López-Muñoz A, López-Castaño I, Torres-Parejo Ú, García-Romera MC. A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers. Life (Basel) 2023; 13:2313. [PMID: 38137914 PMCID: PMC10744429 DOI: 10.3390/life13122313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/01/2023] [Accepted: 12/06/2023] [Indexed: 12/24/2023] Open
Abstract
The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST® (CST, Oculus Optikgeräte GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed on twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range. Five device-specific biomechanical parameters, the central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) were measured prior to fitting and one month after CL wear. Differences between the means of the deflection amplitude ratio (DA Ratio) and the standard deviation of the DA Ratio (SD DA Ratio) pre- and post-CL wear were found to be significant (p value = 0.002 in both cases). Significant differences were found between pre- and post-CL wear values in CCT (p value = 0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that the fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CL wear in the assessment of bIOP.
Collapse
Affiliation(s)
- Alfredo López-Muñoz
- Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain; (I.L.-C.); (M.-C.G.-R.)
- Research & Development Department (Miranza Virgen de Luján®), Ophthalmology Center, 41011 Seville, Spain
| | - Isabel López-Castaño
- Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain; (I.L.-C.); (M.-C.G.-R.)
| | - Úrsula Torres-Parejo
- Department of Statistics and Operations Research, University of Grenade, 18071 Grenade, Spain;
| | - Marta-C. García-Romera
- Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain; (I.L.-C.); (M.-C.G.-R.)
| |
Collapse
|
2
|
Pérez-Corral J, Cardona G, Piñero DP, Barroso D, Armadans L. Short- and mid-term changes in CORVIS ST parameters in successful, adult orthokeratology patients. Clin Exp Optom 2023; 106:726-733. [PMID: 36375143 DOI: 10.1080/08164622.2022.2140031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 07/12/2022] [Accepted: 10/20/2022] [Indexed: 11/16/2022] Open
Abstract
CLINICAL RELEVANCE The changes in various biomechanical and tomographic characteristics of the cornea associated with orthokeratology may allow us to identify potential mid- and long-term structural alterations, resulting in a better understanding of the governing mechanisms of this procedure and in its optimisation. BACKGROUND The study aimed at describing short and mid-term changes in CORVIS ST® parameters and indices in orthokeratology (ortho-k), and their diurnal variations. METHODS A prospective observational study was designed in which several CORVIS ST® parameters of 75 new adult participants successfully fitted with overnight ortho-k Seefree® (Conóptica - Hecht Contactlinsen) contact lenses were explored. Measurements were conducted in baseline (BL) conditions and in the morning and evening at the one-night (1 NM/1NT), one-week (1WM/1 WT) and 3-month (3 MM/3MT) follow-up visits. RESULTS Statistically significant differences were found in DARatio_2 mm, IntRad, ARTh, CBI and TBI following overnight ortho-k, when compared with BL values, with most values reaching stability at 1WM or reverting to BL values at 3 MM. The ARTh and CBI parameters showed some of the most significant temporal variations (both p < 0.001), probably reflecting the encountered differences in central corneal thickness between BL and 1WM (p = 0.010) and between BL and 3 MM (p = 0.016). In general, corneal rigidity was higher in the morning at all follow-up visits, and decreased during the day. No statistically significant changes in adjusted intraocular pressure values were found. CONCLUSION Ortho-k in adults may be considered a safe procedure in terms of short and mid-term changes in CORVIS ST® parameters. The observed alterations in most of the parameters provided by the Corvis ST® probably responded to the well-described changes in corneal pachymetry and tomography, rather than to actual alterations in corneal rigidity.
