1
|
Dubern JF, Hook AL, Carabelli AM, Chang CY, Lewis-Lloyd CA, Luckett JC, Burroughs L, Dundas AA, Humes DJ, Irvine DJ, Alexander MR, Williams P. Discovery of a polymer resistant to bacterial biofilm, swarming, and encrustation. SCIENCE ADVANCES 2023; 9:eadd7474. [PMID: 36696507 PMCID: PMC9876547 DOI: 10.1126/sciadv.add7474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
Innovative approaches to prevent catheter-associated urinary tract infections (CAUTIs) are urgently required. Here, we describe the discovery of an acrylate copolymer capable of resisting single- and multispecies bacterial biofilm formation, swarming, encrustation, and host protein deposition, which are major challenges associated with preventing CAUTIs. After screening ~400 acrylate polymers, poly(tert-butyl cyclohexyl acrylate) was selected for its biofilm- and encrustation-resistant properties. When combined with the swarming inhibitory poly(2-hydroxy-3-phenoxypropyl acrylate), the copolymer retained the bioinstructive properties of the respective homopolymers when challenged with Proteus mirabilis, Pseudomonas aeruginosa, Staphylococcus aureus, and Escherichia coli. Urinary tract catheterization causes the release of host proteins that are exploited by pathogens to colonize catheters. After preconditioning the copolymer with urine collected from patients before and after catheterization, reduced host fibrinogen deposition was observed, and resistance to diverse uropathogens was maintained. These data highlight the potential of the copolymer as a urinary catheter coating for preventing CAUTIs.
Collapse
Affiliation(s)
- Jean-Frédéric Dubern
- National Biofilms Innovation Centre, University of Nottingham Biodiscovery Institute, School of Life Sciences, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Andrew L. Hook
- Advanced Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Alessandro M. Carabelli
- National Biofilms Innovation Centre, University of Nottingham Biodiscovery Institute, School of Life Sciences, University of Nottingham, University Park, Nottingham NG7 2RD, UK
- Advanced Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Chien-Yi Chang
- National Biofilms Innovation Centre, University of Nottingham Biodiscovery Institute, School of Life Sciences, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Christopher A. Lewis-Lloyd
- Division of Gastrointestinal Surgery, Nottingham Digestive Diseases Centre NIHR Biomedical Research Unit, University of Nottingham and Nottingham University Hospitals NHS Trust, School of Medicine, Queen’s Medical Centre, Nottingham NG7 2UH, UK
| | - Jeni C. Luckett
- National Biofilms Innovation Centre, University of Nottingham Biodiscovery Institute, School of Life Sciences, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Laurence Burroughs
- Advanced Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Adam A. Dundas
- Centre for Additive Manufacturing, Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - David J. Humes
- Division of Gastrointestinal Surgery, Nottingham Digestive Diseases Centre NIHR Biomedical Research Unit, University of Nottingham and Nottingham University Hospitals NHS Trust, School of Medicine, Queen’s Medical Centre, Nottingham NG7 2UH, UK
| | - Derek J. Irvine
- Centre for Additive Manufacturing, Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Morgan R. Alexander
- Advanced Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Paul Williams
- National Biofilms Innovation Centre, University of Nottingham Biodiscovery Institute, School of Life Sciences, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| |
Collapse
|
2
|
Buddin MMHS, Ahmad AL, Zainuddin MIF. Prediction of CO 2 Permeance across ZIF-L@PDMS/PES Composite Membrane. MEMBRANES 2023; 13:134. [PMID: 36837637 PMCID: PMC9966868 DOI: 10.3390/membranes13020134] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 01/05/2023] [Accepted: 01/10/2023] [Indexed: 06/18/2023]
Abstract
The current work predicted the permeance of CO2 across a ZIF-L@PDMS/PES composite membrane using two different models. The membrane was fabricated by dipping a PES hollow fiber membrane in a coating solution made using PDMS that contained ZIF-L. First, flat sheet ZIF-L@PDMS membranes were fabricated to verify the role of ZIF-L on the gas separation performance of the membrane. Based on the data, the presence of ZIF-L in the PDMS matrix allowed enhancement of both permeability and selectivity of CO2, where the maximum value was obtained at 1 wt% of ZIF-L. The performance of ZIF-L@PDMS layer, as a function of ZIF-L loading, was well-predicted by the Cussler model. Such information was then used to model the CO2 permeance across ZIF-L@PDMS/PES composite membrane via the correction factor, which was introduced in the resistance in series model. This work discovered that the model must consider the penetration depth and the inorganic loading (in the case of ZIF-L@PDMS/PES). The error between the predicted CO2 permeance and the experimental results was found to be minimal.
