Knappe V, Lahrmann C, Funken M, Zietzer A, Gestrich C, Nickenig G, Schrickel JW, Beiert T. Comparison of Arctic Front Advance Pro and POLARx cryoballoons for ablation therapy of atrial fibrillation: an intraprocedural analysis. Clin Res Cardiol 2024:10.1007/s00392-024-02398-2. [PMID: 38358420 DOI: 10.1007/s00392-024-02398-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 02/05/2024] [Indexed: 02/16/2024]
Abstract
INTRODUCTION Cryoballoon (CB) ablation has become a popular method for pulmonary vein isolation (PVI) in atrial fibrillation (AF) treatment. This study aimed to compare the intraprocedural ablation characteristics of two cryoballoons, Arctic Front Advance Pro™ (AFA-Pro, Medtronic) and POLARx™ (Boston Scientific). METHODS AND RESULTS In this retrospective single-center study, 230 symptomatic paroxysmal or persistent AF patients underwent CB ablation with either AFA-Pro or POLARx. Propensity-score matching resulted in two cohorts of 114 patients each. Baseline and procedural characteristics were comparable between both CBs. POLARx achieved lower minimal temperatures (e.g., left superior pulmonary vein, LSPV: AFA-Pro - 49.0 °C vs. POLARx - 59.5 °C) and lower temperatures at time-to-isolation (TTI). Additionally, POLARx reached lower temperatures faster, as evidenced by lower temperatures after 40 and 60 s, and a larger mean temperature change between 20 and 40 s. POLARx also had a greater area under the curve below 0 °C and a longer thawing phase. Both CBs achieved comparable high rates of final PV-isolation. TTI, minimal esophagus temperature, and first-pass isolation rates were similar between groups. Periprocedural complications, including phrenic nerve injuries, were comparable. Troponin levels in the left atrium were elevated with both systems. Values and change in troponin were numerically higher in the POLARx group (delta troponin: AFA-Pro 36.3 (26.4, 125.4) ng/L vs. POLARx 104.9 (49.5, 122.2) ng/L), p = 0.077). CONCLUSION AFA-Pro and POLARx are both highly effective and safe CB systems for PVI. POLARx exhibited significant faster and lower freezing characteristics, and numerically higher troponin levels might indicate greater myocardial injury. However, these differences did not translate into improved performance, procedural efficiency, or safety.
Collapse
Affiliation(s)
- Vincent Knappe
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
| | - Caroline Lahrmann
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Maximilian Funken
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Andreas Zietzer
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Christopher Gestrich
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Georg Nickenig
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Jan W Schrickel
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Thomas Beiert
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| |
Collapse
|
2
|
Yano M, Egami Y, Kawanami S, Ukita K, Kawamura A, Yasumoto K, Tsuda M, Okamoto N, Matsunaga-Lee Y, Nishino M. Ratio of P-Wave Duration to P-Wave Amplitude and Left Atrial Remodeling: Insights from Electrophysiological Findings and Myocardial Injury After Cryoballoon Ablation. Am J Cardiol 2024; 212:109-117. [PMID: 38036050 DOI: 10.1016/j.amjcard.2023.11.046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 10/23/2023] [Accepted: 11/14/2023] [Indexed: 12/02/2023]
Abstract
The impact of the P-wave morphology on clinical outcomes postcatheter ablation (post-CA) and recurrent arrhythmia characteristics or electrophysiologic findings in patients with paroxysmal atrial fibrillation (PAF) remains unclear. Patients with PAF who underwent cryoballoon ablation were enrolled. In 12-lead electrocardiography recorded within 1 month before CA, the P-wave duration (Pd) and P-wave vector magnitude (Pvm) (square root of the sum of the squared P-wave amplitude in leads II, V6, and one-half of the P-wave amplitude in V2) were measured and divided into 2 groups: patients with high and low Pd/Pvm based on a statistically calculated cut-off value. We evaluated the incidence of late recurrence of atrial fibrillation (LRAF), myocardial injury (high-sensitive troponin I), and the electrophysiologic findings in repeat ablation sessions. This study included 269 patients with PAF. The median follow-up duration was 697 days. The cut-off value of the Pd/Pvm for predicting LRAF was 740.7 ms/mV (area under the curve = 0.81, sensitivity = 58.2%, and specificity = 89.6%). Multivariable Cox proportional hazards analysis showed that high Pd/Pvm (>740.7 ms/mV) was significantly associated with LRAF (p <0.001). The high-sensitive troponin I level was significantly lower, and the ratio of DR-FLASH score >3 was significantly higher in those with high than low Pd/Pvm (p = 0.044 and p = 0.002, respectively). In the repeat ablation sessions, the Pd/Pvm in patients with atrial tachycardia-induced or spontaneously occurring during the repeat CA sessions was significantly higher than in those without (p = 0.009). There was a significant difference between the Pd/Pvm and low-voltage area (p <0.001). In conclusion, the Pd/Pvm is significantly associated with LRAF after cryoballoon ablation in patients with PAF and predicts left atrial low-voltage areas and atrial tachycardia inducibility.
