1
|
Piayda K, Bertog S, Mbai M, Sharma A, Veulemans V, Sievert H. Practical Aspects of Patent Foramen Ovale Closure: Ultrasound and Fluoroscopic Guidance. Cardiol Clin 2024; 42:537-545. [PMID: 39322344 DOI: 10.1016/j.ccl.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/27/2024]
Abstract
Percutaneous PFO closure is a well-established medical procedure to mitigate paradoxic embolism and the future risk of stroke in a well-selected patient clientele. When it comes to procedural guidance during PFO closure, various modalities exist, each with its own advantages and disadvantages. Guidance by transesophageal echocardiography (in combination with fluoroscopy) offers high-resolution 2D/3D imaging, however, it requires the presence of a peri-interventional imager and conscious sedation (or endotracheal intubation). Intracardiac echocardiography and fluoroscopy guidance can be performed by a single operator and omits the need for conscious sedation (or endotracheal intubation).
Collapse
Affiliation(s)
- Kerstin Piayda
- Cardiovascular Center Frankfurt, Frankfurt, Germany; Department of Cardiology and Vascular Medicine, University Hospital Gießen and Marburg, Gießen, Germany
| | - Stefan Bertog
- Cardiovascular Center Frankfurt, Frankfurt, Germany; Minneapolis Veterans Affairs Medical Center, Minneapolis, MN, USA
| | - Mackenzie Mbai
- Minneapolis Veterans Affairs Medical Center, Minneapolis, MN, USA
| | - Alok Sharma
- Minneapolis Veterans Affairs Medical Center, Minneapolis, MN, USA
| | - Verena Veulemans
- Department of Cardiology, Pneumology and Vascular Medicine, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Horst Sievert
- Cardiovascular Center Frankfurt, Frankfurt, Germany.
| |
Collapse
|
2
|
Devos P, Guedeney P, Montalescot G. Patent Foramen Ovale Percutaneous Closure: Evolution and Ongoing Challenges. J Clin Med 2023; 13:54. [PMID: 38202061 PMCID: PMC10780039 DOI: 10.3390/jcm13010054] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/28/2023] [Accepted: 12/15/2023] [Indexed: 01/12/2024] Open
Abstract
Patent foramen ovale (PFO) concerns nearly a quarter of the general population and incidence may reach up to 50% in patients with cryptogenic stroke. Recent randomized clinical trials confirmed that percutaneous closure of PFO-related stroke reduces the risk of embolic event recurrence. PFO also comes into play in other pathogenic conditions, such as migraine, decompression sickness or platypnea-orthodeoxia syndrome, where the heterogeneity of patients is high and evidence for closure is less well-documented. In this review, we describe the current indications for PFO percutaneous closure and the remaining challenges, and try to provide future directions regarding the technique and its indications.
Collapse
Affiliation(s)
- Perrine Devos
- ACTION Study Group, INSERM UMRS_1166 Institut de Cardiologie (AP-HP), Sorbonne Université, 75005 Paris, France; (P.D.); (P.G.)
| | - Paul Guedeney
- ACTION Study Group, INSERM UMRS_1166 Institut de Cardiologie (AP-HP), Sorbonne Université, 75005 Paris, France; (P.D.); (P.G.)
| | - Gilles Montalescot
- ACTION Study Group, INSERM UMRS_1166 Institut de Cardiologie (AP-HP), Sorbonne Université, 75005 Paris, France; (P.D.); (P.G.)
