1
|
Hou S, Ma J, Cheng Y, Wang Z, Yan Y. Overview-gold nanoparticles-based sensitive nanosensors in mycotoxins detection. Crit Rev Food Sci Nutr 2023; 63:11734-11749. [PMID: 35916760 DOI: 10.1080/10408398.2022.2095973] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Food-borne mycotoxins is one of the food safety concerns in the world. At present, nanosensors are widely used in the detection and analysis of mycotoxins due to their high specificity and sensitivity. In nanosensor-based mycotoxindetections, the sensitivity is mainly improved from two aspects. On the one hand, based on the principle of immune response, antigens and antibodies can be modified and developed. Such as single-domain heavy chain antibodies, aptamers, peptides, and antigen mimotopes. On the other hand, improvements and innovations have been made on signal amplification materials, including gold nanoparticles (AuNPs), quantum dots, and graphene, etc. Among them, gold nanoparticles can not only be used as a signal amplification material, but also can be used as carriers for identification elements, which can be used for signal amplification in detection. In this article, we systematically summarized the emerging strategies for enhancing the detection sensitivity of traditional gold nanoparticles-based nanosensors, in terms of recognition elements and signal amplification. Representative examples were selected to illustrate the potential mechanism of each strategy in enhancing the colorimetric signal intensity of AuNP and its potential application in biosensing. Finally, our review suggested the challenges and future prospects of gold particles in detection of mycotoxins.
Collapse
Affiliation(s)
- Silu Hou
- Shanghai Key Laboratory of Veterinary Biotechnology, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai, China
| | - Jingjiao Ma
- Shanghai Key Laboratory of Veterinary Biotechnology, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai, China
| | - Yuqiang Cheng
- Shanghai Key Laboratory of Veterinary Biotechnology, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai, China
| | - Zhaofei Wang
- Shanghai Key Laboratory of Veterinary Biotechnology, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai, China
| | - Yaxian Yan
- Shanghai Key Laboratory of Veterinary Biotechnology, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
2
|
Sun W, Zhang Y, Ju Z. Mimotopes for Mycotoxins Diagnosis Based on Random Peptides or Recombinant Antibodies from Phage Library. Molecules 2021; 26:7652. [PMID: 34946736 PMCID: PMC8707711 DOI: 10.3390/molecules26247652] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/12/2021] [Accepted: 12/14/2021] [Indexed: 11/23/2022] Open
Abstract
Mycotoxins, the small size secondary metabolites of fungi, have posed a threat to the safety of medicine, food and public health. Therefore, it is essential to create sensitive and effective determination of mycotoxins. Based on the special affinity between antibody and antigen, immunoassay has been proved to be a powerful technology for the detection of small analytes. However, the tedious preparation and instability of conventional antibodies restrict its application on easy and fast mycotoxins detection. By virtue of simplicity, ease of use, and lower cost, phage display library provides novel choices for antibodies or hapten conjugates, and lead random peptide or recombinant antibody to becoming the promising and environmental friendly immune-reagents in the next generation of immunoassays. This review briefly describes the latest developments on mycotoxins detection using M13 phage display, mainly focusing on the recent applications of phage display technology employed in mycotoxins detection, including the introduction of phage and phage display, the types of phage displayed peptide/recombinant antibody library, random peptides/recombinant antibodies-based immunoassays, as well as simultaneous determination of multiple mycotoxins.
Collapse
Affiliation(s)
- Wei Sun
- Key Laboratory of Plant Physiology and Development Regulation, School of Life Science, Guizhou Normal University, Guiyang 550001, China; (W.S.); (Y.Z.)
| | - Yan Zhang
- Key Laboratory of Plant Physiology and Development Regulation, School of Life Science, Guizhou Normal University, Guiyang 550001, China; (W.S.); (Y.Z.)
