1
|
Lin S, Reisdorf R, Lu CK, Wang Z, An KN, Moran SL, Amadio PC, Zhao C. Cell-based tissue engineered flexor tendon allograft: A canine in vivo study. J Orthop Res 2024; 42:1923-1932. [PMID: 38639414 PMCID: PMC11293999 DOI: 10.1002/jor.25854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 01/31/2024] [Accepted: 03/30/2024] [Indexed: 04/20/2024]
Abstract
This study aimed to compare the clinically established autologous extrasynovial tendon graft to a newly developed tissue-engineered allograft (Eng-allograft) in terms of functional outcomes following flexor tendon reconstruction in a canine model. The second and fifth flexor digitorum profundus (FDP) tendons from 16 dogs were transected and repaired in Zone II. After 6 weeks of cage activity, the repaired tendons were intentionally ruptured, creating a clinically relevant model for reconstruction. The re-ruptured FDP tendons were then reconstructed using either the clinically standard autologous extrasynovial tendon graft or the Eng-allograft, which had been revitalized with autologous bone marrow-derived mesenchymal stem cells (BMSCs) and synovialized using carbodiimide derivatized synovial fluid (cd-SYN). Following 12 weeks of postoperative rehabilitation, the functional outcomes of the surgical digits were evaluated. The Eng-allograft group exhibited improved digital function, including lower digit work of flexion and reduced adhesion status, while maintaining similar tendon gliding resistance compared to the autograft group. However, the failure load of both the distal and proximal host/graft conjunctions in the Eng-allograft group was significantly lower than that of the autograft group with higher graft rupture at the host-graft junction. In conclusion, the decellularized allogenic intrasynovial tendon, when revitalized BMSCs and synovialized with cd-SYN, demonstrates positive effects on digital function improvement and adhesion reduction. However, the healing at both proximal and distal graft/host junctions is far lower than the autograft. Further research is needed to enhance the healing capacity of allograft conjunctions, aiming to achieve a comparable level of healing seen with autografts.
Collapse
Affiliation(s)
- Subin Lin
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
- Department of Orthopedics, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, P.R. China
| | - Ramona Reisdorf
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Chun Kuan Lu
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Zhanwen Wang
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Kai-Nan An
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Steven L. Moran
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Peter C. Amadio
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Chunfeng Zhao
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
2
|
Lutter C, Hiller N, Sass J, Hembus J, Jones G, Vogel D, Groß J, Bader R, Tischer T. Refixation of the anterior cruciate ligament: A biomechanical analysis of suture techniques in a porcine model. J Exp Orthop 2024; 11:e12011. [PMID: 38497044 PMCID: PMC10941523 DOI: 10.1002/jeo2.12011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Accepted: 02/02/2024] [Indexed: 03/19/2024] Open
Abstract
Purpose Refixation of acute anterior cruciate ligament (ACL) tears represents an increasingly popular treatment option. Systematic evaluations of various suture technique parameters are still pending. We therefore aimed to evaluate the mechanical pull-out outcomes of various suture methods for optimization of ACL refixation. Methods Sixty fresh knees from mature domestic pigs were dissected and the femoral attachment of the ACL was peeled off. The 60 knees were divided in 10 groups and sutured as follows: (A) one suture (1, 2, 4 and 6 passes), (B) two sutures (2, 4 and 6 passes each; sutures knotted together as a loop) and (C) two sutures (2, 4 and 6 passes each, sutures knotted separately). The pull-out test was conducted using a validated electrodynamic testing machine. First occurrence of failure, maximum pull-out load and stiffness were measured. Suture failure was defined as pull-out of the ACL. Results Two-point fixation, using two sutures, with at least two passes, showed the most favourable biomechanical stability. The maximum pull-out load was significantly higher with two sutures (529.5 N) used compared to one (310.4 N), p < 0.001. No significant differences were found for maximum pull-out loads between two-point fixation versus one-point fixation but stiffness was significantly higher with two-point fixation (107.4 N/mm vs. 79.4 N/mm, p < 0.001). More passes resulted in higher maximum pull-out loads. Conclusion The results suggest using two independent sutures, refixed separately and at least two suture passes, is appropriate for ACL refixation. More suture passes provide additional strength but are technically challenging to achieve during surgery. Level of Evidence Level IV.