- Institut de Cardiologie, Centre Hospitalier Universitaire, Pitié-Salpêtrière, 47 Boulevard de l’Hôpital, 75013 Paris, France
| |
Collapse
|
3
|
Verolino G, Calderone D, Gavazzoni M, Sala D, Sganzerla P. Clinical Performance of the Gore Septal Occluder in Patent Foramen Ovale Closure in Different Septal Anatomies: 1-Year Results from a Single-Center Experience. J Clin Med 2023; 12:5936. [PMID: 37762877 PMCID: PMC10531839 DOI: 10.3390/jcm12185936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 08/21/2023] [Accepted: 09/06/2023] [Indexed: 09/29/2023] Open
Abstract
BACKGROUND PFO (Patent foramen ovale) is a common defect that affects about 25% of the population. Although its presence is asymptomatic in the majority of the cases, the remaining part becomes overt with different symptoms, including cryptogenic stroke. PFO closure is currently a widely available procedure in complex anatomy, with Amplatzer PFO Occluder (APO) being the most commonly used tool. However, the performance of another device, the GORE Septal Occluder (GSO), has not been completely explored with regard to different septal anatomies. METHODS From March 2012 to June 2020, 118 consecutive patients with an indication of PFO closure were treated using the GSO system, included in a prospective analysis, and followed. After 12 months, every patient underwent transcranial Doppler ultrasound to evaluate the effectiveness of treatment. RESULTS Of 111 patients evaluated, 107 showed effective PFO closure (96.4%), and 4 showed a residual shunt (3.6%). To better evaluate the device performance, the overall population was sorted into two clusters based on the echocardiographic characteristics. The main difference between groups was for PFO width (4.85 ± 1.8 vs. 2.9 ± 1 mm, p < 0.001) and PFO tunnel length (12.6 ± 3.8 vs. 7.2 ± 2, p < 0.001), allowing complex and simple anatomies to be identified, respectively. Regardless of the aforementioned cluster, the GSO performance required to reach an effective closure was independent of anatomy type and the chosen device size. CONCLUSION The GSO device showed a high closure rate at 1-year follow-up in patients, with at least one anatomical factor of complexity of PFO irrespective of the level of complexity itself.
Collapse
Affiliation(s)
- Giuseppe Verolino
- Invasive Cardiology, Department of Cardiology, San Luca Hospital, IRCCS Istituto Auxologico Italiano, 20149 Milan, Italy; (G.V.); (P.S.)
| | - Dario Calderone
- Invasive Cardiology, Department of Cardiology, San Luca Hospital, IRCCS Istituto Auxologico Italiano, 20149 Milan, Italy; (G.V.); (P.S.)
| | - Mara Gavazzoni
- Cardiology Unit, San Luca Hospital, IRCCS Istituto Auxologico Italiano, 20149 Milan, Italy
| | - Davide Sala
- Invasive Cardiology, Department of Cardiology, San Luca Hospital, IRCCS Istituto Auxologico Italiano, 20149 Milan, Italy; (G.V.); (P.S.)
| | - Paolo Sganzerla
- Invasive Cardiology, Department of Cardiology, San Luca Hospital, IRCCS Istituto Auxologico Italiano, 20149 Milan, Italy; (G.V.); (P.S.)
| |
Collapse
|
4
|
Lucà F, Pino PG, Parrini I, Di Fusco SA, Ceravolo R, Madeo A, Leone A, La Mair M, Benedetto FA, Riccio C, Oliva F, Colivicchi F, Gulizia MM, Gelsomino S. Patent Foramen Ovale and Cryptogenic Stroke: Integrated Management. J Clin Med 2023; 12:1952. [PMID: 36902748 PMCID: PMC10004032 DOI: 10.3390/jcm12051952] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 02/13/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023] Open
Abstract
Patent foramen ovale (PFO) is a common cardiac abnormality with a prevalence of 25% in the general population. PFO has been associated with the paradoxical embolism causing cryptogenic stroke and systemic embolization. Results from clinical trials, meta-analyses, and position papers support percutaneous PFO device closure (PPFOC), especially if interatrial septal aneurysms coexist and in the presence of large shunts in young patients. Remarkably, accurately evaluating patients to refer to the closure strategy is extremely important. However, the selection of patients for PFO closure is still not so clear. The aim of this review is to update and clarify which patients should be considered for closure treatment.
