1
|
Kamal G, Agarwal D, Agarwal S, Gupta A, Gupta A, Kalra B, Gupta N. A prospective randomized comparative trial of pediatric C-MAC D-blade video laryngoscope with McCoy direct laryngoscope for intubation in children posted for elective surgical procedures under general anesthesia. Paediatr Anaesth 2024; 34:750-757. [PMID: 38682461 DOI: 10.1111/pan.14911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 04/16/2024] [Accepted: 04/17/2024] [Indexed: 05/01/2024]
Abstract
BACKGROUND Pediatric airway management requires careful clinical evaluation and experienced execution due to anatomical, physiological, and developmental considerations. Video laryngoscopy in pediatric airways is a developing area of research, with recent data suggesting that video laryngoscopes are better than standard Macintosh blades. Specifically, there is a paucity of literature on the advantages of the C-MAC D-blade compared to the McCoy direct laryngoscope. METHODS After Ethics Committee approval, 70 American Society of Anesthesiologists physical status 1 and 2 children aged 4-12 years scheduled for elective surgery under general anesthesia were recruited. Patients were randomly allocated to intubation using a C-MAC video laryngoscope size 2 D-blade (Group 1) and a McCoy laryngoscope size 2 blade (Group 2). The Intubation Difficulty Scale (IDS) for ease of intubation was the primary outcome, while Cormack-Lehane grades, duration of laryngoscopy and intubation, hemodynamic responses, and incidence of any airway complications were secondary outcomes. RESULTS Both groups were comparable in terms of patient characteristics. The median (IQR) Intubation Difficulty Scale (IDS) score was better but was statistically nonsignificant with C-MAC (0 [0-0] vs. 0 [0-2], p = .055). The glottic views were superior (CL grade I in 32/35 vs. 23/35, p = .002), and the time to best glottic view (6 s [5-7] vs. 8.0 s [6-10], p = .006) was lesser in the C-MAC D-blade group while the total duration of intubation was comparable (20 s [16-22] vs. 18 s [15-22], p = .374). All the patients could be successfully intubated on the first attempt. None of the patients had any complications. CONCLUSION The C-MAC video laryngoscope size 2 D-blade provided faster and better glottic visualization but similar intubation difficulty compared to McCoy size 2 laryngoscope in children. The shorter time to achieve glottic view demonstrated with the C-MAC failed to translate into a shorter total duration of intubation when compared to the McCoy laryngoscope attributable to a pronounced curvature of the D-blade.
Collapse
Affiliation(s)
- Geeta Kamal
- Chacha Nehru Bal Chikitsalya, New Delhi, India
| | | | | | - Anju Gupta
- All India Institute of Medical Sciences, New Delhi, India
| | - Aikta Gupta
- Chacha Nehru Bal Chikitsalya, New Delhi, India
| | | | | |
Collapse
|
2
|
Nedunchezhian V, Nedunchezhian I, Van Zundert A. Clinically Preferred Videolaryngoscopes in Airway Management: An Updated Systematic Review. Healthcare (Basel) 2023; 11:2383. [PMID: 37685417 PMCID: PMC10487223 DOI: 10.3390/healthcare11172383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 08/11/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023] Open
Abstract
Videolaryngoscopes (VLs) have emerged as a safety net offering several advantages over direct laryngoscopy (DL). The aim of this study is to expand on our previous study conducted in 2016, to deduce which VL is most preferred by clinicians and to highlight any changes that may have occurred over the past 7 years. An extensive systematic literature review was performed on Medline, Embase, Web of Science, and Cochrane Central Database of Controlled Studies for articles published between September 2016 and January 2023. This review highlighted similar results to our study in 2016, with the CMAC being the most preferred for non-channelled laryngoscopes, closely followed by the GlideScope. For channelled videolaryngoscopes, the Pentax AWS was the most clinically preferred. This review also highlighted that there are minimal studies that compare the most-used VLs, and thus we suggest that future studies directly compare the most-used and -preferred VLs as well as the specific nature of blades to attain more useful results.
