1
|
Khattab SY, Hijaz BA, Semenov YR. Cutaneous Imaging Techniques. Hematol Oncol Clin North Am 2024; 38:907-919. [PMID: 39079790 DOI: 10.1016/j.hoc.2024.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/03/2024]
Abstract
Cutaneous imaging is a central tenant to the practice of dermatology. In this article, the authors explore various noninvasive and invasive skin imaging techniques, as well as the latest deployment of these technologies in conjunction with the use artificial intelligence and machine learning. The authors also provide insight into the benefits, limitations, and challenges around integrating these technologies into dermatologic practice.
Collapse
Affiliation(s)
- Sara Yasmin Khattab
- Department of Dermatology, Massachusetts General Hospital, 40 Blossom Street, Bartlett Hall 6R, Room 626, Boston, MA 02114, USA
| | - Baraa Ashraf Hijaz
- Department of Dermatology, Massachusetts General Hospital, 40 Blossom Street, Bartlett Hall 6R, Room 626, Boston, MA 02114, USA; Harvard Medical School, Boston, MA 02115, USA
| | - Yevgeniy Romanovich Semenov
- Department of Dermatology, Massachusetts General Hospital, 40 Blossom Street, Bartlett Hall 6R, Room 626, Boston, MA 02114, USA; Harvard Medical School, Boston, MA 02115, USA.
| |
Collapse
|
2
|
da Silva Barbosa J, de Melo NB, Firmino RT, Arruda MJALLA, Ferreira JEV, Amorim AMAM, de Melo DP, Bento PM. Influence of sex, age and ethnicity on the facial temperature. Arch Dermatol Res 2024; 316:520. [PMID: 39136790 DOI: 10.1007/s00403-024-03266-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2024] [Revised: 07/16/2024] [Accepted: 07/30/2024] [Indexed: 10/25/2024]
Affiliation(s)
- Jussara da Silva Barbosa
- Department of Dentistry, State University of Paraíba - Graduate Program in Dentistry, Rua Baraúnas, 351 - Bairro Universitário, Campina Grande, PB, CEP 58429-500, Brazil.
| | - Niebla Bezerra de Melo
- University Center Maurício de Nassau (UNINASSAU), R. Antônio Carvalho de Souza, 295 - Estação Velha, Campina Grande, PB, 58410-050, Brazil
| | - Ramon Targino Firmino
- Biological Sciences Academic Unit, Federal University of Campina Grande, Patos, Paraíba, 58700-970, Brazil
| | | | - José Eraldo Viana Ferreira
- University Center UNIFACISA, R. Manoel Cardoso Palhano, 124-152 - Itararé, Campina Grande, PB, 58408-326, Brazil
| | - Ana Marly Araújo Maia Amorim
- Department of Dentistry, State University of Paraíba - Graduate Program in Dentistry, Rua Baraúnas, 351 - Bairro Universitário, Campina Grande, PB, CEP 58429-500, Brazil
| | - Daniela Pita de Melo
- College of Dentistry, University of Saskatchewan, Saskatoon, SK, S7N 5E5, Canada
| | - Patrícia Meira Bento
- Department of Dentistry, State University of Paraíba - Graduate Program in Dentistry, Rua Baraúnas, 351 - Bairro Universitário, Campina Grande, PB, CEP 58429-500, Brazil
| |
Collapse
|
3
|
Nicolas-Rodriguez E, Pons-Fuster E, López-Jornet P. Diagnostic Infrared Thermography of the Tongue and Taste Perception in Patients with Oral Lichen Planus: Case-Control Study. J Clin Med 2024; 13:435. [PMID: 38256569 PMCID: PMC10816281 DOI: 10.3390/jcm13020435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 12/31/2023] [Accepted: 01/10/2024] [Indexed: 01/24/2024] Open
Abstract
Oral lichen planus (OLP) is a chronic inflammatory disease of autoimmune origin that affects the skin and mucous membranes. The aim of this study was to assess the effectiveness of infrared thermography (IRT) as a diagnostic tool in patients with oral lichen planus (OLP), as well as disturbances in taste perception, in cases with and without tongue involvement. A case-control study was carried out in a sample of 87 patients divided into three groups: healthy individuals (controls; n = 43), OLP patients without involvement of the tongue (n = 24), and OLP patients with involvement of the tongue (n = 20). The patient symptoms and the clinical characteristics of the lesions were assessed. Four thermal images of the tongue were obtained using IRT: dorsum, right and left lateral surface, and tip of the tongue. General taste perception capacity and subjective sweet, acid, salty, and bitter sensation were evaluated in all three groups. There were no statistically significant differences in the IRT values among the three groups (p ≥ 0.05). In the OLP patients with involvement of the tongue, significantly higher values were observed in the mixed forms of the disease (p = 0.032). The OLP patients with and without involvement of the tongue showed no significant alterations in taste sensation (p = 0.69). IRT may serve as a complementary tool for assessing the activity of OLP with involvement of the tongue. However, more research is needed in this field.
