1
|
Gupta J, Taneja S, Bharti R, Bhalla V, Jain A. Effect of laser bleaching, ultrasonic scaling and powered tooth brushing on surface roughness and bacterial adherence of class V composite restorations. J Oral Biol Craniofac Res 2023; 13:429-435. [PMID: 37274090 PMCID: PMC10233206 DOI: 10.1016/j.jobcr.2023.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 02/24/2023] [Accepted: 03/25/2023] [Indexed: 06/06/2023] Open
Abstract
Objective To evaluate and compare the effect of diode laser assisted bleaching, ultrasonic scaling and powered tooth brushing on surface roughness and bacterial adherence on class V cavities restored with composites. Materials and methods A total of one hundred and twenty samples (40 samples each of Brilliant Everglow, Beautifil II and Heytec-N) were prepared in standardized stainless steel molds. The samples were further subdivided into four subgroups i.e. one control group (without any intervention) and three experimental groups - diode laser assisted bleaching, ultrasonic scaling and powered tooth brushing consisting of 10 sample each. Surface roughness was measured quantitatively with the help of 3D Optical Profilometer. For bacterial adherence analysis S. mutans strain (ATCC 25175) was cultured in BHI medium and samples were evaluated for the presence of viable bacteria using the Colony Forming Unit (CFU) count. Results obtained were then tabulated and subjected to statistical analysis. Results Diode laser bleaching caused a significant increase in surface roughness and bacterial adherence with lowest mean change exhibited by Heytec-N followed by Beautifil II and highest by Brilliant Everglow group. Similarly, Ultrasonic scaling increased the surface roughness of all the three tested samples with significant difference between the groups. Powered tooth brushing had no effect on the surface roughness and bacterial adherence of the tested composites. Conclusion Diode assisted laser bleaching and ultrasonic caused significantly higher surface roughness and bacterial adherence values for all the tested composites. It may therefore be recommended to do finishing and polishing of restorations after such procedures.
Collapse
Affiliation(s)
| | - S. Taneja
- Department of Conservative Dentistry and Endodontics, ITS Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India
| | - R. Bharti
- Department of Conservative Dentistry and Endodontics, Faculty of Dental Sciences, King George's Medical University, Lucknow, India
| | - V.K. Bhalla
- Department of Conservative Dentistry and Endodontics, ITS Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India
| | - A. Jain
- Department of Oral Pathology, ITS Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India
| |
Collapse
|
2
|
de Oliveira AG, Rocha RS, Spinola MDS, Batista GR, Bresciani E, Caneppele TMF. Surface smoothness of resin composites after polishing-A systematic review and network meta-analysis of in vitro studies. Eur J Oral Sci 2023; 131:e12921. [PMID: 36781294 DOI: 10.1111/eos.12921] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 01/21/2023] [Indexed: 02/15/2023]
Abstract
A systematic review and network meta-analysis was performed to provide evidence for the best polishing protocol for different types of resin composites to minimize surface roughness. A search was performed in PubMed, Scopus, Web of Science, LILACS, BBO, EMBASE, and Cochrane Library on July 2, 2019 (updated in December, 2020). In vitro studies that included at least two systems for polishing resin composites and analyzed surface roughness were included. The risk of bias was evaluated. A random-effects Bayesian-mixed treatment comparison model was used to compare surface roughness in resin composites with the different types of polishers. Surface under the cumulative ranking curve (SUCRA) analysis was performed to rank the probability for the best polishing system. After removal of duplicates, title and abstract screening yielded 34 studies. Network meta-analysis was not possible for hybrid and microhybrid composites. SUCRA analysis showed that abrasive paper discs allowed greater surface smoothness for nanohybrid and nanofill composites to a probability of between 83% and 91.6%. Silicon carbide brush had a 78.2% probability of being the best system for microfill composites. The use of abrasive paper disc polishers showed a favorable result in nanofill and nanohybrid resin composites. Silicon carbide brush has a greater chance of promoting a smoother surface for microfill resin composites.
