1
|
Oliveira LR, Pinheiro MR, Tuchina DK, Timoshina PA, Carvalho MI, Oliveira LM. Light in evaluation of molecular diffusion in tissues: Discrimination of pathologies. Adv Drug Deliv Rev 2024; 212:115420. [PMID: 39096937 DOI: 10.1016/j.addr.2024.115420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 07/30/2024] [Accepted: 07/31/2024] [Indexed: 08/05/2024]
Abstract
The evaluation of the diffusion properties of different molecules in tissues is a subject of great interest in various fields, such as dermatology/cosmetology, clinical medicine, implantology and food preservation. In this review, a discussion of recent studies that used kinetic spectroscopy measurements to evaluate such diffusion properties in various tissues is made. By immersing ex vivo tissues in agents or by topical application of those agents in vivo, their diffusion properties can be evaluated by kinetic collimated transmittance or diffuse reflectance spectroscopy. Using this method, recent studies were able to discriminate the diffusion properties of agents between healthy and diseased tissues, especially in the cases of cancer and diabetes mellitus. In the case of cancer, it was also possible to evaluate an increase of 5% in the mobile water content from the healthy to the cancerous colorectal and kidney tissues. Considering the application of some agents to living organisms or food products to protect them from deterioration during low temperature preservation (cryopreservation), and knowing that such agent inclusion may be reversed, some studies in these fields are also discussed. Considering the broadband application of the optical spectroscopy evaluation of the diffusion properties of agents in tissues and the physiological diagnostic data that such method can acquire, further studies concerning the optimization of fruit sweetness or evaluation of poison diffusion in tissues or antidote application for treatment optimization purposes are indicated as future perspectives.
Collapse
Affiliation(s)
- Luís R Oliveira
- Department of Public and Environmental Health, Polytechnic of Porto - School of Health (ESS), Porto, Portugal
| | - Maria R Pinheiro
- Institute for Systems and Computer Engineering, Technology and Science (INESC TEC), Porto, Portugal
| | - Daria K Tuchina
- Institute of Physics and Science Medical Center, Saratov State University, Saratov, Russian Federation; Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russian Federation
| | - Polina A Timoshina
- Institute of Physics and Science Medical Center, Saratov State University, Saratov, Russian Federation; Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russian Federation; Lomonosov Moscow State University, Moscow, Russian Federation
| | - Maria I Carvalho
- Institute for Systems and Computer Engineering, Technology and Science (INESC TEC), Porto, Portugal; Department of Electrical and Computer Engineering, Porto University - Faculty of Engineering, Porto, Portugal
| | - Luís M Oliveira
- Institute for Systems and Computer Engineering, Technology and Science (INESC TEC), Porto, Portugal; Physics Department, Polytechnic of Porto - School of Engineering (ISEP), Porto, Portugal.
| |
Collapse
|
2
|
Martins IS, Silva HF, Lazareva EN, Chernomyrdin NV, Zaytsev KI, Oliveira LM, Tuchin VV. Measurement of tissue optical properties in a wide spectral range: a review [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:249-298. [PMID: 36698664 PMCID: PMC9841994 DOI: 10.1364/boe.479320] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/29/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
A distinctive feature of this review is a critical analysis of methods and results of measurements of the optical properties of tissues in a wide spectral range from deep UV to terahertz waves. Much attention is paid to measurements of the refractive index of biological tissues and liquids, the knowledge of which is necessary for the effective application of many methods of optical imaging and diagnostics. The optical parameters of healthy and pathological tissues are presented, and the reasons for their differences are discussed, which is important for the discrimination of pathologies and the demarcation of their boundaries. When considering the interaction of terahertz radiation with tissues, the concept of an effective medium is discussed, and relaxation models of the effective optical properties of tissues are presented. Attention is drawn to the manifestation of the scattering properties of tissues in the THz range and the problems of measuring the optical properties of tissues in this range are discussed. In conclusion, a method for the dynamic analysis of the optical properties of tissues under optical clearing using an application of immersion agents is presented. The main mechanisms and technologies of optical clearing, as well as examples of the successful application for differentiation of healthy and pathological tissues, are analyzed.
