Gradinaru I, Ciubotaru BI, Butnaru M, Cojocaru FD, Covașă CT, Bibire T, Dascalu M, Bargan A, Cazacu M, Zaltariov MF. The Impact of the Addition of Vitamins on a Silicone Lining Material to the Oral Mucosa Tissue-Evaluation of the Biocompatibility, Hydrolytic Stability and Histopathological Effect. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1936. [PMID: 38003985 PMCID: PMC10673301 DOI: 10.3390/medicina59111936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Revised: 10/20/2023] [Accepted: 10/27/2023] [Indexed: 11/26/2023]
Abstract
Background and Objectives: One's quality of life depends on overall health, and in particular, oral health, which has been and continues to become a public health issue through frequent manifestations in various forms, from simple oral stomatitis (inflammations of the oral cavity) to the complicated oral health pathologies requiring medical interventions and treatments (caries, pulp necrosis and periodontitis). The aim of this study focused on the preparation and evaluation of vitamins (vitamin A, B1 and B6) incorporated into several silicone-based lining materials as a new alternative to therapeutically loaded materials designed as oral cavity lining materials in prosthodontics. Materials and Methods: Silicone-based liners containing vitamins were prepared by mixing them in solution and becoming crosslinked, and then they were characterized using Fourier-transform infrared (FT-IR) spectroscopy to confirm the incorporation of the vitamins into the silicone network; scanning electron microscopy (SEM) to evidence the morphology of the liner materials; dynamic vapor sorption (DVS) to evaluate their internal hydrophobicity, swelling in environments similar to biological fluids and mechanical test to demonstrate tensile strength; MTT to confirm their biocompatibility on normal cell cultures (fibroblast) and mucoadhesivity; and histopathological tests on porcine oral mucosa to highlight their potential utility as soft lining materials with improved efficiency. Results: FT-IR analysis confirmed the structural peculiarities of the prepared lining materials and the successful incorporation of vitamins into the silicone matrix. The surface roughness of the materials was lower than 0.2 μm, while in cross-section, the lining materials showed a compact morphology. It was found that the presence of vitamins induced a decrease in the main mechanical parameters (strength and elongation at break, Young's modulus) and hydrophobicity, which varied from one vitamin to another. A swelling degree higher than 8% was found in PBS 6.8 (artificial saliva) and water. Hydrolytic stability studies in an artificial saliva medium showed the release of low concentrations of silicone and vitamin fragments in the first 24 h, which increased the swelling behavior of the materials, diffusion and solubility of the vitamins. The microscopic images of fibroblast cells incubated with vitamin liners revealed very good biocompatibility. Also, the silicone liners incorporating the vitamins showed good mucoadhesive properties. The appearance of some pathological disorders with autolysis processes was more pronounced in the case of vitamin A liners. Conclusions: The addition of the vitamins was shown to have a beneficial effect that was mainly manifested as increased biocompatibility, hydrolytic stability and mucoadhesiveness with the mucosa of the oral cavity and less of an effect on the mechanical strength. The obtained lining materials showed good resistance in simulated biological media but caused a pronounced autolysis phenomenon, as revealed by histopathological examination, showing that these materials may have broad implications in the treatment of oral diseases.
Collapse
Affiliation(s)
- Irina Gradinaru
- Department of Implantology, Removable Dentures, Technology, “Grigore T. Popa” University of Medicine and Pharmacy, 16 Universitatii Street, 700115 Iasi, Romania;
| | - Bianca Iulia Ciubotaru
- Department of Inorganic Polymers, “Petru Poni” Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda 41 A, 700487 Iasi, Romania; (B.I.C.); (M.D.); (A.B.); (M.C.)
| | - Maria Butnaru
- Biomedical Sciences Department, Faculty of Medical Bioengineering, “Grigore T. Popa” University of Medicine and Pharmacy, 9-13 Kogalniceanu Street, 700454 Iasi, Romania; (M.B.); (F.D.C.)
| | - Florina Daniela Cojocaru
- Biomedical Sciences Department, Faculty of Medical Bioengineering, “Grigore T. Popa” University of Medicine and Pharmacy, 9-13 Kogalniceanu Street, 700454 Iasi, Romania; (M.B.); (F.D.C.)
