Xie Y, Zhu Y, Shi Y, Zhao Y, Zhang H, Li F, Song H, Chen L, Guo W. Impact of Cross-Limb Stent-Graft Configuration on Hemodynamics in Abdominal Aortic Aneurysm Interventional Therapy. Cardiovasc Eng Technol 2024; 15:137-146. [PMID: 37985614 DOI: 10.1007/s13239-023-00702-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Accepted: 11/07/2023] [Indexed: 11/22/2023]
Abstract
PURPOSE The cross-limb (CL) technique is a commonly used endovascular treatment for addressing unfavorable anatomical features in patients with abdominal aortic aneurysm (AAA). The configuration of CL stent-graft plays a critical role in determining the postoperative hemodynamic properties and physiological behaviors, which ultimately impact the efficacy and safety of endovascular AAA treatment. This study aims to investigate the relationship between hemodynamics and CL stent-graft configuration from a hemodynamic perspective. METHODS Five distinct geometric models of cross-limb (CL) stent-graft configurations were constructed by optimizing the real clinical computed tomography angiography (CTA) data. These models varied in main body lengths and cross angles and were used to perform numerical simulations to analyze various hemodynamic parameters. Flow pattern, distribution of wall shear stress (WSS)-related parameters, localized normalized helicity (LNH), pressure drop, and the displacement force of all models were examined in this paper. RESULTS In patient-specific cases, helical flow and WSS increase with the main body. However, it also generated secondary flow in localized areas, leading to increased oscillation in the WSS direction. Notably, increasing the stent graft's main body length or decreasing the cross angle reduced the displacement force exerted on the stent-graft. Reducing the cross angle did not significantly alter the hemodynamic characteristics. CONCLUSION In the clinical practice of CL deployment, it is crucial to carefully consider the stent-graft configuration and the patient specific to achieve optimal postoperative outcomes. This study provides valuable insights for guiding stent selection and treatment planning in patients with abdominal aortic aneurysm undergoing CL techniques, from a hemodynamic perspective.
Collapse
Affiliation(s)
- Yanqing Xie
- Department of Cardiology, The First Affiliated Hospital of Ningbo University, Ningbo, 315020, China
| | - Yating Zhu
- Department of Vascular Surgery, First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853, China
| | - Yike Shi
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Yawei Zhao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Hongpeng Zhang
- Department of Vascular Surgery, First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853, China
| | - Fen Li
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, 79 West Yingze Street, Taiyuan, 030024, China.
| | - Hui Song
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, 79 West Yingze Street, Taiyuan, 030024, China
| | - Lingfeng Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Wei Guo
- Department of Vascular Surgery, First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853, China.
| |
Collapse
|
2
|
Tzirakis K, Kontopodis N, Ioannou CV. A hemodynamic study of blood flow models on various stent graft configurations during aorto-iliac reconstruction. Clin Hemorheol Microcirc 2024; 87:199-219. [PMID: 38363603 DOI: 10.3233/ch-232058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
PURPOSE To compare the hemodynamic performance of three (Bottom Up non-ballet, Top-Down non-ballet, Top Down ballet) idealized stent graft configurations used during endovascular repair of abdominal aortic aneurysms, under the influence of various rheological models. METHODS Ten rheological models are assumed and a commercial finite volume solver is employed for the simulation of blood flow under realistic boundary conditions. An appropriate mesh convergence study is performed and five hemodynamic variables are computed: the time average wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), endothelial cell activation potential (ECAP) and displacement force (DF) for all three configurations. RESULTS The choice of blood flow model may affect results, but does not constitute a significant determinant on the overall performance of the assumed stent grafts. On the contrary, stent graft geometry has a major effect. Specifically, the Bottom Up non-ballet type is characterized by the least favorable performance presenting the lowest TAWSS and the highest OSI, RRT and ECAP values. On the other hand, the Top Down ballet type presents hemodynamic advantages yielding the highest TAWSS and lowest OSI, RRT and ECAP average values. Furthermore, the ballet type is characterized by the lowest DF, although differences observed are small and their clinical relevance uncertain. CONCLUSIONS The effect of the assumed rheological model on the overall performance of the grafts is not significant. It is thus relatively safe to claim that it is the type of stent graft that determines its overall performance rather than the adopted blood flow model.
