1
|
Aswal GS, Rawat R, Dwivedi D, Prabhakar N, Kumar V. Clinical Outcomes of CAD/CAM (Lithium disilicate and Zirconia) Based and Conventional Full Crowns and Fixed Partial Dentures: A Systematic Review and Meta-Analysis. Cureus 2023; 15:e37888. [PMID: 37213959 PMCID: PMC10199723 DOI: 10.7759/cureus.37888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/14/2023] [Indexed: 05/23/2023] Open
Abstract
Although CAD/CAM (computer-aided design/computer-aided manufacturing) restorations act as a favorable alternative to conventional metal-ceramic restorations for fixed dental prostheses, little is known about their intermediate and persistent clinical performance. This systematic review and meta-analysis aimed to assess the clinical performance in terms of biological, technical, and esthetic aspects and the survival and success ratios for single full crowns (SFCs) and fixed partial dentures (FPDs) fabricated by CAD/CAM and conventional techniques and according to the materials used (zirconia {ZC} and lithium disilicate {LD}). The population, intervention, control, outcome, and study design (PICOS) strategy was used to electronically search key terms in the PubMed, Cochrane Library, Embase, and Wiley Online databases for randomized control trials (RCTs) and cohort studies. The bias risks for RCTs and cohort studies were assessed using the Cochrane collaboration tool and the Newcastle-Ottawa Scale (NOS). Meta-analysis was performed using Rev5 from Cochrane. A total of 13 studies reporting on 1598 restorations in 1161 patients with a mean observation period of 3.6 years (minimum-maximum: 1-9.3 years) met the inclusion criteria. Meta-analysis of the included studies indicated that CAD/CAM manufacturing resulted in 1.17, 1.14, and 16.88 (95% CI: 0.64-2.17, 0.86-1.52, 7.59-37.56) higher biological, technical, and esthetic complications than conventional manufacturing of restorations. However, the difference was significant for esthetic complications only (p<0.00001). A significant difference was observed for all biological, technical, and aesthetic aspects between SFCs and FPDs (odds ratio {OR} = 2.61 vs. 1.78, 95% CI: 1.92-3.56 vs. 1.33-2.38; p<0.00001). The survival ratio of SFCs was 2.69 (95% CI: 1.98-3.65), significantly higher compared to the 1.76 (95% CI: 1.31-2.36) of FPDs (p<0.00001). The success ratio of FPDs at 1.18 (95% CI: 0.83-1.69) was significantly lower compared to SFCs at 2.36 (95% CI: 1.68-3.33). The clinical performance of LD with 2.42 (CI: 1.16-5.03) was significantly higher compared to ZC with 2.22 (CI: 1.78-2.77) (p<0.00001). The biological, technical, and aesthetic behaviors showed similar clinical outcomes between the CAD/CAM and conventional groups. LD could be a good alternative to zirconia, but its intermediate or persistent clinical performance needs to be evaluated. Overall, zirconia and CAD/CAM techniques must evolve further to outclass the conventional techniques used in the fabrication of SFCs and FPDs.