Collapse
Affiliation(s)
- Meor Muhammad Hafiz Shah Buddin
- School of Chemical Engineering, Universiti Sains Malaysia Engineering Campus, Nibong Tebal 14300, Malaysia
- School of Chemical Engineering, College of Engineering, Universiti Teknologi MARA, Shah Alam 40450, Malaysia
| | - Abdul Latif Ahmad
- School of Chemical Engineering, Universiti Sains Malaysia Engineering Campus, Nibong Tebal 14300, Malaysia
| | | |
Collapse
|
3
|
Gomes M, Gomes LC, Teixeira-Santos R, Pereira MF, Soares OS, Mergulhão FJ. Carbon nanotube-based surfaces: Effect on the inhibition of single- and dual-species biofilms of Escherichia coli and Enterococcus faecalis. RESULTS IN SURFACES AND INTERFACES 2022. [DOI: 10.1016/j.rsurfi.2022.100090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
4
|
Teixeira-Santos R, Gomes LC, Mergulhão FJ. Recent advances in antimicrobial surfaces for urinary catheters. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2022. [DOI: 10.1016/j.cobme.2022.100394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
5
|
Domingues B, Pacheco M, Cruz JE, Carmagnola I, Teixeira‐Santos R, Laurenti M, Can F, Bohinc K, Moutinho F, Silva JM, Aroso IM, Lima E, Reis RL, Ciardelli G, Cauda V, Mergulhão FJ, Gálvez FS, Barros AA. Future Directions for Ureteral Stent Technology: From Bench to the Market. ADVANCED THERAPEUTICS 2021. [DOI: 10.1002/adtp.202100158] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Beatriz Domingues
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Margarida Pacheco
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Julia E. Cruz
- Endourology‐Endoscopy Department Minimally Invasive Surgery Centre Jesús Usón Cáceres 10071 Spain
| | - Irene Carmagnola
- Department of Mechanical and Aerospace Engineering Politecnico di Torino Turin 10129 Italy
- Polito BIOMedLAB Politecnico di Torino Turin 10129 Italy
| | - Rita Teixeira‐Santos
- LEPABE–Laboratory for Process Engineering Environment Biotechnology and Energy Faculty of Engineering University of Porto Porto 4200‐465 Portugal
| | - Marco Laurenti
- Department of Applied Science and Technology Politecnico di Torino Turin 10129 Italy
| | - Fusun Can
- Department of Medical Microbiology School of Medicine Koc University Istanbul 34450 Turkey
| | - Klemen Bohinc
- Faculty of Health Sciences University of Ljubljana Ljubljana 1000 Slovenia
| | - Fabíola Moutinho
- i3S‐Instituto de Investigação e Inovação em Saúde Universidade do Porto Porto 4200‐135 Portugal
- INEB‐Instituto de Engenharia Biomédica Universidade do Porto Porto 4200‐135 Portugal
| | - Joana M. Silva
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Ivo M. Aroso
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Estêvão Lima
- School of Health Sciences Life and Health Sciences Research Institute (ICVS) University of Minho Braga 4710‐057 Portugal
| | - Rui L. Reis
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering Politecnico di Torino Turin 10129 Italy
- Polito BIOMedLAB Politecnico di Torino Turin 10129 Italy
| | - Valentina Cauda
- Department of Applied Science and Technology Politecnico di Torino Turin 10129 Italy
| | - Filipe J. Mergulhão
- LEPABE–Laboratory for Process Engineering Environment Biotechnology and Energy Faculty of Engineering University of Porto Porto 4200‐465 Portugal
| | - Federico S. Gálvez
- Endourology‐Endoscopy Department Minimally Invasive Surgery Centre Jesús Usón Cáceres 10071 Spain
| | - Alexandre A. Barros
- 3B's Research Group‐Research Institute on Biomaterials Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine Avepark‐Parque Barco Guimarães 4805‐017 Portugal
- ICVS/3B's‐PT Government Associate Laboratory Braga/Guimarães 4805‐017 Portugal
| |
Collapse
|
6
|
