1
|
Abbott EM, Bhimani R, Kadakia RJ, Bariteau J, Chang YH. 3D kinematics of tibiotalar motion in patients with mobile bearing and fixed bearing total ankle arthroplasty: In vivo videofluoroscopic feasibility study. Gait Posture 2024; 111:176-181. [PMID: 38705035 DOI: 10.1016/j.gaitpost.2024.04.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 03/16/2024] [Accepted: 04/17/2024] [Indexed: 05/07/2024]
Abstract
BACKGROUND As total ankle arthroplasty (TAA) is an increasingly common surgical intervention for patients with end-stage ankle arthritis, there is a need to better understand the dynamic performance of prosthetic implants during activities of daily living. Our purpose was to quantify and compare relative tibiotalar motion during gait in persons with a fixed-bearing (FB) and mobile-bearing (MB) total ankle arthroplasty. We hypothesized a FB prosthesis would have lower tibiotalar range of motion (ROM). METHODS Patients at least 12 months postoperative with either a FB (n=5) or MB (n=3) total ankle arthroplasty were tested. We used high-speed biplanar videoradiography to quantify tibiotalar kinematics during self-selected gait. Angular and linear ROM in three axes were compared between the groups. RESULTS ROM for dorsiflexion-plantarflexion, internal-external rotation, and inversion-eversion angles in FB subjects averaged 7.47±4.05°, 7.39±3.63°, and 4.51±2.13°, respectively. ROM in MB subjects averaged 6.74±2.04°, 6.28±4.51°, and 5.68±2.81°, respectively. Linear ROM along anteroposterior, mediolateral, and superior-inferior axes in FB subjects averaged 1.47±2.07 mm, 1.13±1.49 mm, and 0.28±0.30 mm, respectively. Linear ROM in MB subjects averaged 0.68±1.44 mm, 0.60±1.41 mm, and 0.20±0.13 mm, respectively. We found no significant difference between the two groups for any of these ROM parameters (p>0.05). CONCLUSION Total ankle arthroplasty using either FB or MB design appears to confer similar ankle motion during the gait cycle in this biplanar fluoroscopic model. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
- Emily M Abbott
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA; School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Rohan Bhimani
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
| | - Rishin J Kadakia
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA
| | - Jason Bariteau
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA
| | - Young-Hui Chang
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA
| |
Collapse
|
2
|
Behling AV, Welte L, Kelly L, Rainbow MJ. Human in vivo midtarsal and subtalar joint kinematics during walking, running and hopping. J R Soc Interface 2024; 21:20240074. [PMID: 38807524 DOI: 10.1098/rsif.2024.0074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 04/08/2024] [Indexed: 05/30/2024] Open
Abstract
The interaction among joints of the midtarsal complex and subtalar joint is important for locomotor function; however, its complexity poses substantial challenges in quantifying the joints' motions. We determine the mobility of these joints across locomotion tasks and investigate the influence of individual talus morphology on their motion. Using highly accurate biplanar videoradiography, three-dimensional bone kinematics were captured during walking, running and hopping. We calculated the axis of rotation of the midtarsal complex and subtalar joint for the landing and push-off phases. A comparison was made between these rotation axes and the morphological subtalar axis. Measurement included total rotation about and the orientation of the rotation axes in the direction of the subtalar joint and its deviation via spatial angles for both phases. The rotation axes of all three bones relative to the talus closely align with the morphological subtalar axis. This suggests that the midtarsal and subtalar joints' motions might be described by one commonly oriented axis. Despite having such an axis, the location of the axes and ranges of motion differed among the bones. Our results provide a novel perspective of healthy foot function across different sagittal plane-dominant locomotion tasks underscoring the importance of quantifying midtarsal complex and subtalar motion while accounting for an individual's talus morphology.
Collapse
Affiliation(s)
- Anja-Verena Behling
- School of Human Movement and Nutrition Science, The University of Queensland , Brisbane, Queensland, Australia
- Department of Mechanical and Materials Engineering, Queen's University , Kingston, Ontario, Canada
| | - Lauren Welte
- Mechanical Engineering, University of Alberta , Edmonton, Alberta, Canada
- Biomedical Engineering, University of Alberta , Edmonton, Alberta, Canada
| | - Luke Kelly
- School of Human Movement and Nutrition Science, The University of Queensland , Brisbane, Queensland, Australia
- Griffith Centre of Biomedical & Rehabilitation Engineering, Griffith University , Gold Coast, Queensland, Australia
- School of Health Sciences & Social Work, Griffith University , Gold Coast, Queensland, Australia
| | - Michael J Rainbow
- Department of Mechanical and Materials Engineering, Queen's University , Kingston, Ontario, Canada
| |
Collapse
|
3
|
Maikos JT, Chomack JM, Herlihy DV, Paglia DN, Wetterstrand C, O'Connor JP, Hyre MJ, Loan JP, D'Andrea SE. Quantifying Bone and Skin Movement in the Residual Limb-Socket Interface of Individuals With Transtibial Limb Loss Using Dynamic Stereo X-Ray: Protocol for a Lower Limb Loss Cadaver and Clinical Study. JMIR Res Protoc 2024; 13:e57329. [PMID: 38669065 PMCID: PMC11087852 DOI: 10.2196/57329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 02/29/2024] [Accepted: 03/04/2024] [Indexed: 04/28/2024] Open
Abstract
BACKGROUND Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) DERR1-10.2196/57329.
Collapse
Affiliation(s)
- Jason T Maikos
- Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | - John M Chomack
- Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | - David V Herlihy
- Narrows Institute for Biomedical Research and Education, Inc., Brooklyn, NY, United States
| | - David N Paglia
- Department of Orthopaedics, Rutgers-New Jersey Medical School, Newark, NJ, United States
| | - Charlene Wetterstrand
- Department of Orthopaedics, Rutgers-New Jersey Medical School, Newark, NJ, United States
| | - J Patrick O'Connor
- Department of Orthopaedics, Rutgers-New Jersey Medical School, Newark, NJ, United States
| | - Michael J Hyre
- Narrows Institute for Biomedical Research and Education, Inc., Brooklyn, NY, United States
| | | | - Susan E D'Andrea
- Department of Kinesiology, College of Health Sciences, University of Rhode Island, Kingston, RI, United States
| |
Collapse
|
4
|
Abbott RE, Nishimwe A, Wiputra H, Breighner RE, Ellingson AM. OrthoFusion: A Super-Resolution Algorithm to Fuse Orthogonal CT Volumes. RESEARCH SQUARE 2024:rs.3.rs-4117386. [PMID: 38645068 PMCID: PMC11030529 DOI: 10.21203/rs.3.rs-4117386/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
OrthoFusion, an intuitive super-resolution algorithm, is presented in this study to enhance the spatial resolution of clinical CT volumes. The efficacy of OrthoFusion is evaluated, relative to high-resolution CT volumes (ground truth), by assessing image volume and derived bone morphological similarity, as well as its performance in specific applications in 2D-3D registration tasks. Results demonstrate that OrthoFusion significantly reduced segmentation time, while improving structural similarity of bone images and relative accuracy of derived bone model geometries. Moreover, it proved beneficial in the context of biplane videoradiography, enhancing the similarity of digitally reconstructed radiographs to radiographic images and improving the accuracy of relative bony kinematics. OrthoFusion's simplicity, ease of implementation, and generalizability make it a valuable tool for researchers and clinicians seeking high spatial resolution from existing clinical CT data. This study opens new avenues for retrospectively utilizing clinical images for research and advanced clinical purposes, while reducing the need for additional scans, mitigating associated costs and radiation exposure.
Collapse
|
5
|
Hebda PW, Majewski O. Minimally invasive fenestration for decompression of C2-C3 spinal stenosis. BMJ Case Rep 2023; 16:e254174. [PMID: 37963660 PMCID: PMC10649468 DOI: 10.1136/bcr-2022-254174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2023] Open
Abstract
Conventional techniques in neurosurgery such as laminectomy have been extensively displaced by minimally invasive types, owing to the character of complexity of cervical spinal region. Spinal canal stenosis at C2-C3 level is documented in the literature with the majority being caused by intervertebral disc herniations.This case reports a patient who presented with classical myelopathy symptoms and significant thickening of ligamentum flavum, while minimal spondylosis was detected at C2-C3 level. The decompression was performed from posterior approach and limited to the removal of ligamentum flavum with minimal resection of adjacent laminae, no fixation and no disc evacuation. After surgery, there was a significant improvement with preserved spinal stability.Although the anterior approach is more common for cervical spine, universal access site has not been defined in literature. We suggest that minimal decompression produces desirable effects with no need for fusion and preserving adequate stability of spinal complex.
Collapse
Affiliation(s)
- Patrycja Weronika Hebda
- Neurosurgery, Queen Elizabeth University Hospital, Glasgow, UK
- Neurosurgery, Szpital Specjalistyczny im Edmunda Biernackiego w Mielcu, Mielec, Poland
| | - Olaf Majewski
- Neurosurgery, Szpital Specjalistyczny im Edmunda Biernackiego w Mielcu, Mielec, Poland
| |
Collapse
|
6
|
Wade L, Needham L, Evans M, McGuigan P, Colyer S, Cosker D, Bilzon J. Examination of 2D frontal and sagittal markerless motion capture: Implications for markerless applications. PLoS One 2023; 18:e0293917. [PMID: 37943887 PMCID: PMC10635560 DOI: 10.1371/journal.pone.0293917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 10/21/2023] [Indexed: 11/12/2023] Open
Abstract
This study examined if occluded joint locations, obtained from 2D markerless motion capture (single camera view), produced 2D joint angles with reduced agreement compared to visible joints, and if 2D frontal plane joint angles were usable for practical applications. Fifteen healthy participants performed over-ground walking whilst recorded by fifteen marker-based cameras and two machine vision cameras (frontal and sagittal plane). Repeated measures Bland-Altman analysis illustrated that markerless standard deviation of bias and limits of agreement for the occluded-side hip and knee joint angles in the sagittal plane were double that of the camera-side (visible) hip and knee. Camera-side sagittal plane knee and hip angles were near or within marker-based error values previously observed. While frontal plane limits of agreement accounted for 35-46% of total range of motion at the hip and knee, Bland-Altman bias and limits of agreement (-4.6-1.6 ± 3.7-4.2˚) were actually similar to previously reported marker-based error values. This was not true for the ankle, where the limits of agreement (± 12˚) were still too high for practical applications. Our results add to previous literature, highlighting shortcomings of current pose estimation algorithms and labelled datasets. As such, this paper finishes by reviewing methods for creating anatomically accurate markerless training data using marker-based motion capture data.
Collapse
Affiliation(s)
- Logan Wade
- Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - Laurie Needham
- Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - Murray Evans
- Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - Polly McGuigan
- Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - Steffi Colyer
- Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - Darren Cosker
- Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - James Bilzon
- Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| |
Collapse
|
7
|
Menychtas D, Petrou N, Kansizoglou I, Giannakou E, Grekidis A, Gasteratos A, Gourgoulis V, Douda E, Smilios I, Michalopoulou M, Sirakoulis GC, Aggelousis N. Gait analysis comparison between manual marking, 2D pose estimation algorithms, and 3D marker-based system. FRONTIERS IN REHABILITATION SCIENCES 2023; 4:1238134. [PMID: 37744429 PMCID: PMC10511642 DOI: 10.3389/fresc.2023.1238134] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 08/25/2023] [Indexed: 09/26/2023]
Abstract
Introduction Recent advances in Artificial Intelligence (AI) and Computer Vision (CV) have led to automated pose estimation algorithms using simple 2D videos. This has created the potential to perform kinematic measurements without the need for specialized, and often expensive, equipment. Even though there's a growing body of literature on the development and validation of such algorithms for practical use, they haven't been adopted by health professionals. As a result, manual video annotation tools remain pretty common. Part of the reason is that the pose estimation modules can be erratic, producing errors that are difficult to rectify. Because of that, health professionals prefer the use of tried and true methods despite the time and cost savings pose estimation can offer. Methods In this work, the gait cycle of a sample of the elderly population on a split-belt treadmill is examined. The Openpose (OP) and Mediapipe (MP) AI pose estimation algorithms are compared to joint kinematics from a marker-based 3D motion capture system (Vicon), as well as from a video annotation tool designed for biomechanics (Kinovea). Bland-Altman (B-A) graphs and Statistical Parametric Mapping (SPM) are used to identify regions of statistically significant difference. Results Results showed that pose estimation can achieve motion tracking comparable to marker-based systems but struggle to identify joints that exhibit small, but crucial motion. Discussion Joints such as the ankle, can suffer from misidentification of their anatomical landmarks. Manual tools don't have that problem, but the user will introduce a static offset across the measurements. It is proposed that an AI-powered video annotation tool that allows the user to correct errors would bring the benefits of pose estimation to professionals at a low cost.