Collapse
Affiliation(s)
- Gunjan S Aswal
- Dentistry, The University of the West Indies, St. Augustine, TTO
| | - Renu Rawat
- Dentistry, The University of the West Indies, St. Augustine, TTO
| | | | | | | |
Collapse
|
2
|
Ribeiro RF, Oliveira DF, Tovani CB, Ramos AP, Borges AFS, Faria ACL, de Almeida RP, Rodrigues RCS. Y-TZP Physicochemical Properties Conditioned with ZrO 2 and SiO 2 Nanofilms and Bond Strength to Dual Resin Cement. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7905. [PMID: 36431390 PMCID: PMC9694964 DOI: 10.3390/ma15227905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/24/2022] [Accepted: 11/07/2022] [Indexed: 06/16/2023]
Abstract
Commercial Yttria-tetragonal zirconia polycrystalline (Y-TZP) was subjected to surface treatments, and the bond strength of dual resin cement to Y-TZP and failure modes were evaluated. Disks (12 mm × 2 mm), cylinders (7 mm × 3.3 mm), and bars (25 mm × 5 mm × 2 mm) were milled from Y-TZP CAD-CAM blocks, divided into seven groups, and subjected to different surface treatments; silicatization was used as control. On the basis of the literature, this study evaluated modifications with films containing SiO2 nanoparticles and silane; SiO2+ZrO2—SiO2 (50%) and ZrO2 (50%) nanoparticles, SiO2+ZrO2/Silane-SiO2 (50%) and ZrO2 (50%) nanoparticles, and silane. Specimens were analyzed by wettability (n = 3), surface free energy (n = 3), X-ray diffraction (n = 1), Fourier transform infrared spectroscopy (FTIR) (n = 1), roughness (n = 5), shear bond test (n = 10), and dynamic modulus (n = 3). Specimens treated with hydrofluoric acid—HF 40% presented significantly higher contact angle and lowest surface free energy (p < 0.05). The SiO2/Silane presented crystalline SiO2 on the surface. The surface roughness was significantly higher for groups treated with nanofilms (p < 0.05). Shear bond strength was significantly higher for silicatization, HF 40%/silicatization, SiO2/Silane, and SiO2+ZrO2/Silane groups. The proposed treatments with nanofilms had potentially good results without prejudice to the physicochemical characteristics of zirconia. Generally, groups that underwent silica surface deposition and silanization had better bond strength (p < 0.005).
Collapse
Affiliation(s)
- Ricardo Faria Ribeiro
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Danilo Flamini Oliveira
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Camila Bussola Tovani
- Department of Chemistry, Faculty of Philosophy, Sciences and Letters at Ribeirao Preto, University of Sao Paulo-FFCLRP-USP, Ribeirao Preto 14040-901, SP, Brazil
| | - Ana Paula Ramos
- Department of Chemistry, Faculty of Philosophy, Sciences and Letters at Ribeirao Preto, University of Sao Paulo-FFCLRP-USP, Ribeirao Preto 14040-901, SP, Brazil
| | - Ana Flavia Sanches Borges
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo-FOB/USP, Bauru 17012-901, SP, Brazil
| | - Adriana Claudia Lapria Faria
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Rossana Pereira de Almeida
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Renata Cristina Silveira Rodrigues
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| |
Collapse
|
3
|
Laumbacher H, Strasser T, Knüttel H, Rosentritt M. Long-term clinical performance and complications of zirconia-based tooth- and implant-supported fixed prosthodontic restorations: A summary of systematic reviews. J Dent 2021; 111:103723. [PMID: 34119611 DOI: 10.1016/j.jdent.2021.103723] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 05/21/2021] [Accepted: 06/02/2021] [Indexed: 01/08/2023] Open
Abstract
OBJECTIVES To present an overview on systematic reviews on prosthodontic zirconia restorations and to discuss long-term complications as well as information on anatomical and functional changes to the masticatory system. DATA/SOURCES MEDLINE, EMBASE, Trip medical, and Cochrane Library databases were searched for systematic reviews up to February 2021. Bias was assessed and clinical survival and complications were analyzed. STUDY SELECTION 38 eligible articles published between 2006 and 2021 were included. The reviews were based on 128 in vivo studies on approximately 10,000 zirconia restorations. 5-year cumulative survival rates varied between 91.2% and 95.9% for tooth-supported (TS) single crowns (SC), 89.4% and 100% for TS multi-unit fixed dental prostheses (FDP), 97.1% and 97.6% for implant-supported (IS) SCs and 93.0% and 100% for IS FDPs. Chipping was the most often technical complication, followed by framework fracture, loss of retention, marginal discrepancies/discoloration, occlusal roughness and abutment/screw loosening. Color mismatch was the only esthetic complication. Biological complications were caries, endodontic complications, tooth fracture, periodontal disease, abrasion/attrition, persisting pain, high sensitivity, peri‑implantitis and soft tissue issues. Patients with bruxism were only examined sporadically. CONCLUSIONS 5-year results for zirconia restorations were satisfactory. The predominant technical problem of veneering fractures could be overcome with adapted design or fabrication and application of monolithic restorations, but reviews of clinical studies on this subject are rare. The impact of zirconia restorations on the masticatory system remains unclear. CLINICAL SIGNIFICANCE Zirconia restorations are experiencing a rapidly increasing use in dental practice. Being highly wear-resistant, hard and durable, it can be assumed that they do not follow natural abrasion and changes in the masticatory system. Possible long-term effects on the stomatognathic system as a whole should therefore be considered.