Collapse
Affiliation(s)
- Vikram Nedunchezhian
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women’s Hospital, The University of Queensland, Brisbane, QLD 4029, Australia;
| | - Ishvar Nedunchezhian
- School of Medicine and Dentistry, Griffith University, Gold Coast, QLD 4215, Australia;
| | - André Van Zundert
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women’s Hospital, The University of Queensland, Brisbane, QLD 4029, Australia;
| |
Collapse
|
3
|
Shaylor R, Weiniger CF, Rachman E, Sela Y, Kohn A, Lahat S, Rimon A, Capua T. A Prospective Observational Crossover Study Comparing Intubation by Pediatric Residents Using Video Laryngoscopy and Direct Laryngoscopy on a Pierre Robin Simulation Manikin. Pediatr Emerg Care 2023; 39:159-161. [PMID: 36791027 DOI: 10.1097/pec.0000000000002923] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
INTRODUCTION Video laryngoscopy (VL) has been proposed to increase the likelihood of successful intubation in patients with predicted difficult airways such as those with Pierre Robin sequence (PRS). Prior studies have focused on the performance of anesthesiologists, who are generally considered airway experts. Our primary aim was to investigate the success rate of intubation using VL compared with direct laryngoscopy (DL) when attempted by pediatric residents on a PRS model. METHODS Participants were administered a 5-minute refresher video on 2 VL techniques (CMAC, conventional geometry VL, and McGrath, unconventional geometry VL) and DL. The participants were asked to intubate the AirSim PRS infant manikin. The order of VL and DL use was randomly selected. All intubations were video recorded, and the recordings were analyzed by 3 anesthesiologists blinded to the participant's identity and previous experience. RESULTS Seventeen of 23 residents succeeded in intubating the PRS model using DL. Only 9 residents succeeded in intubating the PRS model using VL (conventional or unconventional geometry). Intubation success rate was higher when comparing DL with VL ( P = 0.04) and similar when comparing VL devices ( P = 0.69). DISCUSSION Contrary to expectation, the intubation success rate was lower using VL than with DL among pediatric residents. This should be considered when designing residency training and in real-life resuscitation.
Collapse
Affiliation(s)
- Ruth Shaylor
- From the Department of Anesthesia, Tel Aviv Sourasky Medical Center
| | | | - Evgeny Rachman
- From the Department of Anesthesia, Tel Aviv Sourasky Medical Center
| | - Yarden Sela
- Medical Technology and Simulation Center, Tel Aviv Sourasky Medical Center, Affiliated to Ministry of Health
| | - Aryeh Kohn
- Medical Technology and Simulation Center, Tel Aviv Sourasky Medical Center, Affiliated to Ministry of Health
| | | | - Ayelet Rimon
- Pediatric Emergency Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | | |
Collapse
|
4
|
Moritz A, Holzhauser L, Fuchte T, Kremer S, Schmidt J, Irouschek A. Comparison of Glidescope Core, C-MAC Miller and conventional Miller laryngoscope for difficult airway management by anesthetists with limited and extensive experience in a simulated Pierre Robin sequence: A randomized crossover manikin study. PLoS One 2021; 16:e0250369. [PMID: 33886650 PMCID: PMC8062059 DOI: 10.1371/journal.pone.0250369] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 04/04/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Video laryngoscopy is an effective tool in the management of difficult pediatric airway. However, evidence to guide the choice of the most appropriate video laryngoscope (VL) for airway management in pediatric patients with Pierre Robin syndrome (PRS) is insufficient. Therefore, the aim of this study was to compare the efficacy of the Glidescope® Core™ with a hyperangulated blade, the C-MAC® with a nonangulated Miller blade (C-MAC® Miller) and a conventional Miller laryngoscope when used by anesthetists with limited and extensive experience in simulated Pierre Robin sequence. METHODS Forty-three anesthetists with limited experience and forty-three anesthetists with extensive experience participated in our randomized crossover manikin trial. Each performed endotracheal intubation with the Glidescope® Core™ with a hyperangulated blade, the C-MAC® with a Miller blade and the conventional Miller laryngoscope. "Time to intubate" was the primary endpoint. Secondary endpoints were "time to vocal cords", "time to ventilate", overall