Collapse
Affiliation(s)
- Dimitrios Menychtas
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Nikolaos Petrou
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Ioannis Kansizoglou
- Laboratory of Robotics and Automation, Department of Production and Management Engineering, Democritus University of Thrace, Xanthi, Greece
| | - Erasmia Giannakou
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Athanasios Grekidis
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Antonios Gasteratos
- Laboratory of Robotics and Automation, Department of Production and Management Engineering, Democritus University of Thrace, Xanthi, Greece
| | - Vassilios Gourgoulis
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Eleni Douda
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Ilias Smilios
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Maria Michalopoulou
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| | - Georgios Ch. Sirakoulis
- Department of Electrical and Computer Engineering, Democritus University of Thrace, Xanthi, Greece
| | - Nikolaos Aggelousis
- Biomechanics Laboratory, Department of Physical Education and Sports Science, Democritus University of Thrace, Komotini, Greece
| |
Collapse
|
8
|
Willwacher S, Robbin J, Eßer T, Mai P. [Motion analysis systems in research and for practicing orthopedists]. ORTHOPADIE (HEIDELBERG, GERMANY) 2023:10.1007/s00132-023-04404-3. [PMID: 37391676 DOI: 10.1007/s00132-023-04404-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 06/12/2023] [Indexed: 07/02/2023]
Abstract
BACKGROUND Complex biomechanical motion analysis can provide relevant information for a variety of orthopedic problems. When purchasing motion analysis systems, in addition to the classical measurement quality criteria (validity, reliability, objectivity), spatial and temporal conditions, as well as the requirements for the qualification of the measuring personnel should be considered. APPLICATION In complex movement analysis, systems are used to determine kinematics, kinetics and muscle activity (electromyography). This article gives an overview of methods of complex biomechanical motion analysis for use in orthopaedic research or for individual patient care. In addition to the use for pure movement analysis, the use of movement analysis methods in the field of biofeedback training is discussed. ACQUISITION For the specific acquisition of motion analysis systems, it is recommended to contact professional societies (e.g., the German Society for Biomechanics),universities with existing motion analysis facilities or distributors in the field of biomechanics.
Collapse
Affiliation(s)
- Steffen Willwacher
- Institute for Advanced Biomechanics and Motion Studies, Hochschule Offenburg, Max-Planck-Str. 1, 77656, Offenburg, Deutschland.
| | - Johanna Robbin
- Institute for Advanced Biomechanics and Motion Studies, Hochschule Offenburg, Max-Planck-Str. 1, 77656, Offenburg, Deutschland
| | - Tanja Eßer
- Institut für Funktionelle Diagnostik, Köln, Deutschland, Im Mediapark 2, 50670
| | - Patrick Mai
- Institute for Advanced Biomechanics and Motion Studies, Hochschule Offenburg, Max-Planck-Str. 1, 77656, Offenburg, Deutschland
| |
Collapse
|
9
|
Welte L, Holowka NB, Kelly LA, Arndt A, Rainbow MJ. Mobility of the human foot's medial arch helps enable upright bipedal locomotion. Front Bioeng Biotechnol 2023; 11:1155439. [PMID: 37324435 PMCID: PMC10264861 DOI: 10.3389/fbioe.2023.1155439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 04/03/2023] [Indexed: 06/17/2023] Open
Abstract
Developing the ability to habitually walk and run upright on two feet is one of the most significant transformations to have occurred in human evolution. Many musculoskeletal adaptations enabled bipedal locomotion, including dramatic structural changes to the foot and, in particular, the evolution of an elevated medial arch. The foot's arched structure has previously been assumed to play a central role in directly propelling the center of mass forward and upward through leverage about the toes and a spring-like energy recoil. However, it is unclear whether or how the plantarflexion mobility and height of the medial arch support its propulsive lever function. We use high-speed biplanar x-ray measurements of foot bone motion on seven participants while walking and running and compare their motion to a subject-specific model without arch recoil. We show that regardless of intraspecific differences in medial arch height, arch recoil enables a longer contact time and favorable propulsive conditions at the ankle for walking upright on an extended leg. The generally overlooked navicular-medial cuneiform joint is primarily responsible for arch recoil in human arches. The mechanism through which arch recoil enables an upright ankle posture may have helped drive the evolution of the longitudinal arch after our last common ancestor with chimpanzees, who lack arch plantarflexion mobility during push-off. Future morphological investigations of the navicular-medial cuneiform joint will likely provide new interpretations of the fossil record. Our work further suggests that enabling medial arch recoil in footwear and surgical interventions may be critical for maintaining the ankle's natural propulsive ability.
Collapse
Affiliation(s)
- Lauren Welte
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada
| | - Nicholas B Holowka
- Department of Anthropology, University at Buffalo, Buffalo, NY, United States
| | - Luke A Kelly
- School of Human Movement and Nutrition Sciences, University of Queensland, Brisbane, QLD, Australia
| | - Anton Arndt
- The Swedish School of Sport and Health Sciences (GIH), Stockholm, Sweden
- Karolinska Institute, Stockholm, Sweden
| | - Michael J Rainbow
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada
| |
Collapse
|
10
|
Provini P, Camp AL, Crandell KE. Emerging biological insights enabled by high-resolution 3D motion data: promises, perspectives and pitfalls. J Exp Biol 2023; 226:286825. [PMID: 36752301 PMCID: PMC10038148 DOI: 10.1242/jeb.245138] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
Deconstructing motion to better understand it is a key prerequisite in the field of comparative biomechanics. Since Marey and Muybridge's work, technical constraints have been the largest limitation to motion capture and analysis, which, in turn, limited what kinds of questions biologists could ask or answer. Throughout the history of our field, conceptual leaps and significant technical advances have generally worked hand in hand. Recently, high-resolution, three-dimensional (3D) motion data have become easier to acquire, providing new opportunities for comparative biomechanics. We describe how adding a third dimension of information has fuelled major paradigm shifts, not only leading to a reinterpretation of long-standing scientific questions but also allowing new questions to be asked. In this paper, we highlight recent work published in Journal of Experimental Biology and influenced by these studies, demonstrating the biological breakthroughs made with 3D data. Although amazing opportunities emerge from these technical and conceptual advances, high-resolution data often come with a price. Here, we discuss challenges of 3D data, including low-throughput methodology, costly equipment, low sample sizes, and complex analyses and presentation. Therefore, we propose guidelines for how and when to pursue 3D high-resolution data. We also suggest research areas that are poised for major new biological advances through emerging 3D data collection.
Collapse
Affiliation(s)
- Pauline Provini
- Université Paris Cité, Inserm, System Engineering and Evolution Dynamics, F-75004 Paris, France
- Learning Planet Institute, F-75004 Paris, France
- Département Adaptations du Vivant, UMR 7179 CNRS/Muséum National d'Histoire Naturelle, F-75005 Paris, France
| | - Ariel L Camp
- Department of Musculoskeletal and Ageing Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool L78TX, UK
| | | |
Collapse
|
11
|
Ramsdell JC, Scott ME, Beynnon BD, Fiorentino NM. Does interpolation and intra-user variability affect the accuracy of arthrokinematic measurements in the knee? A dual fluoroscopic imaging and model-based tracking study. Med Eng Phys 2023; 114:103968. [PMID: 37030894 PMCID: PMC10115154 DOI: 10.1016/j.medengphy.2023.103968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 02/07/2023] [Accepted: 03/10/2023] [Indexed: 03/15/2023]
Abstract
Model-based tracking (MBT) is a time-consuming and semiautomatic approach, and thus subject to errors during the tracking process. The present study aimed primarily to quantify the effects that interpolation and intra-user variability associated with MBT have on the kinematic and arthrokinematic measurements in comparison to a gold standard radiostereometric analysis (RSA). Cadaveric knee specimens were imaged at 125 Hz while simulating standing, walking, jogging, and lunging motions. (Arthro)kinematic metrics were calculated via MBT without interpolation, MBT with two interpolation techniques when every fifth or tenth frame was analyzed, and RSA. Tracking the same activity multiple times affected (p-value, largest mean difference) the flexion-extension (FE) joint angle during walking (0.03, 0.6°), and the internal-external joint angle during jogging (0.048, -0.9°). Only during jogging for the FE joint angle was there an effect of interpolation (0.046, 0.3°). Neither tracking multiple times nor interpolation affected arthrokinematic metrics (contact path locations and excursions). The present study is the first to quantify the effects that intra-user variability and interpolation have on the (arthro)kinematic measurement accuracy using MBT. Results suggest interpolation may be used without sacrificing (arthro)kinematic outcome measurement accuracy and the errors associated with intra-user variability, while small, were larger than errors due to interpolation.
Collapse
Affiliation(s)
- John C Ramsdell
- Department of Electrical and Biomedical Engineering, University of Vermont, USA
| | - Marit E Scott
- Department of Electrical and Biomedical Engineering, University of Vermont, USA
| | - Bruce D Beynnon
- Department of Electrical and Biomedical Engineering, University of Vermont, USA; Department of Orthopaedics and Rehabilitation, University of Vermont
| | - Niccolo M Fiorentino
- Department of Electrical and Biomedical Engineering, University of Vermont, USA; Department of Orthopaedics and Rehabilitation, University of Vermont; Department of Mechanical Engineering, University of Vermont.
| |
Collapse
|
12
|
Petersen ET, Vind TD, Jürgens-Lahnstein JH, Christensen R, de Raedt S, Brüel A, Rytter S, Andersen MS, Stilling M. Evaluation of automated radiostereometric image registration in total knee arthroplasty utilizing a synthetic-based and a CT-based volumetric model. J Orthop Res 2023; 41:436-446. [PMID: 35532010 PMCID: PMC10084430 DOI: 10.1002/jor.25359] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 03/28/2022] [Accepted: 05/05/2022] [Indexed: 02/04/2023]
Abstract
Radiostereometic analysis (RSA) is an accurate method for rigid body pose (position and orientation) in three-dimensional space. Traditionally, RSA is based on insertion of periprosthetic tantalum markers and manual implant contour selection which limit clinically application. We propose an automated image registration technique utilizing digitally reconstructed radiographs (DRR) of computed tomography (CT) volumetric bone models (autorsa-bone) as a substitute for tantalum markers. Furthermore, an automated synthetic volumetric representation of total knee arthroplasty implant models (autorsa-volume) to improve previous silhouette-projection methods (autorsa-surface). As reference, we investigated the accuracy of implanted tantalum markers (marker) or a conventional manually contour-based method (mbrsa) for the femur and tibia. The data are presented as mean (standard deviation). The autorsa-bone method displayed similar accuracy of -0.013 (0.075) mm compared to the gold standard method (marker) of -0.013 (0.085). The autorsa-volume with 0.034 (0.106) mm did not markedly improve the autorsa-surface with 0.002 (0.129) mm, and none of these reached the mbrsa method of -0.009 (0.094) mm. In conclusion, marker-free RSA is feasible with similar accuracy as gold standard utilizing DRR and CT obtained volumetric bone models. Furthermore, utilizing synthetic generated volumetric implant models could not improve the silhouette-based method. However, with a slight loss of accuracy the autorsa methods provide a feasible automated alternative to the semi-automated method.
Collapse
Affiliation(s)
- Emil Toft Petersen
- University Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Tobias Dahl Vind
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Jonathan Hugo Jürgens-Lahnstein
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Rasmus Christensen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Sepp de Raedt
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Annemarie Brüel
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
| | - Søren Rytter
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | | | - Maiken Stilling
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
13
|
Wan Q, Zhang A, Bai H, Liu Y, Chen H, Zhao X, Wang X, Han Q, Wang J. Cause analysis of the liner dissociation of a customized reverse shoulder prosthesis based on finite element analysis. Front Bioeng Biotechnol 2022; 10:1038116. [DOI: 10.3389/fbioe.2022.1038116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022] Open
Abstract
Background: Dissociation of the polyethylene liner after reverse shoulder arthroplasty could cause shoulder dislocation that could not achieve closed reduction. The cause of liner dissociation is currently unclear.Method: Non-homogeneous model of the bone was constructed and dynamic finite element analysis was utilized to simulate the impingement of the polyethylene liner and scapula during humeral adduction. The stress distribution of the fixation claws, their degree of deformation (DOD), and the stress of the impingement sites in three initial humeral postures (neutral, 30° flexion, and 30° extension) were measured and analyzed. The influence of the liner material stiffness was also investigated.Result: The impingement stress on the liner and scapula was 100–200 MPa, and different humeral postures caused different locations of impingement points. The fixation claws’ maximum principal stress (MPS) results were below 5 MPa. In the connection area between some fixation claws and the liner, compressive stresses on the inside and tensile stresses on the outside were observed, which showed that the fixation claws were prone to deform toward the center direction. The maximum DOD results of three initial humeral postures (neutral, 30° flexion, and 30° extension) were 3.6%, 2.8%, and 3.5%, respectively. The maximum DOD results of neutral initial humeral posture were 0.51% and 11.4% when the elastic modulus of the liner was increased and decreased by a factor of 10, respectively.Conclusion: The humeral adduction impingement could lead to the deformation of the claw-shaped liner fixation structure, which might be one of the reasons for the liner dissociation. The increased stiffness of the liner material helped to reduce the deformation of the fixation structure.
