1
|
Bonadiman EA, Fachetti EL, Haiter-Neto F, Pereira TCR, de-Azevedo-Vaz SL. Efficacy of a radiographic film holder adapter in generating radiographs of dental implants with improved geometric accuracy and sharpness. J Prosthet Dent 2024; 132:419.e1-419.e7. [PMID: 38824111 DOI: 10.1016/j.prosdent.2024.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 05/01/2024] [Accepted: 05/04/2024] [Indexed: 06/03/2024]
Abstract
STATEMENT OF PROBLEM Some radiographic film holders produce radiographs with geometric distortion that may interfere with diagnosis. However, whether the distortion can be corrected by adjusting the design of the radiographic film holder is unclear. PURPOSE The purpose of the study was to develop an adapter for a radiographic film holder model aiming to generate radiographs with greater sharpness and a more accurate geometric representation of dental implants. MATERIAL AND METHODS The 2-piece adapter was designed using the SketchUp software program and was 3-dimensionally (3D) printed. Implants with internal conical connections were installed in 19 maxillary prototypes in the central incisor region. Five dentists obtained 285 digital periapical radiographs with 3 different radiographic film holders: standard Cone Indicator, Rinn XCP, and adapted Cone Indicator. They then evaluated the radiographic sharpness of the implants threads and their dimensions using the ImageJ software program. The data were analyzed using the Friedman test with the Durbin-Conover post hoc test and MANOVA with the Tukey post hoc test (α=.05). RESULTS On the mesial surface of the implants, the threads were sharper for the adapted than for the standard Cone Indicator radiographic film holder (P<.05). The adapted Cone Indicator showed a smaller difference between the radiographic and actual implant diameters compared with the Rinn XCP and standard Cone Indicator radiographic film holders (P<.05). CONCLUSIONS The developed adapter provided radiographs of dental implants with improved sharpness and geometric accuracy.
Collapse
Affiliation(s)
- Eduarda Alberti Bonadiman
- Graduate student, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), ES, Brazil
| | | | - Francisco Haiter-Neto
- Professor, Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, SP, Brazil
| | | | - Sergio Lins de-Azevedo-Vaz
- Professor, Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Vitória, ES, Brazil; and Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, ES, Brazil.
| |
Collapse
|
2
|
Mouzinho-Machado S, Borges GB, Pacheco-de-Oliveira-Mota V, de-Azevedo-Vaz SL. Does enhancement filter application increase the diagnostic accuracy of misfit detection at the implant-prosthesis interface? J Prosthet Dent 2024; 131:1136-1143. [PMID: 35570168 DOI: 10.1016/j.prosdent.2022.03.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 03/28/2022] [Accepted: 03/29/2022] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM Misfits at the implant-prosthesis interface may increase complications in dental implants and affect peri-implant tissue health. Periapical radiographs are the most used imaging examinations for detecting misfits at the implant-prosthesis interface, although digital systems have largely replaced film-based radiographs. Whether postprocessing tools such as enhancement filters assist diagnosis by highlighting misfits is unclear. PURPOSE The purpose of this in vitro study was to assess the influence of enhancement filter application in the diagnostic accuracy of misfit detection at the implant-prosthesis interface. MATERIAL AND METHODS A total of 32 dental implants were placed in dry human mandibles. A polyester strip was inserted at the implant-prosthesis interface to simulate a 50-μm misfit; prosthetic crowns installed directly on the implant platforms were used as controls. Standard paralleling periapical images were acquired by using a semidirect system (photostimulable phosphor plate) with the application of Highlight, Invert, and Colorization filters, as well as a direct system (metal oxide complementary semiconductor sensor) with filters Sharpness 3, Invert, and Pseudocolorization. Oral radiologists evaluated the images with and without the application of filters. The areas under the receiver operating characteristics curves (Az values), sensitivity, specificity, accuracy, positive predictive value, and negative predictive values were calculated. The Az values were compared with the receiver operating characteristic (ROC) curves comparison test of the Epidat 3.1 software (α=.05). RESULTS Although images without filter application presented descriptively higher diagnostic values than those with filter application, the Az values for images with and without filter application in both semidirect and direct systems showed no significant differences (P>.05). CONCLUSIONS Enhancement filter application did not significantly influence the diagnostic accuracy of misfit detection at the implant-prosthesis interface.