Collapse
Affiliation(s)
- Harald Laumbacher
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany
| | - Thomas Strasser
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany
| | - Helge Knüttel
- University Library, University of Regensburg, 93042 Regensburg, Germany
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany.
| |
Collapse
|
4
|
Fatigue behaviour of dental crowns made from a novel high-performance polymer PEKK. Clin Oral Investig 2021; 25:4895-4905. [PMID: 33506428 PMCID: PMC8342378 DOI: 10.1007/s00784-021-03797-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 01/13/2021] [Indexed: 11/11/2022]
Abstract
Objectives The aim of this study was, firstly, to analyse the long-time fatigue behaviour of crowns constructed from a novel polyetherketoneketone (PEKK) polymer, using artificial prepared teeth. Secondly, to determine the effect of the material’s stiffness that used as an artificial prepared tooth on the fatigue life of the PEKK crowns in comparison to human prepared teeth. Methods Veneered crowns with a PEKK framework were constructed on three different prepared teeth: artificial polymethyl methacrylate (PMMA) teeth, artificial CoCr teeth and extracted human teeth. As far as applicable, the loading protocol was based on EN ISO 14801:2007 for fatigue testing of dental implants. After initial static fracture tests on three specimens from each group, the remaining crowns were loaded with different force levels until fracture or until 2 × 106 loading cycles were reached. The number of loading cycles until failure was recorded. Wöhler curves were created to display the fatigue limits. Results Static fracture limits as well as fatigue limits differed for all three core materials. The static fracture tests resulted in fracture limits of 1200 (± 293) N for the PMMA group, 1330 (± 219) N for the CoCr group and 899 (± 96) N for the human tooth group. Fatigue limits of 770 N, 840 N and 720 N were determined for the PMMA group, CoCr group and human tooth group, respectively. Conclusions The determined fatigue limit of above 720 N (depending on the core material) is sufficiently high and a good performance of this crown material is expected in the clinical loading life. The results showed that using artificial teeth instead of natural teeth for fatigue testing of crowns might result in an overestimation of the fatigue limits of the crown material. Clinical relevance PEKK-made crowns offer a stable and priceworthy treatment for patients, in particular those that suffer from metal allergy.
Collapse
|
5
|
Rosentritt M, Preis V, Behr M, Strasser T. Fatigue and wear behaviour of zirconia materials. J Mech Behav Biomed Mater 2020; 110:103970. [DOI: 10.1016/j.jmbbm.2020.103970] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 06/29/2020] [Accepted: 07/01/2020] [Indexed: 01/10/2023]
|
6
|
AL‐Rabab'ah MA, AlTarawneh S, Jarad FD, Devlin H. Methodological Quality of Systematic Reviews Relating to Performance of All‐Ceramic Implant Abutments, Frameworks, and Restorations. J Prosthodont 2020; 30:36-46. [DOI: 10.1111/jopr.13206] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 05/26/2020] [Accepted: 05/27/2020] [Indexed: 01/07/2023] Open
Affiliation(s)
- Mohammad A. AL‐Rabab'ah
- Department of Conservative Dentistry, School of Dentistry The University of Jordan Amman Jordan
- School of Dentistry University of Liverpool UK
- Division of Dentistry The University of Manchester UK
| | - Sandra AlTarawneh
- Department of Removable Prosthodontics, School of Dentistry The University of Jordan Amman Jordan
- Department of Restorative Dentistry UIC College of Dentistry Chicago IL
| | | | - Hugh Devlin
- Division of Dentistry The University of Manchester UK
| |
Collapse
|
7
|
Fiorin L, Moris ICM, Faria ACL, Ribeiro RF, Rodrigues RCS. Effect of different grinding protocols on surface characteristics and fatigue behavior of yttria-stabilized zirconia polycrystalline: An in vitro study. J Prosthet Dent 2020; 124:486.e1-486.e8. [PMID: 32446636 DOI: 10.1016/j.prosdent.2020.03.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 03/10/2020] [Accepted: 03/11/2020] [Indexed: 11/17/2022]
Abstract
