1
|
Filipe MD, de Bock E, Postma EL, Bastian OW, Schellekens PPA, Vriens MR, Witkamp AJ, Richir MC. Robotic nipple-sparing mastectomy complication rate compared to traditional nipple-sparing mastectomy: a systematic review and meta-analysis. J Robot Surg 2021; 16:265-272. [PMID: 34128142 PMCID: PMC8960562 DOI: 10.1007/s11701-021-01265-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Accepted: 06/09/2021] [Indexed: 12/03/2022]
Abstract
Breast cancer is worldwide the most common cause of cancer in women and causes the second most common cancer-related death. Nipple-sparing mastectomy (NSM) is commonly used in therapeutic and prophylactic settings. Furthermore, (preventive) mastectomies are, besides complications, also associated with psychological and cosmetic consequences. Robotic NSM (RNSM) allows for better visualization of the planes and reducing the invasiveness. The aim of this study was to compare the postoperative complication rate of RNSM to NSM. A systematic search was performed on all (R)NSM articles. The primary outcome was determining the overall postoperative complication rate of traditional NSM and RNSM. Secondary outcomes were comparing the specific postoperative complication rates: implant loss, hematoma, (flap)necrosis, infection, and seroma. Forty-nine studies containing 13,886 cases of (R)NSM were included. No statistically significant differences were found regarding postoperative complications (RNSM 3.9%, NSM 7.0%, p = 0.070), postoperative implant loss (RNSM 4.1%, NSM 3.2%, p = 0.523), hematomas (RNSM 4.3%, NSM 2.0%, p = 0.059), necrosis (RNSM 4.3%, NSM 7.4%, p = 0.230), infection (RNSM 8.3%, NSM 4.0%, p = 0.054) or seromas (RNSM 3.0%, NSM 2.0%, p = 0.421). Overall, there are no statistically significant differences in complication rates between NSM and RNSM.
Collapse
Affiliation(s)
- M. D. Filipe
- Department of Surgery, Cancer Centre, University Medical Centre Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - E. de Bock
- Department of Surgery, Cancer Centre, University Medical Centre Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - E. L. Postma
- Department of Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - O. W. Bastian
- Department of Surgery, Cancer Centre, University Medical Centre Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - P. P. A. Schellekens
- Department of Plastic Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - M. R. Vriens
- Department of Surgery, Cancer Centre, University Medical Centre Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - A. J. Witkamp
- Department of Surgery, Cancer Centre, University Medical Centre Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - M. C. Richir
- Department of Surgery, Cancer Centre, University Medical Centre Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| |
Collapse
|
2
|
Zhang C, Li J, Jiang H, Li M. Use of fiberoductoscopy for the management of pathological nipple discharge: ten years follow up of a single center in China. Gland Surg 2020; 9:2035-2043. [PMID: 33447554 PMCID: PMC7804554 DOI: 10.21037/gs-20-738] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 10/29/2020] [Indexed: 11/06/2022]
Abstract
BACKGROUND Pathological nipple discharge (PND) is usually associated with benign intraductal papilloma, which has a higher malignant rate than other benign tumors in most cases. Fiberoductoscopy (FDS) is an alternative possibility in diagnostic and finding lesions in PND patients. Previously, the bloody discharge was presumed to show papilloma or breast cancer. However, as we started using FDS, papilloma or cancer also can be found in the cases with a transparent or yellow discharge. This study investigated the value of FDS for the diagnosis and locating of intraductal lesions in cases with nipple discharge. METHODS A retrospective analysis of 3,696 cases that initially presented with pathologic nipple discharge was performed. There were 4,456 FDSs performed, and the correlations between the FDS findings for distinct types of lesions and the pathological diagnosis were determined. RESULTS Among the 2,816 cases of elevated lesions, FDS confirmed 1,933 cases of intraductal papilloma, 584 cases of intraductal papillomatosis, and 299 cases of intraductal carcinoma. Among the 880 cases of non-elevated lesions, FDS confirmed 380 cases of duct dilation, 350 cases of duct inflammation, 136 cases of duct dilation and inflammation, and 14 cases of ductal carcinoma in situ (DCIS). All patients followed up 3 months to 12 years. There were 241 DCIS in total, and 8 cases had local recurrence, 2 cases had metastasis. Invasive ductal carcinoma, 41 cases, 3 had recurrence and 3 had metastases, and 1 for death. Invasive lobular carcinoma 23 cases, recurrence 2 cases, metastasis 1 case. CONCLUSIONS FDS has a high positive predictive rate and correlates well with the results of the pathological examination. The advantage of FDS is that it can observe the lesions, increasing the detection rate of early stage breast cancer, simple to operate, low cost, and no need for the appointment, appropriate for Chinese conditions.