| | - Costică Toader Covașă
- Faculty of Veterinary Medicine, “Ion Ionescu de la Brad” University of Life Sciences—IULS, Aleea Mihail Sadoveanu nr. 3, 700490 Iasi, Romania;
| | - Teofana Bibire
- Faculty of General Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 16 Universitatii Street, 700115 Iasi, Romania;
| | - Mihaela Dascalu
- Department of Inorganic Polymers, “Petru Poni” Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda 41 A, 700487 Iasi, Romania; (B.I.C.); (M.D.); (A.B.); (M.C.)
| | - Alexandra Bargan
- Department of Inorganic Polymers, “Petru Poni” Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda 41 A, 700487 Iasi, Romania; (B.I.C.); (M.D.); (A.B.); (M.C.)
| | - Maria Cazacu
- Department of Inorganic Polymers, “Petru Poni” Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda 41 A, 700487 Iasi, Romania; (B.I.C.); (M.D.); (A.B.); (M.C.)
| | - Mirela-Fernanda Zaltariov
- Department of Inorganic Polymers, “Petru Poni” Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda 41 A, 700487 Iasi, Romania; (B.I.C.); (M.D.); (A.B.); (M.C.)
| |
Collapse
|
2
|
Alqutaibi AY, Alnazzawi AA, Farghal AE, Bakr RM, Mahmoud II. Impact of Acrylic and Silicone-Based Soft-Liner Materials on Biting Force and Quality of Life of the Complete Denture Wearers: A Randomized Clinical Trial. J Clin Med 2023; 12:jcm12052073. [PMID: 36902859 PMCID: PMC10003938 DOI: 10.3390/jcm12052073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 02/28/2023] [Accepted: 03/01/2023] [Indexed: 03/08/2023] Open
Abstract
This rerandomized clinical trial evaluated the influence of soft liners (SL) on biting force, pain perception, and the oral health-related quality of life (OHRQoL) of complete denture wearers. Twenty-eight completely edentulous patients complaining of ill-fitting lower complete dentures were selected to participate in the study from the Dental Hospital, College of Dentistry, Taibah University. All patients received new complete maxillary and mandibular dentures; then they were randomly divided into two groups (14 patients in each group): the acrylic-based SL group, in which the mandibular denture was lined with an acrylic-based soft liner, and the silicone-based SL group, in which the mandibular denture was lined with a silicone-based soft liner. OHRQoL and maximum bite force (MBF) were assessed in this study before denture relining (baseline), then at one month and three months after relining. The finding showed that both treatment modalities significantly improved the OHRQoL of included patients at one-month and three-month periods compared to baseline records (i.e., dentures before relining) with a statistically significant difference (p < 0.05). However, there is no statistical difference between groups at the baseline, one-, and three-month follow-up periods. Regarding maximum biting force, when acrylic-based SL is compared to silicone-based SL, there is no statistical difference between groups at baseline (75 ± 31 and 83 ± 32 N) and one-month follow-up periods (145 ± 53 and 156 ± 49 N); however, after three months of function, the silicone-based group recorded 166 ± 57 N statistically significant high biting force compared to the acrylic-based group that recorded 116 ± 47 N (p < 0.05). Permanent soft denture liners positively affect maximum biting force, pain perception, and OHRQoL more than conventional dentures. After three months, silicone-based SL outperformed acrylic-based soft liners in maximum biting force, which may indicate better long-term results.
