1
|
Braz GL, Vasconcelos ACU, Gomes APN, Calderipe CB, Soares AC. Adenomatoid hyperplasia of minor salivary glands: a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol 2025; 139:229-241. [PMID: 39572301 DOI: 10.1016/j.oooo.2024.10.081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 10/13/2024] [Accepted: 10/16/2024] [Indexed: 01/11/2025]
Abstract
OBJECTIVE To systematically review available data regarding adenomatoid hyperplasia of minor salivary glands (AHMSG). STUDY DESIGN Electronic searches were performed in six databases and gray literature. The risk of bias was assessed using the Joanna Briggs Institute tool. RESULTS Forty studies reporting 121 cases of AHMSG were included. There is a male predominance (n = 72/64.29%), with individuals in their fourth and fifth decade of life being the most affected. The palate was the main anatomical location (n = 90/74.39%), and most lesions presented as single, asymptomatic nodules. The mean size of AHMSGs was 1.48 ± 0.77 cm, and the mean evolution time was 16.84 ± 25.67 months. Immunohistochemical evaluation in three cases (2.48%) showed a low labeling index for Ki-67 (n = 2/66.67%) and proliferating cell nuclear antigen (n = 1/33.33%). CONCLUSIONS AHMSG is an uncommon benign lesion with no tendency to recur after initial surgical removal. The main histological features include an abundant proliferation of glandular acini, occasional ductal dilation, and sometimes the presence of inflammatory infiltrate. Pathologists and clinicians should be aware of AHMSG, as it can closely resemble both benign and malignant salivary gland lesions.
Collapse
Affiliation(s)
- Gabriel Lima Braz
- Diagnostic Center of Oral Diseases, Dental School, Federal University of Pelotas-UFPel, Pelotas, Rio Grande do Sul, Brazil
| | - Ana Carolina Uchoa Vasconcelos
- Diagnostic Center of Oral Diseases, Dental School, Federal University of Pelotas-UFPel, Pelotas, Rio Grande do Sul, Brazil.
| | - Ana Paula Neutzling Gomes
- Diagnostic Center of Oral Diseases, Dental School, Federal University of Pelotas-UFPel, Pelotas, Rio Grande do Sul, Brazil
| | - Camila Barcellos Calderipe
- Department of Oral Diagnosis, Piracicaba School of Dentistry, Campinas State University-UNICAMP, Piracicaba, São Paulo, Brazil
| | - Alini Cardoso Soares
- Diagnostic Center of Oral Diseases, Dental School, Federal University of Pelotas-UFPel, Pelotas, Rio Grande do Sul, Brazil
| |
Collapse
|
2
|
Almutairi M, Byun S, Chee W, Park C. Conversion of a failing fixed implant prosthesis into an implant-retained overdenture: A clinical report. J Prosthet Dent 2024:S0022-3913(24)00712-1. [PMID: 39567302 DOI: 10.1016/j.prosdent.2024.10.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2024] [Revised: 10/10/2024] [Accepted: 10/14/2024] [Indexed: 11/22/2024]
Abstract
Implants supporting a fixed prosthesis may fail leaving unfavorable implant distribution for a fixed prosthesis. This clinical report illustrates a treatment option for converting a failing fixed prosthesis into a mandibular complete overdenture by using a portion of the existing fixed implant prosthesis. The use of a resilient liner to retain a converted mandibular overdenture framework provided satisfactory results in the first year of clinical use.
Collapse
Affiliation(s)
- Mohammad Almutairi
- Former Resident, Advanced Education in Prosthodontics, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, Calif.
| | - Sangho Byun
- Clinical Assistant Professor, Advanced Education in Prosthodontics, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, Calif
| | - Winston Chee
- Ralph & Jean Bleak Professor of Restorative Dentistry, Advanced Education in Prosthodontics, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, Calif
| | - Cheryl Park
- Associate Professor and Carl Rieder Professor of Restorative Dentistry, Director of Advanced Education in Prosthodontics, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, Calif
| |
Collapse
|
3
|
Pachiou A, Karakostas P, Roulias P, Naka O. Clinical parameters that affect performance and patient satisfaction of root-retained overdentures: A systematic review of randomised controlled clinical trials. Gerodontology 2024; 41:328-334. [PMID: 38247020 DOI: 10.1111/ger.12739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/01/2024] [Indexed: 01/23/2024]
Abstract
OBJECTIVE To evaluate clinical parameters that affect the performance of root-supported overdentures (ROD) and to identify the possible factors that may affect it. BACKGROUND ROD still serve as an alternative and successful treatment plan nowadays for partially edentulous patients. Nonetheless, there is not yet conclusive evidence about their clinical evaluation. MATERIALS AND METHODS A search strategy was developed following a PIO (Population, Intervention, Outcome) framework including an electronic search in the following databases: PubMed, Cochrane Library and Scopus. The systematic search included only randomised controlled clinical trials (RCTs), published until January 2023 in English language and was performed by two independent reviewers. Quality assessment of the included studies was conducted according to the Cochrane Risk of Bias tool. RESULTS The final selection of studies included 11 RCTs. Clinically relevant variables derived from this search were: Complications, with caries being the most frequently reported, periodontal aspects and bone changes around abutment teeth. Additionally, methods and clinical suggestions for the maintenance of these restorations and patient-related outcomes were assessed. According to the risk of bias assessment, nine studies were considered of high risk, whereas only 2 of low risk. A meta-analysis was not feasible. CONCLUSION Within the limitations of this systematic review, ROD remain a viable treatment plan, offering better denture stability and bone preservation around abutment teeth and high patient satisfaction. Thorough oral hygiene and regular follow-ups are of utmost importance. Further well-designed RCTs are necessary for firmer conclusions.
