, and it can be considered the gold standard of the three-step etch-and-rinse adhesive systems.
Collapse
|
28
|
Radiotherapy does not impair dentin adhesive properties in head and neck cancer patients. Clin Oral Investig 2013; 18:1771-8. [DOI: 10.1007/s00784-013-1155-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Accepted: 11/24/2013] [Indexed: 10/25/2022]
|
29
|
Perdigão J, Muñoz MA, Sezinando A, Luque-Martinez IV, Staichak R, Reis A, Loguercio AD. Immediate adhesive properties to dentin and enamel of a universal adhesive associated with a hydrophobic resin coat. Oper Dent 2013; 39:489-99. [PMID: 24299446 DOI: 10.2341/13-203-lr] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To evaluate the effect of acid etching and application of a hydrophobic resin coat on the enamel/dentin bond strengths and degree of conversion (DC) within the hybrid layer of a universal adhesive system (G-Bond Plus [GB]). METHODS A total of 60 extracted third molars were divided into four groups for bond-strength testing, according to the adhesive strategy: GB applied as a one-step self-etch adhesive (1-stepSE); GB applied as in 1-stepSE followed by one coat of the hydrophobic resin Heliobond (2-stepSE); GB applied as a two-step etch-and-rinse adhesive (2-stepER); GB applied as in 2-stepER followed by one coat of the hydrophobic resin Heliobond (3-stepER). There were 40 teeth used for enamel microshear bond strength (μSBS) and DC; and 20 teeth used for dentin microtensile bond strength (μTBS) and DC. After restorations were constructed, specimens were stored in water (37°C/24 h) and then tested at 0.5 mm/min (μTBS) or 1.0 mm/min (μSBS). Enamel-resin and dentin-resin interfaces from each group were evaluated for DC using micro-Raman spectroscopy. Data were analyzed with two-way analysis of variance for each substrate and the Tukey test (α=0.05). RESULTS For enamel, the use of a hydrophobic resin coat resulted in statistically significant higher mean enamel μSBS only for the ER strategy (3-stepER vs 2-stepER, p<0.0002). DC was significantly improved for the SE strategy (p<0.00002). For dentin, the use of a hydrophobic resin coat resulted in significantly higher dentin mean μTBS only for the SE strategy (2-stepSE vs 1-stepSE, p<0.0007). DC was significantly improved in groups 2-stepSE and 3-stepER when compared with 1-stepSE and 2-stepER, respectively (p<0.0009). CONCLUSIONS The use of a hydrophobic resin coat may be beneficial for the selective enamel etching technique, because it improves bond strengths to enamel when applied with the ER strategy and to dentin when used with the SE adhesion strategy. The application of a hydrophobic resin coat may improve DC in resin-dentin interfaces formed with either the SE or the ER strategy. On enamel, DC may benefit from the application of a hydrophobic resin coat over 1-stepSE adhesives.
Collapse
|
30
|
Shafiei F, Doozandeh M. Impact of oxalate desensitizer combined with ethylene-diamine tetra acetic acid-conditioning on dentin bond strength of one-bottle adhesives during dry bonding. J Conserv Dent 2013; 16:252-6. [PMID: 23833461 PMCID: PMC3698591 DOI: 10.4103/0972-0707.111327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2012] [Revised: 08/23/2012] [Accepted: 01/18/2013] [Indexed: 11/15/2022] Open
Abstract
Background: Elimination of water entrapment in hybrid layer during bonding procedure would increase bonding durability. Aims: This study evaluated the effect of oxalate desensitizer (OX) pretreatment on bond strength of three one-bottle adhesives to ethylene-diamine tetra acetic acid (EDTA)-conditioned dentin under dry bonding. Materials and Methods: Three adhesive systems, One-Step Plus (OS), Optibond Solo Plus (OP) and Adper Single Bond (SB) were bonded on dentin surfaces under four bonding conditions: (1) Wet-bonding on acid-etched dentin, (2) wet bonding on EDTA-conditioned dentin, (3) dry bonding on EDTA-conditioned dentin, (4) dry bonding associated with OX on the EDTA-conditioned dentin. After storage and thermo cycling, shear bond strength test was performed. Data were analyzed using two-way analysis of variance and Tukey tests. Results: Wet bonding with EDTA or acid etching showed similar bond strength for test adhesives. Dry bonding with EDTA significantly decreased the bond strength of OS, but it had no effect on the bonding of OP and SB. OX application in the forth bonding condition, in comparison with the third condition, had a negative effect on the bond strength of OP, but not influence on OS and SB. Conclusions: The use of an OX on EDTA-conditioned dentin compromised the bonding efficacy of OS and OP under dry bonding but compatible for SB.