Collapse
Affiliation(s)
- Fabiana Lucà
- Cardiology Department, Grande Ospedale Metropolitano, GOM, AO Bianchi Melacrino Morelli, 89129 Reggio di Calabria, Italy
| | - Paolo G. Pino
- Cardiology Department, San Camillo Forlanini Hospital, 00152 Rome, Italy
| | - Iris Parrini
- Cardiology Department, Mauriziano Hospital, 10128 Torino, Italy
| | - Stefania Angela Di Fusco
- Clinical and Rehabilitation Cardiology Department, San Filippo Neri Hospital, ASL Roma 1, 00135 Roma, Italy
| | - Roberto Ceravolo
- Cardiology Unit, Giovanni Paolo II Hospital, 88046 Lamezia, Italy
| | | | - Angelo Leone
- Ospedale Santissima Annunziata, 87100 Cosenza, Italy
| | - Mark La Mair
- Cardiothoracic Department, Brussels University Hospital, 1090 Jette, Belgium
| | - Francesco Antonio Benedetto
- Cardiology Department, Grande Ospedale Metropolitano, GOM, AO Bianchi Melacrino Morelli, 89129 Reggio di Calabria, Italy
| | - Carmine Riccio
- Division of Clinical Cardiology, A.O.R.N. ‘Sant’Anna e San Sebastiano’, 81100 Caserta, Italy
| | - Fabrizio Oliva
- De Gasperis Cardio Center, Niguarda Hospital, 20162 Milano, Italy
| | - Furio Colivicchi
- Clinical and Rehabilitation Cardiology Department, San Filippo Neri Hospital, ASL Roma 1, 00135 Roma, Italy
| | | | - Sandro Gelsomino
- Cardiothoracic Department, Maastricht University, 6211 LK Maastrich, The Netherlands
| |
Collapse
|
5
|
Hutayanon P, Muengtaweepongsa S. The Role of Transcranial Doppler in Detecting Patent Foramen Ovale. JOURNAL FOR VASCULAR ULTRASOUND 2023; 47:33-39. [DOI: 10.1177/15443167221108512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/03/2023]
Abstract
Air embolic signals detected in the intracranial arteries using transcranial Doppler after intravenous injection of agitated saline bubbles indicate right-to-left cardiac shunting. They prove that emboli from venous sites can bypass the lungs and flow to the intracranial arteries. The Valsalva maneuver immediately after an intravenous injection of agitated saline bubbles helps the air bubbles pass through the shunt. If the air embolic signal appears in the intracranial arteries without the Valsalva maneuver, the shunting is highly significant to the etiology of embolism. Transcranial Doppler to detect air embolic signals after intravenous injection of agitated saline bubbles may not be mandatory to diagnose and treat patent foramen ovale; however, as with echocardiography, transcranial Doppler is considered a noninvasive, convenient, and low-cost investigation. The test should be helpful to confirm the significance of the corresponding patent foramen ovale.
Collapse
|
6
|
Abrahamyan L, Barker M, Dharma C, Lee DS, Austin PC, Asghar A, Muthuppalaniappan A, Benson L, Osten M, Horlick EM. Real world long-term outcomes among adults undergoing transcatheter patent foramen closure with amplatzer PFO occluder. Int J Cardiol 2023; 371:109-115. [PMID: 36165815 DOI: 10.1016/j.ijcard.2022.09.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 08/22/2022] [Accepted: 09/15/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND Patent foramen ovale (PFO) is a congenital heart defect associated with an increased risk of cryptogenic stroke. We aimed to evaluate real-world outcomes of adult patients undergoing transcatheter PFO closure with the Amplatzer PFO Occluder. METHODS In this single centre, retrospective cohort study, we linked a detailed clinical registry with provincial administrative databases to obtain short and long-term outcomes. Validated algorithms were used to established baseline comorbidities and adverse outcomes. RESULTS Between 1999 and 2017, 479 patients had PFO closure with an Amplatzer PFO Occluder. The average age of the patients was 47.3 years (standard deviation (SD) = 12.4), and 54.7% were males. The procedural success was 100%, and 96% of patients were discharged on the same day. Any in-hospital complication was observed in 2.5% (n = 12) of patients. At 30 days post-discharge, 18% of patients had an ED visit and 5% a hospitalization. Over a mean follow-up of 9.1 (SD = 3.8) years, 4% experienced TIA, 1.5% stroke, and 7.6% atrial fibrillation. The composite outcome of stroke/TIA/death was observed in 10.9% of patients (1.22 events per 100 person-years). Patients >60 years old experienced higher rates of adverse events than younger patients. CONCLUSIONS In this large real-world cohort of patients with cryptogenic stroke, we observed excellent safety and effectiveness outcomes for PFO closure conducted with Amplatzer PFO Occluder, similar to randomized controlled trials or other long-term cohort studies. New onset atrial fibrillation was one of the most commonly adverse events. Future studies should investigate early post-discharge management of patients to prevent readmissions.