Collapse
Affiliation(s)
- Chao Zhang
- Breast Cancer Department, Beijing Chaoyang Hospital, Beijing, China
| | - Jie Li
- Breast Cancer Department, Beijing Chaoyang Hospital, Beijing, China
| | - Hongchuan Jiang
- Breast Cancer Department, Beijing Chaoyang Hospital, Beijing, China
| | - Mengxin Li
- Breast Cancer Department, Beijing Chaoyang Hospital, Beijing, China
| |
Collapse
|
3
|
Patient-reported outcomes of ductoscopy procedures for pathologic nipple discharge. Breast Cancer 2020; 28:471-477. [PMID: 33180267 PMCID: PMC7925452 DOI: 10.1007/s12282-020-01184-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 11/02/2020] [Indexed: 01/20/2023]
Abstract
Background Pathologic nipple discharge (PND) is a common complaint often associated with breast cancer. However, when ultrasound and mammography are negative, the chances of malignancy are lower than 5%. Currently, major duct excision and microdochectomy are often recommended to alleviate symptoms and definitely rule out malignancy, but can cause infections and breastfeeding problems. Ductoscopy is a minimally invasive endoscopy technique that allows visualization of the mammary ducts and may not only obviate surgery but also detect malignancy. The aim of this study was to determine quality of life (QOL) after ductoscopy in patients with PND. Materials and methods All PND patients referred for ductoscopy between 2014 and 2015 to our hospital were included. Ductoscopy procedures were performed under local anaesthesia in the outpatient clinic. Patients were asked to fill out questionnaires (Breast-Q, EQ-5D-5L and SF-36) on the day of ductoscopy, and after 2 weeks, 3 and 6 months. Additionally, we performed reliability analysis to determine if these questionnaires were suitable for PND patients. Results Fifty consecutive patients underwent ductoscopy of whom 47 patients participated in this study. One domain of SF-36 (vitality) varied significantly over time. Breast-Q, SF-36 and EQ-5D-5L showed that QOL after ductoscopy for PND was unaffected by ductoscopy. Success of the ductoscopy procedure was a significant predictor for satisfaction with the result domain. Conclusion Ductoscopy is a minimally invasive technique that does not seem to impact QoL of PND patients over time. Breast-Q, SF-36 and EQ-5D-5L seem to be suitable existing QOL tests for PND patients undergoing ductoscopy, whereas SF-36 would require modifications.
Collapse
|
4
|
Waaijer L, Filipe MD, Simons J, van der Pol CC, de Boorder T, van Diest PJ, Witkamp AJ. Detection of breast cancer precursor lesions by autofluorescence ductoscopy. Breast Cancer 2020; 28:119-129. [PMID: 32725533 PMCID: PMC7796885 DOI: 10.1007/s12282-020-01136-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 07/16/2020] [Indexed: 12/26/2022]
Abstract
PURPOSE Autofluorescence is an image enhancement technique used for the detection of cancer precursor lesions in pulmonary and gastrointestinal endoscopy. This study evaluated the feasibility of addition of autofluorescence to ductoscopy for the detection of intraductal breast cancer precursor lesions. METHODS An autofluorescence imaging system, producing real-time computed images combining fluorescence intensities, was coupled to a conventional white light ductoscopy system. Prior to surgery, ductoscopy with white light and autofluorescence was evaluated under general anaesthesia in women scheduled for therapeutic or prophylactic mastectomy. Endoscopic findings in both modes were compared, marked and correlated with histology of the surgical specimen. RESULTS Four breast cancer patients and five high-risk women, with a median age of 47 years (range 23-62) were included. In autofluorescence mode, two intraductal lesions were seen in two breast cancer patients, which had an increase in the red-to-green fluorescence intensity compared with the surrounding tissue. One lesion had initially been missed by white light ductoscopy but was clearly visible in subsequent autofluorescence mode. One endoscopic finding was classified as suspicious by white light, but was negative in autofluorescence mode and showed normal histology. CONCLUSIONS This study demonstrates for the first time the in vivo feasibility of autofluorescence ductoscopy to detect pathologically confirmed breast cancer precursor lesions in both breast cancer patients and high-risk women that were occult under white light.