Collapse
Affiliation(s)
- Sâmia Mouzinho-Machado
- Graduate student, Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Gustavo Bispo Borges
- Predoctoral student, Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Vanessa Pacheco-de-Oliveira-Mota
- Graduate student, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Sergio Lins de-Azevedo-Vaz
- Professor, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil.
| |
Collapse
|
3
|
Garcia CV, Souza DN, Andrade ER. Influence of the Method of Calculating the Effective Atomic Number on the Estimate of Fluorescence Yield for Metal Alloys of Biomedical Interest. HEALTH PHYSICS 2024; 126:188-195. [PMID: 38252033 DOI: 10.1097/hp.0000000000001789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/23/2024]
Abstract
ABSTRACT This study evaluates the influence of the method used to calculate the effective atomic number (Z eff ) on the estimate of secondary radiation yielded under kilovoltage x-ray beams by metal alloys with a wide range of biomedical applications. Two methods for calculating Z eff (referred to here as M 1 and M 2 ) are considered, and six metallic alloys are investigated: Ti-6Al-4 V, Co-Cr-Mo, Ni-Cr-Ti, Ni-Cr, Co-Cr-Mo-W, and Ag 3 Sn-Hg (amalgam). The results indicate significant differences in the estimates of fluorescence yield depending on the method used to estimate Z eff for each metallic alloy. Both the choice of the calculation method for Z eff and the energy ranges of the incident radiation are essential factors affecting the behavior of alloys in terms of fluorescence production. Our results may guide the selection of the best material for a biomedical application. The metallic alloys simulated here show equivalences and discrepancies that depend on the method used to estimate Z eff and the energy range of the incident photons. This finding allows for the creation of combinations of alloys and methods for calculating Z eff and the photon energy to maximize safety and minimize cost.
Collapse
Affiliation(s)
- Caroline V Garcia
- Departamento de Física, Universidade Federal de Sergipe, São Cristóvão, SE, Brazil
| | - Divanizia N Souza
- Departamento de Física, Universidade Federal de Sergipe, São Cristóvão, SE, Brazil
| | | |
Collapse
|
4
|
de Oliveira Mota VP, Braga MS, Loss AA, Mello HN, Rosetti EP, de-Azevedo-Vaz SL. Detection of misfits at the abutment-prosthesis interface in the esthetic zone: Implications of the radiographic technique and the magnitude of the misfit. J Prosthet Dent 2023; 130:239.e1-239.e9. [PMID: 37455164 DOI: 10.1016/j.prosdent.2023.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 05/23/2023] [Accepted: 05/24/2023] [Indexed: 07/18/2023]
Abstract
STATEMENT OF PROBLEM Misfits in the abutment-prosthesis interface represent a setback for implant-supported prostheses. Periapical radiographs have been used as an auxiliary method in the evaluation of prosthesis fit to the abutments; however, the evidence supporting the use of this method is still restricted to studies of low to moderate quality. Furthermore, studies on the diagnostic accuracy of different periapical techniques used to detect misfits in the abutment-prosthesis interface, especially in the esthetic zone, are lacking. PURPOSE The purpose of this in vitro study was to assess the discrimination power of 3 periapical radiographic techniques in detecting misfits at the abutment-prosthesis interface in the esthetic zone and evaluate whether the magnitude of the misfit influenced the diagnosis. MATERIAL AND METHODS A total of 15 implants with an internal conical connection were installed in the central incisor region in polyamide jaws. Custom ceramic copings for cemented crowns were made by using a computer-aided design and computer-aided manufacturing (CAD-CAM) system. Misfits of 50, 100, and 150 µm were simulated by interposing 1, 2, or 3 50-μm-thick polyester strips at the abutment-prosthesis interface; the absence of the strip represented the control group. Digital radiographs were obtained by using film holders for the following periapical techniques: bisecting angle (PBA), standard paralleling (PSP), and modified paralleling (PMP). Two radiologists and 1 prosthodontist evaluated a total of 180 radiographs. The values of the area under the receiver operating characteristic curve (Az) were regarded as a measure of diagnostic accuracy and subjected to the Friedman test with post hoc Durbin-Conover (α=.05). RESULTS The PSP (Az=0.873) had higher Az values than the PBA (Az=0.753) for the 50-μm misfits (P<.05). Larger misfits resulted in greater accuracy than smaller misfits (P<.05). Interactions between the factors radiographic technique and misfit magnitude resulted in statistically significant differences for all comparisons (P<.05), except between the PSP for the 100-μm misfits (Az=0.976) and the PMP for the 150-μm misfits (Az=0.998). CONCLUSIONS The PSP was more accurate than the PBA in detecting the 50-µm misfits at the abutment-prosthesis interface; larger misfits resulted in more accurate diagnoses, regardless of the technique used.