Collapse
|
14
|
Sun X, Su W, Zhang F, Ye D, Wang S, Zhang S, Fu W. Changes of the in vivo kinematics of the human medial longitudinal foot arch, first metatarsophalangeal joint, and the length of plantar fascia in different running patterns. Front Bioeng Biotechnol 2022; 10:959807. [PMID: 36524051 PMCID: PMC9745187 DOI: 10.3389/fbioe.2022.959807] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 11/07/2022] [Indexed: 09/26/2023] Open
Abstract
Accurately obtaining the in vivo motion of the medial longitudinal arch (MLA), first metatarsophalangeal joint (MTPJ), and plantar fascia (PF) is essential for analyzing the biomechanics of these structures in different running strike patterns. Most previous studies on the biomechanics of the MLA, first MTPJ, and PF have been based on traditional skin-marker-based motion capture, which cannot acquire the natural foot motion. Therefore, this study aimed to 1) describe the movement of the MLA, first MTPJ, and PF during running by using the high-speed dual fluoroscopic imaging system (DFIS) and 2) explore changes of the in vivo kinematics of the MLA and first MTPJ, and the length of the PF during the stance phase of running with different foot strike patterns. Fifteen healthy male runners all of whom ran with a regular rearfoot strike (RFS) pattern were required to run with forefoot strike (FFS) and RFS patterns. Computed tomography scans were taken from each participant's right foot for the construction of 3D models (the calcaneus, first metatarsal, and first proximal phalanges) and local coordinate systems. A high-speed DFIS (100 Hz) and 3D force platform (2,000 Hz) were used to acquire X-ray images of the foot bones and ground reaction force data during the stance phase of running (3 m/s ± 5%) simultaneously. Then, 3D-2D registration was used to obtain the in vivo kinematic data of the MLA and first MTPJ and the length of the PF. When compared with RFS, in FFS, 1) the range of motion (ROM) of the medial/lateral (5.84 ± 5.61 mm vs. 0.75 ± 3.38 mm, p = 0.002), anterior/posterior (14.64 ± 4.33 mm vs. 11.18 ± 3.56 mm, p = 0.010), plantarflexion/dorsiflexion (7.13 ± 3.22° vs. 1.63 ± 3.29°, p < 0.001), and adduction/abduction (-3.89 ± 3.85° vs. -0.64 ± 4.39°, p = 0.034) motions of the MLA were increased significantly; 2) the ROM of the anterior/posterior (7.81 ± 2.84 mm vs. 6.24 ± 3.43 mm, p = 0.003), superior/inferior (2.11 ± 2.06 mm vs. -0.57 ± 1.65 mm, p = 0.001), and extension/flexion (-9.68 ± 9.16° vs. -5.72 ± 7.33°, p = 0.018) motions of the first MTPJ were increased significantly; 3) the maximum strain (0.093 ± 0.023 vs. 0.075 ± 0.020, p < 0.001) and the maximum power (4.36 ± 1.51 W/kg vs. 3.06 ± 1.39 W/kg, p < 0.001) of the PF were increased significantly. Running with FFS may increase deformation, energy storage, and release of the MLA and PF, as well as the push-off effect of the MTPJ. Meanwhile, the maximum extension angle of the first MTPJ and MLA deformation increased in FFS, which showed that the PF experienced more stretch and potentially indicated that FFS enhanced the PF mechanical responses.
Collapse
Affiliation(s)
- Xiaole Sun
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
- School of Exercise and Health, Nanjing Sport Institute, Nanjing, China
| | - Wanyan Su
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
| | - Faning Zhang
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
| | - Dongqiang Ye
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
| | - Shaobai Wang
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, Shanghai University of Sport, Shanghai, China
| | - Shen Zhang
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
- School of Athletic Performance, Shanghai University of Sport, Shanghai, China
| | - Weijie Fu
- School of Exercise and Health, Shanghai University of Sport, Shanghai, China
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, Shanghai University of Sport, Shanghai, China
| |
Collapse
|
15
|
Kerkhof F, Kenney D, Ogle M, Shelby T, Ladd A. The biomechanics of osteoarthritis in the hand: Implications and prospects for hand therapy. J Hand Ther 2022; 35:367-376. [PMID: 36509610 DOI: 10.1016/j.jht.2022.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND The unique anatomy of the human hand makes it possible to carefully manipulate tools, powerfully grasp objects, and even throw items with precision. These apparent contradictory functions of the hand, high mobility for manual dexterity vs high stability during forceful grasping, imply that daily activities impose a high strain on a relatively instable joint. This makes the hand susceptible to joint disorders such as osteoarthritis. Both systemic (eg, genetics, hormones) and mechanical factors (eg, joint loading) are important in the development of osteoarthritis, but the precise pathomechanism remains largely unknown. This paper focuses on the biomechanical factors in the disease process and how hand therapists can use this knowledge to improve treatment and research. CONCLUSION Multiple factors are involved in the onset and development of osteoarthritis in the hand. Comprehension of the biomechanics helps clinicians establish best practices for orthotics intervention, exercise, and joint protection programs even in de absence of clear evidence-based guidelines. The effect and reach of hand therapy for OA patients can be expanded substantially when intervention parameters are optimized and barriers to early referrals, access reimbursement, and adherence are addressed. Close and early collaboration between hand therapists and primary care, women's health, rheumatology, and hand surgery providers upon diagnosis, and with hand surgeons pre and postoperatively, combined with advances in the supporting science and strategies to enhance adherence, appear to be a promising way forward.
Collapse
Affiliation(s)
- Faes Kerkhof
- Chase Hand and Upper Limb Center, Stanford University, Palo Alto, CA, USA.
| | - Deborah Kenney
- Chase Hand and Upper Limb Center, Stanford University, Palo Alto, CA, USA
| | - Miranda Ogle
- Chase Hand and Upper Limb Center, Stanford University, Palo Alto, CA, USA
| | - Tara Shelby
- Chase Hand and Upper Limb Center, Stanford University, Palo Alto, CA, USA
| | - Amy Ladd
- Chase Hand and Upper Limb Center, Stanford University, Palo Alto, CA, USA
| |
Collapse
|
16
|
Wade L, Needham L, McGuigan P, Bilzon J. Applications and limitations of current markerless motion capture methods for clinical gait biomechanics. PeerJ 2022; 10:e12995. [PMID: 35237469 PMCID: PMC8884063 DOI: 10.7717/peerj.12995] [Citation(s) in RCA: 42] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 02/02/2022] [Indexed: 01/11/2023] Open
Abstract
BACKGROUND Markerless motion capture has the potential to perform movement analysis with reduced data collection and processing time compared to marker-based methods. This technology is now starting to be applied for clinical and rehabilitation applications and therefore it is crucial that users of these systems understand both their potential and limitations. This literature review aims to provide a comprehensive overview of the current state of markerless motion capture for both single camera and multi-camera systems. Additionally, this review explores how practical applications of markerless technology are being used in clinical and rehabilitation settings, and examines the future challenges and directions markerless research must explore to facilitate full integration of this technology within clinical biomechanics. METHODOLOGY A scoping review is needed to examine this emerging broad body of literature and determine where gaps in knowledge exist, this is key to developing motion capture methods that are cost effective and practically relevant to clinicians, coaches and researchers around the world. Literature searches were performed to examine studies that report accuracy of markerless motion capture methods, explore current practical applications of markerless motion capture methods in clinical biomechanics and identify gaps in our knowledge that are relevant to future developments in this area. RESULTS Markerless methods increase motion capture data versatility, enabling datasets to be re-analyzed using updated pose estimation algorithms and may even provide clinicians with the capability to collect data while patients are wearing normal clothing. While markerless temporospatial measures generally appear to be equivalent to marker-based motion capture, joint center locations and joint angles are not yet sufficiently accurate for clinical applications. Pose estimation algorithms are approaching similar error rates of marker-based motion capture, however, without comparison to a gold standard, such as bi-planar videoradiography, the true accuracy of markerless systems remains unknown. CONCLUSIONS Current open-source pose estimation algorithms were never designed for biomechanical applications, therefore, datasets on which they have been trained are inconsistently and inaccurately labelled. Improvements to labelling of open-source training data, as well as assessment of markerless accuracy against gold standard methods will be vital next steps in the development of this technology.
Collapse
Affiliation(s)
- Logan Wade
- Department for Health, University of Bath, Bath, United Kingdom,Centre for Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - Laurie Needham
- Department for Health, University of Bath, Bath, United Kingdom,Centre for Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - Polly McGuigan
- Department for Health, University of Bath, Bath, United Kingdom,Centre for Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom
| | - James Bilzon
- Department for Health, University of Bath, Bath, United Kingdom,Centre for Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, United Kingdom,Centre for Sport Exercise and Osteoarthritis Research Versus Arthritis, University of Bath, Bath, United Kingdom
| |
Collapse
|
17
|
Mozingo JD, Akbari-Shandiz M, Van Straaten MG, Murthy NS, Schueler BA, Holmes DR, McCollough CH, Zhao KD. Comparison of glenohumeral joint kinematics between manual wheelchair tasks and implications on the subacromial space: A biplane fluoroscopy study. J Electromyogr Kinesiol 2022; 62:102350. [PMID: 31481296 PMCID: PMC7036020 DOI: 10.1016/j.jelekin.2019.08.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 07/12/2019] [Accepted: 08/19/2019] [Indexed: 02/03/2023] Open
Abstract
Scapula and humerus motion associated with common manual wheelchair tasks is hypothesized to reduce the subacromial space. However, previous work relied on either marker-based motion capture for kinematic measures, which is prone to skin-motion artifact; or ultrasound imaging for arthrokinematic measures, which are 2D and acquired in statically-held positions. The aim of this study was to use a fluoroscopy-based approach to accurately quantify glenohumeral kinematics during manual wheelchair use, and compare tasks for a subset of parameters theorized to be associated with mechanical impingement. Biplane images of the dominant shoulder were acquired during scapular plane elevation, propulsion, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury. A computed tomography scan of the shoulder was obtained, and model-based tracking was used to quantify six-degree-of-freedom glenohumeral kinematics. Axial rotation and superior/inferior and anterior/posterior humeral head positions were characterized for full activity cycles and compared between tasks. The change in the subacromial space was also determined for the period of each task defined by maximal change in the aforementioned parameters. Propulsion, sideways lean, and weight-relief raise, but not scapular plane elevation, were marked by mean internal rotation (8.1°, 10.8°, 14.7°, -49.2° respectively). On average, the humeral head was most superiorly positioned during the weight-relief raise (1.6 ± 0.9 mm), but not significantly different from the sideways lean (0.8 ± 1.1 mm) (p = 0.191), and much of the task was characterized by inferior translation. Scaption was the only task without a defined period of superior translation on average. Pairwise comparisons revealed no significant differences between tasks for anterior/posterior position (task means range: 0.1-1.7 mm), but each task exhibited defined periods of anterior translation. There was not a consistent trend across tasks between internal rotation, superior translation, and anterior translation with reductions in the subacromial space. Further research is warranted to determine the likelihood of mechanical impingement during these tasks based on the measured task kinematics and reductions in the subacromial space.
Collapse
Affiliation(s)
- Joseph D. Mozingo
- Biomedical Engineering and Physiology Graduate Program,
Mayo Clinic Graduate School of Biomedical Sciences, Mayo Clinic, Rochester, MN,
USA,Department of Physical Medicine and Rehabilitation, Mayo
Clinic, Rochester, MN, USA
| | | | | | | | | | - David R. Holmes
- Department of Physiology and Biomedical Engineering, Mayo
Clinic, Rochester, MN, USA
| | | | - Kristin D. Zhao
- Department of Physical Medicine and Rehabilitation, Mayo
Clinic, Rochester, MN, USA
| |
Collapse
|
18
|
Wiseman ALA, Demuth OE, Hutchinson JR. A Guide to Inverse Kinematic Marker-Guided Rotoscoping using IK Solvers. Integr Org Biol 2022; 4:obac002. [PMID: 35261964 PMCID: PMC8896983 DOI: 10.1093/iob/obac002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
X-ray Reconstruction of Moving Morphology (XROMM) permits researchers to see beneath the skin, usually to see musculoskeletal movements. These movements can be tracked and later used to provide information regarding the mechanics of movement. Here, we discuss “IK marker-guided rotoscoping”—a method that combines inverse kinematic solvers with that of traditional scientific rotoscoping methods to quickly and efficiently overlay 3D bone geometries with the X-ray shadows from XROMM data. We use a case study of three Nile crocodiles’ (Crocodylus niloticus) forelimbs and hindlimbs to evaluate this method. Within these limbs, different marker configurations were used: some configurations had six markers, others had five markers, and all forelimb data only had three markers. To evaluate IK marker-guided rotoscoping, we systematically remove markers in the six-marker configuration and then test the magnitudes of deviation in translations and rotations of the rigged setup with fewer markers versus those of the six-marker configuration. We establish that IK marker-guided rotoscoping is a suitable method for “salvaging” data that may have too few markers.
