1
|
Liu X, Tan X, Zhang Q, Qiao L, Shi L. A Randomized Crossover Comparison of Airway Sealing with the Laryngeal Mask Airway Ambu AuraFlex at Three Intracuff Pressures in Pediatric Laparoscopic Surgery. Am J Perinatol 2021; 38:231-236. [PMID: 31529447 DOI: 10.1055/s-0039-1696643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVE An adequate intracuff pressure is important to ensure sufficient sealing function when using supraglottic airway devices to protect the airway from secretions and achieve adequate positive pressure ventilation. The aim of this study is to analyze a feasible and effective alternative Ambu AuraFlex intracuff pressure in child's laparoscopic surgery. STUDY DESIGN Seventy-two children were included in this study. After insertion of the laryngeal mask airway AuraFlex, oropharyngeal leak pressure (OLP) was measured at intracuff pressures of 10, 30, and 60-cmH2O according to one of six sequences produced on the basis of 3 × 6 Williams crossover design. During the intraoperative period, AuraFlex was maintained using the last intracuff pressure of the allocated sequence. Oropharyngeal leak pressure, peak airway pressure, the fiberoptic view, mucosal change, and complications were assessed at three intracuff pressures. RESULTS The OLP at the intracuff pressure of 10 cmH2O was significantly lower than that of 30 cmH2O (2# 18.1 ± 1.5 vs. 19.5 ± 1.4 cmH2O, p = 0.001; 2.5# 17.7 ± 1.2 vs. 20.2 ± 1.4, p = 0.001) and 60 cmH2O (2# 18.1 ± 1.5 vs. 20.0 ± 1.3 cmH2O, p = 0.002; 2.5# 17.7 ± 1.2 vs. 20.8 ± 1.1, p = 0.003). Compared with the peak airway pressure in pre-and postpneumoperitoneum, the OLP was significantly higher. Subgroup analysis showed no differences in mucosal change and complications. CONCLUSION Intracuff pressures of 30 may be sufficient for the Ambu AuraFlex in child's laparoscopic surgery, and there may be no added benefit of an intracuff pressure of 60 cmH2O, as oropharyngeal leak pressures were similar.
Collapse
Affiliation(s)
- Xiang Liu
- Department of Anesthesiology, Hebei Medical University Affiliated Children's Hospital of Hebei Province, Shi Jiazhuang, China
| | - Xiaona Tan
- Department of Neurological Rehabilitation, Hebei Medical University Affiliated Children's Hospital of Hebei Province, Shi Jiazhuang, China
| | - Qi Zhang
- Department of Anesthesiology, Hebei Medical University Affiliated Children's Hospital of Hebei Province, Shi Jiazhuang, China
| | - Li Qiao
- Department of Anesthesiology, Hebei Medical University Affiliated Children's Hospital of Hebei Province, Shi Jiazhuang, China
| | - Lei Shi
- Department of Anesthesiology, Hebei Medical University Affiliated Children's Hospital of Hebei Province, Shi Jiazhuang, China
| |
Collapse
|
2
|
Evaluation of Different Positive End-Expiratory Pressures Using Supreme™ Airway Laryngeal Mask during Minor Surgical Procedures in Children. ACTA ACUST UNITED AC 2020; 56:medicina56100551. [PMID: 33096743 PMCID: PMC7589667 DOI: 10.3390/medicina56100551] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 10/09/2020] [Accepted: 10/19/2020] [Indexed: 11/29/2022]
Abstract
Background and objectives: The laryngeal mask is the method of choice for airway management in children during minor surgical procedures. There is a paucity of data regarding optimal management of mechanical ventilation in these patients. The Supreme™ airway laryngeal mask offers the option to insert a gastric tube to empty the stomach contents of air and/or gastric juice. The aim of this investigation was to evaluate the impact of positive end-expiratory positive pressure (PEEP) levels on ventilation parameters and gastric air insufflation during general anesthesia in children using pressure-controlled ventilation with laryngeal mask. Materials and Methods: An observational trial was carried out in 67 children aged between 1 and 11 years. PEEP levels of 0, 3 and 5 mbar were tested for 5 min in each