Collapse
Affiliation(s)
- Lusine Abrahamyan
- Toronto General Hospital Research Institute, University Health Network (UHN), Toronto, ON, Canada; Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, ON, Canada
| | - Madeleine Barker
- Center for Cardiovascular Innovation - Centre d'Innovation Cardiovasculaire (CCI-CIC), University of British Columbia, Vancouver, BC, Canada
| | | | - Douglas S Lee
- ICES, Toronto, ON, Canada; Division of Cardiology, Peter Munk Cardiac Centre, UHN, Toronto, ON, Canada
| | - Peter C Austin
- Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, ON, Canada; ICES, Toronto, ON, Canada
| | - Areeba Asghar
- Toronto General Hospital Research Institute, University Health Network (UHN), Toronto, ON, Canada; McMaster University, Hamilton, ON, Canada
| | | | - Lee Benson
- The Labatt Family Heart Centre, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Mark Osten
- Toronto Congenital Cardiac Centre for Adults, Peter Munk Cardiac Centre, UHN, Toronto, ON, Canada
| | - Eric M Horlick
- Toronto Congenital Cardiac Centre for Adults, Peter Munk Cardiac Centre, UHN, Toronto, ON, Canada.
| |
Collapse
|
7
|
D'Andrea A, Dweck MR, Holte E, Fontes-Carvalho R, Cameli M, Aboumarie HS, Diener HC, Haugaa KH. EACVI survey on the management of patients with patent foramen ovale and cryptogenic stroke. Eur Heart J Cardiovasc Imaging 2021; 22:135-141. [PMID: 33346351 PMCID: PMC7822641 DOI: 10.1093/ehjci/jeaa318] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 11/05/2020] [Indexed: 11/14/2022] Open
Abstract
AIMS The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey to evaluate the current practice for the assessment and management of patients with suspected patent foramen ovale (PFO) and cryptogenic stroke. METHODS AND RESULTS In total, 79 imaging centres from 34 countries across the world responded to the survey, which comprised 17 questions. Most non-invasive investigations for PFO were widely available in the responding centres, with the exception of transcranial colour Doppler which was only available in 70% of sites, and most commonly performed by neurologists. Standard transthoracic echocardiography, with or without bubbles, was considered the first-level test for suspected PFO in the majority of the centres, whereas transoesophageal echocardiography was an excellent second-level modality. Most centres would rule out atrial fibrillation (AF) as a source of embolism in all patients with cryptogenic stroke (63%), with the remainder reserving investigation for patients with multiple AF risk factors (33%). Cardiac magnetic resonance was the preferred tool for identifying other unusual aetiologies, like cardiac masses or thrombi. After PFO closure, there was variation in the use of antiplatelet therapy: a quarter recommended treatment for life, while only 12% recommended 5 years as stipulated in the guidelines (12%). Antibiotic prophylaxis prior to dental or endoscopic procedures was not recommended in 41% of centres, contrary to what the guidelines recommended. CONCLUSION Our survey revealed a variable adherence to the current recommendations for the diagnosis and management of patients with cryptogenic stroke and PFO. Efforts should focus on optimizing and standardizing diagnostic tests and treatment of this condition.
