1
|
Nguyen PT, Le TK, Nguyen HQ, Ho LB. Harnessing graph state resources for robust quantum magnetometry under noise. Sci Rep 2024; 14:20528. [PMID: 39227686 PMCID: PMC11371932 DOI: 10.1038/s41598-024-71365-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 08/26/2024] [Indexed: 09/05/2024] Open
Abstract
Precise measurement of magnetic fields is essential for various applications, such as fundamental physics, space exploration, and biophysics. Although recent progress in quantum engineering has assisted in creating advanced quantum magnetometers, there are still ongoing challenges in improving their efficiency and noise resistance. This study focuses on using symmetric graph state resources for quantum magnetometry to enhance measurement precision by analyzing the estimation theory under time-homogeneous and time-inhomogeneous noise models. The results show a significant improvement in estimating both single and multiple Larmor frequencies. In single Larmor frequency estimation, the quantum Fisher information spans a spectrum from the standard quantum limit to the Heisenberg limit within a periodic range of the Larmor frequency, and in the case of multiple Larmor frequencies, it can exceed the standard quantum limit for both noisy cases. This study highlights the potential of graph state-based methods for improving magnetic field measurements under noisy environments.
Collapse
Affiliation(s)
- Phu Trong Nguyen
- Department of Advanced Material Science and Nanotechnology, University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, Hanoi, 11307, Vietnam
| | - Trung Kien Le
- Department of Physics, University of California, Santa Barbara, Santa Barbara, USA
- Department of Applied Physics, Stanford University, Stanford, USA
| | - Hung Q Nguyen
- Nano and Energy Center, University of Science, Vietnam National University, Hanoi, 120401, Vietnam
| | - Le Bin Ho
- Frontier Research Institute for Interdisciplinary Sciences, Tohoku University, Sendai, 980-8578, Japan.
- Department of Applied Physics, Graduate School of Engineering, Tohoku University, Sendai, 980-8579, Japan.
| |
Collapse
|
2
|
Bondza SA, Leopold T, Schwarz R, Lisdat C. Achromatic, planar Fresnel-reflector for a single-beam magneto-optical trap. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:013202. [PMID: 38270499 DOI: 10.1063/5.0174674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 12/19/2023] [Indexed: 01/26/2024]
Abstract
We present a novel achromatic, planar, periodic mirror structure for single-beam magneto-optical trapping and demonstrate its use in the first- and second-stage cooling and trapping for different isotopes of strontium. We refer to it as a Fresnel magneto-optical trap (MOT) as the structure is inspired by Fresnel lenses. By design, it avoids many of the problems that arise for multi-color cooling using planar structures based on diffraction gratings, which have been the dominant planar structures to be used for single-beam trapping thus far. In addition to a complex design process and cost-intensive fabrication, diffraction gratings suffer from their inherent chromaticity, which causes different axial displacements of trap volumes for different wavelengths and necessitates trade-offs in their diffraction properties and achievable trap depths. In contrast, the Fresnel-reflector structure presented here is a versatile, easy-to-manufacture device that combines achromatic beam steering with the advantages of a planar architecture. It enables miniaturizing trapping systems for alkaline-earth-like atoms with multiple cooling transitions as well as multi-species trapping in the ideal tetrahedral configuration and within the same volume above the structure. Our design presents a novel approach for the miniaturization of cold-atom systems based on single-beam MOTs and enables the widespread adoption of these systems.