patient during surgery and compared with ventilation parameters (dynamic compliance (mL/cmH2O), etCO2 (mmHg), peak pressure (mbar), tidal volume (mL), respiratory rate (per minute), FiO2 and gastric air (mL)) were measured at each PEEP. Air was aspirated from the stomach at the start of the sequence of measurements and at the end. Results: Significant differences were observed for the ventilation parameters: dynamic compliance (PEEP 5 vs. PEEP 3: p < 0.0001, PEEP 5 vs. PEEP 0: p < 0.0001, PEEP 3 vs. PEEP 0: p < 0.0001), peak pressure (PEEP 5 vs. PEEP 3: p < 0.0001, PEEP 5 vs. PEEP 0: p < 0.0001, PEEP 3 vs. PEEP 0: p < 0.0001) and tidal volume (PEEP 5 vs. PEEP 3: p = 0.0048, PEEP 5 vs. PEEP 0: p < 0.0001, PEEP 3 vs. PEEP 0: p < 0.0001). All parameters increased significantly with higher PEEP, with the exception of etCO2 (significant decrease) and respiratory rate (no significant difference). We also showed different values for air quantity in the comparisons between the different PEEP levels (PEEP 5: 2.8 ± 3.9 mL, PEEP 3: 1.8 ± 3.0 mL; PEEP 0: 1.6 ± 2.3 mL) with significant differences between PEEP 5 and PEEP 3 (p = 0.0269) and PEEP 5 and PEEP 0 (p = 0.0209). Conclusions: Our data suggest that ventilation with a PEEP of 5 mbar might be more lung protective in children using the Supreme™ airway laryngeal mask, although gastric air insufflation increased with higher PEEP. We recommend the use of a laryngeal mask with the option of inserting a gastric tube to evacuate potential gastric air.
Collapse
|
3
|
Dadure C, Sabourdin N, Veyckemans F, Babre F, Bourdaud N, Dahmani S, Queiroz MD, Devys JM, Dubois MC, Kern D, Laffargue A, Laffon M, Lejus-Bourdeau C, Nouette-Gaulain K, Orliaguet G, Gayat E, Velly L, Salvi N, Sola C. Management of the child's airway under anaesthesia: The French guidelines. Anaesth Crit Care Pain Med 2019; 38:681-693. [PMID: 30807876 DOI: 10.1016/j.accpm.2019.02.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To provide French guidelines about "Airway management during paediatric anaesthesia". DESIGN A consensus committee of 17 experts from the French Society of Anaesthesia and Intensive Care Medicine (Société Française d'Anesthésie-Réanimation, SFAR) and the Association of French speaking paediatric anaesthesiologists and intensivists (Association Des Anesthésistes Réanimateurs Pédiatriques d'Expression Francophone, ADARPEF) was convened. The entire process was conducted independently of any industry funding. The authors followed the principles of the Grading of Recommendations Assessment, Development and Evaluation (GRADE®) system to assess the quality of evidence. The potential drawbacks of making strong recommendations in the presence of low-quality evidence were emphasised. Few recommendations were not graded. METHODS The panel focused on 7 questions: 1) Supraglottic Airway devices 2) Cuffed endotracheal tubes 3) Videolaryngoscopes 4) Neuromuscular blocking agents 5) Rapid sequence induction 6) Airway device removal 7) Airway management in the child with recent or ongoing upper respiratory tract infection. Population, intervention, comparison, and outcomes (PICO) questions were reviewed and updated as needed, and evidence profiles were generated. The analysis of the literature and the redaction of the recommendations were then conducted according to the GRADE® methodology. RESULTS The SFAR Guideline panel provides 17 statements on "airway management during paediatric anaesthesia". After two rounds of discussion and various amendments, a strong agreement was reached for 100% of the recommendations. Of these recommendations, 6 have a high level of evidence (Grade 1 ± ), 6 have a low level of evidence (Grade 2 ± ) and 5 are experts' opinions. No recommendation could be provided for 3 questions. CONCLUSIONS Substantial agreement exists among experts regarding many strong recommendations for paediatric airway management.