Dundas AA, Kern S, Cuzzucoli Crucitti V, Scurr DJ, Wildman R, Irvine DJ, Alexander MR. A new particle mounting method for surface analysis. SURF INTERFACE ANAL 2021. [DOI: 10.1002/sia.7010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Adam A. Dundas
- Centre for Additive Manufacturing, Department of Chemical and Environmental Engineering, Faculty of Engineering University of Nottingham Nottingham UK
- Advanced Materials and Healthcare Technologies, School of Pharmacy University of Nottingham Nottingham UK
| | - Stefanie Kern
- Advanced Materials and Healthcare Technologies, School of Pharmacy University of Nottingham Nottingham UK
| | - Valentina Cuzzucoli Crucitti
- Centre for Additive Manufacturing, Department of Chemical and Environmental Engineering, Faculty of Engineering University of Nottingham Nottingham UK
| | - David J. Scurr
- Advanced Materials and Healthcare Technologies, School of Pharmacy University of Nottingham Nottingham UK
| | - Ricky Wildman
- Centre for Additive Manufacturing, Department of Chemical and Environmental Engineering, Faculty of Engineering University of Nottingham Nottingham UK
| | - Derek J. Irvine
- Centre for Additive Manufacturing, Department of Chemical and Environmental Engineering, Faculty of Engineering University of Nottingham Nottingham UK
| | - Morgan R. Alexander
- Advanced Materials and Healthcare Technologies, School of Pharmacy University of Nottingham Nottingham UK
| |
Collapse
|
7
|
Farnesene and norbornenyl methacrylate block copolymers: Application of thiol-ene clicking to improve thermal and mechanical properties. POLYMER 2021. [DOI: 10.1016/j.polymer.2021.124106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
8
|
Tarabal VS, Silva FG, Sinisterra RD, Gonçalves D, Silva J, Granjeiro JM, Speziali M, Granjeiro PA. Impact of DMPEI on Biofilm Adhesion on Latex Urinary Catheter. Recent Pat Biotechnol 2021; 15:51-66. [PMID: 33588743 DOI: 10.2174/1872208315666210215084127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 11/25/2020] [Accepted: 12/31/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND Microorganisms can migrate from the external environment to the patient's organism through the insertion of catheters. Despite being indispensable medical device, the catheter surface can be colonized by microorganisms and become a starting point for biofilm formation. Therefore, new technologies are being developed in order to modify surfaces to prevent the adhesion and survival of microorganisms. Patents with the use of DMPEI have been filed. OBJECTIVE In the present work, we coated latex catheter surfaces with 2 mg mL-1 DMPEI in different solvents, evaluated the wettability of the surface and the anti- biofilm activity of the coated catheter against Escherichia coli, Staphylococcus aureus, and Candida albicans. METHODS We coated the inner and outer catheter surfaces with 2 mg mL-1 of DMPEI solubilized in butanol, dimethylformamide, and cyclohexanone and the surfaces were analyzed visually. Contact angle measurement allowed the analysis of the wettability of the surfaces. The CFU mL-1 count evaluated E. coli, S. aureus, and C. albicans adhesion onto the control and treated surfaces. RESULTS The contact angle decreased from 50.48º to 46.93º on the inner surface and from 55.83º to 50.91º on the outer surface of latex catheters coated with DMPEI. The catheter coated with DMPEI showed anti-biofilm activity of 83%, 88%, and 93% on the inner surface and 100%, 92%, and 86% on the outer surface for E. coli, S. aureus, and C. albicans, respectively. CONCLUSION Latex catheter coated with DMPEI efficiently impaired the biofilm formation both on the outer and inner surfaces, showing a potential antimicrobial activity along with a high anti-biofilm activity for medical devices.
