1
|
Li R, Wu Z, Chen S, Li X, Wan Q, Xie G, Pei X. Biomechanical behavior analysis of four types of short implants with different placement depths using the finite element method. J Prosthet Dent 2023; 129:447.e1-447.e10. [PMID: 36737356 DOI: 10.1016/j.prosdent.2023.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 12/31/2022] [Accepted: 01/03/2023] [Indexed: 02/04/2023]
Abstract
STATEMENT OF PROBLEM The clinical application of short implants has been increasing. However, studies on the marginal bone loss of short implants are sparse, and clinicians often choose short implants based on their own experience rather than on scientific information. PURPOSE The purpose of this finite element analysis study was to evaluate the microstrain-stress distribution in the peri-implant bone and implant components for 4 types of short implants at different placement depths of platform switching. MATERIAL AND METHODS By using short implants as prototypes, 4 short implant models were 1:1 modeled. The diameter and length of the implants were 5×5, 5×6, 6×5, and 6×6 mm. The restoration was identical for all implants. Three different depths of implant platform switching were set: equicrestal, 0.5-mm subcrestal, and 1-mm subcrestal. The models were then assembled and assigned an occlusal force of 200 N (vertical or 30-degree oblique). A finite element analysis was carried out to evaluate the maximum equivalent elastic strain and von Mises stress in the bone and the stress distribution in the implant components. RESULTS The 5×5 implant group showed the largest intraosseous strain (21.921×103 με). A 1-mm increase in implant diameter resulted in a 17.1% to 37.4% reduction in maximum intraosseous strain when loaded with oblique forces. The strain in the bone tended to be much smaller than the placement depth at the equicrestal and 0.5-mm subcrestal positions than that at the 1-mm subcrestal position, especially under oblique force loading, with an increase of approximately 37.4% to 81.8%. In addition, when the cortical bone thickness was less than 4 mm, 5×6 implants caused significantly higher intraosseous stresses than 6×6 implants. CONCLUSIONS Large implant diameters, rather than long implants, led to reduced intraosseous strain, especially under oblique loading. Regarding the implant platform switching depth, the short implant showed small intraosseous strains when the platform switching depth was equicrestal or 0.5-mm subcrestal.
Collapse
Affiliation(s)
- Ruyi Li
- Graduate student, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Zhanglin Wu
- Graduate student, State Key Laboratory of Hydraulics and Mountain River Engineering, College of Water Resource & Hydropower, Sichuan University, Chengdu, PR China
| | - Song Chen
- Resident, Stomaological Hospital of Chongqing Medical University, Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, PR China
| | - Xiang Li
- Undergraduate student, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Qianbing Wan
- Professor, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Guo Xie
- Associate Professor, State Key Laboratory of Hydraulics and Mountain River Engineering, College of Water Resource & Hydropower, Sichuan University, Chengdu, PR China
| | - Xibo Pei
- Associate Professor, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
| |
Collapse
|
2
|
Bianchi S, Mancini L, Torge D, Cristiano L, Mattei A, Varvara G, Macchiarelli G, Marchetti E, Bernardi S. Bio-Morphological Reaction of Human Periodontal Ligament Fibroblasts to Different Types of Dentinal Derivates: In Vitro Study. Int J Mol Sci 2021; 22:ijms22168681. [PMID: 34445386 PMCID: PMC8395407 DOI: 10.3390/ijms22168681] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 08/09/2021] [Accepted: 08/10/2021] [Indexed: 12/15/2022] Open
Abstract
Understanding the biological and morphological reactions of human cells towards different dentinal derivate grafting materials is fundamental for choosing the type of dentin for specific clinical situations. This study aimed to evaluate human periodontal ligament fibroblasts (hPLF) cells exposed to different dentinal derivates particles. The study design included the in vitro evaluation of mineralized dentine (SG), deproteinized and demineralized dentine (DDP), and demineralized dentine (TT) as test materials and of deproteinized bovine bone (BIOS) as the positive control material. The materials were kept with the hPLF cell line, and the evaluations were made after 24 h, 72 h, and 7 days of in vitro culture. The evaluated outcomes were proliferation by using XTT assays, the morphological characteristics by light microscopy (LM) and by the use of scanning electron microscopy (SEM), and adhesion by using confocal microscopy (CLSM). Overall, the experimental materials induced a positive response of the hPLFs in terms of proliferation and adhesion. The XTT assay showed the TT, and the SG induced significant growth compared to the negative control at 7 days follow-up. The morphological data supported the XTT assay: the LM observations showed the presence of densely packed cells with a modified shape; the SEM observations allowed the assessment of how fibroblasts exposed to DDP and TT presented cytoplasmatic extensions; and SG and BIOS also presented the thickening of the cellular membrane. The CLMS observations showed the expression of the proliferative marker, as well as and the expression of cytoskeletal elements involved in the adhesion process. In particular, the vinculin and integrin signals were stronger at 72 h, while the actin signal remained constantly expressed in all the follow-up of the sample exposed to SG material. The integrin signal was stronger at 72 h, and the vinculin and actin signals were stronger at 7 days follow-up in the sample exposed to DDP material. The vinculin and integrin signals were stronger at 72 h follow-up in the sample exposed to TT material; vinculin and integrin signals appear stronger at 24 h follow-up in the sample exposed to BIOS material. These data confirmed how dentinal derivates present satisfying biocompatibility and high conductivity and inductivity properties fundamental in the regenerative processes. Furthermore, the knowledge of the effects of the dentin’s degree of mineralization on cellular behavior will help clinicians choose the type of dentine derivates material according to the required clinical situation.