Collapse
Affiliation(s)
- Ahmed Yaseen Alqutaibi
- Substitutive Dental Sciences Department, College of Dentistry, Taibah University, Al Madinah 41311, Saudi Arabia
- Prosthodontics Department, College of Dentistry, Ibb University, Ibb 70270, Yemen
- Correspondence:
| | - Ahmad A. Alnazzawi
- Substitutive Dental Sciences Department, College of Dentistry, Taibah University, Al Madinah 41311, Saudi Arabia
| | - Ahmed E. Farghal
- Substitutive Dental Sciences Department, College of Dentistry, Taibah University, Al Madinah 41311, Saudi Arabia
| | - Ramy M. Bakr
- Removable Prosthodontics Department, Future University, Cairo 11835, Egypt
| | - Ihab Ismail Mahmoud
- Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo 11884, Egypt
| |
Collapse
|
3
|
Mumcu E, Topcu Ersöz MB, Avukat EN, Akay C, Pat S. Influence of oxygen effect in coating layer on tensile bond strength of PMMA. INT J POLYM MATER PO 2022. [DOI: 10.1080/00914037.2022.2029441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Emre Mumcu
- Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskişehir, Turkey
- Advanced Material Technologies Application and Research Center, Osmangazi University, Eskisehir, Turkey
| | | | - Esra Nur Avukat
- Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskişehir, Turkey
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskişehir, Turkey
- Advanced Material Technologies Application and Research Center, Osmangazi University, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Suat Pat
- Advanced Material Technologies Application and Research Center, Osmangazi University, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
- Department of Physics, Faculty of Science and Letters, Eskisehir Osmangazi University, Eskişehir, Turkey
| |
Collapse
|
4
|
Mańka-Malara K, Trzaskowski M, Gawlak D. The Influence of Decontamination Procedures on the Surface of Two Polymeric Liners Used in Prosthodontics. Polymers (Basel) 2021; 13:4340. [PMID: 34960891 PMCID: PMC8706804 DOI: 10.3390/polym13244340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 12/01/2021] [Accepted: 12/08/2021] [Indexed: 11/18/2022] Open
Abstract
Polymeric liners are materials commonly used in prosthodontics to reshape denture surfaces contacting the soft tissues of the oral cavity. The aim of the study was to determine the impact of different cleaning methods on two polymeric materials used in prosthodontics as non-adhesive permanent liners. The material for the research consisted of samples made from Mollosil Plus (Detax, Ettlingen, Germany)-direct polysiloxan liner; and Plastitanium (Pressing Dental, San Marino, Republic of San Marino)-an injection-molded liner. A total of 198 samples were made, 99 of each assessed material. They were exposed to different cleaning methods-a toothbrush, a toothbrush and soap, a toothbrush and toothpaste (BlendaMed, Procter&Gamble, Cincinnati, OH, USA), a toothpaste and denture cleaning paste (Protefix Hygiene Denture Paste, Queisser Pharma, Germany), denture cleansing tablets (Protefix Hygiene Cleaning Tablets, Queisse Pharma, Germany), and a disinfecting spray (Aftermat, Port Jefferson Station, New York City, NY, USA)-for 1 min, 5 min, 10 min, and 15 min. The image acquisition was performed with scanning electron microscopy and samples were analyzed for the homogeneity of their surfaces-the presence of holes, grooves, precipitate, and small and large separating pieces of the material marking departures from this homogeneity. For each type of damage, one point was given. Continuous data from two groups were compared with Mann-Whitney U testing. Due to a small sample size and distribution of variables other than normal, to compare more than two groups, Kruskal-Wallis testing with post hoc analysis (Dunn test with Bonferroni correction) was used. Categorical data were compared with the chi-square test and the Fisher's exact test. The Mollosil Plus material should be decontaminated with the use of a toothbrush or toothbrush with soap, while Plastitanium material should be disinfected. Plastitanium samples are more susceptible to damage during the decontamination procedures than Mollosil Plus.
Collapse
Affiliation(s)
- Katarzyna Mańka-Malara
- Department of Prosthodontics, Medical University of Warsaw, 02-097 Warsaw, Poland; (M.T.); (D.G.)
| | | | | |
Collapse
|
5
|
Soft Denture Liner Adhesion to Conventional and CAD/CAM Processed Poly(Methyl Methacrylate) Acrylic Denture Resins-An In-Vitro Study. MATERIALS 2021; 14:ma14216614. [PMID: 34772140 PMCID: PMC8585430 DOI: 10.3390/ma14216614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 10/28/2021] [Accepted: 11/01/2021] [Indexed: 12/04/2022]
Abstract
This study aimed to evaluate the airborne-particle abrasion surface treatment effects on the tensile bond strength (TBS) between resilient denture liner and CAD/CAM or conventional heat polymerized poly (methyl methacrylate) (PMMA) acrylic denture resins. A total of 48 dumbbell-shaped specimens (70 mm in total length, and 12 mm and 7 mm in diameter at the thickest and thinnest section, respectively) were prepared from CAD/CAM and conventional acrylic resins. Before relining with denture liner, 12 specimens from each material were surface-treated by 110 µm Al2O3 airborne-particle abrasion, and the remaining specimens served as control (no treatment). Following relining, all the specimens were aged by thermal cycling (1000 cycles, 5–55 °C). The TBS of denture liner to acrylic denture resins was tested in a universal testing apparatus at a 5 mm/min crosshead speed. The debonded surfaces were visually examined for the failure modes. ANOVA and multiple comparisons posthoc analysis tests were applied to determine the significant difference in TBS between the study groups (α = 0.05). A significant difference in TBS was observed between the control and surface treated groups (p < 0.001) for both acrylic resins materials. However, there was no statistically significant difference in bond strength between the acrylic resins materials (p = 0.739). Surface treatment with airborne-particle abrasion demonstrated increased TBS of the soft denture liners to acrylic resins. The TBS of conventional and CAD/CAM acrylic resins to soft denture liners were not considerably different.