Collapse
Affiliation(s)
- Aspasia Pachiou
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Panagiotis Karakostas
- Department of Preventive Dentistry, Periodontology and Implant Biology, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Panagiotis Roulias
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Olga Naka
- Department of Prosthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
4
|
Hackett S, Newton R, Ali R. Rehabilitating a severely worn dentition with removable prosthodontics. Br Dent J 2023; 234:413-421. [PMID: 36964363 PMCID: PMC10038800 DOI: 10.1038/s41415-023-5583-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 01/08/2023] [Accepted: 01/14/2023] [Indexed: 03/26/2023]
Abstract
In the next part of this series on tooth wear management, we discuss the indications and clinical stages for the provision of removable prostheses for the treatment of severely worn and depleted dentitions. The general design features of a complex prosthesis are described for reorganised occlusal schemes and maintenance guidelines are explained. In addition, the clinical stages for three different situations are described: removable-only approaches, and combined fixed and removable in the same arch and separate arches. The value of providing removable prostheses in worn dentitions allows the immediate rehabilitation of severely worn teeth taking a non-invasive and retrievable approach when the remaining dentition is of poor quality or structure and/or there are missing teeth.
Collapse
Affiliation(s)
- Stephanie Hackett
- Speciality Registrar in Restorative Dentistry, Department of Restorative Dentistry, Liverpool University Dental Hospital, Pembroke Place, Liverpool, L3 5PS, UK.
| | - Richard Newton
- Speciality Registrar in Restorative Dentistry, Department of Restorative Dentistry, Liverpool University Dental Hospital, Pembroke Place, Liverpool, L3 5PS, UK
| | - Rahat Ali
- Consultant in Restorative Dentistry, Department of Restorative Dentistry, Liverpool University Dental Hospital, Pembroke Place, Liverpool, L3 5PS, UK
| |
Collapse
|
5
|
Ettinger RL, Marchini L, Childs CA. Are Root-Supported Overdentures Still an Alternative to Implant-Supported Overdentures? A Scoping Review. J Prosthodont 2022; 31:655-662. [PMID: 35187751 DOI: 10.1111/jopr.13498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 02/14/2022] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To compare the outcomes of prosthodontic treatment for subjects wearing a complete maxillary denture opposing a root-supported mandibular overdenture (RSO) or an implant-supported mandibular overdenture (ISO). METHODS A literature search was performed in seven electronic databases: MEDLINE via PubMed interface, Embase, Cochrane Library, Cumulative Index to Nursing and Allied Health Literature, Scopus, Web of Science, and AgeLine. The search terms were developed by the primary investigators and the health sciences librarian, who then started with PubMed and adapted the original search strategy for the other databases. Included articles were those that compared the outcomes for mandibular RSOs and those with ISOs, for persons wearing a maxillary complete denture. RESULTS Seven articles were included in the review. There were limitations in this review because of small sample sizes, short study durations, and different methodologies. Also, no comparative studies were identified for clinically important outcomes, such as survival rates of abutments, prosthodontics/maintenance problems, and longitudinal cost of care. For prosthodontic complications, patient satisfaction, and ability to clean, no differences were reported. For oral tactile sensibility, RSOs presented significantly improved sensibility, whereas ISOs had higher maximum bite force capability, but the difference was not statistically significant, except when subjects had a cross-bite or a lingualized occlusion. CONCLUSIONS The results of this scoping review were not conclusive, except for maximum bite force, where ISOs seem to perform better than RSOs by the measured criteria. ISOs had higher survival rates than RSOs, and required less maintenance, but were more expensive. It was disappointing to find so few studies comparing these clinical treatment modalities, which suggests that either treatment may be clinically acceptable and depends upon a shared decision between patients and their dentists.
