1
|
Durcan C, Hossain M, Chagnon G, Perić D, Girard E. Mechanical experimentation of the gastrointestinal tract: a systematic review. Biomech Model Mechanobiol 2024; 23:23-59. [PMID: 37935880 PMCID: PMC10901955 DOI: 10.1007/s10237-023-01773-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 09/10/2023] [Indexed: 11/09/2023]
Abstract
The gastrointestinal (GI) organs of the human body are responsible for transporting and extracting nutrients from food and drink, as well as excreting solid waste. Biomechanical experimentation of the GI organs provides insight into the mechanisms involved in their normal physiological functions, as well as understanding of how diseases can cause disruption to these. Additionally, experimental findings form the basis of all finite element (FE) modelling of these organs, which have a wide array of applications within medicine and engineering. This systematic review summarises the experimental studies that are currently in the literature (n = 247) and outlines the areas in which experimentation is lacking, highlighting what is still required in order to more fully understand the mechanical behaviour of the GI organs. These include (i) more human data, allowing for more accurate modelling for applications within medicine, (ii) an increase in time-dependent studies, and (iii) more sophisticated in vivo testing methods which allow for both the layer- and direction-dependent characterisation of the GI organs. The findings of this review can also be used to identify experimental data for the readers' own constitutive or FE modelling as the experimental studies have been grouped in terms of organ (oesophagus, stomach, small intestine, large intestine or rectum), test condition (ex vivo or in vivo), number of directions studied (isotropic or anisotropic), species family (human, porcine, feline etc.), tissue condition (intact wall or layer-dependent) and the type of test performed (biaxial tension, inflation-extension, distension (pressure-diameter), etc.). Furthermore, the studies that investigated the time-dependent (viscoelastic) behaviour of the tissues have been presented.
Collapse
Affiliation(s)
- Ciara Durcan
- Zienkiewicz Centre for Modelling, Data and AI, Faculty of Science and Engineering, Swansea University, Swansea, SA1 8EN, UK
- Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, 38000, Grenoble, France
| | - Mokarram Hossain
- Zienkiewicz Centre for Modelling, Data and AI, Faculty of Science and Engineering, Swansea University, Swansea, SA1 8EN, UK.
| | - Grégory Chagnon
- Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, 38000, Grenoble, France
| | - Djordje Perić
- Zienkiewicz Centre for Modelling, Data and AI, Faculty of Science and Engineering, Swansea University, Swansea, SA1 8EN, UK
| | - Edouard Girard
- Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, 38000, Grenoble, France
- Laboratoire d'Anatomie des Alpes Françaises, Université Grenoble Alpes, Grenoble, France
| |
Collapse
|
2
|
Fahmy Y, Trabia MB, Ward B, Gallup L, Froehlich M. Development of an Anisotropic Hyperelastic Material Model for Porcine Colorectal Tissues. Bioengineering (Basel) 2024; 11:64. [PMID: 38247941 PMCID: PMC10813287 DOI: 10.3390/bioengineering11010064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 01/01/2024] [Accepted: 01/05/2024] [Indexed: 01/23/2024] Open
Abstract
Many colonic surgeries include colorectal anastomoses whose leaks may be life-threatening, affecting thousands of patients annually. Various studies propose that mechanical interaction between the staples and neighboring tissues may play an important role in anastomotic leakage. Therefore, understanding the mechanical behavior of colorectal tissue is essential to characterizing the reasons for this type of failure. So far, experimental data characterizing the mechanical properties of colorectal tissue have been few and inconsistent, which has significantly limited understanding their behavior. This research proposes an approach to developing an anisotropic hyperelastic material model for colorectal tissues based on uniaxial testing of freshly harvested porcine specimens, which were collected from several age- and weight-matched pigs. The specimens were extracted from the same colon tract of each pig along their circumferential and longitudinal orientations. We propose a constitutive model combining Yeoh isotropic hyperelastic material with fibers oriented in two directions to account for the hyperelastic and anisotropic nature of colorectal tissues. Experimental data were used to accurately determine the model's coefficients (circumferential, R2 = 0.9968; longitudinal, R2 = 0.9675). The results show that the proposed model can be incorporated into a finite element model that can simulate procedures such as colorectal anastomoses reliably.
Collapse
Affiliation(s)
- Youssef Fahmy
- Department of Mechanical Engineering, Howard R. Hughes College of Engineering, University of Nevada, Las Vegas, NV 89154, USA; (Y.F.); (L.G.)
| | - Mohamed B. Trabia
- Department of Mechanical Engineering, Howard R. Hughes College of Engineering, University of Nevada, Las Vegas, NV 89154, USA; (Y.F.); (L.G.)
| | - Brian Ward
- Department of Surgery, Kirk Kerkorian School of Medicine, University of Nevada, Las Vegas, NV 89154, USA; (B.W.); (M.F.)
| | - Lucas Gallup
- Department of Mechanical Engineering, Howard R. Hughes College of Engineering, University of Nevada, Las Vegas, NV 89154, USA; (Y.F.); (L.G.)
| | - Mary Froehlich
- Department of Surgery, Kirk Kerkorian School of Medicine, University of Nevada, Las Vegas, NV 89154, USA; (B.W.); (M.F.)
| |
Collapse
|
3
|
Bonaldi L, Berardo A, Pirri C, Stecco C, Carniel EL, Fontanella CG. Mechanical Characterization of Human Fascia Lata: Uniaxial Tensile Tests from Fresh-Frozen Cadaver Samples and Constitutive Modelling. Bioengineering (Basel) 2023; 10:bioengineering10020226. [PMID: 36829719 PMCID: PMC9952725 DOI: 10.3390/bioengineering10020226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/15/2023] [Accepted: 02/04/2023] [Indexed: 02/10/2023] Open
Abstract
Human Fascia Lata (FL) is a connective tissue with a multilayered organization also known as aponeurotic fascia. FL biomechanics is influenced by its composite structure formed by fibrous layers (usually two) separated by loose connective tissue. In each layer, most of the collagen fibers run parallel in a distinct direction (with an interlayer angle that usually ranges from 75-80°), mirroring the fascia's ability to adapt and withstand specific tensile loads. Although FL is a key structure in several musculoskeletal dysfunctions and in tissue engineering, literature still lacks the evidence that proves tissue anisotropy according to predominant collagen fiber directions. For this purpose, this work aims to analyze the biomechanical properties of ex-vivo FL (collected from fresh-frozen human donors) by performing uniaxial tensile tests in order to highlight any differences with respect to loading directions. The experimental outcomes showed a strong anisotropic behavior in accordance with principal collagen fibers directions, which characterize the composite structure. These findings have been implemented to propose a first constitutive model able to mimic the intra- and interlayer interactions. Both approaches could potentially support surgeons in daily practices (such as graft preparation and placement), engineers during in silico simulation, and physiotherapists during musculoskeletal rehabilitation, to customize a medical intervention based on each specific patient and clinical condition.
Collapse
Affiliation(s)
- Lorenza Bonaldi
- Department of Civil, Environmental and Architectural Engineering, University of Padova, 35131 Padova, Italy
| | - Alice Berardo
- Department of Civil, Environmental and Architectural Engineering, University of Padova, 35131 Padova, Italy
- Department of Biomedical Sciences, University of Padova, 35131 Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Correspondence:
| | - Carmelo Pirri
- Department of Neuroscience, Institute of Human Anatomy, University of Padova, 35121 Padova, Italy
| | - Carla Stecco
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Department of Neuroscience, Institute of Human Anatomy, University of Padova, 35121 Padova, Italy
| | - Emanuele Luigi Carniel
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Department of Industrial Engineering, University of Padova, 35131 Padova, Italy
| | - Chiara Giulia Fontanella
- Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
- Department of Industrial Engineering, University of Padova, 35131 Padova, Italy
| |
Collapse
|
4
|
Biomechanics of Hollow Organs: Experimental Testing and Computational Modeling. Bioengineering (Basel) 2023; 10:bioengineering10020175. [PMID: 36829669 PMCID: PMC9952441 DOI: 10.3390/bioengineering10020175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 01/24/2023] [Indexed: 01/31/2023] Open
Abstract
Hollow organs are visceral organs that are hollow tubes or pouches (such as the intestine or the stomach, respectively) or that include a cavity (such as the heart) and which subserve a vital function [...].