Collapse
|
6
|
Zafar MS. Prosthodontic Applications of Polymethyl Methacrylate (PMMA): An Update. Polymers (Basel) 2020; 12:E2299. [PMID: 33049984 PMCID: PMC7599472 DOI: 10.3390/polym12102299] [Citation(s) in RCA: 193] [Impact Index Per Article: 48.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Revised: 10/01/2020] [Accepted: 10/02/2020] [Indexed: 12/16/2022] Open
Abstract
A wide range of polymers are commonly used for various applications in prosthodontics. Polymethyl methacrylate (PMMA) is commonly used for prosthetic dental applications, including the fabrication of artificial teeth, denture bases, dentures, obturators, orthodontic retainers, temporary or provisional crowns, and for the repair of dental prostheses. Additional dental applications of PMMA include occlusal splints, printed or milled casts, dies for treatment planning, and the embedding of tooth specimens for research purposes. The unique properties of PMMA, such as its low density, aesthetics, cost-effectiveness, ease of manipulation, and tailorable physical and mechanical properties, make it a suitable and popular biomaterial for these dental applications. To further improve the properties (thermal properties, water sorption, solubility, impact strength, flexural strength) of PMMA, several chemical modifications and mechanical reinforcement techniques using various types of fibers, nanoparticles, and nanotubes have been reported recently. The present article comprehensively reviews various aspects and properties of PMMA biomaterials, mainly for prosthodontic applications. In addition, recent updates and modifications to enhance the physical and mechanical properties of PMMA are also discussed.
Collapse
Affiliation(s)
- Muhammad Sohail Zafar
- Department of Restorative Dentistry, College of Dentistry, Taibah University, Al Madinah, Al Munawwarah 41311, Saudi Arabia
- Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad 44000, Pakistan
| |
Collapse
|
7
|
Herla M, Boening K, Meissner H, Walczak K. Mechanical and Surface Properties of Resilient Denture Liners Modified with Chitosan Salts. MATERIALS (BASEL, SWITZERLAND) 2019; 12:ma12213518. [PMID: 31717771 PMCID: PMC6862088 DOI: 10.3390/ma12213518] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 10/14/2019] [Accepted: 10/22/2019] [Indexed: 06/10/2023]
Abstract
Chitosan (CS) and its derivatives show antibacterial and antifungal properties and could help treat and prevent denture stomatitis (DS). Mechanical and surface properties of resilient denture liners were evaluated when modified with CS salts. CS-hydrochloride (CS-HCl) and CS-glutamate (CS-G) were added to resilient denture liners Ufi Gel P and Coe-Soft at four different concentrations (0.1%, 0.2%, 0.4%, 1% w/w) from which specimens were produced, as well as a control group of each material with no added CS salt. Ten specimens per group (Ø 35 mm, height 6 mm) were manufactured. They were stored in distilled water at 37 °C for a total of 30 days (d). Shore A hardness (SHA) and surface roughness (Ra) were evaluated after 24 h (T1), 7 d (T2), 14 d (T3) and 30 d (T4). Kruskal-Wallis and U-test (Bonferroni-Holm adjusted) were used for statistical analysis (p ≤ 0.05). Ra increased significantly once CS salts were added. SHA increased significantly for some groups, but all specimens fulfilled requirements set by ISO 10139-2:2016. Modification with CS salts does not influence the mechanical properties of the modified resilient denture liners in a clinically relevant manner. Despite the increased roughness, the concept is suitable for further studies. Especially antimicrobial/antibiofilm studies are needed.