Collapse
Affiliation(s)
- Vinícius S Tarabal
- Campus Centro-Oeste, Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil
| | - Flávia G Silva
- Chemistry Department, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Ruben D Sinisterra
- Chemistry Department, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Daniel Gonçalves
- Campus Centro-Oeste, Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil
| | - Jose Silva
- Campus Centro-Oeste, Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil
| | - Jose M Granjeiro
- National Institute of Metrology, Quality and Technology, Duque de Caxias, Rio de Janeiro, Brazil
| | - Marcelo Speziali
- Chemistry Department, Federal University of Ouro Preto, Minas Gerais, Brazil
| | - Paulo A Granjeiro
- Campus Centro-Oeste, Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil
| |
Collapse
|
9
|
Carabelli A, Isgró M, Sanni O, Figueredo GP, Winkler DA, Burroughs L, Blok AJ, Dubern JF, Pappalardo F, Hook AL, Williams P, Alexander MR. Single-Cell Tracking on Polymer Microarrays Reveals the Impact of Surface Chemistry on Pseudomonas aeruginosa Twitching Speed and Biofilm Development. ACS APPLIED BIO MATERIALS 2020; 3:8471-8480. [PMID: 34308271 PMCID: PMC8291582 DOI: 10.1021/acsabm.0c00849] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 10/22/2020] [Indexed: 12/02/2022]
Abstract
Bacterial biofilms exhibit up to 1000 times greater resistance to antibiotic or host immune clearance than planktonic cells. Pseudomonas aeruginosa produces retractable type IV pili (T4P) that facilitate twitching motility on surfaces. The deployment of pili is one of the first responses of bacteria to surface interactions and because of their ability to contribute to cell surface adhesion and biofilm formation, this has relevance to medical device-associated infections. While polymer chemistry is known to influence biofilm development, its impact on twitching motility is not understood. Here, we combine a polymer microarray format with time-lapse automated microscopy to simultaneously assess P. aeruginosa twitching motility on 30 different methacrylate/acrylate polymers over 60 min post inoculation using a high-throughput system. During this critical initial period where the decision to form a biofilm is thought to occur, similar numbers of bacterial cells accumulate on each polymer. Twitching motility is observed on all polymers irrespective of their chemistry and physical surface properties, in contrast to the differential biofilm formation noted after 24 h of incubation. However, on the microarray polymers, P. aeruginosa cells twitch at significantly different speeds, ranging from 5 to ∼13 nm/s, associated with crawling or walking and are distinguishable from the different cell surface tilt angles observed. Chemometric analysis using partial least-squares (PLS) regression identifies correlations between surface chemistry, as measured by time-of-flight secondary ion mass spectrometry (ToF-SIMS), and both biofilm formation and single-cell twitching speed. The relationships between surface chemistry and these two responses are different for each process. There is no correlation between polymer surface stiffness and roughness as determined by atomic force measurement (AFM), or water contact angle (WCA), and twitching speed or biofilm formation. This reinforces the dominant and distinct contributions of material surface chemistry to twitching speed and biofilm formation.
Collapse
Affiliation(s)
- Alessandro
M. Carabelli
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
| | - Marco Isgró
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
| | - Olutoba Sanni
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
| | | | - David A. Winkler
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
- Monash
Institute of Pharmaceutical Sciences, Monash
University, Parkville 3052, Australia
- La Trobe
Institute for Molecular Science, la Trobe
University, Bundoora 3083, Australia
- CSIRO
Data61, Pullenvale 4069, Australia
| | - Laurence Burroughs
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
| | - Andrew J. Blok
- Division
of Molecular Therapeutics and Formulation, School of Pharmacy, University of Nottingham, Nottingham, NG7 2RD, U.K.
