Verhemel S, Nuis RJ, van den Dorpel M, Adrichem R, de Sá Marchi MF, Hirsch A, Daemen J, Budde RPJ, Van Mieghem NM. Computed tomography to predict pacemaker need after transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr 2024; 18:597-608. [PMID: 39299898 DOI: 10.1016/j.jcct.2024.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 08/30/2024] [Accepted: 08/31/2024] [Indexed: 09/22/2024]
Abstract
Transcatheter aortic valve replacement (TAVR) is preferred therapy for elderly patients with severe aortic stenosis (AS) and increasingly used in younger patient populations with good safety and efficacy outcomes. However, cardiac conduction abnormalities remain a frequent complication after TAVR ranging from relative benign interventriculair conduction delays to prognostically relevant left bundle branch block and complete atrio-ventricular (AV) block requiring permanent pacemaker implantation (PPI). Although clinical, procedural and electrocardiographic factors have been identified as predictors of this complication, there is a need for advanced strategies to control the burden of conduction defects particularly as TAVR shifts towards younger populations. This state of the art review highlights the value of ECG-synchronized computed tomographic angiography (CTA) evaluation of the aortic root to better understand and manage conduction problems post-TAVR. An update on CTA derived anatomic features related to conduction issues is provided and complemented with computational framework modelling. This CTA-derived 3-dimensional anatomical reconstruction tool generates patient-specific TAVR simulations enabling operators to adapt procedural strategy and implantation technique to mitigate conduction abnormality risks.
Collapse
Affiliation(s)
- Sarah Verhemel
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Rutger-Jan Nuis
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Mark van den Dorpel
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Rik Adrichem
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands
| | | | - Alexander Hirsch
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Joost Daemen
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Ricardo P J Budde
- Department of Radiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Nicolas M Van Mieghem
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands.
| |
Collapse
|
2
|
Kroon HG, Hokken T, van Wiechen M, Ooms JFW, van Gils L, Kardys I, Daemen J, De Jaegere PPT, Nuis RJ, Van Mieghem NM. Conduction dynamics over time after transcatheter aortic valve replacement: An expert review. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2024:S1553-8389(24)00625-0. [PMID: 39299841 DOI: 10.1016/j.carrev.2024.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 07/27/2024] [Accepted: 08/13/2024] [Indexed: 09/22/2024]
Abstract
New conduction disorders remain a frequent complication in current transcatheter aortic valve replacement (TAVR) era. Left bundle branch block (LBBB) occurs early in about 20-30 % of TAVR-patients, persists at 1 month in about 35-45 % of cases and will likely remain thereafter. Third-degree atrioventricular block (AV3B) affects approximately 15 % of patients. Pacemaker dependency gradually decreases throughout follow-up and approximately 25-35 % of patients remain pacemaker dependent at one year. We aimed to review what is currently known about the dynamics of acquired conduction disorders, including extraction of predictors, and how to interpret these dynamics in light of an early discharge policy.
Collapse
Affiliation(s)
- Herbert G Kroon
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Thijmen Hokken
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Maarten van Wiechen
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Joris F W Ooms
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Lennart van Gils
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Isabella Kardys
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Joost Daemen
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Peter P T De Jaegere
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Rutger-Jan Nuis
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Nicolas M Van Mieghem
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands.