Collapse
Affiliation(s)
- Christoph Lutter
- Department of OrthopaedicsRostock University Medical CenterRostockGermany
| | - Natalie Hiller
- Department of OrthopaedicsRostock University Medical CenterRostockGermany
| | - Jan‐Oliver Sass
- Department of OrthopaedicsRostock University Medical CenterRostockGermany
| | - Jessica Hembus
- Department of OrthopaedicsRostock University Medical CenterRostockGermany
| | - Gareth Jones
- School of Clinical and Applied SciencesLeeds Beckett UniversityLeedsUK
| | - Danny Vogel
- Department of OrthopaedicsRostock University Medical CenterRostockGermany
| | - Justus Groß
- Department for General, Visceral, Thoracic, Vascular and Transplantation SurgeryUniversity Hospital RostockRostockGermany
| | - Rainer Bader
- Department of OrthopaedicsRostock University Medical CenterRostockGermany
| | - Thomas Tischer
- Department of OrthopaedicsRostock University Medical CenterRostockGermany
| |
Collapse
|
3
|
Itoh M, Itou J, Imai S, Okazaki K, Iwasaki K. A survey on the usage of decellularized tissues in orthopaedic clinical trials. Bone Joint Res 2023; 12:179-188. [PMID: 37051813 PMCID: PMC10032226 DOI: 10.1302/2046-3758.123.bjr-2022-0383.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/14/2023] Open
Abstract
Orthopaedic surgery requires grafts with sufficient mechanical strength. For this purpose, decellularized tissue is an available option that lacks the complications of autologous tissue. However, it is not widely used in orthopaedic surgeries. This study investigated clinical trials of the use of decellularized tissue grafts in orthopaedic surgery. Using the ClinicalTrials.gov (CTG) and the International Clinical Trials Registry Platform (ICTRP) databases, we comprehensively surveyed clinical trials of decellularized tissue use in orthopaedic surgeries registered before 1 September 2022. We evaluated the clinical results, tissue processing methods, and commercial availability of the identified products using academic literature databases and manufacturers' websites. We initially identified 4,402 clinical trials, 27 of which were eligible for inclusion and analysis, including nine shoulder surgery trials, eight knee surgery trials, two ankle surgery trials, two hand surgery trials, and six peripheral nerve graft trials. Nine of the trials were completed. We identified only one product that will be commercially available for use in knee surgery with significant mechanical load resistance. Peracetic acid and gamma irradiation were frequently used for sterilization. Despite the demand for decellularized tissue, few decellularized tissue products are currently commercially available, particularly for the knee joint. To be viable in orthopaedic surgery, decellularized tissue must exhibit biocompatibility and mechanical strength, and these requirements are challenging for the clinical application of decellularized tissue. However, the variety of available decellularized products has recently increased. Therefore, decellularized grafts may become a promising option in orthopaedic surgery.
Collapse
Affiliation(s)
- Masafumi Itoh
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, Tokyo, Japan
- Institute for Medical Regulatory Science, Comprehensive Research Organization, Waseda University, Tokyo, Japan
- Tokyo Women's Medical University - Waseda University Joint Graduate School, Waseda University, Tokyo, Japan
| | - Junya Itou
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, Tokyo, Japan
- Tokyo Women's Medical University - Waseda University Joint Graduate School, Waseda University, Tokyo, Japan
| | - Shinya Imai
- Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan
| | - Ken Okazaki
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, Tokyo, Japan
- Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan
| | - Kiyotaka Iwasaki
- Institute for Medical Regulatory Science, Comprehensive Research Organization, Waseda University, Tokyo, Japan
- Tokyo Women's Medical University - Waseda University Joint Graduate School, Waseda University, Tokyo, Japan
- Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan
- Department of Mordern Mechanical Engineering, School of Creative Science and Engineering, Waseda University, Tokyo, Japan
| |
Collapse
|
4
|
Smolle MA, Fischerauer SF, Zötsch S, Kiegerl AV, Sadoghi P, Gruber G, Leithner A, Bernhardt GA. Long-term outcomes of surgery using the Ligament Advanced Reinforcement System as treatment for anterior cruciate ligament tears. Bone Joint J 2022; 104-B:242-248. [PMID: 35094581 DOI: 10.1302/0301-620x.104b2.bjj-2021-0798.r2] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
AIMS The aim of this prospective study was to assess the long-term clinical, radiological, functional, and quality of life (QoL)-related outcome of patients treated with the synthetic Ligament Advanced Reinforcement System (LARS) device for anterior cruciate ligament (ACL) rupture. METHODS A total of 41 patients who underwent ACL reconstruction with the LARS device (mean age 39.8 years (SD 12.1 ); 32% females (n = 13)) were prospectively included between August 2001 and March 2005. MRI scans and radiographs were performed at a median follow-up of 2.0 years (interquartile range (IQR) 1.3 to 3.0; n = 40) and 12.8 years (IQR 12.1 to 13.8; n = 22). Functional and QoL-related outcome was assessed in 29 patients at a median follow-up of 12.8 years (IQR 12.0 to 14.0) and clinically reconfirmed at latest median follow-up of 16.5 years (IQR 15.5 to 17.9). International Knee Documentation Committee (IKDC) and Tegner scores were obtained pre- and postoperatively, and Lysholm score postoperatively only. At latest follow-up, range of motion, knee stability tests, 36-Item Short Form Health Survey (SF-36), and IKDC scores were ascertained. Complications and reoperations during follow-up were documented. RESULTS Cumulative complication rate was 66% (n = 27), with 11 developing within one year from surgery and 16 after one year (including five patients with both early and late complications). Ten graft failures (24%) and eight cases of reactive synovitis were observed (20%). All 11 patients with early complications and ten with late complications underwent reoperation (including five with another surgical procedure for early complications), amounting to a cumulative reoperation rate of 51% (n = 21). Revision ACL reconstruction was performed in one patient (2.4%). Median IKDC at latest follow-up was 89.7 (IQR 78.2 to 93.1), being significantly worse in the event of previous complications. Lachman test was positive in 56% (n = 15) of reconstructed knees. All norm-based SF-36 items were at or above median at latest follow-up, and did not differ depending on development of complications. CONCLUSION Despite good functional and QoL-related results in the long term, the cumulative complication rate of 66%, including graft failures and reactive synovitis, has to be viewed with great concern. Cite this article: Bone Joint J 2022;104-B(2):242-248.