STATEMENT OF PROBLEM Zirconia frameworks milled by computer-aided design and computer-aided manufacturing (CAD-CAM) often require clinical adjustments. In addition, zirconia prefabricated abutments can also require customization to achieve an adequate emergence profile. However, the influence of grinding adjustment on the surface characteristics and mechanical behavior of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and the best grinding protocol is unclear. PURPOSE The purpose of this in vitro study was to evaluate the effect of different grinding protocols on the surface characteristics, phase transformation, and mechanical behavior of Y-TZP for frameworks and implant abutments. MATERIAL AND METHODS Bar-shaped specimens were fabricated according to ISO 6872-2016 and divided into 3 groups: GC (control, untreated), GA (grinding and finishing with medium and fine diamond rotary instruments using high-speed handpiece under constant water cooling), and GB (grinding and finishing with coarse and medium diamond rotary instruments, respectively, using slow-speed handpiece without water cooling). After specimen grinding, the topography and surface roughness were evaluated by using a laser confocal microscope, the Young modulus was measured by the impulse excitation technique, and crystallographic phase transformation was analyzed by X-ray diffraction. Specimens were then submitted to step-stress accelerated life testing (n=18). The surface roughness and Young modulus results were analyzed by 1-way ANOVA and the Tukey honestly significant difference test (α=.05). The data of step-stress accelerated life testing were analyzed by the survival probability considering the number of cycles and force until fracture. RESULTS Statistically significant differences were found among groups considering surface roughness (GA>GB>GC) (P<.05) and Young modulus (GB>GA=GC) (P=.003). X-ray diffraction showed that grinding leads to phase transformation, GC showed only tetragonal phase, while GA and GB showed tetragonal and monoclinic phases. No statistically significant difference (P<.05) was found among groups submitted to the same loading profile when the survival probability was compared, but significant difference was found between the light and moderate loading (P=.002) and light and severe loading (P=.014) of GB when different loading profiles in each group were compared. CONCLUSIONS Although grinding protocols affected surface characteristics and promoted phase transformation, the mechanical behavior of Y-TZP was not impaired. Therefore, both the grinding protocols tested can be safely used based on the evaluated properties.
Collapse
Affiliation(s)
- Lívia Fiorin
- Graduate student, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Izabela C M Moris
- Former graduate, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Adriana C L Faria
- Laboratory specialist, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Ricardo F Ribeiro
- Professor, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Renata C S Rodrigues
- Professor, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
| |
Collapse
|
8
|
Habibi Y, Dawid M, Waldecker M, Rammelsberg P, Bömicke W. Three‐year clinical performance of monolithic and partially veneered zirconia ceramic fixed partial dentures. J ESTHET RESTOR DENT 2020; 32:395-402. [DOI: 10.1111/jerd.12568] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Accepted: 01/16/2020] [Indexed: 12/14/2022]
Affiliation(s)
- Yasamin Habibi
- Department of Prosthetic DentistryUniversity Hospital Heidelberg, University of Heidelberg Heidelberg Germany
| | - Marie‐Theres Dawid
- Department of Prosthetic DentistryUniversity Hospital Heidelberg, University of Heidelberg Heidelberg Germany
| | - Moritz Waldecker
- Department of Prosthetic DentistryUniversity Hospital Heidelberg, University of Heidelberg Heidelberg Germany
| | - Peter Rammelsberg
- Department of Prosthetic DentistryUniversity Hospital Heidelberg, University of Heidelberg Heidelberg Germany
| | - Wolfgang Bömicke
- Department of Prosthetic DentistryUniversity Hospital Heidelberg, University of Heidelberg Heidelberg Germany
| |
Collapse
|
9
|
Rodrigues SB, Franken P, Celeste RK, Leitune VCB, Collares FM. CAD/CAM or conventional ceramic materials restorations longevity: a systematic review and meta-analysis. J Prosthodont Res 2019; 63:389-395. [PMID: 31303569 DOI: 10.1016/j.jpor.2018.11.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 10/23/2018] [Accepted: 11/09/2018] [Indexed: 11/17/2022]
Abstract