success rate, number of intubation attempts and optimization maneuvers, Cormack-Lehane score, severity of dental trauma and subjective impressions. RESULTS Both hyperangulated and nonangulated VLs provided superior intubation conditions. The Glidescope® Core™ enabled the best glottic view, caused the least dental trauma and significantly decreased the "time to vocal cords". However, the failure rate of intubation was 14% with the Glidescope® Core™, 4.7% with the Miller laryngoscope and only 2.3% with the C-MAC® Miller when used by anesthetists with extensive previous experience. In addition, the "time to intubate", the "time to ventilate" and the number of optimization maneuvers were significantly increased using the Glidescope® Core™. In the hands of anesthetists with limited previous experience, the failure rate was 11.6% with the Glidescope® Core™ and 7% with the Miller laryngoscope. Using the C-MAC® Miller, the overall success rate increased to 100%. No differences in the "time to intubate" or "time to ventilate" were observed. CONCLUSIONS The nonangulated C-MAC® Miller facilitated correct placement of the endotracheal tube and showed the highest overall success rate. Our results therefore suggest that the C-MAC® Miller could be beneficial and may contribute to increased safety in the airway management of infants with PRS when used by anesthetists with limited and extensive experience.
Collapse
Affiliation(s)
- Andreas Moritz
- Department of Anesthesiology, Faculty of Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- * E-mail:
| | - Luise Holzhauser
- Department of Anesthesiology, Faculty of Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Tobias Fuchte
- Department of Anesthesiology, Faculty of Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Sven Kremer
- Department of Anesthesiology, Faculty of Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Joachim Schmidt
- Department of Anesthesiology, Faculty of Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Andrea Irouschek
- Department of Anesthesiology, Faculty of Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
5
|
Comparison of the MultiViewScope Stylet Scope and the direct laryngoscope with the Miller blade for the intubation in normal and difficult pediatric airways: A randomized, crossover, manikin study. PLoS One 2020; 15:e0237593. [PMID: 32790734 PMCID: PMC7425958 DOI: 10.1371/journal.pone.0237593] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 07/30/2020] [Indexed: 12/26/2022] Open
Abstract
Background Managing difficult pediatric airway is challenging. The MultiViewScope (MVS) Stylet Scope is reported to be useful in difficult pediatric airway. In this randomized crossover study, we compared the effectiveness of the MVS Stylet Scope to a standard direct laryngoscope with Miller #1 blade in simulated normal and difficult airways. Methods Fifteen expert anesthesiologists and Fifteen anesthesiology residents participated in the study. Participants were asked to perform intubation with the Airsim Baby manikin first, and then with the Airsim Pierre Robin manikin. Participants in each group used the intubation devices in a randomized order. The primary outcome was the time of successful intubation. The secondary outcomes were the force exerted on the incisors during intubation, Cormack–Lehane scale, the difficulty of intubation. Results There were no differences between MVS Stylet Scope and Direct laryngoscope in the time of successful intubation by the expert anesthesiologists or the anesthesiology residents in a normal or difficult pediatric airway. MVS Stylet Scope significantly improved the force exerted on the incisors during intubation in the expert anesthesiologists or the anesthesiology residents in a normal or difficult pediatric airway. MVS Stylet Scope significantly improved Cormack–Lehane scale, and the difficulty of intubation with difficult pediatric airway situation in both expert anesthesiologists and anesthesiology residents. Conclusions Although less forces on the incisors and improved view of glottis were observed with the MVS Stylet Scope, MVS Stylet Scope did not shorten the time of intubation. The results of this study mean that the MVS Stylet Scope may be a less invasive airway devise than the direct laryngoscope with the Miller blade in the pediatric airway management. For the next step, we need to evaluate the MVS Stylet Scope in the real patients as an observational study.
