1
|
Unes M, Kurashima K, Caliskan Y, Portz E, Jain A, Nazzal M. Normothermic ex vivo perfusion of deceased donor kidneys and its clinical potential in kidney transplantation outcomes. Int J Artif Organs 2023; 46:618-628. [PMID: 37897367 DOI: 10.1177/03913988231207719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/30/2023]
Abstract
In recent years, normothermic machine perfusion (NMP) has emerged in conversation surrounding organ preservation and transplantation techniques with the goal of improving patient and clinical outcomes. This is in great attempt to address the rate of non-utilization and the shortage of available organs in kidney transplantation. This focus in mind, normothermic perfusion presents itself as a potential tool to mimic physiological conditions and improve current preservation methods, such as static cold storage. This review serves to improve understanding of the observed connection between the consequences of ischemia and reperfusion injury and traditional preservation techniques as well as how renal NMP may mitigate these issues. Previous studies suggest that reducing time in static cold storage methods by promoting the normothermic perfusion model results in decreased delayed graft function and post-transplant complications. This review also aims to present the immense clinical potential NMP has on future kidney transplantation success and what this means for the fields of nephrology and transplantation. While great strides have been made to evaluate normothermic perfusion's impact on kidney graft viability and transplant success, future research into unified protocol, clinically relevant biomarkers, cost-utility analysis, and use with associated therapeutic and imaging modalities is paramount.
Collapse
Affiliation(s)
| | - Kento Kurashima
- Department of Pediatrics, SSM Saint Louis University School of Medicine, Saint Louis, MO, USA
| | - Yasar Caliskan
- Division of Nephrology, SSM Saint Louis University Hospital, Saint Louis, MO, USA
| | | | - Ajay Jain
- Department of Pediatrics, SSM Saint Louis University School of Medicine, Saint Louis, MO, USA
| | - Mustafa Nazzal
- Department of Surgery, SSM Saint Louis University Hospital, Saint Louis, MO, USA
| |
Collapse
|
2
|
Ghoneima AS, Sousa Da Silva RX, Gosteli MA, Barlow AD, Kron P. Outcomes of Kidney Perfusion Techniques in Transplantation from Deceased Donors: A Systematic Review and Meta-Analysis. J Clin Med 2023; 12:3871. [PMID: 37373568 DOI: 10.3390/jcm12123871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 05/03/2023] [Accepted: 05/09/2023] [Indexed: 06/29/2023] Open
Abstract
The high demand for organs in kidney transplantation and the expansion of the donor pool have led to the widespread implementation of machine perfusion technologies. In this study, we aim to provide an up-to-date systematic review of the developments in this expanding field over the past 10 years, with the aim of answering the question: "which perfusion technique is the most promising technique in kidney transplantation?" A systematic review of the literature related to machine perfusion in kidney transplantation was performed. The primary outcome measure was delayed graft function (DGF), and secondary outcomes included rates of rejection, graft survival, and patient survival rates after 1 year. Based on the available data, a meta-analysis was performed. The results were compared with data from static cold storage, which is still the standard of care in many centers worldwide. A total of 56 studies conducted in humans were included, and 43 studies reported outcomes of hypothermic machine perfusion (HMP), with a DGF rate of 26.4%. A meta-analysis of 16 studies showed significantly lower DGF rates in the HMP group compared to those of static cold storage (SCS). Five studies reported outcomes of hypothermic machine perfusion + O2, with an overall DGF rate of 29.7%. Two studies explored normothermic machine perfusion (NMP). These were pilot studies, designed to assess the feasibility of this perfusion approach in the clinical setting. Six studies reported outcomes of normothermic regional perfusion (NRP). The overall incidence of DGF was 71.5%, as it was primarily used in uncontrolled DCD (Maastricht category I-II). Three studies comparing NRP to in situ cold perfusion showed a significantly lower rate of DGF with NRP. The systematic review and meta-analysis provide evidence that dynamic preservation strategies can improve outcomes following kidney transplantation. More recent approaches such as normothermic machine perfusion and hypothermic machine perfusion + O2 do show promising results but need further results from the clinical setting. This study shows that the implementation of perfusion strategies could play an important role in safely expanding the donor pool.