Collapse
Affiliation(s)
- Maria A Smolle
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| | - Stefan F Fischerauer
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| | - Silvia Zötsch
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| | - Anna V Kiegerl
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| | - Patrick Sadoghi
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| | - Gerald Gruber
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| | - Gerwin A Bernhardt
- Department of Orthopaedics and Trauma, Medizinische Universitat Graz, Graz, Austria
| |
Collapse
|
5
|
Glasbrenner J, Fischer M, Raschke MJ, Briese T, Müller M, Herbst E, Kittl C, Schliemann B, Kösters C. Primary stability of single-stage revision reconstruction of the anterior cruciate ligament in case of failure of dynamic intraligamentary stabilization depends on implant position during ACL repair. Arch Orthop Trauma Surg 2022; 142:1589-1595. [PMID: 34331580 PMCID: PMC9217861 DOI: 10.1007/s00402-021-04088-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 07/21/2021] [Indexed: 11/25/2022]
Abstract
INTRODUCTION The object of this study was to evaluate the primary stability of tibial interference screw (IFS) fixation in single-stage revision surgery of the anterior cruciate ligament (ACL) in the case of recurrent instability after ACL repair with dynamic intraligamentary stabilization (DIS), dependent on the implant position during DIS. MATERIALS AND METHODS Tibial aperture fixation in ACL reconstruction (ACL-R) was performed in a porcine knee model using an IFS. Native ACL-R was performed in the control group (n = 15). In the intervention groups DIS and subsequent implant removal were performed prior to single-stage revision ACL-R. A distance of 20 mm in group R-DIS1 (n = 15) and 5 mm in group R-DIS2 (n = 15) was left between the joint line and the implant during DIS. Specimens were mounted in a material-testing machine and load-to-failure was applied in a worst-case-scenario. RESULTS Load to failure was 454 ± 111 N in the R-DIS1 group, 154 ± 71 N in the R-DIS2 group and 405 ± 105 N in the primary ACL-R group. Load-to-failure, stiffness and elongation of the group R-DIS2 were significantly inferior in comparison to R-DIS1 and ACL-R respectively (p < 0.001). No significant difference was found between load-to-failure, stiffness and elongation of R-DIS1 and the control group. CONCLUSION Primary stability of tibial aperture fixation in single-stage revision ACL-R in case of recurrent instability after DIS depends on monobloc position during ACL repair. Primary stability is comparable to aperture fixation in primary ACL-R, if a bone stock of 20 mm is left between the monobloc and the tibial joint line during the initial procedure.
Collapse
Affiliation(s)
- J Glasbrenner
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany.