Collapse
Affiliation(s)
- Ashleigh L A Wiseman
- Structure and Motion Laboratory, Comparative Biomedical Sciences, Royal Veterinary College, Hatfield, UK
- McDonald Institute for Archaeological Research, University of Cambridge, Cambridge, UK
| | - Oliver E Demuth
- Structure and Motion Laboratory, Comparative Biomedical Sciences, Royal Veterinary College, Hatfield, UK
- Department of Earth Sciences, University of Cambridge, Cambridge, UK
| | - John R Hutchinson
- Structure and Motion Laboratory, Comparative Biomedical Sciences, Royal Veterinary College, Hatfield, UK
| |
Collapse
|
19
|
Perevoshchikova N, Moerman KM, Akhbari B, Bindra R, Maharaj JN, Lloyd DG, Gomez Cerezo M, Carr A, Vaquette C, Saxby DJ. Finite element analysis of the performance of additively manufactured scaffolds for scapholunate ligament reconstruction. PLoS One 2021; 16:e0256528. [PMID: 34797871 PMCID: PMC8604338 DOI: 10.1371/journal.pone.0256528] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Accepted: 08/07/2021] [Indexed: 12/11/2022] Open
Abstract
Rupture of the scapholunate interosseous ligament can cause the dissociation of scaphoid and lunate bones, resulting in impaired wrist function. Current treatments (e.g., tendon-based surgical reconstruction, screw-based fixation, fusion, or carpectomy) may restore wrist stability, but do not address regeneration of the ruptured ligament, and may result in wrist functional limitations and osteoarthritis. Recently a novel multiphasic bone-ligament-bone scaffold was proposed, which aims to reconstruct the ruptured ligament, and which can be 3D-printed using medical-grade polycaprolactone. This scaffold is composed of a central ligament-scaffold section and features a bone attachment terminal at either end. Since the ligament-scaffold is the primary load bearing structure during physiological wrist motion, its geometry, mechanical properties, and the surgical placement of the scaffold are critical for performance optimisation. This study presents a patient-specific computational biomechanical evaluation of the effect of scaffold length, and positioning of the bone attachment sites. Through segmentation and image processing of medical image data for natural wrist motion, detailed 3D geometries as well as patient-specific physiological wrist motion could be derived. This data formed the input for detailed finite element analysis, enabling computational of scaffold stress and strain distributions, which are key predictors of scaffold structural integrity. The computational analysis demonstrated that longer scaffolds present reduced peak scaffold stresses and a more homogeneous stress state compared to shorter scaffolds. Furthermore, it was found that scaffolds attached at proximal sites experience lower stresses than those attached at distal sites. However, scaffold length, rather than bone terminal location, most strongly influences peak stress. For each scaffold terminal placement configuration, a basic metric was computed indicative of bone fracture risk. This metric was the minimum distance from the bone surface to the internal scaffold bone terminal. Analysis of this minimum bone thickness data confirmed further optimisation of terminal locations is warranted.
Collapse
Affiliation(s)
- Nataliya Perevoshchikova
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| | - Kevin M. Moerman
- Biomechanics Research Centre, National University of Ireland Galway, Galway, Ireland
- Center for Extreme Bionics at the Media Lab, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Bardiya Akhbari
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, Rhode Island, United States of America
| | - Randy Bindra
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
- School of Medicine, Griffith University, Gold Coast, QLD, Australia
| | - Jayishni N. Maharaj
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| | - David G. Lloyd
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| | | | - Amelia Carr
- School of Dentistry, University of Queensland, Herston, QLD, Australia
| | - Cedryck Vaquette
- School of Dentistry, University of Queensland, Herston, QLD, Australia
| | - David J. Saxby
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| |
Collapse
|
20
|
Rohwedder T. Biomechanics of the Canine Elbow Joint. Vet Med Sci 2021. [DOI: 10.5772/intechopen.99569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
The canine elbow joint is a complex joint, whose musculoskeletal anatomy is well investigated. During the last 30 years kinematic analysis has gained importance in veterinary research and kinematics of the healthy and medial coronoid disease affected canine elbow joint are progressively investigated. Video-kinematographic analysis represents the most commonly used technique and multiple studies have investigated the range of motion, angular velocity, duration of swing and stance phase, stride length and other kinematic parameters, mostly in the sagittal plane only. However, this technique is more error-prone and data gained by video-kinematography represent the kinematics of the whole limb including the soft tissue envelope. A more precise evaluation of the in vivo bone and joint movement can only been achieved using fluoroscopic kinematography. Based on recent studies significant differences in the motion pattern between healthy joints and elbows with medial coronoid disease could be detected. Thereby not only adaptive changes, caused by pain and lameness, could be described, but primary changes in the micromotion of the joint forming bones could be found, which potentially represent new factors in the pathogenesis of medial coronoid disease. This chapter gives a review of current literature on elbow joint kinematics, with particular focus onto pathologic biomechanics in dysplastic canine elbows.
Collapse
|
21
|
Maikos JT, Chomack JM, Loan JP, Bradley KM, D'Andrea SE. Effects of Prosthetic Socket Design on Residual Femur Motion Using Dynamic Stereo X-Ray - A Preliminary Analysis. Front Bioeng Biotechnol 2021; 9:697651. [PMID: 34447740 PMCID: PMC8383143 DOI: 10.3389/fbioe.2021.697651] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 07/21/2021] [Indexed: 11/13/2022] Open
Abstract
Individuals with transfemoral amputation experience relative motion between their residual limb and prosthetic socket, which can cause inefficient dynamic load transmission and secondary comorbidities that limit mobility. Accurately measuring the relative position and orientation of the residual limb relative to the prosthetic socket during dynamic activities can provide great insight into the complex mechanics of the socket/limb interface. Five participants with transfemoral amputation were recruited for this study. All participants had a well-fitting, ischial containment socket and were also fit with a compression/release stabilization socket. Participants underwent an 8-wk, randomized crossover trial to compare differences between socket types. Dynamic stereo x-ray was used to quantify three-dimensional residual bone kinematics relative to the prosthetic socket during treadmill walking at self-selected speed. Comfort, satisfaction, and utility were also assessed. There were no significant differences in relative femur kinematics between socket types in the three rotational degrees of freedom, as well as anterior-posterior and medial-lateral translation (p > 0.05). The ischial containment socket demonstrated significantly less proximal-distal translation (pistoning) of the femur compared to the compression/release stabilization socket during the gait cycle (p < 0.05), suggesting that the compression/release stabilization socket provided less control of the residual femur during distal translation. No significant differences in comfort and utility were found between socket types (p > 0.05). The quantitative, dynamic analytical tools used in the study were sensitive to distinguish differences in three-dimensional residual femur motion between two socket types, which can serve as a platform for future comparative effectiveness studies of socket technology.
Collapse
Affiliation(s)
- Jason T Maikos
- VISN 2 Biomechanics Research for the Advancement of Veteran Outcomes Laboratory, Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | - John M Chomack
- VISN 2 Biomechanics Research for the Advancement of Veteran Outcomes Laboratory, Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | | | | | - Susan E D'Andrea
- Virtual Reality and Motion Analysis Rehabilitation Laboratory, Providence VA Medical Center, Providence, RI, United States
| |
Collapse
|
22
|
Wagner FC, Reese S, Gerlach K, Böttcher P, Mülling CKW. Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy. BMC Vet Res 2021; 17:223. [PMID: 34172051 PMCID: PMC8229380 DOI: 10.1186/s12917-021-02914-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 05/24/2021] [Indexed: 01/20/2023] Open
Abstract
Background Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. Results A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. Conclusion In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs. Supplementary Information The online version contains supplementary material available at 10.1186/s12917-021-02914-w.
Collapse
Affiliation(s)
- Franziska C Wagner
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany.
| | - Sven Reese
- Chair of Anatomy, Histology and Embryology, Department of Veterinary Sciences, LMU Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - Kerstin Gerlach
- Department for Horses, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 21, 04103, Leipzig, Germany
| | - Peter Böttcher
- Small Animal Clinic, Department of Veterinary Medicine, Freie Universität Berlin, Oertzenweg 19 b, 14163, Berlin, Germany
| | - Christoph K W Mülling
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany
| |
Collapse
|
23
|
Akhbari B, Shah KN, Morton AM, Moore DC, Weiss APC, Wolfe SW, Crisco JJ. Biomechanics of the Distal Radioulnar Joint During In Vivo Forearm Pronosupination. J Wrist Surg 2021; 10:208-215. [PMID: 34109063 PMCID: PMC8169167 DOI: 10.1055/s-0040-1722334] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 11/12/2020] [Indexed: 10/22/2022]
Abstract
Background Ulnar variance (UV) and center of rotation (COR) location at the level of the distal radioulnar joint (DRUJ) change with forearm rotation. Nevertheless, these parameters have not been assessed dynamically during active in vivo pronosupination. This assessment could help us to improve our diagnosis and treatment strategies. Questions/purposes We sought to (1) mathematically model the UV change, and (2) determine the dynamic COR's location during active pronosupination. Methods We used biplanar videoradiography to study DRUJ during in vivo pronation and supination in nine healthy subjects. UV was defined as the proximal-distal distance of ulnar fovea with respect to the radial sigmoid notch, and COR was calculated using helical axis of motion parameters. The continuous change of UV was evaluated using a generalized linear regression model. Results A second-degree polynomial with R 2 of 0.85 was able to model the UV changes. Maximum negative UV occurred at 38.0 degrees supination and maximum positive UV occurred at maximum pronation. At maximum pronation, the COR was located 0.5 ± 1.8 mm ulnarly and 0.6 ± 0.8 mm volarly from the center of the ulnar fovea, while at maximum supination, the COR was located 0.2 ± 0.6 mm radially and 2.0 ± 0.5 mm volarly. Conclusion Changes in UV and volar translation of the COR are nonlinear at the DRUJ during pronosupination. Clinical Relevance Understanding the dynamic nature of UV as a function of pronosupination can help guide accurate evaluation and treatment of wrist pathology where the UV is an important consideration. The dynamic behavior of COR might be useful in designing DRUJ replacement implants to match the anatomical motion.
Collapse
Affiliation(s)
- Bardiya Akhbari
- Center for Biomedical Engineering, Brown University, Providence, Rhode Island
| | - Kalpit N. Shah
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Amy M. Morton
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Douglas C. Moore
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Arnold-Peter C. Weiss
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
- Division of Hand, Upper Extremity & Microvascular Surgery, Department of Orthopaedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Scott W. Wolfe
- Hand and Upper Extremity Center, Hospital for Special Surgery, New York, New York
- Department of Orthopaedic Surgery, Weill Medical College of Cornell University, New York, New York
| | - Joseph J. Crisco
- Center for Biomedical Engineering, Brown University, Providence, Rhode Island
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| |
Collapse
|
24
|
McHugh B, Akhbari B, Morton AM, Moore DC, Crisco JJ. Optical motion capture accuracy is task-dependent in assessing wrist motion. J Biomech 2021; 120:110362. [PMID: 33752132 DOI: 10.1016/j.jbiomech.2021.110362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Revised: 01/24/2021] [Accepted: 02/22/2021] [Indexed: 11/18/2022]
Abstract
Optical motion capture (OMC) systems are commonly used to capture in-vivo three-dimensional joint kinematics. However, the skin-based markers may not reflect the underlying bone movement, a source of error known as soft tissue artifact (STA). This study examined STA during wrist motion by evaluating the agreement between OMC and biplanar videoradiography (BVR). Nine subjects completed 7 different wrist motion tasks: doorknob rotation to capture supination and pronation, radial-ulnar deviation, flexion-extension, circumduction, hammering, and pitcher pouring. BVR and OMC captured the motion simultaneously. Wrist kinematics were quantified using helical motion parameters of rotation and translation, and Bland-Altman analysis quantified the mean difference (bias) and 95% limit of agreement (LOA). The rotational bias of doorknob pronation, a median bias of -4.9°, was significantly larger than the flexion-extension (0.7°, p < 0.05) and radial-ulnar deviation (1.8°, p < 0.01) tasks. The rotational LOA range was significantly smaller in the flexion-extension task (5.9°) compared to pitcher (11.6°, p < 0.05) and doorknob pronation (17.9°, p < 0.05) tasks. The translation bias did not differ between tasks. The translation LOA range was significantly larger in circumduction (9.8°) compared to the radial-ulnar deviation (6.3°, p < 0.05) and pitcher (3.4°, p < 0.05) tasks. While OMC technology has a wide-range of successful applications, we demonstrated it has relatively poor agreement with BVR in tracking wrist motion, and that the agreement depends on the nature and direction of wrist motion.
Collapse
Affiliation(s)
- Brian McHugh
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI 02912, United States.
| | - Bardiya Akhbari
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI 02912, United States.
| | - Amy M Morton
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903, United States.
| | - Douglas C Moore
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903, United States.
| | - Joseph J Crisco
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI 02912, United States; Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903, United States.
| |
Collapse
|
25
|
Akhbari B, Morton AM, Moore DC, Crisco JJ. Biplanar Videoradiography to Study the Wrist and Distal Radioulnar Joints. J Vis Exp 2021:10.3791/62102. [PMID: 33616093 PMCID: PMC8182367 DOI: 10.3791/62102] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
Accurate measurement of skeletal kinematics in vivo is essential for understanding normal joint function, the influence of pathology, disease progression, and the effects of treatments. Measurement systems that use skin surface markers to infer skeletal motion have provided important insight into normal and pathological kinematics, however, accurate arthrokinematics cannot be attained using these systems, especially during dynamic activities. In the past two decades, biplanar videoradiography (BVR) systems have enabled many researchers to directly study the skeletal kinematics of the joints during activities of daily living. To implement BVR systems for the distal upper extremity, videoradiographs of the distal radius and the hand are acquired from two calibrated X-ray sources while a subject performs a designated task. Three-dimensional (3D) rigid-body positions are computed from the videoradiographs via a best-fit registrations of 3D model projections onto to each BVR view. The 3D models are density-based image volumes of the specific bone derived from independently acquired computed-tomography data. Utilizing graphics processor units and high-performance computing systems, this model-based tracking approach is shown to be fast and accurate in evaluating the wrist and distal radioulnar joint biomechanics. In this study, we first summarized the previous studies that have established the submillimeter and subdegree agreement of BVR with an in vitro optical motion capture system in evaluating the wrist and distal radioulnar joint kinematics. Furthermore, we used BVR to compute the center of rotation behavior of the wrist joint, to evaluate the articulation pattern of the components of the implant upon one another, and to assess the dynamic change of ulnar variance during pronosupination of the forearm. In the future, carpal bones may be captured in greater detail with the addition of flat panel X-ray detectors, more X-ray sources (i.e., multiplanar videoradiography), or advanced computer vision algorithms.
