1
|
García-Rueda L, Cabanas-Valdés R, Salgueiro C, Pérez-Bellmunt A, Rodríguez-Sanz J, López-de-Celis C. Immediate effects of TECAR therapy on lower limb to decrease hypertonia in chronic stroke survivors: a randomized controlled trial. Disabil Rehabil 2024:1-10. [PMID: 38958103 DOI: 10.1080/09638288.2024.2365992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 06/05/2024] [Indexed: 07/04/2024]
Abstract
PURPOSE To analyze immediate effects of TECAR therapy (TT) to reduce lower limb hypertonia and improve functionality in chronic post-stroke. MATERIALS AND METHODS It is a single-blind randomized controlled clinical trial. A total of 36 chronic stroke survivors were divided into two groups. The experimental group received a single 30-minute session of TT with functional massage (FM) on lower limb. The control group received a single 30-minute session sham treatment of TT plus FM. The primary outcome measure was hypertonia (Modified Ashworth Scale, MAS). Secondary outcomes were gait speed (4-Meter Walk-Test), standing knee-flexion (Fugl-Meyer Assessment Scale IV-item), change in weight bearing ankle dorsiflexion (Ankle Lunge Test, ALT), and functional lower limb strength (5-Times Sit-to-Stand Test). All measurements were performed at baseline, immediately and 30-minutes after treatment. RESULTS There was a group-time interaction in MAS-knee (p = 0.044), MAS-ankle (p = 0.018) and ALT (p = 0.016) between T1 and T0 (p<.0001) and T2 and T0 (p<.0001) for the experimental group. There was a significant increase in ALT between T1 and T0 (p = 0.003) in the control group. CONCLUSIONS A single session of TT performed at the same time as FM immediately reduces plantar-flexors and knee-extensor muscle hypertonia and increases change in weight bearing ankle dorsiflexion in chronic stroke survivors.
Collapse
Affiliation(s)
| | - Rosa Cabanas-Valdés
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Carina Salgueiro
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, Barcelona, Spain
- Clínica de Neurorehabilitación, Barcelona, Spain
| | - Albert Pérez-Bellmunt
- Basic Sciences Department, Actium Functional Anatomy Research Group, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Jacobo Rodríguez-Sanz
- Basic Sciences Department, Actium Functional Anatomy Research Group, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Carlos López-de-Celis
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, Barcelona, Spain
- Fundació Institut Universitari per a la recerca a l'Atenció Primària de Salut Jordi Gol i Gurina (IDIAPJGol), Barcelona, Spain
| |
Collapse
|
2
|
Zhang T, Yan HX, An Y, Yin L, Sun PP, Zhao JN, Yan JT. The Efficacy and Safety of Manual Therapy for Symptoms Associated with Multiple Sclerosis: A Systematic Review and Meta-Analysis. JOURNAL OF INTEGRATIVE AND COMPLEMENTARY MEDICINE 2022; 28:780-790. [PMID: 36206232 PMCID: PMC9595630 DOI: 10.1089/jicm.2021.0382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Background: Multiple sclerosis (MS) is a chronic neurological autoimmune disease, affecting the psychological and physical health of patients. Manual therapies have been proven to relieve pain, strengthen muscles, and improve bladder and bowel problems with a high safety and low adverse event profile. Previous studies have reported the results of manual therapy in alleviating symptoms associated with MS, but the conclusions were controversial. Objective: The purpose of this meta-analysis is to comprehensively analyze and determine the efficacy and safety of manual therapy in relieving symptoms associated with MS. Methods: Eight electronic databases were searched from inception of the database to April 30, 2021. Randomized controlled trials (RCTs) using manual therapy in patients to relieve symptoms associated with MS were considered eligible for this study. Two reviewers independently extracted data using pre-established standards. Results: Finally, 10 eligible RCTs with 631 subjects were included in this meta-analysis. These data establish that massage therapy can significantly ameliorate fatigue, pain, and spasms, while reflexology was only effective in relieving pain in MS patients. No adverse events were reported in eligible RCTs. Conclusions: The present study provides strong evidence that massage therapy could alleviate fatigue, pain, and spasms in MS patients, while reflexology plays a positive role in relieving pain. Physicians could consider massage therapy or reflexology as a safe and effective complementary and alternative treatment. Larger RCTs with higher methodological quality are needed in the future, which aim to provide more meaningful evidence for further proof of efficacy.