| | - M Fischer
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany
| | - M J Raschke
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany
| | - T Briese
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany
| | - M Müller
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany
| | - E Herbst
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany
| | - C Kittl
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany
| | - B Schliemann
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building W1, 48149, Münster, Germany
| | - C Kösters
- Department of Traumatology and Orthopedics, Maria-Josef-Hospital Greven, Lindenstraße 29, 48268, Greven, Germany
| |
Collapse
|
6
|
Marchiori G, Berni M, Cassiolas G, Vivarelli L, Lopomo NF, Fini M, Dallari D, Govoni M. Extra-Corporeal Membrane Oxygenation Cadaver Donors: What about Tissues Used as Allografts? MEMBRANES 2021; 11:membranes11070545. [PMID: 34357195 PMCID: PMC8307999 DOI: 10.3390/membranes11070545] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 07/15/2021] [Accepted: 07/16/2021] [Indexed: 01/16/2023]
Abstract
Several studies demonstrated the efficacy of post-mortem extracorporeal membrane oxygenation (ECMO) on donors in preserving organ function addressing organ transplantation. Nevertheless, no common and shared evidence was reached about the possibility of using ECMO donors in tissue harvesting. Therefore, this work aimed first to review the current scientific literature about ECMO donors, and then to focus on the use of ECMO tissues as allografts, mainly addressing musculoskeletal tissues, which are of the most interest for reconstruction. A search was conducted on the current scientific literature, focusing on the keywords "ECMO" and "Donor". Several online databases were used, including PubMed, Scopus, and Web of Science. From the preliminary search, 478 articles were obtained, out of which 173 specifically reported the use of ECMO for donation and transplantation purposes. Literature reported extensive analyses of ECMO organs-overall from the abdomen-both in pre- and post-transplantation studies. On the other hand, ECMO tissues were explanted only in a very limited number of cases; moreover, no information was referred about their status and use. A revision of the current scientific literature highlighted the lack of information concerning ECMO tissues and the necessity to perform preclinical, ex vivo studies to compare allografts from ECMO donors, with respect to standard donors, and, thus, to verify whether they can be harvested and implanted safely and with efficacy.
Collapse
Affiliation(s)
- Gregorio Marchiori
- Surgical Sciences and Technologies Complex Structure, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy; (G.M.); (M.F.)
| | - Matteo Berni
- Medical Technology Laboratory Complex Structure, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy;
| | - Giorgio Cassiolas
- Department of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy; (G.C.); (N.F.L.)
| | - Leonardo Vivarelli
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, 40136 Bologna, Italy; (D.D.); (M.G.)
- Correspondence:
| | - Nicola Francesco Lopomo
- Department of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy; (G.C.); (N.F.L.)
| | - Milena Fini
- Surgical Sciences and Technologies Complex Structure, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy; (G.M.); (M.F.)
| | - Dante Dallari
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, 40136 Bologna, Italy; (D.D.); (M.G.)
| | - Marco Govoni
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, 40136 Bologna, Italy; (D.D.); (M.G.)
| |
Collapse
|
7
|
Marchiori G, Lopomo NF, Bologna E, Spadaro D, Camarda L, Berni M, Visani A, Zito M, Zaffagnini S, Zingales M. How preconditioning and pretensioning of grafts used in ACLigaments surgical reconstruction are influenced by their mechanical time-dependent characteristics: Can we optimize their initial loading state? Clin Biomech (Bristol, Avon) 2021; 83:105294. [PMID: 33667940 DOI: 10.1016/j.clinbiomech.2021.105294] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 02/08/2021] [Accepted: 02/12/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE Consensus about a pre-implant preparation protocol adaptable to any graft used in Anterior Cruciate Ligament reconstruction is still lacking. In fact, there is not agreement on reliable metrics that consider both specific graft dimensional characteristics, such as its diameter, and the inherent properties of its constitutive material, i.e. ligaments or tendons. Aim of the present study was to investigate and propose the applied engineering stress as a possible metrics. METHODS Preconditioning and pretensioning protocol involved groups of grafts with different section (10 or 32 mm2) and materials (i.e. human patellar and hamstring tendons, and synthetic grafts). A 140 N load was applied to the grafts and maintained for 100 s. Initial stress and following stress-relaxation (a mechanical characteristic that can be related to knee laxity) were specifically analysed. FINDINGS Initial stress, ranging between 4 and 12 MPa, was affected primarily by the graft cross-section area and secondarily by the choice of the graft material. In terms of loss of the initial stress, stress-relaxation behaviour varied instead on a narrower range, namely 13-17%. INTERPRETATION Engineering stress can be identified as the correct metrics to optimize the initial state of each graft to avoid excessive stiffness, laxity or fatigue rupture phenomena.
Collapse
Affiliation(s)
- Gregorio Marchiori
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Scienze e Tecnologie Chirurgiche, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Nicola Francesco Lopomo
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Scienze e Tecnologie Chirurgiche, Via di Barbiano 1/10, 40136 Bologna, Italy; Department of Information Engineering, University of Brescia, Via Branze 38, 25123, Brescia, Italy
| | - Emanuela Bologna
- Engineering Department, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy; Bio/NanoMechanics for Medical Sciences Laboratory, ATeN-Center, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy
| | - Doriana Spadaro
- Fallprotec SA, 43-45 ZA Op Zaemer, 4959 Bascharage, Luxembourg
| | - Lawrence Camarda
- Department of Discipline Surgical, Oncology and Dentistry, University of Palermo, Via Liborio Giuffrè, 5, 90127, Palermo, Italy
| | - Matteo Berni
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Andrea Visani
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Scienze e Tecnologie Chirurgiche, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Marianna Zito
- Engineering Department, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy
| | - Stefano Zaffagnini
- IRCCS Istituto Ortopedico Rizzoli, IIa Clinica Ortopedica e Traumatologica, Via Pupilli 1/10, 40136 Bologna, Italy
| | - Massimiliano Zingales
- Engineering Department, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy; Bio/NanoMechanics for Medical Sciences Laboratory, ATeN-Center, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy.