Collapse
Affiliation(s)
- Ronald L Ettinger
- Department of Prosthodontics, the University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA
| | - Leonardo Marchini
- Department of Preventive and Community Dentistry, the University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA
| | - Christopher A Childs
- Clinical Education Librarian, Hardin Library of Health Sciences, the University of Iowa, Iowa City, IA
| |
Collapse
|
6
|
Abdelfattah Mohamed AM, El Homossany MEMB, Abdelmoniem SM, Abdelrahman TY. Comparison of tensile bond strength of ball attachments made of different materials to root canal dentin after chewing simulation. BMC Oral Health 2022; 22:254. [PMID: 35751090 PMCID: PMC9229525 DOI: 10.1186/s12903-022-02282-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 06/10/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Debonding of ball attachments is one of the complications that annoy teeth supported overdenture wearers. The polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) polymers are widely applied in the dental field. The purpose of the current study was to compare the tensile bond strength of ball attachments made of such materials and the commonly used titanium ones after 5 years of overdenture insertion and removal (5000 cycles) in addition to chewing simulation (1,200,000 cycle). METHODS Extracted mandibular canines (N = 60) were randomly allocated into three groups and received ball attachments; titanium (group TI; N = 20), PEEK (group PE; N = 20), PEKK (group PK; N = 20). In each group, the samples were divided into two subgroups whereas tensile bond strength was measured pre aging (T0; n = 10) and post aging (T1; n = 10). Tensile bond strength was measured by the Pull out test using the Universal testing machine. Failure mode analysis was determined by examination of the samples' surfaces under 65X stereomicroscope. The resulting data followed normal distribution and the significance level was set at (α = 0.05). RESULTS One Way Anova showed statistically significant difference between the three groups (P < .00001). PostHoc Tukey test showed statistically significant difference between the groups TI and PE, TI and PK and no statistically significant difference between the groups PE and PK. Paired t test showed statistically significant difference in the tensile bond strength pre and post aging in each group. CONCLUSIONS PEEK and PEKK ball attachments could be concluded to have a higher tensile bond strength compared to the titanium ones when bonded to root dentin. Tensile bond strength of such attachments may decrease with aging as well. Clinically, the higher tensile bond strength may have a lesser rate of debonding and thus reduced patient apprehension.
Collapse
Affiliation(s)
- Ahmed Mostafa Abdelfattah Mohamed
- Oral and Maxilofacial Prosthodontics Department, Faculty of Dentistry, AinShams University, Organization of African Unity Street, Cairo, 11561, Egypt.
| | | | | | | |
Collapse
|
7
|
Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial. Int J Dent 2022; 2022:6947756. [PMID: 35265135 PMCID: PMC8901354 DOI: 10.1155/2022/6947756] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Accepted: 02/02/2022] [Indexed: 11/17/2022] Open
Abstract
Background. Many patients suffer from lack of retention of conventional mandibular overdentures due to loss of clip retention over time. Computer-aided design-computer-aided manufacturing (CAD-CAM) milled polyether ether ketone (PEEK) materials may be used for the construction of retentive housing and clips for improving retention of implant-supported overdentures. Objective. To compare retention and patient satisfaction of implant-supported mandibular overdentures retained by conventional nylon clip and metal housings for ball attachments versus PEEK clip and housings. Methods. Twenty-two participants were divided into 2 equal groups (n = 11). The conventional group received implant-supported mandibular overdentures retained by metal housings and nylon retentive elements, while the PEEK group received implant-supported mandibular overdentures retained by PEEK retentive elements and housings. The PEEK retentive elements were made using computer-aided design and computer-aided manufacturing (CAD-CAM). The evaluation included measuring the retention by applying a gradual pulling up force by force meter and patient satisfaction with a 7-point visual analog scale (VAS) at overdenture insertion and 3, 6, and 12 months subsequently by a research interviewer. Results. The PEEK group showed statistically significantly increased retention force (
) at the time of insertion (37.6/17.79) and after 3 months (33.9/16.78), 6 months (32.7/15.97), and 12 months (31.65/13.05). The conventional group had a statistically significantly higher mean overall satisfaction (
) at the time of insertion (65/82.18). No statistically significant difference was found after 3 months (87.81/84.72). The PEEK group showed statistically significantly higher mean overall satisfaction (
) after 6 months (86.36/80.18) and 12 months (85.45/79.54). Conclusions. According to the results of this study, the PEEK retentive material provided more retention than did the conventional material and led to improved patient satisfaction. The study was registered at clinical trials.gov (https://clinicaltrials.gov/ct2/show/NCT05079048).
Collapse
|
8
|
Sharaf M, Eskander A. Attachment-Retained Unilateral Partial Denture versus Tooth Implant-Supported Prosthesis in Mandibular Distal Extension Cases: A Randomized Controlled Trial. Open Dent J 2021. [DOI: 10.2174/1874210602115010626] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Objective:
To evaluate patients’ satisfaction, biting force measurement, and radiographic evaluation of abutment teeth of tooth implant-supported fixed partial denture, unilateral attachment, and conventional partial denture in mandibular distal extension cases.