Collapse
Affiliation(s)
- Joan Pérez-Corral
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - Genis Cardona
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - David Barroso
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - Laura Armadans
- School of Optics and Optometry, Department of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| |
Collapse
|
3
|
Lan G, Shi Q, Wang Y, Ma G, Cai J, Feng J, Huang Y, Gu B, An L, Xu J, Qin J, Twa MD. Spatial Assessment of Heterogeneous Tissue Natural Frequency Using Micro-Force Optical Coherence Elastography. Front Bioeng Biotechnol 2022; 10:851094. [PMID: 35360399 PMCID: PMC8962667 DOI: 10.3389/fbioe.2022.851094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 02/28/2022] [Indexed: 11/20/2022] Open
Abstract
Analysis of corneal tissue natural frequency was recently proposed as a biomarker for corneal biomechanics and has been performed using high-resolution optical coherence tomography (OCT)-based elastography (OCE). However, it remains unknown whether natural frequency analysis can resolve local variations in tissue structure. We measured heterogeneous samples to evaluate the correspondence between natural frequency distributions and regional structural variations. Sub-micrometer sample oscillations were induced point-wise by microliter air pulses (60–85 Pa, 3 ms) and detected correspondingly at each point using a 1,300 nm spectral domain common path OCT system with 0.44 nm phase detection sensitivity. The resulting oscillation frequency features were analyzed via fast Fourier transform and natural frequency was characterized using a single degree of freedom (SDOF) model. Oscillation features at each measurement point showed a complex frequency response with multiple frequency components that corresponded with global structural features; while the variation of frequency magnitude at each location reflected the local sample features. Silicone blocks (255.1 ± 11.0 Hz and 249.0 ± 4.6 Hz) embedded in an agar base (355.6 ± 0.8 Hz and 361.3 ± 5.5 Hz) were clearly distinguishable by natural frequency. In a beef shank sample, central fat and connective tissues had lower natural frequencies (91.7 ± 58.2 Hz) than muscle tissue (left side: 252.6 ± 52.3 Hz; right side: 161.5 ± 35.8 Hz). As a first step, we have shown the possibility of natural frequency OCE methods to characterize global and local features of heterogeneous samples. This method can provide additional information on corneal properties, complementary to current clinical biomechanical assessments, and could become a useful tool for clinical detection of ocular disease and evaluation of medical or surgical treatment outcomes.
Collapse
Affiliation(s)
- Gongpu Lan
- School of Physics and Optoelectronic Engineering, Foshan University, Foshan, China
- Innovation and Entrepreneurship Teams of Guangdong Pearl River Talents Program, Weiren Meditech Co., Ltd., Foshan, China
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, Foshan University, Foshan, China
- *Correspondence: Gongpu Lan, ; Michael D. Twa,
| | - Qun Shi
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Yicheng Wang
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Guoqin Ma
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Jing Cai
- School of Physics and Optoelectronic Engineering, Foshan University, Foshan, China
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, Foshan University, Foshan, China
| | - Jinping Feng
- Institute of Engineering and Technology, Hubei University of Science and Technology, Xianning, China
| | - Yanping Huang
- School of Physics and Optoelectronic Engineering, Foshan University, Foshan, China
- Innovation and Entrepreneurship Teams of Guangdong Pearl River Talents Program, Weiren Meditech Co., Ltd., Foshan, China
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, Foshan University, Foshan, China
| | - Boyu Gu
- School of Computer and Information Engineering, Tianjin Chengjian University, Tianjin, China
| | - Lin An
- Innovation and Entrepreneurship Teams of Guangdong Pearl River Talents Program, Weiren Meditech Co., Ltd., Foshan, China
| | - Jingjiang Xu
- School of Physics and Optoelectronic Engineering, Foshan University, Foshan, China
- Innovation and Entrepreneurship Teams of Guangdong Pearl River Talents Program, Weiren Meditech Co., Ltd., Foshan, China
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, Foshan University, Foshan, China
| | - Jia Qin
- Innovation and Entrepreneurship Teams of Guangdong Pearl River Talents Program, Weiren Meditech Co., Ltd., Foshan, China
| | - Michael D. Twa
- College of Optometry, University of Houston, Houston, TX, United States
- *Correspondence: Gongpu Lan, ; Michael D. Twa,
| |
Collapse
|
4
|
Tian L, Zhang D, Guo L, Qin X, Zhang H, Zhang H, Jie Y, Li L. Comparisons of corneal biomechanical and tomographic parameters among thin normal cornea, forme fruste keratoconus, and mild keratoconus. EYE AND VISION 2021; 8:44. [PMID: 34784958 PMCID: PMC8596950 DOI: 10.1186/s40662-021-00266-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Accepted: 10/23/2021] [Indexed: 12/27/2022]
Abstract