Collapse
Affiliation(s)
- S A Bondza
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
- Deutsches Zentrum für Luft- und Raumfahrt e.V. (DLR), Institut für Satellitengeodäsie und Inertialsensorik, Callinstraße 30b, 30167 Hannover, Germany
| | - T Leopold
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
- Deutsches Zentrum für Luft- und Raumfahrt e.V. (DLR), Institut für Satellitengeodäsie und Inertialsensorik, Callinstraße 30b, 30167 Hannover, Germany
| | - R Schwarz
- Deutsches Zentrum für Luft- und Raumfahrt e.V. (DLR), Institut für Satellitengeodäsie und Inertialsensorik, Callinstraße 30b, 30167 Hannover, Germany
| | - C Lisdat
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| |
Collapse
|
3
|
Konopsky V. Photonic Crystal Surface Modes for Trapping and Waveguiding of Ultracold Atoms. SENSORS (BASEL, SWITZERLAND) 2023; 23:8812. [PMID: 37960512 PMCID: PMC10648538 DOI: 10.3390/s23218812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/26/2023] [Accepted: 10/28/2023] [Indexed: 11/15/2023]
Abstract
The design of a photonic system for the trapping and waveguiding of ultracold atoms far above a dielectric surface is proposed and analyzed. The system consists of an optical rib waveguide deposited on a planar one-dimensional photonic crystal, which sustains two wavelengths of photonic crystal surface modes tuned in the red and blue sides relative to the atomic transition of the neutral atom. The addition of a third blue-tuned wavelength to the system allows the neutral atoms to be stabilized in the lateral dimension above the rib waveguide. Trapping atoms at relatively large distances, more than 600 nm above the dielectric surface, allows to reduce the influence of Casimir-Polder forces in this system. The detailed design methodology and specifications of the photonic system are provided. The presented design can be employed in atomic chips and quantum sensors.
Collapse
Affiliation(s)
- Valery Konopsky
- Institute of Spectroscopy, Fizicheskaya, 5, Troitsk, Moscow 108840, Russia
| |
Collapse
|
4
|
Bai SY, An JH. Floquet Engineering to Overcome No-Go Theorem of Noisy Quantum Metrology. PHYSICAL REVIEW LETTERS 2023; 131:050801. [PMID: 37595225 DOI: 10.1103/physrevlett.131.050801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 07/17/2023] [Indexed: 08/20/2023]
Abstract
Permitting a more precise measurement to physical quantities than the classical limit by using quantum resources, quantum metrology holds a promise in developing many revolutionary technologies. However, the noise-induced decoherence forces its superiority to disappear, which is called no-go theorem of noisy quantum metrology and constrains its application. We propose a scheme to overcome the no-go theorem by Floquet engineering. It is found that, by applying a periodic driving on the atoms of the Ramsey spectroscopy, the ultimate sensitivity to measure their frequency characterized by quantum Fisher information returns to the ideal t^{2} scaling with the encoding time whenever a Floquet bound state is formed by the system consisting of each driven atom and its local noise. Combining with the optimal control, this mechanism also allows us to retrieve the ideal Heisenberg-limit scaling with the atom number N. Our result gives an efficient way to avoid the no-go theorem of noisy quantum metrology and to realize high-precision measurements.
Collapse
Affiliation(s)
- Si-Yuan Bai
- Key Laboratory of Quantum Theory and Applications of MoE, Lanzhou Center for Theoretical Physics, and Key Laboratory of Theoretical Physics of Gansu Province, Lanzhou University, Lanzhou 730000, China
| | - Jun-Hong An
- Key Laboratory of Quantum Theory and Applications of MoE, Lanzhou Center for Theoretical Physics, and Key Laboratory of Theoretical Physics of Gansu Province, Lanzhou University, Lanzhou 730000, China
| |
Collapse
|
5
|
Li D, He W, Shi S, Wu B, Xiao Y, Lin Q, Li L. Review of Atom Chips for Absolute Gravity Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23115089. [PMID: 37299815 DOI: 10.3390/s23115089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/07/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023]
Abstract
As a powerful tool in scientific research and industrial technologies, the cold atom absolute gravity sensor (CAGS) based on cold atom interferometry has been proven to be the most promising new generation high-precision absolute gravity sensor. However, large size, heavy weight, and high-power consumption are still the main restriction factors of CAGS being applied for practical applications on mobile platforms. Combined with cold atom chips, it is possible to drastically reduce the complexity, weight, and size of CAGS. In this review, we started from the basic theory of atom chips to chart a clear development path to related technologies. Several related technologies including micro-magnetic traps, micro magneto-optical traps, material selection, fabrication, and packaging methods have been discussed. This review gives an overview of the current developments in a variety of cold atom chips, and some actual CAGS systems based on atom chips are also discussed. We summarize by listing some of the challenges and possible directions for further development in this area.