Collapse
Affiliation(s)
- Konstantinos Tzirakis
- Department of Mechanical Engineering, School of Engineering, Hellenic Mediterranean University, Heraklion, Crete, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Department, Medical School, University of Crete, Heraklion, Crete, Greece
| | - Christos V Ioannou
- Vascular Surgery Department, Medical School, University of Crete, Heraklion, Crete, Greece
| |
Collapse
|
3
|
Sena G, Montemurro R, Pezzo F, Gioffrè R, Gallelli G, Rubino P. Contralateral Snare Cannulation vs. Retrograde Gate Cannulation during Endovascular Aortic Repair in Difficult Iliac Artery Anatomy: A Single Center Experience. J Clin Med 2023; 13:175. [PMID: 38202182 PMCID: PMC10780168 DOI: 10.3390/jcm13010175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 12/01/2023] [Accepted: 12/26/2023] [Indexed: 01/12/2024] Open
Abstract
OBJECTIVE Endovascular aneurysm repair is well established as the gold standard in treating abdominal aortic aneurysms. Generally, endovascular repair is performed using a bi or trimodular stent graft, requiring placement of a contralateral iliac limb. Deployment of the contralateral iliac limb requires retrograde gate cannulation of the endograft main body contralateral limb. This step represents the crucial point of a standard endovascular repair procedure and can become challenging, especially in the case of high iliac tortuosity. This study compares the procedural times between the retrograde gate cannulation and the contralateral snare cannulation to demonstrate the possibility of directly performing the contralateral snare cannulation in the case of a complex iliac anatomy assessed by the iliac tortuosity index. METHODS One hundred and forty-eight patients with infrarenal abdominal aortic aneurysms who underwent endovascular aneurysm repair from 2017 to 2022 were analyzed retrospectively. Cannulation times between retrograde gate cannulation and contralateral snare cannulation were compared for each degree of iliac tortuosity. The degree of iliac tortuosity was assessed through the iliac tortuosity index. Cannulation times were detected from inserting the wire into the introducer to passing through the radio-opaque gate markers. RESULTS The cannulation times were 2.94 min for the retrograde gate cannulation group and 3.15 min for the contralateral snare cannulation group, respectively, with no statistically significant differences (p = 0.33). Overall cannulation times were 2.98 min. For the iliac tortuosity index grade 0, the cannulation times were 2.71 min for the retrograde gate cannulation group and 3.85 min for the contralateral snare cannulation group, respectively, with a significant difference in favor of the retrograde gate cannulation group (p < 0.0001). For the iliac tortuosity index grade 1, the cannulation times were 2.74 min for the retrograde gate cannulation group and 2.8 min for the contralateral snare cannulation group, respectively, with no statistically significant differences (p = 0.63). Regarding the iliac tortuosity index grades 2 and 3, the cannulation times were 3.01 and 4.93 min for the retrograde gate cannulation group and 2.71 and 3.28 min for the contralateral snare cannulation group, respectively. The first group's times were significantly higher than the second group's (p = 0.01 and p = 0.0001). CONCLUSIONS In patients with infrarenal abdominal aortic aneurysms undergoing endovascular aortic repair, the gate cannulation times were significantly shorter for the contralateral snare cannulation method than the retrograde gate cannulation method in the iliac tortuosity index grades 2 and 3. Therefore, performing the contralateral snare cannulation method would be appropriate.
Collapse
Affiliation(s)
- Giuseppe Sena
- Department of Vascular Surgery, “Pugliese-Ciaccio” Hospital, 88100 Catanzaro, Italy; (R.M.); (F.P.); (R.G.); (G.G.); (P.R.)
| | | | | | | | | | | |
Collapse
|
4
|
Brand M, Yoel B, Eichler E, Speter C, Halak M, Marom G. The effect of stent graft curvature on the hemodynamic displacement force after abdominal aortic aneurysm endovascular repair. ROYAL SOCIETY OPEN SCIENCE 2023; 10:230563. [PMID: 37416831 PMCID: PMC10320339 DOI: 10.1098/rsos.230563] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 06/12/2023] [Indexed: 07/08/2023]
Abstract
Endovascular aortic aneurysm repair is a minimally invasive procedure with low mortality and morbidity. Clinical studies have revealed that a displacement force (DF) can cause stent graft (SG) migration in some circumstances requiring repeated intervention. This study aims to determine the relationship between the SG curvature and the calculated DF from four patient-specific computational fluid dynamics models. The SG's curvature was defined according to the centrelines of the implanted SG's branches. The centrelines were defined as either intersecting or separated lines. The centreline curvature (CLC) metrics were calculated based on the local curvature radii and the distances from the centrelines of idealized straight branches. The average CLC value and average variation were calculated to represent the entire graft's curvature. These CLC calculations were compared, and the method that gave the best correlation to the calculated DF was found. The optimal correlation is obtained from calculating the CLC average variation using separated centrelines and distance from straight lines, with an R2 = 0.89. Understanding the relationship between vascular morphology and DF can help identify at-risk patients before the procedure. In these cases, we can provide appropriate treatment and follow up with the patient to prevent future failure.