Collapse
|
6
|
Perez FA, Hottinger DG, Evans KN, Giles M, Otto RK, Hunyady A, Gentry KR. Longer upper airway lengths in Robin Sequence: A case-control study using computed tomography. Paediatr Anaesth 2020; 30:683-690. [PMID: 32277728 DOI: 10.1111/pan.13869] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 02/29/2020] [Accepted: 03/23/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Direct laryngoscopy and intubation are often difficult in children with Robin Sequence. Previous research characterizing anatomic airway differences has focused on parameters influencing airway patency; there is a paucity of data pertaining to intubation trajectories and depth. Such information could impact airway management approaches and decrease the incidence of endotracheal tube malpositioning. AIM The study goal was to examine whether longitudinal airway parameters pertaining to intubation are different in children with Robin Sequence compared with age-matched controls. METHOD This case-control study compared patients with RS <4 years of age who had computed tomography scans of the head and neck to age- and sex-matched controls. Measurements were made of the nasopharynx, oropharynx, hypopharynx, tongue, hyoid, and the front teeth to vocal cord, nares to vocal cord, and nasion-basion distances. Statistical analysis was performed using multiple ANCOVA models with the categorical predictor of Robin Sequence vs control and potential covariates including subject height/length, weight, and age. RESULTS Thirty-three patients with Robin Sequence and 33 control subjects were included. After controlling for subject height/length, mean front teeth to vocal cord distance was 1.2 cm longer (95% CI: 0.9 to 1.6 cm, P < .001) and mean nares to vocal cord distance was 0.8 cm longer (95% CI: 0.4 to 1.2 cm, P < .001) in patients with Robin Sequence than in controls. The tongue was positioned on average 0.5 cm higher (95% CI: 0.3 to 0.8, P < .001) and 0.9 cm more posterior (95% CI: 0.6 to 1.0 cm, P < .001) in cases than in controls. Moreover, in patients with Robin Sequence, the hyoid was positioned on average 0.5 cm more inferiorly (95% CI: 0.2 to 0.8 cm, P < .001) and 0.2 cm more posteriorly (95% CI: 0.1 to 0.4 cm, P < .01) than controls. CONCLUSION In patients with Robin Sequence under 4 years of age, the mean front teeth to vocal cord distance was found to be 1.2 cm longer while the mean nares to vocal cord distance was found to be 0.8 cm longer controlling for subject length. Clinicians should account for these differences when selecting and placing endotracheal tubes, particularly those with a preformed bend.