Collapse
|
5
|
Patel B, Gizzi A, Hashemi J, Awakeem Y, Gregersen H, Kassab G. Biomechanical constitutive modeling of the gastrointestinal tissues: a systematic review. MATERIALS & DESIGN 2022; 217:110576. [PMID: 35935127 PMCID: PMC9351365 DOI: 10.1016/j.matdes.2022.110576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The gastrointestinal (GI) tract is a continuous channel through the body that consists of the esophagus, the stomach, the small intestine, the large intestine, and the rectum. Its primary functions are to move the intake of food for digestion before storing and ultimately expulsion of feces. The mechanical behavior of GI tissues thus plays a crucial role for GI function in health and disease. The mechanical properties are characterized by a biomechanical constitutive model, which is a mathematical representation of the relation between load and deformation in a tissue. Hence, validated biomechanical constitutive models are essential to characterize and simulate the mechanical behavior of the GI tract. Here, a systematic review of these constitutive models is provided. This review is limited to studies where a model of the strain energy function is proposed to characterize the stress-strain relation of a GI tissue. Several needs are identified for more advanced modeling including: 1) Microstructural models that provide actual structure-function relations; 2) Validation of coupled electro-mechanical models accounting for active muscle contractions; 3) Human data to develop and validate models. The findings from this review provide guidelines for using existing constitutive models as well as perspective and directions for future studies.
Collapse
Affiliation(s)
- Bhavesh Patel
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Alessio Gizzi
- Department of Engineering, Campus Bio-Medico University of Rome, Via A. del Portillo 21, 00128 Rome, IT
| | - Javad Hashemi
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Yousif Awakeem
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Hans Gregersen
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Ghassan Kassab
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
- Corresponding author , Tel: 001-858-249-7400, Fax: 001-858-249-7419, (Ghassan Kassab)
| |
Collapse
|
6
|
Zhao Y, Feng B, Pierce DM. Predicting the micromechanics of embedded nerve fibers using a novel three-layered model of mouse distal colon and rectum. J Mech Behav Biomed Mater 2022; 127:105083. [PMID: 35093713 PMCID: PMC8916824 DOI: 10.1016/j.jmbbm.2022.105083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 12/21/2021] [Accepted: 01/08/2022] [Indexed: 11/20/2022]
Abstract
Mechanotransduction plays a central role in evoking pain from the distal colon and rectum (colorectum) where embedded sensory nerve endings convert micromechanical stresses and strains into neural action potentials. The colorectum displays strong through-thickness and longitudinal heterogeneity with collagen concentrated in the submucosa thus indicating the significant load-bearing role of this layer. The density of sensory nerve endings is also significantly the greatest in the submucosa, suggesting a nociceptive function. Thus biomechanical heterogeneity in the colorectum influences the micromechanical stresses and strains surrounding afferent endings embedded within different layers of the colorectum which is critical for the mechanotransduction of various mechanical stimuli. In this study we aimed to: (1) calibrate and validate a three-layered computational model of the colorectum; (2) predict intra-tissue distributions of stresses and strains during mechanical stimulation of the colorectum ex vivo (i.e. circumferential stretching, punctuate probing, and mucosal shearing); and (3) establish a methodology to calculate local micromechanical stresses and strains surrounding afferent nerve endings embedded in the colorectum. We established three-layered FE models that include mucosa, submucosa, and muscular layers, and incorporated residual stretches, to calculate intra-tissue stresses and strains when the colorectum undergoes the mechanical stimuli used to characterize afferent neural encoding ex vivo. Finally, we established a methodology for detailed calculations of the local micromechanical stresses and strains surrounding afferent endings embedded in the colorectum and demonstrated this with a representative example. Our novel methodologies will bridge the existing neurophysiological and biomechanical evidence from experiments to advance our mechanistic understanding of colorectal mechanotransduction.
Collapse
Affiliation(s)
- Yunmei Zhao
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT, USA; Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Bin Feng
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - David M Pierce
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT, USA; Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA.
| |
Collapse
|
7
|
Coupled experimental and computational approach to stomach biomechanics: Towards a validated characterization of gastric tissues mechanical properties. J Mech Behav Biomed Mater 2021; 125:104914. [PMID: 34715641 DOI: 10.1016/j.jmbbm.2021.104914] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 10/06/2021] [Accepted: 10/17/2021] [Indexed: 12/31/2022]
Abstract
Gastric diseases are one of the most relevant healthcare problems worldwide. Interventions and therapies definition/design mainly derive from biomedical and clinical expertise. Computational biomechanics, with particular regard to the finite element method, provides hard-to-measure quantities during in-vivo tests, such as strain and stress distribution, leading to a more comprehensive and promising approach to improve the effectiveness of many different clinical activities. However, reliable finite element models of biological organs require appropriate constitutive formulations of building tissues, whose parameters identification needs an experimental campaign consisting in different tests on human tissues and organs. The aim of the reported here research activities was the identification of mechanical properties of human gastric tissues. Human gastric specimens were tested at tissue, sub-structural and structural levels, by tensile, membrane indentation and inflation tests, respectively. On the other hand, animal experimentations on tissue layers from literature pointed out the mechanical response at sub-tissue level during tensile loading conditions. In detail, the analysis of experimental results at sub-tissue and tissue levels led to a fibre-reinforced visco-hyperelastic constitutive formulation and to the identification of gastric layers mechanical behaviour. Results from experimentations on human samples were coupled with data derived from animal models. Data from sub-structural and structural experimentations were exploited to upgrade and validate the constitutive formulations and parameters. The developed investigations led to a reliable constitutive framework of human gastric tissues that both describe stomach mechanical functionality and allow computational investigations. Indeed, the comparisons among average computational data and experimental medians provided the following RMSEs (Root Mean Square Errors): 0.89 N, 0.15 N for corpus and fundus during membrane indentation test, respectively, and 0.44 kPa during inflation test. Accounting for the magnitude of experimental and computational data, the RMSEs can be considered low and acceptable because they concerned biological samples. In fact, biological tissues and structures are affected by a high inherent inter-samples' variability, which is detectable in both the geometrical configuration and the mechanical behaviour. The specific values of the here reported RMSEs ensured the reliability of the achieved parameters and the quality of the overall developed procedure. Reliable computational models of the gastric district could become efficient clinical tools to find out the main crucial aspects of bariatric procedures, such as the mechanical stimulation of gastric mechano-receptors. Moreover, the methods of computational biomechanics will permit to run the preliminary tests of new and innovative bariatric procedures, on one hand, predicting the successful rate and the effectiveness, and, on other hand, reducing the use of animal testing.
Collapse
|
8
|
Nagaraja S, Leichsenring K, Ambati M, De Lorenzis L, Böl M. On a phase-field approach to model fracture of small intestine walls. Acta Biomater 2021; 130:317-331. [PMID: 34119714 DOI: 10.1016/j.actbio.2021.06.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 05/31/2021] [Accepted: 06/02/2021] [Indexed: 12/15/2022]
Abstract
We address anisotropic elasticity and fracture in small intestine walls (SIWs) with both experimental and computational methods. Uniaxial tension experiments are performed on porcine SIW samples with varying alignments and quantify their nonlinear elastic anisotropic behavior. Fracture experiments on notched SIW strips reveal a high sensitivity of the crack propagation direction and the failure stress on the tissue orientation. From a modeling point of view, the observed anisotropic elastic response is studied with a continuum mechanical model stemming from a strain energy density with a neo-Hookean component and an anisotropic component with four families of fibers. Fracture is addressed with the phase-field approach, featuring two-fold anisotropy in the fracture toughness. Elastic and fracture model parameters are calibrated based on the experimental data, using the maximum and minimum limits of the experimental stress-stretch data set. A very good agreement between experimental data and computational results is obtained, the role of anisotropy being effectively captured by the proposed model in both the elastic and the fracture behavior. STATEMENT OF SIGNIFICANCE: This article reports a comprehensive experimental data set on the mechanical failure behavior of small intestinal tissue, and presents the corresponding protocols for preparing and testing the samples. On the one hand, the results of this study contribute to the understanding of small intestine mechanics and thus to understanding of load transfer mechanisms inside the tissue. On the other hand, these results are used as input for a phase-field modelling approach, presented in this article. The presented model can reproduce the mechanical failure behavior of the small intestine in an excellent way and is thus a promising tool for the future mechanical description of diseased small intestinal tissue.