Collapse
Affiliation(s)
- Ananda Gomes de Oliveira
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | - Rafael Santos Rocha
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | - Manuela da Silva Spinola
- Department of Restorative Dentistry, Braz Cubas University, São José dos Campos, São Paulo, Brazil
| | - Graziela Ribeiro Batista
- Department of Restorative Dentistry, Missouri School of Dentistry and Oral Health, A. T. Still University, São José dos Campos, São Paulo, Brazil
| | - Eduardo Bresciani
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | - Taciana Marco Ferraz Caneppele
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| |
Collapse
|
3
|
Gallo S, Colombo M, Poggio C, Scribante A, Saracino M, Beltrami R. Bleaching Effect of Ozonized Substances on Resin Composite: A New Potentiality for Ozone Therapy in Dentistry. APPLIED SCIENCES 2023; 13:2149. [DOI: 10.3390/app13042149] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Abstract
Composite resins are commonly used in dentistry for direct restorations. The color stability of these materials still represents a major concern for both the clinician and the patient. In recent years, ozone therapy has been extensively used in dentistry to manage wounds healing, dental caries, oral lichen planus, gingivitis and periodontitis, halitosis, osteonecrosis of the jaw, post-surgical pain, plaque and biofilms, root canal treatment, dentin hypersensitivity, temporomandibular joint disorders, and teeth whitening. To date, several studies have evaluated the bleaching effect exerted by ozone on natural teeth, but no studies have been conducted to determine the effect on the color of composite resins. The aim of the present study is to determine whether ozonized oils/gels could determine a color change on composite resin. A total of 40 discs of an A3 shade restorative composite were divided into two groups, respectively exposed to a pigmentation treatment consisting of 10 applications of 10 min each of a 1% chlorhexidine-based gel (trial group) and to storage into physiological solution (control group). The samples of both groups were respectively subdivided into four subgroups which underwent four different protocols, three of which were based on the exposure to different ozonized products and the latter representing the control. A colorimetric analysis with the CIELAB method was conducted with the following timing: after 24 h of storage in physiological solution (before the experimental procedures) (T0), after the subdivision into groups A and B (corresponding to the pigmentation for samples of group A and storage in physiological solution for samples of group B) (T1), and after subdivision into subgroups 1–4 (corresponding to the application of the ozonized products vs. control) (T2). No statistically significant difference was found between the samples at T0. The 20 samples of group A, exposed to the colorant agent, underwent a color change from T0 to T1, whereas the 20 samples exposed to the physiologic solution did not undergo any significant color change. A positive but moderate influence was assessed for E and L values, whereas no significant change occurred for A and B values. Therefore, dental ozonized oils/gels could be valuable in restorative dentistry as bleaching agents of resin composites exposed to discoloration, an alternative to the traditional hydrogen peroxide and carbamide peroxide, but further studies are required to confirm these findings.
Collapse
Affiliation(s)
- Simone Gallo
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | - Marco Colombo
- Unit of Restorative Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | - Claudio Poggio
- Unit of Restorative Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | - Andrea Scribante
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy
- Unit of Dental Hygiene, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | - Matilda Saracino
- Unit of Dental Hygiene, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | - Riccardo Beltrami
- Unit of Restorative Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy
| |
Collapse
|
4
|
Effects of surface roughness on the time-dependent wear performance of lithium disilicate glass ceramic for dental applications. J Mech Behav Biomed Mater 2021; 121:104638. [PMID: 34171718 DOI: 10.1016/j.jmbbm.2021.104638] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/31/2021] [Accepted: 06/05/2021] [Indexed: 11/21/2022]
Abstract
OBJECTIVES Purpose of the present study was to evaluate the effect of surface roughness on the time-dependent wear performance of lithium disilicate (LD) glass-ceramic. METHODS Friction pairs (pin and disk specimens) were prepared by IPS e.max® Press lithium disilicate glass-ceramic. The lateral faces of friction pairs (N = 12) were grinded with silicon carbide papers, and 6 friction pairs were polished with a 0.25 μm diamond suspension after grinding. The friction pairs were tested for wear performance using a pin-on-disk tribometer with 10 N for 1.02 × 106 wear cycles in artificial saliva. Wear analysis of the pin and disk was performed with a 3D profilometer. The microstructure and worn surface morphology were examined with scanning electron microscopy. One-way analysis of variance and Tukey's post-hoc pairwise comparison were used to analyze the wear data. RESULTS The two group LD friction pairs presented strong time-dependent wear performance. The polished group (GP) exhibited a high wear rate and extensive surface wear during 0-1 × 105 cycles (running-in wear stage). The wear rate, height loss and surface roughness were obviously lower than those of grinded group (GG) in running-in wear stage. However, these wear parameters were similar during the steady wear stage. The worn surface topographies of the pin and disk in GP were smoother at the same cycle before the GG entering the steady wear stage. CONCLUSION Running-in, which means the initial stage of wear process, is a critical period to determine the final wear loss and surface degradation, when compare the wear behavior of lithium disilicate ceramic with different initial surface states. Ceramic layer with smooth contact area leads to low wear rate and short running-in wear stage.