| |
Collapse
|
8
|
Van Der Merwe W, Lind M, Faunø P, Van Egmond K, Zaffagnini S, Marcacci M, Cugat R, Verdonk R, Ibañez E, Guillen P, Marcheggiani Muccioli GM. Xenograft for anterior cruciate ligament reconstruction was associated with high graft processing infection. J Exp Orthop 2020; 7:79. [PMID: 33026544 PMCID: PMC7541808 DOI: 10.1186/s40634-020-00292-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 09/21/2020] [Indexed: 11/10/2022] Open
Abstract
Purpose To evaluate clinical ad radiological outcomes of anterior cruciate ligament (ACL) reconstruction with an immunochemically modified porcine patellar tendon xenograft controlled against human Achilles tendon allograft at 24-month minimum follow-up. Methods 66 patients undergoing arthroscopic ACL reconstruction were randomized into 2 groups: 34 allografts and 32 xenografts treated to attenuate the host immune response. Follow-up was 24-month minimum. Anterior knee stability was measured as KT − 1000 side-to-side laxity difference (respect to the contralateral healthy knee). Functional performance was assessed by one-legged hop test. Objective manual pivot-shift test and subjective (IKDC, Tegner and SF-36) outcomes were collected. MRI and standard X-Ray were performed. Results 61 subjects (32 allograft, 29 xenograft) were evaluated at 12 and 24 months. Six of the subjects in xenograft group (20.6%) got an infection attributed to a water-based pathogen graft contamination in processing. Intention-to-treat analysis (using the last observation carried forward imputation method) revealed higher KT − 1000 laxity in xenograft group at 24-month follow-up (P = .042). Also pivot-shift was higher in xenograft group at 12-month (P = .015) and 24-month follow-up (P = .038). Per-protocol analysis (missing/contaminated subjects excluded) did not revealed clinical differences between groups. Tibial tunnel widening in the allograft group was low, whereas xenograft tunnel widening was within the expected range of 20–35% as reported in the literature. No immunological reactivity was associated to xenograft group. Conclusions High infection rate (20.6%) was reported in xenograft group. Both groups of patients achieved comparable clinical outcomes if missing/contaminated subjects are excluded. Improved harvesting/processing treatments in future studies using xenografts for ACL reconstruction are needed to reduce infection rate, otherwise xenograft should not be used in ACL reconstruction. Level of evidence Multicenter and double-blinded Randomized Controlled Clinical Trial, Level I.
Collapse
Affiliation(s)
| | | | | | - Kees Van Egmond
- Dept. of Orthopaedic Surgery, Isala Klinieken, Zwolle, Netherlands
| | - Stefano Zaffagnini
- IRCCS Istituto Ortopedici Rizzoli, University of Bologna, Lab. Biomeccanica - Via di Barbiano, 1/10, 40137, Bologna, Italy
| | - Maurilio Marcacci
- IRCCS Humanitas University, Milano / former Istituto Ortopedici Rizzoli, University of Bologna, II Clinica Ortopedica, Bologna, Italy
| | - Ramon Cugat
- Hospital Quiron, Artoscopia GC, Barcelona, Spain
| | - Rene Verdonk
- Dept. of Orthopaedic Surgery & Traumatology, Gent Univ. Hospital, Ghent, Belgium
| | - Enrique Ibañez
- Clinica Cemtro, Orthopaedic Surgery & Traumatology, Madrid, Spain
| | - Pedro Guillen
- Clinica Cemtro, Orthopaedic Surgery & Traumatology, Madrid, Spain
| | | |
Collapse
|
9
|
Hevesi M, Crispim JF, Paggi CA, Dudakovic A, van Genechten W, Hewett T, Kakar S, Krych AJ, van Wijnen AJ, Saris DBF. A Versatile Protocol for Studying Anterior Cruciate Ligament Reconstruction in a Rabbit Model. Tissue Eng Part C Methods 2020; 25:191-196. [PMID: 30887885 DOI: 10.1089/ten.tec.2018.0357] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Anterior cruciate ligament (ACL) injuries are frequent, as >200,000 injuries occur in the United States alone each year. Owing to the risks for associated meniscus and cartilage damage, ACL injuries are a significant source of both orthopedic care and research. Given the extended recovery course after ACL injury, which often lasts 1-2 years, and is associated with limited participation in sports and activities of daily living for patients, there is a critical need for the evolution of new and improved methods for ACL repair. Subsequently, animal models of ACL reconstruction (ACLR) play a key role in the development and initial trialing of novel ACL interventions. This article provides a clear operative description and associated illustrations for a validated, institutional animal care and use committee, and veterinarian approved and facile model of ACLR to serve researchers investigating ACLR.