Collapse
Affiliation(s)
- Inês S. Martins
- Center for Innovation in Engineering and Industrial Technology, ISEP, Porto, Portugal
| | - Hugo F. Silva
- Porto University, School of Engineering, Porto, Portugal
| | - Ekaterina N. Lazareva
- Science Medical Center, Saratov State University, Saratov, Russia
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
| | | | - Kirill I. Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Luís M. Oliveira
- Physics Department, Polytechnic of Porto – School of Engineering (ISEP), Porto, Portugal
- Institute for Systems and Computer Engineering, Technology and Science (INESC TEC), Porto, Portugal
| | - Valery V. Tuchin
- Science Medical Center, Saratov State University, Saratov, Russia
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
| |
Collapse
|
3
|
Cesaro G, Milia M, Baruzzo G, Finco G, Morandini F, Lazzarini A, Alotto P, da Cunha Carvalho de Miranda NF, Trajanoski Z, Finotello F, Di Camillo B. MAST: a hybrid Multi-Agent Spatio-Temporal model of tumor microenvironment informed using a data-driven approach. BIOINFORMATICS ADVANCES 2022; 2:vbac092. [PMID: 36699399 PMCID: PMC9744439 DOI: 10.1093/bioadv/vbac092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 12/03/2022] [Indexed: 12/10/2022]
Abstract
Motivation Recently, several computational modeling approaches, such as agent-based models, have been applied to study the interaction dynamics between immune and tumor cells in human cancer. However, each tumor is characterized by a specific and unique tumor microenvironment, emphasizing the need for specialized and personalized studies of each cancer scenario. Results We present MAST, a hybrid Multi-Agent Spatio-Temporal model which can be informed using a data-driven approach to simulate unique tumor subtypes and tumor-immune dynamics starting from high-throughput sequencing data. It captures essential components of the tumor microenvironment by coupling a discrete agent-based model with a continuous partial differential equations-based model.The application to real data of human colorectal cancer tissue investigating the spatio-temporal evolution and emergent properties of four simulated human colorectal cancer subtypes, along with their agreement with current biological knowledge of tumors and clinical outcome endpoints in a patient cohort, endorse the validity of our approach. Availability and implementation MAST, implemented in Python language, is freely available with an open-source license through GitLab (https://gitlab.com/sysbiobig/mast), and a Docker image is provided to ease its deployment. The submitted software version and test data are available in Zenodo at https://dx.doi.org/10.5281/zenodo.7267745. Supplementary information Supplementary data are available at Bioinformatics Advances online.
Collapse
Affiliation(s)
| | | | - Giacomo Baruzzo
- Department of Information Engineering, University of Padova, 35131 Padova, Italy
| | - Giovanni Finco
- Department of Information Engineering, University of Padova, 35131 Padova, Italy
| | - Francesco Morandini
- Department of Information Engineering, University of Padova, 35131 Padova, Italy
| | - Alessio Lazzarini
- Department of Information Engineering, University of Padova, 35131 Padova, Italy
| | - Piergiorgio Alotto
- Department of Industrial Engineering, University of Padova, 35131 Padova, Italy
| | | | - Zlatko Trajanoski
- Biocenter, Institute of Bioinformatics, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - Francesca Finotello
- Biocenter, Institute of Bioinformatics, Medical University of Innsbruck, 6020 Innsbruck, Austria,Institute of Molecular Biology, University Innsbruck, 6020 Innsbruck, Austria,Digital Science Center (DiSC), University Innsbruck, 6020 Innsbruck, Austria
| | | |
Collapse
|
4
|
Shatova OP, Shegay PV, Zabolotneva AA, Shestopalov AV, Kaprin AD. Lactate: a New Look at the Role of an Evolutionarily Ancient Metabolite. J EVOL BIOCHEM PHYS+ 2022. [DOI: 10.1134/s002209302206028x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
5
|
Jaafar A, Darvin ME, Tuchin VV, Veres M. Confocal Raman Micro-Spectroscopy for Discrimination of Glycerol Diffusivity in Ex Vivo Porcine Dura Mater. Life (Basel) 2022; 12:1534. [PMID: 36294969 PMCID: PMC9605590 DOI: 10.3390/life12101534] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 08/27/2022] [Accepted: 09/26/2022] [Indexed: 11/16/2022] Open