Collapse
Affiliation(s)
- Dezhao Li
- Zhejiang Provincial Key Laboratory of Quantum Precision Measurement, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Wenfeng He
- Zhejiang Provincial Key Laboratory of Quantum Precision Measurement, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Shengnan Shi
- Zhejiang Provincial Key Laboratory of Quantum Precision Measurement, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Bin Wu
- Zhejiang Provincial Key Laboratory of Quantum Precision Measurement, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Yuhua Xiao
- Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China
| | - Qiang Lin
- Zhejiang Provincial Key Laboratory of Quantum Precision Measurement, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Long Li
- Department of Aeronautics and Astronautics, Fudan University, Shanghai 200433, China
| |
Collapse
|
6
|
McGilligan JP, Gallacher K, Griffin PF, Paul DJ, Arnold AS, Riis E. Micro-fabricated components for cold atom sensors. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:091101. [PMID: 36182455 DOI: 10.1063/5.0101628] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 08/02/2022] [Indexed: 06/16/2023]
Abstract
Laser cooled atoms have proven transformative for precision metrology, playing a pivotal role in state-of-the-art clocks and interferometers and having the potential to provide a step-change in our modern technological capabilities. To successfully explore their full potential, laser cooling platforms must be translated from the laboratory environment and into portable, compact quantum sensors for deployment in practical applications. This transition requires the amalgamation of a wide range of components and expertise if an unambiguously chip-scale cold atom sensor is to be realized. We present recent developments in cold-atom sensor miniaturization, focusing on key components that enable laser cooling on the chip-scale. The design, fabrication, and impact of the components on sensor scalability and performance will be discussed with an outlook to the next generation of chip-scale cold atom devices.
Collapse
Affiliation(s)
- J P McGilligan
- SUPA and Department of Physics, University of Strathclyde, Glasgow G4 0NG, United Kingdom
| | - K Gallacher
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8LT, United Kingdom
| | - P F Griffin
- SUPA and Department of Physics, University of Strathclyde, Glasgow G4 0NG, United Kingdom
| | - D J Paul
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8LT, United Kingdom
| | - A S Arnold
- SUPA and Department of Physics, University of Strathclyde, Glasgow G4 0NG, United Kingdom
| | - E Riis
- SUPA and Department of Physics, University of Strathclyde, Glasgow G4 0NG, United Kingdom
| |
Collapse
|
7
|
Gautier R, Guessoum M, Sidorenkov LA, Bouton Q, Landragin A, Geiger R. Accurate measurement of the Sagnac effect for matter waves. SCIENCE ADVANCES 2022; 8:eabn8009. [PMID: 35687688 PMCID: PMC9187224 DOI: 10.1126/sciadv.abn8009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 04/27/2022] [Indexed: 06/04/2023]
Abstract
A rotating interferometer with paths that enclose a physical area exhibits a phase shift proportional to this area and to the rotation rate of the frame. Understanding the origin of this so-called Sagnac effect has played a key role in the establishment of the theory of relativity and has pushed for the development of precision optical interferometers. The fundamental importance of the Sagnac effect motivated the realization of experiments to test its validity for waves beyond optical, but precision measurements remained a challenge. Here, we report the accurate test of the Sagnac effect for matter waves, by using a Cesium atom interferometer featuring a geometrical area of 11 cm2 and two sensitive axes of measurements. We measure the phase shift induced by Earth's rotation and find agreement with the theoretical prediction at an accuracy level of 25 parts per million. Beyond the importance for fundamental physics, our work opens practical applications in seismology and geodesy.
