1
|
Beringer R, Keith A, Jones E, Murphy T, White P. A prospective comparison of invasive and non-invasive blood pressure in children undergoing cardiac catheterization. Paediatr Anaesth 2023; 33:816-822. [PMID: 37391941 DOI: 10.1111/pan.14723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 06/08/2023] [Accepted: 06/22/2023] [Indexed: 07/02/2023]
Abstract
BACKGROUND Blood pressure measurement is a standard of monitoring during general anesthesia. Invasive measurement is considered the gold standard but is less commonly used than non-invasive. Automated oscillometric blood pressure devices measure the mean arterial pressure (MAP) and use an algorithm to determine the systolic and diastolic pressures. Few devices have been validated in children, particularly during anesthesia. Few studies have assessed the agreement between invasive and non-invasive blood pressure measurements in children. METHODS This was a multi-center prospective observational study of children under 16 years undergoing cardiac catheterization with general anesthesia. Paired invasive and non-invasive blood pressure measurements were recorded for each patient during stable periods of the procedure. Correlation within and between sites was assessed with Pearson's correlation coefficient, and agreement was examined using Bland-Altman methodology to determine bias. Agreement during episodes of hypotension and for age and weight was also determined. Bias greater than 5 mmHg and standard deviation greater than 8 mmHg was considered clinically significant. The primary end point was agreement of MAP measurements. RESULTS A total of 683 paired blood pressure values were collected from 254 children in three pediatric hospitals. Median [IQR] age and weight were 3 [1-7] years and 13.9 [8-23] Kg. The overall bias (SD) for mean arterial pressure values was 7.2 (11.4) mmHg. During hypotension (190 readings), the bias (SD) was 15 (11.0) mmHg. The non-invasive MAP was frequently higher than invasive MAP during infancy, and lower in older children. CONCLUSION Automated oscillometric blood pressure measurement is unreliable in anesthetized children during cardiac catheterization. Invasive pressure measurement should be considered for high-risk cases.
Collapse
Affiliation(s)
| | | | - Elin Jones
- Birmingham Children's Hospital, Birmingham, UK
| | - Tim Murphy
- Bristol Royal Hospital for Children, Bristol, UK
| | - Paul White
- University of the West of England, Bristol, UK
| |
Collapse
|
2
|
Kaplan E, Kadmon G, Nahum E, Alfandary H, Haskin O, Weissbach A. Blood pressure monitoring following kidney transplantation in children: a comparison of invasive and noninvasive measurements using Doppler as a benchmark technique. Pediatr Nephrol 2023; 38:1291-1298. [PMID: 35913567 DOI: 10.1007/s00467-022-05691-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 07/07/2022] [Accepted: 07/07/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND Blood pressure (BP) monitoring following pediatric kidney transplantation is essential for optimizing graft perfusion. Differences between invasive BP and noninvasive BP (NIBP) measurements are sometimes considerable. We aimed to assess agreement between invasive BP and NIBP in pediatric patients after kidney transplantation and compare with measurements obtained by systolic Doppler with manual sphygmomanometer as a reference technique. METHODS A prospective, observational cohort study, of children aged 18 years or younger, admitted immediately following kidney transplantation to the pediatric intensive care unit of a tertiary, university-affiliated medical center, between May 2019 and June 2021. RESULTS Eighty-two paired simultaneous measurements of invasive BP, NIBP, and Doppler BP in 18 patients were compared. Patients were significantly hypertensive, with mean systolic NIBP above the 95th percentile (96 ± 6%). Systolic invasive BP measurements were significantly higher than NIBP (149 ± 20 vs. 136 ± 15 mmHg, p < 0.001). Substantial differences (≥ 20 mmHg) were found in 23% (95% CI 15-34%). Similar disagreement was found between systolic invasive and Doppler BP (150 ± 23 and 137 ± 17 mmHg, respectively, p < 0.001). In contrast, systolic NIBP was in good agreement with Doppler BP (135 ± 17 and 138 ± 18, respectively, p = 0.27). A moderate to strong correlation was found between higher systolic invasive BP and the difference to systolic Doppler BP (Spearman's ρ = 0.63, p < 0.001). CONCLUSIONS In children immediately following kidney transplantation, clinically significant disagreement was found between invasive and noninvasive BP measurements. Invasive BP values were significantly higher than those obtained by Doppler. Better agreement was found between NIBP and Doppler. These issues should be considered when interpreting BP measurements in this sensitive patient population. A higher resolution version of the Graphical abstract is available as Supplementary information.
Collapse
Affiliation(s)
- Eytan Kaplan
- Pediatric Intensive Care Unit, Schneider Children's Medical Center of Israel, 4920235, Petach Tikva, Israel. .,Sackler Faculty of Medicine, Tel Aviv University, 6997801, Tel Aviv, Israel.
| | - Gili Kadmon
- Pediatric Intensive Care Unit, Schneider Children's Medical Center of Israel, 4920235, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, 6997801, Tel Aviv, Israel
| | - Elhanan Nahum
- Pediatric Intensive Care Unit, Schneider Children's Medical Center of Israel, 4920235, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, 6997801, Tel Aviv, Israel
| | - Hadas Alfandary
- Sackler Faculty of Medicine, Tel Aviv University, 6997801, Tel Aviv, Israel.,Institute of Nephrology, Schneider Children's Medical Center of Israel, 4920235, Petach Tikva, Israel
| | - Orly Haskin
- Sackler Faculty of Medicine, Tel Aviv University, 6997801, Tel Aviv, Israel.,Institute of Nephrology, Schneider Children's Medical Center of Israel, 4920235, Petach Tikva, Israel
| | - Avichai Weissbach
- Pediatric Intensive Care Unit, Schneider Children's Medical Center of Israel, 4920235, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, 6997801, Tel Aviv, Israel
| |
Collapse
|
3
|
Abstract
PURPOSE OF REVIEW Neonates have a high risk of perioperative morbidity and mortality. The NEonate and Children audiT of Anaesthesia pRactice IN Europe (NECTARINE) investigated the anesthesia practice, complications and perioperative morbidity and mortality in neonates and infants <60 weeks post menstrual age requiring anesthesia across 165 European hospitals. The goal of this review is to highlight recent publications in the context of the NECTARINE findings and subsequent changes in clinical practice. RECENT FINDINGS A perioperative triad of hypoxia, anemia, and hypotension is associated with an increased overall mortality at 30 days. Hypoxia is frequent at induction and during maintenance of anesthesia and is commonly addressed once oxygen saturation fall below 85%.Blood transfusion practices vary widely variable among anesthesiologists and blood pressure is only a poor surrogate of tissue perfusion. Newer technologies, whereas acknowledging important limitations, may represent the currently best tools available to monitor tissue perfusion. Harmonization of pediatric anesthesia education and training, development of evidence-based practice guidelines, and provision of centralized care appear to be paramount as well as pediatric center referrals and international data collection networks. SUMMARY The NECTARINE provided new insights into European neonatal anesthesia practice and subsequent morbidity and mortality.Maintenance of physiological homeostasis, optimization of oxygen delivery by avoiding the triad of hypotension, hypoxia, and anemia are the main factors to reduce morbidity and mortality. Underlying and preexisting conditions such as prematurity, congenital abnormalities carry high risk of morbidity and mortality and require specialist care in pediatric referral centers.
Collapse
|