Collapse
|
9
|
Rivera E, Canales C, Pacheco M, García-Herrera C, Macías D, Celentano DJ, Herrera EA. Biomechanical characterization of the passive response of the thoracic aorta in chronic hypoxic newborn lambs using an evolutionary strategy. Sci Rep 2021; 11:13875. [PMID: 34230509 PMCID: PMC8260639 DOI: 10.1038/s41598-021-93267-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 06/22/2021] [Indexed: 11/22/2022] Open
Abstract
The present study involves experiments and modelling aimed at characterizing the passive structural mechanical behavior of the chronic hypoxic lamb thoracic aorta, whose gestation, birth and postnatal period were carried at high altitude (3600 masl). To this end, the mechanical response was studied via tensile and pressurization tests. The tensile and pressurization tests measurements were used simultaneously to calibrate the material parameters of the Gasser-Holzapfel-Ogden (GHO) hyperelasctic anisotropic constitutive model through an analytical-numerical optimization procedure solved with an evolutionary strategy that guarantees a stable response of the model. The model and procedure of calibration adequately adjust to the material behavior in a wide deformation range with an appropriate physical description. The results of this study predict the mechanical response of the lamb thoracic aorta under generalized loading states like those that can occur in physiological conditions and/or in systemic arterial hypertension. Finally, the novel use of the evolutionary strategy, together with the set of experiments and tools used in this study, provide a robust alternative to validate biomechanical characterizations.
Collapse
Affiliation(s)
- Eugenio Rivera
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile.
| | - Claudio Canales
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile
| | - Matías Pacheco
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile
| | - Claudio García-Herrera
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile
| | - Demetrio Macías
- ICD, P2MN, L2n, Université de Technologie de Troyes, ERL 7004, CNRS, Troyes, France
| | - Diego J Celentano
- Departamento de Ingeniería Mecánica y Metalúrgica, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Santiago de Chile, Chile
| | - Emilio A Herrera
- Laboratorio de Función y Reactividad Vascular, Programa de Fisiopatología, ICBM, Universidad de Chile, Av. Salvador 486, Santiago de Chile, Chile
| |
Collapse
|
10
|
Khan AF, MacDonald MK, Streutker C, Rowsell C, Drake J, Grantcharov T. Tissue stress from laparoscopic grasper use and bowel injury in humans: establishing intraoperative force boundaries. BMJ SURGERY, INTERVENTIONS, & HEALTH TECHNOLOGIES 2021; 3:e000084. [PMID: 35047803 PMCID: PMC8749288 DOI: 10.1136/bmjsit-2021-000084] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 06/01/2021] [Indexed: 11/05/2022] Open
Abstract
Objectives We aim to determine what threshold of compressive stress small bowel and colon tissues display evidence of significant tissue trauma during laparoscopic surgery. Design This study included 10 small bowel and 10 colon samples from patients undergoing routine gastrointestinal surgery. Each sample was compressed with pressures ranging from 100 kPa to 600 kPa. Two pathologists who were blinded to all study conditions, performed a histological analysis of the tissues. Experimentation: November 2018–February 2019. Analysis: March 2019–May 2020. Setting An inner-city trauma and ambulatory hospital with a 40-bed inpatient general surgery unit with a diverse patient population. Participants Patients were eligible if their surgery procured healthy tissue margins for experimentation (a convenience sample). 26 patient samples were procured; 6 samples were unusable. 10 colon and 10 small bowel samples were tested for a total of 120 experimental cases. No patients withdrew their consent. Interventions A novel device was created to induce compressive “grasps” to simulate those of a laparoscopic grasper. Experimentation was performed ex-vivo, in-vitro. Grasp conditions of 0–600 kPa for a duration of 10 s were used. Results Small bowel (10), M:F was 7:3, average age was 54.3 years. Colon (10), M:F was 1:1, average age was 65.2 years. All 20 patients experienced a significant difference (p<0.05) in serosal thickness post-compression at both 500 and 600 kPa for both tissue types. A logistic regression analysis with a sensitivity of 100% and a specificity of 84.6% on a test set of data predicts a safety threshold of 329–330 kPa. Conclusions A threshold was discovered that corresponded to both significant serosal thickness change and a positive histological trauma score rating. This “force limit” could be used in novel sensorized laparoscopic tools to avoid intraoperative tissue injury.
Collapse
Affiliation(s)
| | | | - Catherine Streutker
- Laboratory Medicine and Pathobiology, St Michael's Hospital, Toronto, Ontario, Canada
| | - Corwyn Rowsell
- Laboratory Medicine and Pathobiology, St Michael's Hospital, Toronto, Ontario, Canada
| | - James Drake
- CIGITI Lab, University of Toronto, Toronto, Ontario, Canada
| | | |
Collapse
|
11
|
Fontanella CG, Arduino A, Toniolo I, Zampieri C, Bortolan L, Carniel EL. Computational methods for the investigation of ski boots ergonomics. SPORTS ENGINEERING 2021. [DOI: 10.1007/s12283-021-00352-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
AbstractSki boots are known to cause vasoconstriction in the wearer’s lower limbs and, thus, cause a “cold leg” phenomenon. To address this problem, this work provides a computational framework for analysing interactions between the ski boot and the lower limb. The geometry of the lower limb was derived from magnetic resonance imaging and computed tomography techniques and anthropometric data. The geometry of the ski boot shell was obtained by means of three-dimensional computer aided design models from a manufacturer. Concerning the ski boot liner, laser scanning techniques were implemented to capture the geometry of each layer. The mechanical models of the ski boot and the lower limb were identified and validated by means of coupled experimental investigations and computational analyses. The computational models were exploited to simulate the buckling process and to investigate interaction phenomena between the boot and the lower limb. Similarly, experimental activities were performed to further analyse the buckling phenomena. The obtained computational and experimental results were compared regarding both interaction pressure and displacements between the buckle and the corresponding buckle hooks. These comparisons provided reasonable agreement (mean value of discrepancy between the model and mean experimental results in the tibial region: 20%), underlining the model’s capability to correctly interpret results from experimental measurements. Results identified the critical areas of the leg, such as the tibial region, the calcaneal region of the foot and the anterior sole, which may suffer the most due to the hydrostatic pressure and compressive strain exerted on them. The results highlight that computational methods allow investigation of the interaction phenomena between the lower leg and ski boot, potentially providing an effective framework for a more comfortable and ergonomic design of ski boots.
Collapse
|
12
|
Steger J, Patzke I, Berlet M, Ficht S, Eblenkamp M, Mela P, Wilhelm D. Design of a force-measuring setup for colorectal compression anastomosis and first ex-vivo results. Int J Comput Assist Radiol Surg 2021; 16:1335-1345. [PMID: 33891254 PMCID: PMC8295116 DOI: 10.1007/s11548-021-02371-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 04/06/2021] [Indexed: 12/03/2022]
Abstract
Purpose The introduction of novel endoscopic instruments is essential to reduce trauma in visceral surgery. However, endoscopic device development is hampered by challenges in respecting the dimensional restrictions, due to the narrow access route, and by achieving adequate force transmission. As the overall goal of our research is the development of a patient adaptable, endoscopic anastomosis manipulator, biomechanical and size-related characterization of gastrointestinal organs are needed to determine technical requirements and thresholds to define functional design and load-compatible dimensioning of devices. Methods We built an experimental setup to measure colon tissue compression piercing forces. We tested 54 parameter sets, including variations of three tissue fixation configurations, three piercing body configurations (four, eight, twelve spikes) and insertion trajectories of constant velocities (5 mms−1, 10 mms−1,15 mms−1) and constant accelerations (5 mms−2, 10 mms−2, 15 mms−2) each in 5 samples. Furthermore, anatomical parameters (lumen diameter, tissue thickness) were recorded. Results There was no statistically significant difference in insertion forces neither between the trajectory groups, nor for variation of tissue fixation configurations. However, we observed a statistically significant increase in insertion forces for increasing number of spikes. The maximum mean peak forces for four, eight and twelve spikes were 6.4 ± 1.5 N, 13.6 ± 1.4 N and 21.7 ± 5.8 N, respectively. The 5th percentile of specimen lumen diameters and pierced tissue thickness were 24.1 mm and 2.8 mm, and the 95th percentiles 40.1 mm and 4.8 mm, respectively. Conclusion The setup enabled reliable biomechanical characterization of colon material, on the base of which design specifications for an endoscopic anastomosis device were derived. The axial implant closure unit must enable axial force transmission of at least 28 N (22 ± 6 N). Implant and applicator diameters must cover a range between 24 and 40 mm, and the implant gap, compressing anastomosed tissue, between 2 and 5 mm.