Collapse
Affiliation(s)
- Vanessa Pacheco de Oliveira Mota
- Graduate student, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Manuella Soussa Braga
- Undergraduate student, Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Amanda Alves Loss
- Undergraduate student, Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Hugo Nogueira Mello
- Graduate student, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Elizabeth Pimentel Rosetti
- Professor, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil
| | - Sergio Lins de-Azevedo-Vaz
- Professor, Dental Sciences Graduate Program, Federal University of Espírito Santo (UFES), Vitória, Espírito Santo, Brazil.
| |
Collapse
|
5
|
Alsayed HD. Misfit of Implant-Supported Zirconia (Y-TZP) CAD-CAM Framework Compared to Non-Zirconia Frameworks: A Systematic Review. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:1347. [PMID: 36295507 PMCID: PMC9612252 DOI: 10.3390/medicina58101347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Accepted: 09/19/2022] [Indexed: 11/16/2022]
Abstract
Objective: The aim of the study was to systematically review the overall outcomes of studies comparing the misfit of yttria-stabilized zirconia (Y-TZP) CAD-CAM implant-supported frameworks with frameworks fabricated with other materials and techniques. Methods: An electronic literature search of English literature was performed using Google Scholar, Scopus, Web of Science, MEDLINE (OVID), EMBASE, and PubMed, using predetermined inclusion criteria. Specific terms were utilized in conducting a search from the inception of the respective database up to May 2022. After the search strategy was applied, the data were extracted and the results were analyzed. The focused question was: Is the misfit of the implant-supported zirconia CAD-CAM framework lower than that of non-Y-TZP implant-supported fixed restorations? Results: Eleven articles were included for qualitative assessment and critical appraisal in this review. In the included studies, Y-TZP CAD-CAM implant-supported frameworks were compared to Titanium (Ti), Ni-Cr, Co-Cr, PEEK and high-density polymer, and cast and CAD-CAM frameworks. The studies used scanning electron microscopy, one-screw tests, digital or optical microscopy, 3D virtual assessment, and replica techniques for analyzing the misfit of frameworks. Six studies showed comparable misfits among the Y-TZP CAD-CAM frameworks and the controls. Three studies showed higher misfits for the Y-TZP CAD-CAM frameworks, whereas two studies reported lower misfits for Y-TZP CAD-CAM implant frameworks compared to controls. Conclusion: Y-TZP CAD-CAM implant-supported frameworks have comparable misfits to other implant-supported frameworks. However, due to heterogeneity in the methodologies of the included studies, the overall numerical misfit of the frameworks assessed in the reviewed studies is debatable.