Collapse
Affiliation(s)
| | | | | | - Chen Speter
- Department of Vascular Surgery, The Chaim Sheba Medical Centre, Tel Hashomer, Israel
| | - Moshe Halak
- Department of Vascular Surgery, The Chaim Sheba Medical Centre, Tel Hashomer, Israel
| | - Gil Marom
- Tel Aviv University, Ramat Aviv, Tel Aviv, Israel
| |
Collapse
|
5
|
Shen Y, Wang J, Zhao J, Yuan D, Wang T, Huang B. DANCER: Study protocol of a prospective, non-randomized controlled trial for crossed limb versus standard limb configuration in endovascular abdominal aortic aneurysm repair. Front Cardiovasc Med 2022; 9:1046200. [DOI: 10.3389/fcvm.2022.1046200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Accepted: 10/27/2022] [Indexed: 11/10/2022] Open
Abstract
BackgroundHostile anatomy, especially severely angulated neck and tortuous iliac arteries, has always been a conundrum in endovascular aneurysm repair (EVAR). Crossed limb (CL) graft, also called the “ballerina technique,” has been utilized to address this problem by facilitating gate cannulation. In terms of short and long-term outcomes, correlated studies have made inconsistent conclusions and this issue remains controversial. Based on a previous cohort study conducted in our center, we aim to prospectively compare the safety and efficacy between CL and standard limb (SL) configuration in patients receiving EVAR.MethodsThis is a prospective, single-center, non-randomized controlled trial. A total of 275 patients who meet the inclusion criteria will be enrolled and allocated with a 4:11 ratio of CL to SL, which is based on results of our previous study. All patients will receive same perioperative management and postoperative medications. All EVAR procedures will be performed under standard protocol, utilizing Endurant II or IIs Stent Graft. The configuration of the graft stent will be decided by surgeons and confirmed by final angiography. The primary outcome is 3-year freedom from major adverse limb-graft events (MALEs). Endpoints will be assessed at the following time points: 1, 6, 12, 24, and 36 months.DiscussionTo our best knowledge, this crosseD vs. stANdard Configuration in Endovascular Repair (DANCER) trial is the first non-randomized controlled trial to compare these two graft configurations in EVAR. The main aim is to compare the MALEs between two groups at 3 years postoperatively. This trial will hopefully provide high-level evidence for employing CL in EVAR.Clinical trial registration[www.chictr.org.cn], identifier [ChiCTR2100053055].
Collapse
|
6
|
Qing M, Qiu Y, Wang J, Zheng T, Yuan D. A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck. Front Physiol 2021; 12:795085. [PMID: 34925075 PMCID: PMC8674644 DOI: 10.3389/fphys.2021.795085] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 11/10/2021] [Indexed: 02/05/2023] Open
Abstract
Objectives: Cross-limb stent grafts for endovascular aneurysm repair (EVAR) are often employed for abdominal aortic aneurysms (AAAs) with significant aortic neck angulation. Neck angulation may be coronal or sagittal; however, previous hemodynamic studies of cross-limb EVAR stent grafts (SGs) primarily utilized simplified planar neck geometries. This study examined the differences in flow patterns and hemodynamic parameters between crossed and non-crossed limb SGs at different spatial neck angulations. Methods: Ideal models consisting of 13 cross and 13 non-cross limbs were established, with coronal and sagittal angles ranging from 0 to 90°. Computational fluid dynamics (CFD) was used to capture the hemodynamic information, and the differences were compared. Results: With regards to the pressure drop index, the maximum difference caused by the configuration and angular direction was 4.6 and 8.0%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 27.1%. With regards to the SAR-TAWSS index, the maximum difference caused by the configuration and angular direction was 7.8 and 9.8%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 26.7%. In addition, when the aneurysm neck angle is lower than 45°, the configuration and angular direction significantly influence the OSI and helical flow intensity index. However, when the aneurysm neck angle is greater than 45°, the hemodynamic differences of each model at the same aneurysm neck angle are reduced. Conclusion: The main factor affecting the hemodynamic index was the angle of the aneurysm neck, while the configuration and angular direction had little effect on the hemodynamics. Furthermore, when the aneurysm neck was greatly angulated, the cross-limb technique did not increase the risk of thrombosis.