Collapse
Affiliation(s)
| | - Amy M Morton
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital
| | - Douglas C Moore
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital
| | - Joseph J Crisco
- Center for Biomedical Engineering, Brown University; Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital
| |
Collapse
|
26
|
Welte L, Kelly LA, Kessler SE, Lieberman DE, D'Andrea SE, Lichtwark GA, Rainbow MJ. The extensibility of the plantar fascia influences the windlass mechanism during human running. Proc Biol Sci 2021; 288:20202095. [PMID: 33468002 DOI: 10.1098/rspb.2020.2095] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The arch of the human foot is unique among hominins as it is compliant at ground contact but sufficiently stiff to enable push-off. These behaviours are partly facilitated by the ligamentous plantar fascia whose role is central to two mechanisms. The ideal windlass mechanism assumes that the plantar fascia has a nearly constant length to directly couple toe dorsiflexion with a change in arch shape. However, the plantar fascia also stretches and then shortens throughout gait as the arch-spring stores and releases elastic energy. We aimed to understand how the extensible plantar fascia could behave as an ideal windlass when it has been shown to strain throughout gait, potentially compromising the one-to-one coupling between toe arc length and arch length. We measured foot bone motion and plantar fascia elongation using high-speed X-ray during running. We discovered that toe plantarflexion delays plantar fascia stretching at foot strike, which probably modifies the distribution of the load through other arch tissues. Through a pure windlass effect in propulsion, a quasi-isometric plantar fascia's shortening is delayed to later in stance. The plantar fascia then shortens concurrently to the windlass mechanism, likely enhancing arch recoil at push-off.
Collapse
Affiliation(s)
- Lauren Welte
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, Ontario, Canada
| | - Luke A Kelly
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Queensland, Australia
| | - Sarah E Kessler
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Queensland, Australia.,Department of Human Evolutionary Biology, Harvard University, Cambridge, MA, USA
| | - Daniel E Lieberman
- Department of Human Evolutionary Biology, Harvard University, Cambridge, MA, USA
| | - Susan E D'Andrea
- Department of Kinesiology, University of Rhode Island, Kingston, RI, USA
| | - Glen A Lichtwark
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Queensland, Australia
| | - Michael J Rainbow
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, Ontario, Canada
| |
Collapse
|
27
|
Abstract
X-Ray Reconstruction of Moving Morphology (XROMM), though traditionally used for studies of in vivo skeletal kinematics, can also be used to precisely and accurately measure ex vivo range of motion from cadaveric manipulations. The workflow for these studies is holistically similar to the in vivo XROMM workflow but presents several unique challenges. This paper aims to serve as a practical guide by walking through each step of the ex vivo XROMM process: how to acquire and prepare cadaveric specimens, how to manipulate specimens to collect X-ray data, and how to use these data to compute joint rotational mobility. Along the way, it offers recommendations for best practices and for avoiding common pitfalls to ensure a successful study.
Collapse
Affiliation(s)
- Armita R Manafzadeh
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| |
Collapse
|
28
|
Conconi M, Sancisi N, Parenti-Castelli V. Prediction of Individual Knee Kinematics From an MRI Representation of the Articular Surfaces. IEEE Trans Biomed Eng 2020; 68:1084-1092. [PMID: 32816671 DOI: 10.1109/tbme.2020.3018113] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The knowledge of individual joint motion may help to understand the articular physiology and to design better treatments and medical devices. Measurements of in-vivo individual motion are nowadays invasive/ionizing (fluoroscopy) or imprecise (skin markers). We propose a new approach to derive the individual knee natural motion from a three-dimensional representation of articular surfaces. METHODS We hypothesize that tissue adaptation shapes articular surfaces to optimize load distribution. Thus, the knee natural motion is obtained as the envelope of tibiofemoral positions and orientations that minimize peak contact pressure, i.e. that maximize joint congruence. We investigated four in-vitro and one in-vivo knees. Articular surfaces were reconstructed from a reference MRI. Natural motion was computed by congruence maximization and results were validated versus experimental data, acquired through bone implanted markers, in-vitro, and single-plane fluoroscopy, in-vivo. RESULTS In two cases, one of which in-vivo, maximum mean absolute error stays below 2.2° and 2.7 mm for rotations and translations, respectively. The remaining knees showed differences in joint internal rotation between the reference MRI and experimental motion at 0° flexion, possibly due to some laxity. The same difference is found in the model predictions, which, however, still replicate the individual knee motion. CONCLUSION The proposed approach allows the prediction of individual joint motion based on non-ionizing MRI data. SIGNIFICANCE This method may help to characterize healthy and, by comparison, pathological knee behavior. Moreover, it may provide an individual reference motion for the personalization of musculoskeletal models, opening the way to their clinical application.
Collapse
|
29
|
Akhbari B, Morton AM, Shah KN, Molino J, Moore DC, Weiss APC, Wolfe SW, Crisco JJ. Proximal-distal shift of the center of rotation in a total wrist arthroplasty is more than twice of the healthy wrist. J Orthop Res 2020; 38:1575-1586. [PMID: 32401391 PMCID: PMC7336861 DOI: 10.1002/jor.24717] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 03/02/2020] [Accepted: 05/08/2020] [Indexed: 02/04/2023]
Abstract
Reproduction of healthy wrist biomechanics should minimize the abnormal joint forces that could potentially result in the failure of a total wrist arthroplasty (TWA). To date, the in vivo kinematics of TWA have not been measured and it is unknown if TWA preserves healthy wrist kinematics. Therefore, the purpose of this in vivo study was to determine the center of rotation (COR) for a current TWA design and to compare its location to the healthy wrist. The wrist COR for six patients with TWA and 10 healthy subjects were calculated using biplane videoradiography as the subjects performed various range-of-motion and functional tasks that included coupled wrist motions. An open-source registration software, Autoscoper, was used for model-based tracking and kinematics analysis. It was demonstrated that the COR was located near the centers of curvatures of the carpal component for the anatomical motions of flexion-extension and radial-ulnar deviation. When compared to healthy wrists, the COR of TWAs was located more distal in both pure radial deviation (P < .0001) and pure ulnar deviation (P = .07), while there was no difference in its location in pure flexion or extension (P = .99). Across all coupled motions, the TWA's COR shifted more than two times that of the healthy wrists in the proximal-distal direction (17.1 vs 7.2 mm). We postulate that the mismatch in the COR location and behavior may be associated with increased loading of the TWA components, leading to an increase in the risk of component and/or interface failure.
Collapse
Affiliation(s)
- Bardiya Akhbari
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI 02912
| | - Amy M. Morton
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903
| | - Kalpit N. Shah
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903
| | - Janine Molino
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903
| | - Douglas C. Moore
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903
| | - Arnold-Peter C. Weiss
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903
| | - Scott W. Wolfe
- Hand and Upper Extremity Center, Hospital for Special Surgery, New York, NY 10021,Weill Medical College of Cornell University, New York, NY 10021
| | - Joseph J. Crisco
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI 02912,Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02903
| |
Collapse
|
30
|
Chow JCK, Boyd SK, Lichti DD, Ronsky JL. Robust Self-Supervised Learning of Deterministic Errors in Single-Plane (Monoplanar) and Dual-Plane (Biplanar) X-Ray Fluoroscopy. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:2051-2060. [PMID: 31902759 DOI: 10.1109/tmi.2019.2963446] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Fluoroscopic imaging that captures X-ray images at video framerates is advantageous for guiding catheter insertions by vascular surgeons and interventional radiologists. Visualizing the dynamical movements non-invasively allows complex surgical procedures to be performed with less trauma to the patient. To improve surgical precision, endovascular procedures can benefit from more accurate fluoroscopy data via calibration. This paper presents a robust self-calibration algorithm suitable for single-plane and dual-plane fluoroscopy. A three-dimensional (3D) target field was imaged by the fluoroscope in a strong geometric network configuration. The unknown 3D positions of targets and the fluoroscope pose were estimated simultaneously by maximizing the likelihood of the Student-t probability distribution function. A smoothed k-nearest-neighbour (kNN) regression is then used to model the deterministic component of the image reprojection error of the robust bundle adjustment. The Maximum Likelihood Estimation step and the kNN regression step are then repeated iteratively until convergence. Four different error modeling schemes were compared while varying the quantity of training images. It was found that using a smoothed kNN regression can automatically model the systematic errors in fluoroscopy with similar accuracy as a human expert using a small training dataset. When all training images were used, the 3D mapping error was reduced from 0.61-0.83 mm to 0.04 mm post-calibration (94.2-95.7% improvement), and the 2D reprojection error was reduced from 1.17-1.31 to 0.20-0.21 pixels (83.2-83.8% improvement). When using biplanar fluoroscopy, the 3D measurement accuracy of the system improved from 0.60 mm to 0.32 mm (47.2% improvement).
Collapse
|
31
|
Abstract
PURPOSE OF REVIEW The patellofemoral joint is a complicated articulation of the patella and femur that is prone to pathologies. The purpose of this review is to report on the current methods of investigating patellofemoral mechanics, factors that affect joint function, and future directions in patellofemoral joint research with emerging technologies and techniques. RECENT FINDINGS While previous hypotheses have suggested that the patella is only a moment arm extender, recent literature has suggested that the patella influences the control of knee moments and forces acting on the tibia as well as contributes to various aspects of patellar function with minimal neural input. With advancements in simulating a six-degrees-of-freedom patellofemoral joint, we have gained a better understanding of patella motion and have shown that geometry and muscle activations impact patella mechanics. Research into influences on patella mechanics from other joints such as the hip and foot has become more prevalent. In this review, we report current in vivo, in vitro, and in silico approaches to studying the patellofemoral joint. Kinematic and anatomical factors that affect patellofemoral joint function such as patella alta and tilt or bone morphology and ligaments are discussed. Moving forward, we suggest that advanced in vivo dynamic imaging methods coupled to musculoskeletal simulation will provide further understanding of patellofemoral pathomechanics and allow engineers and clinicians to design interventions to mitigate or prevent patellofemoral pathologies.
Collapse
|
32
|
Walker JD, Pirschel F, Gidmark N, MacLean JN, Hatsopoulos NG. A platform for semiautomated voluntary training of common marmosets for behavioral neuroscience. J Neurophysiol 2020; 123:1420-1426. [PMID: 32130092 PMCID: PMC7191516 DOI: 10.1152/jn.00300.2019] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 02/28/2020] [Accepted: 02/28/2020] [Indexed: 01/31/2023] Open
Abstract
Generally behavioral neuroscience studies of the common marmoset employ adaptations of well-established training methods used with macaque monkeys. However, in many cases these approaches do not readily generalize to marmosets indicating a need for alternatives. Here we present the development of one such alternate: a platform for semiautomated, voluntary in-home cage behavioral training that allows for the study of naturalistic behaviors. We describe the design and production of a modular behavioral training apparatus using CAD software and digital fabrication. We demonstrate that this apparatus permits voluntary behavioral training and data collection throughout the marmoset's waking hours with little experimenter intervention. Furthermore, we demonstrate the use of this apparatus to reconstruct the kinematics of the marmoset's upper limb movement during natural foraging behavior.NEW & NOTEWORTHY The study of marmosets in neuroscience has grown rapidly and presents unique challenges. We address those challenges with an innovative platform for semiautomated, voluntary training that allows marmosets to train throughout their waking hours with minimal experimenter intervention. We describe the use of this platform to capture upper limb kinematics during foraging and to expand the opportunities for behavioral training beyond the limits of traditional training sessions. This flexible platform can easily incorporate other tasks.