Collapse
Affiliation(s)
- Antonello D'Andrea
- Department of Cardiology, Umberto I_ Hospital, Luigi Vanvitelli University - Nocera Inferiore (ASL Salerno), Viale San Francesco - 84014 Caserta, Italy
| | - Marc R Dweck
- BHF Centre for Cardiovascular Science, Department of Cardiology, University of Edinburgh, Edinburgh, EH16 4SB, UK
| | - Espen Holte
- Department of Cardiology, St. Olavs Hospital, Postboks 3250 Torgarden, 7006 Trondheim, Norway
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology NTNU, Trondheim, PO Box 8905, 7491 Trondheim, Norway
| | - Ricardo Fontes-Carvalho
- Cardiovascular Research and Development Unit, Department of Physiology and Cardiothoracic Surgery, Faculty of Medicine, University of Porto, Al. Prof. Hernâni Monteiro, 4200-319 Porto, Portugal
| | - Matteo Cameli
- Department of Cardiovascular Diseases, University of Siena, Policlinico Le Scotte, Viale Bracci 16, 53100 Siena, Italy
| | - Hatem Soliman Aboumarie
- Department of Cardiology - Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, UB9 6JH London, UK
| | - Hans Christoph Diener
- Department of Neurology - Medical Faculty of the University Duisburg-Essen—Institute for Medical Informatics, Biometry and Epidemiology, Hufelandstraße, 26, 45147 Essen, Germany
| | - Kristina H Haugaa
- Department of Cardiology, Oslo University Hospital, Postboks 4950 Nydalen, 0424 Oslo, Norway
- Department of Cardiology - Institute for Clinical Medicine, University of Oslo, Postboks 1171 Blindern, 0318 Oslo, Norway
| |
Collapse
|
8
|
Demulier L, Paelinck BP, Coomans I, Hemelsoet D, De Backer J, Campens L, De Wolf D. A new dimension in patent foramen ovale size estimation. Echocardiography 2020; 37:1049-1055. [PMID: 32634292 DOI: 10.1111/echo.14696] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Accepted: 04/27/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Detailed multidimensional assessment of patent foramen ovale (PFO) size with transesophageal echocardiography (TOE) may help to determine PFO pathogenicity in cryptogenic stroke patients. We explored the potential additive value of Live xPlane and three-dimensional (3D) TOE anatomical PFO sizing techniques. METHODS Imaging data of 45 patients who underwent a 3D TOE-assisted percutaneous PFO closure were studied. The two-dimensional (2D) PFO separation distance and right-to-left (RL) contrast shunt magnitude were assessed on preprocedural TOE recordings. Peri-procedural measurements of the triangular anatomical PFO opening (base, height, and area) were performed after positioning of a stiff guidewire (SW) through the PFO, using Live xPlane imaging and 3D Zoom mode. RESULTS The PFO SW base appeared on average 5 times larger than the preprocedural 2D PFO separation (median difference [IQR] = 13[5] mm; P < .001). For a same PFO separation, the width of the PFO base may vary significantly. The PFO SW base was significantly larger in patients with a large versus a small-to-moderate PFO RL contrast shunt (18 vs 15 mm; P = .007) and in those with a spontaneous versus a provoked shunt (18 vs 14 mm; P = .003). CONCLUSION Live xPlane and 3D Zoom TOE allow peri-procedural measurement of the largest dimension of a PFO, which is the PFO base. Patients with a large or spontaneous RL contrast shunt appear to have a larger PFO base. The anatomical PFO base dimension may be taken into account for optimization of device and patient selection strategies.
Collapse
Affiliation(s)
- Laurent Demulier
- Department of Cardiology, Ghent University Hospital, Ghent, Belgium
| | | | - Ilse Coomans
- Department of Pediatric Cardiology, Ghent University Hospital, Ghent, Belgium
| | | | - Julie De Backer
- Department of Cardiology, Ghent University Hospital, Ghent, Belgium
| | - Laurence Campens
- Department of Cardiology, Ghent University Hospital, Ghent, Belgium
| | - Daniel De Wolf
- Department of Pediatric Cardiology, Ghent University Hospital, Ghent, Belgium
| |
Collapse
|
9
|
Chen J, Li R, Chen J, Zhao J, Li N, Sun S, Yang B. Acute cerebral infarction with acute myocardial infarction due to patent foramen ovale: A case report. Medicine (Baltimore) 2020; 99:e20054. [PMID: 32384468 PMCID: PMC7220755 DOI: 10.1097/md.0000000000020054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
RATIONALE Patent foramen ovale (PFO) is not considered to be the main cause of stroke and is classified as the infarction of undetermined cause. The relationship between PFO and cerebral embolism is still unclear and cerebral embolism accompanied with coronary artery embolization in PFO patient is rare. In this case, we reported a patient with PFO suffered acute cerebral and myocardial infarction simultaneously, and analyzed the source of emboli and potential pathogenesis. PATIENT CONCERNS A 53-year-old female presented with chief complaints of intermittent palpitations and chest tightness for 6 years, aggravated for 3 days. DIAGNOSES During the hospitalization, acute cerebral infarction and acute myocardial infarction occurred at the same time in the patient. The patient felt paroxysmal abdominal pain repeatedly. Finally, we detected PFO in the patient INTERVENTIONS:: Double antiplatelet therapy was given to the patient of acute cerebral