Collapse
Affiliation(s)
- Laurien Waaijer
- Department of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Mando D Filipe
- Department of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| | - Janine Simons
- Department of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Carmen C van der Pol
- Department of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Tjeerd de Boorder
- Department of Medical Technology and Clinical Physics, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Paul J van Diest
- Department of Pathology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Arjen Joost Witkamp
- Department of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| |
Collapse
|
5
|
Network Meta-analysis for the Diagnostic Approach to Pathologic Nipple Discharge. Clin Breast Cancer 2020; 20:e723-e748. [PMID: 32665191 DOI: 10.1016/j.clbc.2020.05.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 05/27/2020] [Accepted: 05/30/2020] [Indexed: 02/07/2023]
Abstract
Pathologic nipple discharge (PND) is one of the most common breast-related complaints for referral because of its supposed association with breast cancer. The aim of this network meta-analysis (NMA) was to compare the diagnostic efficacy of ultrasound, mammogram, cytology, magnetic resonance imaging (MRI), and ductoscopy in patients with PND, as well as to determine the best diagnostic strategy to assess the risk of malignancy as cause for PND. Cochrane Library, PubMed, and Embase were searched to collect relevant literature from the inception of each of the diagnostic methods until January 27, 2020. The search yielded 1472 original citations, of which 36 studies with 3764 patients were finally included for analysis. Direct and indirect comparisons were performed using an NMA approach to evaluate the combined odd ratios and to determine the surface under the cumulative ranking curves (SUCRA) of the diagnostic value of different imaging methods for the detection of breast cancer in patients with PND. Additionally, a subgroup meta-analysis comparing ductoscopy to MRI when conventional imaging was negative was also performed. According to this NMA, sensitivity for detection of malignancy in patients with PND was highest for MRI (83%), followed by ductoscopy (58%), ultrasound (50%), cytology (38%), and mammogram (22%). Specificity was highest for mammogram (93%) followed by ductoscopy (92%), cytology (90%), MRI (76%), and ultrasound (69%). Diagnostic accuracy was the highest for ductoscopy (88%), followed by cytology (82%), MRI (77%), mammogram (76%), and ultrasound (65%). Subgroup meta-analysis (comparing ductoscopy to MRI when ultrasound and mammogram were negative) showed no significant difference in sensitivity, but ductoscopy was statistically significantly better with regard to specificity and diagnostic accuracy. The results from this NMA indicate that although ultrasound and mammogram may remain low-cost useful first choices for the detection of malignancy in patients with PND, ductoscopy outperforms most imaging techniques (especially MRI) and cytology.
Collapse
|
6
|
de Boorder T, Waaijer L, van Diest PJ, Witkamp AJ. Ex vivo feasibility study of endoscopic intraductal laser ablation of the breast. Lasers Surg Med 2017; 50:137-142. [PMID: 28990682 DOI: 10.1002/lsm.22745] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/14/2017] [Indexed: 12/22/2022]
Abstract
OBJECTIVE To determine the feasibility and safety of breast endoscopic thulium laser ablation for treatment of intraductal neoplasia. STUDY DESIGN Ductoscopy is a minimally invasive endoscopic approach of the milk ducts of the breast via the nipple. Besides diagnosis in women with pathologic nipple discharge (PND), it allows non-invasive removal of intraductal lesions with a stalk like papillomas. Removal, however, is often incomplete and flat lesions cannot be targeted. We therefore developed laser ductoscopy. METHODS Dosimetry of laser ductoscopy was assessed in thirteen mastectomy specimens, applying power settings of 1-5 W with 100-1000 ms pulsed exposure to a 375-μm outer diameter thulium fiber laser. Subsequently histology was obtained from the breast tissue that was treated with the Thulium laser. RESULTS Endoscopic view was maintained during ductoscopic laser ablation at 1-3 W. Increasing power to 4-5 W caused impaired vision due to shrinkage of the main duct around the ductoscope tip. Histology revealed localized ablation of the duct wall. CONCLUSION We show for the first time that laser ductoscopy is technically feasible. The Thulium laser enables a superficial intraductal ablation and is a useful tool for intraductal interventions. An in vivo prospective study is needed to further demonstrate its potential. Lasers Surg. Med. 50:137-142, 2018. © 2017 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Tjeerd de Boorder
- Departments of Medical Technology and Clinical Physics, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Laurien Waaijer
- Departments of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Paul J van Diest
- Departments of Pathology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Arjen J Witkamp
- Departments of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| |
Collapse
|
7
|
Waaijer L, Simons JM, Borel Rinkes IHM, van Diest PJ, Verkooijen HM, Witkamp AJ. Systematic review and meta-analysis of the diagnostic accuracy of ductoscopy in patients with pathological nipple discharge. Br J Surg 2016; 103:632-643. [DOI: 10.1002/bjs.10125] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Revised: 11/07/2015] [Accepted: 01/06/2016] [Indexed: 11/06/2022]
Abstract
Abstract
Background
Invasive surgery remains the standard for diagnosis of pathological nipple discharge (PND). Only a minority of patients with nipple discharge and an unsuspicious finding on conventional breast imaging have cancer. Ductoscopy is a minimally invasive alternative for evaluation of PND. This systematic review and meta-analysis was designed to evaluate the diagnostic accuracy of ductoscopy in patients with PND.
