1
|
Debuigne M, Gatel L, Chesnel M. Placement of the feline V-gel Advanced supraglottic airway device and tracheal selectivity during controlled mechanical ventilation: a clinical and tomodensitometric evaluation. J Feline Med Surg 2024; 26:1098612X241264725. [PMID: 39320265 PMCID: PMC11456185 DOI: 10.1177/1098612x241264725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/06/2024] [Indexed: 09/26/2024]
Abstract
OBJECTIVES The aims of the study was to assess the placement of the V-gel Advanced (V-gel-A) and to evaluate tracheal selectivity during controlled mechanical ventilation, using CT. METHODS In this prospective clinical study, 20 healthy cats undergoing general anaesthesia for an elective procedure underwent four successive CT scans from the nose to the mid-abdomen: at baseline (no device); after the placement of the V-gel-A, after a controlled mechanical ventilation (CMV) period of 5 mins; and after the placement of an endotracheal tube (ETT). Using both a purpose designed position score and a gas score estimating the quantity of gas in different digestive regions, the position of the V-gel-A and presence of gas in the digestive tract at each step were evaluated. Number of attempts and times required to place the V-gel-A and ETT were recorded and compared. RESULTS The V-gel-A was found to be correctly placed, with position scores of 3/5 in six cats, 4/5 in 13 cats and 5/5 in one cat. Imperfect positioning was due to minor axial rotation or incomplete occlusion of the oesophagus by the tip of the device. The gas scores significantly increased after placement of the V-gel-A compared with baseline and after CMV was initiated. Correct positioning of the device was mostly achieved at the first attempt; no significant difference was found in the time required to place V-gel-A vs ETT, nor in the number of attempts (P >0.05). CONCLUSIONS AND RELEVANCE The V-gel-A was clinically easy to place and use in both spontaneous and controlled ventilation. The device properly fitted the larynx and was never observed to occlude the airway. However, incomplete occlusion of the oesophagus was frequently observed and may lead to a lack of complete tracheal selectivity.
Collapse
|
2
|
Niyatiwatchanchai N, Rattanathanya H, Thengchaisri N. Comparative study of ventilation techniques with supraglottic airway devices in cats: volume-controlled vs pressure-controlled techniques. J Feline Med Surg 2024; 26:1098612X231225353. [PMID: 38294899 PMCID: PMC10949876 DOI: 10.1177/1098612x231225353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
OBJECTIVES This study compared the effectiveness of a new supraglottic airway device (SGAD) in cats undergoing anaesthesia using two types of mechanical ventilation: volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV). METHODS A total of 13 healthy cats (five male, eight female; median age 2 years [range 1-3]) were randomly allocated to either VCV or PCV. Five tidal volumes (6, 8, 10, 12 and 14 ml/kg) and five peak inspiratory pressures (4, 5, 6, 7 and 8 cmH2O) were randomly applied with a minute ventilation of 100 ml/kg/min. Various parameters, such as blood pressure, gas leakage, end-tidal CO2 (ETCO2) and work of breathing (WOB), were measured while using VCV or PCV. RESULTS The occurrence of hypotension (mean arterial blood pressure <60 mmHg) was slightly less frequent with VCV (38 events, 65 ventilating sessions) than with PCV (40 events, 65 ventilating sessions), but this difference did not reach statistical significance (P = 0.429). The number of leakages did not differ between the VCV group (3 events, 65 ventilating sessions) and the PCV group (3 events, 65 ventilating sessions) (P = 1.000). Hypercapnia was identified when using VCV (10 events, 65 ventilating sessions) less frequently than when using PCV (17 events, 65 ventilating sessions), but this difference did not reach statistical significance (P = 0.194). The study found a significantly higher WOB in the PCV group compared with the VCV group (P <0.034). CONCLUSIONS AND RELEVANCE The present results suggested that both VCV and PCV can be used with an SGAD during anaesthesia, with VCV preferred for prolonged mechanical ventilation due to its lower workload. Adjusting tidal volume or inspiratory pressure corrects hypercapnia.
