1
|
Martin NRW, Passey SL, Player DJ, Khodabukus A, Ferguson RA, Sharples AP, Mudera V, Baar K, Lewis MP. Factors affecting the structure and maturation of human tissue engineered skeletal muscle. Biomaterials 2013; 34:5759-65. [PMID: 23643182 DOI: 10.1016/j.biomaterials.2013.04.002] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Accepted: 04/03/2013] [Indexed: 11/15/2022]
Abstract
Tissue engineered skeletal muscle has great utility in experimental studies of physiology, clinical testing and its potential for transplantation to replace damaged tissue. Despite recent work in rodent tissue or cell lines, there is a paucity of literature concerned with the culture of human muscle derived cells (MDCs) in engineered constructs. Here we aimed to tissue engineer for the first time in the literature human skeletal muscle in self-assembling fibrin hydrogels and determine the effect of MDC seeding density and myogenic proportion on the structure and maturation of the constructs. Constructs seeded with 4 × 10(5) MDCs assembled to a greater extent than those at 1 × 10(5) or 2 × 10(5), and immunostaining revealed a higher fusion index and a higher density of myotubes within the constructs, showing greater structural semblance to in vivo tissue. These constructs primarily expressed perinatal and slow type I myosin heavy chain mRNA after 21 days in culture. In subsequent experiments MACS(®) technology was used to separate myogenic and non-myogenic cells from their heterogeneous parent population and these cells were seeded at varying myogenic (desmin +) proportions in fibrin based constructs. Only in the constructs seeded with 75% desmin + cells was there evidence of striations when immunostained for slow myosin heavy chain compared with constructs seeded with 10 or 50% desmin + cells. Overall, this work reveals the importance of cell number and myogenic proportions in tissue engineering human skeletal muscle with structural resemblance to in vivo tissue.
Collapse
Affiliation(s)
- Neil R W Martin
- Musculoskeletal Biology Research Group, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, Leicestershire LE113TU, UK
| | | | | | | | | | | | | | | | | |
Collapse
|
2
|
de Vries RBM, Leenaars M, Tra J, Huijbregtse R, Bongers E, Jansen JA, Gordijn B, Ritskes-Hoitinga M. The potential of tissue engineering for developing alternatives to animal experiments: a systematic review. J Tissue Eng Regen Med 2013; 9:771-8. [PMID: 23554402 DOI: 10.1002/term.1703] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2012] [Revised: 11/28/2012] [Accepted: 12/20/2012] [Indexed: 01/18/2023]
Abstract
An underexposed ethical issue raised by tissue engineering is the use of laboratory animals in tissue engineering research. Even though this research results in suffering and loss of life in animals, tissue engineering also has great potential for the development of alternatives to animal experiments. With the objective of promoting a joint effort of tissue engineers and alternative experts to fully realise this potential, this study provides the first comprehensive overview of the possibilities of using tissue-engineered constructs as a replacement of laboratory animals. Through searches in two large biomedical databases (PubMed, Embase) and several specialised 3R databases, 244 relevant primary scientific articles, published between 1991 and 2011, were identified. By far most articles reviewed related to the use of tissue-engineered skin/epidermis for toxicological applications such as testing for skin irritation. This review article demonstrates, however, that the potential for the development of alternatives also extends to other tissues such as other epithelia and the liver, as well as to other fields of application such as drug screening and basic physiology. This review discusses which impediments need to be overcome to maximise the contributions that the field of tissue engineering can make, through the development of alternative methods, to the reduction of the use and suffering of laboratory animals.