Collapse
Affiliation(s)
- Masamichi Yano
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan.
| | - Yasuyuki Egami
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Shodai Kawanami
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Kohei Ukita
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Akito Kawamura
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Koji Yasumoto
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Masaki Tsuda
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Naotaka Okamoto
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | | | - Masami Nishino
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| |
Collapse
|
3
|
Menger V, Frick M, Sharif‐Yakan A, Emrani M, Zink MD, Napp A, Marx N, Gramlich M. Procedural performance between two cryoballoon systems for ablation of atrial fibrillation depends on pulmonary vein anatomy. J Arrhythm 2023. [DOI: 10.1002/joa3.12842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023] Open
Affiliation(s)
- Vincent Menger
- Department of Cardiology University Hospital RWTH Aachen Aachen Germany
| | - Michael Frick
- Department of Cardiology University Hospital RWTH Aachen Aachen Germany
| | | | - Mahdi Emrani
- Department of Cardiology University Hospital RWTH Aachen Aachen Germany
| | | | - Andreas Napp
- Department of Cardiology University Hospital RWTH Aachen Aachen Germany
| | - Nikolaus Marx
- Department of Cardiology University Hospital RWTH Aachen Aachen Germany
| | - Michael Gramlich
- Department of Cardiology University Hospital RWTH Aachen Aachen Germany
| |
Collapse
|
4
|
Best Practice Guide for Cryoballoon Ablation in Atrial Fibrillation: The Compilation Experience of More than 1000 Procedures. J Cardiovasc Dev Dis 2023; 10:jcdd10020055. [PMID: 36826551 PMCID: PMC9967334 DOI: 10.3390/jcdd10020055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 01/23/2023] [Accepted: 01/27/2023] [Indexed: 01/31/2023] Open
Abstract
Nowadays, the cryoballoon (CB) constitutes an established alternative to radio frequency (RF) ablation for pulmonary vein isolation (PVI), which offers the possibility to isolate the PVs with a single application. Since the introduction of the second-generation CB, we prospectively collected our data to optimize the procedure on >1000 consecutive patients who underwent CB PVI performed in our center. It is expected that subsequent guidelines will suggest first-line PVI through CB in patients with paroxysmal AF with a class I indication. Indeed, in the long-term follow-up (36 months) of the EARLY-AF trial, CB had a lower incidence of persistent atrial fibrillation episodes compared to the anti-arrhythmic drugs group. We now review the current best practices in an effort to drive consistent outcomes and minimize complications. PV isolation through CB is the most studied single-shot technique for atrial fibrillation ablation, having shown the potential to alter the natural history of the arrhythmia. Several procedural tips and tricks can improve procedural flow and effectiveness. In the present article we provided not only technical details but measurable biophysical parameters that can reliably guide the operator into achieving the best outcome for his patients.
