1
|
Calvert P, Ding WY, Griffin M, Bisson A, Koniari I, Fitzpatrick N, Snowdon R, Modi S, Luther V, Mahida S, Waktare J, Borbas Z, Ashrafi R, Todd D, Gupta D. Silent pulmonary veins at redo ablation for atrial fibrillation: Implications and approaches. J Interv Card Electrophysiol 2024; 67:1181-1189. [PMID: 38261098 PMCID: PMC11289157 DOI: 10.1007/s10840-024-01750-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 01/14/2024] [Indexed: 01/24/2024]
Abstract
BACKGROUND Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Despite promising success rates, redo ablation is sometimes required. At redo, PVs may be found to be isolated (silent) or reconnected. We studied patients with silent vs reconnected PVs at redo and analysed associations with adverse outcomes. METHODS Patients undergoing redo AF ablations between 2013 and 2019 at our institution were included and stratified into silent PVs or reconnected PVs. The primary outcome was a composite of further redo ablation, non-AF ablation, atrioventricular nodal ablation, and death. Secondary outcomes included arrhythmia recurrence. RESULTS A total of 467 patients were included with mean 4.6 ± 1.7 years follow-up, of whom 48 (10.3%) had silent PVs. The silent PV group had had more often undergone >1 prior ablation (45.8% vs 9.8%; p<0.001), had more persistent AF (62.5% vs 41.1%; p=0.005) and had more non-PV ablation performed both at prior ablation procedures and at the analysed redo ablation. The primary outcome occurred more frequently in those with silent PVs (25% vs 13.8%; p=0.053). Arrhythmia recurrence was also more common in the silent PV group (66.7% vs 50.6%; p=0.047). After multivariable adjustment, female sex (aHR 2.35 [95% CI 2.35-3.96]; p=0.001) and ischaemic heart disease (aHR 3.21 [95% CI 1.56-6.62]; p=0.002) were independently associated with the primary outcome, and left atrial enlargement (aHR 1.58 [95% CI 1.20-2.08]; p=0.001) and >1 prior ablation (aHR 1.88 [95% CI 1.30-2.72]; p<0.001) were independently associated with arrhythmia recurrence. Whilst a finding of silent PVs was not itself significant after multivariable adjustment, this provides an easily assessable parameter at clinically indicated redo ablation which informs the clinician of the likelihood of a worse future prognosis. CONCLUSIONS Patients with silent PVs at redo AF ablation have worse clinical outcomes.
Collapse
Affiliation(s)
- Peter Calvert
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Wern Yew Ding
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Michael Griffin
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Arnaud Bisson
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
- Centre Hospitalier Régional Universitaire et Faculté de Médecine de Tours, Tours, France
| | - Ioanna Koniari
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Noel Fitzpatrick
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Richard Snowdon
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Simon Modi
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Vishal Luther
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Saagar Mahida
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Johan Waktare
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Zoltan Borbas
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Reza Ashrafi
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Derick Todd
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Dhiraj Gupta
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK.
- Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK.
- Department of Cardiology, Liverpool Heart & Chest Hospital, Thomas Drive, Liverpool, L14 3PE, UK.
| |
Collapse
|
2
|
Kisling AJ, Symons JG, Daubert JP. Catheter ablation of atrial fibrillation: anticipating and avoiding complications. Expert Rev Med Devices 2023; 20:929-941. [PMID: 37691572 DOI: 10.1080/17434440.2023.2257131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 09/06/2023] [Indexed: 09/12/2023]
Abstract
INTRODUCTION Atrial fibrillation (AF) ablation is being performed more frequently and more widely at more centers. This stems from several factors including 1) demographic forces leading to an increased prevalence of the arrhythmia; 2) greater availability of ambulatory monitoring making diagnosis more frequent; 3) relative inefficacy of medications; and 4) improved safety and efficacy of the procedure. Ablation has become much more streamlined and reproducible than a decade ago, but life-threatening complications may still arise. AREAS COVERED This review will focus on awareness, avoidance, and early recognition and management of complications of AF ablation. This literature review is challenged by differing approaches to ablation of AF both within a center and between centers, the rapid improvement of technology making the outcomes associated with a therapeutic strategy begun a few years prior relatively obsolete, as well as the heterogeneity of the population being studied. EXPERT OPINION Newer technologies are on the horizon which will allow us to ablate AF with increasing efficacy, efficiency, and hopefully safety. Such new technology and changing usage mandate vigilance to avoid complications.
Collapse
Affiliation(s)
- Adam J Kisling
- Walter Reed National Military Medical Center, Department of Cardiology, Bethesda, MD, United States of America
| | - John G Symons
- Walter Reed National Military Medical Center, Department of Electrophysiology, Bethesda, MD, United States of America
| | - James P Daubert
- Electrophysiology Section/Duke Center for Atrial Fibrillation, Division of Cardiology, Duke Clinical Research Institute, Department of Medicine, Duke University, Durham, NC, United States of America
| |
Collapse
|