Collapse
Affiliation(s)
- Francisco A Perez
- Department of Radiology, Seattle Children's Hospital and University of Washington School of Medicine, Seattle, WA, USA
| | | | - Kelly N Evans
- Department of Pediatrics, Division of Craniofacial Medicine, University of Washington School of Medicine, Seattle, WA, USA
| | - Marian Giles
- Department of Anesthesiology and Pain Medicine, University of Washington School of Medicine, Seattle, WA, USA
| | - Randolph K Otto
- Department of Radiology, Seattle Children's Hospital and University of Washington School of Medicine, Seattle, WA, USA
| | - Agnes Hunyady
- Department of Anesthesiology and Pain Medicine, Division of Pediatric Anesthesiology, University of Washington School of Medicine, Seattle, WA, USA
| | - Katherine R Gentry
- Department of Anesthesiology and Pain Medicine, Division of Pediatric Anesthesiology, University of Washington School of Medicine, Seattle, WA, USA
| |
Collapse
|
7
|
Comparison of Macintosh Laryngoscope and GlideScope® for Orotracheal Intubation in Children Older Than One Year. MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL 2020; 53:143-147. [PMID: 32377073 PMCID: PMC7199836 DOI: 10.14744/semb.2019.55631] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Accepted: 05/20/2019] [Indexed: 01/09/2023]
Abstract
Objectives: We aim to investigate intubation conditions, intubation times, and hemodynamic response with the GlideScope video laryngoscope or the Macintosh direct laryngoscope for orotracheal intubation in children older than one year. Methods: Eighty patients aged 1–12 years, scheduled to undergo elective surgery under general anesthesia with endotracheal intubation were included in a prospective, single-blinded, randomized trial. Exclusion criteria were risk of pulmonary aspiration, craniofacial malformation, difficult intubation, emergency surgery, cardiovascular disease, respiratory disease, and hemodynamic instability. After standard anesthesia induction, patients were randomized into two groups. The group G patients (n=40) were intubated with the GlideScope and the group M patients (n=40) were intubated with the Macintosh laryngoscope. Intubation time, number of attempts, Cormack–Lehane score, airway maneuvers, and visual analog score were recorded. Hemodynamic variables were recorded before and after anesthesia induction, at intubation, and 1., 3., and 5. minutes after intubation. Student’s t-test, Mann–Whitney U test, and the χ2 test were used for statistical analysis, with p<0.05 considered significant. Results: The demographic data, operation time and hemodynamic parameters were similar between the two groups. The intubation time was longer in Group G than Group M. The incidence of Cormack–Lehane score 1 was higher in Group G than Group M while Cormack–Lehane score 2 was higher in Group M. Conclusion: We concluded that the GlideScope video laryngoscope provided better glottis visualization, but prolonged intubation time. There was no superiorty on hemodynamic effect with the video laryngoscope.
Collapse
|
8
|
Sinha R, Ray BR, Sharma A, Pandey RK, Punj J, Darlong V, Trikha A. Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study. J Anaesthesiol Clin Pharmacol 2019; 35:509-514. [PMID: 31920236 PMCID: PMC6939578 DOI: 10.4103/joacp.joacp_106_18] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Background and Aims: CMAC video laryngoscope size 2 D-Blade has been recently introduced for management of pediatric difficult airway. Our primary outcome was to compare glottic view, intubation time, and ease of intubation with the size 2 Macintosh versus D-Blade of C-MAC video laryngoscope in simulated cervical injury in children. Material and Methods: This randomized crossover study was conducted in a tertiary care hospital of Northern India. Forty children of 4–14 years of age were enrolled in this study. After induction of anesthesia, video laryngoscopy was performed either with size 2 CMAC Macintosh (group M) or D-Blade (group D) with manual in-line stabilization. After removal of the first blade, second video laryngoscopy was performed with the alternative blade. Endotracheal intubation was done with the second laryngoscopy. Best glottic view, time for best glottic view, and difficulty in blade insertion were recorded during both the video laryngoscopies. During second video laryngoscopy, difficulty of tube insertion and time for intubation were noted. Results: The glottic view grade was significantly better in group D compared with the group M (P = 0.0002). Insertion of D-Blade was more difficult than Macintosh blade (P = 0.0007). There was no statistical difference in terms of time for best glottic view in group M and group D (13.40 ± 4.90 vs 13.62 ± 5.60 s) and endotracheal tube insertion time (24.80 ± 7.90 vs 27.90 ± 10.90 s), respectively. Number of intubation attempts was similar in both the groups. Conclusions: Size 2 D-Blade of C-MAC video laryngoscope provided a better glottic view in children with simulated cervical spine injury as compared with CMAC Macintosh blade. Success of intubation, intubation time, and ease of intubation were comparable with both the blades.