Collapse
|
5
|
Terasawa M, Chierchia GB, Housari MA, Bala G, Cosyns B, Droogmans S, Tanaka K, Belsack D, De Mey J, Sieira J, Brugada P, de Asmundis C, Ströker E. Predictors of late pulmonary vein reconnection in patients with arrhythmia recurrence after cryoballoon ablation-per vein analysis including cardiac computed tomography-based anatomic factors. Eur Heart J Cardiovasc Imaging 2022:6958487. [PMID: 36562390 DOI: 10.1093/ehjci/jeac255] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 10/27/2022] [Accepted: 12/05/2022] [Indexed: 12/24/2022] Open
Abstract
AIMS To identify predictors of individual late pulmonary vein (PV) reconnection after second-generation cryoballoon (CB2) ablation. Anatomic indicators of late pulmonary vein reconnection (LPVR) post-CB2 ablation have not yet been studied on an individual PV level, nor weighed against clinical and procedural factors. METHODS AND RESULTS Clinical, procedural, and PV anatomic data from 125 patients with a repeat procedure for arrhythmia recurrence after index CB2 ablation were analyzed. Preprocedural computed tomography (CT) evaluated 486 PVs for measurement of size; shape (ovality index); carina width; and orientation angle in frontal (superior/inferior) and transversal (anterior/posterior) plane (with horizontal line 0° as reference and upper/lower half circle as positive/negative value, respectively). Durable isolation in all PVs was demonstrated in 50/125 (40%) patients. Late reconnection rates at the different PVs were as follows: 16% left superior (LS), 12% left inferior (LI), 17% right superior (RS), and 31% right inferior (RI) PV. Multivariable analysis performed per vein showed following independent determinants predicting LPVR: ovality index [odds ratio (OR) 1.61, 95% confidence interval (CI) 1.07-2.41, P = 0.022] and carina width (OR 0.75, CI 0.59-0.96, P = 0.024) for LSPV; carina width (OR 0.71, CI 0.53-0.95, P = 0.020) for LIPV; frontal angle (OR 0.91, CI 0.87-0.95, P < 0.001) for RIPV; and transversal angle (OR 1.15, CI 1.03-1.31, P = 0.032) for RSPV. CONCLUSION Cardiac CT-based evaluation of anatomic PV characteristics presented higher predictive value compared to clinical and procedural variables for individual LPVR after CB2 ablation. Pre-procedural identification of unfavourable PV anatomy might be important to tailor the ablation approach.
Collapse
Affiliation(s)
- Muryo Terasawa
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium.,Department of Cardiology, Tokyo Medical University Hospital, 6-7-1 Nishishinjuku, Shinjuku City, Tokyo 160-0023, Japan
| | - Gian-Battista Chierchia
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Maysam Al Housari
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Bernard Cosyns
- Department of Cardiology, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Steven Droogmans
- Department of Cardiology, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Kaoru Tanaka
- Department of Radiology, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Dries Belsack
- Department of Radiology, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Johan De Mey
- Department of Radiology, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Pedro Brugada
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| | - Erwin Ströker
- Heart Rhythm Management Centre, Postgraduate course in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, 101 Laarbeeklaan, 1090 Brussels, Belgium
| |
Collapse
|
6
|
Yano M, Egami Y, Kawanami S, Sugae H, Ukita K, Kawamura A, Nakamura H, Matsuhiro Y, Yasumoto K, Tsuda M, Okamoto N, Matsunaga-Lee Y, Nishino M, Tanouchi J. Impact of cryoballoon contact angle and acute myocardial injury on pulmonary vein reconnection. Heart Vessels 2022; 37:1882-1891. [PMID: 35552483 DOI: 10.1007/s00380-022-02088-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 04/20/2022] [Indexed: 11/24/2022]
Abstract
At present, it remains unclear whether the effect on cryoinjury can be strongly exerted by contact of the balloon with the pulmonary vein (PV) ostium. The present study included 204 paroxysmal atrial fibrillation (PAF) patients who underwent an initial pulmonary vein isolation (PVI) using a cryoballoon from the Osaka Rosai Atrial Fibrillation ablation (ORAF) registry. The total balloon contact angle was measured from the equator line (sum of the angles of the upper side and bottom side in all PVs) under fluoroscopic imaging. The patients were stratified into three tertile groups according to the total balloon contact angle. We evaluated the relationship between the total balloon contact angle and clinical outcomes, including the value of acute myocardial injury marker (high-sensitive cardiac troponin I [hs-TnI]), arrhythmia recurrence, and PV reconnections in the repeated ablation. The total balloon contact angle was significantly associated with the hs-TnI value among the tertile groups (p < 0.001) and a multiple regression analysis showed that the total balloon contact angle significantly correlated with the hs-TnI value (standardized beta-coefficient = 0.572, p < 0.001). The balloon contact angle in PVs with PV reconnections was significantly lower than in those without (p = 0.044), while no significant differences in the recurrence of atrial fibrillation among the tertile groups were observed in the enrolled patients. The total balloon contact angle was significantly associated with the acute myocardial injury marker, hs-TnI. The total balloon contact angle was significantly associated with PV reconnections after cryoballoon ablation in patients who underwent a repeat ablation.