Collapse
Affiliation(s)
- Christophe Dadure
- Département d'anesthesiologie réanimation femme-mère-enfant, CHU de Lapeyronie, institut de génomique fonctionnelle, UMR 5203 CNRS - U 1191 Inserm, université de Montpellier, 34285 Montpellier, France.
| | - Nada Sabourdin
- Département d'anesthésiologie-réanimation hôpital Armand Trousseau, AP-HP, 26, avenue du Dr Arnold-Netter, 75012 Paris, France
| | - Francis Veyckemans
- Department of paediatric anaesthesia, Jeanne de Flandre hospital, university hospitals of Lille, 59037 Lille, France
| | - Florence Babre
- Department of anaesthesia, Bergonié institute, 33000 Bordeaux, France
| | - Nathalie Bourdaud
- Département d'Anesthésiologie Réanimation Pédiatrique, Hôpital Femme Mère Enfant, 69677 Bron, France
| | - Souhayl Dahmani
- Department of anaesthesia and intensive care. Robert-Debré university hospital, assistance publique Hôpitaux de Paris, Paris Diderot University, Paris Sorbonne Cité, Paris, Paris Diderot University (Paris VII), PRES Paris Sorbonne Cité, Paris, DHU PROTECT, Inserm U1141, Robert-Debré University Hospital, 75019 Paris, France
| | - Mathilde De Queiroz
- Département d'Anesthésiologie Réanimation Pédiatrique, Hôpital Femme Mère Enfant, 69677 Bron, France
| | - Jean-Michel Devys
- Service d'anesthésie-réanimation, fondation ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France
| | - Marie-Claude Dubois
- Service d'anesthésie-réanimation, fondation ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France
| | - Delphine Kern
- Departments of anaesthesia and intensive care, university hospital of Toulouse, place du Dr Baylac, TSA 40031, 31059 Toulouse cedex 9, France
| | - Anne Laffargue
- Department of paediatric anaesthesia, Jeanne de Flandre hospital, university hospitals of Lille, 59037 Lille, France
| | - Marc Laffon
- Department of anesthesia and intensive care, university hospital and medical university François-Rabelais, Tours, France
| | - Corinne Lejus-Bourdeau
- Service d'anesthesie réanimation chirurgicale, Hôtel Dieu, Hôpital Mère Enfant, CHU de Nantes, 44093 Nantes cedex, France
| | - Karine Nouette-Gaulain
- Service d'anesthésie réanimation Pellegrin, hôpital Pellegrin, CHU de Bordeaux, place Amélie Raba Léon, 33000 Bordeaux, France; Université Bordeaux, Inserm U12-11, laboratoire de maladies rares: génétique et métabolisme (MRGM), 176, rue Léo-Saignat, 33000 Bordeaux, France
| | - Gilles Orliaguet
- Department of anaesthesia and intensive care, assistance publique Hôpitaux de Paris, Necker-Enfants Malades hospital, EA08 pharmacologie et évaluation des thérapeutiques chez l'enfant et la femme enceinte, Paris Descartes University (Paris V), PRES Paris Sorbonne Cité, 75743 Paris, France
| | - Etienne Gayat
- Department of anesthesiology and Intensive care, Saint Louis, Lariboisière university hospital, université Paris Diderot, BioCANVAS, UMR-S 942, Inserm, 75010 Paris, France
| | - Lionel Velly
- Service d'anesthesie réanimation, CHU de Timone adultes, 264, rue St Pierre, 13005 MeCA, institut de neurosciences de la Timone, UMR 7289, Aix Marseille université, Marseille, France
| | - Nadège Salvi
- Department of anaesthesia and intensive care, assistance publique Hôpitaux de Paris, Necker-Enfants Malades Hospital, 75743 Paris, France
| | - Chrystelle Sola
- Département d'anesthesiologie réanimation femme-mère-enfant, CHU de Lapeyronie, institut de génomique fonctionnelle, UMR 5203 CNRS - U 1191 Inserm, université de Montpellier, 34285 Montpellier, France
| |
Collapse
|
4
|
Chaw SH, Shariffuddin II, Foo LL, Lee PK, Paran RM, Cheang PC, Chan L. Comparison of clinical performance of size 1.5 Supreme™ LMA and Proseal™ LMA among Asian children: a randomized controlled trial. J Clin Monit Comput 2018; 32:1093-1099. [DOI: 10.1007/s10877-018-0109-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Accepted: 01/31/2018] [Indexed: 10/18/2022]
|
5
|
Actualización en dispositivos supraglóticos para la vía aérea pediátrica. COLOMBIAN JOURNAL OF ANESTHESIOLOGY 2017. [DOI: 10.1016/j.rca.2017.07.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
6
|
Lee YC, Yoon KS, Park SY, Choi SR, Chung CJ. A comparison of i-gel™ and Laryngeal Mask Airway Supreme™ during general anesthesia in infants. Korean J Anesthesiol 2017; 71:37-42. [PMID: 29441173 PMCID: PMC5809706 DOI: 10.4097/kjae.2018.71.1.37] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 06/05/2017] [Accepted: 06/20/2017] [Indexed: 12/03/2022] Open