Collapse
Affiliation(s)
- Serena Bianchi
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
| | - Leonardo Mancini
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
| | - Diana Torge
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
| | - Loredana Cristiano
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
| | - Antonella Mattei
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
| | - Giuseppe Varvara
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti—Pescara ‘Gabriele d’Annunzio’, via dei Vestini 11, 66100 Chieti, Italy
- Correspondence:
| | - Guido Macchiarelli
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
| | - Enrico Marchetti
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
| | - Sara Bernardi
- Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (S.B.); (L.M.); (D.T.); (L.C.); (A.M.); (G.M.); (E.M.); (S.B.)
- Center of Microscopy, University of L’Aquila, 67100 L’Aquila, Italy
| |
Collapse
|
3
|
Ultrashort Implants, Alternative Prosthetic Rehabilitation in Mandibular Atrophies in Fragile Subjects: A Retrospective Study. Healthcare (Basel) 2021; 9:healthcare9020175. [PMID: 33562102 PMCID: PMC7914866 DOI: 10.3390/healthcare9020175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/31/2021] [Accepted: 02/03/2021] [Indexed: 12/13/2022] Open
Abstract
This study aimed to evaluate the effectiveness of using ultrashort implants in the rehabilitation of jaws of fragile patients. The aim of the study was to retrospectively evaluate the survival rate of full-arch prosthetic rehabilitation on ultrashort implants, length 4 mm, 4 mm in diameter in the premolar and canine area and 4.5 mm in diameter in the molar area, with the insertion torque of 60 Nw and immediate loading. Nineteen patients were evaluated for 3 years clinically and radiographically. The significant majority of the patients at the 3 year follow-up (T4) presented a stable and functional implant-supported prothesis, and the survival rate of the implants was 85%, with a loss of 16 implants on 114 implants. The combination of the innovative implant surfaces and the correct project of the prostheses, with the related implant connection, determined a different timing in the therapy, allowing to obtain an immediate loading, which is currently demanded by patients. This and recent reports on short and ultrashort implant usage in atrophic jaws offer a good solution in critical cases. In conclusion, within the limits of the study, the full-arch rehabilitation with immediate loading on ultrashort implants showed good results with few postoperative complications and related low biological cost.
Collapse
|
4
|
Schimmel M, Janner SFM, Joda T, Wittneben JG, McKenna G, Brägger U. Mandibular implant-supported fixed complete dental prostheses on implants with ultrashort and standard length: A pilot treatment. J Prosthet Dent 2020; 126:137-143. [PMID: 32736866 DOI: 10.1016/j.prosdent.2020.04.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 04/17/2020] [Accepted: 04/17/2020] [Indexed: 11/18/2022]
Abstract
Edentulous patients may be restored with complete-arch implant-supported fixed complete dental prostheses (IFCDPs) on angled distal implants or on parallel implants distributed equally across the mandible to increase the area of support. A treatment is presented to introduce the clinical concept of providing edentulous patients with an implant-supported fixed complete dental prosthesison parallel tissue-level implants in the mandible with standard length implants interforaminally and ultrashort implants distally. A structured prosthetic approach was used for the tooth arrangement with a modified workflow as per the Biofunctional Prosthetic System adapted for static computer-aided implant surgery (s-CAIS) and computer-aided design and computer-aided manufacturing (CAD-CAM) of the screw-retained implant-supported fixed complete dental prosthesis. The concept offered advantages in challenging anatomic, surgical, and prosthetic conditions; providing distal nonangled abutments and implant platforms, which were straightforward to clean. If necessary, the prosthesis could have been easily converted into a removable overdenture using the existing digital prosthetic arrangement. Should implant removal be required, the extrashort implants can be removed with minimal surgical risk or morbidity.