Collapse
|
5
|
Payaminia L, Moslemian N, Younespour S, Koulivand S, Alikhasi M. Evaluating the effect of repeated use of milling burs on surface roughness and adaptation of digitally fabricated ceramic veneers. Heliyon 2021; 7:e06896. [PMID: 33997414 PMCID: PMC8105639 DOI: 10.1016/j.heliyon.2021.e06896] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 02/18/2021] [Accepted: 04/20/2021] [Indexed: 11/15/2022] Open
Abstract
Objectives This study aimed to evaluate how repeated use of milling diamond burs with different coarseness affects surface roughness, and marginal and internal adaptation of CAD/CAM veneers. Methods Forty leucite-reinforced glass-ceramic veneers were milled in 2 groups based on the milling mode (with fine or extra-fine bur sets). In each group, every 10 veneers were milled with a new bur set. All veneers were cemented to bovine teeth and then polished. Labial surface roughness was measured before cementation, and after polishing. Marginal and internal discrepancies were measured using a field emission scanning electron microscope. Three-way and two-way mixed repeated measures ANOVA were applied to assess changes in surface roughness values of veneers and discrepancy values, respectively. The Bonferroni correction was applied for multiple comparisons. Results Repeated use of a milling diamond bur set had a significant effect on surface roughness of the veneers (P < .001). Mean surface roughness of the fine milling mode was significantly higher in comparison to that of extra-fine mode before (P = .002) and after (P = .01) polishing. After polishing a significant decrease in surface roughness occurred in fine (P = .02), but not in extra-fine milling mode (P = .99). Repeated use of milling burs significantly affected marginal and internal adaptation between some repeated uses. Conclusions Marginal and internal adaptation were significantly affected by repeated use of milling diamond burs up to 10 times between some repeated uses. However, no specific pattern could be established. Clinical significance Repeated use of milling burs could affect surface roughness, surface microcracks, critical defects, and adaptation of CAD/CAM restorations. Therefore, it plays a major role in clinical success of the restorations.
Collapse
Affiliation(s)
- Leila Payaminia
- Dental Research Center, Dental Implant Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran
| | - Naeime Moslemian
- Department of Prosthodontics, School of Dentistry, Hamedan University of Medical Sciences, Hamedan, Iran
| | - Shima Younespour
- Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Soudabeh Koulivand
- Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Marzieh Alikhasi
- Dental Research Center, Dental Implant Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Evaluation of the effect of different polishing systems on the surface roughness of dental ceramics. J Prosthet Dent 2020; 124:100-109. [DOI: 10.1016/j.prosdent.2019.07.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 06/16/2019] [Accepted: 07/05/2019] [Indexed: 11/20/2022]
|
7
|
Alkhudhairy FI. The effects of irradiance and exposure time on the surface roughness of bulk-fill composite resin restorative materials. Saudi Med J 2018; 39:197-202. [PMID: 29436570 PMCID: PMC5885098 DOI: 10.15537/smj.2018.2.21440] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVES To evaluate the surface roughness of 4 different bulk-fill resin-based composites cured using different irradiance levels. Methods: This in vitro study was performed in February 2017 to August 2017 at the College of Dentistry, King Saud University. Twenty-four specimens were prepared from each of the bulk-fill materials [Tetric N-Ceram (TNC), SonicFill (SF), Smart Dentin Replacement (SDR), and Filtek Bulk-Fill (FB)] using a brass metal mold, resulting in a total of 96 specimens, cured using a Bluephase N light curing unit. Half of the total number of specimens (N=48) were cured using high-power irradiance (1200 mW/cm2) for 20 seconds, while the remaining half (N=48) were cured using low power irradiance (650 mW/cm2) for 40 seconds. After 24 hours, baseline surface roughness of each specimen was analyzed using a profilometer, then polished using Sof-lex abrasive disks, and the surface roughness of all groups was assessed. Results: Post-polished SonicFill cured at high irradiance had the highest mean surface roughness (0.23±0.03), whereas pre-polished Smart Dentin Replacement (0.11±0.01) and SonicFill (0.11±0.02) cured at low irradiance had the lowest mean surface roughness. Conclusion: High curing irradiance (1,200 mW/cm2) had no positive influence on the surface roughness of Filtek Bulk Fill and Tetric N-Ceram bulk-fill RBCs compared with lower curing irradiance (650 mW/cm2). However, the difference of curing irradiance significantly affected the surface roughness in SDR and sonic fill RBCs.