| | - Jean-Frédéric Dubern
- Biodiscovery
Institute and School of Life Sciences, University
of Nottingham, Nottingham NG7 2RD, U.K.
| | - Francesco Pappalardo
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
| | - Andrew L. Hook
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
| | - Paul Williams
- Biodiscovery
Institute and School of Life Sciences, University
of Nottingham, Nottingham NG7 2RD, U.K.
| | - Morgan R. Alexander
- Advanced
Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, U.K.
| |
Collapse
|
10
|
Zinc-loaded palygorskite nanocomposites for catheter coating with excellent antibacterial and anti-biofilm properties. Colloids Surf A Physicochem Eng Asp 2020. [DOI: 10.1016/j.colsurfa.2020.124965] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
11
|
Singh T, Hook AL, Luckett J, Maitz MF, Sperling C, Werner C, Davies MC, Irvine DJ, Williams P, Alexander MR. Discovery of hemocompatible bacterial biofilm-resistant copolymers. Biomaterials 2020; 260:120312. [PMID: 32866726 PMCID: PMC7534038 DOI: 10.1016/j.biomaterials.2020.120312] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 07/31/2020] [Accepted: 08/07/2020] [Indexed: 12/24/2022]
Abstract
Blood-contacting medical devices play an important role within healthcare and are required to be biocompatible, hemocompatible and resistant to microbial colonization. Here we describe a high throughput screen for copolymers with these specific properties. A series of weakly amphiphilic monomers are combinatorially polymerized with acrylate glycol monomers of varying chain lengths to create a library of 645 multi-functional candidate materials containing multiple chemical moieties that impart anti-biofilm, hemo- and immuno-compatible properties. These materials are screened in over 15,000 individual biological assays, targeting two bacterial species, one Gram negative (Pseudomonas aeruginosa) and one Gram positive (Staphylococcus aureus) commonly associated with central venous catheter infections, using 5 different measures of hemocompatibility and 6 measures of immunocompatibililty. Selected copolymers reduce platelet activation, platelet loss and leukocyte activation compared with the standard comparator PTFE as well as reducing bacterial biofilm formation in vitro by more than 82% compared with silicone. Poly(isobornyl acrylate-co-triethylene glycol methacrylate) (75:25) is identified as the optimal material across all these measures reducing P. aeruginosa biofilm formation by up to 86% in vivo in a murine foreign body infection model compared with uncoated silicone.
Collapse
Affiliation(s)
- Taranjit Singh
- School of Pharmacy, University of Nottingham, Nottingham, NG7 2RD, UK; Biodiscovery Institute and School of Life Sciences, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Andrew L Hook
- School of Pharmacy, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Jeni Luckett
- Biodiscovery Institute and School of Life Sciences, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Manfred F Maitz
- Leibniz Institute of Polymer Research Dresden, Max Bergmann Centre for Biomaterials Dresden, Hohe Str. 6, D-01069, Dresden, Germany
| | - Claudia Sperling
- Leibniz Institute of Polymer Research Dresden, Max Bergmann Centre for Biomaterials Dresden, Hohe Str. 6, D-01069, Dresden, Germany
| | - Carsten Werner
- Leibniz Institute of Polymer Research Dresden, Max Bergmann Centre for Biomaterials Dresden, Hohe Str. 6, D-01069, Dresden, Germany
| | - Martyn C Davies
- School of Pharmacy, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Derek J Irvine
- Department of Chemical and Environmental Engineering, Faculty of Engineering, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Paul Williams
- Biodiscovery Institute and School of Life Sciences, University of Nottingham, Nottingham, NG7 2RD, UK
| | | |
Collapse
|
12
|
Vallieres C, Hook AL, He Y, Crucitti VC, Figueredo G, Davies CR, Burroughs L, Winkler DA, Wildman RD, Irvine DJ, Alexander MR, Avery SV. Discovery of (meth)acrylate polymers that resist colonization by fungi associated with pathogenesis and biodeterioration. SCIENCE ADVANCES 2020; 6:eaba6574. [PMID: 32548270 PMCID: PMC7274803 DOI: 10.1126/sciadv.aba6574] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 04/08/2020] [Indexed: 05/31/2023]
Abstract
Fungi have major, negative socioeconomic impacts, but control with bioactive agents is increasingly restricted, while resistance is growing. Here, we describe an alternative fungal control strategy via materials operating passively (i.e., no killing effect). We screened hundreds of (meth)acrylate polymers in high throughput, identifying several that reduce attachment of the human pathogen Candida albicans, the crop pathogen Botrytis cinerea, and other fungi. Specific polymer functional groups were associated with weak attachment. Low fungal colonization materials were not toxic, supporting their passive, anti-attachment utility. We developed a candidate monomer formulation for inkjet-based 3D printing. Printed voice prosthesis components showed up to 100% reduction in C. albicans biofilm versus commercial materials. Furthermore, spray-coated leaf surfaces resisted fungal infection, with no plant toxicity. This is the first high-throughput study of polymer chemistries resisting fungal attachment. These materials are ready for incorporation in products to counteract fungal deterioration of goods, food security, and health.