Collapse
Affiliation(s)
- Martin Schimmel
- Full Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Simone F M Janner
- Senior Lecturer, Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Tim Joda
- Associate Professor, Department of Reconstructive Dentistry, University Center for Dental Medicine, Basel, Switzerland
| | - Julia G Wittneben
- Senior Lecturer, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Gerald McKenna
- Senior Lecturer, Centre for Public Health, Institute of Clinical Sciences Block B, Queens University Belfast, Belfast, United Kingdom
| | - Urs Brägger
- Full Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
5
|
Bianchi S, Fantozzi G, Bernardi S, Antonouli S, Continenza MA, Macchiarelli G. Commercial oral hygiene products and implant collar surfaces: Scanning electron microscopy observations. CANADIAN JOURNAL OF DENTAL HYGIENE : CJDH = JOURNAL CANADIEN DE L'HYGIENE DENTAIRE : JCHD 2020; 54:26-31. [PMID: 33240361 PMCID: PMC7533810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Revised: 04/03/2019] [Accepted: 01/10/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND The use of medicated mouthwashes and gels in the home care maintenance of dental implants is controversial due to the possibility of residue deposition on the implant collar. The aim of this in vitro study was to analyse, by means of scanning electron microscopy (SEM), the amount of residues on dental implant collars treated with various commercial home dental care products. METHODS Gel and mouthwash products were tested on 10 implants. The gels included sodium fluoride, amine fluoride, and sodium hyaluronate products. The mouthwashes tested contained triclosan, nimesulide, stannous fluoride, amine fluoride, and hexetidine-chlorobutanol. The SEM observations were performed at different magnifications in double modality SE (secondary electrons) and BSE (backscattered electrons) to qualitatively assess any residual products. The image quantitative analysis was performed by Image J® software to assess areas occupied by residuals. All results were analysed by the same researcher with experience in electron microscopy. RESULTS The fluoride-based gel products left wider areas occupied by residuals than the mouthwash products. In particular the fluoride-based and hyaluronate products left the highest amount of residues. Among mouthwashes, fluoride-based and triclosan products showed the highest amount of residuals deposition. DISCUSSION Oral hygiene procedures and related professional products are fundamental to the prevention, treatment, and control of microorganisms. In the case of implants, mechanical and chemical plaque control strategies are even more important since the potentially harmful biofilm covers abiotic titanium surfaces. In situ fixture maintenance is crucial for dental implant therapy success. Correct recommendation of home care products for bacterial control is fundamental to the health of implants and their surrounding tissues. CONCLUSIONS Data from this experimental study showed that home care commercial products in gel formulation, especially those containing fluoride, leave more residuals on titanium smooth surfaces than mouthwash products. The longer permanence of the products may lead to a more effective plaque control than other products.
Collapse
Affiliation(s)
- Serena Bianchi
- Department of Life, Health and Environmental Sciences, University of L’Aquila, Italy
| | | | - Sara Bernardi
- Department of Life, Health and Environmental Sciences, University of L’Aquila, Italy
| | - Sevastiani Antonouli
- Doctoral student (2nd year), Department of Life, Health and Environmental Sciences, University of L’Aquila, Italy
| | | | - Guido Macchiarelli
- Department of Life, Health and Environmental Sciences, University of L’Aquila, Italy
| |
Collapse
|
6
|
Influence of Different Repair Acrylic Resin and Thermocycling on the Flexural Strength of Denture Base Resin. ACTA ACUST UNITED AC 2020; 56:medicina56020050. [PMID: 31973219 PMCID: PMC7074266 DOI: 10.3390/medicina56020050] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 01/12/2020] [Accepted: 01/15/2020] [Indexed: 11/16/2022]
Abstract
Background and Objectives: Fractured acrylic denture base is a common occurrence in clinical practice. The effective denture repair procedure is cost-effective, time conserving, and results in lesser time without denture for the patient. Along with various reinforcements and surface modifications; different acrylic resins are investigated in improving the flexural strength of the fractured site. The aim of this study was to evaluate the flexural strength of a polymethyl methacrylate (PMMA) denture base repaired with heat-polymerized (HPA), auto-polymerized (APA) and light-polymerized acrylic (LPA) resins after thermocycling. Materials and Methods: Forty rectangular shaped (50 mm × 25 mm × 3 mm) PMMA specimens were fabricated. Group 1 specimens (n = 10) were kept as controls and the remaining 30 samples were sectioned at the center with a repair site dimension of 3 mm. The samples from three groups (n = 10) were repaired with HPA, APA, and LPA resins, respectively. The specimens were thermocycled for 5000 cycles and subjected to a three-point flexural test. The maximum load required to fracture the specimens was recorded, and further analyzed with ANOVA and the Games-Howell Post hoc test at the significance level p = 0.05. Results: The average maximum load and flexural strength of the control group was 173.60 N and 13.02 Mpa and corresponding values for denture repaired with HPA was 87.36 N and 6.55 Mpa. The corresponding values for APA resin and LPA resins were 62.94 N, 57.51 N, and 4.72 Mpa, 4.06 Mpa, respectively. Conclusions: The PMMA specimens repaired with HPA resins resulted in a significantly higher load to fracture compared to APA resin and LPA resin.