Collapse
Affiliation(s)
- Fereshteh Shafiei
- Department of Operative Dentistry, Shiraz School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | | |
Collapse
|
31
|
Correlation between degree of conversion, resin-dentin bond strength and nanoleakage of simplified etch-and-rinse adhesives. Dent Mater 2013; 29:921-8. [PMID: 23830512 DOI: 10.1016/j.dental.2013.05.001] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2012] [Revised: 04/18/2013] [Accepted: 05/02/2013] [Indexed: 11/23/2022]
Abstract
OBJECTIVES The aim of this study was to correlate the degree of conversion measured inside the hybrid layer (DC) with the microtensile resin-dentin bond strength (μTBS) and silver nitrate uptake or nanoleakage (SNU) for five simplified etch-and-rinse adhesive systems. METHODS Fifty-five caries free extracted molars were used in this study. Thirty teeth were used for μTBS/SNU [n=6] and 25 teeth for DC [n=5]. The dentin surfaces were bonded with the following adhesives: Adper Single Bond 2 (SB), Ambar (AB), XP Bond (XP), Tetric N-Bond (TE) and Stae (ST) followed by composite resin build-ups. For μTBS and SNU test, bonded teeth were sectioned in order to obtain stick-shaped specimens (0.8mm(2)), which were tested under tensile stress (0.5mm/min). Three bonded sticks, from each tooth, were not tested in tensile stress and they were immersed in 50% silver nitrate, photo-developed and analyzed by scanning electron microscopy. Longitudinal 1-mm thick sections were prepared for the teeth assigned for DC measurement and evaluated by micro-Raman spectroscopy. RESULTS ST showed lowest DC, μTBS, and higher SNU (p<0.05). All other adhesives showed similar DC, μTBS, and SNU (p>0.05), except for TE which showed an intermediate SNU level. The DC was positively correlated with μTBS and negatively correlated with SNU (p<0.05). SNU was also negatively correlated with μTBS (p<0.05). SIGNIFICANCE The measurement of DC inside the hybrid layer can provide some information about bonding performance of adhesive systems since this property showed a good correlation with resin-dentin bond strength and SNU values.