Collapse
Affiliation(s)
- Ming Qing
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,Yibin Institute of Industrial Technology/Sichuan University Yibin Park, Yibin, China
| | - Yue Qiu
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, China
| | - Jiarong Wang
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Tinghui Zheng
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,Med-X Center for Informatics, Sichuan University, Chengdu, China
| | - Ding Yuan
- West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, China.,Med-X Center for Informatics, Sichuan University, Chengdu, China
| |
Collapse
|
7
|
Ashraf F, Ambreen T, Park CW, Kim DI. Comparative evaluation of ballet-type and conventional stent graft configurations for endovascular aneurysm repair: A CFD analysis. Clin Hemorheol Microcirc 2021; 78:1-27. [PMID: 33459700 PMCID: PMC8293652 DOI: 10.3233/ch-200996] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE: Cross limb stent graft (SG) configuration technique for endovascular aneurysm repair (EVAR) is employed for splayed aortic bifurcations to avoid device kinking and smoothen cannulation. The present study investigates three types of stent graft (SG) configurations for endovascular aneurysm repair (EVAR) in abdominal aortic aneurysm. A computational fluid dynamic analysis was performed on the pulsatile non-Newtonian flow characteristics in three ideally modeled geometries of abdominal aortic (AA) SG configurations. METHODS: The three planar and crosslimb SG configurations were ideally modeled, namely, top-down nonballet-type, top-down ballet-type, and bottom-up nonballet-type configurations. In top-down SG configuration, most of the device is deployed in the main body in the vicinity of renal artery and the limbs are extended to the iliac artery. While in the bottom-up configuration, some of the SG device is deployed in the main body, the limbs are deployed in aortic bifurcation, and the extra stent graft of the main body is extended to the proximal aorta until the below of the renal artery. The effects of non-Newtonian pulsatile flow on the wall stresses and flow patterns of the three models were investigated and compared. Moreover, the average wall shear stress (AWSS), oscillatory shear stress index (OSI), absolute helicity, pressure distribution, graft displacement and flow visualization plots were analyzed. RESULTS: The top-down ballet-type showed less branch blockage effect than the top-down nonballet-type models. Furthermore, the top-down ballet-type configuration showed an increased tendency to sustain high WSS and higher helicity characteristics than that of the bottom-up and top-down non-ballet type configurations. However, displacement forces of the top-down ballet-type configuration were 40% and 9.6% higher than those of the bottom-up and top-down nonballet-type configurations, respectively. CONCLUSIONS: Some complications such as graft tearing, thrombus formation, limb disconnection during long term follow up periods might be relevant to hemodynamic characteristics according to the configurations of EVAR. Hence, the reported data required to be validated with the clinical results.
Collapse
Affiliation(s)
- Fahmida Ashraf
- School of Mechanical Engineering, Kyungpook National University, Daegu, South Korea
| | - Tehmina Ambreen
- School of Mechanical Engineering, Kyungpook National University, Daegu, South Korea
| | - Cheol Woo Park
- School of Mechanical Engineering, Kyungpook National University, Daegu, South Korea
| | - Dong-Ik Kim
- Division of Vascular Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, South Korea
| |
Collapse
|
8
|
Sultan S, Barrett N, Tawfick W, Parodi JC, Hynes N. Contemporary abdominal aortic aneurysm devices, three decades of research and development with big data. Why has the best graft not been produced yet? A missed opportunity. ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY 2019. [DOI: 10.23736/s1824-4777.19.01417-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
9
|
Raptis A, Xenos M, Spanos K, Kouvelos G, Giannoukas A, Matsagkas M. Endograft Specific Haemodynamics After Endovascular Aneurysm Repair: Flow Characteristics of Four Stent Graft Systems. Eur J Vasc Endovasc Surg 2019; 58:538-547. [PMID: 31431336 DOI: 10.1016/j.ejvs.2019.04.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 09/09/2018] [Accepted: 04/14/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVES The implication of haemodynamics in the occurrence of complications after endovascular aneurysm repair (EVAR) has been raised in the literature. Different aortic stent graft configurations may lead to different haemodynamic properties. The current study deals with the post-operative haemodynamic variability between four stent graft systems with different structure, material, and type of fixation. METHODS Computed tomography data of 32 patients were used, equally distributed among the four endograft groups, namely the AFX, Endurant, Excluder, and Nellix. Velocity, wall shear stress (WSS), and helicity statistics were calculated, in regions around the flow division where disturbances are expected. The haemodynamic data were compared between and within the groups. RESULTS The morphology of AAAs pre-operatively did not vary significantly among the four groups. Before the flow division, lowest velocity was observed in Endurant cases and highest in Nellix cases. Endurant induced the lowest peak WSS and Nellix the highest (p = .03). The helicity levels were low in AFX and Nellix cases and high in Endurant and Excluder cases. After the flow division, the trend in the results was preserved. Nellix induced the highest velocity and WSS, followed closely by Excluder and AFX. There was a significant increase of helicity before and after flow division in AFX (p <0.001, R2 = 0.09) and Nellix (p <0.001) cases. CONCLUSIONS It has been shown that different types of endografts induce variable haemodynamic conditions around the flow division. The parallel limb structure, featured by Nellix, seems to induce favourable flow conditions in terms of velocity and WSS, while helical flow before the flow division is suppressed. High WSS is generally considered to be a desirable flow characteristic in endovascular devices, whereas helicity extremes (very low or high) are potentially a negative sign. Endurant, with the stiffer material and the short neck structure, was associated with the lowest blood velocity and WSS values but preserved high helicity levels. The AFX and Excluder, which include the same material, induced similar haemodynamic conditions.
