Maciunas K, Snipas M, Kraujalis T, Kraujalienė L, Panfilov AV. The role of the Cx43/Cx45 gap junction voltage gating on wave propagation and arrhythmogenic activity in cardiac tissue. Sci Rep 2023; 13:14863. [PMID: 37684404 PMCID: PMC10491658 DOI: 10.1038/s41598-023-41796-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Accepted: 08/31/2023] [Indexed: 09/10/2023] Open
Abstract
Gap junctions (GJs) formed of connexin (Cx) protein are the main conduits of electrical signals in the heart. Studies indicate that the transitional zone of the atrioventricular (AV) node contains heterotypic Cx43/Cx45 GJ channels which are highly sensitive to transjunctional voltage (Vj). To investigate the putative role of Vj gating of Cx43/Cx45 channels, we performed electrophysiological recordings in cell cultures and developed a novel mathematical/computational model which, for the first time, combines GJ channel Vj gating with a model of membrane excitability to simulate a spread of electrical pulses in 2D. Our simulation and electrophysiological data show that Vj transients during the spread of cardiac excitation can significantly affect the junctional conductance (gj) of Cx43/Cx45 GJs in a direction- and frequency-dependent manner. Subsequent simulation data indicate that such pulse-rate-dependent regulation of gj may have a physiological role in delaying impulse propagation through the AV node. We have also considered the putative role of the Cx43/Cx45 channel gating during pathological impulse propagation. Our simulation data show that Vj gating-induced changes in gj can cause the drift and subsequent termination of spiral waves of excitation. As a result, the development of fibrillation-like processes was significantly reduced in 2D clusters, which contained Vj-sensitive Cx43/Cx45 channels.
Collapse
Affiliation(s)
- Kestutis Maciunas
- Institute of Cardiology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Mindaugas Snipas
- Institute of Cardiology, Lithuanian University of Health Sciences, Kaunas, Lithuania.
- Department of Mathematical Modelling, Kaunas University of Technology, Kaunas, Lithuania.
| | - Tadas Kraujalis
- Institute of Cardiology, Lithuanian University of Health Sciences, Kaunas, Lithuania
- Department of Applied Informatics, Kaunas University of Technology, Kaunas, Lithuania
| | - Lina Kraujalienė
- Institute of Cardiology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Alexander V Panfilov
- Department of Physics and Astronomy, Ghent University, Ghent, Belgium
- Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
2
|
Ravikumar V, Kong X, Tan NY, Christopolous G, Ladas TP, Jiang Z, Tri JA, Sugrue AM, Asirvatham SJ, DeSimone CV, Tolkacheva EG. Complexity analysis of electrical activity during endocardial and epicardial biventricular mapping of ventricular fibrillation. J Interv Card Electrophysiol 2023:10.1007/s10840-023-01606-9. [PMID: 37434040 DOI: 10.1007/s10840-023-01606-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 06/28/2023] [Indexed: 07/13/2023]
Abstract
BACKGROUND Ventricular fibrillation (VF) is a lethal cardiac arrhythmia that is a significant cause of sudden cardiac death. Comprehensive studies of spatiotemporal characteristics of VF in situ are difficult to perform with current mapping systems and catheter technology. OBJECTIVE The goal of this study was to develop a computational approach to characterize VF using a commercially available technology in a large animal model. Prior data suggests that characterization of spatiotemporal organization of electrical activity during VF can be used to provide better mechanistic understanding and potential ablation targets to modify VF and its substrate. We therefore evaluated intracardiac electrograms during biventricular mapping of the endocardium (ENDO) and epicardium (EPI) in acute canine studies. METHODS To develop thresholds for organized and disorganized activity, a linear discriminant analysis (LDA)-based approach was performed to the known organized and disorganized activities recorded in ex vivo Langendorff-perfused rat and rabbit hearts using optical mapping experiments. Several frequency- and time-domain approaches were used as individual and paired features to identify the optimal thresholds for the LDA approach. Subsequently, VF was sequentially mapped in 4 canine hearts, using the CARTO mapping system with a multipolar mapping catheter in the ENDO left and right ventricles and EPI to capture the progression of VF at 3 discrete post-induction time intervals: VF period 1 (just after induction of VF to 15 min), VF period 2 (15 to 30 min), and VF period 3 (30 to 45 min). The developed LDA model, cycle lengths (CL), and regularity indices (RI) were applied to all recorded intracardiac electrograms to quantify the spatiotemporal organization of VF in canine hearts. RESULTS We demonstrated the presence of organized activity in the EPI as VF progresses, in contrary to the ENDO, where the activity stays disorganized. The shortest CL always occurred in the ENDO, especially the RV, indicating a faster VF activity. The highest RI was found in the EPI in all hearts for all VF stages, indicating spatiotemporal consistency of RR intervals. CONCLUSION We identified electrical organization and spatiotemporal differences throughout VF in canine hearts from induction to asystole. Notably, the RV ENDO is characterized by a high level of disorganization and faster VF frequency. In contrast, EPI has a high spatiotemporal organization of VF and consistently long RR intervals.