Collapse
Affiliation(s)
- Cindy Vallieres
- School of Life Sciences, University of Nottingham, Nottingham, UK
| | - Andrew L. Hook
- School of Pharmacy, University of Nottingham, Nottingham, UK
| | - Yinfeng He
- Faculty of Engineering, University of Nottingham, Nottingham, UK
| | | | | | | | | | - David A. Winkler
- School of Pharmacy, University of Nottingham, Nottingham, UK
- Monash Institute of Pharmaceutical Sciences, Monash University, Australia
- La Trobe Institute for Molecular Science, La Trobe University, Australia
- CSIRO Manufacturing, Clayton, Australia
| | - Ricky D. Wildman
- Faculty of Engineering, University of Nottingham, Nottingham, UK
| | - Derek J. Irvine
- Faculty of Engineering, University of Nottingham, Nottingham, UK
| | | | - Simon V. Avery
- School of Life Sciences, University of Nottingham, Nottingham, UK
| |
Collapse
|
13
|
Burroughs L, Ashraf W, Singh S, Martinez-Pomares L, Bayston R, Hook AL. Development of dual anti-biofilm and anti-bacterial medical devices. Biomater Sci 2020; 8:3926-3934. [DOI: 10.1039/d0bm00709a] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Silicone catheters impregnated with antibiotics and coated with an anti-attachment polyacrylate produce a device with dual anti-biofilm and anti-bacterial properties.
Collapse
Affiliation(s)
| | | | - Sonali Singh
- School of Life Sciences
- Faculty of Medicine and Health Sciences
- Queen's Medical Centre
- Nottingham NG7 2UH
- UK
| | - Luisa Martinez-Pomares
- School of Life Sciences
- Faculty of Medicine and Health Sciences
- Queen's Medical Centre
- Nottingham NG7 2UH
- UK
| | | | - Andrew L. Hook
- School of Pharmacy
- University of Nottingham
- Nottingham NG7 2RD
- UK
| |
Collapse
|
14
|
Srisang S, Wongsuwan N, Boongird A, Ungsurungsie M, Wanasawas P, Nasongkla N. Multilayer nanocoating of Foley urinary catheter by chlorhexidine-loaded nanoparticles for prolonged release and anti-infection of urinary tract. INT J POLYM MATER PO 2019. [DOI: 10.1080/00914037.2019.1655752] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Siriwan Srisang
- Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom, Thailand
- Department of Engineering, King Mongkut's Institute of Technology Ladkrabang, Prince of Chumphon Campus, Chumphon, Thailand
| | - Nattarat Wongsuwan
- Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom, Thailand
| | - Atthaporn Boongird
- Department of Surgery, Neurosurgical Unit, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Malyn Ungsurungsie
- S&J International Enterprises Public Company Limited, Tungwatdon, Sathon, Bangkok, Thailand
| | - Pimphaka Wanasawas
- S&J International Enterprises Public Company Limited, Tungwatdon, Sathon, Bangkok, Thailand
| | - Norased Nasongkla
- Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom, Thailand
| |
Collapse
|
15
|
Maupu A, Kanawati Y, Métafiot A, Maric M. Ethylene Glycol Dicyclopentenyl (Meth)Acrylate Homo and Block Copolymers via Nitroxide Mediated Polymerization. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E1547. [PMID: 31083510 PMCID: PMC6539251 DOI: 10.3390/ma12091547] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 05/05/2019] [Accepted: 05/08/2019] [Indexed: 06/09/2023]