Collapse
Affiliation(s)
- Jeffrey D Walker
- Committee on Computational Neuroscience, University of Chicago, Chicago, Illinois
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, Illinois
| | - Friederice Pirschel
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, Illinois
| | | | - Jason N MacLean
- Committee on Computational Neuroscience, University of Chicago, Chicago, Illinois
- Department of Neurobiology, University of Chicago, Chicago, Illinois
- Grossman Institute for Neuroscience, Quantitative Biology and Human Behavior, University of Chicago, Chicago, Illinois
| | - Nicholas G Hatsopoulos
- Committee on Computational Neuroscience, University of Chicago, Chicago, Illinois
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, Illinois
- Grossman Institute for Neuroscience, Quantitative Biology and Human Behavior, University of Chicago, Chicago, Illinois
| |
Collapse
|
33
|
Maharaj JN, Kessler S, Rainbow MJ, D'Andrea SE, Konow N, Kelly LA, Lichtwark GA. The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping. Front Bioeng Biotechnol 2020; 8:106. [PMID: 32211386 PMCID: PMC7075816 DOI: 10.3389/fbioe.2020.00106] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Accepted: 02/03/2020] [Indexed: 11/13/2022] Open
Abstract
The intricate motion of the small bones of the feet are critical for its diverse function. Accurately measuring the 3-dimensional (3D) motion of these bones has attracted much attention over the years and until recently, was limited to invasive techniques or quantification of functional segments using multi-segment foot models. Biplanar videoradiography and model-based scientific rotoscoping offers an exciting alternative that allows us to focus on the intricate motion of individual bones in the foot. However, scientific rotoscoping, the process of rotating and translating a 3D bone model so that it aligns with the captured x-ray images, is either semi- or completely manual and it is unknown how much human error affects tracking results. Thus, the aim of this study was to quantify the inter- and intra-operator reliability of manually rotoscoping in vivo bone motion of the tibia, talus, and calcaneus during running. Three-dimensional CT bone volumes and high-speed biplanar videoradiography images of the foot were acquired on six participants. The six-degree-of-freedom motions of the tibia, talus, and calcaneus were determined using a manual markerless registration algorithm. Two operators performed the tracking, and additionally, the first operator re-tracked all bones, to test for intra-operator effects. Mean RMS errors were 1.86 mm and 1.90° for intra-operator comparisons and 2.30 mm and 2.60° for inter-operator comparisons across all bones and planes. The moderate to strong similarity values indicate that tracking bones and joint kinematics between sessions and operators is reliable for running. These errors are likely acceptable for defining gross joint angles. However, this magnitude of error may limit the capacity to perform advanced analyses of joint interactions, particularly those that require precise (sub-millimeter) estimates of bone position and orientation. Optimizing the view and image quality of the biplanar videoradiography system as well as the automated tracking algorithms for rotoscoping bones in the foot are required to reduce these errors and the time burden associated with the manual processing.
Collapse
Affiliation(s)
- Jayishni N Maharaj
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Sarah Kessler
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Michael J Rainbow
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada
| | - Susan E D'Andrea
- Department of Orthopaedics, Brown University, Providence, RI, United States.,Department of Kinesiology, The University of Rhode Island, Kingston, RI, United States
| | - Nicolai Konow
- Department of Biological Science, University of Massachusetts, Lowell, MA, United States
| | - Luke A Kelly
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Glen A Lichtwark
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
34
|
Mozingo JD, Akbari-Shandiz M, Murthy NS, Van Straaten MG, Schueler BA, Holmes DR, McCollough CH, Zhao KD. Shoulder mechanical impingement risk associated with manual wheelchair tasks in individuals with spinal cord injury. Clin Biomech (Bristol, Avon) 2020; 71:221-229. [PMID: 32035338 PMCID: PMC7050284 DOI: 10.1016/j.clinbiomech.2019.10.017] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 10/11/2019] [Accepted: 10/17/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Most individuals with spinal cord injury who use manual wheelchairs experience shoulder pain related to wheelchair use, potentially in part from mechanical impingement of soft tissue structures within the subacromial space. There is evidence suggesting that scapula and humerus motion during certain wheelchair tasks occurs in directions that may reduce the subacromial space, but it hasn't been thoroughly characterized in this context. METHODS Shoulder motion was imaged and quantified during scapular plane elevation with/without handheld load, propulsion with/without added resistance, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury using biplane fluoroscopy and computed tomography. For each position, minimum distance between rotator cuff tendon insertions (infraspinatus, subscapularis, supraspinatus) and the coracoacromial arch was determined. Tendon thickness was measured with ultrasound, and impingement risk scores were defined for each task based on frequency and amount of tendon compression. FINDINGS Periods of impingement were identified during scapular plane elevation and propulsion but not during pressure reliefs in most participants. There was a significant effect of activity on impingement risk scores (P < 0.0001), with greatest impingement risk during scapular plane elevation followed by propulsion. Impingement risk scores were not significantly different between scapular plane elevation loading conditions (P = 0.202) or propulsion resistances (P = 0.223). The infraspinatus and supraspinatus tendons were both susceptible to impingement during scapular plane elevation (by acromion), whereas the supraspinatus was most susceptible during propulsion (by acromion and coracoacromial ligament). INTERPRETATION The occurrence of mechanical impingement during certain manual wheelchair tasks, even without increased load/resistance, demonstrates the importance of kinematics inherent to a task as a determinant of impingement. Frequency of and technique used to complete daily tasks should be carefully considered to reduce impingement risk, which may help preserve shoulder health long-term.
Collapse
Affiliation(s)
- Joseph D Mozingo
- Biomedical Engineering and Physiology Graduate Program, Mayo Clinic Graduate School of Biomedical Sciences, USA; Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, USA
| | | | | | | | | | - David R Holmes
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | | | - Kristin D Zhao
- Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
35
|
Brocklehurst RJ, Moritz S, Codd J, Sellers WI, Brainerd EL. XROMM kinematics of ventilation in wild turkeys ( Meleagris gallopavo). ACTA ACUST UNITED AC 2019; 222:jeb.209783. [PMID: 31704902 DOI: 10.1242/jeb.209783] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 10/30/2019] [Indexed: 12/17/2022]
Abstract
The avian ribcage is derived relative to other amniotes, and is hypothesised to be constrained in its movements during ventilation. The double-headed ribs form two articulations with the vertebrae, and are thought to rotate about a strict anatomical axis. However, this costovertebral joint constraint has not been demonstrated empirically and was not found in other taxa with double-headed ribs (i.e. crocodilians). Here, we used X-ray reconstruction of moving morphology (XROMM) to quantify rib rotation in wild turkeys (Meleagris gallopavo) during breathing. We demonstrate that, as predicted from anatomy, the ribs do rotate in a hinge-like manner about a single axis. There is also evidence for elliptical motion of the sternum, as has been reported in other taxa. The evolution of the avian ribcage is closely related to the co-evolution of ventilation and flight, and these results are important for how we model ventilation mechanics in living and fossil birds.
Collapse
Affiliation(s)
- Robert J Brocklehurst
- School of Earth and Environmental Sciences, University of Manchester, Manchester M13 9PT, UK
| | - Sabine Moritz
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA.,Department of Biology, Community College of Rhode Island, Warwick, RI 02886, USA
| | - Jonathan Codd
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester M13 9PT, UK
| | - William I Sellers
- School of Earth and Environmental Sciences, University of Manchester, Manchester M13 9PT, UK
| | - Elizabeth L Brainerd
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| |
Collapse
|
36
|
Tsai LC, Cooper E, Hetzendorfer K, Warren G, Chang YH, Willett N. Effects of treadmill running and limb immobilization on knee cartilage degeneration and locomotor joint kinematics in rats following knee meniscal transection. Osteoarthritis Cartilage 2019; 27:1851-1859. [PMID: 31437580 PMCID: PMC7576441 DOI: 10.1016/j.joca.2019.08.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 07/25/2019] [Accepted: 08/07/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE This study examined the effects of reduced and elevated weight bearing on post-traumatic osteoarthritis (PTOA) development, locomotor joint kinematics, and degree of voluntary activity in rats following medial meniscal transection (MMT). DESIGN Twenty-one adult rats were subjected to MMT surgery of the left hindlimb and then assigned to one of three groups: (1) regular (i.e., no intervention), (2) hindlimb immobilization, or (3) treadmill running. Sham surgery was performed in four additional rats. Voluntary wheel run time/distance was measured, and 3D hindlimb kinematics were quantified during treadmill locomotion using biplanar radiography. Rats were euthanized 8 weeks after MMT or sham surgery, and the microstructure of the tibial cartilage and subchondral bone was quantified using contrast enhanced micro-CT. RESULTS All three MMT groups showed signs of PTOA (full-thickness lesions and/or increased cartilage volume) compared to the sham group, however the regular and treadmill-running groups had greater osteophyte formation than the immobilization group. For the immobilization group, increased volume was only observed in the anterior region of the cartilage. The treadmill-running group demonstrated a greater knee varus angle at mid-stance than the sham group, while the immobilization group demonstrated greater reduction in voluntary running than all the other groups at 2 weeks post-surgery. CONCLUSIONS Elevated weight-bearing via treadmill running at a slow/moderate speed did not accelerate PTOA in MMT rats when compared to regular weight-bearing. Reduced weight-bearing via immobilization may attenuate overall PTOA but still resulted in regional cartilage degeneration. Overall, there were minimal differences in hindlimb kinematics and voluntary running between MMT and sham rats.
Collapse
Affiliation(s)
- L.-C. Tsai
- Georgia State University, Atlanta, GA, USA,Address correspondence and reprint requests to: L.-C. Tsai, Department of Physical Therapy, Georgia State University, Atlanta, GA, USA. Tel: 404-413-1246. (L.-C. Tsai)
| | - E.S. Cooper
- Emory University, Atlanta, GA, USA,Georgia Institute of Technology, Atlanta, GA, USA
| | | | - G.L. Warren
- Georgia State University, Atlanta, GA, USA,Georgia Institute of Technology, Atlanta, GA, USA
| | - Y.-H. Chang
- Georgia Institute of Technology, Atlanta, GA, USA
| | - N.J. Willett
- Emory University, Atlanta, GA, USA,Georgia Institute of Technology, Atlanta, GA, USA,Atlanta VA Medical Center, Atlanta, GA, USA
| |
Collapse
|
37
|
Abstract
The wrist is a complex joint involving many small bones and complicated kinematics. It has, therefore, been traditionally difficult to image and ascertain information about kinematics when making a diagnosis. Although MRI and fluoroscopy have been used, they both have limitations. Recently, there has been interest in the use of 4D-CT in imaging the wrist. This review examines the literature regarding the use of 4D-CT in imaging the wrist to assess kinematics and its ability to diagnose pathology. Some questions remain about the description of normal ranges, the most appropriate method of measuring intercarpal stability, the accuracy compared with established standards, and the place of 4D-CT in postoperative assessment. Cite this article: Bone Joint J 2019;101-B:1325–1330.
Collapse
Affiliation(s)
- Jordy White
- University of Queensland, St Lucia, Australia
| | - Greg Couzens
- Brisbane Hand and Upper Limb Research Institute, Spring Hill, Australia
- Princess Alexandra Hospital, Brisbane, Australia
- Field Orthopaedics Research Group, Spring Hill, Australia
| | - Chris Jeffery
- Princess Alexandra Hospital, Brisbane, Australia
- Field Orthopaedics Research Group, Spring Hill, Queensland, Australia
| |
Collapse
|
38
|
Kessler SE, Rainbow MJ, Lichtwark GA, Cresswell AG, D'Andrea SE, Konow N, Kelly LA. A Direct Comparison of Biplanar Videoradiography and Optical Motion Capture for Foot and Ankle Kinematics. Front Bioeng Biotechnol 2019; 7:199. [PMID: 31508415 PMCID: PMC6716496 DOI: 10.3389/fbioe.2019.00199] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Accepted: 08/05/2019] [Indexed: 11/13/2022] Open
Abstract
Measuring motion of the human foot presents a unique challenge due to the large number of closely packed bones with congruent articulating surfaces. Optical motion capture (OMC) and multi-segment models can be used to infer foot motion, but might be affected by soft tissue artifact (STA). Biplanar videoradiography (BVR) is a relatively new tool that allows direct, non-invasive measurement of bone motion using high-speed, dynamic x-ray images to track individual bones. It is unknown whether OMC and BVR can be used interchangeably to analyse multi-segment foot motion. Therefore, the aim of this study was to determine the agreement in kinematic measures of dynamic activities. Nine healthy participants performed three walking and three running trials while BVR was recorded with synchronous OMC. Bone position and orientation was determined through manual scientific-rotoscoping. The OMC and BVR kinematics were co-registered to the same coordinate system, and BVR tracking was used to create virtual markers for comparison to OMC during dynamic trials. Root mean square (RMS) differences in marker positions and joint angles as well as a linear fit method (LFM) was used to compare the outputs of both methods. When comparing BVR and OMC, sagittal plane angles were in good agreement (ankle: R2 = 0.947, 0.939; Medial Longitudinal Arch (MLA) Angle: R2 = 0.713, 0.703, walking and running, respectively). When examining the ankle, there was a moderate agreement between the systems in the frontal plane (R2 = 0.322, 0.452, walking and running, respectively), with a weak to moderate correlation for the transverse plane (R2 = 0.178, 0.326, walking and running, respectively). However, root mean squared error (RMSE) showed angular errors ranging from 1.06 to 8.31° across the planes (frontal: 3.57°, 3.67°, transverse: 4.28°, 4.70°, sagittal: 2.45°, 2.67°, walking and running, respectively). Root mean square (RMS) differences between OMC and BVR marker trajectories were task dependent with the largest differences in the shank (6.0 ± 2.01 mm) for running, and metatarsals (3.97 ± 0.81 mm) for walking. Based on the results, we suggest BVR and OMC provide comparable solutions to foot motion in the sagittal plane, however, interpretations of out-of-plane movement should be made carefully.