Collapse
|
8
|
Gehl M, Kindel W, Karl N, Orozco A, Musick K, Trotter D, Dallo C, Starbuck A, Leenheer A, DeRose C, Biedermann G, Jau YY, Lee J. Characterization of suspended membrane waveguides towards a photonic atom trap integrated platform. OPTICS EXPRESS 2021; 29:13129-13140. [PMID: 33985054 DOI: 10.1364/oe.418986] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 03/18/2021] [Indexed: 06/12/2023]
Abstract
We demonstrate an optical waveguide device, capable of supporting the high, in-vacuum, optical power necessary for trapping a single atom or a cold atom ensemble with evanescent fields. Our photonic integrated platform, with suspended membrane waveguides, successfully manages optical powers of 6 mW (500 μm span) to nearly 30 mW (125 μm span) over an un-tethered waveguide span. This platform is compatible with laser cooling and magneto-optical traps (MOTs) in the vicinity of the suspended waveguide, called the membrane MOT and the needle MOT, a key ingredient for efficient trap loading. We evaluate two novel designs that explore critical thermal management features that enable this large power handling. This work represents a significant step toward an integrated platform for coupling neutral atom quantum systems to photonic and electronic integrated circuits on silicon.
Collapse
|
9
|
Lee J, Biedermann G, Mudrick J, Douglas EA, Jau YY. Demonstration of a MOT in a sub-millimeter membrane hole. Sci Rep 2021; 11:8807. [PMID: 33888789 PMCID: PMC8062532 DOI: 10.1038/s41598-021-87927-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 03/31/2021] [Indexed: 11/23/2022] Open
Abstract
We demonstrate the generation of a cold-atom ensemble within a sub-millimeter diameter hole in a transparent membrane, a so-called “membrane MOT”. With a sub-Doppler cooling process, the atoms trapped by the membrane MOT are cooled down to 10 \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\upmu$$\end{document}μK. The atom number inside the unbridged/bridged membrane hole is about \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$10^4$$\end{document}104 to \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$10^5$$\end{document}105, and the \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$1/e^2$$\end{document}1/e2-diameter of the MOT cloud is about 180 \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\upmu$$\end{document}μm for a 400 \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\upmu$$\end{document}μm-diameter membrane hole. Such a membrane device can, in principle, efficiently load cold atoms into the evanescent-field optical trap generated by the suspended membrane waveguide for strong atom-light interaction and provide the capability of sufficient heat dissipation at the waveguide. This represents a key step toward the photonic atom trap integrated platform (ATIP).
Collapse
Affiliation(s)
- Jongmin Lee
- Sandia National Laboratories, Albuquerque, NM, 87185, USA.
| | | | - John Mudrick
- Sandia National Laboratories, Albuquerque, NM, 87185, USA
| | | | - Yuan-Yu Jau
- Sandia National Laboratories, Albuquerque, NM, 87185, USA
| |
Collapse
|
10
|
Semiclassical Phase Analysis for a Trapped-Atom Sagnac Interferometer. ATOMS 2021. [DOI: 10.3390/atoms9020021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
A Sagnac atom interferometer can be constructed using a Bose–Einstein condensate trapped in a cylindrically symmetric harmonic potential. Using the Bragg interaction with a set of laser beams, the atoms can be launched into circular orbits, with two counterpropagating interferometers allowing many sources of common-mode noise to be excluded. In a perfectly symmetric and harmonic potential, the interferometer output would depend only on the rotation rate of the apparatus. However, deviations from the ideal case can lead to spurious phase shifts. These phase shifts have been theoretically analyzed for anharmonic perturbations up to quartic in the confining potential, as well as angular deviations of the laser beams, timing deviations of the laser pulses, and motional excitations of the initial condensate. Analytical and numerical results show the leading effects of the perturbations to be second order. The scaling of the phase shifts with the number of orbits and the trap axial frequency ratio are determined. The results indicate that sensitive parameters should be controlled at the 10−5 level to accommodate a rotation sensing accuracy of 10−9 rad/s. The leading-order perturbations are suppressed in the case of perfect cylindrical symmetry, even in the presence of anharmonicity and other errors. An experimental measurement of one of the perturbation terms is presented.