PURPOSE This systematic review and meta-analysis aimed to evaluate the difference in longevity of tooth-supported ceramic prostheses designed by conventional and computer-aided design/computer-aided manufacturing (CAD/CAM) techniques. STUDY SELECTION Two reviewers searched the Web of Science, PubMed, SCOPUS and LILACS databases between 1966 and October 2017. Clinical studies that compared the survival rate of CAD/CAM against conventional restorations were included. RESULTS Eleven randomized controlled trials and three prospective studies were included, n=14. Three types of tooth-supported restorations were searched in the included studies: single crown, multiple-unit and partial ceramic crown. The follow-up of patients in the studies ranged from 24 to 84 months. A total of 1209 restorations had been placed in 957 patients in the included trials, and failures were analyzed by type and material restoration. From a total of 72 restoration failures, the CAD/CAM system resulted in a 1.84 (IC95%: 1.28-2.63) higher risk than conventional manufacturing of ceramic restoration. Nevertheless, when drop-outs were included as a failure risk, the CAD/CAM system resulted in a risk of 1.32 (IC95%: 1.10-1.58). Multilevel analysis of tooth-supported ceramic restorations, considering drop-outs as successes, resulted in rates of 1.48 and 2.62 failures per 100 restoration-years for the controls and CAD/CAM groups, respectively. Considering drop-outs as failures, we found rates of 4.23 and 5.88 failures per 100 restoration-years for the controls and CAD/CAM groups, respectively. CONCLUSIONS The meta-analysis results suggest that the longevity of a tooth-supported ceramic prostheses made by CAD/CAM manufacturing is lower than that of crowns mad by the conventional technique.
Collapse
Affiliation(s)
- Stéfani Becker Rodrigues
- Department of Conservative Dentistry, Dental Materials Laboratory, School of Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Brazil
| | - Patrícia Franken
- Department of Conservative Dentistry, Dental Materials Laboratory, School of Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Brazil
| | - Roger Keller Celeste
- Department of Preventive and Social Dentistry, School of Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Brazil
| | - Vicente Castelo Branco Leitune
- Department of Conservative Dentistry, Dental Materials Laboratory, School of Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Brazil
| | - Fabrício Mezzomo Collares
- Department of Conservative Dentistry, Dental Materials Laboratory, School of Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Brazil.
| |
Collapse
|
10
|
Dal Piva AMDO, Tribst JPM, Borges ALS, de Melo RM, Bottino MA. Influence of substrate design for in vitro mechanical testing. J Clin Exp Dent 2019; 11:e119-e125. [PMID: 30805115 PMCID: PMC6383903 DOI: 10.4317/jced.55353] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Accepted: 01/14/2019] [Indexed: 12/16/2022] Open
Abstract
Background The goal of this study was to evaluate the influence of dental substrate simulator material, and the presence of root and periodontal ligament on the stress distribution in an adhesively-cemented monolithic crown. Material and Methods Five (5) 3D models according to the substrate simulator material and shape were modeled with CAD software for conducting non-linear finite element analysis (FEA): Tooth with and without periodontal ligament - subgroup "pl" (groups Tooth+pl and Tooth-pl), machined tooth in epoxy-resin with and without pulp chamber - subgroup "pc" (ER+pc and ER-pc) and simplified epoxy-resin substrate without pulp chamber and roots (SiER). Next, adhesively-cemented monolithic crowns in zirconia reinforced lithium silicate were modeled over each substrate. The solids were then imported in STEP format to the analysis software and the contact between teeth and cylinder was considered perfectly bonded; whereas, the contacts involving the resin cement were considered as non-separated. The materials were considered isotropic, linearly elastic, and homogeneous. An axial load (600 N) was applied to the occlusal surface and results of maximum principal stress (MPa) on the restoration were required. Results FEA revealed that all evaluated subtracts showed the crown intaglio surface as the most stressed region. The average stress and stress peaks were similar for restorations cemented onto Tooth+pl, Tooth-pl and ER+pc substrates, but, 13% higher in comparison to ER-pc and SiER substrates. Conclusions Simplified substrates can be used to evaluate posterior full crown behavior without periodontal ligaments and roots, since the rigidity of the specimen is taken into account. Key words:Finite element analysis, axial loading, computed assisted numerical analisys, monolithic crowns,methodological study.