Collapse
|
7
|
In Vitro Evaluation of Bacterial Adhesion and Bacterial Viability of Streptococcus mutans, Streptococcus sanguinis, and Porphyromonas gingivalis on the Abutment Surface of Titanium and Zirconium Dental Implants. Int J Dent 2019; 2019:4292976. [PMID: 31312218 PMCID: PMC6595387 DOI: 10.1155/2019/4292976] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 05/25/2019] [Accepted: 05/28/2019] [Indexed: 12/14/2022] Open
Abstract
Objective To evaluate the in vitro adherence and viability of 3 bacterial species Streptococcus mutans (ATCC 25175), Streptococcus sanguinis (ATCC 10556), and Porphyromonas gingivalis (ATCC 33277) on the surfaces of dental implants of titanium, zirconium, and their respective fixing screws. Methods Two analysis groups were formed: group 1 with 3 titanium pillars and group 2 with 3 zirconium pillars, each with their respective fixing screws. Each of these groups was included in tubes with bacterial cultures of Streptococcus mutans (ATCC 25175), Streptococcus sanguinis (ATCC 10556), and Porphyromonas gingivalis (ATCC 33277). These samples were incubated at 37°C under anaerobic conditions. Bacterial adherence was assessed by measurement of the change in colony-forming units (CFU), and bacterial viability was evaluated with the colorimetric test of 3-(4,5-dimethylthiazol-2)-2,5 diphenyl tetrazolium bromide (MTT). Results The bacterial adhesion in the titanium abutments was higher for Streptococcus mutans (190.90 CFU/mL), and the viability was greater in Porphyromonas gingivalis (73.22%). The zirconium abutment group showed the highest adherence with Streptococcus mutans (331.82 CFU/mL) and the highest bacterial viability with the S. sanguinis strain (38.42%). The titanium fixation screws showed the highest adhesion with S. sanguinis (132.5 CFU/mL) compared to the zirconium fixation screws where S. mutans had the highest adhesion (145.5 CFU/mL). The bacterial viability of S. mutans was greater both in the titanium fixation screws and in the zirconium fixation screws 78.04% and 57.38%, respectively. Conclusions Our results indicate that there is in vitro bacterial adherence and viability in both titanium abutments and zirconium abutments and fixation screws for both. Streptococcus mutans is the microorganism that shows the greatest adherence to the surfaces of both titanium and zirconium and the fixing screws of the latter. On the contrary, bacterial viability is greater on the titanium abutments with P. gingivalis than on the zirconium abutments with S. sanguinis. With respect to the fixation screws, in both cases, the viability of S. mutans was greater with respect to the other bacteria. In general, the titanium abutments showed less adherence but greater bacterial viability.
Collapse
|
8
|
Microbiological and SEM-EDS Evaluation of Titanium Surfaces Exposed to Periodontal Gel: In Vitro Study. MATERIALS 2019; 12:ma12091448. [PMID: 31060232 PMCID: PMC6539618 DOI: 10.3390/ma12091448] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 04/29/2019] [Accepted: 05/01/2019] [Indexed: 12/13/2022]
Abstract
Inflammatory diseases affecting the soft and hard tissues surrounding an implant represent a new challenge in contemporary implant dentistry. Among several methods proposed for the decontamination of titanium surfaces, the administration of topical 14% doxycycline gel seems to be a reliable option. In the present study, we evaluated the microbial effect of 14% doxycycline gel applied on titanium surfaces and exposed to human salivary microbes in anaerobic conditions. We also examined the composition of the exposed surfaces to assess the safe use of periodontal gel on titanium surfaces. Six anatase and six type 5 alloy titanium surfaces were used and divided into two groups: The test group and the positive control group. Both were cultured with human salivary samples in anaerobic conditions. On the test groups, 240 mg of periodontal gel was applied. The microbial assessment was performed with a colony-forming unit (CFU) count and matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) to identify the species. The surface integrity was assessed using scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDS). The results demonstrated the microbial efficacy of the 14% doxycycline periodontal gel and its safe use on titanium surfaces. However, the SEM observations revealed the permanence of the gel on the titanium surfaces due to the physical composition of the gel. This permanence needs to be further investigated in vivo and a final polishing protocol on the titanium surface is recommended.
Collapse
|