Abstract
Dura mater (DM) is a connective tissue with dense collagen, which is a protective membrane surrounding the human brain. The optical clearing (OC) method was used to make DM more transparent, thereby allowing to increase in-depth investigation by confocal Raman micro-spectroscopy and estimate the diffusivity of 50% glycerol and water migration. Glycerol concentration was obtained, and the diffusion coefficient was calculated, which ranged from 9.6 × 10-6 to 3.0 × 10-5 cm2/s. Collagen-related Raman band intensities were significantly increased for all depths from 50 to 200 µm after treatment. In addition, the changes in water content during OC showed that 50% glycerol induces tissue dehydration. Weakly and strongly bound water types were found to be most concentrated, playing a major role in the glycerol-induced water flux and OC. Results show that OC is an efficient method for controlling the DM optical properties, thereby enhancing the in-depth probing for laser therapy and diagnostics of the brain. DM is a comparable to various collagen-containing tissues and organs, such as sclera of eyes and skin dermis.
Collapse
Affiliation(s)
- Ali Jaafar
- Institute for Solid State Physics and Optics, Wigner Research Center for Physics, H-1525 Budapest, Hungary
- Institute of Physics, University of Szeged, Dom ter 9, H-6720 Szeged, Hungary
- Ministry of Higher Education and Scientific Research, Baghdad 10065, Iraq
| | - Maxim E. Darvin
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venerology and Allergology, Charité Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Valery V. Tuchin
- Science Medical Center, Saratov State University, 83 Astrakhanskaya Str., 410012 Saratov, Russia
- Laboratory of Laser Diagnostics of Technical and Living Systems, Institute of Precision Mechanics and Control, FRC “Saratov Scientific Centre of the Russian Academy of Sciences”, 24 Rabochaya Str., 410028 Saratov, Russia
- A.N. Bach Institute of Biochemistry, FRC “Biotechnology of the Russian Academy of Sciences”, 33-2 Leninsky Prospect, 119071 Moscow, Russia
| | - Miklós Veres
- Institute for Solid State Physics and Optics, Wigner Research Center for Physics, H-1525 Budapest, Hungary
| |
Collapse
|
6
|
Xie Q, Zeng N, Huang Y, Tuchin VV, Ma H. Study on the tissue clearing process using different agents by Mueller matrix microscope. BIOMEDICAL OPTICS EXPRESS 2019; 10:3269-3280. [PMID: 31467778 PMCID: PMC6706038 DOI: 10.1364/boe.10.003269] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 05/23/2019] [Accepted: 06/02/2019] [Indexed: 05/05/2023]
Abstract
In this paper, we monitor the in vitro tissue clearing process of mouse dorsal skin immersed into two types of agents using Mueller matrix microscope. By Mueller matrix polar decomposition, we can see that the major difference between polarization changes due to two kinds of agents is the opposite trend of phase retardance with clearing. For the insight of the connection between different agents with the microstructural and optical changes of cleared tissues, we establish various models to mimic the dynamic process of microphysical features of tissues with clearing time. The mechanisms considered include refractive index matching, collagen shrinkage, more orderly fibers and birefringence variation. We compare the experimental results with simulations based on a single mechanism model and a combined model, respectively, which confirms that an individual possible mechanism cannot explain the polarization phenomena due to clearing. Also by simulations of various clearing models involving two possible mechanisms, we can speculate that formamide and saturated sucrose as agents have respective impacts on tissue features and then cause different polarization changes with clearing. Specifically, collagen shrinkage plus birefringence reduction can better explain the tissue cleared by formamide, and refractive index match plus increased birefringence model is likely to be a proper description of tissue cleared by sucrose. Both simulations and experiments also validate the potential of Mueller matrix microscope as a good tool to understand the interaction between clearing agents and tissues.