Collapse
Affiliation(s)
- Nutawan Niyatiwatchanchai
- Surgery Unit, Kasetsart University Veterinary Teaching Hospital, Faculty of Veterinary Medicine, Kasetsart University, Bangkok, Thailand
| | - Hathaipat Rattanathanya
- HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Lak Si, Bangkok, Thailand
| | - Naris Thengchaisri
- Department of Companion Animal Clinical Sciences, Faculty of Veterinary Medicine, Kasetsart University, Bangkok, Thailand
| |
Collapse
|
3
|
A PRELIMINARY STUDY TO EVALUATE THE EFFECTIVENESS OF LARYNGEAL MASK AIRWAYS IN ANESTHETIZED BIGHORN SHEEP (OVIS CANADENSIS) LAMBS. J Zoo Wildl Med 2022; 53:537-544. [DOI: 10.1638/2022-0019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/19/2022] [Indexed: 11/21/2022] Open
|
4
|
Hecker-Turkovic K, Hartmann K, Dörfelt R. Success of placement and complications during v-gel placement and maintenance of anaesthesia. J Feline Med Surg 2022; 24:800-805. [PMID: 34663126 PMCID: PMC9315189 DOI: 10.1177/1098612x211050612] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVES Airway management during anaesthesia in cats is always a demanding task and is associated with several complications. The aim of this study was to evaluate the practicability and complications during feline-specific laryngeal mask placement in anaesthetised cats as an alternative to endotracheal intubation. METHODS In this prospective clinical study, laryngeal masks were placed in 148 anaesthetised cats. Success of placement was evaluated by capnography. RESULTS Placement was possible at the first attempt in 136 cats, at the second attempt in eight cats and at the third attempt in one cat. In one cat, placement was not possible. Two cats were excluded. Failure to position the laryngeal mask at the first attempt was not different between laryngeal mask sizes (P = 0.313) or positioning during placement (P = 0.406). In nine cats, the laryngeal mask dislocated during the procedure. Dislocation occurred more often in the dorsal position than in the sternal (P = 0.018) and right lateral positions (P = 0.046). Mucous obstruction of the laryngeal mask occurred in one of these cats and regurgitation in another. Material-related issues, such as disconnection of the parts of the laryngeal mask and leakage of the balloon, were observed in 2/8 laryngeal masks. CONCLUSIONS AND RELEVANCE The placement of a feline-specific laryngeal mask was easy to perform. In about 7% of the cases, replacement of the device was required due to mispositioning or dislocation. Full monitoring, including capnography, should be provided to uncover dislocation and airway obstruction immediately.
Collapse
Affiliation(s)
| | - Katrin Hartmann
- Clinic of Small Animal Medicine, Ludwig Maximilian University of Munich, Munich, Germany
| | - René Dörfelt
- Clinic of Small Animal Medicine, Ludwig Maximilian University of Munich, Munich, Germany
| |
Collapse
|
5
|
Niyatiwatchanchai N, Thengchaisri N. Clinical assessment of the efficacy of supraglottic airway devices compared with endotracheal tubes in cats during volume-controlled ventilation. J Vet Sci 2020; 21:e27. [PMID: 32233135 PMCID: PMC7113573 DOI: 10.4142/jvs.2020.21.e27] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Revised: 07/19/2019] [Accepted: 11/30/2019] [Indexed: 12/26/2022] Open
Abstract
The efficacies of a supraglottic airway device (SGAD) and an endotracheal tube (ETT) in cats under general anesthesia with volume-controlled ventilation (VCV) were compared. Thirty healthy cats were randomly allocated for airway control using either an SGAD or an ETT. Five tidal volumes (6, 8, 10, 12, and 14 mL/kg) were randomly tested, and respiratory rates were adjusted to achieve a minute ventilation of 100 mL/kg/min. The dose of propofol necessary to insert the SGAD or ETT, the static respiratory pressure, leakage during VCV, and end tidal CO2 (ETCO2) were recorded. Dosages of propofol and static respiratory measurements for the SGAD and ETT groups were compared using a t-test. The distribution of leakages and hypercapnia (ETCO2 > 45 mmHg) were compared using Fisher's exact test. A significance level of p < 0.05 was established. No significant difference in dose of propofol was observed between the SGAD and ETT groups (7.1 ± 1.0, 7.3 ± 1.7 mg/kg; p = 0.55). Static resistance pressure of the SGAD (22.0 ± 8.1 cmH2O/L/sec) was significantly lower than that of the ETT (36.6 ± 12.9 cmH2O/L/sec; p < 0.01). Of the 75 trials, leakage was more frequent when using an SGAD (8 events) than when using an ETT (1 event; p = 0.03). Hypercapnia occurred more frequently with SGAD (18 events) than with ETT (3 events; p < 0.01). Although intubation with an ETT is the gold standard in small animal anesthesia, the use of an SGAD can reduce airway resistance and the work of breathing. Nonetheless, SGAD had more dead space and the tidal volume for VCV needs adjustment.