Collapse
Affiliation(s)
- Mario Hevesi
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - João F Crispim
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
- 2 Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Carlo A Paggi
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Amel Dudakovic
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Timothy Hewett
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Sanjeev Kakar
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Aaron J Krych
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Daniel B F Saris
- 1 Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
- 3 Department of Orthopaedics, University Medical Center, Utrecht, Netherlands
| |
Collapse
|
10
|
Whitaker S, Edwards JH, Guy S, Ingham E, Herbert A. Stratifying the mechanical performance of a decellularized xenogeneic tendon graft for anterior cruciate ligament reconstruction as a function of graft diameter: An animal study. Bone Joint Res 2019; 8:518-525. [PMID: 31832171 PMCID: PMC6888738 DOI: 10.1302/2046-3758.811.bjr-2019-0065.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
Objectives This study investigated the biomechanical performance of decellularized porcine superflexor tendon (pSFT) grafts of varying diameters when utilized in conjunction with contemporary ACL graft fixation systems. This aimed to produce a range of ‘off-the-shelf’ products with predictable mechanical performance, depending on the individual requirements of the patient. Methods Decellularized pSFTs were prepared to create double-bundle grafts of 7 mm, 8 mm, and 9 mm diameter. Femoral and tibial fixation systems were simulated utilizing Arthrex suspension devices and interference screws in bovine bone, respectively. Dynamic stiffness and creep were measured, followed by ramp to failure from which linear stiffness and load at failure were measured. The mechanisms of failure were also recorded. Results Dynamic stiffness was found to increase with greater graft diameter, with significant differences between all groups. Conversely, dynamic creep reduced with increasing graft diameter with significant differences between the 7 mm and 9 mm groups and the 8 mm and 9 mm groups. Significant differences were also found between the 7 mm, 8 mm, and 9 mm groups for linear stiffness, but no significant differences were found between groups for load at failure. The distribution of failure mechanisms was found to change with graft diameter. Conclusion This study showed that decellularized pSFTs demonstrate comparable biomechanical properties to other ACL graft options and are a potentially viable option for ACL reconstruction. Although grafts can be stratified by their diameter to provide varying biomechanical properties, it may be more appropriate to alter the fixation technique to stratify for a greater diversity of biomechanical requirements. Cite this article: Bone Joint Res 2019;8:518–525.
Collapse
Affiliation(s)
| | - Jennifer H Edwards
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| | - Stephen Guy
- Bradford Teaching Hospitals NHS Foundation Trust, Bradford, UK
| | - Eileen Ingham
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| | - Anthony Herbert
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
11
|
Glasbrenner J, Domnick C, Raschke MJ, Willinghöfer T, Kittl C, Michel P, Wähnert D, Herbort M. Adjustable buttons for ACL graft cortical fixation partially fail with cyclic loading and unloading. Knee Surg Sports Traumatol Arthrosc 2019; 27:2530-2536. [PMID: 30368561 DOI: 10.1007/s00167-018-5262-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 10/23/2018] [Indexed: 01/01/2023]
Abstract
PURPOSE Despite good initial pullout strength, it is unclear whether adjustable button (AB) devices for anterior cruciate ligament (ACL) soft-tissue graft fixation, which are based on the Chinese finger trap technique, resist cyclic loading. Furthermore, they have never been tested in a cyclic protocol including complete unloading. It was hypothesized, that the displacement of AB devices with the Chinese finger trap technique would be greater than that of continuous suture loop devices and other available AB mechanisms in a cyclic loading with complete unloading protocol. METHODS ACL reconstruction was performed in a porcine knee model using three different types of cortical fixation devices: two different AB devices that use the Chinese finger trap design, one AB device that uses a locked suture loop mechanism and two different continuous loop devices as control groups (n = 40). Specimens were mounted in a material-testing machine (Instron Inc.) that permitted 2500 loading and complete unloading cycles to a maximum of 250 N, as well as continuous elongation recording. A one-way ANOVA was performed for statistical analysis. RESULTS The displacement of ABs with a Chinese finger trap loop (mean 8.1; SD 1.5 mm and mean 6.1; SD 1.4 mm) was significantly greater than that of AB with a locked suture loop (mean 4.7; SD 1.0 mm; p < 0.05) and devices with a continuous loop (mean 4.1; SD 0.5 mm and mean 4.4, SD 0.3 mm; p < 0.01). No significant differences were detected between the ABs with a locked suture loop and the continuous loops. CONCLUSION Cyclic loading and unloading of AB using the Chinese finger trap technique leads to significantly greater construct lengthening compared with other devices. Complete unloading of the ACL is very likely to occur during rehabilitation after ACL reconstruction. Lengthening of the AB device due to cyclic loading might be a potential mode of failure of the ACL graft fixation. Therefore, when using an AB femoral fixation technique, a locked suture loop design or a careful rehabilitation protocol should be considered.
