1
|
Kohli U, von Alvensleben J, Srinivasan C. Subcutaneous Implantable Cardioverter Defibrillators in Pediatrics and Congenital Heart Disease. Card Electrophysiol Clin 2023; 15:e1-e16. [PMID: 38030336 DOI: 10.1016/j.ccep.2023.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023]
Abstract
Subcutaneous implantable cardioverter defibrillators (S-ICDs) are being used with increased frequency in children and patients with congenital heart disease. Vascular access complexities, intracardiac shunts, and specific anatomies make these devices particularly appealing for some of these patients. Alternative screening, implantation, and programming techniques should be considered based on patient size, body habitus, anatomy, procedural history, and preference. Appropriate and inappropriate shock rates are generally comparable to those seen with transvenous devices. Complications such as infection can occur, although their severity is likely to be less than that seen with transvenous devices. Technical advances are likely to further broaden S-ICD applicability.
Collapse
Affiliation(s)
- Utkarsh Kohli
- Division of Pediatric Cardiology, Department of Pediatrics, West Virginia University School of Medicine and West Virginia University Children's Heart Center, 64 Medical Center Drive, Robert C. Byrd Health Science Center, PO Box 9214, Morgantown, WV 26506-9214, USA.
| | - Johannes von Alvensleben
- Children's Hospital Colorado, University of Colorado School of Medicine, 13123 East 16th Avenue, Aurora, CO 80045 720-777-1234, USA
| | - Chandra Srinivasan
- The Children's Hospital of Philadelphia; University of Perelman School of Medicine, 3401 Civic Center Boulevard, Philadelphia, PA 19104, USA
| |
Collapse
|
2
|
Migliore F, Pittorru R, Giacomin E, Dall'Aglio PB, Falzone PV, Bertaglia E, Iliceto S, Gregori D, De Lazzari M, Corrado D. Intermuscular two-incision technique for implantation of the subcutaneous implantable cardioverter defibrillator: a 3-year follow-up. J Interv Card Electrophysiol 2023:10.1007/s10840-023-01478-z. [PMID: 36662384 DOI: 10.1007/s10840-023-01478-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 01/10/2023] [Indexed: 01/21/2023]
Abstract
PURPOSE The aim of the present study was to evaluate the outcome of patients underwent subcutaneous implantable cardioverter defibrillator (S-ICD) implantation with the intermuscular (IM) two-incision technique during 3-year follow-up. METHODS the study population consisted of 105 consecutive patients (79 male; median 50 [13-77] years) underwent S-ICD implantation with the IM two-incision technique. The composite primary end point of the study consisted of device-related complications and inappropriate shocks (IAS). Secondary end points included the individual components of the primary end point, death from any cause, appropriate therapy, major adverse cardiac events, hospitalization for heart failure, and heart transplantation. RESULTS According to the PRAETORIAN score, the risk of conversion failure was classified as low in 99 patients (94.3%), intermediate in 6 (5.7%).Ventricular fibrillation was successfully converted at ≤65 J in 97.4% of patients. During a median follow-up of 39 (16-53) months, 10 patients (9.5%) experienced device-related complications, and 9 (8.5%) patients reported IAS. Lead-associated complications were the most common (5 patients, 4.7%), including 2 cases of lead failure (1.9%). Pocket complications were reported in 2 patients (1.9%). Extra-cardiac oversensing (3.8%) represented the leading cause of IAS. No T-wave oversensing episodes were recorded. Twelve patients (11.4%) experienced appropriate shocks. Eight patients (7.6%) died during follow-up. IAS or device-related complications did not impact on mortality. CONCLUSIONS The overall device-related complications and IAS rates over 3 years of follow-up were 9.5% and 8.5%, respectively. According to our findings, the IM two-incision technique allows for optimal positioning of the device achieving a low PRAETORIAN score with a high conversion rate. IM two-incision technique allows low incidence of pocket complications, shifting the type of complications towards lead-related complications, which represent the most common complications. The IM two-incision technique would not seem to impact the occurrence of IAS. Management of complications are safe without impact on the outcome.
Collapse
Affiliation(s)
- Federico Migliore
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy.
| | - Raimondo Pittorru
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| | - Enrico Giacomin
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| | - Pietro Bernardo Dall'Aglio
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| | - Pasquale Valerio Falzone
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| | - Emanuele Bertaglia
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| | - Sabino Iliceto
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| | - Dario Gregori
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
- Statistics, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padova, Italy
| | - Manuel De Lazzari
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| | - Domenico Corrado
- Cardiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Via Giustiniani 2, 35121, Padova, Italy
| |
Collapse
|
3
|
Innovations in atrial fibrillation ablation. J Interv Card Electrophysiol 2022; 66:737-756. [PMID: 35411440 DOI: 10.1007/s10840-022-01215-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 04/05/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND Catheter-based ablation to perform pulmonary vein isolation (PVI) has established itself as a mainstay in the rhythm control strategy of atrial fibrillation. This review article aims to provide an overview of recent advances in atrial fibrillation ablation technology. METHODS We reviewed the available literature and clinical trials of innovations in atrial fibrillation ablation technologies including ablation catheter designs, alternative energy sources, esophageal protection methods, electroanatomical mapping, and novel ablation targets. RESULTS Innovative radiofrequency (RF) catheter designs maximize energy delivery while avoiding overheating associated with conventional catheters. Single-shot balloon catheters in the form of cryoballoons, radiofrequency, and laser balloons have proven effective at producing pulmonary vein isolation and improving procedural efficiency and reproducibility. Pulsed field ablation (PFA) is a highly anticipated novel nonthermal energy source under development, which demonstrates selective ablation of the myocardium, producing durable lesions while also minimizing collateral damage. Innovative devices for esophageal protection including esophageal deviation and cooling devices have been developed to reduce esophageal complications. Improved electroanatomical mapping systems are being developed to help identify additional non-pulmonary triggers, which may benefit from ablation, especially with persistent atrial fibrillation. Lastly, the vein of Marshall alcohol ablation has been recently studied as an adjunct therapy for improving outcomes with catheter ablation for persistent atrial fibrillation. CONCLUSIONS Numerous advances have been made in the field of atrial fibrillation ablation in the past decade. While further long-term data is still needed for these novel technologies, they show potential to improve procedural efficacy and safety.
Collapse
|
4
|
Vanneman M, Kothari P, Bodmer NJ, Convissar D, Desai GA, Kumar N, Iyer MH, Neuburger PJ, Essandoh MK, Cronin B, Dalia AA. The Year in Electrophysiology: Selected Highlights from 2021. J Cardiothorac Vasc Anesth 2022; 36:1526-1539. [DOI: 10.1053/j.jvca.2022.01.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 01/28/2022] [Indexed: 11/11/2022]
|