Collapse
|
32
|
Stape THS, Menezes MDS, Barreto BDCF, Naves LZ, Aguiar FHB, Quagliatto PS, Martins LRM. Influence of chlorhexidine on dentin adhesive interface micromorphology and nanoleakage expression of resin cements. Microsc Res Tech 2013; 76:788-94. [PMID: 23737406 DOI: 10.1002/jemt.22230] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2013] [Revised: 04/09/2013] [Accepted: 04/23/2013] [Indexed: 11/10/2022]
Abstract
This study focused on adhesive interface morphologic characterization and nanoleakage expression of resin cements bonded to human dentin pretreated with 1% chlorhexidine (CHX). Thirty-two non-carious human third molars were ground flat to expose superficial dentin. Resin composite blocks were luted to the exposed dentin using one conventional (RelyX ARC) and one self-adhesive resin cement (RelyX U100), with/without CHX pretreatment. Four groups (n = 8) were obtained: control groups (ARC and U100); experimental groups (ARC/CHX and U100/CHX) were pretreated with 1% CHX prior to the luting process. After storage in water for 24 h, the bonded teeth were sectioned into 0.9 × 0.9 mm(2) sticks producing a minimum of 12 sticks per tooth. Four sticks from each tooth were prepared for hybrid layer evaluation by scanning electron microscope analysis. The remaining sticks were immersed in silver nitrate for 24 h for either nanoleakage evaluation along the bonded interfaces or after rupture. Nanoleakage samples were carbon coated and examined using backscattered electron mode. Well-established hybrid layers were observed in the groups luted with RelyX ARC. Nanoleakage evaluation revealed increase nanoleakage in groups treated with CHX for both resin cements. Group U100/CHX exhibited the most pronouncing nanoleakage expression along with porous zones adjacent to the CHX pretreated dentin. The results suggest a possible incompatibility between CHX and RelyX U100 that raises the concern that the use of CHX with self-adhesive cements may adversely affect resin-dentin bond.
Collapse
|
33
|
Muñoz MA, Luque I, Hass V, Reis A, Loguercio AD, Bombarda NHC. Immediate bonding properties of universal adhesives to dentine. J Dent 2013; 41:404-11. [PMID: 23499568 DOI: 10.1016/j.jdent.2013.03.001] [Citation(s) in RCA: 200] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Revised: 02/27/2013] [Accepted: 03/01/2013] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVES To evaluate the dentine microtensile bond strength (μTBS), nanoleakage (NL), degree of conversion (DC) within the hybrid layer for etch-and-rinse and self-etch strategies of universal simplified adhesive systems. METHODS forty caries free extracted third molars were divided into 8 groups for μTBS (n=5), according to the adhesive and etching strategy: Clearfil SE Bond [CSE] and Adper Single Bond 2 [SB], as controls; Peak Universal Adhesive System, self-etch [PkSe] and etch-and-rinse [PkEr]; Scotchbond Universal Adhesive, self-etch [ScSe] and etch-and-rinse [ScEr]; All Bond Universal, self-etch [AlSe] and etch-and-rinse [AlEr]. After restorations were constructed, specimens were stored in water (37°C/24h) and then resin-dentine sticks were prepared (0.8mm(2)). The sticks were tested under tension at 0.5mm/min. Some sticks from each tooth group were used for DC determination by micro-Raman spectroscopy or nanoleakage evaluation (NL). The pH for each solution was evaluated using a pH metre. Data were analyzed with one-way ANOVA and Tukey's test (α=0.05). RESULTS For μTBS, only PkSe and PkEr were similar to the respective control groups (p>0.05). AlSe showed the lowest μTBS mean (p<0.05). For NL, ScEr, ScSe, AlSe, and AlEr showed the lowest NL similar to control groups (p<0.05). For DC, only ScSe showed lower DC than the other materials (p<0.05). CONCLUSIONS Performance of universal adhesives was shown to be material-dependent. The results indicate that this new category of universal adhesives used on dentine as either etch-and-rinse or self-etch strategies were inferior as regards at least one of the properties evaluated (μTBS, NL and DC) in comparison with the control adhesives (CSE for self-etch and SB for etch-and-rinse).