Collapse
Affiliation(s)
| | - Naris Thengchaisri
- Department of Companion Animal Clinical Sciences, Kasetsart University, Bangkok 10900, Thailand.
| |
Collapse
|
6
|
Comolli J, Schnellbacher R, Beaufrere H, Blas-Machado U, Quandt J, Mayer J, Divers SJ. Comparison of endoscopic endotracheal intubation and the v-gel supraglottic airway device for spontaneously ventilating New Zealand white rabbits undergoing ovariohysterectomy. Vet Rec 2020; 187:e84. [PMID: 32690763 DOI: 10.1136/vr.105746] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 04/27/2020] [Accepted: 06/17/2020] [Indexed: 12/17/2022]
Abstract
BACKGROUND Due to the technical difficulties with endotracheal intubation of rabbits, a prospective, randomised, controlled study was performed to compare a rabbit-specific supraglottic airway device (SGAD), the v-gel, with endoscopic endotracheal intubation (EEI) in spontaneously breathing rabbits undergoing ovariohysterectomy. METHODS Fourteen adult female New Zealand white rabbits were randomly allocated to one of two groups based on the method of airway establishment: EEI or v-gel SGAD. Anaesthesia was induced with ketamine and xylazine and maintained using isoflurane in 100 per cent oxygen. Comparisons were made between groups based on placement time of endotracheal tube/SGAD, number of attempts and adjustments, the necessity to increase isoflurane concentrations to maintain a surgical plane of anaesthesia, arterial blood gas values, gross laryngeal evaluation, and laryngotracheal histopathology. RESULTS Both techniques resulted in elevated arterial pCO2 levels, but the v-gel was associated with more elevated pCO2 in comparison with EEI (P=0.045). Airway trauma was histologically present but clinically negligible in both groups, with no statistically significant differences observed between techniques (P>0.05). Placement time of the v-gel was significantly faster (P=0.003) and required less technical skill than EEI, but was more easily displaced when changing the animal's position (P=0.004). CONCLUSION The v-gel is a practical alternative to EEI for securing the airway of healthy spontaneously ventilating rabbits, provided a capnograph is utilised to ensure continuous placement. Both airway techniques appear safe and effective with few complications, as long as intermittent positive pressure ventilation can be employed to correct hypercapnia.
Collapse
Affiliation(s)
- Jessica Comolli
- Department of Small Animal Medicine and Surgery (Zoological Medicine), College of Veterinary Medicine, University of Georgia, Athens, Georgia, USA
| | - Rodney Schnellbacher
- Department of Small Animal Medicine and Surgery (Zoological Medicine), College of Veterinary Medicine, University of Georgia, Athens, Georgia, USA
| | - Hugues Beaufrere
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada
| | - Uriel Blas-Machado
- Department of Pathology, College of Veterinary Medicine, University of Gerogia, Athens, Georgia, USA
| | - Jane Quandt
- Department of Small Animal Medicine and Surgery (Anesthesia), College of Veterinary Medicine, University of Georgia, Athens, Georgia, USA
| | - Jörg Mayer
- Department of Small Animal Medicine and Surgery (Zoological Medicine), College of Veterinary Medicine, University of Georgia, Athens, Georgia, USA
| | - Stephen J Divers
- Department of Small Animal Medicine and Surgery (Zoological Medicine), College of Veterinary Medicine, University of Georgia, Athens, Georgia, USA
| |
Collapse
|
7
|
Affiliation(s)
- Adrianna Skarbek
- Anderson Moores Veterinary Specialists, The Granary, Bunstead Barns, Poles Lane, Hursley, Winchaster, Hampshire, SO21 2LL
| | - Karla Borland
- Anderson Moores Veterinary Specialists, The Granary, Bunstead Barns, Poles Lane, Hursley, Winchaster, Hampshire, SO21 2LL
| |
Collapse
|
8
|
Iizuka T, Masui K, Kanazawa H, Nishimura R. Comparison of plasma propofol concentration for apnea, response to mechanical ventilation, and airway device between endotracheal tube and supraglottic airway device in Beagles. J Vet Med Sci 2018; 80:1420-1423. [PMID: 30012918 PMCID: PMC6160887 DOI: 10.1292/jvms.17-0468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The relationships between propofol plasma concentrations and the pharmacodynamic endpoints may differ according to a type of airway device. To clarify these relationships in different
airway devices would be useful to avoid the complication such as apnea and intraoperative awareness. The aim of this study was to investigate the influence of difference of airway device on
propofol requirement during maintenance of anesthesia in dogs. We compared the influence of airway devices on the plasma propofol concentrations for apnea, response to mechanical
ventilation, and response to airway device between endotracheal tube (ETT) and supraglottic airway device (SGAD) in Beagles. The pharmacodynamic effects were repeatedly assessed at varying
propofol concentrations. The plasma concentrations (mean ± SD) of propofol in the ETT and SGAD groups were 10.2 ± 1.8 and 10.9 ± 2.4 µg/ml for apnea
(P=0.438), 7.9 ± 1.2 and 7.4 ± 1.5 µg/ml for response to mechanical ventilation (P=0.268), and 5.2 ± 0.7 and 5.4 ± 1.5
µg/ml for response to airway device (P=0.580), respectively. Required propofol concentration during maintenance of anesthesia may be
similar between ETT and SGAD. Without moderate to strong stimuli such as airway device insertion or painful stimulation during surgery, the type of airway device may have little impact on
required propofol concentration during maintenance of anesthesia in dogs.