Collapse
Affiliation(s)
- Hussain D Alsayed
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh 60169, Saudi Arabia
| |
Collapse
|
6
|
Misfit detection in implant-supported prostheses of different compositions by periapical radiography and cone beam computed tomography: An in vitro study. J Prosthet Dent 2020; 126:205-213. [PMID: 32723499 DOI: 10.1016/j.prosdent.2020.04.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 04/14/2020] [Accepted: 04/15/2020] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Misfits at the implant-abutment joint (IAJ) can cause the biological and mechanical failure of implant therapy. Standard parallel periapical radiography (PERI) is the method of choice for assessing the fitting of implant-supported prostheses. Although current guidelines do not support the use of cone beam computed tomography (CBCT) solely for misfit detection, CBCT scans can also register misfits as imaging findings. Whether the material used for prostheses manufacturing influences misfit appearance in PERI and CBCT images is unknown. PURPOSE The purpose of this in vitro study was to assess the influence of the type of prosthesis material on misfit detection at the IAJ by using PERI and CBCT. MATERIAL AND METHODS Thirty-two implants with an external hexagon connection were placed in dried human mandibles. Implant-supported crowns were manufactured with different materials and allocated to 3 experimental groups: metal-ceramic (MC), titanium abutment veneered with acrylic resin (TIT), and zirconia abutment veneered with glass-ceramic (ZIR). All crowns were installed both with and without a simulated 200-μm-thick gap at the IAJ (n=64) and were assessed by PERI and CBCT scans. Four dentists evaluated the images for the presence or absence of misfit. Statistical analysis included the Kappa test and areas under the receiver operating characteristics curve (Az values) comparisons (α=.05). RESULTS Kappa values indicated almost perfect intraevaluator and interevaluator reproducibility for PERI and ranged from fair to almost perfect for CBCT. For PERI, Az values were not significantly different among the MC (0.995), TIT (0.997), and ZIR groups (1.000) (P>.05). Regarding CBCT, the Az values found for TIT (0.941) and MC (0.890) were significantly higher than for ZIR (0.762) (P<.05). Az values for PERI were significantly higher than for CBCT (P<.05). CONCLUSIONS The type of prosthesis material did not influence misfit detection at the IAJ with PERI; however, ZIR had lower diagnostic accuracy than TIT and MC implant-supported crowns with CBCT.
Collapse
|
7
|
Francio LA, Silva FE, Valerio CS, Cardoso CAEA, Jansen WC, Manzi FR. Accuracy of various imaging methods for detecting misfit at the tooth-restoration interface in posterior teeth. Imaging Sci Dent 2018; 48:87-96. [PMID: 29963479 PMCID: PMC6015931 DOI: 10.5624/isd.2018.48.2.87] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 02/26/2018] [Accepted: 03/14/2018] [Indexed: 12/31/2022] Open
Abstract
Purpose The present study aimed to evaluate which of the following imaging methods best assessed misfit at the tooth-restoration interface: (1) bitewing radiographs, both conventional and digital, performed using a photostimulable phosphor plate (PSP) and a charge-coupled device (CCD) system; (2) panoramic radiographs, both conventional and digital; and (3) cone-beam computed tomography (CBCT). Materials and Methods Forty healthy human molars with class I cavities were selected and divided into 4 groups according to the restoration that was applied: composite resin, composite resin with liner material to simulate misfit, dental amalgam, and dental amalgam with liner material to simulate misfit. Radiography and tomography were performed using the various imaging methods, and the resulting images were analyzed by 2 calibrated radiologists. The true presence or absence of misfit corresponding to an area of radiolucency in regions subjacent to the esthetic and metal restorations was validated with microscopy. The data were analyzed using a receiver operating characteristic (ROC) curve, and the scores were compared using the Cohen kappa coefficient. Results For bitewing images, the digital systems (CCD and PSP) showed a higher area under the ROC curve (AUROC) for the evaluation of resin restorations, while the conventional images exhibited a larger AUROC for the evaluation of amalgam restorations. Conventional and digital panoramic radiographs did not yield good results for the evaluation of resin and amalgam restorations (P<.05). CBCT images exhibited good results for resin restorations (P>.05), but showed no discriminatory ability for amalgam restorations (P<.05). Conclusion Bitewing radiographs (conventional or digital) should be the method of choice when assessing dental restoration misfit.