Abstract
Nitroxide-mediated polymerization (NMP), (homo and block copolymerization with styrene (S) and butyl methacrylate/S) of ethylene glycol dicyclopentenyl ether (meth)acrylates (EGDEA and EGDEMA) was studied using BlocBuilder alkoxyamines. EGDEA homopolymerization was not well-controlled, independent of temperature (90-120 °C), or additional free nitroxide (0-10 mol%) used. Number average molecular weights (Mn) achieved for poly(EGDEA) were 4.0-9.5 kg mol-1 and were accompanied by high dispersity (Ð = Mw/Mn = 1.62-2.09). Re-initiation and chain extension of the poly(EGDEA) chains with styrene (S) indicated some block copolymer formation, but a high fraction of chains were terminated irreversibly. EGDEA-stat-S statistical copolymerizations with a low mol fraction S in initial feed, fS,0 = 0.05, were slightly better controlled compared to poly(EGDEA) homopolymerizations (Ð was reduced to 1.44 compared to 1.62 at similar conditions). EGDEMA, in contrast, was successfully polymerized using a small fraction of S (fS,0 ~ 10 mol%) to high conversion (72%) to form well-defined EGDEMA-rich random copolymer (molar composition = FEGDEMA = 0.87) of Mn = 14.3 kg mol-1 and Ð = 1.38. EGDEMA-rich compositions were also polymerized with the unimolecular succinimidyl ester form of BlocBuilder initiator, NHS-BlocBuilder with similar results, although Ðs were higher ~1.6. Chain extensions resulted in monomodal shifts to higher molecular weights, indicating good chain end fidelity.
Collapse
Affiliation(s)
- Alexandre Maupu
- Department of Chemical Engineering, Centre québécois sur les matériaux fonctionnels/Quebec Centre for Advanced Materials (CQMF/QCAM), Centre de recherche sur les systèmes polymères et composites à haute performance (CREPEC), McGill Institute of Advanced Materials (MIAM), McGill University, Montreal, QC H3A 0C5, Canada.
| | - Yara Kanawati
- Department of Chemical Engineering, Centre québécois sur les matériaux fonctionnels/Quebec Centre for Advanced Materials (CQMF/QCAM), Centre de recherche sur les systèmes polymères et composites à haute performance (CREPEC), McGill Institute of Advanced Materials (MIAM), McGill University, Montreal, QC H3A 0C5, Canada.
| | - Adrien Métafiot
- Department of Chemical Engineering, Centre québécois sur les matériaux fonctionnels/Quebec Centre for Advanced Materials (CQMF/QCAM), Centre de recherche sur les systèmes polymères et composites à haute performance (CREPEC), McGill Institute of Advanced Materials (MIAM), McGill University, Montreal, QC H3A 0C5, Canada.
| | - Milan Maric
- Department of Chemical Engineering, Centre québécois sur les matériaux fonctionnels/Quebec Centre for Advanced Materials (CQMF/QCAM), Centre de recherche sur les systèmes polymères et composites à haute performance (CREPEC), McGill Institute of Advanced Materials (MIAM), McGill University, Montreal, QC H3A 0C5, Canada.