Collapse
Affiliation(s)
- Qiaolin Xie
- Tsinghua University, Graduate School at Shenzhen, Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, 2279 Lishui Street, Shenzhen 518055, China
- Tsinghua University, Department of Biomedical Engineering, 1 Tsinghua Yuan, Beijing 100084, China
- These authors contributed equally to this work
| | - Nan Zeng
- Tsinghua University, Graduate School at Shenzhen, Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, 2279 Lishui Street, Shenzhen 518055, China
- These authors contributed equally to this work
| | - Yu Huang
- Tsinghua University, Graduate School at Shenzhen, Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, 2279 Lishui Street, Shenzhen 518055, China
- Tsinghua University, Department of Biomedical Engineering, 1 Tsinghua Yuan, Beijing 100084, China
| | - Valery V. Tuchin
- Saratov State University, 83 Astrakhanskaya Street, Saratov 410012, Russia
- Tomsk State University, 36 Lenin Avenue, Tomsk 634050, Russia
- Institute of Precision Mechanics and Control of RAS, 24 Rabochaya Street, Saratov 410028, Russia
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 33-2 Leninsky prospect, Moscow 119071, Russia
| | - Hui Ma
- Tsinghua University, Graduate School at Shenzhen, Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, 2279 Lishui Street, Shenzhen 518055, China
- Tsinghua University, Department of Physics, 1 Tsinghua Yuan, Beijing 100084, China
- Center for Precision Medicine and Healthcare, Tsinghua-Berkeley Shenzhen Institute, Shenzhen, 518071, China
| |
Collapse
|
7
|
Sdobnov AY, Darvin ME, Schleusener J, Lademann J, Tuchin VV. Hydrogen bound water profiles in the skin influenced by optical clearing molecular agents-Quantitative analysis using confocal Raman microscopy. JOURNAL OF BIOPHOTONICS 2019; 12:e201800283. [PMID: 30565427 DOI: 10.1002/jbio.201800283] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 12/14/2018] [Accepted: 12/17/2018] [Indexed: 05/21/2023]
Abstract
Confocal Raman microscopy has been used to measure depth-dependent profiles of porcine skin ex vivo in the high wavenumber region after application of molecular optical clearing agents (OCAs). Glycerol (70%) and iohexol (100% Omnipaque [300]) water solutions were used as OCAs and topically applied to porcine ear skin for 30 and 60 minutes. Using Gaussian function-based deconvolution, the changes of hydrogen bound water molecule types have been microscopically analyzed down to the depth of 200 μm. Results show that both OCAs induced skin dehydration (reduction of total water), which is 51.3% for glycerol (60 minutes), 33.1% for glycerol (30 minutes), 8.3% for Omnipaque (60 minutes) and 4.4% for Omnipaque (30 minutes), on average for the 40 to 200 μm depths. Among the water types in the skin, the following reduction was observed in concentration of weakly bound (51.1%, 33.2%, 7.5% and 4.6%), strongly bound (50.4%, 33.0%, 7.9% and 3.4%), tightly bound (63.6%, 42.3%, 26.1% and 12.9%) and unbound (55.4%, 28.7%, 10.1% and 5.9%) water types on average for the 40 to 200 μm depths, post application of glycerol (60 minutes), glycerol (30 minutes), Omnipaque (60 minutes) and Omnipaque (30 minutes), respectively. As most concentrated in the skin, weakly and strongly bound water types are preferentially involved in the OCA-induced water flux in the skin, and thus, are responsible for optical clearing efficiency.