Collapse
Affiliation(s)
- Masamichi Yano
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Yasuyuki Egami
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Shodai Kawanami
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Hiroki Sugae
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Kohei Ukita
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Akito Kawamura
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Hitoshi Nakamura
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Yutaka Matsuhiro
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Koji Yasumoto
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Masaki Tsuda
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Naotaka Okamoto
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Yasuharu Matsunaga-Lee
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Masami Nishino
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan.
| | - Jun Tanouchi
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, kita-ku, Sakai, Osaka, 591-8025, Japan
| |
Collapse
|
7
|
Mojica J, Lipartiti F, Al Housari M, Bala G, Kazawa S, Miraglia V, Monaco C, Overeinder I, Strazdas A, Ramak R, Paparella G, Sieira J, Capulzini L, Sorgente A, Stroker E, Brugada P, De Asmundis C, Chierchia GB. Procedural Safety and Efficacy for Pulmonary Vein Isolation with the Novel Polarx™ Cryoablation System: A Propensity Score Matched Comparison with the Arctic Front™ Cryoballoon in the Setting of Paroxysmal Atrial Fibrillation. J Atr Fibrillation 2021; 14:20200455. [PMID: 34950358 DOI: 10.4022/jafib.20200455] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 02/12/2021] [Accepted: 06/16/2021] [Indexed: 11/10/2022]
Abstract
Background The novel Polarx™ cryoablation system is currently being studied for atrial fibrillation (AF) ablation. To the best of our knowledge, no study comparing the novel cryoablation system with the standard Arctic Front™ cryoballoon is available in today's literature. This study aims to compare Polarx™ and Arctic Front™ cryoballoon in terms of safety and efficacy. Methods From a total cohort of 202 patients who underwent pulmonary vein (PV) isolation for paroxysmal AF through cryoablation, a population of 30 patients who used Polarx™ were compared with 30 propensity-score matched patients who used Arctic Front™. Results Pulmonary vein occlusion and electrical isolation were achieved in all (100%) veins with a mean number of 1.09 ± 0.3 occlusion per vein using Polarx™ and 1.19 ± 0.5 occlusion per vein using Arctic Front™ (p = 0.6). Shorter procedure and fluoroscopy time were observed with Polarx™ group (60.5 ± 14.23 vs 73.43 ± 13.26 mins, p = 0.001; 12.83 ± 6.03 vs 17.23 ± 7.17 mins, p = 0.01, respectively). Lower cumulative freeze duration per vein was also observed with Polarx™ (203.38 ± 72.03 vs 224.9 ± 79.35 mins, p = 0.02). There was no significant difference in isolation time between the two groups (34.47 ± 21.23 vs 34.18 ± 26.79 secs, p = 0.9). Conclusions The novel Polarx™ cryoablation system showed similar efficacy in vein occlusion and isolation and safety profile when compared to Arctic Front™ cryoablation system. Procedure time, fluoroscopy time, and cumulative freeze duration were significantly lower with Polarx™ cryoablation system.