Collapse
Affiliation(s)
- Sarah E Kessler
- Centre of Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Michael J Rainbow
- Skeletal Observation Laboratory, Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada
| | - Glen A Lichtwark
- Centre of Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Andrew G Cresswell
- Centre of Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Susan E D'Andrea
- Department of Orthopaedics, Brown University, Providence, RI, United States.,Department of Kinesiology, University of Rhode Island, Kingston, RI, United States.,Providence VA Medical Center, Providence, RI, United States
| | - Nicolai Konow
- Department of Biological Science, University of Massachusetts, Lowell, MA, United States
| | - Luke A Kelly
- Centre of Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
39
|
Laurence-Chasen JD, Ramsay JB, Brainerd EL. Shearing overbite and asymmetrical jaw motions facilitate food breakdown in a freshwater stingray, Potamotrygon motoro. ACTA ACUST UNITED AC 2019; 222:222/13/jeb197681. [PMID: 31292213 DOI: 10.1242/jeb.197681] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 06/10/2019] [Indexed: 12/19/2022]
Abstract
Many species of fish process their prey with cyclic jaw motions that grossly resemble those seen in mammalian mastication, despite starkly different tooth and jaw morphologies. The degree of similarity between the processing behaviors of these disparate taxa has implications for our understanding of convergence in vertebrate feeding systems. Here, we used XROMM (X-ray reconstruction of moving morphology) to investigate prey processing behavior of Potamotrygon motoro, the ocellate river stingray, which has recently been found to employ asymmetrical, shearing jaw motions to break down its prey. We found that P. motoro modulates its feeding kinematics to produce two distinct types of chew cycles: compressive cycles and overbite cycles. The latter are characterized by over-rotation of the upper jaw relative to the lower jaw, past the expected occlusal limit, and higher levels of bilateral asymmetry as compared with compressive chews. We did not find evidence of the mediolateral shearing motions typical of mammalian mastication, but overbite cycles appear to shear the prey item between the upper and lower toothplates in a propalinal fashion. Additionally, comparison of hyomandibular and jaw motions demonstrates that the angular cartilages decouple jaw displacement from hyomandibular displacement in rostrocaudal and mediolateral directions. The multiple similarities between mammalian mastication and the dynamic processing behavior of P. motoro support the use of sub-family Potamotrygoninae as a model for studying evolutionary convergence of mastication-like processing.
Collapse
Affiliation(s)
- J D Laurence-Chasen
- Department of Organismal Biology and Anatomy, The University of Chicago, 1027 E 57th St, Chicago, IL 60637, USA .,Department of Ecology and Evolutionary Biology, Brown University, 80 Waterman Street, Providence, RI 02912, USA
| | - Jason B Ramsay
- Biology Department, Westfield State University, 577 Western Avenue, Westfield, MA 01086, USA
| | - Elizabeth L Brainerd
- Department of Ecology and Evolutionary Biology, Brown University, 80 Waterman Street, Providence, RI 02912, USA
| |
Collapse
|
40
|
Akhbari B, Morton AM, Moore DC, Weiss APC, Wolfe SW, Crisco JJ. Accuracy of biplane videoradiography for quantifying dynamic wrist kinematics. J Biomech 2019; 92:120-125. [PMID: 31174845 DOI: 10.1016/j.jbiomech.2019.05.040] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 04/26/2019] [Accepted: 05/26/2019] [Indexed: 10/26/2022]
Abstract
Accurately assessing the dynamic kinematics of the skeletal wrist could advance our understanding of the normal and pathological wrist. Biplane videoradiography (BVR) has allowed investigators to study dynamic activities in the knee, hip, and shoulder joint; however, currently, BVR has not been utilized for the wrist joint because of the challenges associated with imaging multiple overlapping bones. Therefore, our aim was to develop a BVR procedure and to quantify its accuracy for evaluation of wrist kinematics. BVR was performed on six cadaveric forearms for one neutral static and six dynamic tasks, including flexion-extension, radial-ulnar deviation, circumduction, pronation, supination, and hammering. Optical motion capture (OMC) served as the gold standard for assessing accuracy. We propose a feedforward tracking methodology, which uses a combined model of metacarpals (second and third) for initialization of the third metacarpal (MC3). BVR-calculated kinematic parameters were found to be consistent with the OMC-calculated parameters, and the BVR/OMC agreement had submillimeter and sub-degree biases in tracking individual bones as well as the overall joint's rotation and translation. All dynamic tasks (except pronation task) showed a limit of agreement within 1.5° for overall rotation, and within 1.3 mm for overall translations. Pronation task had a 2.1° and 1.4 mm limit of agreement for rotation and translation measurement. The poorest precision was achieved in calculating the pronation-supination angle, and radial-ulnar and volar-dorsal translational components, although they were sub-degree and submillimeter. The methodology described herein may assist those interested in examining the complexities of skeletal wrist function during dynamic tasks.
Collapse
Affiliation(s)
- Bardiya Akhbari
- Department of Biomedical Engineering, Brown University, Providence, RI 02912, United States
| | - Amy M Morton
- Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912, United States
| | - Douglas C Moore
- Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912, United States
| | - Arnold-Peter C Weiss
- Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912, United States
| | - Scott W Wolfe
- Hand and Upper Extremity Center, Hospital for Special Surgery, New York, NY 10021, United States
| | - Joseph J Crisco
- Department of Biomedical Engineering, Brown University, Providence, RI 02912, United States; Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912, United States.
| |
Collapse
|
41
|
Koo YJ, Koo S. Three-Dimensional Kinematic Coupling of the Healthy Knee During Treadmill Walking. J Biomech Eng 2019; 141:2732256. [DOI: 10.1115/1.4043562] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Indexed: 11/08/2022]
Abstract
Accurate joint kinematics plays an important role in estimating joint kinetics in musculoskeletal simulations. Biplanar fluoroscopic (BPF) systems have been introduced to measure skeletal kinematics with six degrees-of-freedom. The purpose of this study was to model knee kinematic coupling using knee kinematics during walking, as measured by the BPF system. Seven healthy individuals (mean age, 23 ± 2 yr) performed treadmill walking trials at 1.2 m/s. Knee kinematics was regressed separately for the swing and stance phases using a generalized mixed effects model. Tibial anterior translation function was y=0.20x−3.09 for the swing phase and y=0.31x−0.54 for the stance phase, where x was the flexion angle and y was the tibial anterior translation. Tibial lateral and inferior translation were also regressed separately for the stance phase and the swing phase. Tibial external rotation was y=−0.002x2+0.19x−0.64 for the swing phase and y=−0.19x−1.22 for the stance phase. The tibial adduction rotation function was also calculated separately for the stance and swing phase. The study presented three-dimensional coupled motion in the knee during the stance and swing phases of walking, and demonstrated the lateral pivoting motion found in previous studies. This expanded understanding of secondary knee motion functions will benefit musculoskeletal simulation and help improve the accuracy of calculated kinetics.
Collapse
Affiliation(s)
- Young-Jun Koo
- School of Mechanical Engineering, Chung-Ang University, Seoul 06974, South Korea
| | - Seungbum Koo
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea e-mail:
| |
Collapse
|
42
|
In vivo assessment of the interaction of patellar tendon tibial shaft angle and anterior cruciate ligament elongation during flexion. J Biomech 2019; 90:123-127. [PMID: 31072596 DOI: 10.1016/j.jbiomech.2019.04.034] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 04/05/2019] [Accepted: 04/21/2019] [Indexed: 12/19/2022]
Abstract
A potential cause of non-contact anterior cruciate ligament (ACL) injury is landing on an extended knee. In line with this hypothesis, studies have shown that the ACL is elongated with decreasing knee flexion angle. Furthermore, at low flexion angles the patellar tendon is oriented to increase the anterior shear component of force acting on the tibia. This indicates that knee extension represents a position in which the ACL is taut, and thus may have an increased propensity for injury, particularly in the presence of excessive force acting via the patellar tendon. However, there is very little in vivo data to describe how patellar tendon orientation and ACL elongation interact during flexion. Therefore, this study measured the patellar tendon tibial shaft angle (indicative of the relative magnitude of the shear component of force acting via the patellar tendon) and ACL length in vivo as subjects performed a quasi-static lunge at varying knee flexion angles. Spearman rho rank correlations within each individual revealed that flexion angles were inversely correlated to both ACL length (rho = -0.94 ± 0.07, mean ± standard deviation, p < 0.05) and patellar tendon tibial shaft angle (rho = -0.99 ± 0.01, p < 0.05). These findings indicate that when the knee is extended, the ACL is both elongated and the patellar tendon tibial shaft angle is increased, resulting in a relative increase in anterior shear force on the tibia acting via the patellar tendon. Therefore, these data support the hypothesis that landing with the knee in extension is a high risk scenario for ACL injury.
Collapse
|
43
|
Capano JG, Moritz S, Cieri RL, Reveret L, Brainerd EL. Rib Motions Don't Completely Hinge on Joint Design: Costal Joint Anatomy and Ventilatory Kinematics in a Teiid Lizard, Salvator merianae. Integr Org Biol 2019; 1:oby004. [PMID: 33791512 PMCID: PMC7780499 DOI: 10.1093/iob/oby004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Rib rotations contribute to lung ventilation in most extant amniotes. These rotations are typically described as bucket-handle rotation about a dorsoventral axis, caliper rotation about a craniocaudal axis, and pump-handle rotation about a mediolateral axis. A synapomorphy for Lepidosauria is single-headed costovertebral articulations derived from the ancestral double-headed articulations of most amniotes. With a single articular surface, the costovertebral joints of squamates have the potential to rotate with three degrees-of-freedom (DOFs), but considerable variation exists in joint shape. We compared the costovertebral morphology of the Argentine black and white tegu, Salvator merianae, with the green iguana, Iguana iguana, and found that the costovertebral articulations of I. iguana were hemispherical, while those of S. merianae were dorsoventrally elongated and hemiellipsoidal. We predicted that the elongate joints in S. merianae would permit bucket-handle rotations while restricting caliper and pump-handle rotations, relative to the rounded joints of I. iguana. We used X-ray reconstruction of moving morphology to quantify rib rotations during breathing in S. merianae for comparison with prior work in I. iguana. Consistent with our hypothesis, we found less caliper motion in S. merianae than in I. iguana, but unexpectedly found similar pump-handle magnitudes in each species. The dorsoventrally elongate costovertebral morphology of S. merianae may provide passive rib support to reduce the conflict between locomotion and ventilation. Moreover, the observation of multiple DOFs during rib rotations in both species suggests that permissive costovertebral morphology may be more related to the biological roles of ribs outside of ventilation and help explain the evolution of this trait.
Collapse
Affiliation(s)
- J G Capano
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02906, USA
| | - S Moritz
- Department of Biology, Community College of Rhode Island, Warwick, RI 02886, USA
| | - R L Cieri
- School of Biological Sciences, University of Utah, Salt Lake City, UT 84112, USA
| | - L Reveret
- Inria Grenoble Rhone Alpes, 655 Avenue de l'Europe, 38330 Montbonnot-Saint-Martin, France
| | - E L Brainerd
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02906, USA
| |
Collapse
|
44
|
Navacchia A, Hume DR, Rullkoetter PJ, Shelburne KB. A computationally efficient strategy to estimate muscle forces in a finite element musculoskeletal model of the lower limb. J Biomech 2018; 84:94-102. [PMID: 30616983 DOI: 10.1016/j.jbiomech.2018.12.020] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 12/01/2018] [Accepted: 12/12/2018] [Indexed: 11/19/2022]
Abstract
Concurrent multiscale simulation strategies are required in computational biomechanics to study the interdependence between body scales. However, detailed finite element models rarely include muscle recruitment due to the computational burden of both the finite element method and the optimization strategies widely used to estimate muscle forces. The aim of this study was twofold: first, to develop a computationally efficient muscle force prediction strategy based on proportional-integral-derivative (PID) controllers to track gait and chair rise experimental joint motion with a finite element musculoskeletal model of the lower limb, including a deformable knee representation with 12 degrees of freedom; and, second, to demonstrate that the inclusion of joint-level deformability affects muscle force estimation by using two different knee models and comparing muscle forces between the two solutions. The PID control strategy tracked experimental hip, knee, and ankle flexion/extension with root mean square errors below 1°, and estimated muscle, contact and ligament forces in good agreement with previous results and electromyography signals. Differences up to 11% and 20% in the vasti and biceps femoris forces, respectively, were observed between the two knee models, which might be attributed to a combination of differing joint contact geometry, ligament behavior, joint kinematics, and muscle moment arms. The tracking strategy developed in this study addressed the inevitable tradeoff between computational cost and model detail in musculoskeletal simulations and can be used with finite element musculoskeletal models to efficiently estimate the interdependence between muscle forces and tissue deformation.