Collapse
Affiliation(s)
- Miguel Angel Muñoz
- School of Dentistry, Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | | | | | | | | | | |
Collapse
|
34
|
Bonifácio CC, Shimaoka AM, de Andrade AP, Raggio DP, van Amerongen WE, de Carvalho RCR. Micro-mechanical bond strength tests for the assessment of the adhesion of GIC to dentine. Acta Odontol Scand 2012; 70:555-63. [PMID: 22250948 DOI: 10.3109/00016357.2011.640280] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND The aim of this study is to critically evaluate the bond strength (BS) of Glass-Ionomer Cements (GIC) to dentine with microtensile (μTBS) and microshear (μSBS) BS tests by assessing their rankings and failure patterns. METHODS Samples were made on flat dentine surfaces and submitted to μTBS and μSBS. The materials used were: high viscosity GIC (Ketac™ Molar Aplicap-KM), resin-modified GIC (Fuji II-FII), nano-filled resin-modified GIC (Ketac™ N100-N100) and an etch-and-rinse adhesive system with a composite resin (Adper™ Single Bond 2 and Z100™-Z100). All tests were performed with a Universal Testing Machine (24 h water storage, crosshead speed of 1 mm/min). Debonded surfaces were examined with a stereomicroscope (×40) to identify the failure mode. The data was analyzed with two-way ANOVA (p < 0.05) and LSD test. RESULTS Means were statistically different regarding the tests and materials, indicating that values for BS obtained for each material depend on the test performed. Failure analysis revealed that failures produced by μTBS were mainly cohesive for KM and FII. μSBS failures were mainly adhesive or mixed for all materials. For the μTBS, the rank was Z100 > FII > KM = N100, whereas for the μSBS it was Z100 = FII = KM > N100. CONCLUSION It may be concluded that distinct micro-mechanical tests present different failure patterns and rankings depending on the material to be considered.
Collapse
|
35
|
SEZINANDO ANA, PERDIGÃO JORGE, REGALHEIRO RITA. Dentin Bond Strengths of Four Adhesion Strategies after Thermal Fatigue and 6-Month Water Storage. J ESTHET RESTOR DENT 2012; 24:345-55. [DOI: 10.1111/j.1708-8240.2012.00531.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
36
|
Luque-Martinez IV, Mena-Serrano A, Muñoz MA, Hass V, Reis A, Loguercio AD. Effect of bur roughness on bond to sclerotic dentin with self-etch adhesive systems. Oper Dent 2012; 38:39-47. [PMID: 22770432 DOI: 10.2341/11-390-l] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To evaluate the effect of bur roughness on bond strength values and conditioner pattern of two-step self-etch adhesives applied on sclerotic dentin. METHODS The roots of 48 bovine incisors were removed and the crowns were divided into four groups: the control group (CO) teeth were left untreated or the teeth were slightly roughened with coarse-, medium-, or fine-grit diamond burs. Next, the teeth were subdivided and Clearfil SE Bond (CSE) and Adper SE Bond (ASE) were applied according to the manufacturers' instructions. Composite resin (Opallis) buildups were incrementally constructed on the bonded surfaces. After storage for 24 hours in distilled water at 37°C, the teeth were sectioned into sticks (area of 0.8 mm(2)). The sticks were stressed until failure by tensile forces (0.5 mm/min). Additionally, eight bovine teeth were treated as previously described, and after adhesive application, the surface was rinsed off and examined by scanning electron microscopy to measure the relative number of open tubules (OT). Data (MPa) were analyzed by two-way analysis of variance and Tukey test (p=0.05). RESULTS CO showed the highest bond strength values (p<0.05). As regards OT, the lowest mean was observed for CO (p<0.05) and the highest was found after application of CSE or ASE (p<0.05).