Collapse
Affiliation(s)
| | | | - Claudia Scigliano Valerio
- Department of Oral Radiology, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Brazil
| | | | | | - Flávio Ricardo Manzi
- Department of Oral Radiology, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Brazil
| |
Collapse
|
8
|
Darós P, Carneiro VC, Siqueira AP, de-Azevedo-Vaz SL. Diagnostic accuracy of 4 intraoral radiographic techniques for misfit detection at the implant abutment joint. J Prosthet Dent 2017; 120:57-64. [PMID: 29150129 DOI: 10.1016/j.prosdent.2017.08.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Revised: 08/08/2017] [Accepted: 08/08/2017] [Indexed: 11/26/2022]
Abstract
STATEMENT OF PROBLEM A misfit or gap at the implant-abutment joint (IAJ) requires detection as it may compromise the health of the peri-implant tissue. However, which radiographic technique provides the most orthogonal relationship between the central beam and the implant/image receptor is unclear. PURPOSE The purpose of this in vitro study was to evaluate the diagnostic accuracy of 4 intraoral radiographic techniques on misfit detection at the IAJ. MATERIAL AND METHODS Twenty implants were placed in polyamide jaws, and customized dental implant abutments with a metal collar were installed. Different gaps were simulated by placing one or three 50-μm-thick polyester strips at the IAJ; the absence of the strip represented the control group (no gap). The 4 radiographic techniques were evaluated by using different film holders: a periapical with bisecting angle (PBA), a bitewing interproximal (BI), a periapical with standard paralleling (PSP), and a periapical with modified paralleling (PMP) holder (with a custom-made paralleling index). A total of 240 digital radiographs were evaluated by 4 clinicians experienced with dental implants. Differences were evaluated by using receiver operating characteristic (ROC) curves (Az) and Fisher tests (α=.05). Diagnostic values (sensitivity, specificity, accuracy, and positive and negative predictive values) were also obtained. The Kappa test was used to assess intra- and interevaluator reproducibility, which ranged from moderate to almost perfect. RESULTS All diagnostic values, except specificity, were lower for the PBA technique for both the 50- and 150-μm gaps. Az values for the PBA technique were significantly lower than those obtained for the other 3 techniques (P<.05), which did not differ from each other. The 150-μm gaps were more easily detected than the 50-μm gaps only for PBA (P<.05). CONCLUSIONS The BI, PSP, and PMP techniques detected misfits at the IAJ most accurately. The PBA technique is not recommended for this purpose.
Collapse
Affiliation(s)
- Pollyana Darós
- Postgraduate student, Department of Clinical Dentistry, Federal University of Espírito Santo, Espírito Santo, Brazil
| | - Vinícius Cavalcanti Carneiro
- Postgraduate student, Department of Clinical Dentistry, Federal University of Espírito Santo, Espírito Santo, Brazil
| | - Amanda Pasolini Siqueira
- Predoctoral student, Department of Clinical Dentistry, Federal University of Espírito Santo, Espírito Santo, Brazil
| | - Sergio Lins de-Azevedo-Vaz
- Professor, Departament of Clinical Dentistry, Federal University of Espírito Santo, Espírito Santo, Brazil.
| |
Collapse
|
9
|
Donovan TE, Marzola R, Becker W, Cagna DR, Eichmiller F, McKee JR, Metz JE, Albouy JP. Annual review of selected scientific literature: Report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2015; 114:756-809. [PMID: 26611624 DOI: 10.1016/j.prosdent.2015.10.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Accepted: 10/13/2015] [Indexed: 10/22/2022]
Affiliation(s)
- Terence E Donovan
- Chair, Committee on Scientific Investigation, American Academy of Restorative Dentistry (AARD); and Professor and Chair for Biomaterials, Department of Operative Dentistry, University of North Carolina School of Dentistry at Chapel Hill, NC.
| | - Riccardo Marzola
- Adjunct Professor, Fixed Implant Prosthodontics, University of Bologna; and Private practice, Ferrara, Italy
| | - William Becker
- Clinical Professor, Advanced Education in Prosthodontics, Herman Ostrow School of Dentistry, Los Angeles, Calif
| | - David R Cagna
- Associate Dean, Professor and Director, Advanced Prosthodontics, University of Tennessee Health Sciences Center, Memphis, Tenn
| | - Frederick Eichmiller
- Vice President and Dental Director, Delta Dental of Wisconsin, Stevens Point, Wisc
| | | | | | | |
Collapse
|