Collapse
Affiliation(s)
- Vasanth Ravikumar
- Department of Electrical Engineering, University of Minnesota, Minneapolis, USA
| | - Xiangzhen Kong
- Department of Electrical Engineering, University of Minnesota, Minneapolis, USA
| | - Nick Y Tan
- Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | | | - Thomas P Ladas
- Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Zhi Jiang
- Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Jason A Tri
- Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Alan M Sugrue
- Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | | | | | - Elena G Tolkacheva
- Department of Biomedical Engineering, University of Minnesota, 312 Church St SE, Minneapolis, MN, 55455, USA.
- Lillehei Heart Institute, University of Minnesota, Minneapolis, MN, USA.
- Institute for Engineering in Medicine, University of Minnesota, Minneapolis, MN, USA.
| |
Collapse
|
3
|
Kong X, Ravikumar V, Mulpuru SK, Roukoz H, Tolkacheva EG. A Data-Driven Preprocessing Framework for Atrial Fibrillation Intracardiac Electrocardiogram Analysis. ENTROPY (BASEL, SWITZERLAND) 2023; 25:332. [PMID: 36832698 PMCID: PMC9955244 DOI: 10.3390/e25020332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 02/03/2023] [Accepted: 02/09/2023] [Indexed: 06/18/2023]
Abstract
Atrial Fibrillation (AF) is the most common cardiac arrhythmia. Signal-processing approaches are widely used for the analysis of intracardiac electrograms (iEGMs), which are collected during catheter ablation from patients with AF. In order to identify possible targets for ablation therapy, dominant frequency (DF) is widely used and incorporated in electroanatomical mapping systems. Recently, a more robust measure, multiscale frequency (MSF), for iEGM data analysis was adopted and validated. However, before completing any iEGM analysis, a suitable bandpass (BP) filter must be applied to remove noise. Currently, no clear guidelines for BP filter characteristics exist. The lower bound of the BP filter is usually set to 3-5 Hz, while the upper bound (BP¯th) of the BP filter varies from 15 Hz to 50 Hz according to many researchers. This large range of BP¯th subsequently affects the efficiency of further analysis. In this paper, we aimed to develop a data-driven preprocessing framework for iEGM analysis, and validate it based on DF and MSF techniques. To achieve this goal, we optimized the BP¯th using a data-driven approach (DBSCAN clustering) and demonstrated the effects of different BP¯th on subsequent DF and MSF analysis of clinically recorded iEGMs from patients with AF. Our results demonstrated that our preprocessing framework with BP¯th = 15 Hz has the best performance in terms of the highest Dunn index. We further demonstrated that the removal of noisy and contact-loss leads is necessary for performing correct data iEGMs data analysis.
