Han JW, Han JW, Pyo SW, Kim S. Impact of profile angle of CAD-CAM abutment on the marginal bone loss of implant-supported single-tooth posterior restorations.
J Prosthet Dent 2023:S0022-3913(23)00780-1. [PMID:
38129258 DOI:
10.1016/j.prosdent.2023.11.025]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/19/2023] [Accepted: 11/20/2023] [Indexed: 12/23/2023]
Abstract
STATEMENT OF PROBLEM
Although the emergence angle has been related to marginal bone loss, information regarding the relationship between the transmucosal configuration of a computer-aided design and computer-aided manufacturing (CAD-CAM) abutment at specific subgingival levels and the amount of marginal bone loss is lacking.
PURPOSE
The purpose of this retrospective clinical study was to evaluate the influence of CAD-CAM abutment profile angles, measured at different subgingival positions, on the marginal bone loss of posterior single-tooth implant-supported restorations.
MATERIAL AND METHODS
A total of 260 posterior single-tooth implant-supported restorations using CAD-CAM abutments were analyzed in 206 patients. All implants had internal conical seal connections with a platform-switched design. The following data were extracted using digital periapical radiography: emergence profile, profile angle at distance ranges of 0 to 1 mm, 1 to 2 mm, and 2 to 3 mm from the implant-abutment junction, and peri-implant marginal bone loss (MBL). The MBL was measured from the time of delivery of the restorations up to 7 years or more. A linear mixed model was applied to investigate whether there was a significant difference in MBL based on the emergence profile and time, followed by the Bonferroni correction post hoc test. A Pearson correlation analysis was used to analyze the correlation between the profile angle and MBL at each distance range. The cut-off points for each distance range were determined by using the c-index, and independent t tests were conducted based on these cut-off values to evaluate the statistical differences (α=.05 for all statistical analyses).
RESULTS
The convex emergence profile exhibited greater MBL than the concave and straight profiles at each follow-up visit (P<.001). A significant correlation was found between the profile angle and MBL in the 0 to 1 mm, 1 to 2 mm distance ranges. However, no significant correlation was found between the profile angle and MBL in the 2 to 3 mm distance range (P>.05). The cut-off points were 34 degrees at the mesial and 28 degrees at the distal in the 0 to 1 mm range, and 33 and 20 degrees at the mesial and distal in the 1 to 2 mm range.
CONCLUSIONS
The profile angle near the implant-abutment junction and the type of emergence profile of the CAD-CAM abutment were closely associated with MBL in implants with internal conical seal connection with a platform switch design.
Collapse