Jacobi S, Townsend WM, Bolin CA. Proliferation of Streptococcus zooepidemicus and Pseudomonas aeruginosa within a simulated subpalpebral lavage flushed with equine serum.
Vet Ophthalmol 2009;
12:343-9. [PMID:
19883463 DOI:
10.1111/j.1463-5224.2009.00725.x]
[Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE
To evaluate whether equine serum administered via a simulated subpalpebral lavage system (SPL) supports proliferation of Streptococcus zooepidemicus or Pseudomonas aeruginosa within the tubing.
PROCEDURES
A sterile i.v. catheter with injection cap was inserted into sterilized silicone tubing (Mila). To mimic an SPL within the dorsal conjunctival fornix, the tubing was secured to an elevated platform. The tip of the tubing extended from the platform into a vial containing culture medium just inoculated with approximately 1.5 x 10(8) CFU/mL P. aeruginosa or S. zooepidemicus. To mimic administration of medication, the tubing was infused twice daily with equine serum, sterile saline (negative control), or culture medium (positive control) followed by air. Incubation was at 25 or 37 degrees C. At 24, 48, and 72 h postinoculation, samples were obtained for bacterial culture from one simulated SPL for each experimental variant. The following sections were cultured: (i) tubing tip previously submerged in the inoculated culture medium, (ii) tubing mid-section, and (iii) tip of the i.v. catheter. The experiment was performed in triplicate.
RESULTS
Streptococcus zooepidemicus or P. aeruginosa were isolated from 100% of the tubing tips. Streptococcus zooepidemicus was isolated from one mid-section flushed with culture medium incubated at 37 degrees C. All other samples were negative for growth of the inoculated agents.
CONCLUSIONS
Streptococcus zooepidemicus and P. aeruginosa did not proliferate within silicone tubing infused with equine serum. These data suggest that topical serum can be safely administered through a superiorly placed SPL in clinical cases.
Collapse