Hewetson M, Sykes BW, Hallowell GD, Tulamo RM. Diagnostic accuracy of blood sucrose as a screening test for equine gastric ulcer syndrome (EGUS) in adult horses.
Acta Vet Scand 2017;
59:15. [PMID:
28284214 PMCID:
PMC5346197 DOI:
10.1186/s13028-017-0284-1]
[Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Accepted: 03/05/2017] [Indexed: 12/04/2022] Open
Abstract
Background
Equine gastric ulcer syndrome (EGUS) is common in adult horses, particularly those involved in performance disciplines. Currently, detection of EGUS by gastroscopy is the only reliable ante mortem method for definitive diagnosis; however it is unsuitable as a screening test because it is expensive, time consuming, and is not readily available to most veterinarians. Sucrose permeability testing represents a simple, economical alternative to gastroscopy for screening purposes, and the feasibility of this approach in the horse has been previously reported. The aim of this study was to determine the diagnostic accuracy of blood sucrose as a screening test for EGUS in a large group of adult horses with and without naturally occurring gastric disease.
Results
One hundred and one adult horses with or without naturally occurring gastric ulceration were studied. The diagnostic accuracy of blood sucrose for diagnosis of gastric lesions (GL), glandular lesions (GDL), squamous lesions (SQL), and clinically significant lesions (CSL) at 45 and 90 min after administration of 1 g/kg of sucrose via nasogastric intubation was assessed using receiver operator characteristics (ROC) curves and calculating the area under the curve (AUC). For each lesion type, sucrose concentration in blood was compared to gastroscopy, as the gold standard, and sensitivities (Se) and specificities (Sp) were calculated across a range of sucrose concentrations. Ulcer grading was performed blindly by one observer; and the results were validated by comparing them with that of two other observers, and calculating the level of agreement. Cut-off values were selected manually to optimize Se. The prevalence of GL, GDL, SQL, and CSL was 83, 70, 53 and 58% respectively. At the selected cut-offs, Se ranged from 51 to 79% and Sp ranged from 43 to 72%, depending upon the lesion type and time of sampling.
Conclusions
Blood sucrose is neither a sensitive or specific test for detecting EGUS in this population of adult horses with naturally occurring gastric ulceration. Further studies aimed at evaluating the performance characteristics of the test in different study populations are warranted. Given the limitations of endoscopy, due consideration should also be given to alternative methods for comparison of blood sucrose with a gold standard.
Electronic supplementary material
The online version of this article (doi:10.1186/s13028-017-0284-1) contains supplementary material, which is available to authorized users.
Collapse