Collapse
Affiliation(s)
- Anastasios Raptis
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece
| | - Michalis Xenos
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Mathematics, University of Ioannina, Ioannina, Greece
| | - Konstantinos Spanos
- Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - George Kouvelos
- Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Athanasios Giannoukas
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Miltiadis Matsagkas
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece.
| |
Collapse
|
10
|
Algabri YA, Altwijri O, Chatpun S. Visualization of Blood Flow in AAA Patient-Specific Geometry: 3-D Reconstruction and Simulation Procedures. BIONANOSCIENCE 2019. [DOI: 10.1007/s12668-019-00662-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
11
|
Moulakakis KG, Kakisis J, Gonidaki E, Lazaris AM, Tsangaris S, Geroulakos G, Manopoulos C. Comparison of Fluid Dynamics Variations Between Chimney and Fenestrated Endografts for Pararenal Aneurysms Repair: A Patient Specific Computational Study as Motivation for Clinical Decision-Making. Vasc Endovascular Surg 2019; 53:572-582. [PMID: 31382837 DOI: 10.1177/1538574419867531] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND-AIM Limited data exist concerning the fluid dynamic changes induced by endovascular aortic repair with fenestrated and chimney graft modalities in pararenal aneurysms. We aimed to investigate and compare the wall shear stress (WSS) and flow dynamics for the branch vessels before and after endovascular aortic repair with fenestrated and chimney techniques. METHODS Modeling was done for patient specific pararenal aortic aneurysms employing fenestrated and chimney grafts (Materialise Mimics 10.0) before and after the endovascular procedure, using computed tomography scans of patients. Surface and spatial grids were created using the ANSYS CFD meshing software 2019 R2. Assessment of blood flow, streamlines, and WSS before and after aneurysm repair was performed. RESULTS The endovascular repair with chimney grafts leaded to a 43% to 53% reduction in perfusion in renal arteries. In fenestrated reconstruction, we observed a 15% reduced perfusion in both renal arteries. In both cases, we observed a decrease in the recirculation phenomena of the aorta after endovascular repair. Concerning the grafts of the renal arteries, we observed in both the transverse and longitudinal axes low WSS regions with simultaneous recirculation of the flow 1 cm distal to the ostium sites in both aortic graft models. High WSS regions appeared in the sites of ostium. CONCLUSIONS We observed reduced renal perfusion in chimney grafts compared to fenestrated grafts, probably caused by the long and kinked characteristics of these devices.
Collapse
Affiliation(s)
- Konstantinos G Moulakakis
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - John Kakisis
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Eleni Gonidaki
- 2 Biofluid Mechanics and Biomedical Engineering Laboratory, Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Greece
| | - Andreas M Lazaris
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Sokrates Tsangaris
- 2 Biofluid Mechanics and Biomedical Engineering Laboratory, Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Greece
| | - George Geroulakos
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Christos Manopoulos
- 2 Biofluid Mechanics and Biomedical Engineering Laboratory, Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Greece
| |
Collapse
|
12
|
Chen T, Lancaster M, Lin DSY, Doyle MG, Forbes TL, Amon CH. Measurement of Frictional Properties of Aortic Stent Grafts and Their Delivery Systems. J Med Device 2019. [DOI: 10.1115/1.4043292] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Stent grafts are medical devices used to treat abdominal aortic aneurysms (AAAs) in endovascular aneurysm repair (EVAR). Computational and experimental models have been developed to study stent graft delivery and deployment during EVAR; however, frictional properties have not been taken into account in most previous studies. The objective of this study was to determine the coefficients of friction of three commercially available stent grafts (Cook Zenith, Medtronic Endurant, and Vascutek Anaconda), their delivery sheaths, a porcine aorta, and two mock arterial materials. Stent grafts were obtained and separated into stents, graft fabric, and sheaths. Using a custom-made friction measurement apparatus, the coefficients of friction were measured between five material pairs: (i) the stents and inner surface of the sheath, (ii) the graft fabric and inner surface of the sheath, (iii) the outer surface of the sheath and a porcine aorta, (iv) the outer surface of the sheath and three different polyvinyl alcohol (PVA) cryogels, and (v) the outer surface of the sheath and a polydimethylsiloxane (PDMS) sheet. The results show that the coefficients of friction between the graft fabric and the sheath were higher than those between the stents and the sheath. The PVA cryogels showed more comparable frictional properties to the porcine aorta than did the PDMS sheet, suggesting that PVA cryogels provide a more accurate approximation for the in vivo frictional properties. These results can be used to improve the accuracy of computational models for stent graft delivery and deployment and to select appropriate materials for vascular phantoms.