and myocardial infarction with PFO. OUTCOMES Two weeks after the onset of the disease, the condition was relatively stable. But after 2 months, the patient experienced repeated heart failure, transthoracic echocardiography manifested no significant change in the PFO gap but significant cardiac function reduction. LESSONS Although a growing number of people are aware that PFO is a risk factor for arterial embolization especially when coexisting with atrial septal aneurysm, a significant proportion of patients have paradoxical embolism after PFO closure. Therefore, transesophageal echocardiography should be routinely performed to find the possible cause of embolism when infarction of undetermined cause occurs, and PFO closure and anti-platelet aggregation or anticoagulant therapy should be given at the same time in order to reduce the occurrence of arterial thrombosis.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Baoming Yang
- Department of Hepatobiliary Surgery, the Fourth Hospital of Hebei Medical University, Shijiazhuang, P. R. China
| |
Collapse
|
10
|
Snijder RJR, Renes LE, Suttorp MJ, Ten Berg JM, Post MC. Percutaneous patent foramen ovale closure using the Occlutech Figulla device: More than 1,300 patient-years of follow up. Catheter Cardiovasc Interv 2019; 93:1080-1084. [PMID: 30461175 DOI: 10.1002/ccd.27984] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 10/22/2018] [Accepted: 10/29/2018] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To evaluate the safety and efficacy of the Occlutech patent foramen ovale (PFO) device at long-term follow-up (FU). BACKGROUND The Occlutech device has been proven safe and effective six-months after percutaneous PFO closure. We describe the safety and efficacy after more than 1,300 patient-years of FU. METHODS All consecutive patients who underwent PFO closure between October 2008 and December 2015 were included. All complications were registered. Residual right-to-left shunt (RLS) was diagnosed using contrast transthoracic echocardiography and graded as minimal, moderate, or severe. RESULTS In total, 250 patients (mean age 53.5 ± 10.7 years, 46.8% female) underwent percutaneous PFO closure using the Occlutech device. Mean FU was 5.9 ± 1.8 years, a total of 1,345 patient-years. Transient ischemic attack (TIA) or stroke was the main indication for closure (89.6%). Implantation was successful in 100%, no major complications occurred. Minor complications were inguinal hematoma in 16 patients (6.4%), pericardial effusion without the need for intervention in one patient (0.4%) and a supraventricular tachycardia in one patient (0.4%). A moderate or large shunt at one-year follow up was present in 5.9%. A cerebrovascular vascular event occurred in 2.0% at 1-year FU (four TIA, one stroke) and in 7.4% at long-term FU (nine TIA, eight stroke). The total cerebrovascular event rate (TIA and CVA) was 0.02% per patient-year of FU, with a stroke rate of 0.01%. CONCLUSION The Occlutech device appears to be safe at long-term FU with a very low annual cerebrovascular event rate and a low moderate to large shunt rate at 1-year FU.
Collapse
Affiliation(s)
- Roel J R Snijder
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Laura E Renes
- Department of Emergency Medicine, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Maarten Jan Suttorp
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Jurrien M Ten Berg
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Martijn C Post
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| |
Collapse
|
11
|
Moon J, Kim M, Oh PC, Shin DH, Park HMI, Jo YY, Lee JS, Kang WC. Residual Shunt after Patent Foramen Ovale Device Closure in Patients With Cryptogenic Stroke: Serial Bubble Contrast Transesophageal Echocardiography Data. J Stroke Cerebrovasc Dis 2019; 28:347-353. [DOI: 10.1016/j.jstrokecerebrovasdis.2018.10.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 09/18/2018] [Accepted: 10/05/2018] [Indexed: 12/19/2022] Open
|
12
|
Pristipino C, Sievert H, D'Ascenzo F, Mas JL, Meier B, Scacciatella P, Hildick-Smith D, Gaita F, Toni D, Kyrle P, Thomson J, Derumeaux G, Onorato E, Sibbing D, Germonpré P, Berti S, Chessa M, Bedogni F, Dudek D, Hornung M, Zamorano J. European position paper on the management of patients with patent foramen ovale. General approach and left circulation thromboembolism. EUROINTERVENTION 2019; 14:1389-1402. [PMID: 30141306 DOI: 10.4244/eij-d-18-00622] [Citation(s) in RCA: 77] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/03/2023]
|
13
|
Chen Q, Cao H, Zhang GC, Chen LW, Xu F, Zhang JX. Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44-48 mm), a single Chinese cardiac center experience. J Cardiothorac Surg 2017; 12:74. [PMID: 28865489 PMCID: PMC5581445 DOI: 10.1186/s13019-017-0639-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 08/27/2017] [Indexed: 11/10/2022] Open
Abstract
