1
|
Hao R, Zeng N, Zhang Z, He H, He C, Ma H. Polarization feature fusion and calculation of birefringence dynamics in complex anisotropic media. OPTICS LETTERS 2024; 49:2273-2276. [PMID: 38691697 DOI: 10.1364/ol.515983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/13/2024] [Indexed: 05/03/2024]
Abstract
As a complex anisotropic medium, variation in birefringence within biological tissues is closely associated with numerous physiological behaviors and phenomena. In this Letter, we propose a polarization feature fusion method and corresponding polarimetric parameters, which exhibit excellent performance of capturing the birefringence dynamic variation process in complex anisotropic media. By employing the feature fusion method, we combine and transform polarization basis parameters (PBPs) to derive fused polarization feature parameters (FPPs) with explicit expressions. Subsequently, we conduct Monte Carlo (MC) simulation to demonstrate the effectiveness of the proposed FPPs from two variation dimensions of birefringence direction θ and modulus Δn. Leveraging mathematical modeling and linear transformations, we investigate and abstract their response patterns concerning θ and Δn. Finally, the experiments confirm that the FPPs show superior adaptability and interpretability in characterizing the birefringence dynamic process of turbid media. The findings presented in this study provide new, to the best of our knowledge, methodological insights of information extraction for computational polarimetry in biomedical research.
Collapse
|
2
|
Chen Y, Chu J, Xin B, Qi J. Mechanical stability of polarization signatures in biological tissue characterization. BIOMEDICAL OPTICS EXPRESS 2024; 15:2652-2665. [PMID: 38633097 PMCID: PMC11019670 DOI: 10.1364/boe.518756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 03/19/2024] [Accepted: 03/19/2024] [Indexed: 04/19/2024]
Abstract
Mueller matrix imaging polarimetry (MMIP) is a promising technique for investigating structural abnormalities in pathological diagnosis. The characterization stability of polarization signatures, described by Mueller matrix parameters (MMPs), correlates with the mechanical state of the biological medium. In this study, we developed an MMIP system capable of applying quantitative forces to samples and measuring the resulting polarization signatures. Mechanical stretching experiments were conducted on a mimicking phantom and a tissue sample at different force scales. We analyzed the textural features and data distribution of MMP images and evaluated the force effect on the characterization of MMPs using the structural similarity index. The results demonstrate that changes in the mechanical microenvironment (CMM) can cause textural fluctuations in MMP images, interfering with the stability of polarization signatures. Specifically, parameters of anisotropic orientation, retardance, and optical rotation are the most sensitive to CMM, inducing a dramatic change in the overall image texture, while other parameters (e.g., polarization, diattenuation, and depolarization) exhibit locality in their response to CMM. For some MMPs, CMM can enhance regional textural contrasts. This study elucidates the mechanical stability of polarization signatures in biological tissue characterization and provides a valuable reference for further research toward minimizing CMM influence.
Collapse
Affiliation(s)
- Yongtai Chen
- Research Center for Frontier Fundamental Studies, Zhejiang Lab, Hangzhou 311100, China
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, China
| | - Jinkui Chu
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, China
| | - Benda Xin
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, China
| | - Ji Qi
- Research Center for Frontier Fundamental Studies, Zhejiang Lab, Hangzhou 311100, China
| |
Collapse
|
3
|
Salamaga M, Woźniak WA. Partial Mueller matrix polarimeter using liquid crystal modulators. APPLIED OPTICS 2023; 62:2329-2337. [PMID: 37132872 DOI: 10.1364/ao.479425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A simple partial Mueller polarimeter is described, consisting of two linear polarizers and two liquid crystal variable retarders. The measurement leads to an incomplete Mueller-Scierski matrix, in which the elements from the third row and the third column are simultaneously missing. The proposed procedure for determining information about the birefringent medium from such an incomplete matrix is based on numerical methods and carrying out measurements with the rotated azimuthal sample. Acquired from the obtained results, the missing elements of the Mueller-Scierski matrix are reconstructed. The correctness of the method was verified by numerical simulations and test measurements.