Collapse
Affiliation(s)
- Fahad I Alkhudhairy
- Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia. E-mail.
| |
Collapse
|
8
|
Jang JH, Kim HY, Shin SM, Lee CO, Kim DS, Choi KK, Kim SY. Clinical Effectiveness of Different Polishing Systems and Self-Etch Adhesives in Class V Composite Resin Restorations: Two-Year Randomized Controlled Clinical Trial. Oper Dent 2018; 42:19-29. [PMID: 28002695 DOI: 10.2341/16-104-c] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this randomized controlled clinical trial was to compare the clinical effectiveness of different polishing systems and self-etch adhesives in class V composite resin restorations. A total of 164 noncarious cervical lesions (NCCLs) from 35 patients were randomly allocated to one of four experimental groups, each of which used a combination of polishing systems and adhesives. The two polishing systems used were Sof-Lex XT (Sof), a multistep abrasive disc, and Enhance/Pogo (EP), a simplified abrasive-impregnated rubber instrument. The adhesive systems were Clearfil SE bond (CS), a two-step self-etch adhesive, and Xeno V (XE), a one-step self-etch adhesive. All NCCLs were restored with light-cured microhybrid resin composites (Z250). Restorations were evaluated at baseline and at 6, 12, 18, and 24 months by two blinded independent examiners using modified FDI criteria. The Fisher exact test and generalized estimating equation analysis considering repeated measurements were performed to compare the outcomes between the polishing systems and adhesives. Three restorations were dislodged: two in CS/Sof and one in CS/EP. None of the restorations required any repair or retreatment except those showing retention loss. Sof was superior to EP with regard to surface luster, staining, and marginal adaptation (p<0.05). CS and XE did not show differences in any criteria (p>0.05). Sof is clinically superior to EP for polishing performance in class V composite resin restoration. XE demonstrates clinically equivalent bonding performance to CS.
Collapse
|
9
|
Color stability of different composite resins after polishing. Odontology 2018; 106:328-333. [PMID: 29330706 DOI: 10.1007/s10266-017-0337-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Accepted: 12/14/2017] [Indexed: 12/21/2022]
Abstract
The goals of the present study were to evaluate, in vitro, the staining of different composite resins submitted to different common beverages, and to compare the staining effect of each of these solutions. A total of 288 specimens were randomly divided into six groups and immersed for 4 weeks in five staining solutions represented by red wine, orange juice, coke, tea and coffee or in artificial saliva as a control group. When analyzed over a black background, mean ΔE00 values varied from 0.8 for Venus Diamond, Saremco Microhybrid and ELS in saliva and Estelite Posterior in coke to 37.6 for Filtek Supreme in red wine. When analyzed over a white background, mean ΔE00 values varied from 0.5 for Saremco Microhybrid in saliva to 51.1 for Filtek Supreme in red wine. All materials showed significant changes in color after 4 weeks of immersion in staining solutions. Significant differences were found between the tested composite resins and also between the staining solutions.
Collapse
|
10
|
O'Neill C, Kreplak L, Rueggeberg FA, Labrie D, Shimokawa CAK, Price RB. Effect of tooth brushing on gloss retention and surface roughness of five bulk-fill resin composites. J ESTHET RESTOR DENT 2017; 30:59-69. [DOI: 10.1111/jerd.12350] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Catherine O'Neill
- Dental Clinical Sciences; Dalhousie University; Halifax Nova Scotia Canada
| | - Laurent Kreplak
- Department of Physics and Atmospheric Science; Dalhousie University; Halifax Nova Scotia Canada
| | - Frederick A. Rueggeberg
- Department of Restorative Sciences, Dental College of Georgia; Augusta University; Augusta Georgia, USA
| | - Daniel Labrie
- Department of Physics and Atmospheric Science; Dalhousie University; Halifax Nova Scotia Canada
| | - Carlos Alberto Kenji Shimokawa
- Dental Clinical Sciences; Dalhousie University; Halifax Nova Scotia Canada
- School of Dentistry, Restorative Dentistry; University of São Paulo; Brazil
| | - Richard Bengt Price
- Department of Physics and Atmospheric Science; Dalhousie University; Halifax Nova Scotia Canada
| |
Collapse
|
11
|
Koc-Vural U, Baltacioglu I, Altinci P. Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks. Restor Dent Endod 2017; 42:118-124. [PMID: 28503477 PMCID: PMC5426223 DOI: 10.5395/rde.2017.42.2.118] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 01/14/2017] [Indexed: 11/11/2022] Open
Abstract
Objectives This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between 5 - 55℃, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex (Coltène/Whaledent), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at 37℃. The color differences (ΔE) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (α = 0.05). Results Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.
