1
|
Barahona J, Sahli Costabal F, Hurtado DE. Machine learning modeling of lung mechanics: Assessing the variability and propagation of uncertainty in respiratory-system compliance and airway resistance. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 243:107888. [PMID: 37948910 DOI: 10.1016/j.cmpb.2023.107888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 10/12/2023] [Accepted: 10/25/2023] [Indexed: 11/12/2023]
Abstract
BACKGROUND AND OBJECTIVE Traditional assessment of patient response in mechanical ventilation relies on respiratory-system compliance and airway resistance. Clinical evidence has shown high variability in these parameters, highlighting the difficulty of predicting them before the start of ventilation therapy. This motivates the creation of computational models that can connect structural and tissue features with lung mechanics. In this work, we leverage machine learning (ML) techniques to construct predictive lung function models informed by non-linear finite element simulations, and use them to investigate the propagation of uncertainty in the lung mechanical response. METHODS We revisit a continuum poromechanical formulation of the lungs suitable for determining patient response. Based on this framework, we create high-fidelity finite element models of human lungs from medical images. We also develop a low-fidelity model based on an idealized sphere geometry. We then use these models to train and validate three ML architectures: single-fidelity and multi-fidelity Gaussian process regression, and artificial neural networks. We use the best predictive ML model to further study the sensitivity of lung response to variations in tissue structural parameters and boundary conditions via sensitivity analysis and forward uncertainty quantification. Codes are available for download at https://github.com/comp-medicine-uc/ML-lung-mechanics-UQ RESULTS: The low-fidelity model delivers a lung response very close to that predicted by high-fidelity simulations and at a fraction of the computational time. Regarding the trained ML models, the multi-fidelity GP model consistently delivers better accuracy than the single-fidelity GP and neural network models in estimating respiratory-system compliance and resistance (R2∼0.99). In terms of computational efficiency, our ML model delivers a massive speed-up of ∼970,000× with respect to high-fidelity simulations. Regarding lung function, we observed an almost matched and non-linear behavior between specific structural parameters and chest wall stiffness with compliance. Also, we observed a strong modulation of airways resistance with tissue permeability. CONCLUSIONS Our findings unveil the relevance of specific lung tissue parameters and boundary conditions in the respiratory-system response. Furthermore, we highlight the advantages of adopting a multi-fidelity ML approach that combines data from different levels to yield accurate and efficient estimates of clinical mechanical markers. We envision that the methods presented here can open the way to the development of predictive ML models of the lung response that can inform clinical decisions.
Collapse
Affiliation(s)
- José Barahona
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, 7820436, Chile; Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, 7820436, Chile
| | - Francisco Sahli Costabal
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, 7820436, Chile; Department of Mechanical and Metallurgical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, 7820436, Chile
| | - Daniel E Hurtado
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, 7820436, Chile; Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, 7820436, Chile; Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02140, USA.
| |
Collapse
|
2
|
Genet M, Diaz J, Chapelle D, Moireau P. Reduced left ventricular dynamics modeling based on a cylindrical assumption. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3711. [PMID: 37203282 DOI: 10.1002/cnm.3711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 02/11/2023] [Accepted: 04/02/2023] [Indexed: 05/20/2023]
Abstract
Biomechanical modeling and simulation is expected to play a significant role in the development of the next generation tools in many fields of medicine. However, full-order finite element models of complex organs such as the heart can be computationally very expensive, thus limiting their practical usability. Therefore, reduced models are much valuable to be used, for example, for pre-calibration of full-order models, fast predictions, real-time applications, and so forth. In this work, focused on the left ventricle, we develop a reduced model by defining reduced geometry & kinematics while keeping general motion and behavior laws, allowing to derive a reduced model where all variables & parameters have a strong physical meaning. More specifically, we propose a reduced ventricular model based on cylindrical geometry & kinematics, which allows to describe the myofiber orientation through the ventricular wall and to represent contraction patterns such as ventricular twist, two important features of ventricular mechanics. Our model is based on the original cylindrical model of Guccione, McCulloch, & Waldman (1991); Guccione, Waldman, & McCulloch (1993), albeit with multiple differences: we propose a fully dynamical formulation, integrated into an open-loop lumped circulation model, and based on a material behavior that incorporates a fine description of contraction mechanisms; moreover, the issue of the cylinder closure has been completely reformulated; our numerical approach is novel aswell, with consistent spatial (finite element) and time discretizations. Finally, we analyze the sensitivity of the model response to various numerical and physical parameters, and study its physiological response.