Collapse
|
8
|
Kreve S, Oliveira VC, Bachmann L, Alves OL, Reis ACD. Influence of AgVO 3 incorporation on antimicrobial properties, hardness, roughness and adhesion of a soft denture liner. Sci Rep 2019; 9:11889. [PMID: 31417116 PMCID: PMC6695436 DOI: 10.1038/s41598-019-48228-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Accepted: 07/23/2019] [Indexed: 11/09/2022] Open
Abstract
The objective of this in vitro study was to investigate the effect of nanostructured silver vanadate decorated with silver nanoparticles (AgVO3) on antimicrobial activity, hardness, roughness, and adhesion of a soft denture liner. The antimicrobial efficacy of the Trusoft (Boswoth) liner incorporated with different concentrations of AgVO3 against Enterococcus faecalis, Pseudomonas aeruginosa, Candida albicans, and Staphyloccocus aureus (n = 5) was evaluated by the agar diffusion method. Roughness, hardness, and adhesion properties were also evaluated. The data were analyzed by analysis of variance (ANOVA) and Tukey's multiple comparison test with significance at the p < 0.05 level. At concentrations of 1 and 2.5%, AgVO3 incorporation was effective only against E. faecalis, and at 5 and 10%, against E. faecalis, P. aeruginosa, and C. albicans. None of the concentrations was effective against S. aureus. A decrease in hardness was found for the 1, 2.5, and 10% AgVO3 concentrations (p < 0.001) and at 5%, hardness was not affected. None of the concentrations affected the roughness of the material. A significant increase in tensile values was observed between the liner and heat-curing acrylic resin for 2.5% (p < 0.001) and 10% (p = 0.042) concentrations. AgVO3 incorporation to a soft denture liner promoted antimicrobial activity against E. faecalis, P. aeruginosa, and C. albicans without affecting roughness, maintaining the hardness properties recommended for soft and extra soft liners, and improving the adhesion between the liner and the acrylic resin used for dentures.
Collapse
Affiliation(s)
- Simone Kreve
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Viviane C Oliveira
- Technique of Oral Rehabilitation Laboratory, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, Brazil
| | - Luciano Bachmann
- Department of Physics, University of São Paulo - School of Philosophy, Sciences and Letters of Ribeirão Preto, Ribeirão Preto, São Paulo, Brazil
| | - Oswaldo L Alves
- Laboratory of Solid State Chemistry, State University of Campinas (UNICAMP), Campinas, Brazil
| | - Andréa C Dos Reis
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Ribeirão Preto, SP, Brazil.
| |
Collapse
|
9
|
Denture Liners: A Systematic Review Relative to Adhesion and Mechanical Properties. ScientificWorldJournal 2019; 2019:6913080. [PMID: 30940994 PMCID: PMC6421019 DOI: 10.1155/2019/6913080] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Revised: 01/25/2019] [Accepted: 02/13/2019] [Indexed: 01/23/2023] Open
Abstract
Purpose The objective of this systematic review is to compare results concerning the properties of adhesion, roughness, and hardness of dental liners obtained in the last ten years. Methods Searches on the databases LILACS, PubMed/Medline, Web of Science, and Cochrane Database of Systematic Reviews were supplemented with manual searches conducted between February and April of 2018. The inclusion criteria included experimental in vitro and in vivo, clinical, and laboratory studies on resilient and/or hard liners, assessment of hardness, roughness, and/or adhesion to the denture base, and physical/mechanical changes resulting from the disinfection process and changes in liners' composition or application. Results A total of 406 articles were identified and, from those, 44 are discussed. Twenty-four studies examined the bond strength, 13 surface roughness, and 19 the hardness. Of these 44 studies, 12 evaluated more than one property. Different substances were used in the attempt to improve adhesion. Considering roughness and hardness, the benefits of sealants have been tested, and the changes resulting from antimicrobial agents' incorporation have been assessed. Conclusion Adhesion to the prosthesis base is improved with surface treatments. Rough surfaces and changes in hardness compromise the material's serviceability.