Collapse
Affiliation(s)
- Uzay Koc-Vural
- Department of Restorative Dentistry, Faculty of Dentistry, Hacettepe University, Ankara, Turkey
| | - Ismail Baltacioglu
- Department of Restorative Dentistry, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Pinar Altinci
- Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Finland
| |
Collapse
|
12
|
Color stability of recent composite resins. Odontology 2016; 105:29-35. [DOI: 10.1007/s10266-016-0234-9] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Accepted: 01/14/2016] [Indexed: 12/19/2022]
|
13
|
de Oliveira Lima M, Catelan A, Hernandes NMP, Giorgi MCC, Ambrosano GMB, Lima DANL. In vitro evaluation of the effect of different polishing techniques on the surface roughness of composite resins submitted to at-home and in-office bleaching procedures. J Conserv Dent 2016; 18:483-7. [PMID: 26752845 PMCID: PMC4693324 DOI: 10.4103/0972-0707.168820] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Objective: Bleaching agents may affect the properties of dental materials. The aim of this study was to evaluate the effect of different polishing techniques on the surface roughness of composite resins submitted to the at-home and in-office bleaching treatment. Materials and Methods: Disc-shaped specimens were carried out of nanofilled and microhybrid composites (n = 10). Finishing step was performed after light curing (L1) and polishing after 24 h with two systems (L2). Then, specimens were submitted to the home or in-office bleaching procedures, and roughness was re-evaluated (L3). The surface roughness (Ra) readings were measured at L1, L2, and L3 times using a profilometer. Data were statistically analyzed by multiple-way analysis of variance and Tukey test (α = 0.05). Results: The polishing procedures decreased Ra for both composites compared to baseline values (L1). The roughness of specimens polished with jiffy did not present significant difference after polishing step (L2) and bleaching treatment (L3). However, the groups polished with Sof-Lex discs had increase on the Ra values after bleaching. Conclusion: The polishing is an important procedure to reduce the roughness of dental restorations and composite surface polished with jiffy system improved the degradation resistance to the bleaching agents compared to Sof-Lex discs.
Collapse
Affiliation(s)
- Michele de Oliveira Lima
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Anderson Catelan
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Natália Maria Pinto Hernandes
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Maria Cecília Caldas Giorgi
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | | | - Débora Alves Nunes Leite Lima
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| |
Collapse
|
14
|
Gregor L, Krejci I, Di Bella E, Feilzer AJ, Ardu S. Silorane, ormocer, methacrylate and compomer long-term staining susceptibility using ΔE and ΔE 00 colour-difference formulas. Odontology 2015; 104:305-9. [PMID: 26178651 DOI: 10.1007/s10266-015-0212-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2015] [Accepted: 06/10/2015] [Indexed: 10/23/2022]
Abstract
The aim of this study was to evaluate the staining susceptibility of a silorane (Filtek Silorane), an ormocer (Ceram X Duo), a methacrylate (Tetric EvoCeram) and a compomer (Dyract) exposed on the long term to various staining agents by using ΔE and ΔE 00 colour-difference formulas. Thirty-six disc-shaped specimens were made of each of the four chemically different materials, randomly divided in six groups (n = 6) and immersed in five staining solutions (red wine, juice, coke, tea and coffee) or stored dry (control) in an incubator at 37 °C for 99 days. Spectrophotometric measurements by means of a spectrophotometer (Spectroshade Handy Dental, MHT) were repeated over a white (L* = 92.6, a* = -1.2, b* = 2.9) and black (L* = 1.6, a* = 1.2, b* = -1.0) background made of plasticized paper, in order to determine the colour changes according to ΔE, ΔE 00 and translucency formulas. Statistical analysis was performed by means of factorial Anova, Fisher's LSD test (post hoc) and a Spearman rank correlation between ΔE and ΔE 00. When analysed over a white background, mean ΔE 00 values were highly significantly different and varied from 0.8 (Ceram X Duo/air) to 20.9 (Ceram X Duo/red wine). When analysed over a black background, mean ΔE 00 values were highly significantly different and varied from 1.0 (Ceram X Duo and Tetric/air) to 25.2 (Ceram X Duo/red wine). Differences in translucency varied from 0.3 (Ceram X Duo/air) to 21.1 (Ceram X Duo/juice). The correlation between ΔE and ΔE 00 over a white background was 0.9928, while over a black background, it was 0.9886.