Collapse
Affiliation(s)
- Renu Sinha
- Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India
| | - Bikash Ranjan Ray
- Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India
| | - Ankur Sharma
- Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India
| | - Ravinder Kumar Pandey
- Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India
| | - Jyotsna Punj
- Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India
| | - Vanlalnghaka Darlong
- Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India
| | - Anjan Trikha
- Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
9
|
Kriege M, Pirlich N, Ott T, Wittenmeier E, Dette F. A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study. BMC Anesthesiol 2018; 18:119. [PMID: 30170540 PMCID: PMC6119241 DOI: 10.1186/s12871-018-0580-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Accepted: 08/14/2018] [Indexed: 11/20/2022] Open
Abstract
Background In infants, securing the airway is time-critical because of anatomical and physiological differences related to airway management in children less than 1 year old. The aim of this study was to compare the time to ventilation using two different hyperangulated video laryngoscope blades with the time to ventilation via conventional direct laryngoscopy in a normal airway [NA] and in a simulated difficult airway [DA]. Methods This study was a comparative, bicentric, open-label, randomized controlled evaluation. An infant high-fidelity simulator (SimBaby™; Laerdal® Medical, Stavanger, Norway) was used, and two scenarios were proposed, as follows: NA and DA evoked with tongue edema and cervical collar. After theoretical and practical briefing, each participant compared in the two airway scenarios the novel King Vision™ Pediatric aBlade (KV) (Ambu® A/S, Bad Nauheim, Germany) video laryngoscope and the C-MAC™ D-blade Ped (DB) (Karl Storz® SE & Co. KG, Tuttlingen, Germany) video laryngoscope to conventional laryngoscopy using the Miller Blade (MiB) and the Macintosh Blade (MaB) in a random sequence. Results Eighty physicians (65 AN and 15 PCCM staff) were included. In the NA scenario, the median [IQR] time to successful time to ventilation (TTV) was significantly shorter for the KV at 13 s [12–15 s] than for the MaB at 14.5 s [13–16 s], DB at 14.5 s [13–16] and MiB at 16 s [14–19] (p < 0.001). In DA, the KV also shortened TTV to 14 s [13–16], whereas TTV was 23 s with the MaB [20–26], 19 s with the DB [16–21], and 27 s with the MiB [22–31] (p < 0.001). There were no differences in first-pass intubation success rates (FPAs) between hyperangulated blades and direct laryngoscopes in NA. In DA, the hyperangulated blades enabled 92 (DB) to 100% (KV) FPAs compared with 65 (MiB) to 76% (MaB) for conventional laryngoscopy (p < 0.001). Conclusion Video laryngoscopes with hyperangulated blades were associated with shorter TTV in normal and difficult infant airway situations. The higher FPAs of hyperangulated blades in DA may avoid desaturations and decrease adverse events in pediatric airway management. Electronic supplementary material The online version of this article (10.1186/s12871-018-0580-y) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Marc Kriege
- Department of Anesthesiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, 55131, Mainz, Germany.
| | - Nina Pirlich
- Department of Anesthesiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Thomas Ott
- Department of Anesthesiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Eva Wittenmeier
- Department of Anesthesiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Frank Dette
- Department of Anesthesiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
10
|
Burns in Children. J Burn Care Res 2018; 38:e618-e624. [PMID: 28328667 DOI: 10.1097/bcr.0000000000000536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Children have a great deal to gain from recent and future advances in burn care. A very broad range of realized and potential developments are involved. These will be very briefly reviewed within the context of four areas: 1) early evaluation and care issues, 2) acute surgical and critical care issues, 3) rehabilitation and reconstruction issues, and 4) organizational and outcomes issues.