Collapse
Affiliation(s)
- Tomoya Iizuka
- Laboratory of Veterinary Surgery, Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan
| | - Kenichi Masui
- Department of Anesthesiology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8666, Japan
| | - Hideko Kanazawa
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato-ku, Tokyo 105-8512, Japan
| | - Ryohei Nishimura
- Laboratory of Veterinary Surgery, Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan
| |
Collapse
|
9
|
Wenger S, Müllhaupt D, Ohlerth S, Prasse S, Klein K, da Silva Valente B, Mosing M. Experimental evaluation of four airway devices in anaesthetized New Zealand White rabbits. Vet Anaesth Analg 2017; 44:529-537. [DOI: 10.1016/j.vaa.2016.05.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 04/28/2016] [Accepted: 05/03/2016] [Indexed: 10/20/2022]
|
10
|
Griffin B, Bushby PA, McCobb E, White SC, Rigdon-Brestle YK, Appel LD, Makolinski KV, Wilford CL, Bohling MW, Eddlestone SM, Farrell KA, Ferguson N, Harrison K, Howe LM, Isaza NM, Levy JK, Looney A, Moyer MR, Robertson SA, Tyson K. The Association of Shelter Veterinarians' 2016 Veterinary Medical Care Guidelines for Spay-Neuter Programs. J Am Vet Med Assoc 2017; 249:165-88. [PMID: 27379593 DOI: 10.2460/javma.249.2.165] [Citation(s) in RCA: 73] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
As community efforts to reduce the overpopulation and euthanasia of unwanted and unowned cats and dogs have increased, many veterinarians have increasingly focused their clinical efforts on the provision of spay-neuter services. Because of the wide range of geographic and demographic needs, a wide variety of spay-neuter programs have been developed to increase delivery of services to targeted populations of animals, including stationary and mobile clinics, MASH-style operations, shelter services, community cat programs, and services provided through private practitioners. In an effort to promote consistent, high-quality care across the broad range of these programs, the Association of Shelter Veterinarians convened a task force of veterinarians to develop veterinary medical care guidelines for spay-neuter programs. These guidelines consist of recommendations for general patient care and clinical procedures, preoperative care, anesthetic management, surgical procedures, postoperative care, and operations management. They were based on current principles of anesthesiology, critical care medicine, infection control, and surgical practice, as determined from published evidence and expert opinion. They represent acceptable practices that are attainable in spay-neuter programs regardless of location, facility, or type of program. The Association of Shelter Veterinarians envisions that these guidelines will be used by the profession to maintain consistent veterinary medical care in all settings where spay-neuter services are provided and to promote these services as a means of reducing sheltering and euthanasia of cats and dogs.
Collapse
|
11
|
Prasse SA, Schrack J, Wenger S, Mosing M. Clinical evaluation of the v-gel supraglottic airway device in comparison with a classical laryngeal mask and endotracheal intubation in cats during spontaneous and controlled mechanical ventilation. Vet Anaesth Analg 2016; 43:55-62. [DOI: 10.1111/vaa.12261] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2014] [Accepted: 12/04/2014] [Indexed: 11/28/2022]
|
12
|
Barletta M, Kleine SA, Quandt JE. Assessment of v-gel supraglottic airway device placement in cats performed by inexperienced veterinary students. Vet Rec 2015; 177:523. [DOI: 10.1136/vr.103407] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2015] [Indexed: 12/26/2022]
Affiliation(s)
- M. Barletta
- Department of Large Animal Medicine; College of Veterinary Medicine, University of Georgia; Athens GA 30602 USA
| | - S. A. Kleine
- Department of Small Animal Medicine & Surgery; College of Veterinary Medicine, University of Georgia; Athens GA 30602 USA
| | - J. E. Quandt
- Department of Small Animal Medicine & Surgery; College of Veterinary Medicine, University of Georgia; Athens GA 30602 USA
| |
Collapse
|
13
|
Richardson D. A comparison of the v-gel® supraglottic airway device and non-cuffed endotracheal tube in the time to first capnograph trace during anaesthetic induction in rabbits. ACTA ACUST UNITED AC 2015. [DOI: 10.12968/vetn.2015.6.7.426] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|