Collapse
Affiliation(s)
- Ladislav Gregor
- Division of Cariology and Endodontology, University Clinic of Dental Medicine (CUMD), University of Geneva, Rue Barthélemy-Menn 19, 1205, Geneva, Switzerland
| | - Ivo Krejci
- Division of Cariology and Endodontology, University Clinic of Dental Medicine (CUMD), University of Geneva, Rue Barthélemy-Menn 19, 1205, Geneva, Switzerland
| | - Enrico Di Bella
- Department of Economics and Quantitative Methods, University of Genoa, Genoa, Italy
| | - Albert J Feilzer
- Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University Amsterdam, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, The Netherlands
| | - Stefano Ardu
- Treatment Plan Unit and Division of Cariology and Endodontology, University Clinic of Dental Medicine (CUMD), University of Geneva, Rue Barthélemy-Menn 19, 1205, Geneva, Switzerland.
| |
Collapse
|
15
|
Jahanbin A, Basafa M, Moazzami M, Basafa B, Eslami N. Color Stability of Enamel following Different Acid Etching and Color Exposure Times. J Dent Res Dent Clin Dent Prospects 2014; 8:67-70. [PMID: 25093048 PMCID: PMC4120907 DOI: 10.5681/joddd.2014.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2013] [Accepted: 01/06/2014] [Indexed: 11/25/2022] Open
Abstract
Background and aims. The aim of this study was to evaluate the effect of different etching times on enamel color stability after immediate versus delayed exposure to colored artificial saliva (CAS).
Materials and methods. Human first premolars were divided into five groups of twenty. A colorimeter was used according to the CIE system on the mid-buccal and mid-lingual surfaces to evaluate initial tooth color. Samples in group A remained unetched. In groups B to E, buccal and lingual surfaces were initially etched with phosphoric acid for 15 and 60 seconds, respectively. Then, the samples in groups A and C were immersed in colored artificial saliva (cola+saliva). In group B, the teeth were immersed in simple artificial saliva (AS). Samples in groups D and E were immersed in AS for 24 and 72 hours, respectively before being immersed in colored AS. The teeth were immersed for one month in each solution before color measurement. During the test period, the teeth were retrieved from the staining solution and stored in AS for five minutes. This was repeated 60 times. Color changes of buccal and lingual surfaces were calculated. Kruskal-Wallis and Wilcoxon tests were used for statistical analysis (α ≤0.05). Results. There were no significant differences between the groups in term of ΔE of buccal (P = 0.148) and lingual surfaces (P = 0.73). Conclusion. Extended time of etching did not result in significant enamel color change. Immediate and delayed exposure of etched enamel to staining solutions did not result in clinically detectable tooth color changes.
Collapse
Affiliation(s)
- Arezoo Jahanbin
- Associate Professor, Department of Orthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Basafa
- Professor, Department of Orthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mostafa Moazzami
- Associate Professor, Department of Restorative Dentistry, Dental Research Center, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - Neda Eslami
- Assistant Professor, Department of Orthodontics, Dental Research Center, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
16
|
Yazici AR, Ustunkol I, Ozgunaltay G, Dayangac B. Three-year Clinical Evaluation of Different Restorative Resins in Class I Restorations. Oper Dent 2014; 39:248-55. [DOI: 10.2341/13-221-c] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The aim of the present study was to evaluate the three-year clinical performance of a nanofilled resin composite, a packable resin composite, and silorane-based resin restorations in Class I occlusal cavities. Twenty-eight patients with at least three similar-sized occlusal lesions in molar teeth participated in the study. A total of 84 Class I occlusal restorations were placed: 28 with nanofilled resin composite (Filtek Supreme), 28 with packable resin composite (P60), and 28 with silorane-based resin (Filtek Silorane). Filtek Supreme and P60 were used with their respective etch-and-rinse adhesive system, Adper Single Bond 2, and Filtek Silorane was used with its respective self-etch adhesive, Filtek Silorane Adhesive. All restorations were placed by the same operator. The restorations were evaluated at baseline, at six months, and annually for three years according to modified US Public Health Service criteria by two calibrated examiners who did not know which restorative resin had been used. The three restorative materials for each category were compared using the χ2 test at a significance level of 0.05. Cochran's Q test was used to compare the changes across the five time points for each restorative material. McNemar's test followed by Bonferroni adjustment was used when significance differences were found. At the end of the three years, 60 restorations were evaluated in 20 patients, with a recall rate of 71.4%. The retention rate was 100% for all restorative resins. Eight restorations from the P60 group, ten from the Filtek Supreme group, and nine from the Filtek Silorane group were rated Bravo for marginal discoloration. For marginal adaptation, three P60, five Filtek Supreme, and 11 Filtek Silorane restorations were rated Bravo. No statistically significant differences in overall clinical performance were found between the restorative materials except for marginal adaptation. P60 showed the best marginal adaptation at the end of the three years. No differences were observed between the restorative resins for any of the evaluation criteria tested (p>0.05). None of the restorations showed postoperative sensitivity, secondary caries, or loss of anatomic form. All restorative resins performed equally well in clinical conditions during the three-year evaluation, and no significant differences were found among them, except for marginal adaptation, in which P60 showed superior results.