| |
Collapse
|
16
|
Laube N, Bernsmann F, Fisang C. Individualisierte Patientenversorgung mit urologischen Implantaten durch biofilmabweisende Oberflächenkonzepte. Urologe A 2019; 58:143-150. [DOI: 10.1007/s00120-018-0623-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
17
|
Graham DJ, Gamble LJ. Dealing with image shifting in 3D ToF-SIMS depth profiles. Biointerphases 2018; 13:06E402. [PMID: 30185054 PMCID: PMC6125139 DOI: 10.1116/1.5041740] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 08/01/2018] [Accepted: 08/07/2018] [Indexed: 11/17/2022] Open
Abstract
The high sputter efficiency and low damage of gas cluster ion beams have enabled depth profiling to greater depths within organic samples using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Due to the typically fixed geometry of the ion sources used in ToF-SIMS, as one digs into a surface, the position sampled by ion beams shifts laterally. This causes a lateral shift in the resulting images that can become quite significant when profiling down more than one micron. Here, three methods to compensate for this image shifting are presented in order to more accurately stack the images to present a 3D representation. These methods include (1) using software to correct the image shifts post-acquisition, (2) correcting the sample height during acquisition, and (3) adjusting the beam position during acquisition. The advantages and disadvantages of these methods are discussed. It was found that all three methods were successful in compensating for image shifting in ToF-SIMS depth profiles resulting in a more accurate display of the 3D data. Features from spherical objects that were ellipsoidal prior to shifting were seen to be spherical after correction. Software shifting is convenient as it can be applied after data acquisition. However, when using software shifting, one must take into account the scan size and the size of the features of interest as image shifts can be significant and can result in cropping of features of interest. For depth profiles deeper than a few microns, hardware methods should be used as they preserve features of interest within the field of view regardless of the profile depth. Software shifting can also be used to correct for small shifts not accounted for by hardware methods. A combination of hardware and software shift correction can enable correction for a wide range of samples and profiling depths. The scripts required for the software shifting demonstrated herein are provided along with tutorials in the supplementary material.
Collapse
Affiliation(s)
- Daniel J Graham
- NESAC/BIO, Department of Bioengineering, University of Washington, Seattle, Washington 98195
| | - Lara J Gamble
- NESAC/BIO, Department of Bioengineering, University of Washington, Seattle, Washington 98195
| |
Collapse
|
18
|
Archaeal tetraether lipid coatings-A strategy for the development of membrane analog spacer systems for the site-specific functionalization of medical surfaces. Biointerphases 2018; 13:011004. [PMID: 29382205 DOI: 10.1116/1.5008816] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The primary goal of our investigation was the development of a versatile immobilization matrix based on archaeal tetraether lipids that meets the most important prerequisites to render an implant surface bioactive by binding specific functional groups or functional polymers with the necessary flexibility and an optimal spatial arrangement to be bioavailable. From this point of view, it appears obvious that numerous efforts made recently to avoid initial bacterial adhesion on catheter surfaces as an important prerequisite of material associated infection episodes have shown only a limited efficiency since the bioactive entities could not be presented in an optimal conformation and a stable density. A significant improvement of this situation can be achieved by highly specific biomimetic modifications of the catheter surfaces. The term "biomimetic" originates from the fact that specific archaeal tetraether lipids were introduced to form a membrane analog monomolecular spacer system, which (1) can be immobilized on nearly all solid surfaces and (2) chemically modified to present a tailor-made functionality in contact with aqueous media either to avoid or inhibit surface fouling or to equip any implant surface with the necessary chemical functionality to enable cell adhesion and tissue integration. Ultrathin films based on tetraether lipids isolated from archaea Thermoplasma acidophilum were used as a special biomimetic immobilization matrix on the surface of commercial medical silicon elastomers. A complete performance control of the membrane analog coatings was realized in addition to biofunctionality tests, including the proof of cytotoxicity and hemocompatibility according to DIN EN ISO 10993. In order to make sure that the developed immobilization matrix including the grafted functional groups are biocompatible under in vivo-conditions, specific animal tests were carried out to examine the in vivo-performance. It can be concluded that the tetraether lipid based coating systems on silicone have shown no signs of cytotoxicity and a good hemocompatibility. Moreover, no mutagenic effects, no irritation effects, and no sensitization effects could be demonstrated. After an implantation period of 28 days, no irregularities were found.
Collapse
|