Background The purpose of this study was to outline the midterm follow-up results and complications in patients who underwent transthoracic device closure of an atrial septal defect (ASD) with the very large domestic occluder (44–48 mm). Methods The data of 35 patients who underwent transthoracic device closure of an ASD with the very large domestic occluder (44–48 mm) at our institution were collected prospectively between January 2010 and January 2015. All patients were invited for an outpatient visit and contrast TTE for 12–70 months after ASD closure. Results Thirty-four patients were occluded successfully under this approach and 1 patient was transferred for surgical repair for dislodgement of the occluder. The most frequent complication was transient cardiac arrhythmia. A new third degree atrioventricular block occurred in 1 patient who recovered 1 week later. During the follow-up period, we found no recurrence, no thrombosis, no device embolization, no device failure, and no cases of death. The total occlusion rate was 94.1% in the 12 months of follow-up, and the intracardiac structure and cardiac function were significant improved contemporaneously. Conclusion Transthoracic device closure of an atrial septal defect with the very large domestic occluder (44–48 mm) is a safe and feasible technique. However, long-term follow-up is required to better assess the safety and feasibility of this method for the closure of very large ASDs in patients.
Collapse
Affiliation(s)
- Qiang Chen
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Xinquan Road 29#, Fuzhou, 350001, People's Republic of China.
| | - Hua Cao
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Xinquan Road 29#, Fuzhou, 350001, People's Republic of China
| | - Gui-Can Zhang
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Xinquan Road 29#, Fuzhou, 350001, People's Republic of China
| | - Liang-Wan Chen
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Xinquan Road 29#, Fuzhou, 350001, People's Republic of China
| | - Fan Xu
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Xinquan Road 29#, Fuzhou, 350001, People's Republic of China
| | - Jia-Xin Zhang
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Xinquan Road 29#, Fuzhou, 350001, People's Republic of China
| |
Collapse
|
14
|
Nicolosi GL. Potential uselessness and futility of left atrial appendage occlusion and patent foramen ovale closure in cardioembolic stroke. J Cardiovasc Med (Hagerstown) 2017; 18:393-397. [DOI: 10.2459/jcm.0000000000000512] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
15
|
Davies A, Ekmejian A, Collins N, Bhagwandeen R. Multidisciplinary Assessment in Optimising Results of Percutaneous Patent Foramen Ovale Closure. Heart Lung Circ 2016; 26:246-250. [PMID: 27555053 DOI: 10.1016/j.hlc.2016.06.1211] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2016] [Revised: 06/14/2016] [Accepted: 06/16/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Percutaneous patent foramen ovale (PFO) closure is a therapeutic option to prevent recurrent cerebral ischaemia in patients with cryptogenic stroke and transient cerebral ischaemia (TIA). The apparent lack of benefit seen in previous randomised trials has, in part, reflected inclusion of patients with alternate mechanisms of stroke. The role of formal neurology involvement in accurately delineating the likely aetiology of stroke or TIA is crucial in appropriate identification of patients for device closure. Furthermore, as the benefits of device closure may accrue over time, long-term follow-up is essential to define the role of device closure in management of presumed cryptogenic stroke. METHODS We retrospectively reviewed our experience with percutaneous PFO device closure since 2005. All subjects who underwent PFO closure at John Hunter and Lake Macquarie Private Hospitals were included in the study. All patients referred for device closure following cryptogenic stroke or TIA had first undergone formal neurology review with appropriate imaging and exclusion of paroxysmal atrial arrhythmia. Patients with a history of transient ischaemic attack (TIA) are frequently referred to a specialised clinic, aimed to identify patients with conditions not referable to cerebral ischaemia, with investigations initiated by the specialist clinic to elucidate an underlying aetiology. Outcome data was derived from the Hunter New England Area Local Health District Cardiac and Stroke Outcomes Unit, in addition to review of the medical record. The Cardiac and Stroke Outcomes Unit prospectively identified all patients presenting with stroke, TIA and atrial fibrillation. RESULTS One hundred and twelve consecutive patients undergoing percutaneous patent foramen ovale closure between 2005 and 2015 were identified. The average age was 42.7 years and 57 (50.9%) patients were male. Cryptogenic stroke (68.8%) and transient cerebral ischaemia (23.2%) were the most common indications for PFO closure, with the Amplatzer device used in 83 cases (74.1%). Early residual shunting was visible in seven patients (6.3%), however on follow-up agitated saline study only two patients had residual shunt (1.8%). The annual risk of recurrent stroke or TIA was 0.21%. CONCLUSIONS Percutaneous patent foramen ovale closure can be performed safely and effectively in patients with paradoxical embolism. In selected patients, following appropriate multidisciplinary specialist pre-procedural assessment, excellent long-term results with low incidence of recurrent events may be achieved.
