1
|
He S, Hu R, Yao X, Cui J, Liu H, Zhu M, Ning L. The effects of heat and hydrogen peroxide treatment on the osteoinductivity of demineralized cortical bone: a potential method for preparing tendon/ligament repair scaffolds. Regen Biomater 2024; 11:rbae116. [PMID: 39398284 PMCID: PMC11471265 DOI: 10.1093/rb/rbae116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 08/12/2024] [Accepted: 09/07/2024] [Indexed: 10/15/2024] Open
Abstract
Recent studies have indicated that demineralized cortical bone (DCB) may be used to repair tendons and ligaments, such as the patellar tendon and anterior cruciate ligament (ACL). Hydrogen peroxide (H2O2) has been shown to reduce the osteoinductivity of DCB, and heat treatment may also decrease the osteoinductivity of DCB. The purpose of this study was (i) to determine whether heat treatment reduces the osteoinductivity of DCB and (ii) to compare the effectiveness of heat treatment and H2O2 treatment on BMP-2 inactivation. DCB was prepared by immersion in 0.6 N hydrochloric acid, and DCB-H and DCB-HO were prepared by heat treatment (70°C for 8 h) and H2O2 treatment (3% H2O2 for 8 h), respectively. The surface topographies, elemental distributions and histological structures of the scaffolds were observed by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR) and histological staining. The viability and osteogenic differentiation of TDSCs cultured on the scaffolds were evaluated via live/dead cell staining and Cell Counting Kit-8 (CCK-8) testing, real-time polymerase chain reaction (RT-PCR) and western bolt (WB) analysis, alkaline phosphatase activity (ALP) and alizarin red S (ARS) staining. The intramuscular implantation of the scaffolds in rats was also used to evaluate the effect of heat treatment and H2O2 treatment on the osteoinductivity of DCB. Our results demonstrated that both treatments removed BMP-2 and osteocalcin (OCN) within the DCB and that DCB-H and DCB-HO had good cytocompatibility and reduced the osteogenic differentiation of TDSCs. Moreover, the in vivo results indicated that the DCB-H and DCB-HO groups had smaller areas of osteoid formation than did the DCB group, and the DCB-HO group had the smallest area among the three groups. Our study demonstrated that heat treatment could reduce the osteoinductivity of DCB, and that H2O2 treatment was more effective than heat treatment.
Collapse
Affiliation(s)
- Shukun He
- Department of Orthopedic Surgery and Orthopedic Research Institute, Stem Cell and Tissue Engineering Research Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, 610041, China
- Department of Orthopedics, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, 310058, China
| | - Ruonan Hu
- Department of Orthopedic Surgery and Orthopedic Research Institute, Stem Cell and Tissue Engineering Research Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Xuan Yao
- Department of Clinical Hematology, Faculty of Laboratory Medicine, Army Medical University, Chongqing, 400038, China
| | - Jing Cui
- Department of Orthopedic Surgery and Orthopedic Research Institute, Stem Cell and Tissue Engineering Research Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Huimin Liu
- Department of Orthopedic Surgery and Orthopedic Research Institute, Stem Cell and Tissue Engineering Research Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Min Zhu
- Department of Orthopedic Surgery and Orthopedic Research Institute, Stem Cell and Tissue Engineering Research Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Liangju Ning
- Department of Orthopedic Surgery and Orthopedic Research Institute, Stem Cell and Tissue Engineering Research Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, 610041, China
| |
Collapse
|
2
|
Comparison of the mechanical properties and mechanical damages to tendon tissue in three suspensory fixation techniques. Asia Pac J Sports Med Arthrosc Rehabil Technol 2022; 30:1-8. [PMID: 35949263 PMCID: PMC9343929 DOI: 10.1016/j.asmart.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 03/26/2022] [Accepted: 05/23/2022] [Indexed: 11/30/2022] Open
Abstract