Collapse
Affiliation(s)
- Tianhao Chen
- Division of Engineering Science, University of Toronto, 35 Street George Street, Toronto, ON M5S 1A4, Canada e-mail:
| | - Michael Lancaster
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada e-mail:
| | - Dawn S. Y. Lin
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada e-mail:
| | - Matthew G. Doyle
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network, University of Toronto, 200 Elizabeth Street, Eaton North 6-222, Toronto, ON M5G 2C4, Canada e-mail:
| | - Thomas L. Forbes
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network, University of Toronto, 200 Elizabeth Street, Eaton North 6-222, Toronto, ON M5G 2C4, Canada e-mail:
| | - Cristina H. Amon
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, ON M5S 3G8, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Rosebrugh Building, 164 College Street, Toronto, ON M5S3G9, Canada e-mail:
| |
Collapse
|
13
|
Computational study on hemodynamic changes in patient-specific proximal neck angulation of abdominal aortic aneurysm with time-varying velocity. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:181-190. [PMID: 30762222 DOI: 10.1007/s13246-019-00728-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Accepted: 01/21/2019] [Indexed: 12/27/2022]
Abstract
Aneurysms are considered as a critical cardiovascular disease worldwide when they rupture. The clinical understanding of geometrical impact on the flow behaviour and biomechanics of abdominal aortic aneurysm (AAA) is progressively developing. Proximal neck angulations of AAAs are believed to influence the hemodynamic changes and wall shear stress (WSS) within AAAs. Our aim was to perform pulsatile simulations using computational fluid dynamics (CFD) for patient-specific geometry to investigate the influence of severe angular (≥ 60°) neck on AAA's hemodynamic and wall shear stress. The patient's geometrical characteristics were obtained from a computed tomography images database of AAA patients. The AAA geometry was reconstructed using Mimics software. In computational method, blood was assumed Newtonian fluid and an inlet varying velocity waveform in a cardiac cycle was assigned. The CFD study was performed with ANSYS software. The results of flow behaviours indicated that the blood flow through severe bending of angular neck leads to high turbulence and asymmetry of flows within the aneurysm sac resulting in blood recirculation. The high wall shear stress (WSS) occurred near the AAA neck and on surface of aneurysm sac. This study explained and showed flow behaviours and WSS progression within high angular neck AAA and risk prediction of abdominal aorta rupture. We expect that the visualization of blood flow and hemodynamic changes resulted from CFD simulation could be as an extra tool to assist clinicians during a decision making when estimation the risks of interventional procedures.
Collapse
|
14
|
Numerical and Experimental Investigation of Novel Blended Bifurcated Stent Grafts with Taper to Improve Hemodynamic Performance. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2018; 2018:8054850. [PMID: 30271457 PMCID: PMC6151236 DOI: 10.1155/2018/8054850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 07/17/2018] [Accepted: 07/29/2018] [Indexed: 11/26/2022]
Abstract
The typical helical flow within the human arterial system is widely used when designing cardiovascular devices, as this helical flow can be generated using the “crossed limbs” strategy of the bifurcated stent graft (BSG) and enhanced by the tapered structure of arteries. Here, we propose the use of a deflected blended bifurcated stent graft (BBSG) with various tapers, using conventional blended BSGs with the same degree of taper as a comparison. Hemodynamic performances, including helical strength and wall shear stress- (WSS-) based indicators, were assessed. Displacement forces that may induce stent-graft migration were assessed using numerical simulations and in vitro experiments. The results showed that as the taper increased, the displacement force, helicity strength, and time-averaged wall shear stress (TAWSS) within the iliac grafts increased, whereas the oscillating shear index (OSI) and relative residence time (RRT) gradually decreased for both types of BBSGs. With identical tapers, deflected BBSGs, compared to conventional BBSGs, exhibited a wider helical structure and lower RRT on the iliac graft and lower displacement force; however, there were no differences in hemodynamic indicators. In summary, the presence of tapering facilitated helical flow and produced better hemodynamic performance but posed a higher risk of graft migration. Conventional and deflected BBSGs with taper might be the two optimal configurations for endovascular aneurysm repair, given the helical flow. The deflected BBSG provides a better configuration, compared to the conventional BBSG, when considering the reduction of migration risk.