Abstract
Background The i-gel™ (i-gel) and Laryngeal Mask Airway Supreme™ (LMA Supreme) have been safely used in children. We compared the airway performance of the i-gel and LMA Supreme in infants undergoing general anesthesia. Methods Sixty infants with American Society of Anesthesiologists physical status I or II were randomly assigned to place either the i-gel or the LMA Supreme. The size 1 or 1.5 of each airway was selected by the weight of infants. The primary outcome variable was oropharyngeal leak pressure (OLP). We also assessed insertion success rate, insertion time, fiberoptic view of the larynx, airway quality, airway manipulations, and perioperative complications. Results Demographic data did not differ between the two groups. Insertion success rate was similar in both groups. OLP for the i-gel (26.0 ± 3.8 cmH2O) was higher than for the LMA Supreme (23.7 ± 3.2 cmH2O) (P = 0.016). Insertion time for the i-gel (16.4 ± 2.8 s) was shorter than for the LMA Supreme (18.5 ± 2.7 s) (P = 0.002). There were no differences in fiberoptic view of the larynx, airway quality, airway manipulations, and complications between the two groups. Conclusions This study demonstrated that the i-gel and LMA Supreme provided a similar performance of airway in infants. Compared with the LMA Supreme, the i-gel provided shorter insertion time and higher OLP in infants.
Collapse
Affiliation(s)
- Yoon Chan Lee
- Department of Anesthesiology and Pain Medicine, Dong-A University Hospital, Busan, Korea
| | - Kyoung Seop Yoon
- Department of Anesthesiology and Pain Medicine, Dong-A University Hospital, Busan, Korea
| | - Sang Yoong Park
- Department of Anesthesiology and Pain Medicine, Dong-A University Hospital, Busan, Korea
| | - So Ron Choi
- Department of Anesthesiology and Pain Medicine, Dong-A University Hospital, Busan, Korea
| | - Chan Jong Chung
- Department of Anesthesiology and Pain Medicine, Dong-A University Hospital, Busan, Korea
| |
Collapse
|
7
|
Affiliation(s)
- Jeong Rim Lee
- Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
8
|
Mihara T, Asakura A, Owada G, Yokoi A, Ka K, Goto T. A network meta-analysis of the clinical properties of various types of supraglottic airway device in children. Anaesthesia 2017; 72:1251-1264. [PMID: 28737223 DOI: 10.1111/anae.13970] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/19/2017] [Indexed: 01/02/2023]
Abstract
We conducted both conventional pairwise and Bayesian network meta-analyses to compare the clinical properties of supraglottic airway devices in children. We searched six databases for randomised clinical trials. Our primary end-points were oropharyngeal leak pressure, risk of insertion failure at first attempt, and blood staining risk. The risk of device failure, defined as the abandonment of the supraglottic airway device and replacement with a tracheal tube or another device, was also analysed. Sixty-five randomised clinical trials with 5823 participants were identified, involving 16 types of supraglottic airway device. Network meta-analysis showed that the i-gel™, Cobra perilaryngeal airway™ and Proseal laryngeal mask airway (LMA® -Proseal) showed statistically significant differences in oropharyngeal leak pressure compared with the LMA® -Classic, with mean differences (95% credible interval, CrI) of 3.6 (1.9-5.8), 4.6 (1.7-7.6) and 3.4 (2.0-4.8) cmH2 O, respectively. The i-gel was the only device that significantly reduced the risk of blood staining of the device compared with the LMA-Classic, with an odds ratio (95%CrI) of 0.46 (0.22-0.90). The risk (95%CI) of device failure with the LMA-Classic, LMA® -Unique and LMA-Proseal was 0.36% (0.14-0.92%), 0.49% (0.13-1.8%) and 0.50% (0.23-1.1%), respectively, whereas the risk (95%CI) of the i-gel and PRO-Breathe was higher, at 3.4% (2.5-4.7%) and 6.0% (2.8-12.5%), respectively. The risk, expressed as odds ratio (95%CrI), of insertion failure at first attempt, was higher in patients weighing < 10 kg at 5.1 (1.6-20.1). We conclude that the LMA-Proseal may be the best supraglottic airway device for children as it has a high oropharyngeal leak pressure and a low risk of insertion. Although the i-gel has a high oropharyngeal leak pressure and low risk of blood staining of the device, the risk of device failure should be evaluated before its routine use can be recommended.