Collapse
Affiliation(s)
- J Glasbrenner
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany
| | - C Domnick
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany
| | - M J Raschke
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany
| | - T Willinghöfer
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany
| | - C Kittl
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany
| | - P Michel
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany
| | - D Wähnert
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany
| | - Mirco Herbort
- Department of Trauma, Hand and Reconstructive Surgery, Westphalian Wilhelms University, Waldeyer Strasse 1, 48149, Muenster, Germany.
| |
Collapse
|
12
|
Ogata Y, Mabuchi Y, Shinoda K, Horiike Y, Mizuno M, Otabe K, Suto EG, Suzuki N, Sekiya I, Akazawa C. Anterior cruciate ligament-derived mesenchymal stromal cells have a propensity to differentiate into the ligament lineage. Regen Ther 2018; 8:20-28. [PMID: 30271862 PMCID: PMC6149186 DOI: 10.1016/j.reth.2017.12.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 12/07/2017] [Accepted: 12/11/2017] [Indexed: 12/26/2022] Open
Abstract
Introduction The anterior cruciate ligament (ACL) consists of various components, such as collagen, elastin fibres, and fibroblasts. Because ACL has a poor regenerative ability, ACL reconstruction need require the use of autologous tendons. In recent years, tissue-resident stem cells have been studied to promote ACL regeneration as an alternatively method. However, the existence of stem cells in ligaments has not been clearly defined. Here, we prospectively isolated stem cells from ACLs and characterized their properties. Methods ACLs from 11 donors and bone marrows (BM) from 8 donors were obtained with total knee arthroplasty. We used flow cytometry to screen the cell surface markers on ACL cells. Frozen sections were prepared from patient ACL tissues and stained with specific antibodies. Cultured ACL-derived and BM-derived cells at passage 3 were differentiated into adipocytes, osteoblasts and tendon/ligament cells. Results ACL-derived mesenchymal stem/stromal cells (ACL-MSCs) expressed high levels of CD73 and CD90. Immunohistochemical analyses revealed that ACL-MSCs were located on the inner surface of ACL sinusoids. Furthermore, the expression of cell surface antigens was clearly different between ACL-MSCs and bone marrow (BM)-derived MSCs (BM-MSCs) at the time of isolation, but the two cell populations became indistinguishable after long-term culture. Interestingly, ACL-MSCs are markedly different from BM-MSCs in their differentiation ability and have a high propensity to differentiate into ligament-committed cells. Conclusions Our findings suggest that ACL-MSCs express CD90 and CD73 markers, and their differentiation capacity is maintained even through culture. The cell population having tissue-specific properties is an important research target for investigating the ligament therapies. CD73+/90+ cell population in ACL have the highest colony forming ability and can differentiate into mesenchymal lineages. The expression pattern of cell surface antigen in CD73+/90+ ACL-MSCs become similar to that of BM-MSCs during culture. CD73+/90+ ACL-MSCs may be important for ligament regeneration therapies. CD73+/90+ ACL-MSCs may be important for ligament regeneration therapies.