Collapse
Affiliation(s)
- Ahmed S Ghoneima
- Department of HPB and Transplant Surgery, St. James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds LS9 7TF, UK
| | - Richard X Sousa Da Silva
- Swiss HPB and Transplantation Center, Department of Surgery and Transplantation, University Hospital Zurich, 8091 Zurich, Switzerland
| | | | - Adam D Barlow
- Department of HPB and Transplant Surgery, St. James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds LS9 7TF, UK
| | - Philipp Kron
- Department of HPB and Transplant Surgery, St. James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds LS9 7TF, UK
- Swiss HPB and Transplantation Center, Department of Surgery and Transplantation, University Hospital Zurich, 8091 Zurich, Switzerland
| |
Collapse
|
3
|
Werenski H, Stratta RJ, Sharda B, Garner M, Farney AC, Orlando G, McCracken E, Jay CL. Knowing When to Ignore the Numbers: Single-Center Experience Transplanting Deceased Donor Kidneys with Poor Perfusion Parameters. J Am Coll Surg 2023; 236:848-857. [PMID: 36735482 DOI: 10.1097/xcs.0000000000000611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Hypothermic machine perfusion is frequently used in evaluating marginal kidneys with poor perfusion parameters (PPP) contributing to delays in kidney placement or discard. We examined outcomes in deceased donor kidney transplants with PPP compared with those with optimal perfusion parameters (OPP). STUDY DESIGN We conducted a retrospective single-center cohort study from 2001 to 2021 comparing PPP (n = 91) with OPP (n = 598) deceased donor kidney transplants. PPP was defined as terminal flow ≤80 mL/min and terminal resistance ≥0.40 mmHg/mL/min. OPP was defined as terminal flow ≥120 mL/min and terminal resistance ≤0.20 mmHg/mL/min. RESULTS Mean terminal flow was PPP 66 ± 16 vs OPP 149 ± 21 mL/min and resistance was PPP 0.47 ± 0.10 vs OPP 0.15 ± 0.04 mmHg/mL/min (both p < 0.001). Donor age, donation after cardiac death, and terminal serum creatinine levels were similar between groups. Mean Kidney Donor Profile Index was higher among PPP donors (PPP 65 ± 23% vs OPP 52 ± 27%, p < 0.001). The PPP transplant group had more females and lower weight and BMI. Delayed graft function was comparable (PPP 32% vs OPP 27%, p = 0.33) even though cold ischemia times trended toward longer in PPP kidneys (PPP 28 ± 10 vs OPP 26 ± 9 hours, p = 0.09). One-year patient survival (PPP 98% vs OPP 97%, p = 0.84) and graft survival (PPP 91% vs OPP 92%, p = 0.23) were equivalent. PPP did predict inferior overall and death-censored graft survival long-term (overall hazard ratio 1.63, 95% CI 1.19 to 2.23 and death-censored hazard ratio 1.77, 95% CI 1.15 to 2.74). At 1 year, the estimated glomerular filtration rate was higher with OPP kidneys (PPP 40 ± 17 vs OPP 52 ± 19 mL/min/1.73 m 2 , p < 0.001). CONCLUSIONS Short-term outcomes in PPP kidneys were comparable to OPP kidneys despite higher Kidney Donor Profile Index and longer cold ischemia times, suggesting a role for increased utilization of these organs with careful recipient selection.