Collapse
Affiliation(s)
- Tao Zhang
- Department of Tuina, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Hongkou, Shanghai, China
| | - Hui-Xin Yan
- Department of Tuina, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Hongkou, Shanghai, China
| | - Yun An
- Department of Tuina, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Hongkou, Shanghai, China
| | - Lu Yin
- Department of Rehabilitation, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Hongkou, Shanghai, China
| | - Ping-Ping Sun
- School of Rehabilitation Science, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Jiang-Na Zhao
- Department of Tuina, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Hongkou, Shanghai, China
| | - Jun-Tao Yan
- Department of Tuina, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Hongkou, Shanghai, China.,Address correspondence to: Jun-Tao Yan, BM, Department of Tuina, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, No. 110 Ganhe Road, Hongkou, Shanghai 200437, China
| |
Collapse
|
3
|
Bhattacharjee A, Chien SYP, Anwar S, Loghmani MT. Quantifiable Soft Tissue Manipulation (QSTM™) - A novel modality to improve clinical manual therapy with objective metrics. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:4961-4964. [PMID: 34892321 DOI: 10.1109/embc46164.2021.9629616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Soft Tissue Manipulation (STM), a form of mechanotherapy, offers a clinical modality to examine and treat Neuromusculoskeletal (NMS) pain disorders and dysfunction. The, current STM practice is mostly subjective and reliant on anecdotal patient feedback and lacks quantification with objective metrics. This paper proposes Quantifiable Soft Tissue Manipulation (QSTM™), a sensor based computerized technological advancement in Soft tissue examination and treatment enabling new standard of practice in manual therapy. This novel medical device technology aims to produce optimum STM prescriptions using ergonomic, portable, handheld medical tools with specially contoured tips designed to palpate and assess tissue anomalies of specific musculoskeletal conditions. QSTM™ captures three-dimensional forces and motion of the mechatronic handheld tools to quantify STM treatment parameters, such as (resultant force, force application angle, rate, direction, and treatment time). Clinical practice using QSTM™ facilitates real-time visual feedback of treatment metrics and subsequent treatment documentation for comparison and analysis on a Windows based computer software (Q-Ware©). Pre-clinical testing using the QSTM™ medical device system clearly identifies inconsistencies among practitioners and distinguishes STM practice variabilities. Thus, QSTM™ is an apt tool for soft tissue treatment assessment, analysis, and individualized prescriptions for targeted STM dosing and commercialization.
Collapse
|
4
|
Cabanas-Valdés R, Calvo-Sanz J, Serra-Llobet P, Alcoba-Kait J, González-Rueda V, Rodríguez-Rubio PR. The Effectiveness of Massage Therapy for Improving Sequelae in Post-Stroke Survivors. A Systematic Review and Meta-Analysis. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18094424. [PMID: 33919371 PMCID: PMC8122530 DOI: 10.3390/ijerph18094424] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 04/17/2021] [Accepted: 04/19/2021] [Indexed: 12/26/2022]
Abstract
Objective: To assess the effect of therapeutic massage for improving sequelae in stroke survivors. Methods: A systematic review of the nine medical databases from January 1961 to December 2020 was carried out. The bibliography was screened to identify randomized controlled clinical trials (RCTs). Two reviewers independently screened references, selected relevant studies, extracted data and assessed the risk of bias using the PEDro scale. The primary outcome was upper and lower limb motor function and spasticity. Results: A total of 3196 studies were identified and 18 RCT were finally included (1989 individuals). A meta-analysis of RCTs in the comparison of Chinese massage (Tuina) plus conventional physiotherapy versus conventional physiotherapy was performed. The mean difference (MD) in the subacute stage on upper limb motor-function using the Fugl Meyer Assessment was 2.75; (95% confidence interval (CI) from 0.97 to 4.53, p = 0.002, I2 = 36%). The MD on upper limb spasticity using modified Ashworth scale was −0.15; (95% CI from −0.24 to −0.06, p < 0.02, I2 = 0%).The MD on lower limb spasticity was −0.59; (95% CI from −0.78 to −0.40, p < 0.001, I2 = 0%) in the endpoint. Conclusions: Therapeutic massage, especially Tuina, in addition to conventional therapy is effective for improving motor function and for reducing spasticity in stroke survivors.
Collapse
Affiliation(s)
- Rosa Cabanas-Valdés
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, 08195 Barcelona, Spain; (P.S.-L.); (J.A.-K.); (V.G.-R.); (P.R.R.-R.)