Collapse
|
15
|
Numerical and Experimental Investigation of the Hemodynamic Performance of Bifurcated Stent Grafts with Various Torsion Angles. Sci Rep 2018; 8:12625. [PMID: 30135573 PMCID: PMC6105657 DOI: 10.1038/s41598-018-31015-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Accepted: 07/30/2018] [Indexed: 11/09/2022] Open
Abstract
The “crossed limbs” strategy for bifurcated stent grafts (BSGs) is widely employed when abdominal aortic aneurysm (AAA) patients have unfavorable neck or highly splayed iliac arteries. Helical flow is regarded as a typical flow pattern within the human arterial system and is believed to have the positive physiological effects of inhibiting thrombosis formation and atherosclerosis. The “crossed limbs” strategy may induce helical flow and improve the stent graft outcome. To verify the performance of this strategy by considering hemodynamics, we constructed a series of idealized BSGs with various torsion angles and evaluated the hemodynamic performance, including the helical strength, time-averaged wall shear stress (TAWSS), oscillatory shear index, relative resident time (RRT), and displacement force. Our numerical results indicate that an increased torsion angle enhances the helicity strength at the iliac outlets. However, with increasing torsion angle, the TAWSS in the iliac graft decreases and the RRT increases. In addition, our numerical simulations and in vitro experiments reveal that the displacement force increases gradually with increasing torsion angle. In summary, the “crossed limbs” strategy may have benefits for AAA treatment in terms of helical flow, but because of the unfavorable hemodynamic performance verified by analyzing the hemodynamic indicators, the risk of stent graft migration increases with increasing torsion angle. Therefore, the “crossed limbs” strategy should be carefully employed in surgical AAA treatment.
Collapse
|
16
|
Liu M, Sun A, Deng X. Hemodynamic performance within crossed stent grafts: computational and experimental study on the effect of cross position and angle. Biomed Eng Online 2018; 17:85. [PMID: 29921281 PMCID: PMC6009958 DOI: 10.1186/s12938-018-0517-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Accepted: 06/12/2018] [Indexed: 12/31/2022] Open
Abstract
Background and aims The crossed limbs stent graft technique is regularly employed to treat abdominal aortic aneurysm patients with unfavorable aneurysm necks or widely splayed common iliac arteries. This article numerically evaluates the hemodynamic performance of the crossed limbs strategy by analyzing numerical simulations and conducting experiments using two series of idealized bifurcated stent grafts with different cross angles and cross positions. Results Results demonstrated that the absolute helicity at outlets decreased with increased cross angles and increased with decreased cross positions. The time-averaged wall shear stress remained approximately unchanged, whereas the oscillating shear index and relative resident time decreased slightly when the cross angle increased and cross position decreased in iliac grafts. Additionally, both numerical and in vitro experimental results indicate the displacement force acting on the stent graft gradually increased as cross angles increased and cross positions decreased. Results further indicated that strip areas with a high oscillating shear index and high relative resident time, which may be vulnerable to thrombosis formation, exist along the outer surface of the iliac artery grafts. Conclusion Given this information, the optimal crossed limbs configuration may contain a small cross angle and low cross position; however, low cross positions may increase the risk of migration.
Collapse
Affiliation(s)
- Ming Liu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science & Medical Engineering, Beihang University, Beijing, 100083, China
| | - Anqiang Sun
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science & Medical Engineering, Beihang University, Beijing, 100083, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, 102402, China
| | - Xiaoyan Deng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science & Medical Engineering, Beihang University, Beijing, 100083, China. .,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, 102402, China.
| |
Collapse
|
17
|
Sanford RM, Crawford SA, Genis H, Doyle MG, Forbes TL, Amon CH. Predicting Rotation in Fenestrated Endovascular Aneurysm Repair Using Finite Element Analysis. J Biomech Eng 2018; 140:2681000. [DOI: 10.1115/1.4040124] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Indexed: 01/20/2023]
Abstract
Fenestrated endovascular aneurysm repair (FEVAR) is a minimally invasive method of abdominal aortic aneurysm (AAA) repair utilized in patients with complex vessel anatomies. Stent grafts (SG) used in this process contain fenestrations within the device that need to be aligned with the visceral arteries upon successful SG deployment. Proper alignment is crucial to maintain blood flow to these arteries and avoid surgical complications. During fenestrated SG deployment, rotation of the SG can occur during the unsheathing process. This leads to misalignment of the vessels, and the fenestrations and is associated with poor clinical outcomes. The aim of this study was to develop a computational model of the FEVAR process to predict SG rotation. Six patient-specific cases are presented and compared with surgical case data. Realistic material properties, frictional effects, deployment methods, and boundary conditions are included in the model. A mean simulation error of 2 deg (range 1–4 deg) was observed. This model was then used to conduct a parameter study of frictional properties to see if rotation could be minimized. This study showed that increasing or decreasing the coefficients of friction (COF) between the sheath and the vessel walls would decrease the amount of rotation observed. Our model accurately predicts the amount of SG rotation observed during FEVAR and can be used as a preoperative planning tool within the surgical workflow.