Collapse
Affiliation(s)
- Amanda-Maria-de Oliveira Dal Piva
- DDs, MSc, PhD Student, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000. Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081 LA Amsterdam, Noord-Holland, The Netherlands
| | - João-Paulo-Mendes Tribst
- DDs, MSc, PhD Student, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000. Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081 LA Amsterdam, Noord-Holland, The Netherlands
| | - Alexandre-Luiz-Souto Borges
- DDs, MSc, PhD, Adjunct Professor, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000
| | - Renata-Marques de Melo
- DDs, MSc, PhD, Researcher III, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000
| | - Marco-Antonio Bottino
- DDs, MSc, PhD, Professor, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000
| |
Collapse
|
11
|
Efficacy of photobiomodulation on accelerating bone healing after tooth extraction: a systematic review. Lasers Med Sci 2018; 34:685-692. [DOI: 10.1007/s10103-018-2641-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2018] [Accepted: 09/14/2018] [Indexed: 12/18/2022]
|
12
|
Elshiyab SH, Nawafleh N, Walsh L, George R. Fracture resistance and survival of implant-supported, zirconia-based hybrid-abutment crowns: Influence of aging and crown structure. ACTA ACUST UNITED AC 2018; 9:e12355. [PMID: 30105895 DOI: 10.1111/jicd.12355] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Accepted: 05/18/2018] [Indexed: 11/29/2022]
Abstract
AIM The aim of the present study was to investigate fracture resistance of implant-supported zirconia-based crowns (monolayer vs bilayer) cemented to hybrid abutments. METHODS Monolayer and bilayer zirconia crowns were constructed and cemented to zirconia hybrid abutments. Crowns were divided into two subgroups: (a) untreated control group; and (b) experimental group, which underwent thermal-cycling mechanical loading in a chewing simulator. Up to 1.2 million stress cycles with simultaneous thermocycling (5 and 55°C) were applied. Samples were finally subjected to static load to fracture. Data were analyzed using one-way analysis of variance and t test. Fractured surfaces were observed using scanning electron microscopy. RESULTS Monolayer zirconia crowns had a 100% survival rate upon completion of the thermal mechanical loading, whereas bilayer zirconia crowns had a 50% survival rate. The fracture load of monolayer zirconia crowns was significantly higher than that of bilayer crowns. Moreover, the fracture load was significantly reduced in monolayer zirconia crowns after aging. Monolayer zirconia crowns showed bulk fracture within the monolayer, while bilayer crowns exhibited cohesive fracture within the veneering porcelain only. CONCLUSIONS Monolayer implant-supported hybrid-abutment crowns exhibit significantly higher fracture resistance compared to bilayer crowns, making them better suited to handle higher masticatory loads encountered in the posterior region of the mouth.
Collapse
Affiliation(s)
- Shareen H Elshiyab
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Australia.,Department of Applied Dental Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Noor Nawafleh
- Department of Applied Dental Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Laurence Walsh
- School of Dentistry, University of Queensland, Brisbane, Australia
| | - Roy George
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Australia
| |
Collapse
|