Collapse
Affiliation(s)
- T Mihara
- Department of Anaesthesiology, Kanagawa Children's Medical Centre, Yokohama, Japan.,Department of Anaesthesiology and Critical Care Medicine, Graduate School of Medicine, Yokohama City University, Yokohama, Japan
| | - A Asakura
- Department of Anaesthesiology and Critical Care Medicine, Graduate School of Medicine, Yokohama City University, Yokohama, Japan
| | - G Owada
- Department of Anaesthesiology and Critical Care Medicine, Graduate School of Medicine, Yokohama City University, Yokohama, Japan
| | - A Yokoi
- Department of Anaesthesiology, Kanagawa Children's Medical Centre, Yokohama, Japan
| | - K Ka
- Department of Anaesthesiology, Kanagawa Children's Medical Centre, Yokohama, Japan
| | - T Goto
- Department of Anaesthesiology and Critical Care Medicine, Graduate School of Medicine, Yokohama City University, Yokohama, Japan
| |
Collapse
|
9
|
Chen KZ, Liu TJ, Li WX, Shen X. Optimal flexible laryngeal mask airway size in children weighing 10 to 20 kg. Anaesth Intensive Care 2017; 44:593-8. [PMID: 27608342 DOI: 10.1177/0310057x1604400506] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This prospective, randomised study was conducted to assess the effect of flexible laryngeal mask airway (FLMA) size on oropharyngeal leak pressure (OLP) in children at the recommended intracuff pressure. A total of 120 children undergoing elective ophthalmic surgery were randomly assigned to the size 2 FLMA group or size 2.5 FLMA group. The primary measurement was OLP at an intracuff pressure of 40 cmH2O. Secondary outcomes included the incidence of OLP <10 cmH2O, insufficient ventilation, gastric insufflation, insertion time, successful first-attempt insertion rate, fibreoptic view grade and pharyngolaryngeal adverse events. The median OLP was comparable for the size 2 and size 2.5 FLMA (18 cmH2O versus 18 cmH2O, P=0.38). However, the size 2 FLMA group had a higher incidence of OLP <10 cmH2O and insufficient ventilation (13.3% versus 0, P=0.006). In subgroup analyses based on weight, the size 2.5 FLMA had a lower occurrence of OLP <10 cmH2O and insufficient ventilation (27% versus 0, P=0.0046) in children 16-20 kg. We conclude that at a 40 cmH2O intracuff pressure, the OLP with the size 2 and size 2.5 FLMA was similar in children weighing 10-15.9 kg. However, in children weighing 16-20 kg, size 2 devices had a higher incidence of low OLP and insufficient ventilation, so a 2.5 FLMA may be preferable in this subgroup.