Collapse
|
11
|
Jagannathan N, von Ungern-Sternberg BS. What can we learn (or not) from in vitro airway studies for clinical applications in children? Paediatr Anaesth 2018; 28:4-5. [PMID: 29226527 DOI: 10.1111/pan.13280] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Narasimhan Jagannathan
- Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA.,Department of Pediatric Anesthesia, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Britta S von Ungern-Sternberg
- Department of Anesthesia and Pain Management, Princess Margaret Hospital for Children, Perth, WA, Australia.,Medical School, Division of Anaesthesiology and Pain Medicine, The University of Western Australia, Perth, WA, Australia
| |
Collapse
|
12
|
C-MAC compared with direct laryngoscopy for intubation in patients with cervical spine immobilization: A manikin trial. Am J Emerg Med 2017; 35:1142-1146. [DOI: 10.1016/j.ajem.2017.03.030] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Accepted: 03/14/2017] [Indexed: 11/23/2022] Open
|
13
|
Truszewski Z, Czyzewski L, Smereka J, Krajewski P, Fudalej M, Madziala M, Szarpak L. Ability of paramedics to perform endotracheal intubation during continuous chest compressions: a randomized cadaver study comparing Pentax AWS and Macintosh laryngoscopes. Am J Emerg Med 2016; 34:1835-9. [PMID: 27369468 DOI: 10.1016/j.ajem.2016.06.054] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 06/12/2016] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVE The aim of the trial was to compare the time parameters for intubation with the use of the Macintosh (MAC) laryngoscope and Pentax AWS-S100 videolaryngoscope (AWS; Pentax Corporation, Tokyo, Japan) with and without chest compression (CC) by paramedics during simulated cardiopulmonary resuscitation in a cadaver model. METHODS This was a randomized crossover cadaver trial. Thirty-five paramedics with no experience in videolaryngoscopy participated in the study. They performed intubation in two emergency scenarios: scenario A, normal airway without CC; scenario B, normal airway with continuous CC. RESULTS The median time to first ventilation with the use of the AWS and the MAC was similar in scenario A: 25 (IQR, 22-27) seconds vs. 24 (IQR, 22.5-26) seconds (P=.072). A statistically significant difference in TTFV between AWS and MAC was noticed in scenario B (P=.011). In scenario A, the first endotracheal intubation (ETI) attempt success rate was achieved in 97.1% with AWS compared with 94.3% with MAC (P=.43). In scenario B, the success rate after the first ETI attempt with the use of the different intubation methods varied and amounted to 88.6% vs. 77.1% for AWS and MAC, respectively (P=.002). CONCLUSIONS The Pentax AWS offered a superior glottic view as compared with the MAC laryngoscope, which was associated with a higher intubation rate and a shorter intubation time during an uninterrupted CC scenario. However, in the scenario without CC, the results for AWS and MAC were comparable.
Collapse
Affiliation(s)
- Zenon Truszewski
- Department of Emergency Medicine, Medical University of Warsaw, Poland
| | - Lukasz Czyzewski
- Department of Nephrologic Nursing, Medical University of Warsaw, Warsaw, Poland
| | - Jacek Smereka
- Department of Emergency Medical Service, Wroclaw Medical University, Wroclaw, Poland
| | - Paweł Krajewski
- Department of Forensic Medicine, Medical University of Warsaw, Warsaw, Poland
| | - Marcin Fudalej
- Department of Forensic Medicine, Medical University of Warsaw, Warsaw, Poland
| | - Marcin Madziala
- Department of Emergency Medicine, Medical University of Warsaw, Poland
| | - Lukasz Szarpak
- Department of Emergency Medicine, Medical University of Warsaw, Poland.
| |
Collapse
|
14
|
Smereka J. Comparison of Airtraq and Miller laryngoscopes for intubation in patients with inline manual neck stabilization. Am J Emerg Med 2016; 34:1721. [PMID: 27318742 DOI: 10.1016/j.ajem.2016.06.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Accepted: 06/03/2016] [Indexed: 11/30/2022] Open
Affiliation(s)
- Jacek Smereka
- Department of Emergency Medical Services, Wroclaw Medical University Wroclaw, Poland.
| |
Collapse
|