Collapse
Affiliation(s)
- I V Luque-Martinez
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Paraná, Brazil
| | | | | | | | | | | |
Collapse
|
37
|
Raposo LH, Armstrong SR, Maia RR, Qian F, Geraldeli S, Soares CJ. Effect of specimen gripping device, geometry and fixation method on microtensile bond strength, failure mode and stress distribution: Laboratory and finite element analyses. Dent Mater 2012; 28:e50-62. [DOI: 10.1016/j.dental.2012.02.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2011] [Revised: 11/29/2011] [Accepted: 02/20/2012] [Indexed: 10/28/2022]
|
38
|
Li J, Li H, Yun X, Fok ASL. A comparison of bond strengths measured using cantilever bending and micro-tensile methods. Dent Mater 2011; 27:1246-51. [PMID: 21955518 DOI: 10.1016/j.dental.2011.08.593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2010] [Revised: 08/26/2011] [Accepted: 08/30/2011] [Indexed: 10/17/2022]
Abstract
OBJECTIVES The purpose of this study was to evaluate the cantilever-bending test as a bond-strength measurement method for enamel/composite adhesion. MATERIALS AND METHODS The buccal surface of bovine incisors were flattened and subsequently placed with composite Z250 (3M ESPE) incrementally after either self-etching adhesive (SE) or etch-and-rinse adhesive (SB) was applied. Then, they were cut with a low-speed cutter to obtain stick-shape samples. The samples were divided into four groups (n=30 each) according to the adhesive and test method: SET, SE-B, SB-T and SB-B, where T denotes the microtensile test and B denotes the cantilever-bending test. The failure mode of each sample was examined under the microscope. Those samples with the fracture surface lying entirely or partially in the adhesive layer were considered to have provided successful measurements. The results from the two test methods were compared. RESULTS AND DISCUSSION The cantilever-bending method produced a comparable success rate of bond strength measurement to that of the microtensile method. The bond strengths of SE and SB from the cantilever-bending test were 58% and 40% higher, respectively, than those measured with the microtensile method. The adhesive SE exhibited almost the same bond strength as SB, irrespective of the test method. CONCLUSIONS Cantilever bending can be used as an alternative method for bond strength measurement. The ratio of bending to tensile strength is around 1.5.
Collapse
Affiliation(s)
- Jianying Li
- Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, USA.
| | | | | | | |
Collapse
|
39
|
Application of etch-and-rinse adhesives on dry and rewet dentin under rubbing action. J Am Dent Assoc 2011; 142:828-35. [DOI: 10.14219/jada.archive.2011.0272] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
40
|
Effect of metal primers on microtensile bond strength between zirconia and resin cements. J Prosthet Dent 2011; 105:296-303. [DOI: 10.1016/s0022-3913(11)60055-3] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
41
|
Belli R, Sartori N, Peruchi LD, Guimarães JC, Araújo E, Monteiro S, Baratieri LN, Lohbauer U. Slow progression of dentin bond degradation during one-year water storage under simulated pulpal pressure. J Dent 2010; 38:802-10. [PMID: 20599465 DOI: 10.1016/j.jdent.2010.06.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2010] [Revised: 06/15/2010] [Accepted: 06/23/2010] [Indexed: 10/19/2022] Open
Abstract
OBJECTIVES To evaluate the dentin bond durability of simplified adhesives after one-year (1 y) under water storage and simulated pulpal pressure. METHODS Class I cavities were prepared in sixty human third molars with the pulpal wall located in mid-coronal dentin. The roots were cut off to expose the pulpal chamber, and the teeth were assembled in a pulpal pressure simulator device. A two-step etch-and-rinse adhesive (Single Bond 2/SB), a two-step self-etch adhesive (Clearfil SE Bond/CSE), a three-step self-etch adhesive (Adper Scotchbond SE/SSE) and three all-in-one adhesives (Adper Easy Bond/EB, Clearfil S(3) Bond/S3 and Adhese One/AO) were applied according to manufacturers instructions. No enamel pre-etching was used for the self-etch systems. The cavities were filled with a composite (Z250, 3M ESPE) in four to five horizontal increments and individually cured. Immediately after the final cure, pulpal pressure was set to 15 cm H(2)O. After 24 h and 1 y under simulate pulpal pressure the teeth were cut following a 'nontrimming' microtensile test technique (n=30) and tested in tension. Kruskall-Wallis and post hoc multiple comparisons were used at alpha=0.05. Weibull statistics was applied to SB, CSE and EB. Fractographic analysis of debonded specimens was performed using scanning electron microscopy. RESULTS At 24 h and 1 y periods, SB showed higher bond strength means than all the others adhesives tested. CSE was not statistically different from EB at 24 h and from EB and SB at 1 y. EB showed bond strength statistically higher than the other three self-etch adhesives, which were not statistically different from each other at 24 h. AO showed significantly lower bond strength than all tested materials after 1 y. For all adhesives the mean bond strength at 1 y were not statistically different from the values measured at 24 h (p>0.05). Shifts in failure mode patterns and Weibull modulus decrease indicate some degree of bond degradation after the 1 y storage period. CONCLUSION One-year of simulated pulpal pressure did not affect dentin bond strength of simplified adhesives in Class I restorations. Signs of degradation were only revealed by fractographic analysis and reliability parameters.
