1
|
Liu HC, Kijanka P, Urban MW. Two-dimensional (2D) dynamic vibration optical coherence elastography (DV-OCE) for evaluating mechanical properties: a potential application in tissue engineering. BIOMEDICAL OPTICS EXPRESS 2021; 12:1217-1235. [PMID: 33796348 PMCID: PMC7984779 DOI: 10.1364/boe.416661] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 01/22/2021] [Accepted: 01/26/2021] [Indexed: 05/12/2023]
Abstract
Mechanical properties in tissues are an important indicator because they are associated with disease states. One of the well-known excitation sources in optical coherence elastography (OCE) to determine mechanical properties is acoustic radiation force (ARF); however, a complicated focusing alignment cannot be avoided. Another excitation source is a piezoelectric (PZT) stack to obtain strain images via compression, which can affect the intrinsic mechanical properties of tissues in tissue engineering. In this study, we report a new technique called two-dimensional (2D) dynamic vibration OCE (DV-OCE) to evaluate 2D wave velocities without tedious focusing alignment procedures and is a non-contact method with respect to the samples. The three-dimensional (3D) Fourier transform was utilized to transfer the traveling waves (x, y, t) into 3D k-space (kx, ky, f). A spatial 2D wavenumber filter and multi-angle directional filter were employed to decompose the waves with omni-directional components into four individual traveling directions. The 2D local wave velocity algorithm was used to calculate a 2D wave velocity map. Six materials, two homogeneous phantoms with 10 mm thickness, two homogeneous phantoms with 2 mm thickness, one heterogeneous phantom with 2 mm diameter inclusion and an ex vivo porcine kidney, were examined in this study. In addition, the ARF-OCE was used to evaluate wave velocities for comparison. Numerical simulations were performed to validate the proposed 2D dynamic vibration OCE technique. We demonstrate that the experimental results were in a good agreement with the results from ARF-OCE (transient OCE) and numerical simulations. Our proposed 2D dynamic vibration OCE could potentially pave the way for mechanical evaluation in tissue engineering and for laboratory translation with easy-to-setup and contactless advantages.
Collapse
Affiliation(s)
- Hsiao-Chuan Liu
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
| | - Piotr Kijanka
- Department of Robotics and Mechatronics, AGH University of Science and Technology, Al. Mickiewicza 30, Krakow 30-059, Poland
| | - Matthew W. Urban
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
- Department of Physiology and Biomedical Engineering, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
| |
Collapse
|
2
|
Ambekar YS, Singh M, Zhang J, Nair A, Aglyamov SR, Scarcelli G, Larin KV. Multimodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:2041-2051. [PMID: 32341865 PMCID: PMC7173892 DOI: 10.1364/boe.387361] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 02/27/2020] [Accepted: 03/05/2020] [Indexed: 05/03/2023]
Abstract
Assessing the biomechanical properties of the crystalline lens can provide crucial information for diagnosing disease and guiding precision therapeutic interventions. Existing noninvasive methods have been limited to global measurements. Here, we demonstrate the quantitative assessment of the elasticity of crystalline lens with a multimodal optical elastography technique, which combines dynamic wave-based optical coherence elastography (OCE) and Brillouin microscopy to overcome the drawbacks of individual modalities. OCE can provide direct measurements of tissue elasticity rapidly and quantitatively, but it is a challenge to image transparent samples such as the lens because this technique relies on backscattered light. On the other hand, Brillouin microscopy can map the longitudinal modulus with micro-scale resolution in transparent samples. However, the relationship between Brillouin-deduced modulus and Young's modulus is not straightforward and sample dependent. By combining these two techniques, we can calibrate Brillouin measurements with OCE, based on the same sample, allowing us to completely map the Young's modulus of the crystalline lens. The combined system was first validated with tissue-mimicking gelatin phantoms of varying elasticities (N = 9). The OCE data was used to calibrate the Brillouin shift measurements and subsequently map the Young's modulus of the phantoms. After validation, OCE and Brillouin measurements were performed on ex-vivo porcine lenses (N = 6), and the Young's modulus of the lenses was spatially mapped. The results show a strong correlation between Young's moduli measured by OCE and longitudinal moduli measured by Brillouin microscopy. The correlation coefficient R was 0.98 for the phantoms and 0.94 for the lenses, respectively. The mean Young's modulus of the anterior and posterior lens was 1.98 ± 0.74 kPa and 2.93 ± 1.13 kPa, respectively, and the Young's modulus of the lens nucleus was 11.90 ± 2.94 kPa. The results presented in this manuscript open a new way for truly quantitative biomechanical mapping of optically transparent (or low scattering) tissues in 3D.
Collapse
Affiliation(s)
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, Houston, TX 77030, USA
| | - Jitao Zhang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Achuth Nair
- Department of Biomedical Engineering, University of Houston, Houston, TX 77030, USA
| | - Salavat R. Aglyamov
- Department of Mechanical Engineering, University of Houston, Houston, TX 77030, USA
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Kirill V. Larin
- Department of Biomedical Engineering, University of Houston, Houston, TX 77030, USA
- Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, TX 77030, USA
| |
Collapse
|
3
|
Wu C, Aglyamov SR, Han Z, Singh M, Liu CH, Larin KV. Assessing the biomechanical properties of the porcine crystalline lens as a function of intraocular pressure with optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2018; 9:6455-6466. [PMID: 31065442 PMCID: PMC6491010 DOI: 10.1364/boe.9.006455] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 11/11/2018] [Accepted: 11/14/2018] [Indexed: 05/04/2023]
Abstract
In this study, we investigated the relationship between the biomechanical properties of the crystalline lens and intraocular pressure (IOP) using a confocal acoustic radiation force (ARF) and phase-sensitive optical coherence elastography (OCE) system. ARF induced a small displacement at the apex of porcine lenses in situ at various artificially controlled IOPs. Maximum displacement, relaxation rate, and Young's modulus were utilized to assess the stiffness of the crystalline lens. The results showed that the stiffness of the crystalline increased as IOP increased, but the lens stiffening was not as significant as the stiffening of other ocular tissues such as the cornea and the sclera. A mechanical hysteresis in the lens was also observed while cycling IOP, indicating that the viscoelastic response of the lens is crucial to fully understanding its biomechanical properties.
Collapse
Affiliation(s)
- Chen Wu
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Salavat R Aglyamov
- Department of Mechanical Engineering, University of Houston, Houston, TX 77204, USA
- Department of Biomedical Engineering, University of Texas, Austin, TX 78712, USA
| | - Zhaolong Han
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
- School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Chih-Hao Liu
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Kirill V Larin
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
- Interdisciplinary Laboratory of Biophotonics, Tomsk State University, Tomsk, Russia
- Molecular Physiology and Biophysics, Baylor College of Medicine, TX 77584, USA
| |
Collapse
|
4
|
Ang M, Baskaran M, Werkmeister RM, Chua J, Schmidl D, Aranha dos Santos V, Garhöfer G, Mehta JS, Schmetterer L. Anterior segment optical coherence tomography. Prog Retin Eye Res 2018; 66:132-156. [DOI: 10.1016/j.preteyeres.2018.04.002] [Citation(s) in RCA: 216] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 02/20/2018] [Accepted: 04/04/2018] [Indexed: 02/03/2023]
|