Collapse
Affiliation(s)
- Xiangzhen Kong
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA
| | - Vasanth Ravikumar
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA
| | - Siva K. Mulpuru
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN 55905, USA
| | - Henri Roukoz
- Division of Cardiology, University of Minnesota, Minneapolis, MN 55455, USA
| | - Elena G. Tolkacheva
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455, USA
- Lillehei Heart Institute, University of Minnesota, Minneapolis, MN 55455, USA
- Institute for Engineering in Medicine, University of Minnesota, Minneapolis, MN 55455, USA
| |
Collapse
|
4
|
Shi WR, Wu SH, Zou GC, Xu K, Jiang WF, Zhang Y, Qin M, Liu X. A novel approach for quantitative electrogram analysis for driver identification: Implications for ablation in persistent atrial fibrillation. Front Cardiovasc Med 2022; 9:1049854. [DOI: 10.3389/fcvm.2022.1049854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 11/14/2022] [Indexed: 12/04/2022] Open
Abstract
ObjectiveThis study sought to study the feasibility, efficacy, and safety of using multiscale entropy (MSE) analysis to guide catheter ablation for persistent atrial fibrillation (PsAF) and predict ablation outcomes.MethodsWe prospectively enrolled 108 patients undergoing initial ablation for PsAF. MSE was calculated based on bipolar intracardiac electrograms (iEGMs) to measure the dynamical complexity of biological signals. The iEGMs data were exported after pulmonary vein isolation (PVI), then calculated in a customed platform, and finally re-annotated into the CARTO system. After PVI, regions of the highest mean MSE (mMSE) values were ablated in descending order until AF termination, or three areas had been ablated.ResultsBaseline characteristics were evenly distributed between the AF termination (n = 38, 35.19%) and the non-termination group. The RA-to-LA mean MSE (mMSE) gradient demonstrated a positive gradient in the non-termination group and a negative gradient in the termination group (0.105 ± 0.180 vs. −0.235 ± 0.256, P < 0.001). During a 12-month follow-up, 29 patients (26.9%) had arrhythmia recurrence after single ablation, and 18 of them had AF (62.1%). The termination group had lower rates of arrhythmia recurrence (15.79 vs. 32.86%, Log-Rank P = 0.053) and AF recurrence (10.53 vs. 20%, Log-Rank P = 0.173) after single ablation and a lower rate of arrhythmia recurrence (7.89 vs. 27.14%, Log-Rank P = 0.018) after repeated ablation. Correspondingly, subjects with negative RA-to-LA mMSE gradient had lower incidences of arrhythmia (16.67 vs. 35%, Log-Rank P = 0.028) and AF (16.67 vs. 35%, Log-Rank P = 0.032) recurrence after single ablation and arrhythmia recurrence after repeated ablation (12.5 vs. 26.67%, Log-Rank P = 0.062). Marginal peri-procedural safety outcomes were observed.ConclusionMSE analysis-guided driver ablation in addition to PVI for PsAF could be feasible, efficient, and safe. An RA < LA mMSE gradient before ablation could predict freedom from arrhythmia. The RA-LA MSE gradient could be useful for guiding ablation strategy selection.
Collapse
|
5
|
Bai J, Lu Y, Wang H, Zhao J. How synergy between mechanistic and statistical models is impacting research in atrial fibrillation. Front Physiol 2022; 13:957604. [PMID: 36111152 PMCID: PMC9468674 DOI: 10.3389/fphys.2022.957604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 08/08/2022] [Indexed: 11/13/2022] Open
Abstract
Atrial fibrillation (AF) with multiple complications, high morbidity and mortality, and low cure rates, has become a global public health problem. Although significant progress has been made in the treatment methods represented by anti-AF drugs and radiofrequency ablation, the therapeutic effect is not as good as expected. The reason is mainly because of our lack of understanding of AF mechanisms. This field has benefited from mechanistic and (or) statistical methodologies. Recent renewed interest in digital twin techniques by synergizing between mechanistic and statistical models has opened new frontiers in AF analysis. In the review, we briefly present findings that gave rise to the AF pathophysiology and current therapeutic modalities. We then summarize the achievements of digital twin technologies in three aspects: understanding AF mechanisms, screening anti-AF drugs and optimizing ablation strategies. Finally, we discuss the challenges that hinder the clinical application of the digital twin heart. With the rapid progress in data reuse and sharing, we expect their application to realize the transition from AF description to response prediction.
Collapse
Affiliation(s)
- Jieyun Bai
- Guangdong Provincial Key Laboratory of Traditional Chinese Medicine Information Technology, Jinan University, Guangzhou, China
- College of Information Science and Technology, Jinan University, Guangzhou, China
- *Correspondence: Jieyun Bai, ; Jichao Zhao,
| | - Yaosheng Lu
- Guangdong Provincial Key Laboratory of Traditional Chinese Medicine Information Technology, Jinan University, Guangzhou, China
- College of Information Science and Technology, Jinan University, Guangzhou, China
| | - Huijin Wang
- College of Information Science and Technology, Jinan University, Guangzhou, China
| | - Jichao Zhao
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
- *Correspondence: Jieyun Bai, ; Jichao Zhao,
| |
Collapse
|
6
|
Ravikumar V, Thakare S, Kong X, Roukoz H, Tolkacheva EG. Similarity Score for the Identification of Active Sites in Patients With Atrial Fibrillation. Front Physiol 2022; 12:767190. [PMID: 35126172 PMCID: PMC8811172 DOI: 10.3389/fphys.2021.767190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 11/24/2021] [Indexed: 11/16/2022] Open
Abstract
Background Atrial fibrillation (AF) is the most common cardiac arrhythmia and precursor to other cardiac diseases. Catheter ablation is associated with limited success rates in patients with persistent AF. Currently, existing mapping systems fail to identify critical target sites for ablation. Recently, we proposed and validated several individual techniques, such as dominant frequency (DF), multiscale frequency (MSF), kurtosis (Kt), and multiscale entropy (MSE), to identify active sites of arrhythmias using simulated intracardiac electrograms (iEGMs). However, the individual performances of these techniques to identify arrhythmogenic substrates are not reliable. Objective This study aimed to develop a similarity score using various iEGM analysis techniques to more accurately identify the spatial location of active sites of arrhythmia in patients with AF. Methods Clinical bipolar iEGMs were obtained from patients with AF who underwent either successful (m = 4) or unsuccessful (m = 4) catheter ablation. A similarity score (0–3) was developed via the earth mover’s distance (EMD) approach based on a combination of DF, MSF, MSE, and Kt techniques. Results Individual techniques successfully discriminated between successful and unsuccessful AF ablation patients but were not reliable in identifying active spatial sites of AF. However, the proposed similarity score was able to pinpoint the spatial sites with high values (active AF sites) that were observed only in patients with unsuccessful AF termination, suggesting that these active sites were missed during the ablation procedure. Conclusion Arrhythmogenic substrates with abnormal electrical activity are identified in patients with unsuccessful AF termination after catheter ablation, suggesting clinical efficacy of similarity score.