Background Anterior cruciate ligament (ACL) injury is the most common traumatic injury to the knee joint. Suspensory fixation has become popular in ACL reconstruction because of its high primary stability, less invasiveness, and surgical convenience. There are two common types of suspensory fixation devices: those with fixed-length and those with adjustable-length loops. Owing to structural differences and differences in initial tensioning techniques, it is expected that mechanical property and damage to the tendons will vary from device to device; however, no literature has examined this so far. The main purpose of this study was to evaluate the damage caused to the tendon by three different suspensory fixation devices. An effective mechanical test was carried out as a prerequisite. Methods First, the mechanical properties of simple loop device (SLD) as fixed-length loop device, first-generation, and second-generation adjustable devices (AD1 and AD2) as adjustable-length loop devices were tested (isolated device testing). Second, each device was tested using bovine extensor tendons (specimen testing). Cyclic testing included 2000 cycles; the devices were subsequently displaced until failure, and the ultimate tensile strength was determined using isolated device testing. Six samples of 3 devices were used in each testing experiment. After specimen testing, the surface structure of the tendon was evaluated quantitatively using optical coherence tomography (OCT) and our original histological scoring system. Results During isolated device testing, SLD demonstrated the least cyclic displacement, followed by AD1 and AD2. The highest ultimate tensile strength was observed in AD2, followed by SLD and AD1. In specimen testing, the least cyclic displacement was observed in SLD, followed by AD1 and AD2. Histologically, AD1 demonstrated a significantly lower score, with damaged surface morphology, than SLD and AD2. OCT values were significantly higher, with a more disturbing tendon surface structure, in AD1 than in SLD and AD2. Conclusions The first-generation adjustable loop device exhibited greatest graft tissue damage at the suspensory site in a clinically relevant setting. The thinner adjustable loop mechanism may have elevated graft damage by frictional stresses during loop adjustment or by repetitive tensioning stresses.
Collapse
|
3
|
Abstract
Degenerative disease of the intervertebral discs (DDD) is currently a serious problem facing the world community. The surgical methods and conservative therapy used today, unfortunately, do not stop the pathological process, but serve as a palliative method that temporarily relieves pain and improves the patient’s quality of life. Therefore, at present, there is an active search for new methods of treating DDD. Among new techniques of treatment, biological methods, and minimally invasive surgery, including the use of laser radiation, which, depending on the laser parameters, can cause ablative or modifying effects on the disc tissue, have acquired considerable interest. Here, we analyze a new approach to solving the DDD problem: laser tissue modification. This review of publications is focused on the studies of the physicochemical foundations and clinical applications of a new method of laser reconstruction of intervertebral discs. Thermomechanical action of laser radiation modifies tissue and leads to its regeneration as well as to a long-term restoration of disc functions, elimination of pain and the return of patients to normal life.
Collapse
|
4
|
Ignatieva N, Zakharkina O, Dadasheva A, Shekhter A, Sviridov A, Lunin V. Transformation of the dermal collagen framework under laser heating. JOURNAL OF BIOPHOTONICS 2019; 12:e201960024. [PMID: 31454461 DOI: 10.1002/jbio.201960024] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 08/10/2019] [Accepted: 08/25/2019] [Indexed: 06/10/2023]
Abstract
The aim of this study was to compare between the changes undergone by the dermal collagen framework when heated by IR laser radiation and by traditional means and to reveal the specific features of the dermal matrix modification under moderate IR laser irradiation. Rabbit skin specimens were heated to 50°C, 55°C, 60°C and 65°C in a calorimeter furnace and with a 1.68-μm fiber Raman laser. The proportion of the degraded collagen macromolecules was determined by differential scanning calorimetry. Changes in the architectonics of the collagen framework were revealed by using standard, phase-contrast, polarization optical and scanning electron microscopy techniques. The collagen denaturation and dermal matrix amorphization temperature in the case of laser heating proved to be lower by 10°C than that for heating in the calorimeter furnace. The IR laser treatment of the skin was found to cause a specific low-temperature (45°C-50°C) transformation of its collagen framework, with some collagen macromolecules remaining intact. The transformation reduces to the splitting of collagen bundles and distortion of the course of collagen fibers. The denaturation of collagen macromolecules in the case of traditional heating takes its course in a threshold manner, so that their pre-denaturation morphological changes are insignificant.