Collapse
Affiliation(s)
- K Z Chen
- Anesthesiologist, Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
| | - T J Liu
- Anesthesiologist, Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
| | - W X Li
- Anesthesiologist, Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
| | - X Shen
- Anesthesiologist, Department of Anesthesiology, Shanghai Eye, Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
| |
Collapse
|
10
|
Selected abstracts presented at the World Airway Management Meeting, 12–14 November 2015, Dublin, Ireland. Br J Anaesth 2016. [DOI: 10.1093/bja/aew183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
11
|
Huang AS, Hajduk J, Jagannathan N. Advances in supraglottic airway devices for the management of difficult airways in children. Expert Rev Med Devices 2016; 13:157-69. [PMID: 26700886 DOI: 10.1586/17434440.2016.1136210] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
There are innumerable tools and devices available to facilitate airway management and life-saving gas exchange of the patient's lungs. Over the years, various designs and generations of supraglottic airway devices have proven to be effective in accomplishing this function. Their application has grown beyond the original purpose of controlling the normal pediatric airway without tracheal intubation, and has been incorporated in the difficult airway management algorithms of anesthesia societies around the world based on clear evidence of efficacy. Older supraglottic airway devices since the 1980's have been validated in multiple clinical trials to be safe and effective in the pediatric population, however there is also sufficient evidence that the newer designs have features that help overcome some limitations. These newer designs and features are effective in managing both the normal and difficult pediatric airway, and will be discussed in this comprehensive review.
Collapse
Affiliation(s)
- Andrea S Huang
- a Department of Pediatric Anesthesia , Ann and Robert H. Lurie Children's Hospital of Chicago , Chicago , IL , USA.,b Department of Anesthesiology , Northwestern University Feinberg School of Medicine , Chicago , IL , USA
| | - John Hajduk
- a Department of Pediatric Anesthesia , Ann and Robert H. Lurie Children's Hospital of Chicago , Chicago , IL , USA
| | - Narasimhan Jagannathan
- a Department of Pediatric Anesthesia , Ann and Robert H. Lurie Children's Hospital of Chicago , Chicago , IL , USA.,b Department of Anesthesiology , Northwestern University Feinberg School of Medicine , Chicago , IL , USA
| |
Collapse
|
12
|
Abstract
Almost all supraglottic airways (SGAs) are now available in pediatric sizes. The availability of these smaller sizes, especially in the last five years has brought a marked change in the whole approach to airway management in children. SGAs are now used for laparoscopic surgeries, head and neck surgeries, remote anesthesia; and for ventilation during resuscitation. A large number of reports have described the use of SGAs in difficult airway situations, either as a primary or a rescue airway. Despite this expanded usage, there remains little evidence to support its usage in prolonged surgeries and in the intensive care unit. This article presents an overview of the current options available, suitability of one over the other and reviews the published data relating to each device. In this review, the author also addresses some of the general concerns regarding the use of SGAs and explores newer roles of their use in children.
Collapse
Affiliation(s)
- Rakhee Goyal
- Department of Anesthesia and Critical Care, Armed Forces Medical College, Pune, Maharashtra, India
| |
Collapse
|
13
|
Jagannathan N, Hajduk J, Sohn L, Huang A, Sawardekar A, Gebhardt ER, Johnson K, De Oliveira GS. A randomised comparison of the Ambu®AuraGain™and the LMA®supreme in infants and children. Anaesthesia 2015; 71:205-12. [DOI: 10.1111/anae.13330] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/20/2015] [Indexed: 11/30/2022]
Affiliation(s)
- N. Jagannathan
- Department of Anesthesia; Ann and Robert H. Lurie Children's Hospital of Chicago; Chicago Illinois USA
| | - J. Hajduk
- Department of Anesthesia; Ann and Robert H. Lurie Children's Hospital of Chicago; Chicago Illinois USA
| | - L. Sohn
- Department of Anesthesia; Ann and Robert H. Lurie Children's Hospital of Chicago; Chicago Illinois USA
| | - A. Huang
- Department of Anesthesia; Ann and Robert H. Lurie Children's Hospital of Chicago; Chicago Illinois USA
| | - A. Sawardekar
- Department of Anesthesia; Ann and Robert H. Lurie Children's Hospital of Chicago; Chicago Illinois USA
| | - E. R. Gebhardt
- Department of Anesthesia; Ann and Robert H. Lurie Children's Hospital of Chicago; Chicago Illinois USA
| | - K. Johnson