Collapse
Affiliation(s)
- Jana Steger
- Research Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany. .,Chair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany.
| | - Isabella Patzke
- Research Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany.,Chair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Maximilian Berlet
- Research Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany.,Clinic and Policlinic for Surgery, Faculty of Medicine, Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany
| | - Stefanie Ficht
- Chair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Markus Eblenkamp
- Chair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Petra Mela
- Chair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Dirk Wilhelm
- Research Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany.,Clinic and Policlinic for Surgery, Faculty of Medicine, Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany
| |
Collapse
|
13
|
Oetzmann von Sochaczewski C, Tagkalos E, Lindner A, Lang H, Heimann A, Muensterer OJ. A Continuous Suture Anastomosis Outperforms a Simple Interrupted Suture Anastomosis in Esophageal Elongation. Eur J Pediatr Surg 2021; 31:177-181. [PMID: 32422674 DOI: 10.1055/s-0040-1710025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
INTRODUCTION Long-gap esophageal atresia represents a distinct entity among the esophageal atresia spectrum. In many patients, achieving a reasonable anastomosis depends on some millimeters of tissue. We aimed to determine what effect the suturing technique would have on esophageal ex vivo elongation as it may determine the strength of a primary anastomosis. MATERIALS AND METHODS In an analysis of porcine esophagi from animals for slaughter (100-120 days old with a weight of 100-120 kg), we determined esophageal length gain of simple continuous and simple interrupted suture anastomoses subjected to linear traction until linear breaking strength was reached. Statistical power of 80% was ensured based on an a priori power analysis using five specimens per group in a separate exploratory experiment. RESULTS The simple continuous suture anastomosis in 15 porcine esophagi ( = 4.47 cm, 95% confidence interval: 4.08-4.74 cm) outperformed the simple interrupted suture anastomosis in another 15 esophagi ( = 3.03 cm, 95% confidence interval: 2.59-3.43 cm) in length gain (Δ = 1.44 cm, 95% confidence interval: 0.87-2.01 cm, p < 0.0001). CONCLUSION Simple continuous anastomoses achieved higher length gain compared with simple interrupted suture anastomoses. This effect warrants an experimental assessment in vivo to assess its potential merits for clinical applicability.
Collapse
Affiliation(s)
| | - Evangelos Tagkalos
- Department of General, Visceral and Transplant Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Andreas Lindner
- Department of Pediatric Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Hauke Lang
- Department of General, Visceral and Transplant Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Axel Heimann
- Institute for Neurosurgical Pathophysiology, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Oliver J Muensterer
- Department of Pediatric Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| |
Collapse
|
14
|
Zhao Y, Siri S, Feng B, Pierce DM. Computational Modeling of Mouse Colorectum Capturing Longitudinal and Through-thickness Biomechanical Heterogeneity. J Mech Behav Biomed Mater 2021; 113:104127. [PMID: 33125950 PMCID: PMC8053306 DOI: 10.1016/j.jmbbm.2020.104127] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Revised: 09/03/2020] [Accepted: 10/01/2020] [Indexed: 12/19/2022]
Abstract
Mechanotransduction, the encoding of local mechanical stresses and strains at sensory endings into neural action potentials at the viscera, plays a critical role in evoking visceral pain, e.g., in the distal colon and rectum (colorectum). The wall of the colorectum is structurally heterogeneous, including two major composites: the inner consists of muscular and submucosal layers, and the outer consists of circular muscular, intermuscular, longitudinal muscular, and serosal layers. In fact the colorectum presents biomechanical heterogenity across both the longitudinal and through-thickness directions thus highlighting the differential roles of sensory nerve endings within different regions of the colorectum in visceral mechanotransduction. We determined constitutive models and model parameters for individual layers of the colorectum from three longitudinal locations (colonic, intermediate, and distal) using nonlinear optimization to fit our experimental results from biaxial extension tests on layer-separated colorectal tissues (mouse model, 7×7 mm2, Siri et al., Am. J. Physiol. Gastrointest. Liver Physiol. 316, G473-G481 and 317, G349-G358), and quantified the thicknesses of the layers. In this study we also quantified the residual stretches stemming from separating colorectal specimens into inner and outer composites and we completed new pressure-diameter mechanical testing to provide an additional validation case. We implemented the constitutive equations and created two-layered, 3-D finite element models using FEBio (University of Utah), and incorporated the residual stretches. We validated the modeling framework by comparing FE-predicted results for both biaxial extension testing of bulk specimens of colorectum and pressure-diameter testing of bulk segments against corresponding experimental results independent of those used in our model fitting. We present the first theoretical framework to simulate the biomechanics of distal colorectum, including both longitudinal and through-thickness heterogeneity, based on constitutive modeling of biaxial extension tests of colon tissues from mice. Our constitutive models and modeling framework facilitate analyses of both fundamental questions (e.g., the impact of organ/tissue biomechanics on mechanotransduction of the sensory nerve endings, structure-function relationships, and growth and remodeling in health and disease) and specific applications (e.g., device design, minimally invasive surgery, and biomedical research).
Collapse
Affiliation(s)
- Y Zhao
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT, USA; Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - S Siri
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - B Feng
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - D M Pierce
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT, USA; Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA.
| |
Collapse
|
15
|
Toniolo I, Fontanella CG, Foletto M, Carniel EL. Biomechanical Investigation of the Stomach Following Different Bariatric Surgery Approaches. Bioengineering (Basel) 2020; 7:bioengineering7040159. [PMID: 33317122 PMCID: PMC7764040 DOI: 10.3390/bioengineering7040159] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 12/02/2020] [Accepted: 12/07/2020] [Indexed: 12/15/2022] Open
Abstract
Background: The stomach is a hollow organ of the gastrointestinal tract, on which bariatric surgery (BS) is performed for the treatment of obesity. Even though BS is the most effective treatment for severe obesity, drawbacks and complications are still present because the intervention design is largely based on the surgeon’s expertise and intraoperative decisions. Bioengineering methods can be exploited to develop computational tools for more rational presurgical design and planning of the intervention. Methods: A computational mechanical model of the stomach was developed, considering the actual complexity of the biological structure, as the nonhomogeneous and multilayered configuration of the gastric wall. Mechanical behavior was characterized by means of an anisotropic visco-hyperelastic constitutive formulation of fiber-reinforced conformation, nonlinear elastic response, and time-dependent behavior, which assume the typical features of gastric wall mechanics. Model applications allowed for an analysis of the influence of BS techniques on stomach mechanical functionality through different computational analyses. Results: Computational results showed that laparoscopic sleeve gastrectomy and endoscopic sleeve gastroplasty drastically alter stomach capacity and stiffness, while laparoscopic adjustable gastric banding modestly affects stomach stiffness and capacity. Moreover, the mean elongation strain values, which are correlated to the mechanical stimulation of gastric receptors, were elevated in laparoscopic adjustable gastric banding compared to other procedures. Conclusions: The investigation of stomach mechanical response through computational models provides information on different topics such as stomach capacity and stiffness and the mechanical stimulation of gastric receptors, which interact with the brain to control satiety. These data can provide reliable support to surgeons in the presurgical decision-making process.
Collapse
Affiliation(s)
- Ilaria Toniolo
- Department of Industrial Engineering, University of Padova, Via Venezia 1, 35131 Padova, Italy; (I.T.); (E.L.C.)
| | - Chiara Giulia Fontanella
- Department of Industrial Engineering, University of Padova, Via Venezia 1, 35131 Padova, Italy; (I.T.); (E.L.C.)