Collapse
|
11
|
Chen YJ, Hansen A, Shuker M, Boudot R, Kitching J, Donley EA. Robust inertial sensing with point-source atom interferometry for interferograms spanning a partial period. OPTICS EXPRESS 2020; 28:34516-34529. [PMID: 33182919 DOI: 10.1364/oe.399988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 10/01/2020] [Indexed: 06/11/2023]
Abstract
Point source atom interferometry (PSI) uses the velocity distribution in a cold atom cloud to simultaneously measure one axis of acceleration and two axes of rotation from the spatial distribution of interferometer phase in an expanded cloud of atoms. Previously, the interferometer phase has been found from the phase, orientation, and period of the resulting spatial atomic interference fringe images. For practical applications in inertial sensing and precision measurement, it is important to be able to measure a wide range of system rotation rates, corresponding to interferograms with far less than one full interference fringe to very many fringes. Interferogram analysis techniques based on image processing used previously for PSI are challenging to implement for low rotation rates that generate less than one full interference fringe across the cloud. We introduce a new experimental method that is closely related to optical phase-shifting interferometry that is effective in extracting rotation values from signals consisting of fractional fringes as well as many fringes without prior knowledge of the rotation rate. The method finds the interferometer phase for each pixel in the image from four interferograms, each with a controlled Raman laser phase shift, to reconstruct the underlying atomic interferometer phase map without image processing.
Collapse
|
12
|
Enhanced observation time of magneto-optical traps using micro-machined non-evaporable getter pumps. Sci Rep 2020; 10:16590. [PMID: 33024172 PMCID: PMC7538997 DOI: 10.1038/s41598-020-73605-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 09/15/2020] [Indexed: 11/08/2022] Open
Abstract
We show that micro-machined non-evaporable getter pumps (NEGs) can extend the time over which laser cooled atoms can be produced in a magneto-optical trap (MOT), in the absence of other vacuum pumping mechanisms. In a first study, we incorporate a silicon-glass microfabricated ultra-high vacuum (UHV) cell with silicon etched NEG cavities and alumino-silicate glass (ASG) windows and demonstrate the observation of a repeatedly-loading MOT over a 10 min period with a single laser-activated NEG. In a second study, the capacity of passive pumping with laser activated NEG materials is further investigated in a borosilicate glass-blown cuvette cell containing five NEG tablets. In this cell, the MOT remained visible for over 4 days without any external active pumping system. This MOT observation time exceeds the one obtained in the no-NEG scenario by almost five orders of magnitude. The cell scalability and potential vacuum longevity made possible with NEG materials may enable in the future the development of miniaturized cold-atom instruments.
Collapse
|
13
|
Richardson L, Hines A, Schaffer A, Anderson BP, Guzman F. Quantum hybrid optomechanical inertial sensing. APPLIED OPTICS 2020; 59:G160-G166. [PMID: 32749329 DOI: 10.1364/ao.393060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 05/16/2020] [Indexed: 06/11/2023]
Abstract
We discuss the design of quantum hybrid inertial sensor that combines an optomechanical inertial sensor with the retroreflector of a cold atom interferometer. This sensor fusion approach provides absolute and high-accuracy measurements with cold atom interferometers, while utilizing the optomechanical inertial sensor at frequencies above the repetition rate of the atom interferometer. This improves the overall measurement bandwidth as well as the robustness and field deployment capabilities of these systems. We evaluate which parameters yield an optimal acceleration sensitivity, from which we anticipate a noise floor at nano-g levels from DC to 1 kHz.
Collapse
|