Background To compare the dynamic corneal response (DCR) and tomographic parameters of thin normal cornea (TNC) with thinnest corneal thickness (TCT) (≤ 500 µm), forme fruste keratoconus (FFKC) and mild keratoconus (MKC) had their central corneal thickness (CCT) matched by Scheimpflug imaging (Pentacam) and corneal visualization Scheimpflug technology (Corvis ST). Methods CCT were matched in 50 eyes with FFKC, 50 eyes with MKC, and 53 TNC eyes with TCT ≤ 500 µm. The differences in DCR and tomographic parameters among the three groups were compared. The receiver operating characteristic (ROC) curve was used to analyze the diagnostic significance of these parameters. Back propagation (BP) neural network was used to establish the keratoconus diagnosis model. Results Fifty CCT-matched FFKC eyes, 50 MKC eyes and 50 TNC eyes were included. The age and biomechanically corrected intraocular pressure (bIOP) did not differ significantly among the three groups (all P > 0.05). The index of height asymmetry (IHA) and height decentration (IHD) differed significantly among the three groups (all P < 0.05). IHD also had sufficient strength (area under the ROC curves (AUC) > 0.80) to differentiate FFKC and MKC from TNC eyes. Partial DCR parameters showed significant differences between the MKC and TNC groups, and the deflection amplitude of the first applanation (A1DA) showed a good potential to differentiate (AUC > 0.70) FFKC and MKC from TNC eyes. Diagnosis model by BP neural network showed an accurate diagnostic efficiency of about 91%. Conclusions The majority of the tomographic and DCR parameters differed among the three groups. The IHD and partial DCR parameters assessed by Corvis ST distinguished FFKC and MKC from TNC when controlled for CCT.
Collapse
Affiliation(s)
- Lei Tian
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.,Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University & Capital Medical University, Beijing Tongren Hospital, Beijing, 100730, China
| | - Di Zhang
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China.,School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China
| | - Lili Guo
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China
| | - Xiao Qin
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China.,School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China
| | - Hui Zhang
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China.,School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China
| | - Haixia Zhang
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China.,School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China
| | - Ying Jie
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
| | - Lin Li
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China. .,School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China.
| |
Collapse
|
5
|
Alteration of corneal biomechanical properties in patients with dry eye disease. PLoS One 2021; 16:e0254442. [PMID: 34252118 PMCID: PMC8274861 DOI: 10.1371/journal.pone.0254442] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 06/27/2021] [Indexed: 11/27/2022] Open
Abstract
Purpose To evaluate the association between symptoms and signs of dry eye diseases (DED) with corneal biomechanical parameters. Methods This cross-sectional study enrolled 81 participants without history of ocular hypertension, glaucoma, keratoconus, corneal edema, contact lens use, diabetes, and ocular surgery. All participants were evaluated for symptoms and signs of DED using OSDI questionnaire, tear film break-up time (TBUT), conjunctival and corneal staining (NEI grading) and Schirmer test. Corneal biomechanical parameters were obtained using Corvis ST. Mixed-effects linear regression analysis was used to determine the association between symptoms and signs of DED with corneal biomechanical parameters. Difference in corneal biomechanical parameter between participants with low (Schirmer value ≤10 mm; LT group) and normal (Schirmer value >10mm; NT group) tear production was analyzed using ANCOVA test. Results The median OSDI scores, TBUT, conjunctival and corneal staining scores as well as Schirmer test were 13±16.5 (range; 0–77), 5.3±4.2 seconds (range; 1.3–11), 0±1 (range; 0–4), 0±2 (ranges; 0–9) and 16±14 mm (range; 0–45) respectively. Regression analysis adjusted with participants’ refraction, intraocular pressure, and central corneal thickness showed that OSDI had a negative association with highest concavity radius (P = 0.02). The association between DED signs and corneal biomechanical parameters were found between conjunctival staining scores with second applanation velocity (A2V, P = 0.04), corneal staining scores with second applanation length (A2L, P = 0.01), Schirmer test with first applanation time (A1T, P = 0.04) and first applanation velocity (P = 0.01). In subgroup analysis, there was no difference in corneal biomechanical parameters between participants with low and normal tear production (P>0.05). The associations were found between OSDI with time to highest concavity (P<0.01) and highest displacement of corneal apex (HC-DA, P = 0.04), conjunctival staining scores with A2L (P = 0.01) and A2V (P<0.01) in LT group, and Schirmer test with A1T (P = 0.02) and HC-DA (P = 0.03), corneal staining scores with A2L (P<0.01) in NT group. Conclusions According to in vivo observation with Corvis ST, patients with DED showed more compliant corneas. The increase in dry eye severity was associated with the worsening of corneal biomechanics in both patients with low and normal tear production.
Collapse
|