Methods
A systematic search of electronic databases for studies addressing ductoscopy in patients with PND was conducted. Two classification systems were assessed. For DSany, all visualized ductoscopic abnormalities were classified as positive, whereas for DSsusp, only suspicious findings were considered positive. After checking heterogeneity, pooled sensitivity and specificity of DSany and DSsusp were calculated.
Results
The search yielded 4642 original citations, of which 20 studies were included in the review. Malignancy rates varied from 0 to 27 per cent. Twelve studies, including 1994 patients, were eligible for meta-analysis. Pooled sensitivity and specificity of DSany were 94 (95 per cent c.i. 88 to 97) per cent and 47 (44 to 49) per cent respectively. Pooled sensitivity and specificity of DSsusp were 50 (36 to 64) and 83 (81 to 86) per cent respectively. Heterogeneity between studies was moderate to large for sensitivity (DSany: I2 = 17·5 per cent; DSsusp: I2 = 37·9 per cent) and very large for specificity (DSany: I2 = 96·8 per cent; DSsusp: I2 = 92·6 per cent).
Conclusion
Ductoscopy detects about 94 per cent of all underlying malignancies in patients with PND, but does not permit reliable discrimination between malignant and benign findings.
Collapse
Affiliation(s)
- L Waaijer
- Department of Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - J M Simons
- Department of Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - I H M Borel Rinkes
- Department of Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - P J van Diest
- Department of Pathology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - H M Verkooijen
- Imaging Division, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - A J Witkamp
- Department of Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| |
Collapse
|
8
|
Sarica O, Ozturk E, Demirkurek HC, Uluc F. Comparison of ductoscopy, galactography, and imaging modalities for the evaluation of intraductal lesions: a critical review. Breast Care (Basel) 2013; 8:348-54. [PMID: 24415988 PMCID: PMC3862052 DOI: 10.1159/000355833] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Today, in cases of nipple discharge of unclear origin, the abundance of diagnostic procedures - a, diagnostic dilemma' - becomes apparent, because unequivocal indications and a current, standardized examination sequence are presently not available. The diagnostic workup of patients with nipple discharge usually includes the clinical history, physical examination, mammography, ultrasonography, galactography, and nipple discharge cytology, but not ductoscopy. METHODS In this review we analyze and discuss the possible role of ductoscopy in evaluating intraductal pathologies and its combined use with diagnostic imaging modalities. For this purpose, we reviewed and compared the results of the radiological, pathological, and surgical studies independently. CONCLUSIONS Currently, there is no solitary accurate modality to reach our definitive purpose. Being aware of the capability of each diagnostic modality may take us closer to our target. Therefore, adjunct and appropriate use of multiple imaging modalities and ductoscopy is necessary to evaluate patients with nipple discharge.
Collapse
Affiliation(s)
- Ozgur Sarica
- Department of Radiology, Taksim Education and Research Hospital, Istanbul, Turkey
| | - Enis Ozturk
- Department of Radiology, Bakirkoy Education and Research Hospital, Istanbul, Turkey
| | - Huseyin C. Demirkurek
- Department of Nuclear Medicine, Taksim Education and Research Hospital, Istanbul, Turkey
| | - Fatih Uluc
- Department of Radiology, Taksim Education and Research Hospital, Istanbul, Turkey
| |
Collapse
|