Collapse
|
10
|
Araújo CU, Basting RT. In situ evaluation of surface roughness and micromorphology of temporary soft denture liner materials at different time intervals. Gerodontology 2017; 35:38-44. [PMID: 29205473 DOI: 10.1111/ger.12314] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/13/2017] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To perform an in situ evaluation of surface roughness and micromorphology of two soft liner materials for dentures at different time intervals. BACKGROUND The surface roughness of materials may influence the adhesion of micro-organisms and inflammation of the mucosal tissues. The in situ evaluation of surface roughness and the micromorphology of soft liner materials over the course of time may present results different from those of in vitro studies, considering the constant presence of saliva and food, the changes in temperature and the pH level in the oral cavity. MATERIALS AND METHODS Forty-eight rectangular specimens of each of the two soft liner materials were fabricated: a silicone-based material (Mucopren Soft) and an acrylic resin-based material (Trusoft). The specimens were placed in the dentures of 12 participants (n = 12), and the materials were evaluated for surface roughness and micromorphology at different time intervals: 0, 7, 30 and 60 days. Roughness (Ra) was evaluated by means of a roughness tester. Surface micromorphology was evaluated by scanning electron microscopy. RESULTS Analysis of variance for randomised block design and Tukey's test showed that surface roughness values were lower in the groups using the silicone-based material at all the time intervals (P < .0001). The average surface roughness was higher at time interval 0 than at the other intervals, for both materials (P < .0001). The surface micromorphology showed that the silicone material presented a more regular and smoother surface than the acrylic resin-based material. CONCLUSION The surface roughness of acrylic resin-based and silicone-based denture soft liner materials decreased after 7 days of evaluation, leading to a smoother surface over time. The silicone-based material showed lower roughness values and a smoother surface than the acrylic resin-based material, thereby making it preferred when selecting more appropriate material, due its tendency to promote less biofilm build-up.
Collapse
Affiliation(s)
- Célio U Araújo
- São Leopoldo Mandic Institute and Dental Research Center, Campinas, SP, Brazil
| | - Roberta T Basting
- São Leopoldo Mandic Institute and Dental Research Center, Campinas, SP, Brazil
| |
Collapse
|
11
|
Meister LMB, Bail M, Pellissari CVG, Ban MDCI, Campagnoli EB, Jorge JH, Campanha NH. Description of a Rat Palatal Acrylic Plate That Can Be Relined. J Prosthodont 2015; 24:562-568. [PMID: 25556822 DOI: 10.1111/jopr.12247] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/03/2014] [Indexed: 11/29/2022] Open
Abstract
PURPOSE The objective of this article is to describe a method to construct an intraoral acrylic device that permits a reline material to be added to the inner surface of the palatal plate. MATERIALS AND METHODS Fifteen 60-day-old adult female rats (Rattus Norvegicus Albinus Wistar), weighing 150 to 250 g were used for this study and allocated to three groups (n = 5): G1, animals wearing a heat-polymerized acrylic resin palatal plate (Lucitone 550) for 14 days; G2, animals wearing a heat-polymerized acrylic resin palatal plate (Lucitone 550) relined with Tokuyama Rebase II for 14 days; and G3, animals maintained under the same conditions as the experimental groups, without wearing palatal plates for 14 days. The manipulation of the animals followed the guidelines of the Brazilian College of Animal Experimentation, under the approval of the animal ethics committee of the State University of Ponta Grossa. The palatal plates covered the whole palate, were fixed in the molar region with light-cured resin, and were kept there for 14 days. The animals received a paste diet and water ad libitum. Before and after the trial period, the rats were weighed individually on a precision scale. Statistical analysis was performed using a two-way analysis of variance (α = 0.05) test for comparison of the animals' weight (g) at time 0 and after 14 days of using the palatal plate. RESULTS No statistical differences were observed regarding the weight of the animals among the experimental groups in the study. CONCLUSIONS The individual master impressions, the molar teeth coverage, and the method of cementation with nonadhesive composite resin provided good stability for the palatal plate showed in this study, not disturbing the eating habits and nutrition of the animals. This model seems reproducible, offering adequate histopathological evaluation. Differences in tissue morphology exist between the animals that used the palatal plate and the animals that did not use this device. Use of these palatal plates could clarify how prostheses bring changes in the palatal mucosa of users.
Collapse
Affiliation(s)
| | - Michele Bail
- Department of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil.,University Center of Varzea Grande -UNIVAG, Várzea Grande, Mato Grosso, Brazil
| | | | | | | | - Janaina Habib Jorge
- Department of Dental Materials and Prosthodontics, Araraquara Dental School, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - Nara Hellen Campanha
- Department of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| |
Collapse
|