| |
Collapse
|
3
|
Ananwattanasuk T, Atreya AR, Teerawongsakul P, Ghannam M, Lathkar-Pradhan S, Latchamsetty R, Jame S, Patel HJ, Grossman PM, Oral H, Jongnarangsin K. Outcomes in patients with electrocardiographic left ventricular dyssynchrony following transcatheter aortic valve replacement. Heart Rhythm 2023; 20:22-28. [PMID: 35948202 DOI: 10.1016/j.hrthm.2022.08.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/28/2022] [Accepted: 08/01/2022] [Indexed: 01/10/2023]
Abstract
BACKGROUND Left bundle branch block (LBBB) and atrioventricular (AV) conduction abnormalities requiring permanent pacemaker (PPM) implantation occur frequently following transcatheter aortic valve replacement (TAVR). The resultant left ventricular (LV) dyssynchrony may be associated with adverse clinical events. OBJECTIVES The purpose of this study was to assess the adverse outcomes associated with LV dyssynchrony due to high-burden right ventricular (RV) pacing or permanent LBBB following TAVR in patients with preserved left ventricular ejection fraction (LVEF). METHODS Consecutive TAVR patients at the University of Michigan from January 2012 to June 2017 were included. Pre-existing cardiac implantable electronic device, previous LBBB, LVEF <50%, or follow-up period <1 year were excluded. The primary outcome was all-cause mortality. Secondary outcomes included cardiomyopathy (defined as LVEF ≤45%), a composite endpoint of cardiomyopathy or all-cause mortality, and the change in LVEF at 1-year follow-up. RESULTS A total of 362 patients were analyzed (mean age 77 years). LV dyssynchrony group (n = 91 [25.1%]) included 56 permanent LBBB patients, 12 permanent LBBB patients with PPM, and 23 non-LBBB patients with PPM and high-burden RV pacing. Remaining patients served as control (n = 271 [74.9%]). After adjusted analysis, LV dyssynchrony had significantly higher all-cause mortality (adjusted hazard ratio [HR] 2.16; 95% confidence interval [CI] 1.07-4.37) and cardiomyopathy (adjusted HR 14.80; 95% CI 6.31-14.69). The LV dyssynchrony group had mean LVEF decline of 10.5% ± 10.2% compared to a small increase (0.5% ± 7.7%) in control. CONCLUSION Among TAVR patients with preserved LVEF and normal AV conduction, development of postprocedural LV dyssynchrony secondary to high-burden RV pacing or permanent LBBB was associated with significantly higher risk of death and cardiomyopathy at 1-year follow-up.
Collapse
Affiliation(s)
- Teetouch Ananwattanasuk
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan; Cardiology Division, Department of Internal Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Thailand
| | - Auras R Atreya
- Institute of Cardiac Sciences and Research, AIG Hospitals, Gachibowli, Hyderabad, India
| | - Padoemwut Teerawongsakul
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan; Cardiology Division, Department of Internal Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Thailand
| | - Michael Ghannam
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan
| | - Sangeeta Lathkar-Pradhan
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan
| | - Rakesh Latchamsetty
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan
| | - Sina Jame
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan
| | - Himanshu J Patel
- Department of Cardiac Surgery, Michigan Medicine, University of Michigan, Ann Arbor, Michigana
| | - Paul Michael Grossman
- Division of Interventional Cardiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan
| | - Hakan Oral
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan
| | - Krit Jongnarangsin
- Division of Cardiac Electrophysiology, Michigan Medicine, University of Michigan, Ann Arbor, Michigan.
| |
Collapse
|
4
|
Ravaux JM, Di Mauro M, Vernooy K, Kats S, Mariani S, Ronco D, Actis Dato G, Simons J, Hof AWV, Maessen JG, Lorusso R. Permanent pacemaker implantation following transcatheter aortic valve implantation using self-expandable, balloon-expandable, or mechanically expandable devices: a network meta-analysis. Europace 2021; 23:1998-2009. [PMID: 34379760 DOI: 10.1093/europace/euab209] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 07/17/2021] [Indexed: 11/13/2022] Open
Abstract
AIMS Permanent pacemaker implantation (PPI) still limits the expansion of indications for transcatheter aortic valve implantation (TAVI). Comparison between different systems remains scarce. We aimed to determine the impact of the device type used on post-TAVI PPI. METHODS AND RESULTS A systematic literature review was performed to identify studies reporting the use of balloon-expandable valve (BEV), self-expandable valve (SEV), and mechanically expandable valve (MEV) and post-TAVI PPI. A network meta-analysis was used to compare TAVI mechanisms (Analysis A) and transcatheter heart valves (Analysis B) with respect to post-TAVI PPI. Analysis A included 40 181 patients with a pooled PPI rate of 19.2% in BEV, 24.7% in SEV, and 34.8% in MEV. Balloon-expandable valve showed lower risk compared to either SEV or MEV and SEV demonstrated lower risk for PPI than MEV. Implantation of BEV was associated with 39% and 62% lower PPI rate with respect to SEV and MEV. Implantation of SEV was associated with 38% lower PPI rate with respect to MEV. Analysis B included 36.143 patients with the lowest pooled PPI rate of 9.6% for Acurate Neo or others, and the highest pooled PPI rate of 34.3% for Lotus. CoreValve, Evolut Portico, and Lotus influenced significantly PPI rate, while Sapien group did not. CONCLUSION Implantation of BEV and also SEV were associated with lower post-TAVI PPI rate, while MEV were associated with higher post-TAVI PPI. Patient tailored-approach including devices characteristics may help to reduce post-TAVI PPI and to allow TAVI to take the leap towards extension of use in younger patients. PROSPERO NUMBER CRD42021238671.