- Centre for Mechanics of Biological Materials, University of Padova, Via F. Marzolo 9, 35131 Padova, Italy;
- Correspondence: ; Tel.: +39-049-8276754
| | - Mirto Foletto
- Centre for Mechanics of Biological Materials, University of Padova, Via F. Marzolo 9, 35131 Padova, Italy;
- IFSO Bariatric Center of Excellence, Padova University Hospital, Via Ospedale Civile, 35121 Padova, Italy
| | - Emanuele Luigi Carniel
- Department of Industrial Engineering, University of Padova, Via Venezia 1, 35131 Padova, Italy; (I.T.); (E.L.C.)
- Centre for Mechanics of Biological Materials, University of Padova, Via F. Marzolo 9, 35131 Padova, Italy;
| |
Collapse
|
16
|
Zhao Y, Siri S, Feng B, Pierce DM. The Macro- and Micro-Mechanics of the Colon and Rectum II: Theoretical and Computational Methods. Bioengineering (Basel) 2020; 7:bioengineering7040152. [PMID: 33255522 PMCID: PMC7712199 DOI: 10.3390/bioengineering7040152] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Revised: 11/02/2020] [Accepted: 11/23/2020] [Indexed: 12/19/2022] Open
Abstract
Abnormal colorectal biomechanics and mechanotransduction associate with an array of gastrointestinal diseases, including inflammatory bowel disease, irritable bowel syndrome, diverticula disease, anorectal disorders, ileus, and chronic constipation. Visceral pain, principally evoked from mechanical distension, has a unique biomechanical component that plays a critical role in mechanotransduction, the process of encoding mechanical stimuli to the colorectum by sensory afferents. To fully understand the underlying mechanisms of visceral mechanical neural encoding demands focused attention on the macro- and micro-mechanics of colon tissue. Motivated by biomechanical experiments on the colon and rectum, increasing efforts focus on developing constitutive frameworks to interpret and predict the anisotropic and nonlinear biomechanical behaviors of the multilayered colorectum. We will review the current literature on computational modeling of the colon and rectum as well as the mechanical neural encoding by stretch sensitive afferent endings, and then highlight our recent advances in these areas. Current models provide insight into organ- and tissue-level biomechanics as well as the stretch-sensitive afferent endings of colorectal tissues yet an important challenge in modeling theory remains. The research community has not connected the biomechanical models to those of mechanosensitive nerve endings to create a cohesive multiscale framework for predicting mechanotransduction from organ-level biomechanics.
Collapse
Affiliation(s)
- Yunmei Zhao
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (Y.Z.); (S.S.); (B.F.)
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Saeed Siri
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (Y.Z.); (S.S.); (B.F.)
| | - Bin Feng
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (Y.Z.); (S.S.); (B.F.)
| | - David M. Pierce
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (Y.Z.); (S.S.); (B.F.)
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
- Correspondence:
| |
Collapse
|
17
|
Biomechanical Force Prediction for Lengthening of Small Intestine during Distraction Enterogenesis. Bioengineering (Basel) 2020; 7:bioengineering7040140. [PMID: 33171760 PMCID: PMC7711478 DOI: 10.3390/bioengineering7040140] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 10/04/2020] [Accepted: 10/28/2020] [Indexed: 11/16/2022] Open
Abstract
Distraction enterogenesis has been extensively studied as a potential treatment for short bowel syndrome, which is the most common form of intestinal failure. Different strategies including parenteral nutrition and surgical lengthening to manage patients with short bowel syndrome are associated with high complication rates. More recently, self-expanding springs have been used to lengthen the small intestine using an intraluminal axial mechanical force, where this biomechanical force stimulates the growth and elongation of the small intestine. Differences in physical characteristics of patients with short bowel syndrome would require a different mechanical force—this is crucial in order to achieve an efficient and safe lengthening outcome. In this study, we aimed to predict the required mechanical force for each potential intestinal size. Based on our previous experimental observations and computational findings, we integrated our experimental measurements of patient biometrics along with mechanical characterization of the soft tissue into our numerical simulations to develop a series of computational models. These computational models can predict the required mechanical force for any potential patient where this can be advantageous in predicting an individual’s tissue response to spring-mediated distraction enterogenesis and can be used toward a safe delivery of the mechanical force.
Collapse
|
18
|
The Macro- and Micro-Mechanics of the Colon and Rectum I: Experimental Evidence. Bioengineering (Basel) 2020; 7:bioengineering7040130. [PMID: 33086503 PMCID: PMC7712174 DOI: 10.3390/bioengineering7040130] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 10/12/2020] [Accepted: 10/15/2020] [Indexed: 12/14/2022] Open
Abstract
Many lower gastrointestinal diseases are associated with altered mechanical movement and deformation of the large intestine, i.e., the colon and rectum. The leading reason for patients' visits to gastrointestinal clinics is visceral pain, which is reliably evoked by mechanical distension rather than non-mechanical stimuli such as inflammation or heating. The macroscopic biomechanics of the large intestine were characterized by mechanical tests and the microscopic by imaging the load-bearing constituents, i.e., intestinal collagen and muscle fibers. Regions with high mechanical stresses in the large intestine (submucosa and muscularis propria) coincide with locations of submucosal and myenteric neural plexuses, indicating a functional interaction between intestinal structural biomechanics and enteric neurons. In this review, we systematically summarized experimental evidence on the macro- and micro-scale biomechanics of the colon and rectum in both health and disease. We reviewed the heterogeneous mechanical properties of the colon and rectum and surveyed the imaging methods applied to characterize collagen fibers in the intestinal wall. We also discussed the presence of extrinsic and intrinsic neural tissues within different layers of the colon and rectum. This review provides a foundation for further advancements in intestinal biomechanics by synergistically studying the interplay between tissue biomechanics and enteric neurons.
Collapse
|
19
|
GRAMIGNA VERA, FRAGOMENI GIONATA, FONTANELLA CHIARAGIULIA, STEFANINI CESARE, CARNIEL EMANUELELUIGI. A COUPLED EXPERIMENTAL AND NUMERICAL APPROACH TO CHARACTERIZE THE ANISOTROPIC MECHANICAL BEHAVIOR OF AORTIC TISSUES. J MECH MED BIOL 2020. [DOI: 10.1142/s021951942050027x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Nowadays, the investigation of aortic wall biomechanics is a fundamental tool in clinical research and vascular prosthesis design. This study aims at analyzing the biomechanical behavior of aortic tissues using a coupled experimental and computational approach. Considering the typical fiber-reinforced configuration of aortic tissues, uni-axial tensile tests along six different loading directions were performed on specimens from pig aorta. Starting from the obtained experimental data, a suitable constitutive framework was defined and a methodology for the identification of the constitutive parameters was developed using the inverse analysis of mechanical tests. Transversal stretch versus loading stretch and nominal stress versus loading stretch curves were evaluated, showing the anisotropic and nonlinear mechanical behavior determined by tissue conformation with fibers distributed along preferential directions. In detail, experimental data showed different mechanical responses between longitudinal and circumferential directions, with a greater tissue stiffness along the longitudinal one. The reliability of the developed constitutive framework was evaluated by the comparison between experimental data and model results. The mentioned analysis can be considered as a useful tool for the development of reliable computational models, which allow a better understanding of the pathophysiology of cardiovascular diseases and can be applied for a proper planning of surgical procedures.