Collapse
Affiliation(s)
- Anton Y Sdobnov
- Faculty of Information Technology and Electrical Engineering, University of Oulu, Oulu, Finland
- Department of Optics and Biophotonics, Research-Educational Institute of Optics and Biophotonics, Saratov State University, Saratov, Russia
| | - Maxim E Darvin
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venerology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| | - Johannes Schleusener
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venerology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| | - Jürgen Lademann
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venerology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| | - Valery V Tuchin
- Department of Optics and Biophotonics, Research-Educational Institute of Optics and Biophotonics, Saratov State University, Saratov, Russia
- Laboratory of Laser Diagnostics of Technical and Living Systems, Institute of Precision Mechanics and Control of RAS, Saratov, Russia
- Interdisciplinary Laboratory of Biophotonics, Tomsk State University, Tomsk, Russia
- Laboratory of Molecular Imaging, Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
| |
Collapse
|
8
|
Carneiro I, Carvalho S, Henrique R, Oliveira LM, Tuchin VV. A robust ex vivo method to evaluate the diffusion properties of agents in biological tissues. JOURNAL OF BIOPHOTONICS 2019; 12:e201800333. [PMID: 30585430 DOI: 10.1002/jbio.201800333] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 11/30/2018] [Accepted: 12/23/2018] [Indexed: 06/09/2023]
Abstract
A robust method is presented for evaluating the diffusion properties of chemicals in ex vivo biological tissues. Using this method that relies only on thickness and collimated transmittance measurements, the diffusion properties of glycerol, fructose, polypropylene glycol and water in muscle tissues were evaluated. Amongst other results, the diffusion coefficient of glycerol in colorectal muscle was estimated with a value of 3.3 × 10-7 cm2 /s. Due to the robustness and simplicity of the method, it can be used in other fields of biomedical engineering, namely in organ cryoprotection and food industry.
Collapse
Affiliation(s)
- Isa Carneiro
- Department of Pathology and Cancer Biology, and Epigenetics Group - Research Center, Portuguese Oncology Institute of Porto, Porto, Portugal
| | - Sónia Carvalho
- Department of Pathology and Cancer Biology, and Epigenetics Group - Research Center, Portuguese Oncology Institute of Porto, Porto, Portugal
| | - Rui Henrique
- Department of Pathology and Cancer Biology, and Epigenetics Group - Research Center, Portuguese Oncology Institute of Porto, Porto, Portugal
- Department of Pathology and Molecular Immunology, Institute of Biomedical Sciences Abel Salazar - University of Porto (ICBAS-UP), Porto, Portugal
| | - Luís M Oliveira
- Physics Department - Polytechnic Institute of Porto, School of Engineering, Porto, Portugal
- Centre of Innovation in Engineering and Industrial Technology (CIETI), School of Engineering, Polytechnic of Porto, Porto, Portugal
| | - Valery V Tuchin
- Research-Educational Institute of Optics and Biophotonics, Saratov State University, Saratov, Russian Federation
- Interdisciplinary Laboratory of Biophotonics, Tomsk State University, Tomsk, Russian Federation
- Laboratory of Femtomedicine, ITMO University, Saint-Petersburg, Russian Federation
- Laboratory of Laser Diagnostics of Technical and Living Systems, Institute of Precision Mechanics and Control of the Russian Academy of Sciences, Saratov, Russian Federation
| |
Collapse
|
9
|
Kim JH, Jang MJ, Choi J, Lee E, Song KD, Cho J, Kim KT, Cha HJ, Sun W. Optimizing tissue-clearing conditions based on analysis of the critical factors affecting tissue-clearing procedures. Sci Rep 2018; 8:12815. [PMID: 30143733 PMCID: PMC6109102 DOI: 10.1038/s41598-018-31153-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Accepted: 08/13/2018] [Indexed: 11/13/2022] Open
Abstract
Tissue-clearing techniques have received great attention for volume imaging and for the potential to be applied in optical diagnosis. In principle, tissue clearing is achieved by reducing light scattering through a combination of lipid removal, size change, and matching of the refractive index (RI) between the imaging solution and the tissue. However, the contributions of these major factors in tissue clearing have not been systematically evaluated yet. In this study, we experimentally measured and mathematically calculated the contribution of these factors to the clearing of four organs (brain, liver, kidney, and lung). We found that these factors differentially influence the maximal clearing efficacy of tissues and the diffusivity of materials inside the tissue. We propose that these physical properties of organs can be utilized for the quality control (Q/C) process during tissue clearing, as well as for the monitoring of the pathological changes of tissues.