Materials and Methods:
Twenty-four participants were selected according to the following criteria: participants with unilateral mandibular distal extension with last standing second premolar abutment; participants having abutments with sufficient occluso-gingival height and good periodontal condition. Participants were divided into the following three equal groups: participants of the implant group received fixed tooth implant-supported fixed partial dentures, attachment group participants received unilateral attachment removable partial dentures, and conventional group participants received conventional removable partial dentures. The evaluation included patient satisfaction using “OHIP14” questionnaires, biting force measurement, and radiographic evaluation of terminal abutments using the ANOVA test.
Results:
Participants of the implant group were mainly satisfied with their prosthesis than the attachment group, which is higher than the conventional. Regarding biting force measurement, there is a statistically significant difference (p < 0.05) between all groups, including the implant group and attachment group, as well as between attachment and conventional group (p < 0.05). The conventional group showed statistically significant (p < 0.05) highest mean bone loss, while there was no statistically significant difference between implant and attachment groups; both showed statistically significantly lower mean amounts of bone loss.
Conclusion:
The tooth implant-supported fixed prosthesis could be considered a superior line of treatment for managing distal extension cases. Unilateral attachment, which is considered an excellent alternative in the case of implant placement, is not recommended.
Collapse
|
9
|
Drago C, Borgert AJ. Comparison of nonscheduled, postinsertion adjustment visits for complete dentures fabricated with conventional and CAD-CAM protocols: A clinical study. J Prosthet Dent 2019; 122:459-466. [DOI: 10.1016/j.prosdent.2018.10.030] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 10/18/2018] [Accepted: 10/18/2018] [Indexed: 10/26/2022]
|
10
|
Fotiou A, Kamalakidis SN, Pissiotis AL, Michalakis K. In vitro investigation of the impact of remaining tooth structure on the tensile failure loads of overdenture copings. J Clin Exp Dent 2019; 11:e1006-e1011. [PMID: 31700574 PMCID: PMC6825728 DOI: 10.4317/jced.56228] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Accepted: 10/07/2019] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The purpose of this in vitro study was to evaluate the impact of the remaining tooth structure on the retention of overdenture cast metal copings. MATERIAL AND METHODS A freshly extracted intact mandibular human canine (length 25 mm) was selected and endodontically treated. An incisal reduction of 4 mm with no ferrule preparation was performed and a post space of 12 mm was created. By using polyvinyl siloxane duplication material and autopolymerizing polymethylmethacrylate resin, ten resin teeth analogs (control group) were obtained. A second set of ten resin teeth analogs (group 1) was created by preparing on the original natural tooth a 360o ferrule design of 1 mm in height and by using the same procedural technique. The canine was further reduced by an additional 1 mm, resulting in a ferrule of 2 mm in height, measured from the initial incisal reduction, thus a third set of ten resin teeth analogs (group 2) was created. For every tooth analog in all groups a dome-shaped metal coping was cast and luted with a glass ionomer cement. All specimens were subjected to tensile load testing until decementation occurred. RESULTS The specimens in the control group exhibited a mean failure load of 87.21 ± 18.26 N, while the 1 mm ferrule group recorded a higher mean failure load of 125.43 ± 8.79 N and the 2 mm ferrule group recorded the highest mean failure load of 146.12 ± 23.38 N. One-way ANOVA revealed significant differences (F= 28.04, p<0.001) in the tensile failure loads between all of the groups being tested. CONCLUSIONS The metal copings with a 2 mm ferrule design exhibited the highest retention values, followed by the 1 mm ferrule and the no ferrule design, with the differences among them being statistically significant. Key words:Ferrule effect, In vitro study, Metal copings, Overdenture, Tensile stress.
Collapse
Affiliation(s)
- Anna Fotiou
- DDS. Resident, Department of Prosthodontics, Aristotle University Faculty of Health Sciences, School of Dentistry, Thessaloniki, Greece
| | - Savvas N Kamalakidis
- DDS, PhD, FACP. Faculty, Department of Prosthodontics, Aristotle University Faculty of Health Sciences, School of Dentistry, Thessaloniki, Greece and Adjunct Assistant Professor, Division of Postgraduate Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass
| | - Argirios L Pissiotis
- DDS, MS, PhD. Professor, Department of Prosthodontics, Aristotle University Faculty of Health Sciences, School of Dentistry, Thessaloniki, Greece
| | - Konstantinos Michalakis
- DDS, MSc, PhD, FACP. Associate Professor and Director of Graduate Prosthodontics, Aristotle University Faculty of Health Sciences, School of Dentistry, Thessaloniki, Greece and Adjunct Associate Professor, Division of Postgraduate Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass
| |
Collapse
|