Collapse
Affiliation(s)
- AR Yazici
- A. Ruya Yazici, DDS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey
| | - I Ustunkol
- Ildem Ustunkol, DDS, research assistant, Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey
| | - G Ozgunaltay
- Gul Ozgunaltay, DDS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey
| | - B Dayangac
- Berrin Dayangac, DDS, PhD, professor, Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey
| |
Collapse
|
17
|
Yew HZ, Berekally TL, Richards LC. A laboratory investigation of colour changes in two contemporary resin composites on exposure to spices. Aust Dent J 2013; 58:468-77. [DOI: 10.1111/adj.12099] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/03/2012] [Indexed: 11/29/2022]
Affiliation(s)
- HZ Yew
- Department of Operative Dentistry; Faculty of Dentistry; Universiti Kebangsaan Malaysia; Malaysia
| | - TL Berekally
- Adelaide Dental Hospital; South Australia Australia
| | - LC Richards
- Faculty of Health Sciences; The University of Adelaide; South Australia Australia
| |
Collapse
|
18
|
The effects of finishing and polishing techniques on surface roughness and color stability of nanocomposites. J Dent 2012; 40 Suppl 2:e64-70. [DOI: 10.1016/j.jdent.2012.07.005] [Citation(s) in RCA: 112] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2011] [Revised: 07/06/2012] [Accepted: 07/10/2012] [Indexed: 11/24/2022] Open
|
19
|
MARGHALANI HANADIY. Effect of Finishing/Polishing Systems on the Surface Roughness of Novel Posterior Composites. J ESTHET RESTOR DENT 2010; 22:127-38. [DOI: 10.1111/j.1708-8240.2010.00324.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
20
|
Perez CDR, Hirata RJ, da Silva AHMDFT, Sampaio EM, de Miranda MS. Effect of a glaze/composite sealant on the 3-D surface roughness of esthetic restorative materials. Oper Dent 2010; 34:674-80. [PMID: 19953776 DOI: 10.2341/08-014-l] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The main goal of the current study was to evaluate the surface roughness of tooth-colored restorative materials after different finishing/polishing protocols, including a liquid polisher (BisCover, BISCO, Schaumburg, IL, USA). The restorative materials tested included two nanofilled resin composites (Filtek Supreme, 3M Dental Products, St Paul, MN, USA and Grandio, Voco, Cuxhaven, Germany), one resin-modified glass ionomer cement (Vitremer, 3M Dental Products) and one conventional glass ionomer cement (Meron Molar ART, Voco). The finishing/polishing methods were divided into five groups: G1 (compression with Mylar matrix), G2 (finishing with diamond burs), G3 (Sof-Lex, 3M Dental Products), G4 (BisCover, BISCO, after diamond burs) and G5 (BisCover after Sof-Lex). Five cylindrical specimens of each material were prepared for each group according to the manufacturer's instructions. The finishing/polishing methods were performed by a single operator in one direction to avoid variations at low speed (15,000 RPM). The surface roughness was evaluated using a 3-D scanning instrument with two parameters considered (Ra and Rz). The data was analyzed using one-way ANOVA followed by a multiple comparison Tukey's test. The results showed that BisCover (BISCO) was capable of reducing surface roughness and provided polished surfaces for all materials, enhancing smoothness over already polished surfaces (Sof-Lex, 3M Dental Products) and achieving polishing after finishing with diamond burs.