Collapse
Affiliation(s)
- June Hoan Kim
- Department of Anatomy, Korea University College of Medicine, Seoul, 02841, Republic of Korea
| | - Min Jee Jang
- Department of Anatomy, Korea University College of Medicine, Seoul, 02841, Republic of Korea
| | - Jungyoon Choi
- Department of Anatomy, Korea University College of Medicine, Seoul, 02841, Republic of Korea
| | - Eunsoo Lee
- Department of Anatomy, Korea University College of Medicine, Seoul, 02841, Republic of Korea
| | - Kyung-Deok Song
- Department of Physics, Korea University, Seoul, 02841, Republic of Korea
- Center for Molecular Spectroscopy and Dynamics, Institute for Basic Science (IBS), Seoul, 02841, Republic of Korea
| | - Jaeho Cho
- Department of Radiation Oncology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-752, Republic of Korea
| | - Keun-Tae Kim
- Department of Life Science, Sogang University, 35th Baekbum-ro Mapo-gu, Seoul, 04107, Republic of Korea
| | - Hyuk-Jin Cha
- College of Pharmacy, Department of Pharmacy, Seoul National University, Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
| | - Woong Sun
- Department of Anatomy, Korea University College of Medicine, Seoul, 02841, Republic of Korea.
| |
Collapse
|
10
|
Lee SSY, Bindokas VP, Kron SJ. Multiplex three-dimensional optical mapping of tumor immune microenvironment. Sci Rep 2017; 7:17031. [PMID: 29208908 PMCID: PMC5717053 DOI: 10.1038/s41598-017-16987-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 11/19/2017] [Indexed: 12/15/2022] Open
Abstract
Recent developments in optical tissue clearing and microscopic imaging have advanced three-dimensional (3D) visualization of intact tissues and organs at high resolution. However, to expand applications to oncology, critical limitations of current methods must be addressed. Here we describe transparent tissue tomography (T3) as a tool for rapid, three-dimensional, multiplexed immunofluorescent tumor imaging. Cutting tumors into sub-millimeter macrosections enables simple and rapid immunofluorescence staining, optical clearing, and confocal microscope imaging. Registering and fusing macrosection images yields high resolution 3D maps of multiple tumor microenvironment components and biomarkers throughout a tumor. The 3D maps can be quantitatively evaluated by automated image analysis. As an application of T3, 3D mapping and analysis revealed a heterogeneous distribution of programmed death-ligand 1 (PD-L1) in Her2 transgenic mouse mammary tumors, with high expression limited to tumor cells at the periphery and to CD31+ vascular endothelium in the core. Also, strong spatial correlation between CD45+ immune cell distribution and PD-L1 expression was revealed by T3 analysis of the whole tumors. Our results demonstrate that a tomographic approach offers simple and rapid access to high-resolution three-dimensional maps of the tumor immune microenvironment, offering a new tool to examine tumor heterogeneity.
Collapse
Affiliation(s)
- Steve Seung-Young Lee
- Department of Molecular Genetics and Cell Biology, The University of Chicago, Chicago, IL, USA
- Ludwig Center for Metastasis Research, The University of Chicago, Chicago, IL, USA
| | - Vytautas P Bindokas
- Integrated Light Microscopy Facility, The University of Chicago, Chicago, IL, USA
| | - Stephen J Kron
- Department of Molecular Genetics and Cell Biology, The University of Chicago, Chicago, IL, USA.