Collapse
Affiliation(s)
- Joerelle Mojica
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium.,Drs Mojica and Lipartiti contributed equally to the article as first authors
| | - Felicia Lipartiti
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium.,Drs Mojica and Lipartiti contributed equally to the article as first authors
| | - Maysam Al Housari
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Shuichiro Kazawa
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Vincenzo Miraglia
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Cinzia Monaco
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Ingrid Overeinder
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Antanas Strazdas
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Robbert Ramak
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Gaetano Paparella
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Lucio Capulzini
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Erwin Stroker
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Pedro Brugada
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Carlo De Asmundis
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| | - Gian-Battista Chierchia
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel - Brussels, Belgium
| |
Collapse
|
8
|
Yano M, Egami Y, Kawanami S, Sugae H, Ukita K, Kawamura A, Nakamura H, Matsuhiro Y, Yasumoto K, Tsuda M, Okamoto N, Matsunaga-Lee Y, Nishino M, Tanouchi J. Acute myocardial injury after radiofrequency catheter ablation: impact on pulmonary vein reconnection and relevant factors. Heart Vessels 2021; 37:812-820. [PMID: 34668989 DOI: 10.1007/s00380-021-01972-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 10/15/2021] [Indexed: 11/29/2022]
Abstract
Radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) causes myocardial injury and induces high-sensitive cardiac troponin I (hs-TnI) release into the systemic circulation. Several factors are considered to be associated with myocardial injury after ablation, but few studies showed the relationship between the value of myocardial injury marker after the RFCA and relevant factors. AF patients who underwent primary RFCA were enrolled from the Osaka Rosai Atrial Fibrillation ablation (ORAF) registry. The relationship between hs-TnI after the RFCA and PV reconnection (PVR) was evaluated. The impact of relevant factors, including baseline patient characteristics, detail of procedure on myocardial injury was investigated. This study included 407 patients (median age was 71 years, the ratio of female was 30.7%). Late arrhythmia recurrence was observed in 111 patients (27.3%) and 66 patients were underwent repeated ablation. PVR was observed in 33 patients (50.0%). The hs-TnI level was significantly lower in the patients with PVR than those without PVR (1.150 ng/ml vs 1.921 ng/ml, p = 0.040). Paroxysmal AF and age were significantly associated with acute myocardial injury after the RFCA (standardized beta coefficient = 0.206 and p < 0.001, standardized beta coefficient = - 0.114 and p = 0.043, respectively). The hs-TnI after RFCA was significantly higher in PAF patients than PerAF (p < 0.001), even if application number and total application time were taken into consideration. Acute myocardial injury after RFCA was significantly lower in the patients with PVR than those without PVR. Age and AF type were significantly and strongly associated with acute myocardial injury after the RFCA.
Collapse
Affiliation(s)
- Masamichi Yano
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Yasuyuki Egami
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Syodai Kawanami
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Hiroki Sugae
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Kohei Ukita
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Akito Kawamura
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Hitoshi Nakamura
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Yutaka Matsuhiro
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Koji Yasumoto
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Masaki Tsuda
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Naotaka Okamoto
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Yasuharu Matsunaga-Lee
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| | - Masami Nishino
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan.
| | - Jun Tanouchi
- Division of Cardiology, Osaka Rosai Hospital, 3-1179 Nagasonecho, Kita-ku, Sakai, Osaka, 591-8025, Japan
| |
Collapse
|
9
|
Cauti FM, Solimene F, Stabile G, Polselli M, Schillaci V, Arestia A, Shopova G, Iaia L, Giannitti CM, Rossi P, Bianchi S. Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2020; 44:63-70. [DOI: 10.1111/pace.14130] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 10/21/2020] [Accepted: 11/15/2020] [Indexed: 11/29/2022]
Affiliation(s)
- Filippo Maria Cauti
- Arrhythmology Unit, Ospedale San Giovanni Calibita Fatebenefratelli Isola Tiberina Rome Italy
| | | | | | - Marco Polselli
- Arrhythmology Unit, Ospedale San Giovanni Calibita Fatebenefratelli Isola Tiberina Rome Italy
| | | | - Alberto Arestia
- Arrhythmology Unit Clinica Montevergine Mercogliano AV Italy
| | - Gergana Shopova
- Arrhythmology Unit Clinica Montevergine Mercogliano AV Italy
| | - Luigi Iaia
- Arrhythmology Unit Clinica Montevergine Mercogliano AV Italy
| | | | - Pietro Rossi
- Arrhythmology Unit, Ospedale San Giovanni Calibita Fatebenefratelli Isola Tiberina Rome Italy
| | - Stefano Bianchi
- Arrhythmology Unit, Ospedale San Giovanni Calibita Fatebenefratelli Isola Tiberina Rome Italy
| |
Collapse
|
10
|
Mugnai G, de Asmundis C, Chierchia GB. Signal- or temperature-based approach for cryoballoon ablation of atrial fibrillation: still an unsolved issue. J Interv Card Electrophysiol 2020; 59:479-480. [PMID: 32529313 DOI: 10.1007/s10840-020-00792-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 06/01/2020] [Indexed: 11/29/2022]
Affiliation(s)
- Giacomo Mugnai
- Heart Rhythm Management Center, UZ Brussel-VUB, Laarbeeklaan 101, 1090, Brussels, Belgium.
| | - Carlo de Asmundis
- Heart Rhythm Management Center, UZ Brussel-VUB, Laarbeeklaan 101, 1090, Brussels, Belgium
| | | |
Collapse
|