Collapse
Affiliation(s)
- VERA GRAMIGNA
- Neuroscience Research Center, Magna Graecia University, Viale Europa, 88100 Catanzaro, Italy
| | - GIONATA FRAGOMENI
- Medical and Surgical Sciences, Magna Graecia University, Viale Europa, 88100 Catanzaro, Italy
| | - CHIARA GIULIA FONTANELLA
- Department of Industrial Engineering, Centre for Mechanics of Biological Materials, University of Padova, Via Venezia 1, Padova I-35131, Italy
| | - CESARE STEFANINI
- The BioRobotics Institute, Scuola Superiore Sant’Anna, Viale Rinaldo Piaggio 34, Pontedera (Pisa) I-56025, Italy
- Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, UAE
| | - EMANUELE LUIGI CARNIEL
- Department of Industrial Engineering, Centre for Mechanics of Biological Materials, University of Padova, Via Venezia 1, Padova I-35131, Italy
| |
Collapse
|
20
|
Natali AN, Fontanella CG, Todros S, Pavan PG, Carmignato S, Zanini F, Carniel EL. Conformation and mechanics of the polymeric cuff of artificial urinary sphincter. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2020; 17:3894-3908. [PMID: 32987559 DOI: 10.3934/mbe.2020216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The surgical treatment of urinary incontinence is often performed by adopting an Artificial Urinary Sphincter (AUS). AUS cuff represents a fundamental component of the device, providing the mechanical action addressed to urethral occlusion, which can be investigated by computational approach. In this work, AUS cuff is studied with reference to both materials and structure, to develop a finite element model. Materials behavior is investigated using physicochemical and mechanical characterization, leading to the formulation of a constitutive model. Materials analysis shows that AUS cuff is composed by a silicone blister joined with a PET fiber-reinforced layer. A nonlinear mechanical behavior is found, with a higher stiffness in the outer layer due to fiber-reinforcement. The cuff conformation is acquired by Computer Tomography (CT) both in deflated and inflated conditions, for an accurate definition of the geometrical characteristics. Based on these data, the numerical model of AUS cuff is defined. CT images of the inflated cuff are compared with results of numerical analysis of the inflation process, for model validation. A relative error below 2.5% was found. This study is the first step for the comprehension of AUS mechanical behavior and allows the development of computational tools for the analysis of lumen occlusion process. The proposed approach could be adapted to further fluid-filled cuffs of artificial sphincters.
Collapse
Affiliation(s)
- Arturo Nicola Natali
- Department of Industrial Engineering, University of Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Italy
| | - Chiara Giulia Fontanella
- Department of Industrial Engineering, University of Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Italy
| | - Silvia Todros
- Department of Industrial Engineering, University of Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Italy
| | - Piero G Pavan
- Department of Industrial Engineering, University of Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Italy
| | - Simone Carmignato
- Centre for Mechanics of Biological Materials, University of Padova, Italy
- Department of Management and Engineering, University of Padova, Italy
| | - Filippo Zanini
- Department of Management and Engineering, University of Padova, Italy
| | - Emanuele Luigi Carniel
- Department of Industrial Engineering, University of Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Italy
| |
Collapse
|
21
|
Computational analysis of mechanical stress in colonic diverticulosis. Sci Rep 2020; 10:6014. [PMID: 32265489 PMCID: PMC7138845 DOI: 10.1038/s41598-020-63049-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 03/18/2020] [Indexed: 12/15/2022] Open
Abstract
Diverticulosis results from the development of pouch-like structures, called diverticula, over the colon. The etiology of the disease is poorly understood resulting in a lack of effective treatment approaches. It is well known that mechanical stress plays a major role in tissue remodeling, yet its role in diverticulosis has not been studied. Here, we used computational mechanics to investigate changes in stress distribution engendered over the colon tissue by the presence of a pouch-like structure. The objectives of the study were twofold: (1) observe how stress distribution changes around a single pouch and (2) evaluate how stress elevation correlates with the size of the pouch. Results showed that high stresses are concentrated around the neck of a pouch, and their values and propagation increase with the size of the pouch neck rather than the pouch surface area. These findings suggest that stress distribution may change in diverticulosis and a vicious cycle may occur where pouch size increases due to stress elevation, which in turn elevates stress further and so on. Significant luminal pressure reduction would be necessary to maintain stress at normal level according to our results and therapeutic approaches aimed directly at reducing stress should rather be sought after.
Collapse
|
22
|
Panda SK, Buist ML. A viscoelastic framework for inflation testing of gastrointestinal tissue. J Mech Behav Biomed Mater 2020; 103:103569. [DOI: 10.1016/j.jmbbm.2019.103569] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 11/26/2019] [Accepted: 11/29/2019] [Indexed: 12/01/2022]
|
23
|
Puértolas S, Peña E, Herrera A, Ibarz E, Gracia L. A comparative study of hyperelastic constitutive models for colonic tissue fitted to multiaxial experimental testing. J Mech Behav Biomed Mater 2020; 102:103507. [DOI: 10.1016/j.jmbbm.2019.103507] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 10/04/2019] [Accepted: 10/23/2019] [Indexed: 01/16/2023]
|
24
|
Hosseini HS, Taylor JS, Wood LS, Dunn JC. Biomechanics of small intestine during distraction enterogenesis with an intraluminal spring. J Mech Behav Biomed Mater 2020; 101:103413. [DOI: 10.1016/j.jmbbm.2019.103413] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2019] [Revised: 06/13/2019] [Accepted: 08/31/2019] [Indexed: 12/25/2022]
|
25
|
Feng B, Guo T. Visceral pain from colon and rectum: the mechanotransduction and biomechanics. J Neural Transm (Vienna) 2019; 127:415-429. [PMID: 31598778 DOI: 10.1007/s00702-019-02088-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Accepted: 09/28/2019] [Indexed: 12/14/2022]
Abstract
Visceral pain is the cardinal symptom of functional gastrointestinal (GI) disorders such as the irritable bowel syndrome (IBS) and the leading cause of patients' visit to gastroenterologists. IBS-related visceral pain usually arises from the distal colon and rectum (colorectum), an intraluminal environment that differs greatly from environment outside the body in chemical, biological, thermal, and mechanical conditions. Accordingly, visceral pain is different from cutaneous pain in several key psychophysical characteristics, which likely underlies the unsatisfactory management of visceral pain by drugs developed for other types of pain. Colorectal visceral pain is usually elicited from mechanical distension/stretch, rather than from heating, cutting, pinching, or piercing that usually evoke pain from the skin. Thus, mechanotransduction, i.e., the encoding of colorectal mechanical stimuli by sensory afferents, is crucial to the underlying mechanisms of GI-related visceral pain. This review will focus on colorectal mechanotransduction, the process of converting colorectal mechanical stimuli into trains of action potentials by the sensory afferents to inform the central nervous system (CNS). We will summarize neurophysiological studies on afferent encoding of colorectal mechanical stimuli, highlight recent advances in our understanding of colorectal biomechanics that plays critical roles in mechanotransduction, and review studies on mechano-sensitive ion channels in colorectal afferents. This review calls for focused attention on targeting colorectal mechanotransduction as a new strategy for managing visceral pain, which can also have an added benefit of limited CNS side effects, because mechanotransduction arises from peripheral organs.
Collapse
Affiliation(s)
- Bin Feng
- Department of Biomedical Engineering, University of Connecticut, 260 Glenbrook Road, Unit 3247, Storrs, CT, 06269-3247, USA.
| | - Tiantian Guo
- Department of Biomedical Engineering, University of Connecticut, 260 Glenbrook Road, Unit 3247, Storrs, CT, 06269-3247, USA
| |
Collapse
|
26
|
Investigating the effects of various suturing parameters on the leakage from the intestinal anastomosis site: finite element analyses. Biocybern Biomed Eng 2019. [DOI: 10.1016/j.bbe.2019.08.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
27
|
Massalou D, Masson C, Afquir S, Baqué P, Arnoux PJ, Bège T. Influence of gender, age, shelf-life, and conservation method on the biomechanical behavior of colon tissue under dynamic solicitation. Clin Biomech (Bristol, Avon) 2019; 65:34-40. [PMID: 30954683 DOI: 10.1016/j.clinbiomech.2019.03.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Revised: 03/19/2019] [Accepted: 03/27/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Data from biomechanical tissue sample studies of the human digestive tract are highly variable. The aim of this study was to investigate 4 factors which could modify the mechanical response of human colonic specimens placed under dynamic solicitation until tissue rupture: gender, age, shelf-life and conservation method. METHODS We performed uniaxial dynamic tests of human colonic specimens. Specimens were taken according to three different protocols: refrigerated cadavers without embalming, embalmed cadavers and fresh colonic tissue. A total of 143 specimens were subjected to tensile tests, at a speed of 1 m s-1. FINDINGS Young's modulus of the different conservation protocols are as follows: embalmed, 3.08 ± 1.99; fresh, 2.97 ± 2.59; and refrigerated 3.17 ± 2.05. The type of conservation does not modify the stiffness of the tissue (p = 0.26) but does modify the stress necessary for rupture (p < 0.001) and the strain required to obtain lesions of the outer layer and the inner layer (p < 0.001 and p < 0.05, respectively). Gender is also a factor responsible for a change in the mechanical response of the colon. The age of the subjects and the shelf-life of the bodies did not represent factors influencing the mechanical behavior of the colon (p > 0.05). INTERPRETATION The mechanical response of the colon tissue showed a biphasic injury process depending on gender and method of preservation. The age and shelf-life of anatomical subjects do not alter the mechanical response of the colon.