- Correspondence:
| | - Jordi Calvo-Sanz
- Physiotherapy Department, School of Health Sciences, Tecno Campus, Mataró-Pompeu Fabra University (TCM-UPF), 08302 Barcelona, Spain;
- Hospital Asepeyo Sant Cugat del Vallès, 08174 Barcelona, Spain
| | - Pol Serra-Llobet
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, 08195 Barcelona, Spain; (P.S.-L.); (J.A.-K.); (V.G.-R.); (P.R.R.-R.)
| | - Joana Alcoba-Kait
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, 08195 Barcelona, Spain; (P.S.-L.); (J.A.-K.); (V.G.-R.); (P.R.R.-R.)
- CENAC, 08028 Barcelona, Spain
| | - Vanessa González-Rueda
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, 08195 Barcelona, Spain; (P.S.-L.); (J.A.-K.); (V.G.-R.); (P.R.R.-R.)
- Fundació Institut Universitari per a la Recerca a l’Atenció Primaria de Salut Jordi Gol i Gurina, 08007 Barcelona, Spain
| | - Pere Ramón Rodríguez-Rubio
- Physiotherapy Department, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, 08195 Barcelona, Spain; (P.S.-L.); (J.A.-K.); (V.G.-R.); (P.R.R.-R.)
| |
Collapse
|
5
|
Everingham JB, Martin PT, Lujan TJ. A Hand-Held Device to Apply Instrument-Assisted Soft Tissue Mobilization at Targeted Compression Forces and Stroke Frequencies. J Med Device 2019; 13:0145041-145045. [PMID: 30662581 PMCID: PMC6298531 DOI: 10.1115/1.4041696] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 10/03/2018] [Indexed: 11/08/2022] Open
Abstract
Instrument-assisted soft tissue mobilization (IASTM) is a manual therapy technique that is commonly used to treat dysfunctions in ligaments and other musculoskeletal tissues. The objective of this study was to develop a simple hand-held device that helps users accurately apply targeted compressive forces and stroke frequencies during IASTM treatments. This portable device uses a force sensor, tablet computer, and custom software to guide the application of user-specified loading parameters. To measure performance, the device was used to apply a combination of targeted forces and stroke frequencies to foam blocks and silicone pads. Three operators using the device applied targeted forces between 0.3 and 125 N with less than 10% error and applied targeted stroke frequencies between 0.25 and 1.0 Hz with less than 3% error. The mean error in applying targeted forces increased significantly at compressive forces less than 0.2 N and greater than 125 N. For experimental validation, the device was used to apply a series of IASTM treatments over three-weeks to rodents with a ligament injury, and the targeted compressive force and stroke frequency were repeatedly applied with an average error less than 5%. This validated device can be used to investigate the effect of IASTM loading parameters on tissue healing in animal and human studies, and therefore can support the optimization and adoption of IASTM protocols that improve patient outcomes.
Collapse
Affiliation(s)
- John B Everingham
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID 83725-2085
| | - Peter T Martin
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID 83725-2085
| | - Trevor J Lujan
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID 83725-2085 e-mail:
| |
Collapse
|
6
|
Alotaibi AM, Anwar S, Terry Loghmani M, Chien S. Force Sensing for an Instrument-Assisted Soft Tissue Manipulation Device. J Med Device 2017. [DOI: 10.1115/1.4036654] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Instrument-assisted soft tissue manipulation (IASTM) is a form of mechanotherapy, e.g., massage, that uses rigid devices which may be machined or cast. The delivered force, which is a critical parameter during IASTM, is not measured and not standardized in current clinical IASTM practice. In addition to the force, the angle of treatment and stroke frequency play an important role during IASTM. For accurate IASTM treatment, there is a strong need to scientifically characterize the IASTM delivered force, angle of treatment, and stroke frequency. This paper presents a novel, mechatronic design of an IASTM device that can measure the localized pressure on the soft tissue in a clinical treatment. The proposed design uses a three-dimensional (3D) load cell, which can measure all three-dimensional force components simultaneously. The device design was implemented using an IMUduino microcontroller board which provides tool orientation angles. These orientation angles were used for coordinate transformation of the measured forces to the tool–skin interface. Additionally, the measured force value was used to compute the stroke frequency. This mechatronic IASTM tool was validated for force measurements in the direction of tool longitudinal axis using an electronic plate scale that provided the baseline force values to compare with the applied force values measured by the tool. The load cell measurements and the scale readings were found to agree within the expected degree of accuracy.