Collapse
Affiliation(s)
- Yusuke Ogata
- Department of Biochemistry and Biophysics, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yo Mabuchi
- Department of Biochemistry and Biophysics, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kosuke Shinoda
- Department of Biochemistry and Biophysics, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuta Horiike
- Department of Biochemistry and Biophysics, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Mitsuru Mizuno
- Center for Stem Cell and Regenerative Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Koji Otabe
- Center for Stem Cell and Regenerative Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Eriko Grace Suto
- Department of Biochemistry and Biophysics, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Nobuharu Suzuki
- Department of Biochemistry and Biophysics, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Ichiro Sekiya
- Center for Stem Cell and Regenerative Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Chihiro Akazawa
- Department of Biochemistry and Biophysics, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
13
|
Welling W, Benjaminse A, Seil R, Lemmink K, Gokeler A. Altered movement during single leg hop test after ACL reconstruction: implications to incorporate 2-D video movement analysis for hop tests. Knee Surg Sports Traumatol Arthrosc 2018; 26:3012-3019. [PMID: 29549389 PMCID: PMC6154044 DOI: 10.1007/s00167-018-4893-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Accepted: 03/08/2018] [Indexed: 12/15/2022]
Abstract
PURPOSE There is a lack of objective factors which can be used in guiding the return to sport (RTS) decision after an anterior cruciate ligament reconstruction (ACLR). The purpose of the current study was to conduct qualitative analysis of the single leg hop (SLH) in patients after ACLR with a simple and clinical friendly method and to compare the possible difference in movement pattern between male and female patients. METHODS Sixty-five patients performed the single leg hop (SLH) test at 6.8 ± 1.0 months following isolated ACLR. Digital video camcorders recorded frontal and sagittal plane views of the patient performing the SLH. Knee flexion at initial contact (IC), peak knee flexion, knee flexion range of motion (RoM), and knee valgus RoM were calculated. In addition, limb symmetry index (LSI) scores were calculated. RESULTS No differences were found in movement pattern between males and females. Movement analysis revealed that males had a decrease in knee flexion at IC (p = 0.018), peak knee flexion (p = 0.002), and knee flexion RoM (p = 0.017) in the injured leg compared to the non-injured leg. Females demonstrated a decrease in peak knee flexion (p = 0.011) and knee flexion RoM (p = 0.023) in the injured leg compared to the non-injured leg. Average LSI scores were 92.4% for males and 94.5% for females. CONCLUSIONS Although LSI scores were > 90%, clinical relevant altered movement patterns were detected in the injured leg compared to the non-injured leg. Caution is warranted to solely rely on LSI scores to determine RTS readiness. CLINICAL TRIAL REGISTRY NAME AND REGISTRATION The University of Groningen, ID 2012.362. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Wouter Welling
- Medisch Centrum Zuid, Sportlaan 2-1, 9728 PH, Groningen, The Netherlands. .,Center for Human Movement Science, University Medical Center Groningen, University of Groningen, Antonius Deusinglaan 1, 9713 AV, Groningen, The Netherlands.
| | - Anne Benjaminse
- Center for Human Movement Science, University Medical Center Groningen, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands ,School of Sport Studies, Hanze University Groningen, Zernikeplein 17, 9747 AS Groningen, The Netherlands
| | - Romain Seil
- Département de l’Appareil Locomoteur, Centre Hospitalier de Luxemburg, 4 Rue Nicolas Ernest Barblé, 1210 Luxembourg, Luxembourg ,Sports Medicine Research Laboratory, Luxembourg Institute of Health, 4 Rue Nicolas Ernest Barblé, 1210 Luxembourg, Luxembourg
| | - Koen Lemmink
- Center for Human Movement Science, University Medical Center Groningen, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Alli Gokeler
- Center for Human Movement Science, University Medical Center Groningen, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands
| |
Collapse
|
14
|
Kay J, Naji L, de SA D, Simunovic N, Peterson D, Samuelsson K, Musahl V, Ayeni OR. Graft choice has no significant influence on the rate of return to sport at the preinjury level after revision anterior cruciate ligament reconstruction: a systematic review and meta-analysis. J ISAKOS 2017. [DOI: 10.1136/jisakos-2016-000113] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
15
|
Locke RC, Abraham AC, Killian ML. Orthopedic Interface Repair Strategies Based on Native Structural and Mechanical Features of the Multiscale Enthesis. ACS Biomater Sci Eng 2016; 3:2633-2643. [PMID: 32832593 DOI: 10.1021/acsbiomaterials.6b00599] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The enthesis is an organ that connects a soft, aligned tissue (tendon/ligament) to a hard, amorphous tissue (bone) via a fibrocartilage interface. Mechanically, the enthesis sustains a dynamic loading environment that includes tensile, compressive, and shear forces. The structural components of the enthesis act to minimize stress concentrations and control stretch at the interface. Current surgical repair of the enthesis, such as in rotator cuff repair and anterior cruciate ligament reconstruction, aim to bridge the gap between the injured ends via reattachment of soft-to-hard tissues or graft replacement. In this review, we discuss the multiscale, morphological, and mechanical characteristics of the fibrocartilage attachment. Additionally, we review historical and recent clinical approaches to treating enthesis injury. Lastly, we explore new technological advancements in tissue-engineered biomaterials that have shown promise in preclinical studies.
Collapse
Affiliation(s)
- Ryan C Locke
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716, United States
| | - Adam C Abraham
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, New York 10032, United States
| | - Megan L Killian
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716, United States
| |
Collapse
|