Collapse
Affiliation(s)
- Renan Belli
- Department of Dentistry, School of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil.
| | | | | | | | | | | | | | | |
Collapse
|
42
|
Reis A, Zander-Grande C, Kossatz S, Stanislawczuk R, Manso A, de Carvalho RM, Loguercio AD. Effect of Mode of Application on the Microtensile Bond Strength of a Self-etch and Etch-and-Rinse Adhesive System. Oper Dent 2010; 35:428-35. [PMID: 20672727 DOI: 10.2341/09-319-l] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
All Bond 3 and All Bond Self-Etch are versatile systems, capable of being used either in the full or simplified version. Both showed adequate microtensile bond strength results in enamel and dentin after 24 hours of water storage.
Collapse
Affiliation(s)
- Alessandra Reis
- School of Dentistry, Department of Restorative Dentistry, University Estadual de Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | | | | | | | | | | | | |
Collapse
|
43
|
Armstrong S, Geraldeli S, Maia R, Raposo LHA, Soares CJ, Yamagawa J. Adhesion to tooth structure: A critical review of “micro” bond strength test methods. Dent Mater 2010; 26:e50-62. [DOI: 10.1016/j.dental.2009.11.155] [Citation(s) in RCA: 164] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2009] [Accepted: 11/23/2009] [Indexed: 10/20/2022]
|
44
|
Braga RR, Meira JB, Boaro LC, Xavier TA. Adhesion to tooth structure: A critical review of “macro” test methods. Dent Mater 2010; 26:e38-49. [DOI: 10.1016/j.dental.2009.11.150] [Citation(s) in RCA: 218] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2009] [Accepted: 11/19/2009] [Indexed: 11/24/2022]
|
45
|
Stanislawczuk R, Amaral RC, Zander-Grande C, Gagler D, Reis A, Loguercio AD. Chlorhexidine-containing acid conditioner preserves the longevity of resin-dentin bonds. Oper Dent 2009; 34:481-90. [PMID: 19678455 DOI: 10.2341/08-016-l] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The current study evaluated the effect of 2% chlorhexidine digluconate (CHX) on the immediate and six-month resin-dentin bond strength (BS) and nanoleakage pattern (NL) of etch-and-rinse adhesives when applied in aqueous or associated to the phosphoric acid conditioner. The occlusal enamel of 42 caries-free extracted molars was removed in order to expose a flat dentin surface. In groups 1 and 2 (control-C), the surfaces were acid etched with conventional phosphoric acid, and the adhesives Prime&Bond NT (PB) and Adper Single Bond 2 (SB) were applied after rinsing, drying and rewetting with water. In groups 3 and 4 (Ac/CHX), the adhesives were applied in a similar manner, however, a 2% CHX-containing acid was previously applied. In groups 5 and 6 (CHX), the adhesives were applied according to the control group; however, the rewetting procedure was performed with an aqueous solution of 2% CHX for 60 seconds. Composite buildups (Opallis, FGM) were constructed incrementally, and the specimens were longitudinally sectioned in the "x" and "y" directions to obtain bonded sticks (0.8 mm2) to be tested in tension at 0.5 mm/minute immediately or after six months of water storage. For NL, two bonded sticks from each tooth were coated with nail varnish, placed in silver nitrate and polished down with SiC paper. Resin-dentin interfaces were analyzed by EDX-SEM. The BS and NL data from each adhesive was submitted to two-way repeated measures ANOVA and Tukey's test (alpha=0.05). After six months of water storage, significant reductions in BS were observed for both adhesives in the control group (p<0.05). When Ac/CHX or CHX was used, no significant reductions in BS were observed for both systems. Nanoleakage was more evident in the control group than in the experimental groups (p<0.05), even after six months. The use of CHX in an aqueous solution or associated with the acid conditioner was effective for reducing degradation of resin-dentin bonds after six months of water storage.