Collapse
Affiliation(s)
- D Massalou
- Emergency Surgery Unit, University Hospital of Nice, CHU de Nice Hôpital Pasteur 2, Université de Nice Sophia-Antipolis, France; Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| | - C Masson
- Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| | - S Afquir
- Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France
| | - P Baqué
- Emergency Surgery Unit, University Hospital of Nice, CHU de Nice Hôpital Pasteur 2, Université de Nice Sophia-Antipolis, France.
| | - P-J Arnoux
- Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| | - T Bège
- Department of Visceral Surgery, AP-HM Hôpital Nord, Aix-Marseille University, France; Biomechanical Applied Laboratory, UMRT24, IFSTTAR, Aix-Marseille University, France.
| |
Collapse
|
28
|
Siri S, Maier F, Chen L, Santos S, Pierce DM, Feng B. Differential biomechanical properties of mouse distal colon and rectum innervated by the splanchnic and pelvic afferents. Am J Physiol Gastrointest Liver Physiol 2019; 316:G473-G481. [PMID: 30702901 PMCID: PMC6483024 DOI: 10.1152/ajpgi.00324.2018] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Visceral pain is one of the principal complaints of patients with irritable bowel syndrome, and this pain is reliably evoked by mechanical distension and stretch of distal colon and rectum (colorectum). This study focuses on the biomechanics of the colorectum that could play critical roles in mechanical neural encoding. We harvested the distal 30 mm of the colorectum from mice, divided evenly into three 10-mm-long segments (colonic, intermediate and rectal), and conducted biaxial mechanical stretch tests and opening-angle measurements for each tissue segment. In addition, we determined the collagen fiber orientations and contents across the thickness of the colorectal wall by nonlinear imaging via second harmonic generation (SHG). Our results reveal a progressive increase in tissue compliance and prestress from colonic to rectal segments, which supports prior electrophysiological findings of distinct mechanical neural encodings by afferents in the lumbar splanchnic nerves (LSN) and pelvic nerves (PN) that dominate colonic and rectal innervations, respectively. The colorectum is significantly more viscoelastic in the circumferential direction than in the axial direction. In addition, our SHG results reveal a rich collagen network in the submucosa and orients approximately ±30° to the axial direction, consistent with the biaxial test results presenting almost twice the stiffness in axial direction versus the circumferential direction. Results from current biomechanical study strongly indicate the prominent roles of local tissue biomechanics in determining the differential mechanical neural encoding functions in different regions of the colorectum. NEW & NOTEWORTHY Mechanical distension and stretch-not heat, cutting, or pinching-reliably evoke pain from distal colon and rectum. We report different local mechanics along the longitudinal length of the colorectum, which is consistent with the existing literature on distinct mechanotransduction of afferents innervating proximal and distal regions of the colorectum. This study draws attention to local mechanics as a potential determinant factor for mechanical neural encoding of the colorectum, which is crucial in visceral nociception.
Collapse
Affiliation(s)
- Saeed Siri
- 1Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut
| | - Franz Maier
- 2Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut
| | - Longtu Chen
- 1Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut
| | - Stephany Santos
- 2Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut
| | - David M. Pierce
- 1Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut,2Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut
| | - Bin Feng
- 1Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut
| |
Collapse
|
29
|
Oetzmann von Sochaczewski C, Tagkalos E, Lindner A, Lang H, Heimann A, Schröder A, Grimminger PP, Muensterer OJ. Esophageal Biomechanics Revisited: A Tale of Tenacity, Anastomoses, and Suture Bite Lengths in Swine. Ann Thorac Surg 2019; 107:1670-1677. [PMID: 30629926 DOI: 10.1016/j.athoracsur.2018.12.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 12/02/2018] [Accepted: 12/04/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Anastomotic tension has repeatedly been associated with anastomotic leakages after esophagectomy for cancer or esophageal atresia repair. We therefore aimed to determine which anastomotic technique would come as close as possible to the native esophagus in sustaining traction forces. Constant traction for several minutes at esophageal remnants and large suture bites are also considered relevant in long-gap esophageal atresia repair. METHODS Porcine esophagi were subjected to linear traction using a motorized horizontal test stand. We compared breaking strengths of native esophagi to simple continuous, simple interrupted, stapled, and barbed suture anastomoses. We also investigated the effects of suture bite length and phases of constant traction on breaking strengths and powered all experiments to at least 80% using exploratory investigations (n = 5 per group). RESULTS Continuous suture anastomoses had a breaking strength comparable to native esophagi (Δ = -5.25 Newton, 95% confidence interval: -10.69 to 0.19 Newton, p = 0.058) and outperformed all other investigated anastomoses (Δ ≥14.01 Newton, p ≤ 0.02). Breaking strength correlated with suture bite length (R = 0.905) and predicted breaking strength for the simple stitch (adjusted R2 = 0.812, p < 0.0001), but not for anastomoses. Phases of incrementally increasing constant traction resulted in higher breaking strengths (Δ = 13.36 Newton, 95% confidence interval: 9.93 to 16.79 Newton, p < 0.0001) and higher length gain (Δ = 1.06 cm, 95% confidence interval: 0.65 to 1.48 cm, p < 0.0001) compared with controls. CONCLUSIONS Only simple continuous anastomoses achieved the linear breaking strength of native tissue. Our study provides important insights in tolerance to traction forces, but its results have to be corroborated in living animals as anastomotic leakages are multifactorial processes.
Collapse
Affiliation(s)
| | - Evangelos Tagkalos
- Department of General, Visceral, and Transplant Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Andreas Lindner
- Department of Pediatric Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Hauke Lang
- Department of General, Visceral, and Transplant Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Axel Heimann
- Institute for Neurosurgical Pathophysiology, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Arne Schröder
- Department of Anesthesiology, Marienkrankenhaus Bergisch-Gladbach, Germany
| | - Peter P Grimminger
- Department of General, Visceral, and Transplant Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| | - Oliver J Muensterer
- Department of Pediatric Surgery, Universitätsmedizin der Johannes-Gutenberg-Universität, Mainz, Germany
| |
Collapse
|
30
|
White EJ, Cunnane EM, McMahon M, Walsh MT, Coffey JC, O'Sullivan L. Mechanical characterisation of porcine non-intestinal colorectal tissues for innovation in surgical instrument design. Proc Inst Mech Eng H 2018; 232:796-806. [PMID: 30035663 DOI: 10.1177/0954411918788595] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
This article presents an investigation into the mechanical properties of porcine mesocolon, small intestinal mesentery, fascia, and peritoneum tissues to generate a preliminary database of the mechanical characteristics of these tissues as surrogates for human tissue. No study has mechanically characterised porcine tissue correlates of the mesentery and associated structures. The samples were tested to determine the strength, stretch at failure, and stiffness of each tissue. The results indicated that porcine mesenteric and associated tissues visually resembled corresponding human tissues and had similar tactile characteristics, according to an expert colorectal surgeon. Stiffness values ranged from 0.088 MPa to 6.858 MPa across all tissues, with fascia being the weakest, and mesentery and peritoneum being the strongest. Failure stress values ranged from 0.336 MPa to 6.517 MPa, and failure stretch values ranged from 1.766 to 3.176, across all tissues. These mechanical data can serve as reference baseline data upon which future work can expand.
