1
|
Patel MR, Jacob KC, Parsons AW, Chavez FA, Ribot MA, Munim MA, Vanjani NN, Pawlowski H, Prabhu MC, Singh K. Systematic Review: Applications of Intraoperative Ultrasound in Spinal Surgery. World Neurosurg 2022; 164:e45-e58. [PMID: 35259500 DOI: 10.1016/j.wneu.2022.02.130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 02/28/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND Due to increased practicality and decreased costs and radiation, interest has risen for intraoperative ultrasound (iUS) in spinal surgery applications; however, few studies have provided a robust overview of its use in spinal surgery. We synthesize findings of existing literature on usage of iUS in navigation, pedicle screw placement, and identification of anatomy during spinal interventions. METHODS Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were utilized in this systematic review. Studies were identified through PubMed, Scopus, and Google Scholar databases using the search string. Abstracts mentioning iUS in spine applications were included. Upon full-text review, exclusion criteria were implemented, including outdated studies or those with weak topic relevance or statistical power. Upon elimination of duplicates, multi-reviewer screening for eligibility, and citation search, 44 manuscripts were analyzed. RESULTS Navigation using iUS is safe, effective, and economical. iUS registration accuracy and success is within clinically acceptable limits for image-guided navigation (Table 2). Pedicle screw instrumentation with iUS is precise with a favorable safety profile (Table 2). Anatomical landmarks are reliably identified with iUS, and surgeons are overwhelmingly successful in neural or vascular tissue identification with iUS modalities including standard B mode, doppler, and contrast-enhanced ultrasound (CE-US) (Table 3). iUS use in traumatic reduction of fractures properly identifies anatomical structures, intervertebral disc space, and vasculature (Table 3). CONCLUSION iUS eliminates radiation, decreases costs, and provides sufficient accuracy and reliability in identification of anatomical and neurovascular structures in various spinal surgery settings.
Collapse
Affiliation(s)
- Madhav R Patel
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Kevin C Jacob
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Alexander W Parsons
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Frank A Chavez
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Max A Ribot
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Mohammed A Munim
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Nisheka N Vanjani
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Hanna Pawlowski
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Michael C Prabhu
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Kern Singh
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612.
| |
Collapse
|
2
|
Dorilio J, Utah N, Dowe C, Avrumova F, Alicea D, Brecevich A, Callanan T, Sama A, Lebl DR, Abjornson C, Cammisa FP. Comparing the Efficacy of Radiation Free Machine-Vision Image-Guided Surgery With Traditional 2-Dimensional Fluoroscopy: A Randomized, Single-Center Study. HSS J 2021; 17:274-280. [PMID: 34539267 PMCID: PMC8436349 DOI: 10.1177/15563316211029837] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background: Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. Purpose: We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. Methods: Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. Results: Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups in pedicle screw placement accuracy (2D-fluoroscopy group, 96.6%; 3D-MvIGS group, 94.2%). There were no major complications or cases that required revision surgery. Conclusion: The 3D-MvIGS navigation system performed comparably with 2D-fluoroscopy in terms of pedicle screw placement accuracy and operative time. The 3D-MvIGS showed a significant reduction in radiation exposure to patients. In more complex cases or larger cohorts, the true value of greater anatomical visualization can be elucidated.
Collapse
Affiliation(s)
| | - Nicole Utah
- Hospital for Special Surgery, New York, NY, USA
| | | | | | | | | | | | - Andrew Sama
- Hospital for Special Surgery, New York, NY, USA
| | | | | | | |
Collapse
|