Collapse
Affiliation(s)
- Hope Werenski
- From the Department of Surgery, Section of Abdominal Organ Transplantation, Atrium Health Wake Forest Baptist, Winston-Salem, NC
| | | | | | | | | | | | | | | |
Collapse
|
4
|
Rutman AK, Negi S, Saberi N, Khan K, Tchervenkov J, Paraskevas S. Extracellular Vesicles From Kidney Allografts Express miR-218-5p and Alter Th17/Treg Ratios. Front Immunol 2022; 13:784374. [PMID: 35281056 PMCID: PMC8906931 DOI: 10.3389/fimmu.2022.784374] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 02/03/2022] [Indexed: 01/18/2023] Open
Abstract
Delayed graft function (DGF) in kidney transplantation is associated with ischemic injury and carries long term functional and immunological risks. Extracellular vesicles (EV) released from allografts may signal a degree of ischemic stress, and are thought to play an important role in the development of anti-donor immunity. Here, we show that kidney perfusate-derived extracellular vesicles (KP-EV) express donor-specific human leukocyte antigen. KP-EV from kidneys that experience DGF increase the T-helper 17 (Th17) to T-regulatory (Treg) ratio in third party peripheral blood mononuclear cells to a greater degree than those from kidneys with immediate function. We report miR-218-5p upregulation in KP-EV of kidney transplant recipients with DGF. Levels of miR-218-5p in KP-EV inversely correlated with recipient eGFR at multiple time points following transplantation. Additionally, the degree of increase in Th17/Treg ratio by KP-EV positively correlated with miR-218-5p expression in KP-EV samples. Taken together, these data provide evidence that KP-EV may contribute to modulating immune responses in transplant recipients. This could lead to novel intervention strategies to inhibit DGF in order to improve graft function and survival.
Collapse
Affiliation(s)
- Alissa K Rutman
- Department of Surgery, McGill University, Montréal, QC, Canada.,Transplantation Immunology Laboratory, Research Institute of the McGill University Health Centre, Montréal, QC, Canada
| | - Sarita Negi
- Department of Surgery, McGill University, Montréal, QC, Canada.,Transplantation Immunology Laboratory, Research Institute of the McGill University Health Centre, Montréal, QC, Canada
| | - Nasim Saberi
- Department of Surgery, McGill University, Montréal, QC, Canada
| | - Kashif Khan
- Division of Cardiology and Cardiac Surgery, McGill University Health Centre, Montréal, QC, Canada
| | - Jean Tchervenkov
- Department of Surgery, McGill University, Montréal, QC, Canada.,Transplantation Immunology Laboratory, Research Institute of the McGill University Health Centre, Montréal, QC, Canada
| | - Steven Paraskevas
- Department of Surgery, McGill University, Montréal, QC, Canada.,Transplantation Immunology Laboratory, Research Institute of the McGill University Health Centre, Montréal, QC, Canada
| |
Collapse
|
5
|
Choubey AP, Rady EW, Koizumi N, Siddique AB, Wiederhold P, Ortiz J. Disparate Formulations for Machine Perfusion: A Survey of Organ Procurement Organizations' Medication Additives and Outcome Analyses. EXP CLIN TRANSPLANT 2021; 19:1124-1132. [PMID: 34812703 DOI: 10.6002/ect.2021.0037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVES Machine perfusionfor kidney preservation is a common practice. There is no consensus on the best formula for perfusion solutions. We aimed to discern the additives that organ procurement organizations in the United States include in their perfusate and the impact of these additives on transplant outcomes. MATERIALS AND METHODS A telephone survey of all 58 organ procurement organizations in the United States regarding additives to their perfusion solutions was conducted. The survey data were merged with transplant recipient outcome data from the United Network for Organ Sharing database.The final analysis included perfused kidneys between January 2014 and March 2019. Logistic regressions were performed to investigate whether a particular perfusion formula was associated with delayed graft function, primary nonfunction, or early graft failure. RESULTS Additives correlated with decreased rates of graft failure were mannitol in all kidneys and kidneys of lower quality (P < .01) and penicillin/ampicillin in all kidneys (P < .05). Additives associated with increased graft failure regardless of type included verapamil in all kidneys (P < .05) and kidneys of lower quality (P < .01) and arginine with glutathione in all kidneys and low-quality kidneys alone (P < .01). CONCLUSIONS Further outcomes research and standardized guidelines for additives in machine perfusion of kidneys across all organ procurement organizations are needed.