| | - Zhigang Ju
- Pharmacy School, Guizhou University of Traditional Chinese Medicine, Guiyang 550025, China
| |
Collapse
|
3
|
Huang DT, Fu HJ, Huang JJ, Luo L, Lei HT, Shen YD, Chen ZJ, Wang H, Xu ZL. Mimotope-Based Immunoassays for the Rapid Analysis of Mycotoxin: A Review. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2021; 69:11743-11752. [PMID: 34583509 DOI: 10.1021/acs.jafc.1c04169] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Mycotoxins are toxic contaminants in foods and feeds that are naturally occurring and largely unavoidable. Determining their contents in these products is essential to protect humans from harm. Immunoassays of mycotoxins have been well-established because they are fast, sensitive, simple, and cost-effective. However, a major limitation of immunoassays is the requirement of toxic mycotoxins as competing antigens, standards, or competing tracers. Mimotopes are peptides or proteins that can specifically bind to antibodies and compete with analytes for binding sites by mimicking antigenic epitopes. They can be employed as substitutes for competing antigens, standards, or competing tracers to avoid use of mycotoxins. This review summarizes the production and functionalization of the two main kinds of mimotopes, mimic peptides and anti-idiotypic antibodies (Ab2), and their applications in rapid analysis of mycotoxins.
Collapse
Affiliation(s)
- Dan-Tong Huang
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Hui-Jun Fu
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Jia-Jia Huang
- Guangdong Food and Drug Vocational College, Guangzhou 510665, China
| | - Lin Luo
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Hong-Tao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Yu-Dong Shen
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Zi-Jian Chen
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Hong Wang
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Zhen-Lin Xu
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| |
Collapse
|
4
|
Zhou J, Chen F, Li J, Li C, Qi Y, Liu H, Zhang G, Wang A. Biopanning the mimotopes of aflatoxin B1 and their immunogenicity. ARQ BRAS MED VET ZOO 2020. [DOI: 10.1590/1678-4162-11372] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Affiliation(s)
- J. Zhou
- Academy of Life Sciences of Zhengzhou University, China
| | - F. Chen
- Wowen&infants Hospital of Zhengzhou, China
| | - J. Li
- Academy of Life Sciences of Zhengzhou University, China
| | - C. Li
- Academy of Life Sciences of Zhengzhou University, China
| | - Y. Qi
- Academy of Life Sciences of Zhengzhou University, China
| | - H. Liu
- Academy of Life Sciences of Zhengzhou University, China
| | - G. Zhang
- Academy of Life Sciences of Zhengzhou University, China
| | | |
Collapse
|
5
|
Cyclic peptide: a safe and effective alternative to synthetic aflatoxin B1-competitive antigens. Anal Bioanal Chem 2019; 411:3881-3890. [DOI: 10.1007/s00216-019-01862-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 04/10/2019] [Accepted: 04/23/2019] [Indexed: 12/30/2022]
|
6
|
de Andrade CYT, Yamanaka I, Schlichta LS, Silva SK, Picheth GF, Caron LF, de Moura J, de Freitas RA, Alvarenga LM. Physicochemical and immunological characterization of chitosan-coated bacteriophage nanoparticles for in vivo mycotoxin modeling. Carbohydr Polym 2018; 185:63-72. [DOI: 10.1016/j.carbpol.2017.12.063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 12/06/2017] [Accepted: 12/22/2017] [Indexed: 10/18/2022]
|
7
|
Hua X, Zhou L, Feng L, Ding Y, Shi H, Wang L, Gee SJ, Hammock BD, Wang M. Competitive and noncompetitive phage immunoassays for the determination of benzothiostrobin. Anal Chim Acta 2015; 890:150-6. [PMID: 26347177 DOI: 10.1016/j.aca.2015.07.056] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Revised: 07/16/2015] [Accepted: 07/30/2015] [Indexed: 01/03/2023]
Abstract
Twenty-three phage-displayed peptides that specifically bind to an anti-benzothiostrobin monoclonal antibody (mAb) in the absence or presence of benzothiostrobin were isolated from a cyclic 8-residue peptide phage library. Competitive and noncompetitive phage enzyme linked immunosorbent assays (ELISAs) for benzothiostrobin were developed by using a clone C3-3 specific to the benzothiostrobin-free mAb and a clone N6-18 specific to the benzothiostrobin immunocomplex, respectively. Under the optimal conditions, the half maximal inhibition concentration (IC50) of the competitive phage ELISA and the concentration of analyte producing 50% saturation of the signal (SC50) of the noncompetitive phage ELISA for benzothiostrobin were 0.94 and 2.27 ng mL(-1), respectively. The noncompetitive phage ELISA showed higher selectivity compared to the competitive. Recoveries of the competitive and the noncompetitive phage ELISAs for benzothiostrobin in cucumber, tomato, pear and rice samples were 67.6-119.6% and 70.4-125.0%, respectively. The amounts of benzothiostrobin in the containing incurred residues samples detected by the two types of phage ELISAs were significantly correlated with that detected by high-performance liquid chromatography (HPLC).