Collapse
Affiliation(s)
| | - Olga Zakharkina
- Institute of Photon Technologies, Federal Scientific Research Centre "Crystallography and Photonics" of Russian Academy of Sciences, Moscow, Russian Federation
| | - Aygun Dadasheva
- Department of Chemistry, Lomonosov Moscow State University, Baku Branch, Baku, Azerbaijan
| | - Anatoly Shekhter
- Institute for Regenerative Medicine, I M Sechenov First Moscow State Medical University, Moscow, Russian Federation
| | - Alexander Sviridov
- Institute of Photon Technologies, Federal Scientific Research Centre "Crystallography and Photonics" of Russian Academy of Sciences, Moscow, Russian Federation
| | - Valery Lunin
- Lomonosov Moscow State University, Moskva, Russian Federation
| |
Collapse
|
5
|
Abstract
Laser spine surgery has been a focus of intense interest in the lay press and among patients. On the Internet, a host of purported benefits to laser surgery exists. Lasers have long been used in pain management procedures such as percutaneous diskectomy. However, a few published articles are available on lasers in conventional spine surgery. From our review of the literature, the purported advantages of lasers, such as reduced inflammation and degeneration, are not been supported by preclinical research. The available clinical studies do not show a notable advantage for laser surgery. Moreover, the low enrollment, nonblinded, retrospective studies that are available are heavily subject to bias. The documented advantages of laser spine surgery described in the research studies are not consistent with the public's impression of its purported benefits. Furthermore, laser-specific complications are present about which patients should be informed. On the basis of the current research, we conclude that lasers add distinct potential complications without any corresponding clinical benefit. Because of the public interest, we feel that this is an important topic for the general orthopaedic community.
Collapse
|
6
|
Ignat’eva NY, Zakharkina OL, Dadasheva AR, Sadekova AR, Bagratashvili VN, Lunin VV. Features of Laser-Induced Modification of Sclera and Cornea. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A 2018. [DOI: 10.1134/s0036024418040076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
7
|
Sapogova N, Bredikhin V, Bityurin N, Kamensky V, Zhigarcov V, Yusupov V. Model for indirect laser surgery. BIOMEDICAL OPTICS EXPRESS 2017; 8:104-111. [PMID: 28101404 PMCID: PMC5231284 DOI: 10.1364/boe.8.000104] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Revised: 11/23/2016] [Accepted: 12/05/2016] [Indexed: 05/11/2023]
Abstract
We present a theoretical model for laser cutting of biological tissue by a strongly heated fiber tip with a highly absorbing coating. A significant dependence of the cutting speed and cutting depth on the inclination angle of the scalpel to the surface when scattering exceeds absorption in the biological tissue is shown. Experimental evidences of this effect are presented. In the experiment, we used silica fiber with coating made of carbon and silicon organic varnish, the 0.97-µm wavelength laser and porcine skin. The additional opportunity to increase the efficiency of cutting by deposition of the absorbing layer on the tissue surface is considered.