Collapse
Affiliation(s)
- Cesar dos Reis Perez
- Department of Restorative Dentistry, School of Dentistry of State University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
| | | | | | | | | |
Collapse
|
21
|
|
22
|
Ertaş E, Güler AU, Yücel AC, Köprülü H, Güler E. Color stability of resin composites after immersion in different drinks. Dent Mater J 2006. [PMID: 16916243 DOI: 10.4012/dmj.25.371] [Citation(s) in RCA: 203] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The purpose of this study was to evaluate the discoloration of two nanohybrids, two microhybrids, and a posterior composite resin restorative material upon exposure to different drinks--namely tea, cola, coffee, red wine, and water. The colors of all specimens before and after storage in the solutions were measured by a colorimeter based on CIE Lab system, and the color differences thereby calculated. Data were analyzed by two-way analysis of variance (ANOVA) and Tukey's HSD test. According to ANOVA, the restorative material, staining agent, and their interaction were found to play a statistically significant role (P = 0.0001) in color change. Among the staining agents, water consistently showed the lowest deltaE* value for all materials, whereas red wine showed the highest deltaE* value. In other words, for all the materials tested, their color change in staining agents ranked in this increasing order: water < cola < tea < coffee < red wine. In terms of comparison among the five restorative materials, Filtek P60 and Z250 were observed to manifest less color change than the nanohybrids and Quadrant LC.
Collapse
Affiliation(s)
- Ertan Ertaş
- Department of Restorative Dentistry, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey.
| | | | | | | | | |
Collapse
|
23
|
Dresch W, Volpato S, Gomes JC, Ribeiro NR, Reis A, Loguercio AD. Clinical Evaluation of a Nanofilled Composite in Posterior Teeth: 12-month Results. Oper Dent 2006; 31:409-17. [PMID: 16924980 DOI: 10.2341/05-103] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
Nanofilled resin composite showed excellent clinical performance, similar to microhybrid and packable composites after 12-months.
Collapse
Affiliation(s)
- Walmor Dresch
- School of Dentistry, Department of Dental Materials and Operative Dentistry, University of Oeste de Santa Catarina, Campus Joaçaba/SC, Brazil
| | | | | | | | | | | |
Collapse
|
24
|
Loguercio AD, Reis A, Hernandez PAG, Macedo RP, Busato ALS. 3-Year clinical evaluation of posterior packable composite resin restorations. J Oral Rehabil 2006; 33:144-51. [PMID: 16457675 DOI: 10.1111/j.1365-2842.2006.01539.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This study evaluated the clinical performance of four packable resin composite restorative materials in posterior teeth (Class I and II) compared with one hybrid composite after 3 years. Eighty-four restorations were placed in 16 patients. The tested materials were: (i) Solitaire + Solid Bond; (ii) ALERT + Bond-1; (iii) Surefil + Prime & Bond NT; (iv) Filtek P60 + Single Bond and (v) TPH Spectrum + Prime & Bond 2.1. All restorations were made using rubber dam isolation, and the cavity design was restricted to the elimination of carious tissue. Deeper cavities were covered with calcium hydroxide and/or glass-ionomer cement. Each adhesive system and composite resin was placed according to the manufacturer's instructions. One week later, the restorations were finished/polished and evaluated according USPHS modified criteria. Fourteen patients attended the 3-year recall and 75 restorations were evaluated at that time based on the same evaluation criteria. Friedman repeated measures analysis of variance by rank and Wilcoxon sign-ranked test for pair-wise comparison was used for data analysis (alpha = 0.05). The analysis was performed only for the baseline and for the 3-year period. Solitaire showed some fractures at marginal ridges in 25% of the cases. Solitaire and ALERT showed some concerns related to colour match (43 and 77%, respectively) and surface texture (86 and 77%, respectively). TPH Spectrum showed a great percentage of colour mismatch after 3 years, around 50%. Surefil and Filtek P60 showed an excellent clinical performance after 3 years, similar to the hybrid resin tested, TPH Spectrum. Solitaire did not fulfil the ADA acceptance criteria for restorative materials and, therefore, is not recommended for use in posterior restorations.
Collapse
Affiliation(s)
- A D Loguercio
- Department of Dental Materials and Operative Dentistry, School of Dentistry, University of Oeste of Santa Catarina, UNOESC, Joaçaba, Brazil.
| | | | | | | | | |
Collapse
|