Collapse
Affiliation(s)
- R Stanislawczuk
- Department of Restorative Dentistry, Universidade Estadual de Ponta Grossa, Ponta Grossa, Brazil
| | | | | | | | | | | |
Collapse
|
46
|
Carvalho APMC, Turbino ML. Can previous acid etching increase the bond strength of a self-etching primer adhesive to enamel? Braz Oral Res 2009; 23:169-74. [DOI: 10.1590/s1806-83242009000200013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2007] [Accepted: 08/21/2007] [Indexed: 11/22/2022] Open
|
47
|
Lodovici E, Reis A, Geraldeli S, Ferracane JL, Ballester RY, Rodrigues Filho LE. Does adhesive thickness affect resin-dentin bond strength after thermal/load cycling? Oper Dent 2009; 34:58-64. [PMID: 19192838 DOI: 10.2341/08-37] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study evaluated the influence of adhesive layer thickness (ADL) on the resin-dentin bond strength of two adhesive systems (AS) after thermal and mechanical loading (TML). A flat superficial dentin surface was exposed with 600-grit SiC paper on 40 molars. After primer application, the adhesive layer of Scotchbond Multipurpose (SBMP) or Clearfil SE Bond (CSEB) was applied in one or two layers to a delimited area (52 mm2) and resin blocks (Filtek Z250) were built incrementally. Half of the sample was stored in distilled water (37 degrees C, 24 hours) and submitted to thermal (1,000; 5 degrees -55 degrees C) and mechanical cycles (500,000; 10kgf) [TML]. The other half was stored in distilled water (72 hours). The teeth were then sectioned to obtain sticks (0.8 mm2) to be tested under tensile mode (1.0 mm/minute). The fracture mode was analyzed at 400x. The BS from all sticks from the same tooth was averaged for statistical purposes. The data was analyzed by three-way ANOVA. The chi2 test was used (p < 0.05) to compare the frequency of pre-testing failure specimens. Higher BS values were observed for SBMP regardless of the ADL. The TML reduced the BS values irrespective of the adhesive employed and the ADL. A higher frequency of pre-testing failure specimens was observed for the cycled groups. A thicker adhesive layer, acting as an intermediate flexible layer, did not minimize the damage caused by thermal/mechanical load cycling for a three-step etch-and-rinse and two-step self-etch system.