Collapse
Affiliation(s)
- Ankur P Choubey
- From the Department of Surgery, Rutgers Robert Wood Johnson University Hospital, New Brunswick, New Jersey, USA
| | | | | | | | | | | |
Collapse
|
6
|
Abstract
Hypothermic and normothermic machine perfusion in kidney transplantation are purported to exert a beneficial effect on post-transplant outcomes compared to the traditionally used method of static cold storage. Kidney perfusion techniques provide a window for organ reconditioning and quality assessment. However, how best to deliver these preservation methods or improve organ quality has not yet been conclusively defined. This review summarises the promising advances in machine perfusion science in recent years, which have the potential to further improve early graft function and prolong graft survival.
Collapse
|
7
|
Tatsis V, Dounousi E, Mitsis M. Hypothermic Machine Perfusion of Kidney Transplant: A Mini-Review. Transplant Proc 2021; 53:2793-2796. [PMID: 34696905 DOI: 10.1016/j.transproceed.2021.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Most kidney grafts are marginal and from deceased donors, which yield worse clinical outcomes. Hypothermic machine perfusion has created a paradigm shift in kidney preservation. This mini-review summarizes the main points of hypothermic machine perfusion of kidney transplants that should be known by any physician and surgeon involved with kidney transplantation. Specifically, this review explains a proposed mechanism of action of hypothermic machine perfusion of kidney transplants. This review also describes the clinical effectiveness of hypothermic machine perfusion and explains how to evaluate and predict graft functionality according to machine parameters and perfusate biomarkers. Finally, treatment options and the most recent studies on oxygenated hypothermic machine perfusion are mentioned.
Collapse
Affiliation(s)
| | - Evangelia Dounousi
- Department of Nephrology, University Hospital of Ioannina, Ioannina, Greece
| | | |
Collapse
|
8
|
Cherchi V, Baccarani U, Vetrugno L, Pravisani R, Bove T, Meroi F, Terrosu G, Adani GL. Early Graft Dysfunction Following Kidney Transplantation: Can Thermographic Imaging Play a Predictive Role? Semin Cardiothorac Vasc Anesth 2021; 25:196-199. [PMID: 33840293 DOI: 10.1177/10892532211007270] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The shortage of organs and the growing need for them over recent years have led to the adoption of less stringent donor acceptance criteria, resulting in the approval of marginal organs for transplant, especially from elderly donors. This implies a higher risk of graft dysfunction, a higher frequency of immunological and vascular complications, and shorter graft survival. Several strategies have been implemented in clinical practice to assess graft quality and suitability for transplantation. We have started to test the prospective intraoperative use of thermo-vision cameras during graft reperfusion. Images were acquired using the FLIR One Pro thermo-vision camera for android devices. We hypothesized that thermal images would give a better perspective about the quality of arterial perfusion and graft revascularization of the renal cortex. Thermo-vision cameras provide an easy-to-use, noninvasive, cost-effective tool for the global assessment of kidney graft cortical microcirculation in the immediate post-reperfusion period, providing additional data on the immediate viability and function of a graft.
Collapse
Affiliation(s)
- Vittorio Cherchi
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy
| | - Umberto Baccarani
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy.,Department of Medicine, University of Udine, Udine, Italy
| | - Luigi Vetrugno
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy.,Department of Medicine, University of Udine, Udine, Italy
| | - Riccardo Pravisani
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy.,Department of Medicine, University of Udine, Udine, Italy
| | - Tiziana Bove
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy.,Department of Medicine, University of Udine, Udine, Italy
| | - Francesco Meroi
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy.,Department of Medicine, University of Udine, Udine, Italy
| | - Giovanni Terrosu
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy.,Department of Medicine, University of Udine, Udine, Italy
| | - Gian Luigi Adani
- Azienda Sanitaria Universitaria Friuli Centrale, University-Hospital of Udine, Udine, Italy
| |
Collapse
|
9
|
Abstract
PURPOSE OF REVIEW The shortage of kidneys for transplantation has led to an urgent need to efficiently utilize the available cadaveric kidneys. Efficient use of machine perfusion may potentially lead to increased use of marginal kidneys by lowering the incidence of delayed graft function (DGF) and improving graft outcomes. RECENT FINDINGS Machine perfusion has had a resurgence in the last 10-15 years over static cold storage (SCS). Hypothermic machine perfusion (HMP), the most commonly utilized type of machine perfusion reduces the rates of DGF when compared with SCS with a trend towards improving the overall graft survival. SUMMARY Despite reduction in the rates of DGF by HMP, its effect on long-term renal and patient outcomes is not clearly known. There is limited clinical literature in the use of normothermic machine perfusion (NMP) but a few pilot studies have shown its potential to resuscitate commonly discarded kidneys. In addition to preservation, machine perfusion also allows for various diagnostic and therapeutic interventions during the preservation period to assess and optimize the viability of the procured kidney.