Collapse
Affiliation(s)
- Allan Davies
- Department of Cardiovascular Medicine, John Hunter Hospital, Newcastle, NSW, Australia.
| | - Avedis Ekmejian
- Department of Medicine, John Hunter Hospital, Newcastle, NSW, Australia
| | - Nicholas Collins
- Department of Cardiovascular Medicine, John Hunter Hospital, Newcastle, NSW, Australia
| | - Rohan Bhagwandeen
- Department of Cardiovascular Medicine, John Hunter Hospital, Newcastle, NSW, Australia
| |
Collapse
|
16
|
Scalise F, Auguadro C, Sorropago G, Sorropago A, Novelli E, Finizio M, Specchia G. Long-Term Contrast Echocardiography and Clinical Follow-Up after Percutaneous Closure of Patent Foramen Ovale Using Two Different Atrial Septal Occluder Devices. J Interv Cardiol 2016; 29:406-13. [PMID: 27338839 DOI: 10.1111/joic.12314] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
INTRODUCTION Percutaneous patent foramen ovale (PFO) closure by means of a septal occluder device (SOD) is a well-known therapeutic strategy for the secondary prevention of paradoxical embolic neurological events. The aim of this study was to provide long-term echocardiographic and clinical follow-up data on patients who had undergone percutaneous PFO closure with 2 different SOD. METHODS We selected 2 groups of patients treated with 2 different SOD: Group A: 52 patients with an Amplatzer(®) PFO Occluder and Group B: 49 patients with a Figulla Flex(®) device. All patients underwent follow-up Bubble Test Transthoracic Echocardiography (BTTE) and clinical examination. The results were compared with those recently reported in a group of patients with similar characteristics, but that had been treated conservatively, which acted as a control group. RESULTS The mean follow-up after PFO closure was 53 months. The Amplatzer(®) PFO Occluder and the Figulla Flex were used in 52 (51.5%) and 49 (48.5%) of patients, respectively. We found no significant difference in the rate of effective PFO closure between the devices: Amplatzer 91.4%, Figulla 93.9% (P = 0.71). One patient (1.0%) suffered a recurrent neurologic event. BTTE was positive (BTTE+) in 8 patients (8%), 5 with an Amplatzer, and 3 with a Figulla device (P = 0.516). Only 1 patient with BTTE+ had a recurrent TIA (12.5%). No significant relationship was found between device dimensions and BTTE+ (P = 0.062). In the control group (163 patients), the recurrence of neurologic events was 9.2% (15 events), that was significantly higher in respect to the patients who had undergone percutaneous closure of the PFO. CONCLUSIONS Percutaneous PFO closure was associated with a remarkably low risk of recurrent embolic neurological events, and no long-term device-related major complications. No statistically significant difference emerged between the 2 different SODs regarding BTTE positivity. Long-term follow-up showed that the recurrence of neurological events has been significantly higher in the group treated in a conservative way.
Collapse
Affiliation(s)
- Filippo Scalise
- Department of Interventional Cardiology, Policlinico di Monza, Monza, Italy
| | - Carla Auguadro
- Department of Interventional Cardiology, Policlinico di Monza, Monza, Italy
| | - Giovanni Sorropago
- Department of Interventional Cardiology, Policlinico di Monza, Monza, Italy
| | - Antonio Sorropago
- Department of Interventional Cardiology, Policlinico di Monza, Monza, Italy
| | | | - Marica Finizio
- Department of Interventional Cardiology, Policlinico di Monza, Monza, Italy
| | - Giuseppe Specchia
- Department of Interventional Cardiology, Policlinico di Monza, Monza, Italy
| |
Collapse
|