Collapse
Affiliation(s)
- Alessandro Navacchia
- Dept. of Mechanical and Materials Engineering, The University of Denver, CO, USA; Dept. of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
| | - Donald R Hume
- Dept. of Mechanical and Materials Engineering, The University of Denver, CO, USA
| | - Paul J Rullkoetter
- Dept. of Mechanical and Materials Engineering, The University of Denver, CO, USA
| | - Kevin B Shelburne
- Dept. of Mechanical and Materials Engineering, The University of Denver, CO, USA
| |
Collapse
|
45
|
Weiss M, Hainke K, Grund S, Gerlach K, Mülling CKW, Geiger SM. Does the range of motion in the bovine interphalangeal joints change with flooring condition? A pilot study using biplane high-speed fluoroscopic kinematography. J Dairy Sci 2018; 102:1443-1456. [PMID: 30591344 DOI: 10.3168/jds.2018-14844] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Accepted: 11/03/2018] [Indexed: 11/19/2022]
Abstract
This study had 2 objectives. The first objective was to investigate motion patterns and the range of motion of the bovine proximal and distal interphalangeal joints on concrete during the stance phase. The second objective was to determine whether the range of motion and the locomotive stability of the interphalangeal joints differ on concrete and 3 different commercially available rubber mats (Karera, Kura, and Pedikura; Kraiburg Elastik GmbH & Co. KG, Tittmoning, Germany). Biplane high-speed fluoroscopic kinematography (72 ± 2.5 kV and 112.5 ± 12.5 mA, refresh rate 500 frames per second, shutter 0.5 ms) was applied to record 1 stance phase of the right forelimb of 2 Holstein Friesian heifers (15 mo old, 440 ± 10 kg; ± standard deviation) on each flooring. Three-dimensional digital animations were generated with a marker-supported manual animation technique based on the recordings and computer tomographic bone models. The mean maximum range of motion of each of the 4 interphalangeal joints in terms of flexion/extension, abduction/adduction, and internal/external rotation were calculated as well as the mean number of local extrema as a measure of stability during the stance phase. The main degree of freedom in all interphalangeal joints was flexion and extension with a range of motion of 17.7 to 25.9°. The second largest degree of freedom differed between abduction/adduction (7.7-10.0°) and internal/external rotation (6.5-9.6°) depending on the joint. Remarkably, although smaller, these extrasagittal directions still contribute to the overall motion to a considerable degree. In addition, the interphalangeal joints of the lateral digit showed a tendency to move less during the stance phase than their medial counterparts. Comparing concrete to the rubber mats, the interphalangeal joints tend to have to cover a larger range of motion on concrete with the exception of the distal interphalangeal joint in terms of flexion/extension. The unyielding surface of concrete seems to force the flexible parts of the animal-ground-interaction into extended motion. Furthermore, there tends to be more instability in all 3 degrees of freedom in all 4 joints on concrete, implying a greater effort of the soft tissues to achieve a balanced motion. Detailed biomechanical research contributes to the development of adequate flooring systems by evaluating the mechanical strain on claws and joints and working toward lameness prevention and thus animal welfare.
Collapse
Affiliation(s)
- M Weiss
- Institute of Veterinary Anatomy, Histology and Embryology, Leipzig University, D-04103 Leipzig, Germany
| | - K Hainke
- Institute of Veterinary Anatomy, Histology and Embryology, Leipzig University, D-04103 Leipzig, Germany
| | - S Grund
- Institute of Veterinary Anatomy, Histology and Embryology, Leipzig University, D-04103 Leipzig, Germany
| | - K Gerlach
- Department for Horses, Faculty of Veterinary Medicine, Leipzig University, D-04103 Leipzig, Germany
| | - C K W Mülling
- Institute of Veterinary Anatomy, Histology and Embryology, Leipzig University, D-04103 Leipzig, Germany
| | - S M Geiger
- Institute of Veterinary Anatomy, Histology and Embryology, Leipzig University, D-04103 Leipzig, Germany; Institute of Topographic Anatomy, University of Veterinary Medicine Vienna, A-1210 Vienna.
| |
Collapse
|
46
|
Cieri RL, Moritz S, Capano JG, Brainerd EL. Breathing with floating ribs: XROMM analysis of lung ventilation in savannah monitor lizards. ACTA ACUST UNITED AC 2018; 221:jeb.189449. [PMID: 30257921 DOI: 10.1242/jeb.189449] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Accepted: 09/20/2018] [Indexed: 11/20/2022]
Abstract
The structures and functions of the vertebrate lung and trunk are linked through the act of ventilation, but the connections between these structures and functions are poorly understood. We used X-ray reconstruction of moving morphology (XROMM) to measure rib kinematics during lung ventilation in three savannah monitor lizards (Varanus exanthematicus). All of the dorsal ribs, including the floating ribs, contributed to ventilation; the magnitude and kinematic pattern showed no detectable cranial-to-caudal gradient. The true ribs acted as two rigid bodies connected by flexible cartilage, with the vertebral rib and ventromedial shaft of each sternal rib remaining rigid and the cartilage between them forming a flexible intracostal joint. Rib rotations can be decomposed into bucket handle rotation around a dorsoventral axis, pump handle rotation around a mediolateral axis and caliper motion around a craniocaudal axis. Dorsal rib motion was dominated by roughly equal contributions of bucket and pump rotation in two individuals and by bucket rotation in the third individual. The recruitment of floating ribs during ventilation in monitor lizards is strikingly different from the situation in iguanas, where only the first few true ribs contribute to breathing. This difference may be related to the design of the pulmonary system and life history traits in these two species. Motion of the floating ribs may maximize ventilation of the caudally and ventrolaterally positioned compliant saccular chambers in the lungs of varanids, while restriction of ventilation to a few true ribs may maximize crypsis in iguanas.
Collapse
Affiliation(s)
- Robert L Cieri
- Department of Biology, University of Utah, Salt Lake City, UT 84112, USA
| | - Sabine Moritz
- Department of Biology, Community College of Rhode Island, Warwick, RI 02886, USA
| | - John G Capano
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| | - Elizabeth L Brainerd
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| |
Collapse
|
47
|
An interpolation technique to enable accurate three-dimensional joint kinematic analyses using asynchronous biplane fluoroscopy. Med Eng Phys 2018; 60:109-116. [PMID: 30098937 DOI: 10.1016/j.medengphy.2018.07.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 05/25/2018] [Accepted: 07/22/2018] [Indexed: 11/22/2022]
Abstract
Biplane 2D-3D model-based registration and radiostereometric analysis (RSA) approaches have been commonly used for measuring three-dimensional, in vivo joint kinematics. However, in clinical biplane systems, the x-ray images are acquired asynchronously, which introduces registration errors. The present study introduces an interpolation technique to reduce image registration error by generating synchronous fluoroscopy image estimates. A phantom study and cadaveric shoulder study were used to evaluate the level of improvement in image registration that could be obtained as a result of using our interpolation technique. Our phantom study results show that the interpolated bead tracking technique was in better agreement with the true bead positions than when asynchronous images were used alone. The overall RMS error of glenohumeral kinematics for interpolated biplane registration was reduced by 1.27 mm, 0.40 mm, and 0.47 mm in anterior-posterior, superior-inferior, and medial-lateral translation, respectively; and 0.47°, 0.67°, and 0.19° in ab-adduction, internal-external rotation and flexion-extension, respectively, compared to asynchronous registration. The interpolated biplane registration results were consistent with previously reported studies using custom synchronous biplane fluoroscopy technology. This approach will be particularly useful for improving the kinematic accuracy of high velocity activities when using clinical biplane fluoroscopes or two independent c-arms, which are available at a number of institutions.
Collapse
|
48
|
Hume DR, Kefala V, Harris MD, Shelburne KB. Comparison of Marker-Based and Stereo Radiography Knee Kinematics in Activities of Daily Living. Ann Biomed Eng 2018; 46:1806-1815. [PMID: 29948373 DOI: 10.1007/s10439-018-2068-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Accepted: 06/05/2018] [Indexed: 11/24/2022]
Abstract
Movement of the marker positions relative to the body segments obscures in vivo joint level motion. Alternatively, tracking bones from radiography images can provide precise motion of the bones at the knee but is impracticable for measurement of body segment motion. Consequently, researchers have combined marker-based knee flexion with kinematic splines to approximate the translations and rotations of the tibia relative to the femur. Yet, the accuracy of predicting six degree-of-freedom joint kinematics using kinematic splines has not been evaluated. The objectives of this study were to (1) compare knee kinematics measured with a marker-based motion capture system to kinematics acquired with high speed stereo radiography (HSSR) and describe the accuracy of marker-based motion to improve interpretation of results from these methods, and (2) use HSSR to define and evaluate a new set of knee joint kinematic splines based on the in vivo kinematics of a knee extension activity. Simultaneous measurements were recorded from eight healthy subjects using HSSR and marker-based motion capture. The marker positions were applied to three models of the lower extremity to calculate tibiofemoral kinematics and compared to kinematics acquired with HSSR. As demonstrated by normalized RMSE above 1.0, varus-valgus rotation (1.26), medial-lateral (1.26), anterior-posterior (2.03), and superior-inferior translations (4.39) were not accurately measured. Using kinematic splines improved predictions in varus-valgus (0.81) rotation, and medial-lateral (0.73), anterior-posterior (0.69), and superior-inferior (0.49) translations. Using splines to predict tibiofemoral kinematics as a function knee flexion can lead to improved accuracy over marker-based motion capture alone, however this technique was limited in reproducing subject-specific kinematics.
Collapse
Affiliation(s)
- Donald R Hume
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | - Vasiliki Kefala
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | - Michael D Harris
- Program in Physical of Therapy, Washington University School of Medicine, St. Louis, MO, USA.,Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, MO, USA
| | - Kevin B Shelburne
- Department of Mechanical and Materials Engineering, University of Denver, 2155 East Wesley, Denver, CO, 80210, USA.
| |
Collapse
|
49
|
Brocklehurst RJ, Moritz S, Codd J, Sellers WI, Brainerd EL. Rib kinematics during lung ventilation in the American alligator ( Alligator mississippiensis): an XROMM analysis. ACTA ACUST UNITED AC 2018; 220:3181-3190. [PMID: 28855323 PMCID: PMC5612015 DOI: 10.1242/jeb.156166] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Accepted: 06/15/2017] [Indexed: 11/20/2022]
Abstract
The current hypothesis regarding the mechanics of breathing in crocodylians is that the double-headed ribs, with both a capitulum and tuberculum, rotate about a constrained axis passing through the two articulations; moreover, this axis shifts in the caudal thoracic ribs, as the vertebral parapophysis moves from the centrum to the transverse process. Additionally, the ventral ribcage in crocodylians is thought to possess additional degrees of freedom through mobile intermediate ribs. In this study, X-ray reconstruction of moving morphology (XROMM) was used to quantify rib rotation during breathing in American alligators. Whilst costovertebral joint anatomy predicted overall patterns of motion across the ribcage (decreased bucket handle motion and increased calliper motion), there were significant deviations: anatomical axes overestimated pump handle motion and, generally, ribs in vivo rotate about all three body axes more equally than predicted. The intermediate ribs are mobile, with a high degree of rotation measured about the dorsal intracostal joints, especially in the more caudal ribs. Motion of the sternal ribs became increasingly complex caudally, owing to a combination of the movements of the vertebral and intermediate segments. As the crocodylian ribcage is sometimes used as a model for the ancestral archosaur, these results have important implications for how rib motion is reconstructed in fossil taxa, and illustrate the difficulties in reconstructing rib movement based on osteology alone. Summary: Using XROMM to test how well joint anatomy predicts rib motion during breathing in crocodylians, our best living model for the earliest archosaurs.
Collapse
Affiliation(s)
- Robert J Brocklehurst
- School of Earth and Environmental Sciences, University of Manchester, Manchester M13 9PT, UK
| | - Sabine Moritz
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| | - Jonathan Codd
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester M13 9PT, UK
| | - William I Sellers
- School of Earth and Environmental Sciences, University of Manchester, Manchester M13 9PT, UK
| | - Elizabeth L Brainerd
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| |
Collapse
|
50
|
Sheehan FT, Brainerd EL, Troy KL, Shefelbine SJ, Ronsky JL. Advancing quantitative techniques to improve understanding of the skeletal structure-function relationship. J Neuroeng Rehabil 2018; 15:25. [PMID: 29558970 PMCID: PMC5859431 DOI: 10.1186/s12984-018-0368-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Accepted: 03/07/2018] [Indexed: 12/13/2022] Open
Abstract
Although all functional movement arises from the interplay between the neurological, skeletal, and muscular systems, it is the skeletal system that forms the basic framework for functional movement. Central to understanding human neuromuscular development, along with the genesis of musculoskeletal pathologies, is quantifying how the human skeletal system adapts and mal-adapts to its mechanical environment. Advancing this understanding is hampered by an inability to directly and non-invasively measure in vivo strains, stresses, and forces on bone. Thus, we traditionally have turned to animal models to garner such information. These models enable direct in vivo measures that are not available for human subjects, providing information in regards to both skeletal adaptation and the interplay between the skeletal and muscular systems. Recently, there has been an explosion of new imaging and modeling techniques providing non-invasive, in vivo measures and estimates of skeletal form and function that have long been missing. Combining multiple modalities and techniques has proven to be one of our most valuable resources in enhancing our understanding of the form-function relationship of the human skeletal, muscular, and neurological systems. Thus, to continue advancing our knowledge of the structural-functional relationship, validation of current tools is needed, while development is required to limit the deficiencies in these tools and develop new ones.
Collapse
Affiliation(s)
| | | | - Karen L Troy
- Worcester Polytechnic Institute, Worcester, MA, USA
| | | | | |
Collapse
|