Collapse
|
10
|
Wang Z, Durai P, Tiong HY. Expanded criteria donors in deceased donor kidney transplantation - An Asian perspective. Indian J Urol 2020; 36:89-94. [PMID: 32549658 PMCID: PMC7279103 DOI: 10.4103/iju.iju_269_19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 02/26/2020] [Accepted: 02/28/2020] [Indexed: 01/29/2023] Open
Abstract
There is an increasing gulf between demand and supply for kidneys in end-stage renal failure patients worldwide, especially Asia. Renal transplantation is often the treatment of choice for long-suffering patients who have to undergo dialysis on a regular basis. The utilization of expanded criteria donors (ECDs) to address the donor pool shortage has been proven to be a legitimate solution. Metzger first described the classification of standard criteria donor and ECD in 2002. Since then, the criterion has undergone various modifications, with the key aims of optimizing organ procurement rate while minimizing discard and rejection rates. We review the methods to improve selection, characterization of risks, and surgical techniques. Although the ECD kidneys have a higher risk of impaired donor and recipient outcome than the "standard criteria" transplants, it may be justified by the improved overall survival of these patients compared to those who remained on dialysis. It is, therefore, crucial that we perform meticulous selection, along with state of the art surgical techniques to maximize the use of this scarce resource. In this article, we review the pre-procurement and post-procurement processes implemented to preserve outcomes.
Collapse
Affiliation(s)
- Ziting Wang
- Department of Urology, National University Hospital, Singapore
| | - Pradeep Durai
- Department of Urology, National University Hospital, Singapore
| | - Ho Yee Tiong
- Department of Urology, National University Hospital, Singapore
| |
Collapse
|
11
|
Hekmat R, Sturdevant M. A study of the main determinants of kidney allograft long-term survival in the era of new immunosuppressive drugs. SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION 2019; 30:640-647. [PMID: 31249228 DOI: 10.4103/1319-2442.261338] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
The outcome of long-term kidney allograft is extremely important. The present study aimed to discern the factors affecting long-term kidney allograft survival, including the type of donation and the use of extended criteria donors. Seven hundred and thirty-seven kidney transplant alone patients entered this retrospective cross-sectional study. The impact of different factors on death-censored long-term kidney allograft survival was evaluated. The Cox proportional survival model was employed to identify these factors. A value of P < 0.05 was considered statistically significant. The data were analyzed using IBM Statistical Package for the Social Sciences version 19.0. The study was conducted at the Mashhad University of Medical Sciences, Mashhad, Iran. In comparison with living kidney donations, both nontraumatic and traumatic brain death cadaveric kidney donations showed statistically significant inferior graft survival. Furthermore, the Kaplan-Meier survival analysis showed better durability of living kidney donations in comparison with traumatic and nontraumatic deceased donors (Log-rank test value = 0.001). Patients with delayed graft function (DGF) had a significantly shorter long-term death censured long-term graft survival in comparison with those without this complication. The Cox proportional models showed that DGF occurrence and the type of donation play a statistically significant role in long-term kidney graft survival. In addition, regarding graft survival, there was no difference between standard criteria and extended criteria donors. The occurrence of DGF and living or deceased types of donations have a significant effect on long-term kidney allograft survival.
Collapse
Affiliation(s)
- Reza Hekmat
- Department of Nephrology, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mark Sturdevant
- Department of Nephrology, Starzel Institute of Transplantation, Pittsburg University, Pittsburgh, PA, USA
| |
Collapse
|
12
|
|