Collapse
Affiliation(s)
- Edmea Lodovici
- Department of Biomaterials and Oral Biochemistry, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | | | | | | | | | |
Collapse
|
48
|
Camargo MA, Roda MI, Marques MM, de Cara AA. Micro-tensile bond strength to bovine sclerotic dentine: Influence of surface treatment. J Dent 2008; 36:922-7. [DOI: 10.1016/j.jdent.2008.07.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2008] [Revised: 07/15/2008] [Accepted: 07/21/2008] [Indexed: 10/21/2022] Open
|
49
|
Tachibana A, Marques MM, Soler JMP, Matos AB. Erbium, chromium:yttrium scandium gallium garnet laser for caries removal: influence on bonding of a self-etching adhesive system. Lasers Med Sci 2007; 23:435-41. [PMID: 17963019 DOI: 10.1007/s10103-007-0503-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2007] [Accepted: 09/26/2007] [Indexed: 10/22/2022]
Abstract
This study evaluated the influence of the dental substrates obtained after the use of different caries removal techniques on bonding of a self-etching system. Forty, extracted, carious, human molars were ground to expose flat surfaces containing caries-infected dentine surrounded by sound dentine. The caries lesions of the specimens were removed or not (control--G1) either by round steel burs and water-cooled, low speed, handpiece (G2), or by irradiation with an erbium, chromium:yttrium scandium gallium garnet (Er,Cr:YSGG) laser (2W, 20 Hz, 35.38 J/cm(2), fiber G4 handpiece with 0.2826 mm(2), non-contact mode at a 2 mm distance, 70% air/20% water--G3) or using a chemo-mechanical method (Carisolv--G4). Caries-infected, caries-affected and sound dentines were submitted to a bonding system followed by construction of a resin-based composite crown. Hour-glass shaped samples were obtained and submitted to a micro-tensile bond test. The bond strength data were compared by analysis of variance (ANOVA), complemented by Tukey's test (P <or= 0.05). The samples of sound dentine presented higher bond strengths than did samples of caries-affected dentine, except for the groups treated with the Er,Cr:YSGG laser. The highest bond strengths were observed with the sound dentine treated with burs and Carisolv. The bond strengths to caries-affected dentine were similar in all groups. Additionally, bonding to caries-affected dentine of the Er,Cr:YSGG laser and Carisolv groups was similar to bonding to caries-infected dentine. Thus, caries-affected dentine is not an adequate substrate for adhesion. Moreover, amongst the caries removal methods tested, the Er,Cr:YSGG laser irradiation was the poorest in providing a substrate for bonding with the tested self-etching system.
Collapse
Affiliation(s)
- Arlene Tachibana
- Departamento de Dentística, Faculdade de Odontologia, Universidade de São Paulo, Av. Prof. Lineu Prestes, 2227 Cidade Universitária, São Paulo 05508-000, SP, Brazil.
| | | | | | | |
Collapse
|
50
|
Reis A, Pellizzaro A, Dal-Bianco K, Gones OM, Patzlaff R, Loguercio AD. Impact of adhesive application to wet and dry dentin on long-term resin-dentin bond strengths. Oper Dent 2007; 32:380-7. [PMID: 17695611 DOI: 10.2341/06-107] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study compared the effects of moisture and rubbing action on the immediate and one-year microtensile bond strength (BS) of an ethanol/water-based adhesive system (Single Bond [SB]) and an acetone-based system (One Step [OS]) to dentin. A flat superficial dentin surface on 60 human molars was exposed by wet abrasion. Two coats of the adhesives were applied on either a dry (D) or rewetted surface (W) with no (NRA), slight (SRA) or vigorous rubbing action (VRA). After light curing (600 mW/cm2/10 seconds), composite buildups were constructed incrementally and the specimens were stored in water (37 degrees C/24 hours). They were longitudinally sectioned in the "x" and "y" directions to obtain bonded sticks (0.8 mm2) to be tested in tension at 0.5 mm/minute. The sticks from each tooth were then divided, stored in water at 37 degrees C and tested immediately and after 12 months (12 M) at 0.5 mm/minute. The bond strength values of sticks from the same hemitooth were averaged for statistical purposes. The prematurely debonded specimens were included in the hemi-tooth mean. The data from each adhesive was analyzed by three-way ANOVA and Tukey's multiple comparison tests (alpha = 0.05). In the dry groups, high bond strength values were obtained under VRA. When the dentin was kept moist, both SRA and VRA provided high resin-dentin bond strength values. Reductions in bond strength values after one year of water storage were not observed for the SB adhesive or were less pronounced for the OS adhesive when it was vigorously rubbed onto the dentin surface.
Collapse
Affiliation(s)
- Alessandra Reis
- Department of Dental Materials and Operative Dentistry, University of Oeste de Santa Catarina, Joaçaba, SC, Brazil.
| | | | | | | | | | | |
Collapse
|