Collapse
Affiliation(s)
- Elena Nicolas-Rodriguez
- Faculty of Medicine and Odontology, Hospital Morales Meseguer, Clínica Odontológica, Marqués del Los Vélez s/n, 30008 Murcia, Spain;
| | - Eduardo Pons-Fuster
- Departamento de Anatomía Humana y Psicobiología, Faculty of Medicine and Odontology, Biomedical Research Institute (IMIB-Arrixaca), University of Murcia Spain, 30100 Murcia, Spain;
| | - Pia López-Jornet
- Faculty of Medicine and Odontology, Hospital Morales Meseguer, Clínica Odontológica, Marqués del Los Vélez s/n, 30008 Murcia, Spain;
| |
Collapse
|
4
|
Kesztyüs D, Brucher S, Wilson C, Kesztyüs T. Use of Infrared Thermography in Medical Diagnosis, Screening, and Disease Monitoring: A Scoping Review. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:2139. [PMID: 38138242 PMCID: PMC10744680 DOI: 10.3390/medicina59122139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/06/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023]
Abstract
Thermography provides non-invasive, radiation-free diagnostic imaging. Despite the extensive literature on medical thermography, a comprehensive overview of current applications is lacking. Hence, the aim of this scoping review is to identify the medical applications of passive infrared thermography and to catalogue the technical and environmental modalities. The diagnostic performance of thermography and the existence of specific reference data are evaluated, and research gaps and future tasks identified. The entire review process followed the Joanna Briggs Institute (JBI) approach and the results are reported according to PRISMA-ScR guidelines. The scoping review protocol is registered at the Open Science Framework (OSF). PubMed, CENTRAL, Embase, Web of Science, OpenGrey, OSF, and PROSPERO were searched using pretested search strategies based on the Population, Concept, Context (PCC) approach. According to the eligibility criteria, references were screened by two researchers independently. Seventy-two research articles were identified describing screening, diagnostic, or monitoring studies investigating the potential of thermography in a total of 17,314 participants within 38 different health conditions across 13 therapeutic areas. The use of several camera models from various manufacturers is described. These and other facts and figures are compiled and presented in a detailed, descriptive tabular and visual format. Thermography offers promising diagnostic capabilities, alone or in addition to conventional methods.
Collapse
Affiliation(s)
- Dorothea Kesztyüs
- Medical Data Integration Centre, Department of Medical Informatics, University Medical Centre, Georg-August University Göttingen, 37073 Göttingen, Germany; (C.W.); (T.K.)
| | - Sabrina Brucher
- Institute for Distance Learning, Technical University of Applied Sciences, 13353 Berlin, Germany
| | - Carolyn Wilson
- Medical Data Integration Centre, Department of Medical Informatics, University Medical Centre, Georg-August University Göttingen, 37073 Göttingen, Germany; (C.W.); (T.K.)
| | - Tibor Kesztyüs
- Medical Data Integration Centre, Department of Medical Informatics, University Medical Centre, Georg-August University Göttingen, 37073 Göttingen, Germany; (C.W.); (T.K.)
- Institute for Distance Learning, Technical University of Applied Sciences, 13353 Berlin, Germany
| |
Collapse
|
5
|
López Sanz P, García Vázquez A, Gómez Sánchez ME, Escario Travesedo E. How We Do It: The Role of Infrared Thermography as a Supportive Technique in the Treatment of Hyperhidrosis. Dermatol Surg 2023; 49:1048-1049. [PMID: 37606642 DOI: 10.1097/dss.0000000000003910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/23/2023]
Affiliation(s)
- Pablo López Sanz
- Department of Dermatology, Hospital General Universitario de Albacete, Castilla-La Mancha, Spain
| | | | | | | |
Collapse
|
6
|
Mazdeyasna S, Ghassemi P, Wang Q. Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy. SENSORS (BASEL, SWITZERLAND) 2023; 23:8011. [PMID: 37766064 PMCID: PMC10536210 DOI: 10.3390/s23188011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/12/2023] [Accepted: 09/15/2023] [Indexed: 09/29/2023]
Abstract
Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0-75°), ETRS set temperature (TETRS, 30-40 °C), ambient temperature (Tatm, 18-32 °C), relative humidity (RH, 15-80%), and working distance (d, 0.4-2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of Tatm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal TETRS for EBT detection was 36-37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (TCS) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2-3.0 m, Tatm of 15-35 °C, and RH of 5-95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.
Collapse
Affiliation(s)
| | | | - Quanzeng Wang
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA; (S.M.); (P.G.)
| |
Collapse
|