Collapse
Affiliation(s)
- Ryan M. Sanford
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
| | - Sean A. Crawford
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| | - Helen Genis
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
| | - Matthew G. Doyle
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
| | - Thomas L. Forbes
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
| | - Cristina H. Amon
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| |
Collapse
|
18
|
Stefanov F, McGloughlin T, Morris L. A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms. Med Eng Phys 2016; 38:1458-1473. [PMID: 27773830 DOI: 10.1016/j.medengphy.2016.09.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Revised: 08/22/2016] [Accepted: 09/23/2016] [Indexed: 10/20/2022]
Abstract
There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and four pre-operative cases were computationally simulated, assessing the hemodynamic and geometrical effects for crossed (n= 4) and non-crossed (n= 4) configurations. SGs eliminated the occurrence of significant recirculations within the sac prior treatment. Dean's number predicted secondary flow locations with the greatest recirculations occurring at the outlets especially during the deceleration phase. Peak drag force varied from 3.9 to 8.7N, with greatest contribution occurring along the axial and anterior/posterior directions. Average resultant drag force was 20% smaller for the crossed configurations. Maximum drag force orientation varied from 1.4° to 51°. Drag force angle varied from 1° to 5° during one cardiac cycle. 44% to 62% of the resultant force acted along the proximal centerline where SG migration is most likely to occur. The clinician's decision for SG positioning may be a critical parameter, and should be considered prior to surgery. All crossed SG devices had an increased spiral flow effect along the distal legs with reductions in drag forces.
Collapse
Affiliation(s)
- Florian Stefanov
- Galway Medical Technologies Centre, Department of Mechanical and Industrial Engineering, Galway Mayo Institute of Technology, Galway, Ireland
| | - Tim McGloughlin
- Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Liam Morris
- Galway Medical Technologies Centre, Department of Mechanical and Industrial Engineering, Galway Mayo Institute of Technology, Galway, Ireland.
| |
Collapse
|
19
|
Ben Gur H, Kosa G, Brand M. Numerical analysis of the hemodynamics of an abdominal aortic aneurysm repaired using the endovascular chimney technique. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:977-80. [PMID: 26736427 DOI: 10.1109/embc.2015.7318527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This paper presents a numerical analysis of the hemodynamics in an abdominal aorta (AA) with an aneurysm repaired by a stent graft (SG) system using the chimney technique. Computational fluid dynamics (CFD) simulations were conducted in a model of an AA repaired with a chimney stent graft (CSG) inserted into a renal artery parallel to an aortic SG and a model of a healthy AA. Comparing the simulation results of these two cases suggests that the presence of the CSG in the AA causes changes in average wall shear stress (WSS), potentially damaging recirculation zones, and additional changes in flow patterns.
Collapse
|
20
|
Georgakarakos E, Gasser TC, Xenos M, Kontopodis N, Georgiadis GS, Ioannou CV. Applying findings of computational studies in vascular clinical practice: fact, fiction, or misunderstanding? J Endovasc Ther 2015; 21:434-8. [PMID: 24915594 DOI: 10.1583/14-4718e.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Efstratios Georgakarakos
- 1 Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Greece
| | | | | | | | | | | |
Collapse
|
21
|
Georgakarakos E, Argyriou C, Schoretsanitis N, Ioannou CV, Kontopodis N, Morgan R, Tsetis D. Geometrical Factors Influencing the Hemodynamic Behavior of the AAA Stent Grafts: Essentials for the Clinician. Cardiovasc Intervent Radiol 2014; 37:1420-9. [DOI: 10.1007/s00270-014-0927-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Accepted: 04/27/2014] [Indexed: 11/29/2022]
|
22
|
Georgakarakos E, Trellopoulos G, Ioannou CV, Tsetis D. Technical Challenges Encountered During Deployment of the Ovation Abdominal Aortic Stent-Graft System. J Endovasc Ther 2014; 21:333-8. [DOI: 10.1583/13-4515mr.1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
23
|
Georgiadis GS, Georgakarakos EI, Antoniou GA, Trellopoulos G, Argyriou C, Nikolopoulos ES, Charalampidis D, Schoretsanitis NG, Lazarides MK. Clinical Outcomes After Crossed-Limb vs. Conventional Endograft Configuration in Endovascular AAA Repair. J Endovasc Ther 2013; 20:853-62. [DOI: 10.1583/13-4286mr.1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|