Collapse
Affiliation(s)
- Natalia Sapogova
- Institute of Applied Physics of the Russian Academy of Science, Federal State Budgetary Institution of Science, 46 Ulyanova Street, Nizhny Novgorod, 603950, Russia
| | - Vladimir Bredikhin
- Institute of Applied Physics of the Russian Academy of Science, Federal State Budgetary Institution of Science, 46 Ulyanova Street, Nizhny Novgorod, 603950, Russia
| | - Nikita Bityurin
- Institute of Applied Physics of the Russian Academy of Science, Federal State Budgetary Institution of Science, 46 Ulyanova Street, Nizhny Novgorod, 603950, Russia
| | - Vladislav Kamensky
- Institute of Applied Physics of the Russian Academy of Science, Federal State Budgetary Institution of Science, 46 Ulyanova Street, Nizhny Novgorod, 603950, Russia
| | - Vjacheslav Zhigarcov
- Institute of Photon Technologies of Federal Scientific Research Center, “Crystallography and Photonics” RAS, Troitsk, Moscow 142190, Russia
| | - Vladimir Yusupov
- Institute of Photon Technologies of Federal Scientific Research Center, “Crystallography and Photonics” RAS, Troitsk, Moscow 142190, Russia
| |
Collapse
|
8
|
Maslennikova A, Kochueva M, Ignatieva N, Vitkin A, Zakharkina O, Kamensky V, Sergeeva E, Kiseleva E, Bagratashvili V. Effects of gamma irradiation on collagen damage and remodeling. Int J Radiat Biol 2015; 91:240-7. [PMID: 25300691 DOI: 10.3109/09553002.2014.969848] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To evaluate the dose-time dependences of structural changes occurring in collagen within 24 hours to three months after gamma-irradiation at doses from 2-40 Gy in vivo. MATERIALS AND METHODS Rat's tail tendon was chosen as in vivo model, with its highly ordered collagen structure allowing the changes to be interpreted unambiguously. Macromolecular level (I) was investigated by differential scanning calorimetry (DSC); fibers and bundles level (II) by laser scanning microscopy (LSM), and bulk tissue microstructural level (III) by cross-polarization optical coherence tomography (CP-OCT). RESULTS For (I), the formation of molecular cross-links and breaks appeared to be a principal mechanism of collagen remodeling, with the cross-links number dependent on radiation dose. Changes on level (II) involved primary, secondary and tertiary bundles splitting in a day and a week after irradiation. Bulk collagen microstructure (III) demonstrated early widening of the interference fringes on CP-OCT images observed to occur in the tendon as result of this splitting. At all three levels, the observed collagen changes demonstrated complete remodeling within ∼ a month following irradiation. CONCLUSION The time course and dose dependencies of the observed collagen changes at different levels of its hierarchy further contribute to elucidating the role of connective tissue in the radiotherapy process.
Collapse
Affiliation(s)
- Anna Maslennikova
- Nizhny Novgorod State Medical Academy , Nizhny Novgorod , Russian Federation
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Heidarkhan Tehrani A, Davari P, Singh S, Oloyede A. Sterilizing tissue-materials using pulsed power plasma. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2014; 25:953-964. [PMID: 24449024 DOI: 10.1007/s10856-014-5142-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2013] [Accepted: 01/09/2014] [Indexed: 06/03/2023]
Abstract
This paper investigates the potential of pulsed power to sterilize hard and soft tissues and its impact on their physico-mechanical properties. It hypothesizes that pulsed plasma can sterilize both vascular and avascular tissues and the transitive layers in between without deleterious effects on their functional characteristics. Cartilage/bone laminate was chosen as a model to demonstrate the concept, treated at low temperature, at atmospheric pressure, in short durations and in buffered environment using a purposed-built pulsed power unit. Input voltage and time of exposure were assigned as controlling parameters in a full factorial design of experiment to determine physical and mechanical alteration pre- and post-treatment. The results demonstrated that, discharges of 11 kV sterilized samples in 45 s, reducing intrinsic elastic modules from 1.4 ± 0.9 to 0.9 ± 0.6 MPa. There was a decrease of 14.1 % in stiffness and 27.8 % in elastic-strain energy for the top quartile. Mechanical impairment was directly proportional to input voltage (P value < 0.05). Bacterial inactivation was proportional to treatment time for input voltages above 32 V (P < 0.001; R Sq = 0.98). Thermal analysis revealed that helix-coil transition decelerated with exposure time and collagen fibrils were destabilized as denaturation enthalpy reduced by 200 μV. We concluded by presenting a safe operating threshold for pulsed power plasma as a feasible protocol for effective sterilization of connective tissues with varying level of loss in mechanical robustness which we argue to be acceptable in certain medical and tissue engineering application.