Collapse
Affiliation(s)
- Xiude Hua
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing 210095, China
| | - Liangliang Zhou
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing 210095, China
| | - Lu Feng
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing 210095, China
| | - Yuan Ding
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing 210095, China
| | - Haiyan Shi
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing 210095, China
| | - Limin Wang
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing 210095, China
| | - Shirley J Gee
- Department of Entomology and UCD Cancer Center, University of California, Davis, CA 95616, United States
| | - Bruce D Hammock
- Department of Entomology and UCD Cancer Center, University of California, Davis, CA 95616, United States
| | - Minghua Wang
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; State & Local Joint Engineering Research Center of Green Pesticide Invention and Application, Nanjing 210095, China.
| |
Collapse
|
8
|
Xu Y, He Z, He Q, Qiu Y, Chen B, Chen J, Liu X. Use of cloneable peptide-MBP fusion protein as a mimetic coating antigen in the standardized immunoassay for mycotoxin ochratoxin A. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2014; 62:8830-8836. [PMID: 25127400 DOI: 10.1021/jf5028922] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The quality of mycotoxin conjugates is essential to the development of reliability of immunoassays for mycotoxins. However, conventional mycotoxin conjugates are usually synthesized by chemical methods, which are harmful to the environment and yield unwanted cross-reactions. In this study, using ochratoxin A (OTA) as a model system, a selected OTA mimotope (phage-displayed peptide) that specifically binds to anti-OTA antibody was expressed as soluble and monovalent fusions to maltose binding protein (MBP). These prepared fusion proteins can serve as a mimetic coating antigen in both a quantitative chemiluminescent enzyme-linked immunoassay (CLEIA) and a qualitative dot immunoassay for OTA. One of the prepared mimetic coating antigen (L12-206-MBP)-based CLEIAs exhibited a half-inhibition concentration (IC50) of 0.82 ng/mL and a working range of 0.30-2.17 ng/mL, which resemble those of the conventional OTA-OVA conjugate-based immunoassay. The dot immunoassay developed with both the OTA-OVA conjugate and the mimetics showed identical visual cutoff values of 5 ng/mL. The mimetic coating antigen proposed here is an OTA-free product and can be prepared reproducibly as a homogeneous product and facilitates standardization of immunoassays for the mycotoxin OTA.
Collapse
Affiliation(s)
- Yang Xu
- State Key Laboratory of Food Science and Technology, Sino-Germany Joint Research Institute, Nanchang University , No. 235 Nanjing East Road, Nanchang 330047, China
| | | | | | | | | | | | | |
Collapse
|
9
|
Li W, Powers S, Dai S. Using commercial immunoassay kits for mycotoxins: ‘joys and sorrows’? WORLD MYCOTOXIN J 2014. [DOI: 10.3920/wmj2014.1715] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Rapid test methods are widely used for measuring mycotoxins in a variety of matrices. This review presents an overview of the current commercially available immunoassay rapid test formats. Enzyme linked immune-sorbent assay (ELISA), lateral flow tests, flow through immunoassay, fluorescent polarisation immunoassay, and immunoaffinity columns coupled with fluorometric assay are common formats in the current market. The two existing evaluation programs for commercial testing kits by United State Department of Agricultural Grain Inspection, Packers & Stockyards Administration (USDA-GIPSA) and AOAC Research Institute are introduced. The strengths and weaknesses of these test kits are discussed with regard to the application scope, variance, specificity and cross reactivity, accuracy and precision, and measurement range. Generally speaking, the current commercially available testing kits meet research and industrial needs as ‘fit-for-purpose’. Furthermore, quality assurance concerns and future perspectives are elaborated for broader application of commercial test kits in research, industry and regulatory applications. It is expected that new commercial kits based on advanced technologies such as electrochemical affinity biosensors, molecularly imprinted polymers, surface plasmon resonance, fluorescence resonance energy transfer, aptamer-based biosensors and dynamic light scattering might be available to users in the future. Meanwhile, harmonisation of testing kit evaluation, incorporation of more quality assurance into the testing kit utilisation scheme, and a larger variety of kits available at lower cost will expand the usage of testing kits for food safety testing worldwide.