Collapse
Affiliation(s)
- Martin Genet
- LMS, École Polytechnique/CNRS/Institut Polytechnique de Paris, Palaiseau, France
- Inria, MΞDISIM Team, Inria Saclay-Ile de France, Palaiseau, France
| | - Jérôme Diaz
- LMS, École Polytechnique/CNRS/Institut Polytechnique de Paris, Palaiseau, France
- Inria, MΞDISIM Team, Inria Saclay-Ile de France, Palaiseau, France
| | - Dominique Chapelle
- LMS, École Polytechnique/CNRS/Institut Polytechnique de Paris, Palaiseau, France
- Inria, MΞDISIM Team, Inria Saclay-Ile de France, Palaiseau, France
| | - Philippe Moireau
- LMS, École Polytechnique/CNRS/Institut Polytechnique de Paris, Palaiseau, France
- Inria, MΞDISIM Team, Inria Saclay-Ile de France, Palaiseau, France
| |
Collapse
|
3
|
Laville C, Fetita C, Gille T, Brillet PY, Nunes H, Bernaudin JF, Genet M. Comparison of optimization parametrizations for regional lung compliance estimation using personalized pulmonary poromechanical modeling. Biomech Model Mechanobiol 2023; 22:1541-1554. [PMID: 36913005 PMCID: PMC10009868 DOI: 10.1007/s10237-023-01691-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 01/09/2023] [Indexed: 03/14/2023]
Abstract
Interstitial lung diseases, such as idiopathic pulmonary fibrosis (IPF) or post-COVID-19 pulmonary fibrosis, are progressive and severe diseases characterized by an irreversible scarring of interstitial tissues that affects lung function. Despite many efforts, these diseases remain poorly understood and poorly treated. In this paper, we propose an automated method for the estimation of personalized regional lung compliances based on a poromechanical model of the lung. The model is personalized by integrating routine clinical imaging data - namely computed tomography images taken at two breathing levels in order to reproduce the breathing kinematic-notably through an inverse problem with fully personalized boundary conditions that is solved to estimate patient-specific regional lung compliances. A new parametrization of the inverse problem is introduced in this paper, based on the combined estimation of a personalized breathing pressure in addition to material parameters, improving the robustness and consistency of estimation results. The method is applied to three IPF patients and one post-COVID-19 patient. This personalized model could help better understand the role of mechanics in pulmonary remodeling due to fibrosis; moreover, patient-specific regional lung compliances could be used as an objective and quantitative biomarker for improved diagnosis and treatment follow up for various interstitial lung diseases.
Collapse
Affiliation(s)
- Colin Laville
- Laboratoire de Mécanique des Solides, École Polytechnique/CNRS/IPP, Palaiseau, France
- Inria, Palaiseau, France
| | | | - Thomas Gille
- Hypoxie et Poumon, Université Sorbonne Paris Nord/INSERM, Bobigny, France
- Hôpital Avicenne, APHP, Bobigny, France
| | - Pierre-Yves Brillet
- Hypoxie et Poumon, Université Sorbonne Paris Nord/INSERM, Bobigny, France
- Hôpital Avicenne, APHP, Bobigny, France
| | - Hilario Nunes
- Hypoxie et Poumon, Université Sorbonne Paris Nord/INSERM, Bobigny, France
- Hôpital Avicenne, APHP, Bobigny, France
| | | | - Martin Genet
- Laboratoire de Mécanique des Solides, École Polytechnique/CNRS/IPP, Palaiseau, France
- Inria, Palaiseau, France
| |
Collapse
|
4
|
Avilés-Rojas N, Hurtado DE. Whole-lung finite-element models for mechanical ventilation and respiratory research applications. Front Physiol 2022; 13:984286. [PMID: 36267590 PMCID: PMC9577367 DOI: 10.3389/fphys.2022.984286] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 09/12/2022] [Indexed: 11/30/2022] Open
Abstract
Mechanical ventilation has been a vital treatment for Covid-19 patients with respiratory failure. Lungs assisted with mechanical ventilators present a wide variability in their response that strongly depends on air-tissue interactions, which motivates the creation of simulation tools to enhance the design of ventilatory protocols. In this work, we aim to create anatomical computational models of the lungs that predict clinically-relevant respiratory variables. To this end, we formulate a continuum poromechanical framework that seamlessly accounts for the air-tissue interaction in the lung parenchyma. Based on this formulation, we construct anatomical finite-element models of the human lungs from computed-tomography images. We simulate the 3D response of lungs connected to mechanical ventilation, from which we recover physiological parameters of high clinical relevance. In particular, we provide a framework to estimate respiratory-system compliance and resistance from continuum lung dynamic simulations. We further study our computational framework in the simulation of the supersyringe method to construct pressure-volume curves. In addition, we run these simulations using several state-of-the-art lung tissue models to understand how the choice of constitutive models impacts the whole-organ mechanical response. We show that the proposed lung model predicts physiological variables, such as airway pressure, flow and volume, that capture many distinctive features observed in mechanical ventilation and the supersyringe method. We further conclude that some constitutive lung tissue models may not adequately capture the physiological behavior of lungs, as measured in terms of lung respiratory-system compliance. Our findings constitute a proof of concept that finite-element poromechanical models of the lungs can be predictive of clinically-relevant variables in respiratory medicine.
Collapse
Affiliation(s)
- Nibaldo Avilés-Rojas
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Daniel E. Hurtado
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
- *Correspondence: Daniel E. Hurtado,
| |
Collapse
|