Collapse
Affiliation(s)
- Justine M Ravaux
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands
| | - Michele Di Mauro
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands
| | - Kevin Vernooy
- Department of Cardiology, Maastricht University Medical Centre (MUMC), Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands.,Department of Cardiology, Radboud University Medical Center (Radboudumc), Nijmegen, the Netherlands
| | - Suzanne Kats
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands
| | - Silvia Mariani
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands
| | - Daniele Ronco
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands.,Department of Medicine and Surgery, Circolo Hospital, University of Insubria, Varese, Italy
| | - Giulia Actis Dato
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands
| | - Jorik Simons
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands
| | - Arnoud W Van't Hof
- Department of Cardiology, Maastricht University Medical Centre (MUMC), Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Jos G Maessen
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Roberto Lorusso
- Departement of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
5
|
Ravaux JM, Di Mauro M, Vernooy K, Van't Hof AW, Veenstra L, Kats S, Maessen JG, Lorusso R. One-year pacing dependency after pacemaker implantation in patients undergoing transcatheter aortic valve implantation: Systematic review and meta-analysis. JTCVS OPEN 2021; 6:41-55.e15. [PMID: 36003550 PMCID: PMC9390410 DOI: 10.1016/j.xjon.2021.02.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 02/09/2021] [Indexed: 12/04/2022]
Abstract
Objectives Atrioventricular conductions disturbances, requiring permanent pacemaker implantation (PPI), represent a potential complication after transcatheter aortic valve implantation (TAVI), However, little is known about the pacemaker dependency after PPI in this patient setting. This systematic review analyses the incidence of PPI, the short-term (1-year) pacing dependency, and predictors for such a state after TAVI. Methods We performed a systematic search in PUBMED, EMBASE, and MEDLINE to identify potentially relevant literature investigating PPI requirement and dependency after TAVI. Study data, patients, and procedural characteristics were extracted. Odds ratio (OR) with 95% confidence intervals were extracted. Results Data from 23 studies were obtained that included 18,610 patients. The crude incidence of PPI after TAVI was 17% (range, 8.8%-32%). PPI occurred at a median time of 3.2 days (range, 0-30 days). Pacing dependency at 1-year was 47.5% (range, 7%-89%). Self-expandable prosthesis (pooled OR was 2.14 [1.15-3.96]) and baseline right bundle branch block (pooled OR was 2.01 [1.06-3.83]) showed 2-fold greater risk to maintain PPI dependency at 1 year after TAVI. Conclusions Although PPI represents a rather frequent event after TAVI, conduction disorders have a temporary nature in almost 50% of the cases with recovery and stabilization after discharge. Preoperative conduction abnormality and type of TAVI are associated with higher PPI dependency at short term.
Collapse
Affiliation(s)
- Justine M. Ravaux
- Department of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
- Address for reprints: Justine M. Ravaux, MD, Department of Cardio-Thoracic Surgery, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC+), Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, P. Debyelaan, 25, 6202 AZ Maastricht, The Netherlands.
| | - Michele Di Mauro
- Department of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
| | - Kevin Vernooy
- Department of Cardiology, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
- Department of Cardiology, Radboud University Medical Center (Radboudumc), Nijmegen, The Netherlands
| | - Arnoud W. Van't Hof
- Department of Cardiology, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
| | - Leo Veenstra
- Department of Cardiology, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
| | - Suzanne Kats
- Department of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
| | - Jos G. Maessen
- Department of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
| | - Roberto Lorusso
- Department of Cardio-Thoracic Surgery, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands
| |
Collapse
|