Collapse
|
4
|
Abstract
Traditionally, strain gauge, extensometer, and reflection tracking markers have been used to measure the deformation of materials under loading. However, the anisotropy and inhomogeneity of most biological materials restricted the accessibility of the real strain field. Compared to the video extensometer, digital image correlation has the advantage of providing full-field displacement as well as strain information. In this study, a digital image correlation method (DIC) measurement system was employed for chicken breast bio-tissue deformation measurement. To increase the contrast for better correlation, a mixture of ground black pepper and white sesame was sprayed on the surface of samples. The first step was to correct the distorted image caused by the lens using the inverse distorted calibration method and then the influence of subset size and correlation criteria, sum of squared differences (SSD), and zero-normalized sum of squared differences (ZNSSD) were investigated experimentally for accurate measurement. Test results of the sample was translated along the horizontal direction from 0 mm to 3 mm, with an increment of 0.1 mm and the measurement result was compared, and the displacement set on the translation stage. The result shows that the error is less than 3%, and accurate measurement can be achieved with proper surface preparation, subset size, correlation criterion, and image correction. Detailed examination of the strain values show that the strain εx is proportional to the displacement of crosshead, but the strain εy indicates the viscoelastic behavior of tested bio-tissue. In addition, the tested bio-tissue’s linear birefringence extracted by a Mueller matrix polarimetry is for comparison and is in good agreement. As noted above, the integration of the optical parameter measurement system and the digital image correlation method is proposed in this paper to analyze the relationship between the strain changes and optical parameters of biological tissue, and thus the relative optic-stress coefficient can be significantly characterized if Young’s modulus of biological tissue is known.
Collapse
|
5
|
Polarization-Sensitive Digital Holographic Imaging for Characterization of Microscopic Samples: Recent Advances and Perspectives. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10134520] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Polarization-sensitive digital holographic imaging (PS-DHI) is a recent imaging technique based on interference among several polarized optical beams. PS-DHI allows simultaneous quantitative three-dimensional reconstruction and quantitative evaluation of polarization properties of a given sample with micrometer scale resolution. Since this technique is very fast and does not require labels/markers, it finds application in several fields, from biology to microelectronics and micro-photonics. In this paper, a comprehensive review of the state-of-the-art of PS-DHI techniques, the theoretical principles, and important applications are reported.
Collapse
|
6
|
Zhang S, Jiang H, Gu H, Chen X, Liu S. High-speed Mueller matrix ellipsometer with microsecond temporal resolution. OPTICS EXPRESS 2020; 28:10873-10887. [PMID: 32403609 DOI: 10.1364/oe.389825] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Accepted: 03/22/2020] [Indexed: 06/11/2023]
Abstract
A high-speed Mueller matrix ellipsometer (MME) based on photoelastic modulator (PEM) polarization modulation and division-of-amplitude polarization demodulation has been developed, with which a temporal resolution of 11 µs has been achieved for a Mueller matrix measurement. To ensure the accuracy and stability, a novel approach combining a fast Fourier transform algorithm and Bessel function expansion is proposed for the in-situ calibration of PEM. With the proposed calibration method, the peak retardance and static retardance of the PEM can be calibrated with high accuracy and sensitivity over an ultra large retardance variation range. Both static and dynamic measurement experiments have been carried out to show the high accuracy and stability of the developed MME, which can be expected to pave the way for in-situ and real-time monitoring for rapid reaction processes.