Collapse
Affiliation(s)
- Eoin J White
- 1 School of Design, University of Limerick, Limerick, Ireland
| | - Eoghan M Cunnane
- 2 School of Engineering, University of Limerick, Limerick, Ireland
| | - Muireann McMahon
- 1 School of Design, University of Limerick, Limerick, Ireland.,3 Health Research Institute, University of Limerick, Limerick, Ireland
| | - Michael T Walsh
- 2 School of Engineering, University of Limerick, Limerick, Ireland.,3 Health Research Institute, University of Limerick, Limerick, Ireland.,4 Bernal Institute, University of Limerick, Limerick, Ireland
| | - J Calvin Coffey
- 3 Health Research Institute, University of Limerick, Limerick, Ireland.,5 Graduate Entry Medical School, University of Limerick, Limerick, Ireland.,6 Department of Colorectal Surgery, University Hospitals Limerick, Limerick, Ireland
| | - Leonard O'Sullivan
- 1 School of Design, University of Limerick, Limerick, Ireland.,3 Health Research Institute, University of Limerick, Limerick, Ireland
| |
Collapse
|
31
|
Stewart DC, Berrie D, Li J, Liu X, Rickerson C, Mkoji D, Iqbal A, Tan S, Doty AL, Glover SC, Simmons CS. Quantitative assessment of intestinal stiffness and associations with fibrosis in human inflammatory bowel disease. PLoS One 2018; 13:e0200377. [PMID: 29995938 PMCID: PMC6040714 DOI: 10.1371/journal.pone.0200377] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Accepted: 06/25/2018] [Indexed: 01/05/2023] Open
Abstract
Inflammatory bowel disease (IBD) continues to increase in prevalence in industrialized countries. Major complications of IBD include formation of fibrotic strictures, fistulas, reduced absorptive function, cancer risk, and the need for surgery. In other chronic gastrointestinal disease models, stiffness has been shown to precede fibrosis; therefore, stiffness may be a reasonable indicator of progression toward stricture formation in IBD patients. Herein, we seek to quantify tissue stiffness and characterize fibrosis in patients with IBD and to compare mechanical properties of unaffected human tissue to common animal species used for IBD studies. Inflamed and unaffected tissue from IBD patients and unaffected tissue from mice, pigs, and cows were indented using a custom device to determine the effective stiffness. Histology was performed on matched tissues, and total RNA was isolated from IBD tissue samples and used for gene expression analysis of pro-fibrotic genes. We observed an increase in the effective stiffness (steady-state modulus, SSM) (p < 0.0001) and increased expression of the collagen type I gene (COL1A1, p = 0.01) in inflamed tissue compared to unaffected areas in our IBD patient cohort. We also found that increased staining of collagen fibers in submucosa positively correlated with SSM (p = 0.093). We determined that unaffected animal bowel stiffness is significantly greater than similar human tissues, suggesting additional limitations on animal models for translational investigations regarding stiffness-related hypotheses. Taken together, our data support development of tools for evaluation of bowel stiffness in IBD patients for prognostic applications that may enable more accurate prediction of those who will develop fibrosis and more precise prescription of aggressive therapies.
Collapse
Affiliation(s)
- Daniel C. Stewart
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, United States of America
| | - Dalton Berrie
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, United States of America
- Division of Gastroenterology, Hepatology and Nutrition, College of Medicine, University of Florida, Gainesville, FL, United States of America
| | - Jian Li
- Division of Gastroenterology, Hepatology and Nutrition, College of Medicine, University of Florida, Gainesville, FL, United States of America
| | - Xinyue Liu
- Department of Pharmaceutical Outcomes and Policy, College of Pharmacy, University of Florida, Gainesville, FL, United States of America
| | - Cooper Rickerson
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, United States of America
| | - David Mkoji
- Department of Mechanical and Aerospace Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, United States of America
| | - Atif Iqbal
- Department of Surgery, College of Medicine, University of Florida, Gainesville, FL, United States of America
| | - Sanda Tan
- Department of Surgery, College of Medicine, University of Florida, Gainesville, FL, United States of America
| | - Andria L. Doty
- Division of Gastroenterology, Hepatology and Nutrition, College of Medicine, University of Florida, Gainesville, FL, United States of America
| | - Sarah C. Glover
- Division of Gastroenterology, Hepatology and Nutrition, College of Medicine, University of Florida, Gainesville, FL, United States of America
| | - Chelsey S. Simmons
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, United States of America
- Department of Mechanical and Aerospace Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, United States of America
- Division of Cardiovascular Medicine, College of Medicine, University of Florida, Gainesville, FL, United States of America
| |
Collapse
|
32
|
Patel B, Chen H, Ahuja A, Krieger JF, Noblet J, Chambers S, Kassab GS. Constitutive modeling of the passive inflation-extension behavior of the swine colon. J Mech Behav Biomed Mater 2017; 77:176-186. [PMID: 28922650 DOI: 10.1016/j.jmbbm.2017.08.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 08/24/2017] [Accepted: 08/28/2017] [Indexed: 12/14/2022]
Abstract
In the present work, we propose the first structural constitutive model of the passive mechanical behavior of the swine colon that is validated against physiological inflation-extension tests, and accounts for residual strains. Sections from the spiral colon and the descending colon were considered to investigate potential regional variability. We found that the proposed constitutive model accurately captures the passive inflation-extension behavior of both regions of the swine colon (coefficient of determination R2=0.94±0.02). The model revealed that the circumferential muscle layer does not provide significant mechanical support under passive conditions and the circumferential load is actually carried by the submucosa layer. The stress analysis permitted by the model showed that the colon tissue can distend up to 30% radially without significant increase in the wall stresses suggesting a highly compliant behavior of the tissue. This is in-line with the requirement for the tissue to easily accommodate variable quantities of fecal matter. The analysis also showed that the descending colon is significantly more compliant than the spiral colon, which is relevant to the storage function of the descending colon. Histological analysis showed that the swine colon possesses a four-layer structure similar to the human colon, where the longitudinal muscle layer is organized into bands called taeniae, a typical feature of the human colon. The model and the estimated parameters can be used in a Finite Element framework to conduct simulations with realistic geometry of the swine colon. The resulting computational model will provide a foundation for virtual assessment of safe and effective devices for the treatment of colonic diseases.
Collapse
Affiliation(s)
- Bhavesh Patel
- California Medical Innovations Institute, 11107 Roselle st., San Diego, CA 92121, United States
| | - Huan Chen
- California Medical Innovations Institute, 11107 Roselle st., San Diego, CA 92121, United States
| | - Aashish Ahuja
- California Medical Innovations Institute, 11107 Roselle st., San Diego, CA 92121, United States
| | | | | | | | - Ghassan S Kassab
- California Medical Innovations Institute, 11107 Roselle st., San Diego, CA 92121, United States.
| |
Collapse
|
33
|
Christensen MB, Oberg K, Wolchok JC. Tensile properties of the rectal and sigmoid colon: a comparative analysis of human and porcine tissue. SPRINGERPLUS 2015; 4:142. [PMID: 25977885 PMCID: PMC4414857 DOI: 10.1186/s40064-015-0922-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2014] [Accepted: 03/11/2015] [Indexed: 01/19/2023]
Abstract
For many patients, rectal catheters are an effective means to manage bowel incontinence. Unfortunately, the incidence of catheter leakage in these patients remains troublingly high. Matching the mechanical properties of the catheter and the surrounding tissue may improve the catheter seal and reduce leakage. However, little data is available on the mechanical properties of colorectal tissue. Therefore, our group examined the mechanical properties of colorectal tissue obtained from both a common animal model and humans. Uniaxial tension tests were performed to determine the effects of location, orientation, and species (porcine and human) on bowel tissue tensile mechanical properties. Bowel tissue ultimate strength, elongation at failure, and elastic modulus were derived from these tests and statistically analyzed. Ultimate tensile strength (0.58 MPa, 0.87 MPa), elongation at failure (113.19%, 62.81%), and elastic modulus (1.83 MPa, 5.18 MPa) for porcine and human samples respectively exhibited significant differences based on species. Generally, human tissues were stronger and less compliant than their porcine counterparts. Furthermore, harvest site location and testing orientation significantly affected several mechanical properties in porcine derived tissues, but very few in human tissues. The data suggests that porcine colorectal tissue does not accurately model human colorectal tissue mechanical properties. Ultimately, the tensile properties reported herein may be used to help guide the design of next generation rectal catheters with tissue mimetic properties, as well as aid in the development of physical and computer based bowel models.
Collapse
Affiliation(s)
- Michael B Christensen
- Keck Center for Tissue Engineering, Department of Bioengineering, University of Utah, 36 S Wasatch Dr. Rm 3100, Salt Lake City, UT 84112 USA
| | - Kevin Oberg
- Keck Center for Tissue Engineering, Department of Bioengineering, University of Utah, 36 S Wasatch Dr. Rm 3100, Salt Lake City, UT 84112 USA
| | - Jeffrey C Wolchok
- Department of Biomedical Engineering, University of Arkansas, 120 Engineering Hall, Fayetteville, AR 72701 USA
| |
Collapse
|