Collapse
Affiliation(s)
- Vasanth Ravikumar
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Sanket Thakare
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Xiangzhen Kong
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Henri Roukoz
- Division of Cardiology, Department of Medicine, University of Minnesota, Minneapolis, MN, United States
| | - Elena G. Tolkacheva
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States
- *Correspondence: Elena G. Tolkacheva,
| |
Collapse
|
7
|
Bartolucci C, Fabbri C, Tomasi C, Sabbatani P, Severi S, Corsi C. Computational Analysis of Mapping Catheter Geometry and Contact Quality Effects on Rotor Detection in Atrial Fibrillation. Front Physiol 2021; 12:732161. [PMID: 34955872 PMCID: PMC8696082 DOI: 10.3389/fphys.2021.732161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 11/18/2021] [Indexed: 11/30/2022] Open
Abstract
Atrial fibrillation (AF) is the most common cardiac arrhythmia and catheter mapping has been proved to be an effective approach for detecting AF drivers to be targeted by ablation. Among drivers, the so-called rotors have gained the most attention: their identification and spatial location could help to understand which patient-specific mechanisms are acting, and thus to guide the ablation execution. Since rotor detection by multi-electrode catheters may be influenced by several structural parameters including inter-electrode spacing, catheter coverage, and endocardium-catheter distance, in this study we proposed a tool for testing the ability of different catheter shapes to detect rotors in different conditions. An approach based on the solution of the monodomain equations coupled with a modified Courtemanche ionic atrial model, that considers an electrical remodeling, was applied to simulate spiral wave dynamics on a 2D model for 7.75 s. The developed framework allowed the acquisition of unipolar signals at 2 KHz. Two high-density multipolar catheters were simulated (Advisor™ HD Grid and PentaRay®) and placed in a 2D region in which the simulated spiral wave persists longer. The configuration of the catheters was then modified by changing the number of electrodes, inter-electrodes distance, position, and atrial-wall distance for assessing how they would affect the rotor detection. In contact with the wall and at 1 mm distance from it, all the configurations detected the rotor correctly, irrespective of geometry, coverage, and inter-electrode distance. In the HDGrid-like geometry, the increase of the inter-electrode distance from 3 to 6 mm caused rotor detection failure at 2 mm distance from the LA wall. In the PentaRay-like configuration, regardless of inter-electrode distance, rotor detection failed at 3 mm endocardium-catheter distance. The asymmetry of this catheter resulted in rotation-dependent rotor detection. To conclude, the computational framework we developed is based on realistic catheter shapes designed with parameter configurations which resemble clinical settings. Results showed it is well suited to investigate how mapping catheter geometry and location affect AF driver detection, therefore it is a reliable tool to design and test new mapping catheters.
Collapse
Affiliation(s)
- Chiara Bartolucci
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| | - Claudio Fabbri
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| | - Corrado Tomasi
- Electrophysiology Laboratory, Cardiology Unit, Ravenna and Cesena Hospitals, Azienda Unità Sanitaria Locale della Romagna, Ravenna, Italy
| | - Paolo Sabbatani
- Electrophysiology Laboratory, Cardiology Unit, Ravenna and Cesena Hospitals, Azienda Unità Sanitaria Locale della Romagna, Ravenna, Italy
| | - Stefano Severi
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| | - Cristiana Corsi
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| |
Collapse
|