Collapse
Affiliation(s)
- Ahmed M. Alotaibi
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907 e-mail:
| | - Sohel Anwar
- Mem. ASME Department of Mechanical Engineering, IUPUI, Indianapolis, IN 46202 e-mail:
| | - M. Terry Loghmani
- School of Health and Rehabilitation Sciences, IUPUI, Indianapolis, IN 46202 e-mail:
| | - Stanley Chien
- Department of Electrical and Computer Engineering, IUPUI, Indianapolis, IN 46202 e-mail:
| |
Collapse
|
7
|
Best TM, Crawford SK, Haas C, Charles L, Zhao Y. Transverse forces in skeletal muscle with massage-like loading in a rabbit model. Altern Ther Health Med 2014; 14:393. [PMID: 25310893 PMCID: PMC4200125 DOI: 10.1186/1472-6882-14-393] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2013] [Accepted: 10/07/2014] [Indexed: 11/21/2022]
Abstract
Background The objective of this study was to quantify the transverse forces in skeletal muscle subjected to constant compressive massage-like loading (MLL) following eccentric exercise (ECC). Methods Twenty-eight New Zealand White rabbits were used for this two-part study. For all testing, a customized electromechanical device was utilized to apply a constant compressive force MLL to the tibialis anterior (TA) muscle and the resultant transverse forces were quantified. The device consisted of two stepper motors that were positioned orthogonally to each other and connected to separate sliding tracks. A stainless steel cylindrical massage tip was mounted to a customized two-axis sensor consisting of two strain gauges with which forces along the two axes were measured. First, we determined the effects of tissue loading frequency and compression magnitude on transverse forces in the TA. Following a bout of ECC, sixteen rabbits were randomly assigned to a protocol with MLL frequency of 0.25 Hz or 0.5 Hz at a constant compressive force of 5 N or 10 N. Secondly, we utilized a protocol of 0.5 Hz, 10 N, 15 min MLL that was performed on 4 consecutive days commencing immediately post ECC (n = 6 animals) or 48 hours following ECC (n = 6 animals). Transverse forces were measured during all 4 MLL sessions for the entire 15 min duration for both the immediate and the delayed groups. Results Both frequency and magnitude of compressive force due to MLL showed an effect on the magnitude of transverse force (p < 0.05 for each parameter). Furthermore, MLL beginning immediately following ECC produced higher transverse forces than MLL delayed by 48 hours with an average 20% difference between the two MLL groups over the four day protocol. Forces were higher in the middle 5 minutes compared to the first 5 minutes for all MLL bouts in both groups. Conclusions Frequency and magnitude of MLL and timing for delivery of MLL following ECC affect resultant transverse force values for exercised muscle. The application of our findings to humans receiving massage following exercise remains unknown at this time.
Collapse
|
8
|
Haas C, Butterfield TA, Abshire S, Zhao Y, Zhang X, Jarjoura D, Best TM. Massage timing affects postexercise muscle recovery and inflammation in a rabbit model. Med Sci Sports Exerc 2014; 45:1105-12. [PMID: 23274593 DOI: 10.1249/mss.0b013e31827fdf18] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
PURPOSE This study compared the effect of immediate versus delayed massage-like compressive loading (MLL) on peak isometric torque recovery and inflammatory cell infiltration after eccentric exercise (EEX). METHODS Eighteen skeletally mature New Zealand White rabbits were instrumented with peroneal nerve cuffs for the stimulation of hindlimb tibialis anterior muscles. After a bout of EEX, rabbits were randomly assigned to an MLL protocol (0.5 Hz, 10 N, 15 min) that started immediately post-EEX, 48 h post-EXX, or no-MLL control and performed for four consecutive days. A torque-angle (T-Θ) relationship was obtained for 21 joint angles pre- and post-EEX and after four consecutive days of MLL or no-MLL. Muscle wet weights and immunohistochemical sections were obtained after final treatments. RESULTS EEX produced an average 51% ± 13% decrease in peak isometric torque output. The greatest peak torque recovery occurred with the immediate application of MLL. There were differences in torque recovery between immediate and delayed MLL (P = 0.0012), immediate MLL and control (P < 0.0001), and delayed MLL and control (P = 0.025). Immunohistochemical analysis showed 39.3% and 366.0% differences in the number of RPN3/57 and CD11b-positive cells between immediate (P = 0.71) and delayed MLL (P = 0.12). The area under the T-Θ curve showed a difference for immediate (P < 0.0001) and delayed (P = 0.0051) MLL as compared with control. Exercise produced an average 10° ± 0.2° rightward shift from preexercise peak isometric torque angle. Control, immediate MLL, and delayed MLL produced an average leftward angular shift from the postexercise angle (P = 0.28, P = 0.03, and P = 0.47, respectively). CONCLUSION Post-EEX, immediate MLL was more beneficial than delayed MLL in restoring muscle function and in modulating inflammatory cell infiltration. These findings invite similar human studies to make definitive conclusions on optimal timing of massage-based therapies.