- Department of Anesthesia; Ann and Robert H. Lurie Children's Hospital of Chicago; Chicago Illinois USA
| | - G. S. De Oliveira
- Department of Anesthesia; Feinberg School of Medicine; Northwestern University; Chicago Illinois USA
| |
Collapse
|
14
|
Huang A, Jagannathan N. The Role of Supraglottic Airways in Pediatric Emergency Medicine. CLINICAL PEDIATRIC EMERGENCY MEDICINE 2015. [DOI: 10.1016/j.cpem.2015.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
15
|
|
16
|
Kim MS, Lee JH, Han SW, Im YJ, Kang HJ, Lee JR. A randomized comparison of the i-gel with the self-pressurized air-Q intubating laryngeal airway in children. Paediatr Anaesth 2015; 25:405-12. [PMID: 25559870 DOI: 10.1111/pan.12609] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/05/2014] [Indexed: 12/14/2022]
Abstract
BACKGROUND Supraglottic airway devices with noninflatable cuff have advantages in omitting the cuff pressure monitoring and reducing potential pharyngolaryngeal complications. Typical devices without cuff inflation available in children are the i-gel and the self-pressurized air-Q intubating laryngeal airway (air-Q SP). To date, there is no comparative study between these devices in pediatric patients. AIM The purpose of this randomized study was to compare the i-gel(™) and the self-pressurized air-Q(™) intubating laryngeal airway (air-Q SP) in children undergoing general anesthesia. METHODS Eighty children, 1-108 months of age, 7-30 kg of weight, and scheduled for elective surgery in which supraglottic airway devices would be suitable for airway management, were randomly assigned to either the i-gel or the air-Q SP. Oropharyngeal leak pressure and fiberoptic view were assessed three times as follows: after insertion and fixation of the device, 10 min after initial assessment, and after completion of surgery. We also assessed insertion parameters and complications. RESULTS Insertion of the i-gel was regarded as significantly easier compared to the air-Q SP (P = 0.04). Compared to the air-Q SP group, the i-gel group had significantly higher oropharyngeal leak pressures at all measurement points and significantly lower frequencies of gastric insufflation at 10 min after initial assessment and completion of surgery. The air-Q SP group had better fiberoptic views than the i-gel group at all measurement points. CONCLUSION Our results showed that the i-gel had easier insertion and better sealing function, and the air-Q SP provided improved fiberoptic views in children requiring general anesthesia.
Collapse
Affiliation(s)
- Min-Soo Kim
- Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | | | | | | | | | | |
Collapse
|
17
|
Choi KW, Lee JR, Oh JT, Kim DW, Kim MS. The randomized crossover comparison of airway sealing with the laryngeal mask airway Supreme(™) at three different intracuff pressures in children. Paediatr Anaesth 2014; 24:1080-7. [PMID: 25059727 DOI: 10.1111/pan.12494] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/26/2014] [Indexed: 11/27/2022]
Abstract
BACKGROUND An intracuff pressure of 80 cm H2 O in the adult-sized laryngeal mask airway Supreme has been recommended to obtain a higher oropharyngeal leak pressure (OLP). However, the intracuff pressure for the higher OLP in the pediatric laryngeal mask airway Supreme could be different from that in the adult-sized laryngeal mask airway Supreme. Thus, we measured and compared OLP at three intracuff pressures of 40, 60, and 80 cm H2 O in the pediatric laryngeal mask airway Supreme. METHODS This study was designed as a randomized crossover study and enrolled 36 children, aged 0-108 months and 5-30 kg in weight. After insertion of the laryngeal mask airway Supreme, oropharyngeal leak pressure (OLP) was measured at intracuff pressures of 40, 60, and 80 cm H2 O according to one of six sequences produced on the basis of 3 × 6 Williams crossover design. During the intraoperative period, the laryngeal mask airway Supreme was maintained using the last intracuff pressure of the allocated sequence. The intraoperative and postoperative complications were compared among three maintenance intracuff pressures. RESULTS OLP at the intracuff pressure of 60 cm H2 O was significantly higher than that of 40 cm H2 O (17.9 ± 3.9 vs 16.9 ± 4.2 cm H2 O, P = 0.004) and was comparable with that of 80 cm H2 O (17.9 ± 3.9 vs 17.8 ± 4.6 cm H2 O, P = 0.938). There were no significant differences of intraoperative and postoperative complications among the three maintenance intracuff pressures. CONCLUSION Our results suggest that the use of an intracuff pressure of 60 cm H2 O in pediatric laryngeal mask airway Supreme provides a higher OLP compared with 40 cm H2 O.
Collapse
Affiliation(s)
- Kwan-Woong Choi
- Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | | | | | | | | |
Collapse
|