Collapse
Affiliation(s)
- Rob B M de Vries
- 3R Research Centre / SYRCLE, Central Animal Laboratory, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - Marlies Leenaars
- 3R Research Centre / SYRCLE, Central Animal Laboratory, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - Joppe Tra
- Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | | | - Erik Bongers
- Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - John A Jansen
- Department of Periodontology and Biomaterials, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - Bert Gordijn
- Institute of Ethics, Dublin City University, Dublin, Ireland
| | - Merel Ritskes-Hoitinga
- 3R Research Centre / SYRCLE, Central Animal Laboratory, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| |
Collapse
|
3
|
Zatti S, Zoso A, Serena E, Luni C, Cimetta E, Elvassore N. Micropatterning topology on soft substrates affects myoblast proliferation and differentiation. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2012; 28:2718-2726. [PMID: 22217143 DOI: 10.1021/la204776e] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Micropatterning techniques and substrate engineering are becoming useful tools to investigate several aspects of cell-cell interaction biology. In this work, we rationally study how different micropatterning geometries can affect myoblast behavior in the early stage of in vitro myogenesis. Soft hydrogels with physiological elastic modulus (E = 15 kPa) were micropatterned in parallel lanes (100, 300, and 500 μm width) resulting in different local and global myoblast densities. Proliferation and differentiation into multinucleated myotubes were evaluated for murine and human myoblasts. Wider lanes showed a decrease in murine myoblast proliferation: (69 ± 8)% in 100 μm wide lanes compared to (39 ± 7)% in 500 μm lanes. Conversely, fusion index increased in wider lanes: from (46 ± 7)% to (66 ± 7)% for murine myoblasts, and from (15 ± 3)% to (36 ± 2)% for human primary myoblasts, using a patterning width of 100 and 500 μm, respectively. These results are consistent with both computational modeling data and conditioned medium experiments, which demonstrated that wider lanes favor the accumulation of endogenous secreted factors. Interestingly, human primary myoblast proliferation is not affected by patterning width, which may be because the high serum content of their culture medium overrides the effect of secreted factors. These data highlight the role of micropatterning in shaping the cellular niche through secreted factor accumulation, and are of paramount importance in rationally understanding myogenesis in vitro for the correct design of in vitro skeletal muscle models.
Collapse
Affiliation(s)
- Susi Zatti
- Department of Industrial Engineering (DII), University of Padova, via Marzolo 9, 35131 Padova, Italy
| | | | | | | | | | | |
Collapse
|
4
|
Zijdewind I, Thomas CK. Firing patterns of spontaneously active motor units in spinal cord-injured subjects. J Physiol 2012; 590:1683-97. [PMID: 22310313 DOI: 10.1113/jphysiol.2011.220103] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Involuntary motor unit activity at low rates is common in hand muscles paralysed by spinal cord injury. Our aim was to describe these patterns of motor unit behaviour in relation to motoneurone and motor unit properties. Intramuscular electromyographic activity (EMG), surface EMG and force were recorded for 30 min from thenar muscles of nine men with chronic cervical SCI. Motor units fired for sustained periods (>10 min) at regular (coefficient of variation ≤ 0.15, CV, n =19 units) or irregular intervals (CV>0.15, n =14). Regularly firing units started and stopped firing independently suggesting that intrinsic motoneurone properties were important for recruitment and derecruitment. Recruitment (3.6 Hz, SD 1.2), maximal (10.2 Hz, SD 2.3, range: 7.5-15.4 Hz) and derecruitment frequencies were low (3.3 Hz, SD 1.6), as were firing rate increases after recruitment (~20 intervals in 3 s). Once active, firing often covaried, promoting the idea that units received common inputs.Half of the regularly firing units showed a very slow decline (>40 s) in discharge before derecruitment and had interspike intervals longer than their estimated after hyperpolarisation potential (AHP) duration (estimated by death rate and breakpoint analyses). The other units were derecruited more abruptly and had shorter estimated AHP durations. Overall, regularly firing units had longer estimated AHP durations and were weaker than irregularly firing units, suggesting they were lower threshold units. Sustained firing of units at regular rates may reflect activation of persistent inward currents, visible here in the absence of voluntary drive, whereas irregularly firing units may only respond to synaptic noise.
Collapse
Affiliation(s)
- Inge Zijdewind
- Department of Neuroscience, Medical Physiology, University Medical Center Groningen, University of Groningen, The Netherlands
| | | |
Collapse
|
5
|
Multiscale Fibrous Scaffolds in Regenerative Medicine. ADVANCES IN POLYMER SCIENCE 2011. [DOI: 10.1007/12_2011_163] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
|
6
|
Bouten C, Dankers P, Driessen-Mol A, Pedron S, Brizard A, Baaijens F. Substrates for cardiovascular tissue engineering. Adv Drug Deliv Rev 2011; 63:221-41. [PMID: 21277921 DOI: 10.1016/j.addr.2011.01.007] [Citation(s) in RCA: 168] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2010] [Revised: 12/26/2010] [Accepted: 01/14/2011] [Indexed: 12/29/2022]
Abstract
Cardiovascular tissue engineering aims to find solutions for the suboptimal regeneration of heart valves, arteries and myocardium by creating 'living' tissue replacements outside (in vitro) or inside (in situ) the human body. A combination of cells, biomaterials and environmental cues of tissue development is employed to obtain tissues with targeted structure and functional properties that can survive and develop within the harsh hemodynamic environment of the cardiovascular system. This paper reviews the up-to-date status of cardiovascular tissue engineering with special emphasis on the development and use of biomaterial substrates. Key requirements and properties of these substrates, as well as methods and readout parameters to test their efficacy in the human body, are described in detail and discussed in the light of current trends toward designing biologically inspired microenviroments for in situ tissue engineering purposes.