Collapse
Affiliation(s)
- Ashkan Heidarkhan Tehrani
- Biomechanics Group, School of Chemistry, Physics and Mechanical Engineering, Science and Engineering Faculty, Queensland University of Technology, Brisbane, QLD, 4000, Australia
| | | | | | | |
Collapse
|
10
|
Ignat’eva NY, Zakharkina OL, Kamensky VA, Sergeeva EA, Lunin VV. Thermal and non-thermal effects of nonablative IR laser irradiation of the collagen of annulus fibrosus tissues. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A 2011. [DOI: 10.1134/s0036024411090093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
11
|
Laser-induced modification of the patellar ligament tissue: comparative study of structural and optical changes. Lasers Med Sci 2010; 26:401-13. [PMID: 21190054 PMCID: PMC3069329 DOI: 10.1007/s10103-010-0871-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2010] [Accepted: 11/30/2010] [Indexed: 12/03/2022]
Abstract
The effects of non-ablative infrared (IR) laser treatment of collagenous tissue have been commonly interpreted in terms of collagen denaturation spread over the laser-heated tissue area. In this work, the existing model is refined to account for the recently reported laser-treated tissue heterogeneity and complex collagen degradation pattern using comprehensive optical imaging and calorimetry toolkits. Patella ligament (PL) provided a simple model of type I collagen tissue containing its full structural content from triple-helix molecules to gross architecture. PL ex vivo was subjected to IR laser treatments (laser spot, 1.6 mm) of equal dose, where the tissue temperature reached the collagen denaturation temperature of 60 ± 2°C at the laser spot epicenterin the first regime, and was limited to 67 ± 2°C in the second regime. The collagen network was analyzed versus distance from the epicenter. Experimental characterization of the collagenous tissue at all structural levels included cross-polarization optical coherence tomography, nonlinear optical microscopy, light microscopy/histology, and differential scanning calorimetry. Regressive rearrangement of the PL collagen network was found to spread well outside the laser spot epicenter (>2 mm) and was accompanied by multilevel hierarchical reorganization of collagen. Four zones of distinct optical and morphological properties were identified, all elliptical in shape, and elongated in the direction perpendicular to the PL long axis. Although the collagen transformation into a random-coil molecular structure was occasionally observed, it was mechanical integrity of the supramolecular structures that was primarily compromised. We found that the structural rearrangement of the collagen network related primarily to the heat-induced thermo-mechanical effects rather than molecular unfolding. The current body of evidence supports the notion that the supramolecular collagen structure suffered degradation of various degrees, which gave rise to the observed zonal character of the laser-treated lesion.
Collapse
|
12
|
van Turnhout MC, Kranenbarg S, van Leeuwen JL. Modeling optical behavior of birefringent biological tissues for evaluation of quantitative polarized light microscopy. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:054018. [PMID: 19895120 DOI: 10.1117/1.3241986] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Quantitative polarized light microscopy (qPLM) is a popular tool for the investigation of birefringent architectures in biological tissues. Collagen, the most abundant protein in mammals, is such a birefringent material. Interpretation of results of qPLM in terms of collagen network architecture and anisotropy is challenging, because different collagen networks may yield equal qPLM results. We created a model and used the linear optical behavior of collagen to construct a Jones or Mueller matrix for a histological cartilage section in an optical qPLM train. Histological sections of tendon were used to validate the basic assumption of the model. Results show that information on collagen densities is needed for the interpretation of qPLM results in terms of collagen anisotropy. A parameter that is independent of the optical system and that measures collagen fiber anisotropy is introduced, and its physical interpretation is discussed. With our results, we can quantify which part of different qPLM results is due to differences in collagen densities and which part is due to changes in the collagen network. Because collagen fiber orientation and anisotropy are important for tissue function, these results can improve the biological and medical relevance of qPLM results.