Collapse
|
7
|
Cheng ZJ, Yang Y, Huang HY, Yue QY, Guo CS. Single-shot quantitative birefringence microscopy for imaging birefringence parameters. OPTICS LETTERS 2019; 44:3018-3021. [PMID: 31199370 DOI: 10.1364/ol.44.003018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Accepted: 04/12/2019] [Indexed: 06/09/2023]
Abstract
A method for realizing 2D single-shot measurements of birefringence parameters (including both retardation and optic axis orientation) of anisotropic materials using a simple recording setup and an efficient processing algorithm is proposed. The recording setup can be built simply by inserting a circular polarizer and a polarization beam splitter, respectively, in the object path and reference path of a conventional off-axis holographic imaging system, with no need for other adjustments. An algorithm for quantitatively retrieving the birefringence parameters from one single-shot hologram is proposed and demonstrated, in which a new quantity describing the birefringence, called complex birefringence parameter, is introduced, and a set of formulas used to extract the birefringence parameters is derived. Some experimental results are given for demonstrating the feasibility of the method that reveal that the method may provide another effective approach for investigating the birefringence properties of dynamic anisotropic materials, especially the birefringence induced by ultrafast pulse lasers.
Collapse
|
8
|
Wang Y, Wang J, Meng J, Ding G, Shi Z, Wang R, Zhang X. Detection of non-small cell lung cancer cells based on microfluidic polarization microscopic image analysis. Electrophoresis 2018; 40:1202-1211. [PMID: 30378691 DOI: 10.1002/elps.201800284] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2018] [Revised: 10/05/2018] [Accepted: 10/20/2018] [Indexed: 12/17/2022]
Abstract
In early diagnosis of lung cancer, a polarization microscopy is a powerful tool to obtain the optical information of biological tissues. In this paper, a new microfluidic polarization imaging and analysis method was proposed for the detection and classification of cancer-associated fibroblasts and the two kinds of non-small cell lung cancer cells, A549 and H322. A polarizing microscopy system was constructed based on a commercial microscope to obtain 3*3 Mueller matrix of cells. Based on the Muller matrix decomposition algorithm and analysis in spatial domain and frequency domain, appropriate classification parameters were selected for the characterization of different polarization characteristics of cells. Finally, the logistic regression models based on machine learning were applied to determine optimal feature parameters and classify cells. This method integrated the morphological information of the cells, and the polarization characteristics of the cells in different polarization states. It is for the first time that the polarization microscopic image analysis method has been applied to the detection and classification of non-small cell lung cancer cells. The results show that the presented microfluidic polarization microscopic image analysis method could classify cells effectively. Compared with the Muller matrix measurement and calculation methods, the method proposed in this paper was greatly simplified in both the acquisition of polarized images and the analysis and processing of polarized images.
Collapse
Affiliation(s)
- Yanjuan Wang
- College of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
- Software Institute, Dalian Jiaotong University, Dalian, P. R. China
| | - Junsheng Wang
- College of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Jie Meng
- College of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Gege Ding
- College of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Zhi Shi
- College of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Ruoyu Wang
- Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
| | - Xiaohui Zhang
- College of Environmental and Chemical Engineering, Dalian University, Dalian, P. R. China
| |
Collapse
|
9
|
Flexible polarimetric probe for 3 × 3 Mueller matrix measurements of biological tissue. Sci Rep 2017; 7:11958. [PMID: 28931853 PMCID: PMC5607295 DOI: 10.1038/s41598-017-12099-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 09/04/2017] [Indexed: 12/20/2022] Open
Abstract
Polarimetry is a noninvasive method that uses polarised light to assess biophysical characteristics of tissues. A series of incident polarisation states illuminates a biological sample, and analysis of sample-altered polarisation states enables polarimetric tissue assessment. The resultant information can, for example, help quantitatively differentiate healthy from pathologic tissue. However, most bio-polarimetric assessments are performed using free-space optics with bulky optical components. Extension to flexible fibre-based systems is clinically desirable, but is challenging due to polarisation-altering properties of optical fibres. Here, we propose a flexible fibre-based polarimetric solution, and describe its design, fabrication, calibration, and initial feasibility demonstration in ex vivo tissue. The design is based on a flexible fibre bundle of six multimode optical fibres, each terminated with a distal polariser that ensures pre-determined output polarisation states. The resultant probe enables linear 3 × 3 Mueller matrix characterization of distal tissue. Potential in vivo Mueller matrix polarimetric tissue examinations in various directly-inaccessible body cavities are envisioned.
Collapse
|