1
|
Kriener K, Whiting H, Storr N, Homes R, Lala R, Gabrielyan R, Kuang J, Rubin B, Frails E, Sandstrom H, Futter C, Midwinter M. Applied use of biomechanical measurements from human tissues for the development of medical skills trainers: a scoping review. JBI Evid Synth 2023; 21:2309-2405. [PMID: 37732940 DOI: 10.11124/jbies-22-00363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
OBJECTIVE The objective of this review was to identify quantitative biomechanical measurements of human tissues, the methods for obtaining these measurements, and the primary motivations for conducting biomechanical research. INTRODUCTION Medical skills trainers are a safe and useful tool for clinicians to use when learning or practicing medical procedures. The haptic fidelity of these devices is often poor, which may be because the synthetic materials chosen for these devices do not have the same mechanical properties as human tissues. This review investigates a heterogeneous body of literature to identify which biomechanical properties are available for human tissues, the methods for obtaining these values, and the primary motivations behind conducting biomechanical tests. INCLUSION CRITERIA Studies containing quantitative measurements of the biomechanical properties of human tissues were included. Studies that primarily focused on dynamic and fluid mechanical properties were excluded. Additionally, studies only containing animal, in silico , or synthetic materials were excluded from this review. METHODS This scoping review followed the JBI methodology for scoping reviews and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Sources of evidence were extracted from CINAHL (EBSCO), IEEE Xplore, MEDLINE (PubMed), Scopus, and engineering conference proceedings. The search was limited to the English language. Two independent reviewers screened titles and abstracts as well as full-text reviews. Any conflicts that arose during screening and full-text review were mediated by a third reviewer. Data extraction was conducted by 2 independent reviewers and discrepancies were mediated through discussion. The results are presented in tabular, figure, and narrative formats. RESULTS Data were extracted from a total of 186 full-text publications. All of the studies, except for 1, were experimental. Included studies came from 33 countries, with the majority coming from the United States. Ex vivo methods were the predominant approach for extracting human tissue samples, and the most commonly studied tissue type was musculoskeletal. In this study, nearly 200 unique biomechanical values were reported, and the most commonly reported value was Young's (elastic) modulus. The most common type of mechanical test performed was tensile testing, and the most common reason for testing human tissues was to characterize biomechanical properties. Although the number of published studies on biomechanical properties of human tissues has increased over the past 20 years, there are many gaps in the literature. Of the 186 included studies, only 7 used human tissues for the design or validation of medical skills training devices. Furthermore, in studies where biomechanical values for human tissues have been obtained, a lack of standardization in engineering assumptions, methodologies, and tissue preparation may implicate the usefulness of these values. CONCLUSIONS This review is the first of its kind to give a broad overview of the biomechanics of human tissues in the published literature. With respect to high-fidelity haptics, there is a large gap in the published literature. Even in instances where biomechanical values are available, comparing or using these values is difficult. This is likely due to the lack of standardization in engineering assumptions, testing methodology, and reporting of the results. It is recommended that journals and experts in engineering fields conduct further research to investigate the feasibility of implementing reporting standards. REVIEW REGISTRATION Open Science Framework https://osf.io/fgb34.
Collapse
Affiliation(s)
- Kyleigh Kriener
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Harrison Whiting
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- School of Clinical Medicine, Royal Brisbane Clinical Unit, The University of Queensland, Brisbane, QLD, Australia
| | - Nicholas Storr
- Gold Coast University Hospital, Southport, QLD Australia
| | - Ryan Homes
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Raushan Lala
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Robert Gabrielyan
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Jasmine Kuang
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Bryn Rubin
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Edward Frails
- Department of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| | - Hannah Sandstrom
- Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA, United States
| | - Christopher Futter
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- Anaesthesia and Intensive Care Program, Herston Biofabrication institute, Brisbane, QLD, Australia
| | - Mark Midwinter
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
2
|
Surface wave analysis of the skin for penetrating and non-penetrating projectile impact in porcine legs. Forensic Sci Med Pathol 2023; 19:34-43. [PMID: 36100841 DOI: 10.1007/s12024-022-00521-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/24/2022] [Indexed: 11/27/2022]
Abstract
Secondary blast injuries may result from high-velocity projectile fragments which ultimately increase medical costs, reduce active work time, and decrease quality of life. The role of skin penetration requires more investigation in energy absorption and surface mechanics for implementation in computational ballistic models. High-speed ballistic penetration studies have not considered penetrating and non-penetrating biomechanical properties of the skin, including radial wave displacement, resultant surface wave speed, or projectile material influence. A helium-pressurized launcher was used to accelerate 3/8″ (9.525 mm) diameter spherical projectiles toward seventeen whole porcine legs from seven pigs (39.53 ± 7.28 kg) at projectile velocities below and above V50. Projectiles included a mix of materials: stainless steel (n = 26), Si3N4 (n = 24), and acetal plastic (n = 24). Tracker video analysis software was used to determine projectile velocity at impact from the perpendicular view and motion of the tissue displacement wave from the in-line view. Average radial wave displacement and surface wave speed were calculated for each projectile material and categorized by penetrating or non-penetrating impacts. Two-sample t-tests determined that non-penetrating projectiles resulted in significantly faster surface wave speeds in porcine skin for stainless steel (p = 0.002), plastic (p = 0.004), and Si3N4 ball bearings (p = 0.014), while ANOVA determined significant differences in radial wave displacement and surface wave speed between projectile materials. Surface wave speed was used to quantify mechanical properties of the skin including elastic modulus, shear modulus, and bulk modulus during ballistic impact, which may be implemented to simulate accurate deformation behavior in computational impact models.