Collapse
Affiliation(s)
- Mark C van Turnhout
- Wageningen University, Department of Animal Sciences, Experimental Zoology Group, P.O. Box 338, Wageningen, 6700 AH, The Netherlands.
| | | | | |
Collapse
|
13
|
Ignatieva N, Zakharkina O, Andreeva I, Sobol E, Kamensky V, Lunin V. Effects of laser irradiation on collagen organization in chemically induced degenerative annulus fibrosus of lumbar intervertebral disc. Lasers Surg Med 2008; 40:422-32. [PMID: 18649381 DOI: 10.1002/lsm.20651] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
BACKGROUND AND OBJECTIVE The number of in vitro experimental studies was carried out with the use of intact tissues to establish a mechanism of laser-tissue interaction. However, in the process of degeneration, both biochemical composition and behavior of the disc were altered drastically. The objective of this study was to evaluate the role of the main matrix components in laser modification of annulus fibrosus (AF) under IR laser irradiation. STUDY DESIGNS/MATERIALS AND METHODS The samples of AF in a motion segment after hyaluronidase treatment, trypsin digestion and glycation by glyceraldehyde were heated in hydrothermal bath (95 degrees C, 2 min) or irradiated by laser at 1.56 microm. Specimens were imaged by cross-polarization optical coherence tomography (CP-OCT), and then analyzed by differential scanning calorimery (DSC). RESULTS AND DISCUSSION According to CP-OCT and DSC data non-significant alteration was revealed in AF after hyaluronidase treatment, glycation led to stabilization of annulus collagen and trypsin digestion resulted in a noticeable impairment of collagen fibrils. Laser treatment induced subsequent damages of AF matrix but these damages cannot be explained by laser heating only. The specificity of chemical modification of AF matrix has an influence on a character of collagen network alteration due to IR laser effect. Minimal and maximal alterations are observed for hyaluronidase and trypsin treated samples respectively. Glyceraldehyde fixed samples showed failure of the collagen structure after moderate laser treatment; at the same time thermal denaturation of collagen macromolecules was negligible. We assume that a mechanical effect of laser irradiation plays an important role in laser-induced annulus collagen modification and propose the scheme of physico-chemical process occurring under non-uniform IR laser treatment in AF tissue. CONCLUSION CP-OCT and DSC techniques allow us to record the alteration of collagen network organization as a result of chemical modification. There were detected significant and specific effects of the biochemical composition and material properties on the response of AF collagen network on laser irradiation. The results go in accordance with our hypothesis that the primary effect of laser influence on collagen network under tension is the mechanical damage of collagen fiber.
Collapse
Affiliation(s)
- Natalia Ignatieva
- Department of Chemistry, M.V. Lomonosov Moscow State University, Moscow, Russia.
| | | | | | | | | | | |
Collapse
|
14
|
Logunova MA, Shakhova MA, Andreeva IV, Ingatieva NY, Kamenskii VA, Bagratiashvili VN. Decreased collagen thermal stability as a response to the loss of structural integrity of thyroid cartilage. Biophysics (Nagoya-shi) 2008. [DOI: 10.1134/s0006350908050266] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
15
|
Hovhannisyan V, Lo W, Hu C, Chen SJ, Dong CY. Dynamics of femtosecond laser photo-modification of collagen fibers. OPTICS EXPRESS 2008; 16:7958-68. [PMID: 18545505 DOI: 10.1364/oe.16.007958] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
In this work, we investigate the non-ablative, non-thermal photo-modification of collagen fibers by femtosecond Ti:Sa laser. The effect was induced and simultaneously registered during the repetitive laser scanning of type I collagen (rat tail and bovine Achilles' tendon), and bovine cornea. An irreversible increase in two-photon autofluorescence and a decrease in second harmonic generation intensities were associated with the collagen femtosecond laser photo-modification. Confocal spectral imaging revealed the formation of new fluorescent species. Controllable nonlinear photo-modification of collagen fibers and bovine cornea with approximately 2 microm spatial resolution was demonstrated.
Collapse
|