Collapse
Affiliation(s)
- Caroline Haas
- Division of Sports Medicine, Department of Family Medicine, The Ohio State University, Columbus, OH 43221, USA
| | | | | | | | | | | | | |
Collapse
|
9
|
Wang Q, Zeng H, Best TM, Haas C, Heffner NT, Agarwal S, Zhao Y. A mechatronic system for quantitative application and assessment of massage-like actions in small animals. Ann Biomed Eng 2013; 42:36-49. [PMID: 23943071 DOI: 10.1007/s10439-013-0886-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2013] [Accepted: 08/01/2013] [Indexed: 10/26/2022]
Abstract
Massage therapy has a long history and has been widely believed effective in restoring tissue function, relieving pain and stress, and promoting overall well-being. However, the application of massage-like actions and the efficacy of massage are largely based on anecdotal experiences that are difficult to define and measure. This leads to a somewhat limited evidence-based interface of massage therapy with modern medicine. In this study, we introduce a mechatronic device that delivers highly reproducible massage-like mechanical loads to the hind limbs of small animals (rats and rabbits), where various massage-like actions are quantified by the loading parameters (magnitude, frequency and duration) of the compressive and transverse forces on the subject tissues. The effect of massage is measured by the difference in passive viscoelastic properties of the subject tissues before and after mechanical loading, both obtained by the same device. Results show that this device is useful in identifying the loading parameters that are most conducive to a change in tissue mechanical properties, and can determine the range of loading parameters that result in sustained changes in tissue mechanical properties and function. This device presents the first step in our effort for quantifying the application of massage-like actions used clinically and measurement of their efficacy that can readily be combined with various quantitative measures (e.g., active mechanical properties and physiological assays) for determining the therapeutic and mechanistic effects of massage therapies.
Collapse
Affiliation(s)
- Qian Wang
- Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, OH, USA
| | | | | | | | | | | | | |
Collapse
|
10
|
Haas C, Butterfield TA, Zhao Y, Zhang X, Jarjoura D, Best TM. Dose-dependency of massage-like compressive loading on recovery of active muscle properties following eccentric exercise: rabbit study with clinical relevance. Br J Sports Med 2013; 47:83-8. [PMID: 22736207 DOI: 10.1136/bjsports-2012-091211] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND Optimal strategies for massage and its use in athletes have not been conclusively demonstrated. PURPOSE/STUDY DESIGN: Effects of varying duration, frequency and magnitude of massage-like compressive loading (MLL) on recovery of skeletal muscle active properties (torque angle (T-Θ) relationship) following exercise-induced muscle injury were studied. METHODS Twenty-four New Zealand White rabbits were surgically instrumented with bilateral peroneal nerve cuffs for stimulation of hindlimb tibialis anterior muscles. Following a bout of eccentric exercise (EEX), rabbits were randomly assigned to a MLL protocol of 0.25 or 0.5 Hz at 5 or 10 N for 15 or 30 min. T-Θ was obtained for 21 tibiotarsal joint angles pre- and post-EEX and post 4 consecutive days of MLL. Muscle wet weight and H&E sections were obtained following final treatments. RESULTS EEX produced an average 61.8%±2.1 decrease in peak isometric torque output. Differences in torque recovery were found between magnitudes (5 and 10 N; p=0.004, n=12) and frequencies (0.25 and 0.5 Hz; p=0.012, n=12), but no difference for durations (15 and 30 min) with the 0.5 Hz, 10 N, 15 min protocol showing greatest recovery 4 days post-EEX. MLL muscle (n=12) wet weight was 3.22±0.18 g, while no MLL tissue (n=9) weighed 3.74±0.22 g (p=0.029). Histological analysis showed a difference in torn fibres between low-parameter and high-parameter MLL (6.5±1.04 vs 0.5±0.29 per 0.59 mm(2), p=0.005). CONCLUSIONS Results showed a dose-response effect for magnitude and frequency of MLL on recovery of active muscle properties following EEX. Future studies will investigate underlying biological mechanisms for this enhanced recovery of muscle function.
Collapse
Affiliation(s)
- Caroline Haas
- Division of Sports Medicine, Department of Family Medicine, The Ohio State University, Columbus, Ohio 43221, USA
| | | | | | | | | | | |
Collapse
|