Collapse
|
3
|
Gefen A. Alternatives and preferences for materials in use for pressure ulcer prevention: An experiment-reinforced literature review. Int Wound J 2022; 19:1797-1809. [PMID: 35274443 DOI: 10.1111/iwj.13784] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Revised: 02/21/2022] [Accepted: 02/24/2022] [Indexed: 12/15/2022] Open
Abstract
Alleviation of localised, sustained tissue loads and microclimate management are the most critical performance criteria for materials in use for pressure ulcer prevention, such as in prophylactic dressings, padding or cushioning. These material performance criteria can be evaluated by calculating the extents of matching between the material stiffness (elastic modulus) and the thermal conductivity of the protective dressing, padding or cushioning with the corresponding properties of native skin, separately or in combination. Based on these bioengineering performance criteria, hydrocolloids, which are commonly used for prophylaxis of medical device-related pressure ulcers, exhibit poor stiffness matching with skin. In addition, there is remarkable variability in the modulus and thermal conductivity matching levels of different material types used for pressure ulcer prevention, however, it appears that among the materials tested, hydrogels provide the optimal matching with skin, followed by gels and silicone foams. The stiffness matching for hydrocolloids appears to be inferior even to that of gauze. This article provides quantitative performance criteria and metrics for these evaluations, and grades commonly used material types to biomechanically guide clinicians and industry with regards to the selection of dressings for pressure ulcer prevention, both due to bodyweight forces and as a result of applied medical devices.
Collapse
Affiliation(s)
- Amit Gefen
- Department of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
4
|
Spartacus V, Shojaeizadeh M, Raffault V, Shoults J, Van Wieren K, Sparrey CJ. In vivo soft tissue compressive properties of the human hand. PLoS One 2021; 16:e0261008. [PMID: 34898632 PMCID: PMC8668133 DOI: 10.1371/journal.pone.0261008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 11/22/2021] [Indexed: 12/25/2022] Open
Abstract
Background/Purpose Falls onto outstretched hands are the second most common sports injury and one of the leading causes of upper extremity injury. Injury risk and severity depends on forces being transmitted through the palmar surface to the upper extremity. Although the magnitude and distribution of forces depend on the soft tissue response of the palm, the in vivo properties of palmar tissue have not been characterized. The purpose of this study was to characterize the large deformation palmar soft tissue properties. Methods In vivo dynamic indentations were conducted on 15 young adults (21–29 years) to quantify the soft tissue characteristics of over the trapezium. The effects of loading rate, joint position, tissue thickness and sex on soft tissue responses were assessed. Results Energy absorbed by the soft tissue and peak force were affected by loading rate and joint angle. Energy absorbed was 1.7–2.8 times higher and the peak force was 2–2.75 times higher at high rate loading than quasistatic rates. Males had greater energy absorbed than females but not at all wrist positions. Damping characteristics were the highest in the group with the thickest soft tissue while damping characteristics were the lowest in group with the thinnest soft tissues. Conclusion Palmar tissue response changes with joint position, loading rate, sex, and tissue thickness. Accurately capturing these tissue responses is important for developing effective simulations of fall and injury biomechanics and assessing the effectiveness of injury prevention strategies.
Collapse
Affiliation(s)
- Victoria Spartacus
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
- * E-mail:
| | - Maedeh Shojaeizadeh
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
| | - Vincent Raffault
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
| | - James Shoults
- Science Technical Center, Simon Fraser University, Burnaby, BC, Canada
| | - Ken Van Wieren
- Science Technical Center, Simon Fraser University, Burnaby, BC, Canada
| | - Carolyn J. Sparrey
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
- International Collaboration on Repair Discoveries (ICORD), Vancouver, British Columbia, Canada
| |
Collapse
|
5
|
Grigatti A, Gefen A. What makes a hydrogel-based dressing advantageous for the prevention of medical device-related pressure ulcers. Int Wound J 2021; 19:515-530. [PMID: 34245120 PMCID: PMC8874119 DOI: 10.1111/iwj.13650] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 06/20/2021] [Accepted: 06/21/2021] [Indexed: 12/14/2022] Open
Abstract
The synergistic influences of geometrical, mechanical and thermal mismatches between a skin‐contacting medical device and the skin may cause tissue stress concentrations and sharp temperature gradients, both of which contribute to the risk for medical device‐related pressure ulcers. In this work, we developed an innovative, integrated experimental bioengineering approach encompassing mechanical stiffness, friction and thermal property studies for testing the biomechanical suitability of a hydrogel‐based dressing in prophylaxis of injuries caused by devices. We characterised the viscoelastic stress relaxation of the dressing and determined its long‐term elastic modulus. We further measured the coefficient of friction of the hydrogel‐based dressing at dressing‐device and skin‐dressing interfaces, using a tilting‐table tribometer. Lastly, we measured the thermal conductivity of the dressing, using a heat‐flow meter and infrared thermography‐based method. All measurements considered dry and moist conditions, the latter simulating skin perspiration effects. Our results revealed that the long‐term stiffness and the thermal conductivity of the hydrogel‐based dressing matched the corresponding properties of human skin for both dry and moist conditions. The dressing further demonstrated a relatively high coefficient of friction at its skin‐facing and device‐facing aspects, indicating minimal frictional sliding. All these properties make the above dressing advantageous for prevention of device‐related injuries.
Collapse
Affiliation(s)
- Angela Grigatti
- Department of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Amit Gefen
- Department of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|