Collapse
|
7
|
Modularly assembled porous cell-laden hydrogels. Biomaterials 2010; 31:4918-25. [DOI: 10.1016/j.biomaterials.2010.02.069] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2010] [Accepted: 02/26/2010] [Indexed: 11/19/2022]
|
8
|
Lee EJ, Kim DE, Azeloglu EU, Costa KD. Engineered cardiac organoid chambers: toward a functional biological model ventricle. Tissue Eng Part A 2008; 14:215-25. [PMID: 18333774 DOI: 10.1089/tea.2007.0351] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
A growing area in the field of tissue engineering is the development of tissue equivalents as model systems for in vitro experimentation and high-throughput screening applications. Although a variety of strategies have been developed to enhance the structure and function of engineered cardiac tissues, an inherent limitation with traditional myocardial patches is that they do not permit evaluation of the fundamental relationships between pressure and volume that characterize global contractile function of the heart. Therefore, in the following study we introduce fully biological, living engineered cardiac organoids, or simplified heart chambers, that beat spontaneously, develop pressure, eject fluid, contain residual stress, exhibit a functional Frank-Starling mechanism, and generate positive stroke work. We also demonstrate regional variations in pump function following local cryoinjury, yielding a novel engineered tissue model of myocardial infarction. With the unique ability to directly evaluate relevant pressure-volume characteristics and regulate wall stress, this organoid chamber culture system provides a flexible platform for developing a controllable biomimetic cardiac niche environment that can be adapted for a variety of high-throughput and long-term investigations of cardiac pump function.
Collapse
Affiliation(s)
- Eun Jung Lee
- Department of Anesthesiology, Yale University, New Haven, Connecticut, USA
| | | | | | | |
Collapse
|
9
|
Wilson K, Molnar P, Hickman J. Integration of functional myotubes with a Bio-MEMS device for non-invasive interrogation. LAB ON A CHIP 2007; 7:920-2. [PMID: 17594013 DOI: 10.1039/b617939h] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
We have developed a biological micro-electromechanical system (Bio-MEMS) device consisting of surface-modified microfabricated silicon cantilevers and an AFM detection apparatus for the study of cultured myotubes. With this system we are able to selectively stimulate the myotubes as well as report on a variety of physiological properties of the myotubes in real time and in a high-throughput manner. This system will serve as the foundation for future work integrating multiple tissue types for the creation of Bio-MEMS analogues of complex tissues and biological circuits.
Collapse
Affiliation(s)
- Kerry Wilson
- NanoScience Technology Center, University of Central Florida, Orlando, FL 32826, USA.
| | | | | |
Collapse
|
10
|
Häger-Ross CK, Klein CS, Thomas CK. Twitch and Tetanic Properties of Human Thenar Motor Units Paralyzed by Chronic Spinal Cord Injury. J Neurophysiol 2006; 96:165-74. [PMID: 16611836 DOI: 10.1152/jn.01339.2005] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Little is known about how human motor units respond to chronic paralysis. Our aim was to record surface electromyographic (EMG) signals, twitch forces, and tetanic forces from paralyzed motor units in the thenar muscles of individuals ( n = 12) with chronic (1.5–19 yr) cervical spinal cord injury (SCI). Each motor unit was activated by intraneural stimulation of its motor axon using single pulses and trains of pulses at frequencies between 5 and 100 Hz. Paralyzed motor units ( n = 48) had small EMGs and weak tetanic forces ( n = 32 units) but strong twitch forces, resulting in half-maximal force being achieved at a median of only 8 Hz. The distributions for cumulative twitch and tetanic forces also separated less for paralyzed units than for control units, indicating that increases in stimulation frequency made a smaller relative contribution to the total force output in paralyzed muscles. Paralysis also induced slowing of conduction velocities, twitch contraction times and EMG durations. However, the elevated ratios between the twitch and the tetanic forces, but not contractile speed, correlated significantly with the extent to which unit force summated in response to different frequencies of stimulation. Despite changes in the absolute values of many electrical and mechanical properties of paralyzed motor units, most of the distributions shifted uniformly relative to those of thenar units obtained from control subjects. Thus human thenar muscles paralyzed by SCI retain a population of motor units with heterogeneous contractile properties because chronic paralysis influenced all of the motor units similarly.
Collapse
Affiliation(s)
- C K Häger-Ross
- The Miami Project to Cure Paralysis, Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, FL 33136-2104, USA
| | | | | |
Collapse
|