Collapse
Affiliation(s)
- Wei Li
- Office of the Texas State Chemist, Texas A&M University, 445 Agronomy Road, College Station, TX 77843, USA
| | - S. Powers
- VICAM, 34 Maple Street, Milford, MA 02157, USA
| | - S.Y. Dai
- Department of Veterinary Pathobiology, Texas A&M University, College Station, 77843, USA
| |
Collapse
|
10
|
Wang Y, Li P, Majkova Z, Bever CRS, Kim HJ, Zhang Q, Dechant JE, Gee SJ, Hammock BD. Isolation of alpaca anti-idiotypic heavy-chain single-domain antibody for the aflatoxin immunoassay. Anal Chem 2013; 85:8298-303. [PMID: 23965250 DOI: 10.1021/ac4015885] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Anti-idiotypic antibodies recognize the antigenic determinants of an antibody, thus they can be used as surrogate antigens. Single-domain antibodies from camlid heavy-chain antibodies with the benefit features of small size, thermostability, and ease in expression, are leading candidates to produce anti-idiotypic antibodies. In this work, we constructed an antibody phage library from the mRNA of an alpaca immunized with an antiaflatoxin monoclonal antibody (mAb) 1C11. Three anti-idiotypic VHH antibodies were isolated and applied to immunoassay toward aflatoxin as a coating antigen. The best immunoassay developed with one of these VHH antibodies shows an IC50 of 0.16 ng/mL toward aflatoxin B1 and cross-reactivity toward aflatoxin B2, G1, and G2 of 90.4%, 54.4%, and 37.7%, respectively. The VHH-based immunoassay was successfully applied to the analysis of peanuts, corn, and rice, which are the predominant commodities regularly contaminated by aflatoxins. A good correlation (r(2) = 0.89) was found between the data obtained from the conventional ELISA and the ELISA based on a VHH coating antigen for the analysis of aflatoxins in peanuts and feedstuff. The use of biotechnology in developing the surrogate, the absence of standard aflatoxin and organic solvents in the synthesis procedures, and the reproducibility of the VHH antibody makes it an ideal strategy for replacing conventional synthesized antigens.
Collapse
Affiliation(s)
- Yanru Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, P. R. China
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Wang Y, Wang H, Li P, Zhang Q, Kim HJ, Gee SJ, Hammock BD. Phage-displayed peptide that mimics aflatoxins and its application in immunoassay. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2013; 61:2426-33. [PMID: 23394544 PMCID: PMC3830680 DOI: 10.1021/jf4004048] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
To search for an alternative to using protein conjugated aflatoxin as a coating antigen in aflatoxin detection by an ELISA method, a random-8-peptide library was constructed and used as a source of peptides that mimic aflatoxins (termed as mimotopes). Five mimotope peptides were obtained by panning-elution from the library and were successfully used in an indirect competitive ELISA for analyzing total aflatoxin concentration. The assay exhibited an IC50 value of 14 μg/kg in samples (with 1 in 7 dilution of sample extract) for aflatoxins. The linear range is 4-24 μg/kg. Further validation indicated relatively good recovery (60-120%) in peanut, rice and corn. Natural contaminated samples (peanut and feedstuff) were analyzed for aflatoxin concentration by both conventional ELISA and phage ELISA. The results showed good correlation. It can be concluded that the mimotope preparation is an effective substitute for the aflatoxin based coating antigen in ELISA and can be used in real sample analysis.
Collapse
Affiliation(s)
- Yanru Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, 430062, P. R. China
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, 430062, P. R. China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, 430062, P.R. China
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, 430062, P. R. China
| | - Hong Wang
- Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, California 95616, United States
| | - Peiwu Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, 430062, P. R. China
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, 430062, P. R. China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, 430062, P.R. China
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, 430062, P. R. China
- Corresponding Authors Tel: +86 27 86812943; Fax: +86 27 86812862;
| | - Qi Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, 430062, P. R. China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, 430062, P.R. China
| | - Hee Joo Kim
- Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, California 95616, United States
| | - Shirley J. Gee
- Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, California 95616, United States
| | - Bruce D. Hammock
- Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, California 95616, United States
| |
Collapse
|