- Ludwig Center for Metastasis Research, The University of Chicago, Chicago, IL, USA.
| |
Collapse
|
11
|
Carneiro I, Carvalho S, Henrique R, Oliveira L, Tuchin VV. Simple multimodal optical technique for evaluation of free/bound water and dispersion of human liver tissue. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-10. [PMID: 29210219 DOI: 10.1117/1.jbo.22.12.125002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Accepted: 11/15/2017] [Indexed: 05/22/2023]
Abstract
The optical dispersion and water content of human liver were experimentally studied to estimate the optical dispersions of tissue scatterers and dry matter. Using temporal measurements of collimated transmittance [Tc(t)] of liver samples under treatment at different glycerol concentrations, free water and diffusion coefficient (Dgl) of glycerol in liver were found as 60.0% and 8.2×10-7 cm2/s, respectively. Bound water was calculated as the difference between the reported total water of 74.5% and found free water. The optical dispersion of liver was calculated from the measurements of refractive index (RI) of tissue samples made for different wavelengths between 400 and 1000 nm. Using liver and water optical dispersions at 20°C and the free and total water, the dispersions for liver scatterers and dry matter were calculated. The estimated dispersions present a decreasing behavior with wavelength. The dry matter dispersion shows higher RI values than liver scatterers, as expected. Considering 600 nm, dry matter has an RI of 1.508, whereas scatterers have an RI of 1.444. These dispersions are useful to characterize the RI matching mechanism in optical clearing treatments, provided that [Tc(t)] and thickness measurements are performed during treatment. The knowledge of Dgl is also important for living tissue cryoprotection applications.
Collapse
Affiliation(s)
- Isa Carneiro
- Portuguese Oncology Institute of Porto, Department of Pathology and Cancer Biology and Epigenetics G, Portugal
| | - Sónia Carvalho
- Portuguese Oncology Institute of Porto, Department of Pathology and Cancer Biology and Epigenetics G, Portugal
| | - Rui Henrique
- Portuguese Oncology Institute of Porto, Department of Pathology and Cancer Biology and Epigenetics G, Portugal
- Institute of Biomedical Sciences Abel Salazar-University of Porto, Department of Pathology and Molec, Portugal
| | - Luís Oliveira
- Polytechnic of Porto, School of Engineering, Department of Physics, Porto, Portugal
- Centre of Innovation in Engineering and Industrial Technology, ISEP, Porto, Portugal
| | - Valery V Tuchin
- Saratov State University (National Research University of Russia), Research-Educational Institute of, Russia
- Precision Mechanics and Control Institute of the Russian Academy of Sciences, Laboratory of Laser Di, Russia
- ITMO University, Laboratory of Femtomedicine, St. Petersburg, Russia
| |
Collapse
|
12
|
Swapna MNS, Anitha MJ, Sankararaman SI. Study of drug diffusion rate by laser beam deflection technique. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:68001. [PMID: 28593305 DOI: 10.1117/1.jbo.22.6.068001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Accepted: 05/22/2017] [Indexed: 06/07/2023]
Abstract
Drug administration is an unavoidable part of treatment. When a drug is administered orally or intravenously, it gets absorbed into the blood stream. The rate and efficiency of absorption depend on the route of administration. When a drug is administered through the oral route, it penetrates the epithelial cells of the intestinal mucosa. The diffusion of the drug into the blood stream depends on various parameters, such as concentration, temperature, and the nature of the mucous membrane. The passive diffusion of drugs is found to obey Fick’s law. Water soluble drugs penetrate the cell membrane through aqueous channel or pores. Hence, the study of diffusion of drugs into the water and finally into the blood stream is important. An attempt has been made to study the diffusion of the drug in water as 60% to 80% of human body is water. For the study of drug diffusion in water, a commonly used cough syrup of specific gravity 1.263 is used. It is found that the diffusion rate increases with the concentration of the drug.
Collapse
Affiliation(s)
| | - Madhu J Anitha
- University of Kerala, Department of Optoelectronics, Trivandrum, Kerala, India
| | | |
Collapse
|